VISA: Communicate​ion with "imar sensor " via serial port[

Hello
I have problem in communication. I have one sensor imar sensor that can be easily communicate in Hyperlink but if I send same command for example "show conf" it doesn't responses It is connected with rs232 in com port 1.  it will be nice if you give me some suggestion thanking you
regards
Solved!
Go to Solution.

Yeah I can't open that (needs to be 2010 or earlier - see my first post)
Is 57600 baud rate the one specified in the manual for your device? This needs to be absolutely correct for the serial communications to work properly.
"If anyone needs me, I'll be in the Angry Dome!"

Similar Messages

  • Communicat​e with LIN device via RS232

    Hi,
    We have a project to communicate with a card containing the LIN bus. I seek a solution to communicate directly with the card via the RS232 port. I think use an rs232 adapter and a rs232-LIN transceiver directly to the card. The links below containinformation of material:
    http://www.mikroe.com/eng/downloads/get/1276/max23​2_manual_v100.pdf
    http://www.mikroe.com/eng/downloads/get/1507/lin_m​anual_v100.pdf
    I want to know if anyone has used this solution before. Do you think this is feasible.Thus, the problem is that Labwindows allows easy implementation of code ofcommunication with the card (functions, examples ...).
    Thank you for your opinion about this solution.

    Hello,
    Sorry for the delay. Can you describe me your solution. I thought of another alternative. Can I communicate directly using the rs232 port, a LIN  transceiver and a power adapter (rs232 to TTL). Can you tell me what library I should use because I do not know really what is the principle.
    Many thanks

  • How to transfer file from PC to PC via serial port using labview

    I need to transfer files(.txt, .doc, .xls) from PC to PC via serial port using LabVIEW. Is it possible to transfer files, if so how to transfer?
    Solved!
    Go to Solution.

    Yes, it is possible to transfer files with the serial port using LabVIEW.  Files are just collections of bytes and the serial port is pretty good at shipping bytes from one PC to another.  You need to connect the serial ports together with a null modem cable.
    First, take a look at the example for serial communication.   In LabVIEW, go to the Help menu and select "Find Examples...".  From there you can search for "serial" or navigate to Hardware Input and Output >> Serial.  Select the "Basic Serial Write and Read.vi".  Experiment with that example to gain confidence on the serial communication methods.
    Next, it's time to learn about how to read and write files.  For that, the examples could be somewhat confusing since they all deal with files that are presumed to have data of a specific type in them.  I would recommend just getting familiar with the functions on the File I/O palette.  Specifically, get to know the following functions.
    Open/Create/Replace File - On your destination side, you'll need to create the copy of the file that you are trying to transfer
    Close File - When you are finished reading from or writing to a file, you should close it.  It cleans up the memory being used and finalizes any write operations that are still floating in the write buffer.
    Read From Binary File - The best way to read from a file when you do not really care what type of file it is.  In your case, you just want to get those bytes read and sent out so they can be written down at the destination.
    Write to Binary File - At the destination side, this is what will store those bytes to the file you created with number 1.
    Get File Size (under the Advanced File Functions sub-palette) - You need to know how big the file is so you know when you are finished.
    OK, so once you are able to create files, write bytes to them, and read bytes from existing files you can move on to transferring.
    The basic method I would suggest is to have the user specify a source file on the source PC and a destination folder on the destination PC.  Then, find out the size of the source file using number 5.  Divide that size number by the number of bytes you feel like transferring at once.  The serial buffers are usually around 32k (if I remember correctly) so do not exceed that.  Now begin sending data by reading some number of bytes and wiring that string output to the VISA Write function.  On the destination side, you'll want to be monitoring the serial port for bytes and reading them when they arrive.  Wire that string to the Write to Binary File function to add them to your destination file.
    That is the basic outline of how to do it.  You have to be careful not to overload the write and read buffers on the serial ports.  Initially you can use delays on the sending side to make sure the reading side has enough time to digest.  To get things moving faster, you can bring in some flow control.
    If all that sounds a bit intimidating, there are Alliance Member companies out there (such as PrimeTest Automation) who can write such code for you and even provide a turnkey solution for you.
    Happy wiring,
    Dan Press
    Certified LabVIEW Architect
    PrimeTest Automation

  • How can i browse FP 2000 via serial port same use Ethernet port(RJ 45)?

