Hello Folks,
There is a requirement to select and specify Table Fields on the Report Selection Screen. The UI should be something in a form of a Table Control or an Editable ALV grid. ALV Grid is the choice made for capturing the Table Fields (through classical Dynpro).
This Table Fields will be then read in the program to retrieve data from the DB table and finally display it in the dynamic ALV.
I am thinking of how to achieve the following:
- Is it possible to have an editable ALV grid on a Report Selection Screen? If yes, how can it be achieved.
- is it possible to save the contents (data) on the ALV grid in something like a report variant. So that the the user do not have to fill-up the data in the grid everytime.
Thank you
Well , Let this be a start for you. In the below code the alv is displayed in selection screen and the values can be saved as variant.
The dynamic table creation stuff's are discussed a lot here, please search for that. The below code is just written instantly and can be firther corrected and optimized.
Execute and check it once.
TYPE-POOLS:slis.
CLASS lcl_event_receiver DEFINITION DEFERRED.
TYPES:BEGIN OF ty,
field TYPE fld_namev,
END OF ty.
DATA:it TYPE TABLE OF ty,
wa TYPE ty,
fieldcat TYPE lvc_t_fcat,
l_valid TYPE c,
obj type ref to cl_gui_alv_grid,
g_verifier type ref to lcl_event_receiver,
wa_fcat type lvc_s_fcat,
repid type sy-repid,
dock type ref to cl_gui_docking_container.
CLASS lcl_event_receiver DEFINITION.
PUBLIC SECTION.
METHODS:
handle_data_changed
FOR EVENT data_changed OF cl_gui_alv_grid
IMPORTING er_data_changed.
ENDCLASS.
CLASS lcl_event_receiver IMPLEMENTATION.
METHOD handle_data_changed.
DATA:ls_good TYPE lvc_s_modi.
LOOP AT er_data_changed->mt_good_cells INTO ls_good.
ENDLOOP.
ENDMETHOD.
ENDCLASS.
PARAMETERS:pa_tab TYPE tabname16.
PARAMETERS:pa_str TYPE string NO-DISPLAY.
AT SELECTION-SCREEN OUTPUT.
IF NOT sy-slset IS INITIAL.
SPLIT pa_str AT cl_abap_char_utilities=>cr_lf INTO TABLE it.
ENDIF.
IF dock IS INITIAL.
repid = sy-repid.
CREATE OBJECT dock
EXPORTING
repid = repid
dynnr = sy-dynnr
ratio = 80
side = cl_gui_docking_container=>dock_at_bottom
name = 'DOCK_CONT'.
ENDIF.
IF obj IS INITIAL.
CREATE OBJECT obj
EXPORTING
i_parent = dock.
ENDIF.
IF fieldcat IS INITIAL.
wa_fcat-fieldname = 'FIELD'.
wa_fcat-seltext = 'Field Name'.
wa_fcat-edit = 'X'.
APPEND wa_fcat TO fieldcat.
ENDIF.
if g_verifier is initial.
CREATE OBJECT g_verifier.
SET HANDLER g_verifier->handle_data_changed FOR obj.
endif.
CALL METHOD obj->set_table_for_first_display
CHANGING
it_fieldcatalog = fieldcat
it_outtab = it.
CALL METHOD obj->set_ready_for_input
EXPORTING
i_ready_for_input = 1.
AT SELECTION-SCREEN.
IF sy-ucomm EQ 'SPOS'.
CALL METHOD obj->check_changed_data
IMPORTING e_valid = l_valid.
LOOP AT it INTO wa.
IF sy-tabix = 1.
pa_str = wa-field.
ELSE.
CONCATENATE pa_str cl_abap_char_utilities=>cr_lf
wa-field INTO pa_str.
ENDIF.
ENDLOOP.
ENDIF.
START-OF-SELECTION.
Similar Messages
-
Capturing the current ALV grid contents. How?
Hi forum,
After lots of searching, I still can't find out how I can get the current contents of the ALV grid. I need this for an editable ALV grid to keep track of the data changes.
By the way, I am using the traditional ALV, not OO ALV.
Let me share the steps I already did but still failed.
1
I used the FM GET_GLOBALS_FROM_SLVC_FULLSCR to have access to the CL_GUI_ALV_GRID object. I tried using some of the methods inside that class, all to no avail.
Some methods I tried were set_selected_columns and set_selected_rows and then call the method get_selected_cells. Basically, the idea is to simulate highlighting of cells, and select them using get_selected_cells. But the problem is that get_selected_cells is not returning the value (although it correctly returns the row and column that I set -- but not the value in that cell coordinates).
2
I also saw the protected method get_changed_data -- but the problem is that it is protected, so I created a subclass of CL_GUI_ALV_GRID to ZCL_GUI_ALV_GRID and copied the private attributes and methods that get_changed_data depends on. I was able to do this but GET_GLOBALS_FROM_SLVC_FULLSCR strictly returns CL_GUI_ALV_GRID. The upcast from CL_GUI_ALV_GRID to ZCL_GUI_ALV_GRID fails. So I still can't use/test get_changed_data.
3
I also saw some code regarding events. Here's a sample but this doesn't work:
REFRESH lt_events.
lwa_event-name = 'DATA_CHECK'. "Event name
lwa_event-form = 'HANDLE_DATA_CHANGED'.
APPEND lwa_event TO lt_events.
CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY_LVC'
EXPORTING
it_fieldcat_lvc = it_fieldcat
is_layout_lvc = ls_layout
it_events = lt_events
FORM handle_data_changed using ref_data_changed
type ref to cl_alv_changed_data_protocol.
BREAK-POINT.
ENDFORM.
I would really appreciate it (and I know a lot of other ABAPers will, too) if you could point me to how I can get the ALV grid contents. Thanks.
KyleHi Keshav,
sure I will check those tomorrow when I get back to work.
All,
Here's the code if it helps:
*& Report Z_ALV_EDITABLE
REPORT Z_ALV_EDITABLE.
TYPE-POOLS:
slis
DATA:
BEGIN OF i_out OCCURS 0,
operand1 TYPE i,
operand2 TYPE i,
operator TYPE c,
result TYPE i,
END OF i_out
START-OF-SELECTION.
PERFORM prepareData.
PERFORM refreshResults.
PERFORM createALV_LVC.
FORM prepareData.
REFRESH i_out.
DO 10 TIMES.
i_out-operand1 = 1.
i_out-operand2 = 2.
i_out-operator = '+'.
APPEND i_out.
ENDDO.
ENDFORM.
FORM refreshResults.
LOOP AT i_out.
CASE i_out-operator.
WHEN '+'.
i_out-result = i_out-operand1 + i_out-operand2.
WHEN '-'.
i_out-result = i_out-operand1 - i_out-operand2.
WHEN '*'.
i_out-result = i_out-operand1 * i_out-operand2.
WHEN '/'.
IF i_out-operand2 NE 0.
i_out-result = i_out-operand1 - i_out-operand2.
ENDIF.
WHEN OTHERS.
i_out-result = ''.
ENDCASE.
MODIFY i_out.
ENDLOOP.
ENDFORM.
FORM createALV_LVC.
