Tweak the balance between fan speed and CPU temperature / Dell M6400?

Hi all,
I have a Dell Precision M6400 17" laptop. It runs really well on Arch, but is a bit noisy. It has always been noisy, btw, but I recently noticed that the CPU fan was blowing a lot of air even though the CPU temperature is lower than 70°C. I also have a macbook air, and its CPU runs at 70°C all the time, which seems to be normal. I would like my m6400 to behave similarly, and I'm sure someone here know how to change that
Hardware configuration
* Intel(R) Core(TM)2 Extreme CPU Q9300  @ 2.53GHz
* Quadro FX 2700M (G94M)
* 8Go RAM
* 2 hard drives
lspci output
00:00.0 Host bridge: Intel Corporation 4 Series Chipset DRAM Controller (rev 03)
00:01.0 PCI bridge: Intel Corporation 4 Series Chipset PCI Express Root Port (rev 03)
00:1a.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #4 (rev 02)
00:1a.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #5 (rev 02)
00:1a.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #6 (rev 02)
00:1a.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #2 (rev 02)
00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 02)
00:1c.0 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 1 (rev 02)
00:1c.1 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 2 (rev 02)
00:1c.2 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 3 (rev 02)
00:1c.3 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 4 (rev 02)
00:1c.4 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 5 (rev 02)
00:1c.5 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 6 (rev 02)
00:1d.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #1 (rev 02)
00:1d.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #2 (rev 02)
00:1d.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #3 (rev 02)
00:1d.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #1 (rev 02)
00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev 92)
00:1f.0 ISA bridge: Intel Corporation ICH9M-E LPC Interface Controller (rev 02)
00:1f.2 SATA controller: Intel Corporation 82801IBM/IEM (ICH9M/ICH9M-E) 4 port SATA Controller [AHCI mode] (rev 02)
00:1f.3 SMBus: Intel Corporation 82801I (ICH9 Family) SMBus Controller (rev 02)
01:00.0 VGA compatible controller: NVIDIA Corporation G94M [Quadro FX 2700M] (rev a1)
03:01.0 CardBus bridge: Ricoh Co Ltd RL5c476 II (rev ba)
03:01.1 FireWire (IEEE 1394): Ricoh Co Ltd R5C832 IEEE 1394 Controller (rev 04)
03:01.2 SD Host controller: Ricoh Co Ltd R5C822 SD/SDIO/MMC/MS/MSPro Host Adapter (rev 21)
03:01.3 System peripheral: Ricoh Co Ltd R5C592 Memory Stick Bus Host Adapter (rev 11)
03:01.4 System peripheral: Ricoh Co Ltd xD-Picture Card Controller (rev 11)
09:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5761e Gigabit Ethernet PCIe (rev 10)
0c:00.0 Network controller: Intel Corporation Ultimate N WiFi Link 5300
output of sensors, idle:
acpitz-virtual-0
Adapter: Virtual device
temp1:        +45.5°C  (crit = +107.0°C)
coretemp-isa-0000
Adapter: ISA adapter
Core 0:       +51.0°C  (high = +105.0°C, crit = +105.0°C)
Core 1:       +51.0°C  (high = +105.0°C, crit = +105.0°C)
Core 2:       +48.0°C  (high = +105.0°C, crit = +105.0°C)
Core 3:       +46.0°C  (high = +105.0°C, crit = +105.0°C)
output of sensors when I start interacting (light browsing, mail, chat):
acpitz-virtual-0
Adapter: Virtual device
temp1:        +59.5°C  (crit = +107.0°C)
coretemp-isa-0000
Adapter: ISA adapter
Core 0:       +63.0°C  (high = +105.0°C, crit = +105.0°C)
Core 1:       +63.0°C  (high = +105.0°C, crit = +105.0°C)
Core 2:       +62.0°C  (high = +105.0°C, crit = +105.0°C)
Core 3:       +63.0°C  (high = +105.0°C, crit = +105.0°C)
When I start the laptop, its CPU fan stays at its minimal speed only for 1 or 2 minutes, then increases its rotation speed to a second level. It reaches it maximal speed only under heavy load, when the CPU reaches >80-95°C. I would rather let the CPU run a bit hotter before the fan starts to blow: let's say the fan could enter its intermediary speed between 70°C and 85°C instead of 55-80°C, and blow at is its maximum speed beyond that.
I checked the Fan Speed Control wiki page, but lm-sensors is not able to show me the status of the fans. Any idea ?
Aurel.
PS: the temperature of the GPU is not reported by sensors, and nvidia-settings reports around 60°C. Its dedicated fan is very quiet.