    I am a new user for  labview.I develope my program with FP 2000 but I have some problem
      1 How can i browse FP 2000 via serial port same use Ethernet port(RJ 45)? if it can Tell me please.
      2 If  I use GSM/GPRS modem via FP 2000 rs 232 port (I under stand how to send AT command) and leave it stand alone
         Can I dial modem and browse file in FP 2000 same as use Ethernetport?
    Someone please help me.Thank you very much.

    Hi!
        First, I can say that your project involves many things, I cannot describe all features in the forum, and I'm not used with GPRS modems (my modems are base band serial modems...).
        Anyway, I would say that in your project you should proceed like this:
          1) Configure your FP 2000 module via MAX and ethernet connection;
          2) Download an embedded application to your module (build in LabView Real-Time)
          3) In your application, you should build a kind of serial port manager, and by the means of serial port you send/receive commands from PC.
        The commands from PC can include "Tell me the about the FP 2000 file system ", or "switch on line X", or anything you need.
       I think it would be difficult to use Internet exp, because you use IE with TCP/IP, and TCP/IP is over ethernet.
       I know that for Windows you can find some wrappers that make you "see" the serial port as an ethernet, but these wrapper do not exist under filed Point, and you shoul build one yourself!!!(and that's not easy).
        For example, to browse your files, you should build a VI that searches through your file system, and reports, via serial, the files present in a directory (it's an example....).
        About communication between GPRS modems and FP2000, I know nothing.  I suppose that these modems accept serial inputs, so you'll have to configure your serial port on FP 2000 with the correct baud rate, parity, and so on..... and you send your data to the modem.  The modem will transfer data in its way, no matter on how it does.
        To send data to your modem you shoud take a look to some Serial communication examples.  What I suggest you, first, is to connect the serial port of FP2000 to a PC, and test communication between PC and FP2000, without modems. Just direct cable connection!  If you're able to do this, insertion of modems is the next step, and should be quite easy.  If you're not able to make the PC receive strings of data from FP2000, over  RS232, adding modems is a further complication, and you won't come out of this mess!
       So, what I say, is just build, for now, a simple embedded application for FP2000, that, using RS232, sends data to a PC (you should see data sent with use of Hyper terminal).
        To build this application, use Instrument I/O --> VISA commands (VISA open, VISA write, and Property node should be enough, for now).
       Please, let me know if this helps......
        Have a nice (programming) day!
    graziano

  • LV acquire the print information from the embed board with Linux system through serial port

    I want to acquire the print information by LV from the embed board with Linux system through serial port, like the window hyperterminal tool?
    I try to use VISA serial config function to achieve it ,but lost and prompt that is error like attachment.
    I can't sure that my idea is reasonable.
    help me
    thanks a lot!

    I ended up finding the answer to my problem. After pointing a client directly at one of the DPS systems, I saw the following error in the logs:
    [27/Jul/2009:17:11:47 -0400] - OPERATION  - INFO  - conn=3688 op=4 BIND RESPONSE err=12 msg="The server is not configured to pass through control 1.3.6.1.4.1.42.2.27.8.5.1" etime=0After adding that control OID to the allowed-ldap-controls, I could login via password auth. Adding this control also allowed for password changes to work from a client system.

  • Export CDR via serial port

    The hardware platform is Cisco UCSC-C220-M3SBE, the Call Manager version is 8.6.2.22900-9.
    We manage to export the CDR to a sftp server. However, the bill system vendor requests us to export the CDR via serial port. 
    Is it possible to do it onto our platform in this case?

    On CUCM no, but with CME it can be done (by collecting syslog output). Otherwise you may exploit the CDRs on the voice gateway.
    It's not everytime that CUCM offers the required feature!

  • Files via serial port

    I need to send a jpg file via serial port. Have anyone an idea how to get it. I am using LabView 6.0.