DATA:
it_fieldcat TYPE lvc_t_fcat,
ls_layout TYPE lvc_s_layo,
lt_events TYPE slis_t_event,
lwa_event TYPE slis_alv_event
" Field Catalog
PERFORM createFieldcat CHANGING it_fieldcat.
" Sorting
PERFORM createSort.
" Layout
ls_layout-cwidth_opt = 'X'.
" Events
REFRESH lt_events.
lwa_event-name = 'DATA_CHECK'. "Event name
lwa_event-form = 'HANDLE_DATA_CHANGED'.
APPEND lwa_event TO lt_events.
CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY_LVC'
EXPORTING
it_fieldcat_lvc = it_fieldcat
is_layout_lvc = ls_layout
* it_sort =
it_events = lt_events
i_callback_program = 'Z_ALV_EDITABLE'
i_callback_user_command = 'USER_COMMAND'
i_callback_pf_status_set = 'PF_STATUS_SET'
i_save = 'X'
TABLES
t_outtab = i_out
EXCEPTIONS
program_error = 1
OTHERS = 2.
ENDFORM.
FORM createFieldcat CHANGING it_fieldcat TYPE lvc_t_fcat.
DATA:
wa_fcat LIKE LINE OF it_fieldcat
REFRESH it_fieldcat.
DEFINE m_append_fieldcat.
CLEAR wa_fcat.
wa_fcat-edit = &1.
wa_fcat-fieldname = &2.
wa_fcat-scrtext_m = &3.
APPEND wa_fcat TO it_fieldcat.
END-OF-DEFINITION.
m_append_fieldcat '' 'OPERAND1' 'Operand 1'.
m_append_fieldcat '' 'OPERAND2' 'Operand 2'.
m_append_fieldcat 'X' 'OPERATOR' 'Operator'.
m_append_fieldcat '' 'RESULT' 'Result'.
ENDFORM.
FORM createSort.
ENDFORM.
FORM PF_STATUS_SET USING P_EXTAB TYPE SLIS_T_EXTAB.
SET PF-STATUS 'Z_ALV_STATUS' EXCLUDING P_EXTAB.
ENDFORM. "PF_STATUS_SET
FORM user_command
USING
r_ucomm TYPE sy-ucomm
ls_selfield TYPE slis_selfield.
CASE r_ucomm.
WHEN 'REFRESH'.
" CHECK i_out HERE IF IT CHANGED ALONG WITH THE EDITS
BREAK-POINT.
* PERFORM refreshALV.
ENDCASE.
ENDFORM.
FORM handle_data_changed using ref_data_changed
type ref to cl_alv_changed_data_protocol.
BREAK-POINT.
ENDFORM. -
ECATT SAPGUI method to capture ALV grid contents
Dear All,
I am using eCATT SAPGUI method to record the transaction VF04. The problem here is I am unable to capture the contents of the ALV grid present in the transaction.
Were any one of you able to capture the contents of ALV grid using SAPGUI method, if so, please do help me to solve this problem.
Thanks in advance,
SidharthHi Sidharth,
Did u find any solution for this problem .
Iam facing same problem for MRIS,MRRL alv reports.Iam recording through SAP GUI but I want One out put field in log. If U find any solution for this plz forward to me.
Thanks in advance
Raju.K -
Visibility of ALV grid toolbar functions of the Custom report in ITS screen
Hi all,
I am working on SRM 5.0 with INTERNAL ITS.I have created a custom report and a transaction code for the same.Now in the SRM Web menu,I have provided a link for this report.
The problem I am facing is that in the O/P screen of the report,I have an ALV grid being displayed with 1 custom icon at the end of the std ALV toolbar.Now in the SAPGUI,this icon is displayed correctly at the end of the ALV toolbar but in the Web screen,i can see only few of the functions(visible as buttons in the SRM web screen/IE) in the ALV toolbar and rest of them being displayed under an additional button "MORE".Is there any way i can show the custom icon as a button which is directly visible on the SRM web screen and not under the options MORE?
All inputs will be highly appreciated and rewarded.Hello!
There are several possibilities how to call transaction:
- You can call it as service (that is what you do when you test it from SICF)
- You can call it through service (or alias) WEBGUI (not using service for the specific transaction to call it)
If you are calling it through WEBGUI then parameter ~SINGLETRANSACTION should be added to service (or alias) of WEBGUI. And there should be added also Log Off URL (in SICF). At this case it should navigate back to the URL which is specified in SICF.
Hope this helps!
Best regards,
Rorijs -
Running report with alv grid in background and exporting to excel
Hi Guys,
I've created a report program that uses the alv grid. When I run the report in foreground, I can easily export it to excel. However, if I run it in background, then display the spooled report and try to export to excel, it does not put it in excel format (seems to go over as one big column rather than individual columns that are defined in the report). Is there a way to run it in background ,export to excel properly and i have to email also in Excel sheet format.?
Thanks,
Gopi.In background u cannot do a download to excel. you can do is create CSV format file
or
write a report for output with tabs then call that report using
submit yXXXX exporting list to memory
and return.
call function 'LIST_FROM_MEMORY'
tables
listobject = report_list
exceptions
not_found = 1
others = 2.
and send the report_list to email users
a® -
Hi,
I am using ALV List and ALV grid in one of my custom reports.
There is no issue with ALV List when I print the report after running the program.
But when I use ALV Grid , the report runs good and when I try to print the report I get short dump "OBJECTS_NOT_CHARLIKE" in program "LKKBLF99" of the main program "SAPLKKBL".
I am using the function module "REUSE_ALV_GRID_DISPLAY" to run the report using ALV Grid and I get the above short dump when I try to print the report.
Can anyone help me please?
Thanks,
Ashok.Hai Ashok
Try with the following Code
*& Report ZALV_GRID *
REPORT ZALV_GRID .
TABLES: MARA.
TYPE-POOLS : SLIS.
Data declaration
DATA: BEGIN OF I_MARA OCCURS 0.
INCLUDE STRUCTURE MARA.
DATA: END OF I_MARA.
DATA: V_REPID LIKE SY-REPID.
selection-screen
SELECTION-SCREEN BEGIN OF BLOCK B1 WITH FRAME.
SELECT-OPTIONS : S_MATNR FOR MARA-MATNR.
PARAMETERS: P_MTART LIKE MARA-MTART DEFAULT 'ROH'.
SELECTION-SCREEN END OF BLOCK B1.
initialisation
INITIALIZATION.
S_MATNR-LOW = '1400'.
S_MATNR-HIGH = '1500'.
APPEND S_MATNR.
V_REPID = SY-REPID.
start-of-selection
START-OF-SELECTION.
SELECT * FROM MARA
INTO TABLE I_MARA
WHERE MATNR IN S_MATNR AND
MTART = P_MTART.
CHECK SY-SUBRC = 0.
end of selection
END-OF-SELECTION.
CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
EXPORTING
I_INTERFACE_CHECK = ' '
I_BYPASSING_BUFFER =
I_BUFFER_ACTIVE = ' '
I_CALLBACK_PROGRAM = ' '
I_CALLBACK_PF_STATUS_SET = ' '
I_CALLBACK_USER_COMMAND = ' '
I_STRUCTURE_NAME = 'MARA'
IS_LAYOUT =
IT_FIELDCAT =
IT_EXCLUDING =
IT_SPECIAL_GROUPS =
IT_SORT =
IT_FILTER =
IS_SEL_HIDE =
I_DEFAULT = 'X'
I_SAVE = ' '
IS_VARIANT =
IT_EVENTS =
IT_EVENT_EXIT =
IS_PRINT =
IS_REPREP_ID =
I_SCREEN_START_COLUMN = 0
I_SCREEN_START_LINE = 0
I_SCREEN_END_COLUMN = 0
I_SCREEN_END_LINE = 0
IMPORTING
E_EXIT_CAUSED_BY_CALLER =
ES_EXIT_CAUSED_BY_USER =
TABLES
T_OUTTAB = I_MARA
EXCEPTIONS
PROGRAM_ERROR = 1
OTHERS = 2
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
Thanks & Regards
Sreenivasulu P -
Hi all,
I have a subscreen with ALV grid in module pool program.
The main screen has two subscreens (one is header and other is items/reports)
from the main screen, the ALV Grid subscreen can be called in two ways.
1. from application tool bar (show report button) - ALV grid will be displayed in Items/Reports subscreen.
2. In Items/Reports subscreen, while displaying items there is a requirement to display same ALV grid subscreen report on hotspot of particular item.
ALV Grid in subscreen displaying only first come first serve for subscreen, if the subscreen called from application toolbar button then the ALV grid from items hotspot call not displaying and vice versa.
Not sure where i am doing wrong, but if i free the container, alv and re-generate all the objects its working fine but user doesn't like the flickering display of conatiner when it re-generating.
Any suggestions would help.
Regards
SyedHi Aruna Kumara,
Thanks for the reply.
I have only one ALV grid instance.
Process Flow from Application toolbar
Main Screen: 100
PBO:
CALL SUBSCREEN C_REPORT INCLUDING SY_REPID '0300'.
SUBSCREEN: 300
PBO:
IF CONTAINER IS NOT BOUND.
CREATE Container. with container name
CREATE ALV_Grid. passing container created
BUILD FIELDCAT.
CREATE EVENTS.
CALL METHOD SET_DISPLAY_TABLE_FIRST.
ELSE.
REFRESH_TABLE_DISPLAY.
FLUSH. "tried with without flush too.
ENDIF.
Process Flow from Items:
Items table is a subscreen 200 in main screen.
When the desired item click thru hotspot, a Modal dialog screen 250 open with subscreen element.
In event hotspot_click.
CALL SCREEN 250 STARTING AT ...ENDING AT.
PBO of 250:
CALL SUBSCREEN C_REPORT INCLUDING SY-REPID '0300'.
SubScreen 0300:
PBO as describe above, as the container already bound next time it refreshes the table display. But i see a blank screen in Popup.
Hope this helps.
Regards
Syed -
Read the posted messages but still have some query regarding layout of Header in ALV grid. Using ALV Grid (not OO concept) in the report.
- Can texts be printed in two sections in a single row like
Name : Designation:
Age: Cost Centre:
- How to increse the row size of the header. Right now have to scroll to see the complete header.
Looking forward for replies.
Thanks
anuThe font size depends on what you have specified for the parameter SLIS_LISTHEADER ( H = Header, S = Selection, A = Action are the valid values), I don't think we have selection of the font size as such.
So, in your case you can specify Name / Designation as Header and Age / Cost Center as Selection so that they appear in different font.
I am guessing you are using the function REUSE_ALV_COMMENTARY_WRITE, for writing the header.
regards,
Ravi
Note : Please mark all the helpful answers -
Hi
I have a alv grid display. when i run the report in background, i am able to see that a spool number is generated but i dont know how to check whether what is inside the spool is same as in ALV.here is FM i used
CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
EXPORTING
i_callback_program = report_id
i_callback_top_of_page = 'LIST_HEADING'
is_layout = i_layout
it_fieldcat = i_fieldcat
TABLES
t_outtab = ALV_OUT[]
EXCEPTIONS
program_error = 1
OTHERS = 2 -
I need simple example for alv grid
hi
i need code for simple example for alv grid.
thanks.hi bharat,
this is report with most of the functionality.
report zus_alv_demo_grid .
tables: ekko.
type-pools: slis.
types: begin of t_ekko,
ebeln type ekpo-ebeln,
ebelp type ekpo-ebelp,
statu type ekpo-statu,
aedat type ekpo-aedat,
matnr type ekpo-matnr,
menge type ekpo-menge,
meins type ekpo-meins,
netpr type ekpo-netpr,
peinh type ekpo-peinh,
line_color(4) type c, "Used to store row color
end of t_ekko.
data: it_ekko type standard table of t_ekko initial size 0,
wa_ekko type t_ekko.
*ALV data declarations
data: fieldcatalog type slis_t_fieldcat_alv with header line,
gd_tab_group type slis_t_sp_group_alv,
gd_layout type slis_layout_alv,
gd_repid like sy-repid.
Data declaration for EVENT and PRINT PARAMETER.
data: gt_events type slis_t_event,
gd_prntparams type slis_print_alv.
data declaration for sorting.
data : it_sortcat type slis_sortinfo_alv occurs 1,
wa_sort like line of it_sortcat.
data : i_list_comments type slis_t_listheader.
start-of-selection.
perform data_retrieval.
perform user_command.
perform build_fieldcatalog.
perform build_layout.
perform build_events.
perform build_print_params.
perform build_sortcat.
perform display_alv_report.
end-of-selection.
*TOP-OF-PAGE.
PERFORM top-of-page.
end-of-page.
*& Form build_fieldcatalog
text
--> p1 text
<-- p2 text
form build_fieldcatalog.
fieldcatalog-fieldname = 'EBELN'.
fieldcatalog-seltext_m = 'Purchase Order'.
fieldcatalog-col_pos = 0.
fieldcatalog-outputlen = 10.
fieldcatalog-emphasize = 'X'.
append fieldcatalog to fieldcatalog.
clear fieldcatalog.
fieldcatalog-fieldname = 'EBELP'.
fieldcatalog-seltext_m = 'PO Item'.
fieldcatalog-col_pos = 1.
append fieldcatalog to fieldcatalog.
clear fieldcatalog.
fieldcatalog-fieldname = 'STATU'.
fieldcatalog-seltext_m = 'Status'.
fieldcatalog-col_pos = 2.
append fieldcatalog to fieldcatalog.
clear fieldcatalog.
fieldcatalog-fieldname = 'AEDAT'.
fieldcatalog-seltext_m = 'Item change date'.
fieldcatalog-col_pos = 3.
append fieldcatalog to fieldcatalog.
clear fieldcatalog.
fieldcatalog-fieldname = 'MATNR'.
fieldcatalog-seltext_m = 'Material Number'.
fieldcatalog-col_pos = 4.
append fieldcatalog to fieldcatalog.
clear fieldcatalog.
fieldcatalog-fieldname = 'MENGE'.
fieldcatalog-seltext_m = 'PO quantity'.
fieldcatalog-col_pos = 5.
fieldcatalog-do_sum = 'X'.
append fieldcatalog to fieldcatalog.
clear fieldcatalog.
fieldcatalog-fieldname = 'MEINS'.
fieldcatalog-seltext_m = 'Order Unit'.
fieldcatalog-col_pos = 6.
append fieldcatalog to fieldcatalog.
clear fieldcatalog.
fieldcatalog-fieldname = 'NETPR'.
fieldcatalog-seltext_m = 'Net Price'.
fieldcatalog-col_pos = 7.
fieldcatalog-outputlen = 15.
fieldcatalog-datatype = 'CURR'.
append fieldcatalog to fieldcatalog.
clear fieldcatalog.
fieldcatalog-fieldname = 'PEINH'.
fieldcatalog-seltext_m = 'Price Unit'.
fieldcatalog-col_pos = 8.
append fieldcatalog to fieldcatalog.
clear fieldcatalog.
endform. " build_fieldcatalog
*& Form build_layout
text
--> p1 text
<-- p2 text
form build_layout.
gd_layout-no_input = 'X'.
gd_layout-colwidth_optimize = 'X'.
gd_layout-totals_text = 'Totals'(201).
