200 Char Limit on Forms Messages solved

Is it possible to fit more then the default 200 characters in to a custom error message? Any help would be appreciated, thanks
Message was edited by:
Yachera

Creating a new database table or using text_io is completely unnecessary!
You could create a separate form and open the form as a modal window to display the error of any length.
But easiest might be to create a separate canvas with a control block item that can contain up to 32767 characters. Then just set the value of the item to whatever error message you need, then force the canvas to display by moving focus to that item with Go_Item.

Similar Messages

  • Variant Length 45 char limit - Help

    Friends,
    Iam developing a program to download all variants from current environment which are to be uploaded on other environment. Im using RS_VARIANT_CONTENTS FM. Problem is : when I Extract I get only 45 length limit for the variable value on the selection screen. This issue is with RSPARAMS structure which holds only upto 45 chars.
    Is there any other way to download and upload variants other than above FM. Like  for downloading program we use READ REPORT....anything as such (internal commands) exists for variants too....???????
    If any of you have faced this issue, please do pour in your valuable inputs.
    thanks

    Rob,
    Seems you might be thinking that my requirement is little wierd......lemme explain you in detail.
    We are moving from a Windows system to a Unix based as part of Upgrade. Because of this I have to change all the variants from
    P06XXXX\VAROPT\ to /var/opt/ps1/ and we are expecting variant file path's to have more than 45 characters but when its changed to Unix path for sure max chars would be 43 (below our 45 limit).
    My approach for this is :
    1) Use the code in OSS Note to download all variants from Windows box and upload in new Unix box (paths would still be
    P06XXXX\VAROPT\ ).
    2) Once all variants all loaded in their old format, I would now extract the selection screen strucutre (using FM), I could use FM to extract values also but again 45 char limit is haunting.
    3) Loop at the structure and IMPORT each variable. change variable content to Unix form and upload them using FM (RS_VARIANT_VALUE_CHANGE or similar).
    Now my problem : I am not able to use IMPORT statement in a LOOP.
    i.e.
    LOOP AT OBJECTS.
      IMPORT objects-name TO T_VAR FROM DATABASE VARI(VA) ID ST_KEY.
    ENDLOOP.
    Please help with this....
    thanks

  • How can i validate input number into a Field of  type char in oracle form?

    hi.....
    can any one help me.....please...!!!?!!
    How can i validate input number into a Field of type char in oracle form?

    i have tried doing that, but still the field except numbersthere was an error in that code. it should have been
    var_num:=to_number(var_char);however, it appears that you want the entry NOT to be a number. if this is the case then try
    begin
      if to_number(:block.item) = 0 then null; end if;
      message('The entry cannot be numeric');
      raise form_trigger_failure
    exception
      when value_error then
       /* this is where you put the code you want to be run when the
          entry is non-numeric */
    end;

  • 200 Email Limit!

    Confused why a 200 email limit for a device that has 16 gb (or at least 8 gb)? Hate to compare to BlackBerry, but they keep, best I can tell, thousands of emails or as many as the memory will hold I presume. Any way to up the number above 200?

    This setting is for the amount of messages to be shown in a mailbox - for the most recent messages in the mailbox.
    For a mailbox that contains more than 200 messages, at the bottom of the mailbox is a Load More Messages selection.
    The entire message for all messages in a mailbox are not downloaded and saved on the iPhone even with the show the 200 most recent messages seelction, with the exception of locally stored mailboxes on the iPhone - such as for the Drafts, Trash, and Sent mailboxes with a POP account.
    Only the message header and the number of preview lines for the message body chosen via Mail preferences are downloaded and available on the iPhone. Selecting a message downloads the message body from the server.
    This is probably done for those when roaming internationally to lower data downloads and the associated cost.

  • 200 Point Limit Exceeded

    We only have about 30 actual datapoints, but the PLC is handling all engineering unit conversion and alarm checking.  So for each datapoint requires that Lookout set or monitor 5 real values (Hi and Lo setpoints, Engr. conversion constants, and measured value) and 3 flags (hi and lo enable alarms and alarm indicator).  Which adds up to about 250 references on Modbus Plus which exceeds our 200 licenses limit.  How can I get Lookout to recognoze that there are only 30 actual datapoints??  We are using Lookout V5.1
    If this is not possible, how do I increase the license point limit and how much does it cost???

