Studio 11 via Forte 6.2 Comparison
I have Mot_OMCR_R19_Children.cxx file. The file a quite large.
Forte 6.2 compiler takes about 9 minutes to compile it, while
Studio 11 compiler is not able to compile this file.
After a long work, it builds totally corrupted object file without any additional diagnostics. Then this file could not be linked. Testing this file with "nm" utility shows, that it is corrupted.
Any suggestion what can be done in this case ?
Message was edited by:
[email protected]
Paul,
thanks for the answer.
I have the following Studio and Solaris. The question is it have all required patches:
tcsh::root>./CC -V
CC: Sun C++ 5.8 2005/10/13
tcsh::root>uname -a
SunOS v240omc10 5.9 Generic_118558-13 sun4u sparc SUNW,Sun-Fire-V240
tcsh::root>
Similar Messages
-
Sun ONE Studio 4 aka Forte: How to set the output path for classes ?
Help !
Beginner's question:
Sun ONE Studio 4 aka Forte:
How to set the output path for classes ?
As default, the class files are created in the same directory as the
sources.
In opposite, both JBuilder and Together support that there is a tree
with the sources and another tree with the classes.
The first answer I got was "not possible with Forte, but just if you write your own "ANT Build script" !
a) Please point me to a ready-to-use ANT script for this purpose, if such is available
b) Is using ANT instead of the MAKE as comfortable ? Besides the separation of sourcecode and classes, I would like to keep everything else to be the same, i.e. I don�t want to edit the ANT file if I enlarge the project by directories or files.
Tia
Sincerely
RolfYou can set S1S's options to place newly created .class files in a specific location.
Identify the compiler that is being used - Open the S1S's Tools/Options window, expand Editing and select Java Sources. Note the Default Compiler value. (If it's one if the Ant options, you use Ant to specify this option, not S1S.)
Open the S1S's Tools/Options window, expand Building/Compiler Types and select the appropriate compiler.
The Properties tab of the compiler has the property Target, which sets the filesystem where the compiler output is directed. If you choose <not set>, the .class files are written to their source directory.
When you set the Target, your change affects all classes that use this compiler.
Very few options can't be set in S1S; the challenge is finding out where they're set! -
Integration of BOBJ Design Studio dashboard via SAP EP
My client is currently piloting the implementation of a BusinessObjects Design Studio dashboard. For maximum flexibility, the Add-on for BI Platform (BIP) has been installed, and we are able to successfully execute the dashboard from the BOBJ LauchPad. Dashboard presents query results from BW.
However, the client now wants to deploy this dashboard to their SAP Enterprise Portal environment. They want the user to be able to access/execute the dashboard from within EP. This is where we have faced several obstacles. Initially, we received a blank screen upon dashboard execution, but this was recently resolved by installing the proper iview template for the BOBJ Design Studio analysis application. (OSS Note 1672422)
Now, when we execute the dashboard via EP, the system presents the BOBJ "hourglass/rainbow circle", but does not complete. I checked the Process Overview in the BW system, and there is no activity taking place during this time.
We are currently at the following release levels:
BW 7.3
Portal 7.4
BOBJ Design Studio 1.4
I would like to hear from someone who has successfully implemented this scenario (Design Studio dashboard, with BIP Add-on, being accessed via SAP EP).
Since we installed the DS Add-On for BIP, or course, we didn't install the DS Add-on for SAP NetWeaver. Do we need to install the NetWeaver Add-on if we want to deploy the dashboards via Portal (even though they are managed/transported within the BI Plaform)?
Any thoughts?
RodHi Ingo:
Just wanted to give you an update on our issue. As you suggested, I created a new Design Studio application, containing only a text box. This application was successfully rendered within the Portal.
Afterward, I started experimenting with other dashboard components, including a crosstab object that was linked to a BW query as a Design Studio datasource. The crosstab was also successfully rendered within the Portal.
I then added a chart to this application and re-executed. While the text box and cross tab were visible, the chart was missing.
After researching further, someone mentioned Google Chrome, so I downloaded it and executed the test dashboard containing text box, crosstab, and chart. It rendered successfully in Portal (via Chrome)!!
Afterward, I then executed my initial dashboard application via Chrome, and it also rendered successfully!
I had previously read several posts regarding IE compatibility with Design Studio, but I was always able to use IE to successfully render Design Studio applications via BOBJ LaunchPad. Therefore, I didn't think I had an issues with DS and IE. However, for us, the issue seems to be between DS, EP, and IE.
Now, we have to deal with an organizational issue of web browsers, but that's a separate challenge.
Thanks to all contributors for your insights.
Rod -
Re: Sending a mail via Forté
Implement SMTP protocol using ExternalConnection object provided by forte.
Hope this helps.
Anand.
Alexis Hassler wrote:
Hi,
=09
We need to send a mail from a Fort=E9 program on NT platforms. Does =
anyone have any ideas or suggestions on how we can do this ?
Any help would be appreciated ! Thanks in advance.
Fran=E7ois LE ROLLAND
OOsphere
<[email protected]>
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>-
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>Hi,
It should depend on where you need to send the mail : on the client or the
server.
On the client, you can use MAPI (there is an ActiveX which works with Forte). On
the server (and the client) you can use an external connection.
Hope this helps,
Daniel Nguyen
Freelance Forte Consultant
Url : http://perso.club-internet.fr/dnguyen/
Alexis Hassler a écrit:
Hi,
=09
We need to send a mail from a Fort=E9 program on NT platforms. Does =
anyone have any ideas or suggestions on how we can do this ?
Any help would be appreciated ! Thanks in advance.
Fran=E7ois LE ROLLAND
OOsphere
<[email protected]>
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>-
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/> -
Windows XP Driver for 17" Studio Display via A1006 Adapter?
No luck searching Google, or this forum. Has Apple released a Win. XP monitor driver for the 17" Studio Display using the ADC-to-DVI (A1006) adapter?
Is there an alternative, non-apple driver?
How can I control monitor brightness on a Win XP box?
TomAh, the Sourceforge project download works perfectly! Note: It's at version 0.4.6., as of my visit to the site today.
Thank you! -
RE: (forte-users) 3J= 3M new to me error
Hi Thomas,
Thanks for your email but I think it will be interesting for Brenda not me.
It is exactly what I have expected from Forte Support: detailed information
about bugs and workarounds. But what I cannot understand is that #53398 was
released without any information about possible reasons for this problem or
suggested workarounds. My first reaction after reading this bugreport was to
open a new case at CallCenter to get more information about it. Please
release more information with your bug reports !