    Hi Francesc,
    In order to solve this you will need:
    - a null modem cable (the difference is that pin 2in goes to pin 3out and pin 3in goes to pin 2out)
    - a normal serial communication VI (you can use the one in lv\examples)
    - to pass the data you have to transform your array of bytes (your file) in string at sender and reverse this operation at receiver. THE ONLY PROBLEM is with ASCII character 11 (even if the receiver has all your bytes in buffer it seems that will return to you just those before ASCII 11). Thus, you will have to avoid the transmission of this character. An idea will be to split each byte from file in other two for transmission - for example its hex code (so, 11 will be transmitted as 0B ). Of course, this method doubles the number of transmit
    ted bytes. If somebody found a better solution, please let me know.
    good luck

  • Connection Siemens TC65 to PC via serial port

    I don't connect Siemens TC65 via serial port . How can I do this? How can I upload java code in tc65..
    Is there anyone to solve this problem?

    tajava
    Welcome to the forum. Please refrain from posting in old threads that are long dead. When you have a question, please start a topic of your own. Feel free to provide a link to an old thread if relevant.
    I also suggest you go through these links before posting again:
    [How to ask questions the smart way|http://catb.org/~esr/faqs/smart-questions.html]
    [How To Get Good Answers To Your Questions|http://www.tek-tips.com/viewthread.cfm?qid=473997]
    I'm locking this thread now.
    db

  • RMI via serial port.

    I would like to use RMI via serial port.
    How can I do that?

    Thanks for the reply
    I can get it sending bytes of info from one machine to
    another but not to sure how I still send an object
    Wy do you think I should'nt be sending an object using
    rmiOK, if you have a setup working that involves writing bytes to an OutputStream at one end, and reading bytes from an InputStream at the other, then all you need to do is create an ObjectOutputStream at one end, and write the object to it.
        ObjectOutputStream oos = new ObjectOutputStream(myOutputStream);
        oos.writeObject(myObjectToSend);
        oos.close();and at the other end an ObjectInputStream:
        ObjectInputStream ois = new ObjectInputStream(myInputStream);
        MyObjectType myObjectToReceive = (MyObjectType) ois.readObject();
        ois.close();That should pretty much do it.
    The reason you should not be using RMI for this is that it relies on the existence of a netork layer that connects the two machines. PPP would have provided that, but there just doesn't seem a justification for that level of complexity here.
    Sylvia.

