Ask the Expert: Cisco UCS Troubleshooting Boot from SAN with FC and iSCSI

Welcome to this Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about Cisco UCS Troubleshooting Boot from SAN with FC and iSCSI with Vishal Mehta and Manuel Velasco.
The current industry trend is to use SAN (FC/FCoE/iSCSI) for booting operating systems instead of using local storage.
Boot from SAN offers many benefits, including:
Server without local storage can run cooler and use the extra space for other components.
Redeployment of servers caused by hardware failures becomes easier with boot from SAN servers.
SAN storage allows the administrator to use storage more efficiently.
Boot from SAN offers reliability because the user can access the boot disk through multiple paths, which protects the disk from being a single point of failure.
Cisco UCS takes away much of the complexity with its service profiles and associated boot policies to make boot from SAN deployment an easy task.
Vishal Mehta is a customer support engineer for Cisco’s Data Center Server Virtualization TAC team based in San Jose, California. He has been working in the TAC for the past three years with a primary focus on data center technologies such as Cisco Nexus 5000, Cisco UCS, Cisco Nexus 1000v, and virtualization. He has presented at Cisco Live in Orlando 2013 and will present at Cisco Live Milan 2014 (BRKCOM-3003, BRKDCT-3444, and LABDCT-2333). He holds a master’s degree from Rutgers University in electrical and computer engineering and has CCIE certification (number 37139) in routing and switching and service provider.
Manuel Velasco is a customer support engineer for Cisco’s Data Center Server Virtualization TAC team based in San Jose, California. He has been working in the TAC for the past three years with a primary focus on data center technologies such as Cisco UCS, Cisco Nexus 1000v, and virtualization. Manuel holds a master’s degree in electrical engineering from California Polytechnic State University (Cal Poly) and VMware VCP and CCNA certifications.
Remember to use the rating system to let Vishal and Manuel know if you have received an adequate response. 
Because of the volume expected during this event, our experts might not be able to answer every question. Remember that you can continue the conversation in the Data Center community, under subcommunity Unified Computing, shortly after the event. This event lasts through April 25, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

Hello Evan
Thank you for asking this question. Most common TAC cases that we have seen on Boot-from-SAN failures are due to misconfiguration.
So our methodology is to verify configuration and troubleshoot from server to storage switches to storage array.
Before diving into troubleshooting, make sure there is clear understanding of this topology. This is very vital with any troubleshooting scenario. Know what devices you have and how they are connected, how many paths are connected, Switch/NPV mode and so on.
Always try to troubleshoot one path at a time and verify that the setup is in complaint with the SW/HW interop matrix tested by Cisco.
Step 1: Check at server
a. make sure to have uniform firmware version across all components of UCS
b. Verify if VSAN is created and FC uplinks are configured correctly. VSANs/FCoE-vlan should be unique per fabric
c. Verify at service profile level for configuration of vHBAs - vHBA per Fabric should have unique VSAN number
Note down the WWPN of your vhba. This will be needed in step 2 for zoning on the SAN switch and step 3 for LUN masking on the storage array.
d. verify if Boot Policy of the service profile is configured to Boot From SAN - the Boot Order and its parameters such as Lun ID and WWN are extremely important
e. finally at UCS CLI - verify the flogi of vHBAs (for NPV mode, command is (from nxos) – show npv flogi-table)
Step 2: Check at Storage Switch
a. Verify the mode (by default UCS is in FC end-host mode, so storage switch has to be in NPIV mode; unless UCS is in FC Switch mode)
b. Verify the switch port connecting to UCS is UP as an F-Port and is configured for correct VSAN
c. Check if both the initiator (Server) and the target (Storage) are logged into the fabric switch (command for MDS/N5k - show flogi database vsan X)
d. Once confirmed that initiator and target devices are logged into the fabric, query the name server to see if they have registered themselves correctly. (command - show fcns database vsan X)
e. Most important configuration to check on Storage Switch is the zoning
Zoning is basically access control for our initiator to  targets. Most common design is to configure one zone per initiator and target.
Zoning will require you to configure a zone, put that zone into your current zonset, then ACTIVATE it. (command - show zoneset active vsan X)
Step 3: Check at Storage Array
When the Storage array logs into the SAN fabric, it queries the name server to see which devices it can communicate.
LUN masking is crucial step on Storage Array which gives particular host (server) access to specific LUN
Assuming that both the storage and initiator have FLOGI’d into the fabric and the zoning is correct (as per Step 1 & 2)
Following needs to be verified at Storage Array level
a. Are the wwpn of the initiators (vhba of the hosts) visible on the storage array?
b. If above is yes then Is LUN Masking applied?
c. What LUN number is presented to the host - this is the number that we see in Lun ID on the 'Boot Order' of Step 1
Below document has details and troubleshooting outputs:
http://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucs-b-series-blade-servers/115764-ucs-san-tshoot-00.html
Hope this answers your question.
Thanks,
Vishal 

