AMFPHP 5.0Mb data timeout error

Hi,
im using amfphp and have 5Mb data, in 500 rows.
But im receiveing timeout error.
I have some 500Kb on datagrid and the rest on RichTextEditor.
What can i do to receive this without error? Is it possible to call the some function a lot of times and populating the datagrid in 10 rows each time, for example?
Thanks for help.

The parameter log_archive_config is wrongly configured on the standby database.
Add the database unique name (db_unique_name) of the primary database to the log_archive_config of the standby database
On the standby, your log_archive_config should be something like
log_archive_config='DG_CONFIG=(icts001,sms)';
cmadiam82     
Handle:  cmadiam82   
Status Level:  Newbie 
Registered:  Feb 28, 2010 
Total Posts:  36 
Total Questions:  13 (11 unresolved)  It is sad to see that forums is of no help to you. :(
Please mark the threads as answered if you have got a solution and keep the forums clean. If not, then reply to your questions so that you would get back an answer rather than keeping it as unanswered.

Similar Messages

  • Planning Data Pull process failed with timeout error

    Hi Experts,
    Version: Oracle apps 11.5.10.2
    Issue: Planning Data Pull process failed with timeout error
    message in the log file as follows,
    The Request id : 90018907 has Phase : COMPLETE and Status: ERROR
    Concurrent Message : Timeout error.
    There is an Unknown error in the Worker.
    Planning Data Pull process failed.
    +-------------------------------------
    Please advice what could be the problem. I submitted, standard data collection programs with 900 mins and 8 workers.
    Refresh Collection Snapshot completed without any issue

    Please see these docs.
    Data Collection Fails Because Of Time Out Timeout error [ID 339968.1]
    OPM-ASCP: Data Collection Timeout Error [ID 601539.1]
    STD COLLECTION FAILING AT PLANNING DATA PULL WITH TIMEOUT ERROR [ID 978472.1]
    Data Collections is Failing - All Errors - First Diagnostic Steps [ID 207644.1]
    Troubleshooting Errors with ATP/Planning Data Collections [ID 1227255.1]
    MSCPDC PLANNING ODS LOAD ERRORS WITH TIMEOUT ERROR - POOR PERFORMANCE [ID 417633.1]
    Thanks,
    Hussein

  • Getting timeout error while updating a record from c#

    Hi,
    I have around 30k records in a tables. When I update that record inside the Transaction (Enterprise Data Library, c#) , it takes long time and throws timeout error.
    But I am able to update the same record via Toad.
    In the morning I tried same updating the record, it works without any change in the code or script.+
    is it due table lock or db related issue? please adivse, how to resolve if occurs again.
    anand

    Code:
    private static void Save()
    using (DBTransactionManager dbTransactionManager = new DBTransactionManager())
    try
    DataTableDAL.Instance.ExecuteDML("Update Voyage SET BallastBonus = 30000 WHERE ID = 'AE53B610BEA743EC8AFBAED0C8349BF8';");
    //commit database
    dbTransactionManager.Commit();
    catch
    dbTransactionManager.RollBack();
    throw;
    Table
    Column Name     ID     Pk     Null?     Data Type     Default     Histogram     Encryption Alg     Salt
    ID     1     1     N     NVARCHAR2 (32)          None          
    CALCNUMBER     2          N     NUMBER (10)          None          
    CURRENCYID     3          N     NVARCHAR2 (32)          Frequency          
    CALCTYPE     4          N     NUMBER (5)          Frequency          
    ESTIMATEDESCRIPTION     5          Y     NVARCHAR2 (200)          None          
    ESTIMATEGROUPDESCRIPTION     6          Y     NVARCHAR2 (200)          None          
    BALLASTBONUS     7          Y     NUMBER (12,2)          None          
    BALLASTBONUSCOMMPCT     8          Y     NUMBER (6,3)          None          
    ISESTIMATE     9          N     NUMBER (1)          None          
    ADDITIONALSTEAMVALUE     10          Y     NUMBER (8,4)          None          
    ISADDITIONALSTEAMPCT     11          Y     NUMBER (1)          None          
    ADDITIONALPORTVALUE     12          Y     NUMBER (8,4)          None          
    ISADDITIONALPORTPCT     13          Y     NUMBER (1)          None          
    CREATEDBY     14          N     NVARCHAR2 (32)          Frequency          
    CREATEDDATE     15          N     DATE          None          
    UPDATEDBY     16          Y     NVARCHAR2 (32)          None          
    UPDATEDDATE     17          Y     DATE          None          
    LUMPSUMCARGOCOST     18          Y     NUMBER (1)          None          
    BUNKERPRICEMETHOD     19          Y     VARCHAR2 (30 Byte)          None          
    INCCONTCALCRESULT     20          Y     NUMBER (1)          None          
    FINAL_EST     21          Y     NUMBER          None          
    SPOT_VOYAGE     22          Y     NUMBER (1)          None          
    ISRUNCOSTEDIT     23          Y     NUMBER (1)          None          
    Index
    Table doesnt have any index, except primary key index.
    Total Records
    35,000
    Hope this input might sufficient to help me.