  • Problem communicating via serial port in Linux

    Hello,
    I am trying to transfer data via serial port, in Linux.
    But it is impossible till now!
    I get Runtime exception.
    Here is my code:
    public class Main {
        public Main() {
        int num=5;
        int[] array = new int[5];
        public static void main(String args[])  {
            java.awt.EventQueue.invokeLater(new Runnable() {
                public void run() {
                    array[0]=1;
                    array[1]=2;
                    array[2]=3;
                    array[3]=4;
                    array[4]=5;
                    new ParallelCommunication(num,array);
    import java.io.*;
    import java.util.*;
    import javax.comm.*; // for SUN's serial/parallel port libraries
    //import gnu.io.*; // for rxtxSerial library
    public class ParallelCommunication implements Runnable, SerialPortEventListener {
       static CommPortIdentifier portId;
       static CommPortIdentifier saveportId;
       static Enumeration portList;
       InputStream inputStream;
       SerialPort serialPort;
       Thread readThread;
       static OutputStream outputStream;
       static boolean outputBufferEmptyFlag = false;
       int num;
       int[] array;
       public ParallelCommunication(int this_num,int[] this_array) {
          boolean portFound = false;
          String defaultPort;
          num = this_num;
         array=new int[this_array.length];     
          array = this_array;     
          // determine the name of the serial port on several operating systems
          String osname = System.getProperty("os.name","").toLowerCase();
          if ( osname.startsWith("windows") ) {
             // windows
             defaultPort = "COM1";
          } else if (osname.startsWith("linux")) {
             // linux
            defaultPort = "/dev/ttyS0";
          } else {
             System.out.println("Sorry, your operating system is not supported");
             return;
    //      if (args.length > 0) {
    //         defaultPort = args[0];
          System.out.println("Set default port to "+defaultPort);
          // parse ports and if the default port is found, initialized the reader
          portList = CommPortIdentifier.getPortIdentifiers();
          while (portList.hasMoreElements()) {
             portId = (CommPortIdentifier) portList.nextElement();
             if (portId.getPortType() == CommPortIdentifier.PORT_SERIAL) {
                if (portId.getName().equals(defaultPort)) {
                   System.out.println("Found port: "+defaultPort);
                   portFound = true;
                   // init reader thread              
                   initialize();
                   break;
          if (!portFound) {
             System.out.println("port " + defaultPort + " not found.");
       public void initwritetoport() {
          // initwritetoport() assumes that the port has already been opened and
          //    initialized by "public void initialize()"
          try {
             // get the outputstream
             outputStream = serialPort.getOutputStream();
          } catch (IOException e) {}
          try {
             // activate the OUTPUT_BUFFER_EMPTY notifier
             serialPort.notifyOnOutputEmpty(true);
          } catch (Exception e) {
             System.out.println("Error setting event notification");
             System.out.println(e.toString());
             System.exit(-1);
       public void writetoport(int counter) {
          try {
             // write string to serial port
             outputStream.write(String.valueOf(array[counter]).getBytes());
          } catch (IOException e) {}
       public void initialize() {
          // initalize serial port
          try {
             serialPort = (SerialPort) portId.open("SimpleReadApp", 2000);
          } catch (PortInUseException e) {System.out.println("Port In Use.");}  //******Here is the Exception******
          try {
             inputStream = serialPort.getInputStream();
          } catch (IOException e) {}
          try {
             serialPort.addEventListener(this);
          } catch (TooManyListenersException e) {}
          // activate the DATA_AVAILABLE notifier
          serialPort.notifyOnDataAvailable(true);
          try {
             // set port parameters
             serialPort.setSerialPortParams(9600, SerialPort.DATABITS_8,
                         SerialPort.STOPBITS_1,
                         SerialPort.PARITY_NONE);
          } catch (UnsupportedCommOperationException e) {}
          // start the read thread
          readThread = new Thread(this);
          readThread.start();
       public void run() {
          // first thing in the thread, we initialize the write operation
         initwritetoport();     
         for(int i=0; i<=num_of_inputs; i++) {
            // write string to port, the serialEvent will read it
            writetoport(i);
         serialPort.close();     
       public void serialEvent(SerialPortEvent event) {
          switch (event.getEventType()) {
          case SerialPortEvent.BI:
          case SerialPortEvent.OE:
          case SerialPortEvent.FE:
          case SerialPortEvent.PE:
          case SerialPortEvent.CD:
          case SerialPortEvent.CTS:
          case SerialPortEvent.DSR:
          case SerialPortEvent.RI:
          case SerialPortEvent.OUTPUT_BUFFER_EMPTY:
             break;
          case SerialPortEvent.DATA_AVAILABLE:
             // we get here if data has been received
             byte[] readBuffer = new byte[20];
             try {
                // read data
                while (inputStream.available() > 0) {
                   int numBytes = inputStream.read(readBuffer);
                // print data
                String result  = new String(readBuffer);
                System.out.println("Read: "+result);
             } catch (IOException e) {}
             break;
    }...and the outcome is :
    Exception in thread "AWT-EventQueue-0" java.lang.RuntimeException:
    Error opening "/dev/ttyS0"
    tcgetattr(): Input/output error
    at com.sun.comm.LinuxDriver.getCommPort(LinuxDriver.java:66)
    at javax.comm.CommPortIdentifier.open(CommPortIdentifier.java:369)
    at ParallelCommunication.initialize(ParallelCommunication.java:128)
    I have searched a lot and I couldn't find a solution.
    Thank you.

    I'm having the same problem this helped somewhat debug the problem
    http://bloggerdigest.blogspot.com/2006/11/linux-serial-com-port-diagnostic-test.html
    I'm running Suse 10.3 and apparently it does not recognize my serial ports. So before
    you can test your Java code you have to figure out how to make linux see the ports.
    If I find a solution I'll let you know but if you find one first let me know. Thanks.