Similar Messages

  • Ask the Expert: Cisco UCS B-Series Latest Version New Features

    Welcome to this Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about the Cisco UCS Manager 2.2(1) release, which delivers several important features and major enhancements in the fabric, compute, and operational areas. Some of these features include fabric scaling, VLANs, VIFs, IGMP groups, network endpoints, unidirectional link detection (UDLD) support, support for virtual machine queue (VMQ), direct connect C-Series to FI without FEX, direct KVM access, and several other features.
    Teclus Dsouza is a customer support engineer from the Server Virtualization team at the Cisco Technical Assistance Center in Bangalore, India. He has over 15 years of total IT experience. He has worked across different technologies and a wide range of data center products. He is an expert in Cisco Nexus 1000V and Cisco UCS products. He has more than 6 years of experience on VMware virtualization products.  
    Chetan Parik is a customer support engineer from the Server Virtualization team at the Cisco Technical Assistance Center in Bangalore, India. He has seven years of total experience. He has worked on a wide range of Cisco data center products such as Cisco UCS and Cisco Nexus 1000V. He also has five years of experience on VMware virtualization products.
    Remember to use the rating system to let Teclus and Chetan know if you have received an adequate response. 
    Because of the volume expected during this event, our experts might not be able to answer every question. Remember that you can continue the conversation in the Data Center community, under subcommunity Unified Computing, shortly after the event. This event lasts through May 9, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

    Hi Jackson,
    Yes its is possible.    Connect the storage array to the fabric interconnects using two 10GB links per storage processor.  Connect each SP to both fabric interconnects and configure the ports on the fabric interconnect as “Appliance” ports from UCSM
    For more information on how to connect Netapp storage using other protocols like iSCSI or FCOE  please check the url below.
    http://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-6100-series-fabric-interconnects/whitepaper_c11-702584.html
    Regards
    Teclus Dsouza

  • Ask the Expert: Cisco Unified Computing System Director

                With Andrew Nam
    Welcome to the Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about Cisco Unified Computing System (UCS) Director with Cisco expert Andrew Nam.
    Cisco UCS Director was designed to operationally integrate bare-metal and virtual data center infrastructure resources to address complex, time-consuming, manual, and compartmentalized management processes. These processes burden IT organizations, preventing them from achieving business agility and efficiency.  Cisco expert Andrew Nam will provide an update on installation, configuration, and troubleshooting VM provisioning process using Cisco UCS Director.
    Andrew Nam is a data center solution engineer in the DC Solution team in Sydney, Australia, responsible for orchestrating the end-to-end solution support of Cisco Data Centre solutions, including Cisco UCS, Cisco Nexus architecture, VBlock/FlexPod, VDI/VXI, and cloud solutions. His areas of expertise include routing and switching, load balancer, WAN optimization, VPN, and firewalls. Andrew has worked for Cisco for more than 13 years and has 15 years of experience in the networking industry. He graduated from New South Wales University in Australia with a mechanical/manufacturing engineering degree and holds R&S CCIE 9586, VMware VPC5, and Citrix CCA - Xendesktop5 certifications. 
    Remember to use the rating system to let Andrew know if you have received an adequate response. 
    Andrew might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation in Data Center community,  sub-community, Unified Computing discussion forum shortly after the event. This event lasts through January 17, 2014. Visit this forum often to view responses to your questions and the questions of other community members.