Regards
Zenon Adamek
Information Services
Senior Programmer Analyst
Tel: 905 712-1084 ext. 3628
Fax: 905 712-6709
E-mail: zadamekpurolator.com
-----Original Message-----
From: Thomas Degen - Sun Germany Forte Tools - Bonn
[SMTP:thomas.degensun.com]
Sent: Wednesday, September 27, 2000 9:49 AM
To: Adamek, Zenon
Cc: 'Brenda Cumming'; Forte-userslists.xpedior.com
Subject: RE: (forte-users) 3J=>3M new to me error
Hi Zenon,
bug #53398 is not a bug which will likely get fixed, it's an informational
bugreport.
You might see an errorstack like Brenda has reported (and described in
informational
bugreport #53398) probably when you are doing something illegal that is
possible
via Forte Tool but Forte is not trapping it for performance reasons. Hence
you will see
the error coming from your illegal operation only at runtime, probably
only
while
running interpreted in the Forte IDE, but in worst case it might be even a
segmentation
violation.
Technotes 12448 'Sudden client partition crashes at runtime' and 11225
'Don't reparent
mapped Widgets between UserWindows at runtime' explain this matter . See
attached.
But maybe Brenda is much more experiencing a problem as described by Forte
Technote 11398 'Read Only Workspace Errors using ListViews or ActiveX
control'
that might get easily resolved via setting of FORTE_YIELD_THROTTLE=0.
Good Luck and Best Regards !
BTW: I've logged bug #53398, so I've felt responsible to explain its real
background.
Thomas
Thomas Degen
Sun Microsystems - Forte Tools
Forte CTE & Sustaining Group
Technical Support Germany
tel.:+49.228/91499-50
MailTo:thomas.degensun.com
Technote 11398 Read Only Workspace Errors using ListViews or ActiveX
control
SCENARIO:
Getting some unusual interpreter errors that result in an error stating
that
the workspace has been set to read only. Please see Enclosures for the
two
most common error stacks that have been encountered. The abbreviated
versions of the errors are:
- Can't read record (record size = -1)
- Id in index does not match id in record header in data file
- Recursive deserialization attempted.
- Unknown Mark type in deserialization
- Could not read record (64,74615) from repository data file.
Header
is corrupt.
These errors can be happening in either the development environment when
running from one of the development workshops, or with the deployed
application.
The bug outlined in this Technote may be the culprit if the errors above
are
seen when running a client on Windows NT or Motif and the user interface
incorporates ActiveX controls or ListView/TreeView widgets.
CAUSE:
Basically what is happening is that in rare circumstances Forte may invoke
a
nested copy of the interpreter while the first interpreter has yielded.
This
is not a problem in and of itself, but in the case where the original
interpreter was in the middle of a repository fetch when it yielded, and
the second interpreter needs to fetch code as well, we will get one of the
errors listed above, depending on the exact timing. The reason for the
errors is that the repository code at this level is thread-safe but not
re-entrant. It is protected by a mutex that is already owned by the
current task. Which, given the scenario outlined here, where the two
interpreters are running inside of the same task, results in the nested
interpreter being allowed to change data out from under the first.
While for every fetch one or more calls to WindowSystem.Yield will be made
(this is there to prevent the semblance of system lock-up on Win 3.1,
where
Yield is the only way other applications can be allowed to run), there is
a parameter which controls how often to actually yield, which by default
is
set to one out of every 100 calls. This is the reason the problem is
intermittent--you need a yield to occur during a repository fetch
which starts another interpreter which also needs to fetch code from
disk.
The reason this has only surfaced recently is that the nested interpreter
scenario can only happen in 2 cases that we know of:
- ActiveX controls which respond to events/Windows messages
- Outline fields/ListViews with column(s) mapped to virtual
attributes
In all other normal cases, the yield can process the message (typically a
paint message) without starting another interpreter, so regardless of
whether
the first interpreter yielded during a repository operation or not, there
is
no conflict.
SOLUTION:
The workaround is to prevent yields altogether by setting the
FORTE_YIELD_THROTTLE environment variable equal to 0 in the client's
environment. This should have no detrimental effects since the yield code
is in place solely for Windows 3.1x clients.
ERROR STACK 1
SYSTEM ERROR: Because of a prior error, your workspace was set to
read-only to
prevent the application from attempting to write to the repository. The
repository and work you have saved to the repository are safe. If your
workspace
contains unsaved work, you may use the following procedure to save this
work.
First, export the changed components. Then, shut down and restart this
application and reopen this workspace in read-write mode. Finally, import
the
changed components and save your workspace.
Class: qqrp_RepResourceException
Error #: [1101, 695]
Detected at: qqrp_Session::GetObjectById
Last TOOL statement: method EFWindowController.EFEventLoop
Error Time: Tue Nov 18 15:58:47
Exception occurred (locally) on partition "ConPlus_GUI_cl0_Client",
(partitionId = 7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1,
taskId =
[7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1.23]) in application
"ConPlus_GUI_cl0", pid 147 on node ISD060 in environment EdgeTest.
The remainder of the Error Manager stack is:
SYSTEM ERROR: Internal Error attempting to deserialize element (64,67470)
(fetch
bitmask is 0x20). Your workspace is now read-only to prevent the
application
from attempting to write to the repository. The repository and work you
have
saved to the repository are safe. If your workspace contains unsaved work,
you
may use the following procedure to save this work. First, export the
changed
components. Then, shut down and restart this application and reopen this
workspace in read-write mode. Finally, import the changed components and
save
your workspace.
Class: qqrp_RepResourceException
Error #: [1101, 61]
Detected at: qqrp_LogicalSession::MaterializeObject
Last TOOL statement: method EFTabManagerNew.EFNoteBookHandler
Error Time: Tue Nov 18 15:58:47
Exception occurred (locally) on partition "ConPlus_GUI_cl0_Client",
(partitionId = 7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1,
taskId =
[7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1.23]) in application
"ConPlus_GUI_cl0", pid 147 on node ISD060 in environment EdgeTest.
SYSTEM ERROR: Unknown Mark type in deserialization.
Class: qqsp_ImplementationException
Error #: [1101, 34]
Detected at: qqrp_DeSerializeObject::ProcessHdr
Error Time: Tue Nov 18 15:58:47
Exception occurred (locally) on partition "ConPlus_GUI_cl0_Client",
(partitionId = 7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1,
taskId =
[7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1.23]) in application
"ConPlus_GUI_cl0", pid 147 on node ISD060 in environment EdgeTest.
ERROR STACK 2
SYSTEM ERROR: A serious error has occurred in Repository
(c:\PROGRA~1\CSSPTEST\conplu0). Corrective action may be necessary.
Notify
your repository administrator.