aurelieng wrote:
Hi all,
I have a Dell Precision M6400 17" laptop. It runs really well on Arch, but is a bit noisy. It has always been noisy, btw, but I recently noticed that the CPU fan was blowing a lot of air even though the CPU temperature is lower than 70°C. I also have a macbook air, and its CPU runs at 70°C all the time, which seems to be normal. I would like my m6400 to behave similarly, and I'm sure someone here know how to change that
Hi aurelieng,
I'm in the same situation from at least 1 month ( INTEL CORE 2 EXTREME X9100, 3.06GHz with 8GB ram, one solid state disk 128 GB, and one sata disk 500GB)
My dell M6400 has dual boot: ubuntu and windows7. The fan works a lot and continuosly in both environment and this is the reason because I have doubt that the origin of the problem is in hardware problem?
output of sensors when I start interacting (light browsing, mail, chat):
acpitz-virtual-0
Adapter: Virtual device
temp1:        +41.5°C  (crit = +107.0°C)
coretemp-isa-0000
Adapter: ISA adapter
Core 0:       +41.0°C  (high = +105.0°C, crit = +105.0°C)
Core 1:       +41.0°C  (high = +105.0°C, crit = +105.0°C)
Last edited by ginard (2012-11-16 18:09:19)

Similar Messages

  • Can someone tell me the ti4800se fan speed and cpu temperature...

    I thinks mine is runing a little slow, just under 2000RPM, is this normal? and the temp is 55

    Hi the menu path is as below,
    Logistics>> Material Mgt>>Purchasing>> Purchase Order>>Follow on Function>> MLRP
    Please reward if it helps
    Thanks & regards,
    Indrashish

  • MSI 5900XT-VTD Fan speed and GPU Temperature

    Hello,
    I wonder if someone can tell me how can i know the temperature and fan speed of my MSI Gforce FX 5900 XT-VTD.
    I have installed 3D Turbo Experience (MSI utility) but when i get the window,i'm only able to see the Core and Mem Speed(I can modify them).The fan speed and core temperature are not active.....
    Is it normal ?..

    that card doesnt surport monitoring of temps and fan speed

  • Fan speed and CPU temp

    Hi There,
    I have MBA 13'' Mid 2011.
    I'm little bit concerened about Temp of my CPU which is 96°C, and Fan speed is around 6500rpm.
    I can hear my fan all the time.
    It was not like this always and i'm kind of sure that something is causing this.
    I worked before with lots of apps open (itunes, photoshop, text editor, chrom, mail, parallels..) and fan and temp was not this high.
    Is there way to find out what is causing this high usage?
    Thanks in advanced

    First execute a SMC reset:
    http://support.apple.com/kb/HT3964
    If no change, install istat menus.
    http://bjango.com/mac/istatmenus/
    Open Activity Monitor to ALL PROCESSES and CPU.  Make certain that CPU displays values from high to low.
    Post images of both istat menus and Activity Monitor whe the MBA has heated up.
    Ciao.

  • Fan speed and CPU temp viewing Flash video in Firefox vs. Safari ?

    My MacBook (two months old) running the latest Safari version (3.1) seems to be working unbelievably hard when viewing a flash video. The temps seem to cycle between the high 60s and mid 70s, and the fan blows at max speed constantly. On the other hand, when viewing the same flash videos using Firefox (2.0.0.12), there is only a slight boost in temp (high 50s to low 60s) and the fan speed hardly increases at all.
    Has anyone else noticed this?
    Why would the flash player on one browser be so much more efficient than another (Safari seems to labor, while Firebox breezes along)?

    Thanks!
    Well I guess the code in the Safari browser just wasn't well written. This is true even of the later version of Safari. It does work much better in FireFox, with no crazy heat-up or fan action.
    I've pretty much given up on Safari now on everything by my iPhone and iPt, and only because I have no other choice.

  • Fan speed and computer temperature

    i have 2 questions:
    how fast can macbook´s fan work?
    in between which temperatures should a macbook work with(not environment temperatures, i mean internal temperatures)?

    We have had discussions on this before From those the pre Santa Rosa MacBooks seem that most operate around 60º C in normal operating and the fans usually between 1500 RPM and 3000 RPM. When streaming video or other CPU intensive stuff it will run around 80º C and 6000+ RPM. Some run cooler some run a little hotter.
    Haven't seen any reports yet of the new MacBook temps.