    Hi James
    This Ask the Expert session may not be the right place to show you all the essential steps for how the workflow can be related to task library to achieve your initial setup flow chart, and onboarding a new client.
    However, I can briefly walktthrough "Client blade Provisioning" task so it might give some idea and how you can go about.
    Assumption :  the infrastructure used in the following examples consists of:
    -  Vmware VCenter
    -  Cisco UCS
    -  NetApp ONTAP controlled storage
    To be able to provision Cisco UCS blade server in automated fashion, you need to create and define the below UCS entities beforehand.
    - Create UCS Organisation
    - Create UUID Pool
    - Create MAC Address Pool
    - Create WWNN Pool
    - Create WWPN Pool
    - Create vHBA Templates
    - Create vNIC Templates
    - Create UCS Policy vHBAs
    - Create UCS Policy vNICs
    - Create Storage Policy
    - Create Network Policy
    - Create SAN Boot Policy
    - Create LAN Boot Policy
    Once you create all the policy above, you are good to set up a workflow container for the client blade provisoining.
    1. Create UCS Service Profile
    - Add a ‘Create UCS Service Profile’ workflow task and select ‘Map to User Input’ for ‘Service Profile Name’. Select the ‘Service Profile Name’ dropdown as created when the workflow container was created.
    - ‘Create UCS Service Profile’ inputs. Ensure that Storage_Policy, Network_Policy, Boot_Policy_LAN and Boot_Policy_SAN entries are correct.
    - Once this is done , you can move to SAN zoning.
    2. Configure SAN Zoning
    - In this step, a new workflow task will be created in order to configure SAN zoning. Rather than use a specific user input for this task, output variables from the previous ‘Create UCS Service Profile’ workflow task will be used as input items for this task.
    - Open the workflow and search for the workflow task ‘configure san zoning’. Drag the storage workflow task into the work area and map the following user inputs.
    Create Flexible Volume
    - Create a ‘Create Flexible Volume’ workflow task in order to build a NetApp flexible volume and provision it for the required size.
    - Once again, reconfigure the workflow such that the success criteria from the ‘Configure SAN Zoning’ workflow task proceeds to ‘Create Flexible Volume’.
    Create LUN
    - Using the NetApp ONTAP ‘Create LUN’ workflow task, create a LUN located within the volume created during the previous step. In order to do this, map the Volume Name user input to the output from the previous ‘Create Flexible Volume’ workflow task.
    - Next, enter the LUN details, ensuring that the configured size is less than that of the volume created in the previous step.
    - As before, re-map the workflow designer flow so that the successful output of the Create Flexible Volume workflow task flows into this task.
    3. Create Initiator Group
    - Create a ‘Create Initiator Group’ workflow task in order to build a NetApp ONTAP Initiator Group. Map the ‘Filer Identity Name’ attribute to the OUTPUT_FILER_IDENTITY output variable as supplied by the ‘Create NetApp Flexible Volume’ workflow task as created earlier in this workflow.
    - Once again, modify the the workflow designer flow so that the successful output from ‘Create LUN’ flows into ‘Create Initiator Group’
    4. Add Initiator to Initiator Group
    - Create an ‘Add Initiator to Initiator Group’ workflow task and map the ‘Initiator Group Name’ entry to the OUTPUT_IGROUP_IDENTITY output variable from the ‘Create NetApp Initiator Group’ workflow task and map the ‘Initiator Name’ entry to the SP_VHBA1 output variable from the ‘Create UCS Service Profile’ workflow task created earlier in this flow.
    - Repeat this task for in order to add initiator name entry for SP_VHBA2. Once done, re-map the successful output from the two Create Initiator Group workflow tasks so that they flow into each other as follows:
    - Move onto the next step in order to map the created LUN to the initiator group.
    And the rest of steps are fairly similar to above. Create a Workflow and map the User Input Mappings".
    5. Map LUN to Initiator Group
    6. Modify UCS Boot Policy LUN ID
    7. Select UCS Server
    8. Associate UCS Service Profile
    9. Power On UCS Server
    10. Modify UCS Service Profile Boot Policy
    11. Add VLAN to Service Policy
    12. Disassociate UCS Service Profile
    13. Wait for Specified Duration
    14. Associate UCS Service Profile
    15. Power On UCS Server
    16. Register Host with VCenter
    regards
    Andrew