Class: qqsp_ImplementationException
Error #: [1101, 198]
Detected at: qqrp_Repository::Fetch
Last TOOL statement: method
SalesDevelopment_NWC.DEVNotifyofTabSetCurrent
Error Time: Wed Dec 03 10:27:22
Exception occurred (locally) on partition "ConPlus_GUI_cl0_Client",
(partitionId = 769D4310-6B88-11D1-84FD-65BF87C8AA77:0x121:0x1,
taskId =
[769D4310-6B88-11D1-84FD-65BF87C8AA77:0x121:0x1.22]) in application
"ConPlus_GUI_cl0", pid 172 on node ISD42 in environment Edge.
SYSTEM ERROR: Could not read record (64,74615) from repository data file.
Header is corrupt.
Class: qqsp_ImplementationException
Error #: [1106, 612]
Detected at: qqbt_BtreeAccess::FetchDataFileRecord
Error Time: Wed Dec 03 10:27:22
Exception occurred (locally) on partition "ConPlus_GUI_cl0_Client",
(partitionId = 769D4310-6B88-11D1-84FD-65BF87C8AA77:0x121:0x1,
taskId =
[769D4310-6B88-11D1-84FD-65BF87C8AA77:0x121:0x1.22]) in application
"ConPlus_GUI_cl0", pid 172 on node ISD42 in environment Edge.
Technote 11225 Don't reparent mapped Widgets between UserWindows at
runtime
It is sometimes tempting to unparent a widget from one UserWindow and
reparent
it into another at runtime. However, this can cause crashes if the widget
(or
its decendants) are "mapped" to data. Here's why...
Suppose you have two UserWindows, UW1 and UW2. UW1 contains a DataField
(DF1)
which is mapped to a TextData. UW2 contains a RadioList (RL2) which is
mapped to
a scalar Integer. At compile time, every mapped attribute is internally
assigned
a "Map ID" (a small integer) which is used to tie the Widget to its
corresponding attribute. These Map IDs are used by the Widget to look up a
pointer to their data in a "Map" which is maintained by the UserWindow.
Each
UserWindow is assumed be to independent of the others, so there is nothing
wrong
with Widgets in different UserWindows being assigned the same Map IDs.
In
this
case, let's assume that DF1 and RL2 both got assigned the same Map ID of
3. No
problem so far, since each lives in a separate UserWindow with a separate
map.
Now suppose at runtime the application "detaches" or unparents DF1 from
its
UserWindow and reparents it somewhere into UW2. When it comes time for DF1
to
paint itself the Display System it must ask the Runtime System for the
value of
DF1's mapped attribute. To do that it says "give me the value of the
TextData
for DF1. You'll find it in the Map for this UserWindow (UW1), and its Map
ID is
3". When the runtime system goes to do this it expects to find a TextData
in
this "slot" of the map, but instead it picks up the integer which is
mapped to
RL2. At best this leads to bad data being returned; more likely you get a
segfault and a crash.
If DF1 was not a mapped attribute (say, a Rectangle) there would be no
problem
because there is no data mapped to a Rectangle. If instead of moving DF1
you
created a brand new DataField on the fly there would be no problem,
because the
dynamic DataField would not have any Map ID and so couldn't conflict with
any
IDs in UW2.
So how do you solve this problem? This is exactly what Nested Windows are
all
about. While you can't move DF1 into the middle of UW2, you can nest
UW1.
This
works because UW1 brings its map with it, and when you access DF1 it knows
to
look up its value in UW1's map.
UserWindows are intended to be the "unit of compilabilty" that can be
nested
inside other UserWindows. It is dangerous to "transplant" anything from
inside
one UserWindow into another at runtime.
(Note that you can't avoid this problem by cloning DF1 because the MapID
gets
copied along with it, and the clone will fail in the same way.)
Further details explained in related technote 12448 'Sudden client
partition
crashes at runtime.'
Technote 12448 Sudden client partition crashes at runtime
Scenario : You have two UserWindows, A and B. When Window A starts up, it
instantiates an instance of B and reparents some component of B into A's
window
hierarchy.
This is not allowed and almost always leads to an error at best or at
worse a
segmentation fault.
Here's why :
When you compile a UserWindow in Forte, each "mapped attribute" (whether a
form
element or menu element) is assigned an internal ID which represents an
offset into
that UserWindow's table of mapped attributes. This offset is only valid
in the
context of the UserWindow in which it was compiled. If you detach a
FieldWidget or
MenuWidget from one compiled Window ("tmpMenu" for example) and then
parent
into another compiled window ("tmpWindow") the internal ID comes with it.
When Forte tries to make use of that copied widget it uses the ID as an
offset
into tmpWindow's table of mapped attributes. But that copied offset is
meaningless in the context of tmpWindow's table, so you get some kind off
error.
In this case it found that the data type of the variable in the slot
wasn't
what
was expected. But you might even index off the end of the table and get a
segmentation fault.
There is nothing to prevent you from dynamically creating menu items and
adding
them to a window at runtime; that will work fine. Although of course you
can't
access them via mapped attributes, since those can only be created at
compile time.
But you are not allowed to reparent a widget from one compiled UserWindow
into
the hierarchy of another.
More information may be found in technote 11225 'Don't reparent mapped
Widgets
between UserWindows at runtime'.
Possible errorstacks seen at runtime instead of a complete crash or
segmentation
violation while you are illegally reparenting a widget or menuitem between
windows
at runtime:
Map::SetSubjectData: Invalid conversion from map type 0 to subject type 22
SYSTEM ERROR: Bad parameter at location 3 in method
qqrt_MapClassAccess::ProcessSubjectData.
Class: qqsp_Exception
Error #: [1001, 381]
Detected at: qqrt_MapClassAccess::ProcessSubjectData at 3
Error Time: Wed Aug 09 13:03:57
Exception occurred (locally) on partition "testproject_CL0_Client",
(partitionId = D4914A10-36C1-11D4-91B3-419AA33BAA77:0x208:0xd,
taskId =
[D4914A10-36C1-11D4-91B3-419AA33BAA77:0x208:0xd.68]) in application
"FTLaunch_cl0", pid 672 on node ONEWAY in environment Audi3M2Env.
At 13:14 26.09.00 -0400, Adamek, Zenon wrote:
Hi,
It is the unfixed defect 53398. Please contact Forte support.
Zenon
-----Original Message-----
From: Brenda Cumming [SMTP:brenda_cummingtranscanada.com]
Sent: Tuesday, September 26, 2000 1:15 PM
To: Forte User group
Subject: (forte-users) 3J=>3M new to me error
Hi,
We are in the process of going from 3J1 to 3.0.M.2, and I am getting
this error that I am unfamiliar with on a GUI that works fine in 3J.
It
does not happen all the time, and I have been unable to establish the
pattern that kicks it off. Has anyone seen this before?
PS- this error is not occurring in the deployed (non-compiled) app,but
when I am running locally from my workspace.
SYSTEM ERROR: Bad parameter at location 6 in method
qqrt_MapClassAccess::ProcessSubjectData.