Set layout field for row attributes(i.e. color)
gd_layout-info_fieldname = 'LINE_COLOR'.
gd_layout-totals_only = 'X'.
gd_layout-f2code = 'DISP'. "Sets fcode for
*when double
"click(press f2)*
gd_layout-group_change_edit = 'X'.
gd_layout-header_text = 'helllllo'.
endform. " build_layout
*& Form data_retrieval
text
--> p1 text
<-- p2 text
form data_retrieval.
data: ld_color(1) type c.
select ebeln ebelp statu aedat matnr menge meins netpr
peinh from ekpo into table it_ekko.
*Populate field with color attributes
loop at it_ekko into wa_ekko.
Populate color variable with colour properties
Char 1 = C (This is a color property)
Char 2 = 3 (Color codes: 1 - 7)
Char 3 = Intensified on/off ( 1 or 0 )
Char 4 = Inverse display on/off ( 1 or 0 )
i.e. wa_ekko-line_color = 'C410'
ld_color = ld_color + 1.
Only 7 colours so need to reset color value
if ld_color = 8.
ld_color = 1.
endif.
concatenate 'C' ld_color '10' into wa_ekko-line_color.
wa_ekko-line_color = 'C410'.
modify it_ekko from wa_ekko.
endloop.
endform. " data_retrieval
*& Form display_alv_report
text
--> p1 text
<-- p2 text
form display_alv_report.
gd_repid = sy-repid.
call function 'REUSE_ALV_GRID_DISPLAY'
exporting
i_callback_program = gd_repid
is_layout = gd_layout
i_callback_top_of_page = 'TOP-OF-PAGE'
i_callback_user_command = 'USER_COMMAND'
i_callback_pf_status_set = 'SET_PF_STATUS'
it_event = gt_events
is_print = gd_prntparams
it_fieldcat = fieldcatalog[]
it_sort = it_sortcat
i_save = 'X'
tables
t_outtab = it_ekko
exceptions
program_error = 1
others = 2.
if sy-subrc <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
endif.
endform. " DISPLAY_ALV_REPORT
*& Form user_command
text
--> p1 text
<-- p2 text
*& Form top-of-page
text
--> p1 text
<-- p2 text
form top-of-page.
*ALV Header declarations
data: t_header type slis_t_listheader,
wa_header type slis_listheader,
t_line like wa_header-info,
ld_lines type i,
ld_linesc(10) type c.
Title
wa_header-typ = 'H'.
wa_header-info = 'EKKO Table Report'.
append wa_header to t_header.
clear wa_header.
Date
wa_header-typ = 'S'.
wa_header-key = 'Date: '.
concatenate sy-datum+6(2) '.'
sy-datum+4(2) '.'
sy-datum(4) into wa_header-info."todays date
append wa_header to t_header.
clear: wa_header.
Total No. of Records Selected
describe table it_ekko lines ld_lines.
ld_linesc = ld_lines.
concatenate 'Total No. of Records Selected: ' ld_linesc
into t_line separated by space.
wa_header-typ = 'A'.
wa_header-info = t_line.
append wa_header to t_header.
clear: wa_header, t_line.
call function 'REUSE_ALV_COMMENTARY_WRITE'
exporting
it_list_commentary = t_header
i_logo = 'GANESH_LOGO'.
endform. " top-of-page
FORM user_command *
--> R_UCOMM *
--> RS_SELFIELD *
form user_command using r_ucomm like sy-ucomm
rs_selfield type slis_selfield.
case r_ucomm.
when '&IC1'.
if rs_selfield-fieldname = 'EBELN'.
read table it_ekko into wa_ekko index rs_selfield-tabindex.
set parameter id 'BES' field wa_ekko-ebeln.
call transaction 'ME23N' and skip first screen.
endif.
when 'ULHAS'.
if rs_selfield-fieldname = 'EBELN'.
read table it_ekko into wa_ekko index rs_selfield-tabindex.
set parameter id 'BES' field wa_ekko-ebeln.
call transaction 'ME23N' and skip first screen.
endif.
endcase.
endform.
FORM set_pf_status *
--> RT_EXTAB *
form set_pf_status using rt_extab type slis_t_extab.
set pf-status 'ZNEWSTATUS'.
endform.
*& Form build_events
text
--> p1 text
<-- p2 text
form build_events.
data: ls_event type slis_alv_event.
call function 'REUSE_ALV_EVENTS_GET'
exporting
i_list_type = 0
importing
et_events = gt_events[]
EXCEPTIONS
LIST_TYPE_WRONG = 1
OTHERS = 2
if sy-subrc <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
endif.
read table gt_events with key name = slis_ev_end_of_page
into ls_event.
if sy-subrc = 0.
move 'END_OF_PAGE' to ls_event-form.
append ls_event to gt_events.
endif.
read table gt_events with key name = slis_ev_end_of_list
into ls_event.
if sy-subrc = 0.
move 'END_OF_LIST' to ls_event-form.
append ls_event to gt_events.
endif.
endform. " build_events
*& Form build_print_params
text
--> p1 text
<-- p2 text
form build_print_params.
gd_prntparams-reserve_lines = '3'. "Lines reserved for footer
gd_prntparams-no_coverpage = 'X'.
endform. " build_print_params
FORM END_OF_PAGE *
form end_of_page.
data: listwidth type i,
ld_pagepos(10) type c,
ld_page(10) type c.
write: sy-uline(50).
skip. write:/40 'Page:', sy-pagno .
endform.
FORM END_OF_LIST *
form end_of_list.
data: listwidth type i,
ld_pagepos(10) type c,
ld_page(10) type c.
skip. write:/40 'Page:', sy-pagno .
endform.
*& Form build_sortcat
text
--> p1 text
<-- p2 text
form build_sortcat.
wa_sort-spos = 1.
wa_sort-fieldname = 'EBELN'.
append wa_sort to it_sortcat.
wa_sort-spos = 2.
wa_sort-fieldname = 'EBELP'.
append wa_sort to it_sortcat.
endform. " build_sortcat
Rewards if helpfull
regards
vijay dwivedi -
Hi all,
i am having one issue regarding ALV GRID.
my issue is after executin report O/P in grid format is ok,
but the same format i want to display when u click print preview or when u execute it in back ground,
it is displaying as same as ALV LIST,hi use the coding like this,
here i am calling hirarchial from list check this....
*& Report ZZZ00
REPORT ZPR_02.
TYPE-POOLS: SLIS.