    Hello, In fact you do are using the 250 points that you mention. An IO point is not only the members for the PLC, but anything that has access to Citadel and Drivers.
    Check the following Link to learn how many IO points you have. Said this, you need to upgrade your license for more IO points.
    Ricardo S.
    National Instruments

  • Howto overcome the 255 char limit in XSLT when outputting using method=text

    Hi, I am facing a problem in my XSLT program to output a CSV file. The header line is exceeding 255 char limit, seems built into the editor and looks like it repeats the 255th character into the next line where it finishes the rest of the line. Now this screws the columns in the CSV file. I have tried different combinations of <xsl:text></xsl:text> tags but to no avail.
    Is there a way to overcome this problem, spanning a line onto multiple lines in SAP but getting a single line in the output ?
    Thanks in advance.
    Swapan

    I should have known better to searched in SAP provided documentation instead here first. I needed to end the line with &> chars to continue into the next line.
    http://help.sap.com/saphelp_erp2004/helpdata/en/50/b6463c32a3fe13e10000000a114084/frameset.htm

  • Is there a plugin that extends the limit of forms?

    Firefox imposes a limit on forms, I need to extend this limit to finish coding into an online database. The database can handle extensive code, but since we code online, Firefox as a web browser imposes a character limit

    A character limit would be imposed by the webpage.
    You can use an extension or a bookmarklet to see how many characters you have entered into the the text area, see
    * http://kb.mozillazine.org/Counts_-_Counting_bookmarks_history_links_and_other_data_-_Firefox
    <br />
    <br />
    <i><removed trailing dot(.) in link - edited by moderator></i>

  • Help! I need a simple powershell command to display all folders & files over the 260 char limit

    Can anyone help me please? I'm trying in vain to identify any files or folders I have in a directory over the 260 char limit.
    my powershell knowledge is quite limited so I've hit the wall with ideas.
    Any help appreciated.
    Thanks

    Would running this command on its own within powershell work?
    Or do I need to add this to your script?
    get-folderitem | Where {
    $_.fullname.length -gt 260

  • Char limit for .mov format?

    Originally posted in the iTunes for Mac forum but to no avail; I would really like to know if there is a char limit in the comments fields of the movie .mov format? When typing in comments for a .mov I find that only a certain amount save leading me to believe either:
    a) iTunes enforces a char limit
    b) .mov has a char limit
    Either way its a disaster for my media handling, I'm quite verbose.

    Hamper..don't hold your breath for a fix since 255 sounds horribly like a limit defined by the underlying architecture... Chances are that there is a single data byte that is used to tell iTunes just how many characters there are in the Comments field. As you may/may not know, one byte can only record a max of 255 characters.

  • Forms messages in Dutch in webforms

    What needs to be done in order to get the standard Forms messages (like '1 record applied and saved' or 'Field is protected against update') in Dutch in our webforms application?

    You set NLS on the application tier. If you want the same application to be available in 2 different languages then you start 2 different forms listeners on different ports with different NLS_LANG.
    For example - English users would be pointer to port 9000 and Dutch to 2001.
    I think this may be covered in the Forms Server FAQ. If you are using the new Forms Listener Servelt then you need to use PATCH 5 which allows you to use different environment settings for different listeners.
    Regards
    Grant Ronald

  • Form Message

    can I control the form message?
    I develop an entry screen. Every time went I create a new record
    and press save, a message will come out like :
    FRM-40440: Transaction Complete: 1 record applied and saved.
    In my <Save> button, I put down a 'commit' to update into my
    database. I feel that I should update into the database every
    time the user insert a new record not update a jum of record
    together when exit the from.
    Can I skip the form message?? I hope the your solution will
    also handle other than this form message.
    Thanks in Advance!
    Best regard,
    Eric
    null

    you can create an on-message-trigger or for some other cases an
    on error-trigger;
    I used them like this:
    DECLARE
    msgnum NUMBER := MESSAGE_CODE;
    BEGIN
    -- eventuell entstehende Meldungen fr das automatische
    Schliessen der Knoten unterdrcken
    IF (msgnum = 47323 or msgnum = 47314 or msgnum = 47316) THEN
    NULL;
    END IF;
    END;
    => as a result these messages are suppressed
    null

  • Oracle Forms Messages and  Codes

    Dear friends, will you, please, tell me, where can I find "Forms messages and codes manual"?