Class: qqsp_Exception
Error #: [1001, 381]
Detected at: qqrt_MapClassAccess::ProcessSubjectData at 6
Error Time: Wed Sep 20 14:32:54
Exception occurred (locally) on partition
"ABSDevtStartUp_CL0_Client",
(partitionId = 36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2,
taskId =
[36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2.25]) in
application
"Forte_cl0", pid 93 on node T5621 in environment AbisDMEnv.
SYSTEM ERROR: Can't find scope 20070 for a class.
Class: qqsp_Exception
Error #: [201, 11]
Detected at: qqlo_ClassTableLoadScope at 1
Error Time: Wed Sep 20 14:32:54
Exception occurred (locally) on partition"ABSDevtStartUp_CL0_Client",
(partitionId = 36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2, taskId =
[36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2.25]) in
application
"Forte_cl0", pid 93 on node T5621 in environment AbisDMEnv.
SYSTEM ERROR: Because of a prior error, your workspace was set to
read-only to prevent the application from attempting to write to the repository.
The repository and work you have saved to the repository are safe. If
your
workspace contains unsaved work, you may use the following procedure
to save this work. First, export the changed components. Then, shut down and
restart this application and reopen this workspace in read-write mode.
Finally, import the changed components and save your workspace.
Class: qqrp_RepResourceException
Error #: [1101, 695]
Detected at: qqrp_Session::IsDistributed
Last TOOL statement: method PPMeasWin.
Error Time: Wed Sep 20 14:32:54
Exception occurred (locally) on partition
"ABSDevtStartUp_CL0_Client",
(partitionId = 36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2, taskId =
[36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2.25]) in
application
"Forte_cl0", pid 93 on node T5621 in environment AbisDMEnv.
SYSTEM ERROR: Internal Error attempting to deserialize element
(64,120684) (fetch bitmask is 0x20). Your workspace is now read-onlyto
prevent
the application from attempting to write to the repository. The
repository
and work you have saved to the repository are safe. If your workspace
contains unsaved work, you may use the following procedure to savethis
work.
First, export the changed components. Then, shut down and restart this
application and reopen this workspace in read-write mode. Finally, import the
changed components and save your workspace.
Class: qqrp_RepResourceException
Error #: [1101, 61]
Detected at: qqrp_LogicalSession::MaterializeObject
Error Time: Wed Sep 20 14:32:54
Exception occurred (locally) on partition
"ABSDevtStartUp_CL0_Client",
(partitionId = 36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2, taskId =
[36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2.25]) in
application
"Forte_cl0", pid 93 on node T5621 in environment AbisDMEnv.
SYSTEM ERROR: Recursive Deserialization attempted, Internal Error!
Class: qqsp_UsageException with ReasonCode: SP_ER_INVALIDSTATE
Error #: [301, 231]
Detected at: qqsp_DeSerializeDriver::Run at 1
Error Time: Wed Sep 20 14:32:54
Exception occurred (locally) on partition"ABSDevtStartUp_CL0_Client",
(partitionId = 36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2, taskId =
[36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2.25]) in
application
"Forte_cl0", pid 93 on node T5621 in environment AbisDMEnv.
For the archives, go to: http://lists.xpedior.com/forte-users and use
the login: forte and the password: archive. To unsubscribe, send in anew
email the word: 'Unsubscribe' to:forte-users-requestlists.xpedior.com
For the archives, go to: http://lists.xpedior.com/forte-users and use
the login: forte and the password: archive. To unsubscribe, send in a new
email the word: 'Unsubscribe' to: forte-users-requestlists.xpedior.comHi Thomas,
Thanks for your email but I think it will be interesting for Brenda not me.
It is exactly what I have expected from Forte Support: detailed information
about bugs and workarounds. But what I cannot understand is that #53398 was
released without any information about possible reasons for this problem or
suggested workarounds. My first reaction after reading this bugreport was to
open a new case at CallCenter to get more information about it. Please
release more information with your bug reports !
Regards
Zenon Adamek
Information Services
Senior Programmer Analyst
Tel: 905 712-1084 ext. 3628
Fax: 905 712-6709
E-mail: zadamekpurolator.com
-----Original Message-----
From: Thomas Degen - Sun Germany Forte Tools - Bonn
[SMTP:thomas.degensun.com]
Sent: Wednesday, September 27, 2000 9:49 AM
To: Adamek, Zenon
Cc: 'Brenda Cumming'; Forte-userslists.xpedior.com
Subject: RE: (forte-users) 3J=>3M new to me error
Hi Zenon,
bug #53398 is not a bug which will likely get fixed, it's an informational
bugreport.
You might see an errorstack like Brenda has reported (and described in
informational
bugreport #53398) probably when you are doing something illegal that is
possible
via Forte Tool but Forte is not trapping it for performance reasons. Hence
you will see
the error coming from your illegal operation only at runtime, probably
only
while
running interpreted in the Forte IDE, but in worst case it might be even a
segmentation
violation.
Technotes 12448 'Sudden client partition crashes at runtime' and 11225
'Don't reparent
mapped Widgets between UserWindows at runtime' explain this matter . See
attached.
But maybe Brenda is much more experiencing a problem as described by Forte
Technote 11398 'Read Only Workspace Errors using ListViews or ActiveX
control'
that might get easily resolved via setting of FORTE_YIELD_THROTTLE=0.
Good Luck and Best Regards !
BTW: I've logged bug #53398, so I've felt responsible to explain its real
background.
Thomas
Thomas Degen
Sun Microsystems - Forte Tools
Forte CTE & Sustaining Group
Technical Support Germany
tel.:+49.228/91499-50
MailTo:thomas.degensun.com
Technote 11398 Read Only Workspace Errors using ListViews or ActiveX
control
SCENARIO:
Getting some unusual interpreter errors that result in an error stating
that
the workspace has been set to read only. Please see Enclosures for the
two
most common error stacks that have been encountered. The abbreviated
versions of the errors are:
- Can't read record (record size = -1)
- Id in index does not match id in record header in data file
- Recursive deserialization attempted.
- Unknown Mark type in deserialization
- Could not read record (64,74615) from repository data file.
Header
is corrupt.
These errors can be happening in either the development environment when
running from one of the development workshops, or with the deployed
application.
The bug outlined in this Technote may be the culprit if the errors above
are
seen when running a client on Windows NT or Motif and the user interface
incorporates ActiveX controls or ListView/TreeView widgets.
CAUSE:
Basically what is happening is that in rare circumstances Forte may invoke
a
nested copy of the interpreter while the first interpreter has yielded.