TABLES:pa0002,pa0008.
data:begin of it_pa0002 occurs 0,
checkbox,
pernr like pa0002-pernr,
begda like pa0002-begda,
endda like pa0002-endda,
vorna like pa0002-vorna,
nachn like pa0002-nachn,
end of it_pa0002.
data:begin of it_pa00021 occurs 0,
pernr like pa0002-pernr,
begda like pa0002-begda,
endda like pa0002-endda,
vorna like pa0002-vorna,
nachn like pa0002-nachn,
expand TYPE xfeld value 'X',
end of it_pa00021.
data:begin of it_pa0008 occurs 0,
pernr like pa0008-pernr,
begda like pa0008-begda,
endda like pa0008-endda,
ANSAL like pa0008-ANSAL,
LGA01 like pa0008-LGA01,
BET01 LIKE PA0008-BET01,
end of it_pa0008.
DATA: IT_FIELD_CAT TYPE SLIS_T_FIELDCAT_ALV,
IT_FIELD_CAT1 TYPE SLIS_T_FIELDCAT_ALV,
IT_LAYOUT1 TYPE SLIS_LAYOUT_ALV,
WA_FIELD_CAT TYPE SLIS_FIELDCAT_ALV,
WA_FIELD_CAT1 TYPE SLIS_FIELDCAT_ALV,
IT_LAYOUT TYPE SLIS_LAYOUT_ALV,
IT_EVENTS TYPE SLIS_T_EVENT,
WA_EVENTS TYPE SLIS_ALV_EVENT,
IT_HEADER TYPE SLIS_T_LISTHEADER,
WA_HEADER TYPE SLIS_LISTHEADER,
wa_keyinfo TYPE slis_keyinfo_alv.
CONSTANTS:c VALUE 'X'.
SELECT-OPTIONS: S_pernr FOR pa0002-pernr.
START-OF-SELECTION.
SET PF-STATUS 'DATA' .
PERFORM GET_DATA.
PERFORM BUILD_FIELD_CAT.
PERFORM GET_EVENTS.
PERFORM DISPLAY_DATA.
*& Form get_data
text
FORM GET_DATA .
SELECT pernr
begda
endda
vorna
nachn
FROM pa0002
INTO CORRESPONDING FIELDS OF TABLE IT_pa0002
WHERE pernr IN S_pernr.
ENDFORM. " get_data
*& Form build_field_cat
text
FORM BUILD_FIELD_CAT .
wa_field_cat-tabname = 'PA0002'.
WA_FIELD_CAT-FIELDNAME = 'CHECKBOX'.
wa_field_cat-ref_tabname = 'IT_PA0002'.
WA_FIELD_CAT-REPTEXT_DDIC = 'Check Box'.
APPEND WA_FIELD_CAT TO IT_FIELD_CAT.
CLEAR WA_FIELD_CAT.
wa_field_cat-tabname = 'PA0002'.
WA_FIELD_CAT-FIELDNAME = 'PERNR'.
wa_field_cat-ref_tabname = 'IT_PA0002'.
WA_FIELD_CAT-REPTEXT_DDIC = 'Personnel no'.
APPEND WA_FIELD_CAT TO IT_FIELD_CAT.
CLEAR WA_FIELD_CAT.
wa_field_cat-tabname = 'PA0002'.
WA_FIELD_CAT-FIELDNAME = 'BEGDA'.
wa_field_cat-ref_tabname = 'IT_PA0002'.
WA_FIELD_CAT-REPTEXT_DDIC = 'Start date'.
APPEND WA_FIELD_CAT TO IT_FIELD_CAT.
CLEAR WA_FIELD_CAT.
wa_field_cat-tabname = 'PA0002'.
WA_FIELD_CAT-FIELDNAME = 'ENDDA'.
wa_field_cat-ref_tabname = 'IT_PA0002'.
WA_FIELD_CAT-REPTEXT_DDIC = 'End date'.
APPEND WA_FIELD_CAT TO IT_FIELD_CAT.
CLEAR WA_FIELD_CAT.
wa_field_cat-tabname = 'PA0002'.
WA_FIELD_CAT-FIELDNAME = 'VORNA'.
wa_field_cat-ref_tabname = 'IT_PA0002'.
WA_FIELD_CAT-REPTEXT_DDIC = 'First name'.
APPEND WA_FIELD_CAT TO IT_FIELD_CAT.
CLEAR WA_FIELD_CAT.
wa_field_cat-tabname = 'PA0002'.
WA_FIELD_CAT-FIELDNAME = 'NACHN'.
wa_field_cat-ref_tabname = 'IT_PA0002'.
WA_FIELD_CAT-REPTEXT_DDIC = 'Last name'.
APPEND WA_FIELD_CAT TO IT_FIELD_CAT.
CLEAR WA_FIELD_CAT.
wa_field_cat1-tabname = 'PA0002'.
WA_FIELD_CAT1-FIELDNAME = 'PERNR'.
wa_field_cat1-ref_tabname = 'IT_PA00021'.
WA_FIELD_CAT1-REPTEXT_DDIC = 'Personnel no'.
APPEND WA_FIELD_CAT1 TO IT_FIELD_CAT1.
CLEAR WA_FIELD_CAT1.
wa_field_cat1-tabname = 'PA0002'.
WA_FIELD_CAT1-FIELDNAME = 'BEGDA'.
wa_field_cat1-ref_tabname = 'IT_PA00021'.
WA_FIELD_CAT1-REPTEXT_DDIC = 'Start date'.
APPEND WA_FIELD_CAT1 TO IT_FIELD_CAT1.
CLEAR WA_FIELD_CAT1.
wa_field_cat1-tabname = 'PA0002'.
WA_FIELD_CAT1-FIELDNAME = 'ENDDA'.
wa_field_cat1-ref_tabname = 'IT_PA00021'.
WA_FIELD_CAT1-REPTEXT_DDIC = 'End date'.
APPEND WA_FIELD_CAT1 TO IT_FIELD_CAT1.
CLEAR WA_FIELD_CAT1.
wa_field_cat1-tabname = 'PA0002'.
WA_FIELD_CAT1-FIELDNAME = 'VORNA'.
wa_field_cat1-ref_tabname = 'IT_PA00021'.
WA_FIELD_CAT1-REPTEXT_DDIC = 'First name'.
APPEND WA_FIELD_CAT1 TO IT_FIELD_CAT1.
CLEAR WA_FIELD_CAT.
wa_field_cat1-tabname = 'PA0002'.
WA_FIELD_CAT1-FIELDNAME = 'NACHN'.
wa_field_cat1-ref_tabname = 'IT_PA00021'.
WA_FIELD_CAT1-REPTEXT_DDIC = 'Last name'.
APPEND WA_FIELD_CAT1 TO IT_FIELD_CAT1.
CLEAR WA_FIELD_CAT1.
wa_field_cat1-tabname = 'PA0008'.
wa_field_cat1-fieldname = 'PERNR'.
wa_field_cat-ref_tabname = 'IT_PA0008'.
wa_field_cat1-REPTEXT_DDIC = 'personnelno'.
APPEND wa_field_cat1 TO it_field_cat1.
CLEAR WA_FIELD_CAT1.
wa_field_cat1-tabname = 'PA0008'.
wa_field_cat1-fieldname = 'BEGDA'.
wa_field_cat-ref_tabname = 'IT_PA0008'.
wa_field_cat1-REPTEXT_DDIC = 'begindate'.