  • Problems on serial communicat​ion with an instrument

    Hello everybody!
    I'm having some problems interfacing with an Optical Spectrum Analyser from Anritsu via RS232. It has a GPIB interface that works well already, but i need to make communication work thru the serial port. If i use Measurement and Automation, i can write and read the commands alright. But, if i use a self made Labview vi, it doesn't work at all.
    My vi consisted on:
    ViOpen - ViWrite - ViRead - ViClose
    Normally, i can know when the communication initialized alright with the OSA because the instrument enters a "communication state". When i use M&A, it enters on that state. When i use Labview, it doesn't.
    I used NI Spy to see what differences were between the M&A and Labview. Here is a list of comm
    ands issued by M&A:
    viOpen(...,"ASRL1::INSTR",...)
    viInstallHandler(...) *
    viEnableEvent(...)
    viWriteAsync(...)
    viReadAsync(...)
    viClose(...)
    My Labview VI issues the following commands:
    viOpen(...,"ASRL1::INSTR",...)
    viWriteAsync(...)
    viReadAsync()
    viWaitonEvent()
    viWaitonEvent()
    viWaitonEvent()
    viTerminate()
    viClose()
    Labview returns a "problems in serial read" error, but i know that the program doesn't even begins communication with the OSA. I suspect that the error lies on that viInstallHandle function, that is ran in the M&A routine but it isn't on Labview, but i can't find a way to make a vi that runs this function.
    Anyone can help??? I am really frustrated because i know that serial communication works, but on M&A only!!!
    Thanks in advance
    Felipe

    I consulted the document "VISA and Serial Communication" from ni.com. It
    was helpful. I'm using Labview 6.
    I don't know how to get Labview to tell me what it is doing at the level of
    viTerminate(), etc., so I suppose I may not be able to contribute anything
    to you, but I did get my serial port working in Labview recently.
    I used a loopback test, by shorting pins 2 and 3, to verify that Labview was
    successfully sending and receiving from the chosen serial port.
    I made a .vi that let me do one thing at a time, initialize, write, and
    read. This helped me realize that the instrument wasn't very fast at
    getting back to me, when I was nailing down what I thought was a receiving
    problem.
    To get Labview to use the serial port on this system I had to uninstall a
    graphics tablet driver that was taking control of the port on bootup. VISA
    would report that there was a problem until I did this. Maybe if M&A runs
    first your OS still thinks the port is being used and won't let Labview use
    it.
    Also, depending on what serial .vi I was using, I needed to verify that I
    identified the port correctly. Port 0 in Labview, in my case, corresponds
    to COM1, this is for the "compatibility" .vis. When using VISA serial .vis,
    I discovered that COM1 was identified by VISA as ASRL1. However the default
    resource name that came up when putting a VISA serial .vi into a diagram was
    ASRL2 which does not exist on this system. Manually changing the "2" to a
    "1" in the front panel solved my problems.
    Your M&A and Labview VISA seem to agree on ASRL1, which might indicate that
    isn't the problem.
    I used the VISA interactive control to tell me how VISA was doing
    identifying the ports and which ports it thought it could use during any
    given session. This is available on my system in the VISA program group. If
    there are yellow question marks on ports in this program, the port in
    question has wandered away.
    There are some examples and functions in the directory:
    Labview 6\vi.llb\instr\serial.llb
    and also in the directory
    Labview 6\examples\instr\simplserl.llb,
    as well as
    Functions --> Instrument I/O --> Serial
    and
    Functions --> Instrument I/O --> I/O Compatibility --> Serial
    Compatibility
    "Felipe Ferri" wrote in message
    news:50650000000500000004140100-1042324653000@exch​ange.ni.com...
    > Thanks for your comment, but i tested the serial read and write
    > functions that you used on your program and they didn't work...