This
is not a problem in and of itself, but in the case where the original
interpreter was in the middle of a repository fetch when it yielded, and
the second interpreter needs to fetch code as well, we will get one of the
errors listed above, depending on the exact timing. The reason for the
errors is that the repository code at this level is thread-safe but not
re-entrant. It is protected by a mutex that is already owned by the
current task. Which, given the scenario outlined here, where the two
interpreters are running inside of the same task, results in the nested
interpreter being allowed to change data out from under the first.
While for every fetch one or more calls to WindowSystem.Yield will be made
(this is there to prevent the semblance of system lock-up on Win 3.1,
where
Yield is the only way other applications can be allowed to run), there is
a parameter which controls how often to actually yield, which by default
is
set to one out of every 100 calls. This is the reason the problem is
intermittent--you need a yield to occur during a repository fetch
which starts another interpreter which also needs to fetch code from
disk.
The reason this has only surfaced recently is that the nested interpreter
scenario can only happen in 2 cases that we know of:
- ActiveX controls which respond to events/Windows messages
- Outline fields/ListViews with column(s) mapped to virtual
attributes
In all other normal cases, the yield can process the message (typically a
paint message) without starting another interpreter, so regardless of
whether
the first interpreter yielded during a repository operation or not, there
is
no conflict.
SOLUTION:
The workaround is to prevent yields altogether by setting the
FORTE_YIELD_THROTTLE environment variable equal to 0 in the client's
environment. This should have no detrimental effects since the yield code
is in place solely for Windows 3.1x clients.
ERROR STACK 1
SYSTEM ERROR: Because of a prior error, your workspace was set to
read-only to
prevent the application from attempting to write to the repository. The
repository and work you have saved to the repository are safe. If your
workspace
contains unsaved work, you may use the following procedure to save this
work.
First, export the changed components. Then, shut down and restart this
application and reopen this workspace in read-write mode. Finally, import
the
changed components and save your workspace.
Class: qqrp_RepResourceException
Error #: [1101, 695]
Detected at: qqrp_Session::GetObjectById
Last TOOL statement: method EFWindowController.EFEventLoop
Error Time: Tue Nov 18 15:58:47
Exception occurred (locally) on partition "ConPlus_GUI_cl0_Client",
(partitionId = 7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1,
taskId =
[7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1.23]) in application
"ConPlus_GUI_cl0", pid 147 on node ISD060 in environment EdgeTest.
The remainder of the Error Manager stack is:
SYSTEM ERROR: Internal Error attempting to deserialize element (64,67470)
(fetch
bitmask is 0x20). Your workspace is now read-only to prevent the
application
from attempting to write to the repository. The repository and work you
have
saved to the repository are safe. If your workspace contains unsaved work,
you
may use the following procedure to save this work. First, export the
changed
components. Then, shut down and restart this application and reopen this
workspace in read-write mode. Finally, import the changed components and
save
your workspace.
Class: qqrp_RepResourceException
Error #: [1101, 61]
Detected at: qqrp_LogicalSession::MaterializeObject
Last TOOL statement: method EFTabManagerNew.EFNoteBookHandler
Error Time: Tue Nov 18 15:58:47
Exception occurred (locally) on partition "ConPlus_GUI_cl0_Client",
(partitionId = 7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1,
taskId =
[7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1.23]) in application
"ConPlus_GUI_cl0", pid 147 on node ISD060 in environment EdgeTest.
SYSTEM ERROR: Unknown Mark type in deserialization.
Class: qqsp_ImplementationException
Error #: [1101, 34]
Detected at: qqrp_DeSerializeObject::ProcessHdr
Error Time: Tue Nov 18 15:58:47
Exception occurred (locally) on partition "ConPlus_GUI_cl0_Client",
(partitionId = 7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1,
taskId =
[7EFAE060-4AFA-11D1-A1C1-1FDC8A99AA77:0x446:0x1.23]) in application
"ConPlus_GUI_cl0", pid 147 on node ISD060 in environment EdgeTest.
ERROR STACK 2
SYSTEM ERROR: A serious error has occurred in Repository
(c:\PROGRA~1\CSSPTEST\conplu0). Corrective action may be necessary.
Notify
your repository administrator.
Class: qqsp_ImplementationException
Error #: [1101, 198]
Detected at: qqrp_Repository::Fetch
Last TOOL statement: method
SalesDevelopment_NWC.DEVNotifyofTabSetCurrent
Error Time: Wed Dec 03 10:27:22
Exception occurred (locally) on partition "ConPlus_GUI_cl0_Client",
(partitionId = 769D4310-6B88-11D1-84FD-65BF87C8AA77:0x121:0x1,
taskId =
[769D4310-6B88-11D1-84FD-65BF87C8AA77:0x121:0x1.22]) in application
"ConPlus_GUI_cl0", pid 172 on node ISD42 in environment Edge.
SYSTEM ERROR: Could not read record (64,74615) from repository data file.
Header is corrupt.
Class: qqsp_ImplementationException
Error #: [1106, 612]
Detected at: qqbt_BtreeAccess::FetchDataFileRecord
Error Time: Wed Dec 03 10:27:22
Exception occurred (locally) on partition "ConPlus_GUI_cl0_Client",
(partitionId = 769D4310-6B88-11D1-84FD-65BF87C8AA77:0x121:0x1,
taskId =
[769D4310-6B88-11D1-84FD-65BF87C8AA77:0x121:0x1.22]) in application
"ConPlus_GUI_cl0", pid 172 on node ISD42 in environment Edge.
Technote 11225 Don't reparent mapped Widgets between UserWindows at
runtime
It is sometimes tempting to unparent a widget from one UserWindow and
reparent
it into another at runtime. However, this can cause crashes if the widget
(or
its decendants) are "mapped" to data. Here's why...
Suppose you have two UserWindows, UW1 and UW2. UW1 contains a DataField
(DF1)
which is mapped to a TextData. UW2 contains a RadioList (RL2) which is
mapped to
a scalar Integer. At compile time, every mapped attribute is internally
assigned
a "Map ID" (a small integer) which is used to tie the Widget to its
corresponding attribute. These Map IDs are used by the Widget to look up a
pointer to their data in a "Map" which is maintained by the UserWindow.
Each
UserWindow is assumed be to independent of the others, so there is nothing
wrong
with Widgets in different UserWindows being assigned the same Map IDs.
In
this
case, let's assume that DF1 and RL2 both got assigned the same Map ID of
3. No
problem so far, since each lives in a separate UserWindow with a separate
map.
Now suppose at runtime the application "detaches" or unparents DF1 from
its
UserWindow and reparents it somewhere into UW2. When it comes time for DF1
to
paint itself the Display System it must ask the Runtime System for the
value of
DF1's mapped attribute. To do that it says "give me the value of the
TextData
for DF1. You'll find it in the Map for this UserWindow (UW1), and its Map
ID is
3". When the runtime system goes to do this it expects to find a TextData
in
this "slot" of the map, but instead it picks up the integer which is
mapped to
RL2. At best this leads to bad data being returned; more likely you get a
segfault and a crash.