APPEND wa_field_cat1 TO it_field_cat1.
CLEAR WA_FIELD_CAT1.
wa_field_cat1-tabname = 'PA0008'.
wa_field_cat1-fieldname = 'ENDDA'.
wa_field_cat-ref_tabname = 'IT_PA0008'.
wa_field_cat1-REPTEXT_DDIC = 'enddate'.
APPEND wa_field_cat1 TO it_field_cat1.
CLEAR WA_FIELD_CAT1.
wa_field_cat1-tabname = 'PA0008'.
wa_field_cat1-fieldname = 'ANSAL'.
wa_field_cat-ref_tabname = 'IT_PA0008'.
wa_field_cat1-REPTEXT_DDIC = 'annualsalary'.
APPEND wa_field_cat1 TO it_field_cat1.
CLEAR WA_FIELD_CAT1.
wa_field_cat1-tabname = 'PA0008'.
wa_field_cat1-fieldname = 'LGA01'.
wa_field_cat-ref_tabname = 'IT_PA0008'.
wa_field_cat1-REPTEXT_DDIC = 'wagetype'.
APPEND wa_field_cat1 TO it_field_cat1.
CLEAR WA_FIELD_CAT1.
wa_field_cat1-tabname = 'PA0008'.
wa_field_cat1-fieldname = 'BET01'.
wa_field_cat-ref_tabname = 'IT_PA0008'.
wa_field_cat1-REPTEXT_DDIC = 'Amount'.
APPEND wa_field_cat1 TO it_field_cat1.
CLEAR WA_FIELD_CAT1.
ENDFORM. " build_field_cat
*& Form display_data
text
FORM DISPLAY_DATA .
it_layout-box_fieldname = 'CHECKBOX'.
it_layout-EDIT = 'X'.
CALL FUNCTION 'REUSE_ALV_LIST_DISPLAY'
EXPORTING
I_CALLBACK_PROGRAM = SY-REPID
I_CALLBACK_PF_STATUS_SET = 'PF_STATUS'
I_CALLBACK_USER_COMMAND = 'USER_COMMAND'
IT_FIELDCAT = IT_FIELD_CAT
IS_LAYOUT = IT_LAYOUT
IT_EVENTS = IT_EVENTS
TABLES
T_OUTTAB = IT_pa0002.
ENDFORM. " display_data
*& Form get_events
text
FORM GET_EVENTS .
CALL FUNCTION 'REUSE_ALV_EVENTS_GET'
IMPORTING
ET_EVENTS = IT_EVENTS .
READ TABLE IT_EVENTS INTO WA_EVENTS
WITH KEY NAME = SLIS_EV_TOP_OF_PAGE.
IF SY-SUBRC = 0.
WA_EVENTS-FORM = 'TOP_OF_PAGE'.
MODIFY IT_EVENTS FROM WA_EVENTS INDEX SY-TABIX.
ENDIF.
ENDFORM. " get_events
*& Form top_of_page
text
FORM TOP_OF_PAGE.
WA_HEADER-TYP = 'H'.
WA_HEADER-INFO = 'EMPLOYEE DATA'.
APPEND WA_HEADER TO IT_HEADER.
CALL FUNCTION 'REUSE_ALV_COMMENTARY_WRITE'
EXPORTING
IT_LIST_COMMENTARY = IT_HEADER
ENDFORM. "top_of_page
*& Form GUI_SET
FORM GUI_SET USING RT_EXTAB TYPE SLIS_T_EXTAB .
SET PF-STATUS 'DATA' .
ENDFORM. "GUI_SET
*& Form USER_COMMAND
FORM USER_COMMAND USING R_UCOMM LIKE SY-UCOMM
R_SELFIELD TYPE SLIS_SELFIELD.
DATA:V_PERNR LIKE PA0002-PERNR.
CASE R_UCOMM.
WHEN 'DET'.
DATA: V_FLAG.
clear : v_flag.
LOOP AT IT_PA0002.
if it_PA0002-checkbox = 'X'.
v_flag = 'X'.
v_pernr = IT_PA0002-PERNR.
SELECT PERNR
BEGDA
ENDDA
VORNA
NACHN
FROM PA0002
INTO CORRESPONDING FIELDS OF TABLE IT_PA00021
WHERE PERNR = V_PERNR.
SORT IT_PA00021 BY PERNR.
DELETE ADJACENT DUPLICATES FROM IT_PA00021 COMPARING PERNR.
READ TABLE IT_PA00021 INDEX 1.
SELECT PERNR
BEGDA
ENDDA
ANSAL
LGA01
BET01
FROM PA0008
INTO TABLE IT_PA0008
FOR ALL ENTRIES IN IT_PA00021
WHERE PERNR = IT_PA00021-PERNR.
if not it_PA0008[] Is initial.
SORT IT_PA0008 BY PERNR.
delete adjacent duplicates from it_PA0008 comparing pernr.
READ TABLE IT_PA0008 INDEX 1.
endif.
endif.
enddo.
it_layout1-group_change_edit = c.
it_layout1-colwidth_optimize = c.
it_layout1-zebra = c.
it_layout1-detail_popup = c.
it_layout1-get_selinfos = c.
it_layout-expand_fieldname = 'EXPAND'.
wa_keyinfo-header01 = 'PERNR'.
wa_keyinfo-item01 = 'PERNR'.
IF NOT V_FLAG IS INITIAL.
CALL FUNCTION 'REUSE_ALV_HIERSEQ_LIST_DISPLAY'
EXPORTING
I_CALLBACK_PROGRAM = SY-REPID
IS_LAYOUT = IT_LAYOUT1
IT_FIELDCAT = IT_FIELD_CAT1
I_TABNAME_HEADER = 'PA0002'
I_TABNAME_ITEM = 'PA0008'
IS_KEYINFO = wa_keyinfo
TABLES
T_OUTTAB_HEADER = IT_PA00021
T_OUTTAB_ITEM = IT_PA0008.
ENDIF.
CLEAR: IT_PA00021,IT_PA0002,IT_PA0008.
ENDLOOP.
WHEN 'BACK'.
EXIT.
ENDCASE.
ENDFORM. "USER_COMMAND
reward points if useful,
venkat. -
ALV GRID Display function module giving Run time error
Hello Experts,
I have ALV report, In which I am using ALV grid dispaly FM to display the report.
But when my out table which I am passing to FM is empty that time ALV grid display shows blank ALV report. but when out table is not empty that time I am getting the Run time error, which shows message "Field symbol has not yet been assigned".
Can any one please help me out in this.