  • Open socket timeout error

    Sometime I can write to the local shared variable through data socket. But sometime cannot. Even though, I still can read/write through shared variable monitor.
    The error is in the open socket, said connect to peer timeout. I set timeout to 10s or left blank both not work.
    I am using 8.2.1 on vista. The computer has 2 lan ports.
    I met almost same case long time ago. I solved it by diable NETBIOS and one of the lan port.
    This time, I disabled netbios already. But in vista, seems not able to disable the other lan port.
    Any suggestion?

    hi turbot,
    I had same problem of timeout error.just check if system Firewall is on or off if it is on then make it off and then run the program.i don't know how much this will help you,it helped me.
    GAK
    Gaurav k
    CLD Certified !!!!!
    Do not forget to Mark solution and to give Kudo if problem is solved.

  • Getting timeout error while executing my report

    Hi experts,
    I need to get data from a Ztable which is having more than 64 millions of records. That query itself is taking more than 20 min to execute. I have used package size while retrieving tha data but still taking same time to execute, Giving me the TIMEOUT error .
    Provide some suggetions to use different types of SELECT quries that can be used to improve the performance.
    Thanks & Regards,
    Bhanu

    Hi ,
    I am working as an abaper for Service Management module.
    I need to show the prmise details inthe output of alv. Before that i need to get the meter reading details and need to do some calculations, by which i need to show idle one (Here only i need to hit a ZTABLE which is having more than 64 million records). For that idle premise user can select multiple pemises by using check boxes and can create notification by pressing a pushbutton 'CREATE IS NOTIFICATION' which exist on the application toolbar . So i can not run this report in background.
    Thanks & regards,
    Bhanu.

  • Timeout error in ECC "INTERNAL.CLIENT_RECEIVE_FAILED Error while receiving by HTTP (error code: 402 , error text: ICM_HTTP_TIMEOUT)"

    Dear Experts,
    I am very critical situation due to this timeout error in ECC, please help me as much as you can. Go-live date is very near, but I am not getting any clue why this error is occurring. our ECC system is EHP 4, and PI is dual stack 7.4
    My scenario is synchronous ABAP proxy to HTTP_AAE. request is triggering from ECC via proxy and reaching to third party (bank) through PI, I am reviving the response back in PI from bank. But from PI to ECC the response is not reaching. So in ECC after the defined Timeout limit its getting timed out.
    I have tried everything by increasing the timeout in ECC more than 15 minutes in HTTP_TIMEOUT under SXMB_adm in ECC, but nothing worked, even if I am increasing for half an hour then also its getting timeout after half an hour.
    response from bank to PI is coming within 30 to 40 seconds, but PI is not sending the response back to ECC.
    This is classical scenario, and I have checked the trace via SXMB_Moni in PI as well as in ECC, in ECC its showing the timeout error, but in PI i did not see any trace for this error.
    I have read many thread on SCN for the same error, and everywhere it has been suggested to increase the timeout, and I have tired that, it didn't help me.
    All ABAP proxy configuration has been done as follows.
    RFC destinations in ECC
    LCRSAPRFC(TCP/IP)
    SAPSLDAPI ((TCP/IP))
    G type destination to path "/sap/xi/engine?type=entry"
    G type destination SAP_PROXY_ESR to path "/rep"
    All the destination connection test is working fine.
    but i have a doubt on G type destination(AAE_XDJ) to path  "/sap/xi/engine?type=entry" which is returns the status code 500 with message "Empty HTTP request received", is it ok with 500 ?
    Configuration in ECC Integration Engine configuration is as follows
    Questions
    How the message gets pushed to ECC from PI, once the message received in PI, I believe by G type RFC destination on path  "/sap/xi/engine?type=entry" , please clarify.
    How to trace this, if message is not getting pushed to ECC, I mean I have checked the trace in PI XSMB_MONI, but didn't get anything for this error. In ECC SXMB_moni only I am able to the timeout error.
    Please expert help me as soon as you can, this error really effecting me badly in front of management
    Thanks,
    Farhan