If DF1 was not a mapped attribute (say, a Rectangle) there would be no
problem
because there is no data mapped to a Rectangle. If instead of moving DF1
you
created a brand new DataField on the fly there would be no problem,
because the
dynamic DataField would not have any Map ID and so couldn't conflict with
any
IDs in UW2.
So how do you solve this problem? This is exactly what Nested Windows are
all
about. While you can't move DF1 into the middle of UW2, you can nest
UW1.
This
works because UW1 brings its map with it, and when you access DF1 it knows
to
look up its value in UW1's map.
UserWindows are intended to be the "unit of compilabilty" that can be
nested
inside other UserWindows. It is dangerous to "transplant" anything from
inside
one UserWindow into another at runtime.
(Note that you can't avoid this problem by cloning DF1 because the MapID
gets
copied along with it, and the clone will fail in the same way.)
Further details explained in related technote 12448 'Sudden client
partition
crashes at runtime.'
Technote 12448 Sudden client partition crashes at runtime
Scenario : You have two UserWindows, A and B. When Window A starts up, it
instantiates an instance of B and reparents some component of B into A's
window
hierarchy.
This is not allowed and almost always leads to an error at best or at
worse a
segmentation fault.
Here's why :
When you compile a UserWindow in Forte, each "mapped attribute" (whether a
form
element or menu element) is assigned an internal ID which represents an
offset into
that UserWindow's table of mapped attributes. This offset is only valid
in the
context of the UserWindow in which it was compiled. If you detach a
FieldWidget or
MenuWidget from one compiled Window ("tmpMenu" for example) and then
parent
into another compiled window ("tmpWindow") the internal ID comes with it.
When Forte tries to make use of that copied widget it uses the ID as an
offset
into tmpWindow's table of mapped attributes. But that copied offset is
meaningless in the context of tmpWindow's table, so you get some kind off
error.
In this case it found that the data type of the variable in the slot
wasn't
what
was expected. But you might even index off the end of the table and get a
segmentation fault.
There is nothing to prevent you from dynamically creating menu items and
adding
them to a window at runtime; that will work fine. Although of course you
can't
access them via mapped attributes, since those can only be created at
compile time.
But you are not allowed to reparent a widget from one compiled UserWindow
into
the hierarchy of another.
More information may be found in technote 11225 'Don't reparent mapped
Widgets
between UserWindows at runtime'.
Possible errorstacks seen at runtime instead of a complete crash or
segmentation
violation while you are illegally reparenting a widget or menuitem between
windows
at runtime:
Map::SetSubjectData: Invalid conversion from map type 0 to subject type 22
SYSTEM ERROR: Bad parameter at location 3 in method
qqrt_MapClassAccess::ProcessSubjectData.
Class: qqsp_Exception
Error #: [1001, 381]
Detected at: qqrt_MapClassAccess::ProcessSubjectData at 3
Error Time: Wed Aug 09 13:03:57
Exception occurred (locally) on partition "testproject_CL0_Client",
(partitionId = D4914A10-36C1-11D4-91B3-419AA33BAA77:0x208:0xd,
taskId =
[D4914A10-36C1-11D4-91B3-419AA33BAA77:0x208:0xd.68]) in application
"FTLaunch_cl0", pid 672 on node ONEWAY in environment Audi3M2Env.
At 13:14 26.09.00 -0400, Adamek, Zenon wrote:
Hi,
It is the unfixed defect 53398. Please contact Forte support.
Zenon
-----Original Message-----
From: Brenda Cumming [SMTP:brenda_cummingtranscanada.com]
Sent: Tuesday, September 26, 2000 1:15 PM
To: Forte User group
Subject: (forte-users) 3J=>3M new to me error
Hi,
We are in the process of going from 3J1 to 3.0.M.2, and I am getting
this error that I am unfamiliar with on a GUI that works fine in 3J.
It
does not happen all the time, and I have been unable to establish the
pattern that kicks it off. Has anyone seen this before?
PS- this error is not occurring in the deployed (non-compiled) app,but
when I am running locally from my workspace.
SYSTEM ERROR: Bad parameter at location 6 in method
qqrt_MapClassAccess::ProcessSubjectData.
Class: qqsp_Exception
Error #: [1001, 381]
Detected at: qqrt_MapClassAccess::ProcessSubjectData at 6
Error Time: Wed Sep 20 14:32:54
Exception occurred (locally) on partition
"ABSDevtStartUp_CL0_Client",
(partitionId = 36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2,
taskId =
[36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2.25]) in
application
"Forte_cl0", pid 93 on node T5621 in environment AbisDMEnv.
SYSTEM ERROR: Can't find scope 20070 for a class.
Class: qqsp_Exception
Error #: [201, 11]
Detected at: qqlo_ClassTableLoadScope at 1
Error Time: Wed Sep 20 14:32:54
Exception occurred (locally) on partition"ABSDevtStartUp_CL0_Client",
(partitionId = 36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2, taskId =
[36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2.25]) in
application
"Forte_cl0", pid 93 on node T5621 in environment AbisDMEnv.
SYSTEM ERROR: Because of a prior error, your workspace was set to
read-only to prevent the application from attempting to write to the repository.
The repository and work you have saved to the repository are safe. If
your
workspace contains unsaved work, you may use the following procedure
to save this work. First, export the changed components. Then, shut down and
restart this application and reopen this workspace in read-write mode.
Finally, import the changed components and save your workspace.
Class: qqrp_RepResourceException
Error #: [1101, 695]
Detected at: qqrp_Session::IsDistributed
Last TOOL statement: method PPMeasWin.
Error Time: Wed Sep 20 14:32:54
Exception occurred (locally) on partition
"ABSDevtStartUp_CL0_Client",
(partitionId = 36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2, taskId =
[36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2.25]) in
application
"Forte_cl0", pid 93 on node T5621 in environment AbisDMEnv.
SYSTEM ERROR: Internal Error attempting to deserialize element
(64,120684) (fetch bitmask is 0x20). Your workspace is now read-onlyto
prevent
the application from attempting to write to the repository. The
repository
and work you have saved to the repository are safe. If your workspace
contains unsaved work, you may use the following procedure to savethis
work.
First, export the changed components. Then, shut down and restart this
application and reopen this workspace in read-write mode. Finally, import the
changed components and save your workspace.
Class: qqrp_RepResourceException
Error #: [1101, 61]
Detected at: qqrp_LogicalSession::MaterializeObject
Error Time: Wed Sep 20 14:32:54
Exception occurred (locally) on partition
"ABSDevtStartUp_CL0_Client",
(partitionId = 36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2, taskId =
[36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2.25]) in
application
"Forte_cl0", pid 93 on node T5621 in environment AbisDMEnv.