  • Difference in the Balance between FS10N and Customer Balances in Local Curr

    Hi,
    When i am trying to match the Balances between FS10N and Customer Balances in Local Currency for the Period 8, we are getting the difference, The reconcilliaton Account was changed on 30.08.2010.
    Please help Us in tracing the differences between FS10N and Customer Balances in Local Currency.
    What could be the possible reasons for the differences..
    Thanks

    Hi Varshani,
    Please use the program/report SAPF070 to compare or reconcile your AR with GL balances. You can use SAPF071 to correct any inconsistencies. Provided below documentation for these programs.
    SAPF070  - Compare Documents and Account Transaction Figures
    Description
    This program compares debit and credit transaction figures in customer, vendor, and G/L accounts with the debit and credit totals from documents posted in the corresponding posting period (accounting reconciliation). The sales totals are also compared for customer and vendor accounts. There is no separate comparison for special G/L transactions.
    A comparison for G/L accounts can be made in company code currency and in parallel currencies (such as group currency). A comparison for customer and vendor accounts can only be made in company code currency.
    After the program has finished, a message is issued to the user that started the program. This message summarizes the results of the reconciliation.
    Output
    The program compares the totals of an account on a periodic basis. If the debit and credit total differs between account and documents, the account is printed with the debit and credit totals and the difference.
    Differences in G/L accounts are shown per transaction currency. The first line shows the amount in local currency, the second line shows the amounts in transaction currency.
    If a document which falls within the selection range is posted during the program run, the program is terminated since a reliable result can no longer be delivered.
    SAPF071 - Adjust Balances after Comparing Documents/Transaction Figures
    Description
    If a financial accounting comparative analysis (SAPF190) or a comparison of documents and transaction figures (SAPF070) shows that there are differences between documents and transaction figures, you can use this program to make an adjustment. The documents form the basis for this adjustment. The program adjusts the (redundant) transaction figures, which are only totals of amounts from documents.
    Requirements
    All of the following listed requirements must be fulfilled:
    1. A financial accounting comparative analysis (SAPF190) or a comparison of documents and transaction figures (SAPF070) must be made, and differences must be found between documents and transaction figures.
    2. There must not be any inconsistent documents found. These are listed in both SAPF070 and SAPF190 as well as in this program.
    3. There cannot be any problems in the other modules. Caution: You have to check this yourself. Financial Accounting may be correct but the other modules may not be, and this will adversely affect the program run.
    4. You can only make the adjustment in the ledgers which are compared by program SAPF070. This is ledger 00 or a user-defined ledger for all parallel local currencies except the group currency. (The program displays these ledgers). You have to adjust any additional ledgers as well as average balance ledgers yourself.
    5. No documents during the period in which you are adjusting transaction figures can be archived. Caution: You must ensure that these documents are not archived by establishing appropriate organizational rules and procedures.
    Only use this program after consulting with SAP or after checking the prerequisites thoroughly.
    You should adjust all differences together for a single company code. By setting the program parameters you can limit the adjustment to G/L currency types or to balances in subledgers.
    It is advisable to execute a test run first, which will list any differences that are found.
    Further notes - Authorizations
    Repair program authorization group (F_005)
    Company code authorization         (F_BKPF_BUK)
    Thanks
    Venkata Ganesh Perumalla
    Edited by: Venkata Ganesh Perumalla on Sep 28, 2010 1:30 PM

  • What's the Relation Between General Ledger and Customer Balances Extractors

    Hi SAP Gurus,
                        Anybody explain the relationship between General_Ledger, Accounts_Payable and Accounts_Receivable Data Extractors ?

    Hi,
    Relationship in what sense?
    All are timestamp based delta datasources, with After image delta.
    *Settings for them are controlled centrally in same BWOM tables. http://help.sap.com/saphelp_bw33/helpdata/en/af/16533bbb15b762e10000000a114084/content.htm
    *In a way AP & AR data are subset of GL data (as documents are posted to GL accounts). In simple, all Document items with Vendor or Customer linked are fetched in AP & AR.
    But extractors pick the data from indexed BSIK/BSAK and BSID/BSAD tables respectively and not from BSEG table (GL Line Items).

  • [Solved] lm-sensors fan speeds and voltage.