    Hi Hareesh,
    I configured the scenario based on ICO, and again I received the same timeout error in ECC.
    I am really sick with this error, and I have raised the OSS message to SAP. Meanwhile I just want to double check my entire configuration with you. Please see the below configuration (for classical) for ABAP proxy to HTTP_AAE, and let me know if anything is wrong.
    Request structure (ECC->PI->Bank)
    <?xml version='1.0' ?>
    <PaymentInfoMessage>
    <PaymentInfoRequest>
    <CompanyCode>Partner01</CompanyCode>
    <BankCode>BSFRSARI</BankCode>
    <StartDate>2006-07-09T00:00:00</StartDate>
    <EndDate>2006-07-09T00:00:00</EndDate>
    <TransactionType>940</TransactionType>
    </PaymentInfoRequest>
    </PaymentInfoMessage>
    Response Structure (Bank->PI->ECC)
    <?xml version="1.0"?>
    <PaymentInfoMessageResponse>
    <PaymentInfoResponse>
        <TransactionType>940</TransactionType>
        <SequenceNum>1</SequenceNum>
        <ReceiptTime>2002-01-02T18:01:00</ReceiptTime>
        <ProcessStatus>1</ProcessStatus>
        <Comment>No Comment</Comment>
        <TransactionData>:20:MT940-1007200601
    :25:3210000079901
    :28C:190/0001
    </TransactionData>
        <CompanyCode>PARTNER01</CompanyCode>
    </PaymentInfoResponse>
    <StatusCode>OK</StatusCode>
    <StatusDetail>OK</StatusDetail>
    <ResponseItemCount>2</ResponseItemCount>
    </PaymentInfoMessageResponse>
    ESR Configuration
    Please see the below screenshot for ESR config. I have created 4 data types, 4 message types, 2 Service interface (synchronous), 2 mapping and one operation mapping.
    I just want to clarify about selecting the Request and response message type in inbound and outbound service interface.
    <?xml version='1.0' ?>
    <PaymentInfoMessage>
    <PaymentInfoRequest>
    <CompanyCode>Partner01</CompanyCode>
    <BankCode>BSFRSARI</BankCode>
    <StartDate>2006-07-09T00:00:00</StartDate>
    <EndDate>2006-07-09T00:00:00</EndDate>
    <TransactionType>940</TransactionType>
    </PaymentInfoRequest>
    </PaymentInfoMessage>
    Response Structure (Bank->PI->ECC)
    <?xml version="1.0"?>
    <PaymentInfoMessageResponse>
    <PaymentInfoResponse>
        <TransactionType>940</TransactionType>
        <SequenceNum>1</SequenceNum>
        <ReceiptTime>2002-01-02T18:01:00</ReceiptTime>
        <ProcessStatus>1</ProcessStatus>
        <Comment>No Comment</Comment>
        <TransactionData>:20:MT940-1007200601
    :25:3210000079901
    :28C:190/0001
    </TransactionData>
        <CompanyCode>PARTNER01</CompanyCode>
    </PaymentInfoResponse>
    <StatusCode>OK</StatusCode>
    <StatusDetail>OK</StatusDetail>
    <ResponseItemCount>2</ResponseItemCount>
    </PaymentInfoMessageResponse>
    ESR Configuration
    I have simply created 2 data types for requests(ECC->PI->Bank) and did one to one mapping. Similarly for response(Bank->PI->ECC) 2 data types, one to one mapping for this as well.
    But I just want to clarify about selecting the Request and response message type in inbound and outbound service interface. please explain me this for synchronous interface.
    Please see the below structure from ESR and inbound and Outbound service and let me know if the selection of Request and response message types is correct or not.
    OutBound service interface
    Inbound service interface
    Thanks,
    Farhan

  • All of a sudden I cannot Forward emails in TB 31.1.2 - I get SMTP timeout error