ThanksTYPES: BEGIN OF type_out,
col00 TYPE ytlet-rzzyyproduct,
col01 TYPE ytlet-kslvt,
col02 TYPE ytlet-kslvt,
col03 TYPE ytlet-kslvt,
col04 TYPE ytlet-kslvt,
col05 TYPE ytlet-kslvt,
col06 TYPE ytlet-kslvt,
col07 TYPE ytlet-kslvt,
col08 TYPE ytlet-kslvt,
col09 TYPE ytlet-kslvt,
col10 TYPE ytlet-kslvt,
col11 TYPE ytlet-kslvt,
col12 TYPE ytlet-kslvt,
col13 TYPE ytlet-kslvt,
col14 TYPE ytlet-kslvt,
col15 TYPE ytlet-kslvt,
col16 TYPE ytlet-kslvt,
col17 TYPE ytlet-kslvt,
col18 TYPE ytlet-kslvt,
col19 TYPE ytlet-kslvt,
col20 TYPE ytlet-kslvt,
col21 TYPE ytlet-kslvt,
col22 TYPE ytlet-kslvt,
col23 TYPE ytlet-kslvt,
col24 TYPE ytlet-kslvt,
col25 TYPE ytlet-kslvt,
col26 TYPE ytlet-kslvt,
col27 TYPE ytlet-kslvt,
col28 TYPE ytlet-kslvt,
col29 TYPE ytlet-kslvt,
col30 TYPE ytlet-kslvt,
col31 TYPE ytlet-kslvt,
col32 TYPE ytlet-kslvt,
col33 TYPE ytlet-kslvt,
col34 TYPE ytlet-kslvt,
col35 TYPE ytlet-kslvt,
col36 TYPE ytlet-kslvt,
col37 TYPE ytlet-kslvt,
col38 TYPE ytlet-kslvt,
col39 TYPE ytlet-kslvt,
col40 TYPE ytlet-kslvt,
col41 TYPE ytlet-kslvt,
col42 TYPE ytlet-kslvt,
col43 TYPE ytlet-kslvt,
col44 TYPE ytlet-kslvt,
END OF type_out.
DATA: t_fieldcat TYPE slis_t_fieldcat_alv, "Field catelog table
w_fieldcat TYPE slis_fieldcat_alv, "Field catelog Work area
w_layout TYPE slis_layout_alv, "Layout structure
w_event TYPE slis_alv_event, "Event structure
t_event TYPE slis_t_event, "Event structure
t_sort TYPE STANDARD TABLE OF slis_sortinfo_alv,
t_callback_main_user_command TYPE slis_formname,
v_selfield TYPE slis_selfield.
FIELD-SYMBOLS: <ksl>.
FORM DISPLAY_REPORT .
*Prepare Field Catlog
PERFORM creat_field_catlog.
*Set layout
PERFORM set_layout.
*Get Event
PERFORM get_event.
*Display Report
PERFORM display_alv_report.
ENDFORM. " DISPLAY_REPORT
FORM creat_field_catlog .
PERFORM add_fields_catlog USING:
'01' 'RZZYYPRODUCT' 'IT_OUT' 'MPMs' ' ',
'02' 'KSLVT' 'IT_OUT' 'License Fee' ' ',
'03' 'KSLVT' 'IT_OUT' 'Ad Sales' ' ',
'04' 'KSLVT' 'IT_OUT' 'Promo Fees' ' ',
'05' 'KSLVT' 'IT_OUT' 'Total Ad Sales/Promo' ' ',
'06' 'KSLVT' 'IT_OUT' 'Other' ' ',
'07' 'KSLVT' 'IT_OUT' 'Total' ' ',
'08' 'KSLVT' 'IT_OUT' 'Dom Station' ' ',
'09' 'KSLVT' 'IT_OUT' 'Basic Cable/Free VOD' ' ',
'10' 'KSLVT' 'IT_OUT' 'License Fee' ' ',
'11' 'KSLVT' 'IT_OUT' 'Ad Sales (incl Internet)' ' ',
'12' 'KSLVT' 'IT_OUT' 'Promo Fees' ' ',
'13' 'KSLVT' 'IT_OUT' 'Ad Sales & Promo Fees' ' ',
'14' 'KSLVT' 'IT_OUT' 'Foreign' ' ',
'15' 'KSLVT' 'IT_OUT' 'Pay TV' ' ',
'16' 'KSLVT' 'IT_OUT' 'Other' ' ',
'17' 'KSLVT' 'IT_OUT' 'Total' ' ',
'18' 'KSLVT' 'IT_OUT' 'Home Entertainment' ' ',
'19' 'KSLVT' 'IT_OUT' 'SPTI' ' ',
'20' 'KSLVT' 'IT_OUT' 'All Other Divisions' ' ',
'21' 'KSLVT' 'IT_OUT' 'Total' ' ',
'22' 'KSLVT' 'IT_OUT' 'Total Revenue' ' ',
'23' 'KSLVT' 'IT_OUT' 'PV Net Down & Producers Share' '',
'24' 'KSLVT' 'IT_OUT' 'Total Net Revenue' ' ',
'25' 'KSLVT' 'IT_OUT' 'Development Expense' ' ',
'26' 'KSLVT' 'IT_OUT' 'SOP Deficits' ' ',
'27' 'KSLVT' 'IT_OUT' 'Amortization' ' ',
'28' 'KSLVT' 'IT_OUT' 'Other COS ' ' ',
'29' 'KSLVT' 'IT_OUT' 'Total COS' ' ',
'30' 'KSLVT' 'IT_OUT' 'Profit Before Releasing' ' ',
'31' 'KSLVT' 'IT_OUT' 'Gross Profit %' ' ',
'32' 'KSLVT' 'IT_OUT' 'SPT' ' ',
'33' 'KSLVT' 'IT_OUT' 'Home Entertainment' ' ',
'34' 'KSLVT' 'IT_OUT' 'SPTI' ' ',
'35' 'KSLVT' 'IT_OUT' 'All Other Divisions' ' ',
'36' 'KSLVT' 'IT_OUT' 'Other' ' ',
'37' 'KSLVT' 'IT_OUT' 'Total' ' ',
'38' 'KSLVT' 'IT_OUT' 'Gross Profit' ' ',
'39' 'KSLVT' 'IT_OUT' 'SPT' ' ',
'40' 'KSLVT' 'IT_OUT' 'Home Entertainment' ' ',
'41' 'KSLVT' 'IT_OUT' 'SPTI' ' ',
'42' 'KSLVT' 'IT_OUT' 'All Other Divisions' ' ',
'43' 'KSLVT' 'IT_OUT' 'Other' ' ',
'44' 'KSLVT' 'IT_OUT' 'Total' ' ',
'45' 'KSLVT' 'IT_OUT' 'Net Margin' ' '.
ENDFORM. " CREAT_FIELD_CATLOG
*& Form ADD_FIELDS_CATLOG
Filling of field Catlog
FORM add_fields_catlog USING p_colpos
p_fildname
p_tabname
p_fildtext
p_ndisplay.
w_fieldcat-row_pos = '1'.
w_fieldcat-col_pos = p_colpos.
w_fieldcat-fieldname = p_fildname.
w_fieldcat-tabname = p_tabname.
w_fieldcat-reptext_ddic = p_fildtext.
w_fieldcat-no_out = p_ndisplay.
APPEND w_fieldcat TO t_fieldcat.
CLEAR: w_fieldcat.
ENDFORM. " ADD_FIELDS_CATLOG
*& Form SET_LAYOUT
Set Layout
FORM set_layout .
w_layout-colwidth_optimize = 'X'.
ENDFORM. " SET_LAYOUT
*& Form GET_EVENT
text
FORM get_event .
w_event-name = 'TOP-OF-PAGE'.
w_event-form = 'F_TOP-OF_PAGE'.
APPEND w_event TO t_event.