    After installing lm-sensors and running sensors-detect I have the following readings from sensors;
    ~$ sensors
    acpitz-virtual-0
    Adapter: Virtual device
    temp1: +42.0°C (crit = +80.0°C)
    coretemp-isa-0000
    Adapter: ISA adapter
    Core 0: +47.0°C (high = +78.0°C, crit = +100.0°C)
    coretemp-isa-0001
    Adapter: ISA adapter
    Core 1: +42.0°C (high = +78.0°C, crit = +100.0°C)
    I am sure in the recent past I was able to retrieve fan speed and voltage readings from this machine;
    |Abit FP-IN9 SLI | Intel(R) Core(TM)2 Duo CPU [email protected] | GeForce 9800 GT |
    I suspect this is something that I am doing wrong (or is it a kernel issue??) as I have the same problem on a similar machine running Ubuntu 10.04.
    Any ideas appreciated.
    Last edited by ancleessen4 (2010-03-09 08:31:15)

    Hi graysky,
    You were spot on!
    I followed the instructions in the wiki article to add
    acpi_enforce_resources=lax
    to /boot/grub/menu.lst
    Reboot...
    Voila!
    [neil@archbox ~]$ sensors
    acpitz-virtual-0
    Adapter: Virtual device
    temp1: +30.0°C (crit = +80.0°C)
    coretemp-isa-0000
    Adapter: ISA adapter
    Core 0: +36.0°C (high = +78.0°C, crit = +100.0°C)
    coretemp-isa-0001
    Adapter: ISA adapter
    Core 1: +34.0°C (high = +78.0°C, crit = +100.0°C)
    w83627dhg-isa-0290
    Adapter: ISA adapter
    Vcore: +1.12 V (min = +0.00 V, max = +1.74 V)
    in1: +0.91 V (min = +0.51 V, max = +0.21 V) ALARM
    AVCC: +3.30 V (min = +2.98 V, max = +3.63 V)
    VCC: +3.30 V (min = +2.98 V, max = +3.63 V)
    in4: +1.10 V (min = +0.00 V, max = +0.14 V) ALARM
    in5: +1.20 V (min = +0.13 V, max = +0.00 V) ALARM
    in6: +1.58 V (min = +0.02 V, max = +0.00 V) ALARM
    3VSB: +3.23 V (min = +2.98 V, max = +3.63 V)
    Vbat: +3.01 V (min = +2.70 V, max = +3.30 V)
    fan1: 0 RPM (min = 340 RPM, div = 128) ALARM
    fan2: 811 RPM (min = 332 RPM, div = 16)
    fan3: 0 RPM (min = 340 RPM, div = 128) ALARM
    fan4: 0 RPM (min = 340 RPM, div = 128) ALARM
    fan5: 0 RPM (min = 527 RPM, div = 128) ALARM
    temp1: +28.0°C (high = +72.0°C, hyst = +0.0°C) sensor = thermistor
    temp2: +29.0°C (high = +70.0°C, hyst = +65.0°C) sensor = diode
    temp3: +38.5°C (high = +70.0°C, hyst = +65.0°C) sensor = thermistor
    cpu0_vid: +0.000 V
    [neil@archbox ~]$
    :D

  • IMac (early 2009), 3.06 GHz, ATI 4850 - fan speed and temperature questions

    Well, so I downloaded and installed Temperature Monitor and iMac Fan Control - mainly for observational purposes and not for toying around with the fan speeds and I've got some questions. Mind you, I haven't tampered at all with the fan speed settings, just installed Fan Control. Here are my readings (while browsing the internet with Safari and doing a chat via iChat):
    Fan Speeds:
    CPU fan (desired) 1300 RPM / (current) 1530 RPM
    HD fan (desired) 2100 RPM / (current) 2099 RPM
    DVD fan (desired) 1300 / 1298 RPM
    Temperatures:
    CPU Heatsink: 92°F
    Internal HD: 108°F
    Internal DVD: 95°F
    GPU Heatsink: 107°F
    Are these, under the circumstances, normal readings?
    Thanks in advance for your replies.

    Your welcome and no problem. I would say only the Apple engineers can tell you why the fans are set to those speeds however my best guess is the obvious they found those speeds the closest to keeping the temps at an optimum operating temperature. I found when I'm doing graphics intensive work my machine heats up but quickly cools down when I'm done.

  • Fan Speeds, and Mirror Raid with New Internal Hard Drive

    Regards,
    I recently installed and formatted a new hard drive in my PowerMac dual 2.3 ghz computer and I have a few questions.
    1. Now that there are two hard drives do I need to do anything to ensure that the fan on my computer can keep them cool? I think the fans I have in the hard drive bay is enough, but I do not know if they will automatically set themselves to run properly. I can monitor the fan speeds and temp from iStat pro, but do not remember what level the temperature was before installing the new one.
    2. Given that my new drive is a SeaDisc hard drive and the older one is a Western Digital, will this cause any problems in creating a mirrored RAID. I believe that both are 7200rpm drives, and my second hard drive is a little larger (I will just have unused space after making the RAID). I am concerned with the fact that these two drives are from two different manufactures. Will this cause problems or drastically slow down the reading and writing of data? Has anyone else experienced problems in making a mirrored RAID from two hard drives that are not exact matches, and even come from different manufacturers?
    Any advice will help.
    Thanks
    earpshmael