    And I've tried everything. Shutdown Emsisoft virus prot., turned off firewall, got into Verizon router (btw, I'm going right into the Verizon router-not thru a switch), no port forwarding, even tried to forward an email in Safe mode in Win 8.1 x64. This just happened. I can Write an email OK (i.e., from scratch), but just forwarding, even a small text message won't forward. I even installed an older version of TB. HELP! HELP!
    I either get the SMTP timeout error or I get "check your email and messaging settings." My wife has the exact same setup in TB 31.1.2 but she uses Win 7 x86. -gg

    This has been reported as [https://bugzilla.mozilla.org/show_bug.cgi?id=1060901 Bug #1060901]. If you have an account on Bugzilla, please consider voting for that issue.
    Several other people have sent in the same support request as you, noting this happened after they upgraded to version 31.1.
    The exact error message is: XXXX is not a valid e-mail address because it is not of the form user@host. You must correct it before sending the e-mail.
    '''This happens in Thunderbird 31.1.0 when your mailing list description includes several words separated by spaces.'''
    Although not ideal, these workarounds should let you use your mailing lists until a proper fix is implemented:
    * While composing an email open the address book and select the list you are trying to send to, highlight all the names in the list and drag them to the To: box. This uses your existing data without modifying it.
    * Replacing the blanks " " between the words in such lists' descriptions with an underscore "_". This requires modifying your mailing list(s) description(s).
    '''About automatic updates'''
    Automatic updates are the default in Windows.
    You can [https://support.mozilla.org/en-US/kb/configuration-options-updates?esab=a&s=automatic+updates&r=1&as=s customize such behavior], however, it's under '''Tools > Options > Advanced > Update'''.
    My suggestion would be to set it to '''Check for updates, but let me choose wether to install them.''', specially if you depend on email for critical / important business or personal matters.

  • Timeout errors when using high speed camera.

    Hi all.
    I'm currently trying to capture images using a Mikrotron EoSens MC1363 camera at high frame rates >500fps. The issue arises when the region of interest (ROI) is decreased in the microtron software (of which screenshots are attached). The ROI must be dropped in order to increase the fps. When MAX is opened and configured to match the camera settings, and grab is initiated, the timeout error occurs. I've attached screenshots of the mikrotron software, max settings, the error and PC used. The OS is windows 7 64 bit. We use the camera config file for the mono version of the camera which i've been informed will cross over to satisfy the colour version we use. Any questions feel free to ask. Thanks.
    Attachments:
    errors.docx ‏3016 KB
    997-EoSens 3CL-MC1362-Manual.pdf ‏1209 KB

    Hi Dom.
    As you said the maximum frame rate with the ROI set to 1280 x 1024 is 505fps but according to the general information for the camera series:
    The Mikrotron EoSens camera series features extremely sensitive high-speed
    CMOS sensors available in monochrome or in colour with a resolution of 1280 x
    1024 pixels and capture rates of 110 or 500 frames per second. Depending on
    the model the image data is transferred in 8 or 10 bits via either CameraLink
    (Base, Medium or Full) or Gigabit Ethernet.The region of interest (ROI) can be
    freely selected, and the cameras can achieve even higher capture rates up to
    120,000 fps when the ROI is reduced
    Therefore it was my thought that by reducing the width of the ROI increased frame rates may be reached. Realistically we're looking for as high frame rates as possible so that the camera has capability to pass between projects. Currently the moving object enters and leaves the ROI within a 4 frame window, so frame rates of up to 1000fps would generate more data. Naturally, a point will come where the data cannot be physically written as fast as it is generated (>600MBps). Therefore it would be useful to get a handle onto why the error occurs as well as methods to fix it. Hopefully the problem is being discussed between NI and Mikrotron and we may have some answers in the near future.