  • Communicate via serial port/ethernet from client app

    Hi
    Is it possible to communicate between the client serial port and an Apex application?
    (or from the application to an ethernet device).
    I need to link an application to a weighing machine and send/receive information via an Apex application. The interface will either be a serial port on the client or the weighing scales could also be connected as a network device.
    Any ideas?
    Thanks
    Kathryn

    There are active-x controls that you can use (http://www.activexperts.com/activcomport/howto/html/).. Otherwise you could try writing a small java applet to do this on the client end, don't know enough about your requirements to offer more.. Does the vendor of hardware have a solution?
    (Issue with this would be, non-ie browsers MIGHT not want to run vbscript or active-x controls..)
    Thank you,
    Tony Miller
    Webster, TX

  • Nokia 6600 connection with pc via serial port

    Hello friends
    I want to connection my nokia 6600 via the serial port, or infrared, to a pc. How can I do this? I have made a test with the CommConnection Interface, but it doesn�t work, it gives a port not found exception. Who can help me?
    Thanks tritonman

    Thanks a lot, but you now a phone which supported the completely CommConnection Interface to communicated with a pc over the serial port?
    Thanks tritonman

  • Join two 8 bit integers and send via Serial Port

    I am trying to join two 8 bit integers and send the result via the serial port.
    I have a constant of hex value A that I need to join with a value from hex 0 - F (this is based on incoming data)
    When I use the Join VI, and type cast to change from hex to string for Visa Write, I recieve hex 0A0F.
    I have been able to use the hex 0-F with a case structure and then wire the corresponding constant ex A0 - AF.
    This makes the program very cumbersome and labour intensive to change. I have 22 commands I have to respond to with the address of 0-F.
    Currently, I have a Case structure that is selected with Message ID, then a case that is selected with subtype and then a case for address.
    Therefore I have to create a constant inside of each address case for each message as the responses are different.
    Thanks for any help
    Robin

    Gambin,
    As I understand it, you want to take the two bytes, put them together,
    and output the result as an ASCII string on the serial port.  This
    is easy.  Simply convert each number to an ASCII string,
    concatonate the two characters together, and send the resulting string
    to the VISA write function.  That's it!  I have attached a VI
    (ver. 7.1) that takes two hex numbers as input, converts them to ASCII,
    concatonates the results, and outputs the 'command' string.  Fell
    free to modify this vi and use it as you see fit.  I have left
    extra terminals in case you want to add error input/output for data
    flow, or whatever.  Notice that the display for the concatonated
    string is in '/' Codes Display mode.  This is because 0A hex is
    the newline character in ASCII.  You should also check to make
    sure that your VISA serial settings are not setup so that the newline
    character is the termination character.  If it is, the second
    character may not be recognised.  Hope this helps.
    Roy
    Attachments:
    HextoCommand.vi ‏17 KB

  • Motion Control via Serial Port

    I have previously developed an automated video microscope application in Labview. It worked great. My setup was: NI PXI system with 1409 image board, 7344 motion controller, 7764 breakout box, stepper motors, motor drivers, and tables. Now, a customer is requiring that we use a specific brand of drivers that encompass a motion controller and are daisy-chained together. Communication will take place from a serial port, thereby bypassing the 7344. My question is: will I have to can my entire previous Labview motion/data acquisition program b/c I won't be using the 7344 controller? Or, will it be easy to specify in the program to commmunicate via the serial port rather than the card? Would this setup take place in MAX, or in the LabView applicatio
    n itself? Any nuances that I should know about? Any info would be appreciated. THANX-ROB

    Rob,
    in this case you won't be able to use any of your motion related code. The motion VIs in LabVIEW call the NI-Motion driver dll and thus they are not hardware independant. By the way, this is not a specific disadvantage of the NI-Motion driver. In fact there is not such a thing available like a standardized interface and hardware independant motion control language.
    In general you will have to use low level serial communication (VISA). That means you have to read the drive/controller manual, identify the serial command strings you need and send them to the device.
    For configuration the drive vendor should provide a utility to set the necessary parameters.
    On the other hand you could be lucky in the case that the vendor of the drive/controller provides h
    igh level LabVIEW vis. You should check with this vendor if a LabVIEW driver is available. Still you will have to rewrite your motion related part of the code.
    I'm sorry that there are no better news.
    Best regards,
    Jochen
    NI-Germany