    <p>In the documentation, my friend.</p>

  • In Acrobat Pro XI, can I limit the form I created to "fill in and print," with no saving or signing?

    I created a fillable form from a word doc using Acrobat Pro XI. 
    When I look at the form in Acrobat Pro, I see the following at the top of the form:
    If I look at the form on a computer running just Adobe Reader, this is what displays at the top:
    I just want users to fill out and print this form.  The instruction that Adobe Reader is giving is confusing.  Can I modify those instructions, or change the file properties of my form somehow to limit to "fill out and print?"
    I don't recall encountering this before in earlier versions of Acrobat.

    Finally figured it out -- if I view the form directly in Adobe Reader (over our network), I see the confusing message about "Click 'Sign' to fill out..."
    BUT, if I open the form within a web browser (IE, Firefox, etc.), I see the usual message: "Please fill out the following form. You cannot save data typed into this form. Please print..."
    It is doing what I expected; I just wasn't viewing it in the usual manner.  Users will be seeing this form via a web browser, so problem solved.

  • What is the MAX. limit of a Message which PI can Handle?

    Hi Experts,
       We have one requirment where in we need to send a large data which contains some Memo Fields as well as Photo & PDF document thru PI Web-service scenario. we would like to know is there any Message Size Limit at PI side. is there any setting. i this moment i do not know what will be the size of the message will get form. pl. note that this will be B2B scenario.
         secondly for a given message how can i check the size of the message. we are on PI 7.31 JAVA Only SP9 Patch 11.
    Regards,
    Umesh

    Hi Umesh,
    as for as i know SAP PO system can handle the file till GB also but this will be based upon your system resources and configuration as well.
    Please find the below link for further information.
    http://scn.sap.com/community/pi-and-soa-middleware/blog/2010/10/18/pixi-pi-73-processing-of-large-files--teaser
    Regards,
    Naveen

  • Is it possible to limit number of messages in Inbox?

    Hello all,
    I was wondering if there is any way to limit the number of messages that show in your Mail inbox. Similar to how the iPhone limits it to 200...
    Thanks in advance,
    -Chris

    You could set up a smart mailbox to only show 200 of the messages in your inbox, with priority given to those most recently received...

Maybe you are looking for

  • Extremely Frustrated with Purchase and Lack of Customer Service

    I purchased an LG TV on 10/10 for $679.99 10/10, a week later I saw that Dell had the same television for $479. I called to Best Buy customer service and tried to price match. The man that I spoke with said no problem and that he would forward this r

  • Can't get past "terms of Use" screen at initial set-up

    I'm trying to set up our new Nano, but I can't get past the "Terms of Use/User Agreement" screen. There is just nothing showing up which will allow me to "accept" the terms. When you scroll to the bottom of the terms, there is nothing, and there are

  • Deleted Firefox by accident - can't find FF 2.0 download

    Help - I accidentally deleted Firefox from my machine and can't recover it. It looks like Firefox 2.0 is the only version that will work with my older software (OS X version 10.3.9). However, 2.0 is no longer available on the Mozilla site. I'm lookin

  • Change tab page at runtime

    hi all, I have to change the "page" property in "Tab target" on runtime in my application. For example if i have 7 page number set on my "Home" tab, can i change it to page no 11 on the fly in a PL-SQL process??? With Regards, Sunil Bhatia

  • Fpga simulation with simulated IO on development computer - synchronization to clock

    I would like to simulate an FPGA design using the "Simulated IO on development computer" concept. But for more complex designs such as ADC inputs or in my case cameraLink it is necessary to synchronize the stimulus and the response to the system cloc