  • CAN Connection timeout error

    I am currently trying to connect to a third party ECU via the ECU toolkit. I am running V8.2 of labview and V2.1 of the toolkit with a series 2 hi-speed PCI NI-CAN card. When I try to connect to the ECU I get a timeout error "-301096: Timeout ocurred while waiting for response from slave device".
    When the A2L file is initially loaded, the individual characteristic and measurement tables load without a problem but the CAN settings do not load. As a result, I use the MC set property vi to manually set CRO id, DTO id, baud rate, byte order and command byte order (after using the hex string to number conversion vi). I also manually set the seedkey dll's but I don't think that the program is getting that far since I have also tried putting in non-existant seedkey dll's and this has no effect.
    I have tried increasing the timeout by factors of 10 and 100 by using the "Set Prop Timing factor" Vi as this is given as a solution to problems with the series 1 boards but this does not help.
    I am using extended (29 bit) identifiers and in one of the supplied examples, there is a multiplication by 20 million and I have also tried this (it changes the CRO id from 0CCCCCCC to 2CCCCCCC for example).
    I have tried using an XCP type connection but I get the same error.
    I have checked the physical state of the CAN bus by looking at the CAN0 channel in MAX and the bus monitor reports no errors and seems to have 3 distinct messages that keep repeating. When in 'listen only mode', the number of repeated messages returns to 1.
    I have included here an excerpt from the A2L file I am using and I have been manually setting up the ECU properties as follows:
    connection type CCP:CAN0
    baud 250000
    CRO id: 0CCCCCCC
    DTO id: 0DDDDDDD
    Station address: 100
    Byte order/cmd byte order: 1
    Is there a way to tell if the Exchange_id function in the CCP protocol is being called? It seems to me that it must be falling over somewhere in here as this is needed in order to compute a correct seedkey for any unlocking of parameters. I would be grateful of any suggestions to help get this up and running.
    Note that I have changed the proprietary A2L information.
    Dan
    Attachments:
    exampleCAN1.txt ‏1 KB

    Hi Graham,
    I tried starting off from a completely blank A2L and added connection parameters one at a time until I was sure each line was being read correctly by the toolkit parser. This seemed to work fine but the connection would open, try to unlock ECU resources and then return an error that the resources were unavailable and I should try a different seedkey.dll. I captured the CAN frames that were being sent via a second CAN card to look at the exact command sequence. I then extracted the seed data from the get seed reply frame and used a call library node function to call the seedkey.dll. This returned a different key to the one that was being sent in the unlock command so I could only assume that the toolkit is not calling the seedkey correctly somehow but since this is all hidden in a dll, I could not look at the exact mechanics to see what was going wrong. I then built a  VI using the frame API stuff that comes with the NI-CAN drivers cd to manually send the the frames required to connect then get seed. I use the same call library node function to call the seedkey.dll and then build another frame with the returned key. This all seems to work fine and I have an unlocked ECU. Unfortunately since I did all this with the frame API, there was no way to subsequently use the toolkit vi's as they are built around the channel API which is apparently incompatible. Feeling completely frustrated with the non-functional toolkit and having logged a couple of tech help requests with NI I have given up on the tooklit altogether, built my own A2L parser and I am almost finished with the communications interface using the frame APIs. Thanks anyway,
    Dan

  • Select query - timeout error

    hi experts,
    I have written a pgm where i need to select records from BSAD table. This table has about 10 key fields. But according to my requirement, i can pass only 2 key fields to the table and have to fetch records from this table.  But it goes to dump (timout error) in BSAD select query.
    So  i have used PACKAGE SIZE 20 and tried to fetch only 20 records at a time from the table. But still, it takes lot of time in fetching records from BSAD table.
    Pls tell me what is the solution to avoid timeout error and how to fetch the records quickly.
    Regards,
    Shanthi

    I hope that your " two fields"  are BUKRS and KUNNR.  
    Consider this:  If I can't supply a value for the first field (after mandt), then the second, etc., the select is going to run FOREVER.  I think that, if you used ST05 and explained the BSAD open, you would see the problem. I'm guessing that you're not supplying a value for BUKRS, etc., and thereby causing a full table scan.   Or you may have supplied NOT operators in the where clause or included an order by statement.  Current ABAP CHECK tools (like SLIN or SCID) should point out problems in the where statement also...
    May I suggest utilizing SE11 and looking at BS* tables to see if there is an alternative data source where you can supply an EQ value for the first few fields (at least) of the index?  Or, post psuedocode so that the forum users can help you out.

  • Macro Timeout Error- MS Access Web App 2013

    Hello everyone,
    I have a MS Access Web App built with a lot of different tables and everything works fine. I have this one table with a number of fields (70 different fields), and some of them are lookups to other tables or a dropdown menu. In our company
    we were using only SharePoint earlier and now we are migrating to access web app. I need to copy or import all the data that we had previously into that one table and then be able to do different types of data manipulations. 
    I have created a data macro to copy all the records even the lookups (a separate thread is available if anyone is dealing with that problem). When I try to copy say 500 records this works fine. But, when I try to copy more records it throws me a timeout
    error. It only works for 60 seconds and then it stops and throws an error. Is there a way I can increase the timeout? Or has anyone else faced the same problem?
    Please advise.
    Thanks in advance.