    Hi earpshmael;
    Generally when creating RAID arrays the more similar the drive the less problems you tend to have.
    The real question is exactly why do you want or need RAID?
    I think so many people seem to think that RAID will solve all of their problem. I hate to tell you the bad news but it will not.
    Generally there are to varieties of RAID available using the software RAID built into OS X which are 0 and 1. RAID 0 or stripling is generally for moving large file rapidly for applications like HD video. It usually doesn't help the OS. RAID 1 or mirroring is for protection from drive failure. It is not a valid backup solution.
    Allan

  • HT1463 what is the difference between intel inside and intel core

    What is the difference between intel inside and intel core?

    Those two terms are not directly related.  "Intel Inside" is a marketing phrase that just means that the computer that displays that phrase in advertisements has an Intel CPU inside, as opposed to an AMD processor, for instance.  That's all.  Intel core is not precisely a phrase I've seen; but it would simply refer to the central processing area (the "Core") inside an Intel processor.
    Hope this helps

  • What is the difference between quarterly patches and patch sets

    Hello,
    What is the difference between quarterly patches and patch sets?
    Should we always apply the latest quarterly pathches?
    Is it better to apply to the latest patch set if one can afford?

    The quarterly patch sets are generally security fixes, or Critical Patch Updates (CPU). Oracle strongly recommends that the CPU patches are applied. CPU and quarterly patches do not change the release/version of the database.
    The patch sets contain bug fixes and do change the release/version of the database.
    As with all patches you should test them on a test database before deploying in production. If you have vendor supported applications you should contact your vendor before applying any patchsets.

  • Whats the different between iphone 5s and 5c

    whats the different between iphone 5s and 5c

    Primary differences are:
    Aperture, flash, stabilisation and shutter speed of the camera.
    Processor type and the inclusion of a 'co-processor' for movement sensors.
    Materials used for the frame and outer shell.

  • What is the differences between Transparent,Pooled and Cluster tables?

    Hello all,
    What is Pool table?What is the differences between Transparent,Pooled and Cluster tables?
    Regards!
    Purna

    Transparent table:
    Tables can be defined independently of the database in the ABAP Dictionary. The fields of the table are defined together with their (database-independent) data types and lengths.
    A table definition in the ABAP Dictionary has the following components:
    Table fields: The field names and the data types of the fields contained in the table are defined here.
    Foreign keys: The foreign keys define the relationships between this table and other tables.
    Technical settings: The technical settings define how the table is created on the database.
    Indexes: Indexes can be defined for the table to speed up data selection from the table.
    There are three categories of database tables in the ABAP Dictionary.
    A physical table definition is created in the database for the table definition stored in the ABAP Dictionary for transparent tables when the table is activated. The table definition is translated from the ABAP Dictionary to a definition of the particular database.
    On the other hand, pooled tables and cluster tables are not created in the database. The data of these tables is stored in the corresponding table pool or table cluster. It is not necessary to create indexes and technical settings for pooled and cluster tables.
    Pooled table
    Pooled tables can be used to store control data (e.g. screen sequences, program parameters or temporary data). Several pooled tables can be combined to form a table pool. The table pool corresponds to a physical table on the database in which all the records of the allocated pooled tables are stored.
    Cluster table
    Cluster tables contain continuous text, for example, documentation. Several cluster tables can be combined to form a table cluster. Several logical lines of different tables are combined to form a physical record in this table type. This permits object-by-object storage or object-by-object access. In order to combine tables in clusters, at least parts of the keys must agree. Several cluster tables are stored in one corresponding table on the database.
    Regds,
    Manohar

Maybe you are looking for

  • Change the colour of text

    Dear expert, Can we change the text colour of work center description ( field name: STEXT)? Best Regard pauline

  • How to find a jar file a class is in

    Given a class file, I would like to find out in which jar file it exists.

  • Ignore empty rows

    I have the following table structure AccountTable ...accountID ...RegionID ...CategoryID ...subtypeID CategoryTable ...CategoryID ...accountID RegionTable ...RegionID ...accountID SubtypeTable ...SubtypeID ...accountID I want to form a query which wi

  • BAPI for Partial Confirmation CO11N

    Dear Gurus, REG : BAPI How to get the actual activites for partial confirmation of qty we have tried some bapis like for getting activites we have used bapi_prodordconf_get_tt_prop but in this bapi it is calculating total qty i.e, order qty not for t

  • HT4623 transfer to ipod touch