SYSTEM ERROR: Recursive Deserialization attempted, Internal Error!
Class: qqsp_UsageException with ReasonCode: SP_ER_INVALIDSTATE
Error #: [301, 231]
Detected at: qqsp_DeSerializeDriver::Run at 1
Error Time: Wed Sep 20 14:32:54
Exception occurred (locally) on partition"ABSDevtStartUp_CL0_Client",
(partitionId = 36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2, taskId =
[36172000-5DA8-11D4-B1F0-14015EDAAA77:0x2da:0x2.25]) in
application
"Forte_cl0", pid 93 on node T5621 in environment AbisDMEnv.
For the archives, go to: http://lists.xpedior.com/forte-users and use
the login: forte and the password: archive. To unsubscribe, send in anew
email the word: 'Unsubscribe' to:forte-users-requestlists.xpedior.com
For the archives, go to: http://lists.xpedior.com/forte-users and use
the login: forte and the password: archive. To unsubscribe, send in a new
email the word: 'Unsubscribe' to: forte-users-requestlists.xpedior.com -
Questions about Using Lightroom and Print Studio Pro
I want to use Print Studio pro via the lightroom plugin since as I understand it, that is the only way to ensure a 16-bit file is being passed to the printer (on Windows). However, I am a little confused about how the image is being rendered. Is lightroom applying a default output sharpening to the file before handing it off to Print Studio Pro or Does Print Studio Pro manage resolution and Output sharpening based on the media and print size you choose?
So basically I am wondering if there is any output sharpening being applied, and when is it applied. The possibilities I think would be:
Lightroom is applying a default output sharpening when rendering the file to TIF for Print Studio Pro (If this is the case, what setting is being applied and is it possible to change it?)
Print Studio Pro is applying output sharpening based on media type and print size, or applying a generiz amount of sharpening that does not take into account media or size.
No Sharpening is being applied. In this case, I should probably be exporting this file manually with output sharpening applied and then opening in Print Studio Pro
The other question I have is if when using the plugin is the TIF file that is being generated in 16-bit pro-photo to ensure the maximum amount of color data?
Because if Print Studio Pro is not applying sharpening I think it may just be better to print through the lightroom tool even though it renders down to 8-bit because the amount of control I have via the lightroom print module would be far more advantageous than any color data I am losing by printing in 8-bit.
Anyone know the answer to all this?I had similar questions when I first got my Pro-100.
1. You can call up PSP from any module, so I assume it is ignoring print module settings.
2. If I select a Saved Print, which adjusts the print module settings specific to that print, and the open PSP the paper settings in PSP are not what is in LR, supporting the "ignore" conclusion.
3. I ran some test prints using LR to print at three different output sharpening settings (Off, Standard, High) to ensure I could see a difference (I did).
4. I ran four test prints: LR-Standard, XPS driver, LR-Standard regular driver, PSP using standard driver and PSP using XPS driver. I couldn't see any difference between the four prints.
Since LR is such an easy printing process I haven't seen a reason to use PSP.
John Hoffman
Conway, NH
1D Mark IV, Rebel T5i, Pixma PRO-100, MX472 -
RE: DataField, update underlying data via TOOL,Express
John,
does it work if you mix the "CopyfromClipboard" method with the "PlaceValueinDisplayedField" ?
If this is not the correct solution to you problem, could you please specify "where" it does not work ?
Thanks a lot indeed.
Best regards
/Stefano
Stefano POGLIANI Forté Software Consultant
E-Mail : [email protected] Tel : +33.0)450201025
Fax : +33.(0)450200257 Mobile : +33.(6)08431221
Visit the Forté Web Site : http://www.forte.com/
Ducunt fata volentem, nolentem trahunt....
-----Original Message-----
From: John Hodgson [SMTP:[email protected]]
Sent: Wednesday, July 02, 1997 8:39 PM
To: [email protected]
Subject: DataField, update underlying data via TOOL, Express
In TOOL code we PasteText() into a DataField, but the underlying data
object does not get updated until the user interacts with the GUI.
That causes problems if we need to use the underlying data object's
value immediately after the paste. How can we:
force an update of the underlying data object and
ensure that the update goes through before our method call returns,
i.e., ensure that if the update is via Forte events, those events
are handled before returning.
The context is a calendar lookup button that pastes into an adjoining
DataField.
John Hodgson |Descartes Systems Group Inc.|[email protected]
Systems Engineer|120 Randall Drive |http://www.descartes.com
|Waterloo, Ontario |Tel.: 519-746-8110 x250
|CANADA N2V 1C6 |Fax: 519-747-0082Well, I think I have answered my own question, but I will leave it here in case anyone else has the same problem.
So, as far as I have been able to track down, it all went wrong when I was running through the connection wizard.
Under the section titled "Creating the Data Source" is describes how to find your database file and create the appropriate connection string. However, on my version of VS Express 2010 . It offered me a prompts , saying something like, "would you like to
move this database file into the application directory and change the connection string" this sounded very sensible to me, so I said yes.
All proceeded accordingly. And the database file now appeared in the solution explorer.
The app config file said that the connection string was
Data Source=|DataDirectory|\Database1.sdf"
I presumed this would be interpreted correctly by the rest of the app, as it was generated by VS.
But it didn't, what I cannot understand is how no error was generated. And data seemed to pull
into the bound controls.
But I have been testing it for a while now. and it seems that if I manually override the config file with the actual directory where the file exists , then there is not a problem. Data is retained in the file
This is more of a VB.net question, but I couldn't find it in the drop down. I will try and move it there now
Thanks guys for your patience.
p.s. RSingh , the code I posted above did come from the SaveItem_Click event
handler -
Q: How to setting the Sun ONE Studio JDK and Class(and file) Path.
1.I'll use two JDK version.
2.I'll add the Oracle JDBC driver.
3.In my city, I'm didn't find the Sun ONE Studio book.(Forte for Java 4).
need help.
Thank you.Dear javaunter20000,
I'm used the Windows XP Professional(SP1),
I'm use the
Class.forName("oracle.jdbc.driver.OracleDriver").newInstance();
String url="jdbc:oracle:thin:@127.0.0.1:1521:netcob";
String user="***"; String password="***";
Connection conn= DriverManager.getConnection(url,user,password);
connect Orcale, compiler return:
***[34:1] unreported exception java.lang.ClassNotFoundException; must be caught or declared to be thrown
Class.forName("oracle.jdbc.driver.OracleDriver").newInstance();
^
***[34:1] unreported exception java.lang.InstantiationException; must be caught or declared to be thrown
Class.forName("oracle.jdbc.driver.OracleDriver").newInstance();
^ -
Forte WebEnterprise w/ ISAPI - 10055 error
Forte Users,
We have a Forte application that is web-enabled via Forte WebEnterprise and
intermittently we are receiving 10055 error when following a link. After
receiving the error you can either use the back arrow and retry the link or
just hit the refresh button and the page will download. The problem seems
to be intermittent and only seems to happen when the ISAPI Plug-in
(forteisapi.dll) is configured, we have not seen the problem when using the
CGI interface.