    The recommended way is to use an Access desktop database and connect to the Azure database behind your App. The firewall and connection information is under File> Info > Connections.
    You can then have linked tables to your SharePoint lists and to your Azure tables, and write append queries to copy the data over.
    -Tom. Microsoft Access MVP

  • Timeout error (code 6101) for acquisition from MODBUS instrument

    I am experiencing a problem which other users have reported, but for which little useful information has been posted:
    I am trying to acquire data from an instrument using MODBUS RTU protocol.  The code works as desired for a while, but will intermittently stop executing and give a timeout error, code 6101.  This code seems to be associated with the MB Serial Master Query sub VI.  In the past, I was getting this error as a result of RF noise corrupting the signal in the USB connection to the instrument.  Removing the USB cable from the noisy environment eliminated the problem.  I am now having the problem with an RS 485 line in the noisy environment, which should be very stable in noisy environemnts. 
    My question:  is there a coding trick i can use to reconnect in the event that a corrupt signal occurrs (or some other problem which results in the intermittent appearence of the error 6101)?   I've increased the timeout value on the MB Serial Master Query sub vi, but this hasn't helped.  Any input is appreciated.  In case it's useful, I've posted a simple version of code which generates the problem. 
    Thanks,
    Paul   
    Attachments:
    Floating point 1.12.vi ‏24 KB
    timeout error1.JPG ‏31 KB

    Thanks for your input, Ravens Fan.  I am indeed getting a popup error message with the timeout.  I agree that putting the MODBUS read in its own loop would solve the problem.  However, I'm struggling with trying to figure out how to actually do this.  Should I put the read in a case structure or a while loop?  How do I go about looping back to re-execute the read statement?  I think so called "state machine architecture" seems to be where I should be going. Some example code would be greatly appreciated. 
    paul  

  • Lock timeout error trying to create a partition

    I'm getting a lock timeout error attempting to partition a large BSEG table.  I have done this before successfully on other tables but for some reason this keeps failing with the following error:
    Could not execute 'ALTER TABLE "OURSCHEMA"."BSEG" PARTITION BY RANGE (GJAHR) (PARTITION 1 <= VALUES < 1999, PARTITION ...' in 2:30:35.927 hours . SAP DBTech JDBC: [131]: transaction rolled back by lock wait timeout: Lock timeout occurs while waiting TABLE_LOCK of mode EXCLUSIVE(TRANSACTION_ID=128, UPDATE_TRANSACTION_ID=2123074)
    NOTE: We have SUSPENDED the replication of BSEG while this partition is happening.
    Anybody experience this problem?
    Thanks,
    -Patrick

    Hi,
    Try partitoning the BSEG table from SLT using the t-code IUUC_REPL_CONTENT - Maintaining the replication settings.
    Select the schema, select BSEG, go to 'Edit settings' and enter the script in the 'Partition Command' of BSED.
    eg,: PARTITION BY HASH(GJAHR) PARTITIONS 5
    Try replicating now from Data Prov.
    Hope it works...
    Regards,
    Papil

  • Script timeouts (Error #1502) and WebService component

    Hello Flex community,
    I am getting a script timeout (error #1502) when I am calling a SharePoint Web Service (CopyIntoItems) when trying to upload large files (greater than 40 MB).
    The error does not occur when using the Web Service for smaller files. The large files can be uploaded directly to SharePoint using the web interface therefore it is not a back-end SharePoint issue.
    I believe the issue has to do with the logic in the WebService Flex component, however I am not sure how to optimize it and I cannot break down the file into smaller chunks as it needs to be together in order to upload with the SharePoint field information.
    Anyone have any ideas on how I can resolve this issue?
    Thanks,
    Mauricio