  • Ask the Expert: Cisco Unified Contact Center Express (UCCX) Version 10.0 - Upgrade, Migration, and New Features Overview

                With Abhiram Kramadhati 
    Welcome to the Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about the upgrade, migration methods, and new features of the latest released Version 10.0 of Cisco Unified Contact Center Express (UCCX) with Cisco expert Abhiram Kramadhati.
    Abhiram will address the following on the latest release of Cisco UCCX Version 10.0:
    Installation
    Upgrade from previous versions - both Linux and Windows   
    Migration from MCS to Cisco UCS environment - Different methods and best practices
    New features - Overview and limitations
    This discussion will center on install and upgrade best practices, changes in hardware support, and migration methods from MCS to Cisco UCS. He can also briefly discuss the new features introduced in 10.0. The discussion focuses the latest versions, but queries about general Cisco UCCX topics can be addressed too if time allows.
    Abhiram Kramadhati is an engineer with the Contact Center Backbone group. He has been working with Cisco UCCX since he joined Cisco. During two years at Cisco, he has built his expertise around Cisco UCCX telephony applications, Java Telephony API (JTAPI) integration, Cisco UCCX system behavior, LDAP components, and Cisco UCCX as IP interactive voice response in Unified Contact Center Enterprise (UCCE) environments. He also works on other technologies, including Unified Communications Manager and UCCE. He has been involved in many technical escalations in the Asia Pacific region. Abhiram also holds a CCIE in voice (40065).
    For more details about this topic, refer to the recently published Tech-Talk Video and Blog.
    Remember to use the rating system to let Abhiram know if you have received an adequate response. 
    Abhiram might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation in the Voice, Video, and Collaboration  community,  sub-community, Contact Center discussion forum shortly after the event. This event lasts through January 31, 2014. Visit this forum often to view responses to your questions and the questions of other community members.

    Hi Anurag,
    Thanks for your questions.
    1:Is there change in DB architecture as CUIC is the only option as compared to previous linux version UCCX ?
    I assume this is from the tables regarding historical data. The database schema essentially remains the same since UCCX 9.0 had CUIC too and we had a seperate DB Space for CUIC and we still continue with that. The traditional historical tables remain and the replication process remains the same too.
    2:Is there any version change for Linux OS used as VOS,
    The Linux version is Red Hat Linux 5. To be precise:
    [root@uccx10pub /]# cat etc/redhat-release
    Red Hat Enterprise Linux Server release 5.7 (Tikanga)
    3:Is there any API architecture change in UCCX 10 from previous releases ?
    I can answer this more of an overview. The only enhancement in the API side is the introduction of REST API step in the script editor. You can now make REST calls from the script and this ofcourse opens up a whole new world of possiblities.
    4:Since from UCCX 10 , we can only use either CAD or Finnesse at one  time, whats the impact of changing this after some time in production,  let say , i used CAD for 2 months and then i decided to move to Finesse,  whats the impact ? or is it a smooth change as switching CUIC and HRC  in previoius release ?
    For the scenario you mentioned, there is absolutely no problem. The point to note is that the Finesse services are activated/deactivated but the CAD desktop services are ALWAYS running. The only condition to keep in mind is that you can use ONLY ONE type of agent desktop at any time.  Also if Finesse is not used and CAD operations are used extensively, it is advisable to shutdown the Finesse service.
    5:Is 3rd Party UCS hardware supported by UCCX 10 instead of using Cisco manufactured UCS , can i use HP hardware for Virtualisation ?
    Yes, it can be used. This is something called as "Third party specs based specification". The most important things seen for compatibility are:
    Inter CPU Model
    It it is on thVMWare Hardware Compatibilty List
    You can get more information about this on the "Can I use this server?" section of UC Virtualized Hardware page:
    http://docwiki.cisco.com/wiki/UC_Virtualization_Supported_Hardware#.22Can_I_use_this_server.3F.22
    6:Is Host name change supported?
    Yes, the hostname change is supported. The prcocedure is documented in the UCCX 10.0 Administration Guide:
    http://www.cisco.com/en/US/docs/voice_ip_comm/cust_contact/contact_center/crs/express_10_0/configuration/guide/UCCX_BK_W1AF9DDD_00_uccx-admin-guide-10.0.pdf (Pg 168)
    Cheers,
    Abhiram Kramadhati