ENDFORM. " GET_EVENT
*& Form TOP-OF-PAGE
Top of Page
FORM top-of-page.
DATA : t_list_commentry TYPE slis_t_listheader,
w_header TYPE slis_listheader,
lv_text(90) TYPE c,
l_text(90) TYPE c,
lv_rundate(10) TYPE c,
lv_runtime(10) TYPE c.
CONSTANTS: c_space(2) TYPE c VALUE ' ',
c_space2(6) TYPE c VALUE ' '.
w_header-typ = 'S'.
w_header-key = 'Program:'.
w_header-info = sy-repid.
APPEND w_header TO t_list_commentry.
WRITE: sy-datum TO lv_rundate MM/DD/YYYY.
WRITE: sy-uzeit TO lv_runtime USING EDIT MASK '__:__:__'.
CLEAR w_header.
w_header-typ = 'S'.
w_header-key = text-021.
w_header-info = lv_rundate.
APPEND w_header TO t_list_commentry.
CLEAR: w_header.
w_header-typ = 'S'.
w_header-key = 'User Id'.
w_header-info = sy-uname.
APPEND w_header TO t_list_commentry.
CLEAR: w_header.
w_header-typ = 'S'.
w_header-key = 'Run Date'.
w_header-info = lv_rundate.
APPEND w_header TO t_list_commentry.
CLEAR: w_header.
w_header-typ = 'S'.
w_header-key = 'Run Time'.
w_header-info = lv_runtime.
APPEND w_header TO t_list_commentry.
CLEAR: w_header.
w_header-typ = 'H'.
w_header-key = 'order'.
w_header-info = 'MCR Report'.
APPEND w_header TO t_list_commentry.
CALL FUNCTION 'REUSE_ALV_COMMENTARY_WRITE'
EXPORTING
it_list_commentary = t_list_commentry.
ENDFORM. "TOP-OF-PAGE
FORM display_alv_report .
CONSTANTS : gc_save TYPE c VALUE 'A'. "Save Layout
t_callback_main_user_command = c_user_command.
CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
EXPORTING
I_INTERFACE_CHECK = ' '
I_BYPASSING_BUFFER = ' '
I_BUFFER_ACTIVE = ' '
i_callback_program = sy-repid
I_CALLBACK_PF_STATUS_SET = ' '
i_callback_user_command = t_callback_main_user_command
i_callback_top_of_page = 'TOP-OF-PAGE'
I_CALLBACK_HTML_TOP_OF_PAGE = ' '
I_CALLBACK_HTML_END_OF_LIST = ' '
I_STRUCTURE_NAME =
I_BACKGROUND_ID = ' '
I_GRID_TITLE =
I_GRID_SETTINGS =
is_layout = w_layout
it_fieldcat = t_fieldcat
IT_EXCLUDING =
IT_SPECIAL_GROUPS =
IT_SORT =
IT_FILTER =
IS_SEL_HIDE =
I_DEFAULT = 'X'
i_save = gc_save
IS_VARIANT =
IT_EVENTS =
IT_EVENT_EXIT =
IS_PRINT =
IS_REPREP_ID =
I_SCREEN_START_COLUMN = 0
I_SCREEN_START_LINE = 0
I_SCREEN_END_COLUMN = 0
I_SCREEN_END_LINE = 0
I_HTML_HEIGHT_TOP = 0
I_HTML_HEIGHT_END = 0
IT_ALV_GRAPHICS =
IT_HYPERLINK =
IT_ADD_FIELDCAT =
IT_EXCEPT_QINFO =
IR_SALV_FULLSCREEN_ADAPTER =
IMPORTING
E_EXIT_CAUSED_BY_CALLER =
ES_EXIT_CAUSED_BY_USER =
TABLES
t_outtab = it_out
EXCEPTIONS
PROGRAM_ERROR = 1
OTHERS = 2
ENDIF. -
Hi all,
I am using ALV oops for displaying table.
CL_GUI_ALV_GRID->set_table_for_first_display.
I have cretaed an Custom Container for this.
Now scenario is like, First i have to display normal classical report when user double click on classical report
it will show alv grid on other screen depending on the row of report user clicks i am picking data and showing it on other screen as ALV grid.
First time its showing correct data when i press back on ALV grid screen and came back on report screen and select other row and double click its not showing anything ..
Please help.
Its required very urgently by client.
Thanks in advance..
HarshHi,
Check whether the internal table in which you are passing data to the grid has the correct data.
Do not call the method set_table_for_first_display once again.
Instead call the method REFRESH_TABLE_DISPLAY.
Call the method SET_TABLE_FOR_FIRST_DISPLAY only once when the ALV grid object is created.
Call the method flush of the class cl_gui_cfw in the PBO after the grid is displayed; after the method SET_TABLE_FOR_FIRST_DISPLAY
Check if this works.
Regards,
Ankur Parab -
How to display a field that has more than 136 char length in ALV GRID
Hi Experts,
I have an issue and need to solve ASAP.
I want to display a text of length 400 character in a particular column in ALV GRID DISPLAY. After executing the report it is displaying only 136 length char in the output and when I download the report to an excel it is showing only 255 characters, but my field length is almost 400 char and want to display in the report output.
I checked in SDN and didnt get any answers which will solve this.
Please help me to complete this issue.
Thanks
RetheeshCurrently I'm in a same problem with you.
And this is what I found
Size of data fields: While the list-based ALVList can display only tables of up to 90 columns, the control-based *ALVGrid and ALVFullscreen have a limitation of 128 characters per data cell.*
So it means that maximum for alv grid is only 128.
Please refer to this documentation
[https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/4544e790-0201-0010-c29c-e46c389f5a96]
you can find the statement above in page 5.
Please let me know if you have another solution, because I would like to see it too.
Thanks
Regards
Hadi -
Hi experts.....
I like to know How to create Editable ALV Grid using Class...
Also i like to to know how to add The contains to Z-Table...
Whether we can delete ALV grid contents........
...Thanks
..AshishHello Ashish
You may want to have a look at thread Select Row in OO-ALV programmatically
Regards
Uwe
Maybe you are looking for
-
How to call a class file in a jsp without deploying anything in j2ee
Hi, I am new in J2EE. I have some jsps, which I configured using web.properties(documentroot=c:/jsp/). I am able to get those pages by the web browser. I have some import statements in some jsps, now I am trying to access those page but it is failing
-
Hi all , in my communication channel when i press message id it is just opening audit log only not showing any other details like payload msg is processed regadrs sivaramaraju
-
Reverse the sort output for autofeed copying??
is there a way to "reverse" the output for copying when using the autofeed tray? i sometimes copy 20+ page documents and every time i do this i get the first page face up and then the second page comes out face up and then the third so that i have to
-
Hi ! Please help me in solving this issue , i am stuck up with an insertion querry.. my constraint is create table STG_PLNT_PUR_ORD SOURCE_SYSTEM VARCHAR2(30) not null, TYPE_LOOKUP_CODE VARCHAR2(25), PO_NUM VARCHAR2(20) not null, LINE_NUM NUMBER not
-
Break implementation of Sales&Distribution FROM Production into phases
I have found this forum very helpful and responsive. Thanks for all the help. Due to the requirement of getting the ecommerce site up fast, is it possible to just implement: Sales Distribution side of business one 2007A APART From the Production MRP