    I can't say exactly what is big binding because it depends on combination of factors: how fast your machine is, how big the Excel model is, how many components you have etc. Generally if you have bindings with several thousand cells it's going to cause the timeout problem. The problem is that we use Flash player in the application, and if some operation takes longer than a minute it times out. So, if getting data from the big bindings took too long, the flash player stops the operation and you have this timeout error.
    You see the timeout error only if you have debug version of Flash player installed. If you have release version installed, you don't see any erors, but you notice strange things, for example selecting component on the canvas does not cause property sheet to display. Release version of Flash is faster, so you can try to remove debug flash player and install release and there is chance that it will work.
    FP1 version is going to include some optimisations to reduce this problem and allow working with larger files.
    Margaret

  • TIMEOUT error from adstrtal.sh -- even after made Guest user password same

    I have migrated E-bus Database from HPTru64 to SunSolaris (Still Object differences are there).
    when I try to start application I got TimeOUT error.
    1)I made GUEST password same in <Context>.xml & $FND_TOP/11.5.0/secure/*.dbc file to ORACLE
    2)ran adautocfg.sh on all apps nodes
    still I get same error...
    SQL> SELECT fnd_web_sec.validate_login('GUEST','ORACLE') FROM dual;
    FND_WEB_SEC.VALIDATE_LOGIN('GUEST','ORACLE')
    N
    SQL>

    Sawwan,
    I got below error...
    I am in the process of migration, I may not be able to use OAM unless I start the application..
    ====================
    SQL> @afgstusr.sql
    PL/SQL procedure successfully completed.
    ERROR: The Profile "Guest User Password" is not set correctly, the current
    value is "GUEST/ORACLE" and failed FND user validation.
    Oracle Applications requires a "GUEST" user account for special restricted
    access functions. The "<GUEST User Name>/<Password>" is stored in the
    profile option "Guest User Password" for Applications program use. In this
    instance the profile option is not set, or does not represent a valid
    User_name/Password combination.
    CORRECTIVE ACTION: The profile needs to be set to a valid User_name/Password
    combination, preferably the combination for the seeded user account "GUEST".
    The profile can be set using the Oracle Forms Interface and the System
    Administrator Responsibility.
    Navigate -> Profile -> System -> Query Site level profile:
    "Guest User Password"
    Alternatively, if the profile value shown above is defined and set to what
    you think should be the correct value, you may need to reset the GUEST user
    account password from the Oracle Forms Interface. Again using the System
    Administrator Responsibility.
    Navigate -> Security -> User -> Define -> Query "User Name":
    Type a temporary password in the "Password" field -> hit the Tab Key
    and confirm the password ... Then log in to Oracle Applications Forms
    Interface as this user and change the password, when prompted to do so,
    to match the value set in the "Guest User Password" profile.
    Finally if the Oracle Forms Interface is not available for some reason you
    can use SQL*Plus and the Applications API - FND_PROFILE.SAVE(). You can use
    the file that generated this message (FND_TOP/patch/115/sql/afgstusr.sql) as
    an example of how to code this function. Set the value to a known good
    User_name/Password combination. Remember to go back and properly set up
    a default GUEST account and to synchronize the profile after your upgrade is
    complete using the appropriate steps shown above.
    DECLARE
    ERROR at line 1:
    ORA-06510: PL/SQL: unhandled user-defined exception
    ORA-06512: at line 15
    Disconnected from Oracle Database 10g Enterprise Edition Release 10.2.0.4.0 - 64bit Production
    With the Partitioning, OLAP, Data Mining and Real Application Testing options
    $

Maybe you are looking for

  • Seperate include directory for i486-mingw32 cross-compiler toolchain

    I've installed the mingw32 cross-compiler. I noticed that when using this compiler, a seperate, non-standard include directory is used. So instead of copying all of the dependencies headers to compile the software, is there an easier way of including

  • Template/Page size questions

    Hey guys, I will explain what I am trying to do then maybe someone can walk me through it. We have a advertisement flyer type thing that I need to come up with an ad for, each ad is 4x3. I need to come up with an ad front and back, and figured that P

  • Editing pages files in Linux

    I have a bit of a problem. I have several files as .pages documents and I need to edit these in Linux. (Kubuntu 9.10, fully updated) now I can save the .pages files as .odt and open them in OpenOffice.Org but, I have some markup that open document te

  • How do I return a device licence to my deployment pool?

    How do I return a device license to my deployment pool. I have created a package using CCP and deployed it to a test machine but now I need to return the license to my deployment pool. There is no obvious way of doing this via the deployed app or via

  • PP CS4 color key not working