  • Ask the Expert: Cisco Nexus 2000, 5000, and 6000 Series Switches

    with Cisco Expert Vinayak Sudame
    Welcome to the Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions how to configure and troubleshoot the Cisco Nexus 2000, 5000 and 6000 Series Switches with Cisco subject matter expert Vinayak Sudame. You can ask any question on configuration, troubleshooting, features, design and Fiber Channel over Ethernet (FCoE).
    Vinayak Sudame is a Technical Lead in Data Center Switching Support Team within Cisco's Technical Services in RTP, North Carolina. His current responsibilities include but are not limited to Troubleshooting Technical support problems and Escalations in the areas of Nexus 5000, Nexus 2000, FCoE. Vinayak is also involved in developing technical content for Cisco Internal as well as external. eg, Nexus 5000 Troubleshooting Guide (CCO), Nexus 5000 portal (partners), etc. This involves cross team collaboration and working with multiple different teams within Cisco. Vinayak has also contributed to training account teams and partners in CAE (Customer Assurance Engineering) bootcamp dealing with Nexus 5000 technologies. In the past, Vinayak's responsibilities included supporting MDS platform (Fiber Channel Technologies) and work with EMC support on Escalated MDS cases. Vinayak was the Subject Matter Expert for Santap Technologies before moving to Nexus 5000 support. Vinayak holds a Masters in Electrical Engineering with Specialization in Networking from Wichita State University, Kansas. He also holds Cisco Certification CCIE (#20672) in Routing and Switching.
    Remember to use the rating system to let Vinayak know if you have received an adequate response.
    Vinayak might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation on the  Data Center sub-community, Other Data Center Topics discussion forum shortly after the event.
    This event last through Friday July 12, 2013. Visit the community often to view responses to youe questions of other community members.