I contacted Forte support regarding the error but they are not able to
recreate the error either.
Any help is greatly appreciated!
Please see the following for details on my configuration and environment.
Thanks,
-----Original Message-----
From: MailAgent [mailto:[email protected]]
Sent: Wednesday, November 03, 1999 10:56 AM
To: [email protected]
Subject: Forte Virtual Call Center Case No. -- 56768
Thank you for submitting Case No. 56768. Please save this email as a record
of
your request. If you do not get a response from us within the time period
outlined in our support priority matrix, please email us at
[email protected]
and include the text of this email.
Contact Information
Case No.: 56768
Case Details
FORTE: 3.0.L.3
CONDUCTOR: Not Applicable
EXPRESS: Not Applicable
WEB: WE.1.0.D.1
Client Platform: Windows NT 4.0
Server Platform: SunOS 4.1.3
Database: Not Applicable
Netowork: sockets
Reproducible: Intermittent
Requested Priority: 2 - Medium
Subject:
socket send() to Forte HTTPAccess service object failed. errno=10055
Description:
Runtime Error:Socket Error: socket send() to Forte HTTPAccess service
object
failed. errno=10055
If I refresh or go back and try the link again it usually works.
I am using IIS and have the isapi interface enabled.
Errors:
socket send() to Forte HTTPAccess service object failed. errno=10055
End of message -
Hi,
I am an SAP BIBO consultant. One month before I started using Design Studio 1.2.
Is there any document that will help in BIAL coding???.
Can anyone please show me from the scratch how I can edit the existing standard components in the Design Studio through SDK. I have tried up the addition of Custom components(Colored Box, Google Maps) in Design Studio. That worked fine. But my issue in modifying or editing existing components. How I can import those standard components to Eclipse and how to start editing???
Also one more thing, please show me from where I can download the UI Development Kit (SAP UI5) for Design Studio 1.2. and how to install the same.
I am using,
Eclipse Helios
JDK 1.6
Please help me in this........
Regards,
Arun Krishnan.GHi Arun,
In answer to your questions:
1. You can learn about BIAL scripting through the following resources:
Design Studio Application Designer Guide
Design Studio Tutorials
Getting Started with SAP BusinessObjects Design Studio
Design Studio e-book
2. It is not possible to modify the functionality of the standard Design Studio components via the SDK. You can however modify the appearance of standard components by applying CSS as shown in this tutorial video.
3. You do not need to download the UI5 Development Kit to incorporate UI5 controls into SDK components. To access a UI5 control you need to develop the component using Handler Type "sapui5". The approach is described in Section 6 SDK Extensions Using SAPUI5 Controls of the Developer Guide. You can also download the SDK Templates and Samples which include UI5 examples.
Regards,
Mustafa. -
Importing code from Rose to Forte
Hi there,
I have created a massive model in Rose. Generated code for it all.
Now I want to implement the model in Forte. But all I can do is mount the main directory and nothing more. Forte doesnt understand the EJB class files and deployment descriptors. I cant take the EJBs and work on them - I have to create new ones via Forte. That defeats the purpose of UML modelling.
I tried the same thing in JBuilder which does a better job, but the EJB Designer is buggy so I opted for Forte (4.0).
Are there any instructions for this? Modules? Rose scripts?
thanks and regards,
Kennynothing? no one know anything?
-
What's the best compressor setting to export from FCP to DVD Studio Pro?
I am exporting an 11 minute video from FCP Studio 2 via compressor to go to DVD Studio Pro. It's DV PAL 720 x 576 and I intend the final DVD to be 16:9 so I'll be choosing 16:9 letterbox in DVDStudio Pro.
As my video is only 11 minutes am I losing quality by selecting Best Quality DVD 90 minutes?
And is the way I described above the best way to go about it?You should try the setting as a start, though there are many tweaks you can do if you do not like the results. One of the biggest tweaks is the frame controls (adds more time but can help.)
You should send out to a preset for 16:9 (or make your own setting with aspect ratio of 16:9) then flag the track in DVD SP to 16:9 Letterbox
Some links
http://dvdstepbystep.com/faqs_7.php
http://dvdstepbystep.com/faqs_3.php
And a quick Compressor (2 but same principles for 3) movie here
http://dvdstepbystep.com/qc.php -
Problem: KToolbar builds/runs apps fine, Forte fails
The demo programs that come with the wireless toolkit build and run fine using the KToolbar. But when I try to build and run via Forte, the compiler can't find some of the packages. Why,and how do I fix this?
I installed the software in this order: JDK 1.31 (the latest), then Forte, then the wireless toolkit. And yes, I specified "Integrated (with Forte)" installation of the wireless toolkit.
A remove/reinstall didn't fix the problem.hi,
If you try to compile a midlet using forte then it is throwing an exception that some packages not found.I don't know why.
To overcome this you have to create a midlet suite and update the midlet suite and then execute the suite.
It works fine.
Try excuteing the example suite which comes with toolkit.
Have a look at the doc comes with toolkit. -
I have FCP Studio 1 Academic sitting on FCP 1-4. Need to upgrade to Studio 2 via Studio 2 upgrade ($699). Is a clean install the best route?
danke
Message was edited by: atombombIt is my understanding that academic versions are NOT upgradeable.
A clean install is always the best way to go with FCP/FCS.
-DH
Maybe you are looking for
-
I just bought an ipad2 wifi (no 3G). How can I add my Verizon email account to my ipad? I'd like to send and receive messages from I ipad.
-
I am new at writing vi's and hope you may be able to help. I would like to create a vi that will graph measurements taken from a daq device. I would like to include text data that a user can choose from (example: machine number, test circuit, load ce
-
Flat file conversion-Ignore data in incoming file(Sender)
Hi All, We have a below requirement for sender flat file: In our datatype we have Recordset - Item In file we are getting as Header(Values) Item...... Item.....
-
Which version is good for me to buy? Logic 8 express or Logic studio?
As I said in another post, I did till now all my work in Garageband. I compose mainly classical music for all kind of instruments, I don't do anything with electronic music, nor do I write pop kind of music. What I did in Garageband was setting up my
-
Post Element Text on report items
I am trying to add an image after an item on a multi row report. Was wondering if there was anything similar to the Post Element Text attribute that is available for individual page items?? I admit to being a little lazy in trying to create a custom