    Hi Vinayak,
    Output of "show cfs internal ethernet-peer database"
    Switch 1
    ETH Fabric
    Switch WWN              logical-if_index
    20:00:54:7f:ee:b7:c2:80 [Local]
    20:00:54:7f:ee:b6:3f:80 16000005
    Total number of entries = 2
    Switch 2
    ETH Fabric
    Switch WWN              logical-if_index
    20:00:54:7f:ee:b6:3f:80 [Local]
    20:00:54:7f:ee:b7:c2:80 16000005
    Total number of entries = 2
    Output of "show system internal csm info trace"
    Switch 1 in which "show cfs peers" show proper output
    Mon Jul  1 05:46:19.145339  (CSM_T) csm_sp_buf_cmd_tbl_expand_range(8604): No range command in buf_cmd_tbl.
    Mon Jul  1 05:46:19.145280  (CSM_T) csm_set_sync_status(6257): Peer RT status PSSed
    Mon Jul  1 05:46:19.145188  (CSM_T) csm_sp_handle_local_verify_commit(4291):
    Mon Jul  1 05:46:19.145131  csm_continue_verify_ac[597]: peer is not reachable over CFS so continuing with local verify/commit
    Mon Jul  1 05:46:19.145071  csm_tl_lock(766): Peer information not found for IP address: '172.16.1.54'
    Mon Jul  1 05:46:19.145011  csm_tl_lock(737):
    Mon Jul  1 05:46:19.144955  (CSM_EV) csm_sp_build_tl_lock_req_n_send(941): sending lock-request for CONF_SYNC_TL_SESSION_TYPE_VERIFY subtype 0 to Peer ip = (172.16.1.54)
    Mon Jul  1 05:46:19.143819  (CSM_T) csm_copy_image_and_internal_versions(788): sw_img_ver: 5.2(1)N1(2a), int_rev: 1
    Mon Jul  1 05:46:19.143761  (CSM_T) csm_sp_get_peer_sync_rev(329): found the peer with address=172.16.1.54 and sync_rev=78
    Mon Jul  1 05:46:19.143699  (CSM_T) csm_sp_get_peer_sync_rev(315):
    Mon Jul  1 05:46:19.143641  (CSM_EV) csm_sp_build_tl_lock_req_n_send(838): Entered fn
    Mon Jul  1 05:46:19.143582  (CSM_T) csm_set_sync_status(6257): Peer RT status PSSed
    Switch 2 in which "show cfs peers" does not show proper output
    Mon Jul  1 06:13:11.885354  (CSM_ERR) csm_pss_cmd_tree_walk_cb(2057): Parent command not found for cmd switchport mode trunk, cmd pseq 77 seq 482
    Mon Jul  1 06:13:11.884992  (CSM_ERR) csm_pss_cmd_tree_walk_cb(2057): Parent command not found for cmd channel-group 51 mode active, cmd pseq 357 seq 369
    Mon Jul  1 06:13:11.884932  (CSM_ERR) csm_pss_cmd_tree_walk_cb(2057): Parent command not found for cmd switchport trunk allowed vlan 2, 11, cmd pseq 357 seq 368
    Mon Jul  1 06:13:11.884872  (CSM_ERR) csm_pss_cmd_tree_walk_cb(2057): Parent command not found for cmd switchport mode trunk, cmd pseq 357 seq 367
    Mon Jul  1 06:13:11.884811  (CSM_ERR) csm_pss_cmd_tree_walk_cb(2057): Parent command not found for cmd description process_vpc, cmd pseq 357 seq 366
    Mon Jul  1 06:13:11.884750  (CSM_ERR) csm_pss_cmd_tree_walk_cb(2057): Parent command not found for cmd channel-group 51 mode active, cmd pseq 352 seq 365
    Mon Jul  1 06:13:11.884690  (CSM_ERR) csm_pss_cmd_tree_walk_cb(2057): Parent command not found for cmd switchport trunk allowed vlan 2, 11, cmd pseq 352 seq 364
    Mon Jul  1 06:13:11.884630  (CSM_ERR) csm_pss_cmd_tree_walk_cb(2057): Parent command not found for cmd switchport mode trunk, cmd pseq 352 seq 363
    Mon Jul  1 06:13:11.884568  (CSM_ERR) csm_pss_cmd_tree_walk_cb(2057): Parent command not found for cmd description process_vpc, cmd pseq 352 seq 362
    Mon Jul  1 06:13:11.884207  (CSM_EV) csm_sp_acfg_gen_handler(3011):  Preparing config into /tmp/csm_sp_acfg_1733916569.txt
    Mon Jul  1 06:13:11.878695  csm_get_locked_ssn_ctxt[539]: Lock not yet taken.
    Mon Jul  1 06:13:11.878638  (CSM_EV) csm_sp_acfg_gen_handler(2937): Recieved sp acfg merge request for type: running cfg
    Mon Jul  1 06:12:29.527840  (CSM_T) csm_pss_del_seq_tbl(1989): Freeing seq tbl data
    Mon Jul  1 06:12:29.513255  (CSM_T) csm_sp_acfg_gen_handler(3106): Done acfg file write
    Mon Jul  1 06:12:29.513179  (CSM_EV) csm_sp_acfg_gen_handler(3011):  Preparing config into /tmp/csm_sp_acfg_1733911262.txt
    Mon Jul  1 06:12:29.508859  csm_get_locked_ssn_ctxt[539]: Lock not yet taken.
    Mon Jul  1 06:12:29.508803  (CSM_EV) csm_sp_acfg_gen_handler(2937): Recieved sp acfg merge request for type: running cfg
    Mon Jul  1 05:53:17.651236  Collecting peer info
    Mon Jul  1 05:53:17.651181  Failed to get the argumentvalue for 'ip-address'
    Mon Jul  1 05:40:59.262736  DB Unlocked Successfully
    Mon Jul  1 05:40:59.262654  Unlocking DB, Lock Owner Details:Client:1 ID:1
    Mon Jul  1 05:40:59.262570  (CSM_T) csm_sp_del_buf_cmd(1713): Deleting comand with Id = 1
    Mon Jul  1 05:40:59.262513  DB Lock Successful by Client:1 ID:1
    Mon Jul  1 05:40:59.262435  Recieved lock request by Client:1 ID:1
    Mon Jul  1 05:40:41.741224  ssnmgr_ssn_handle_create_get: Session FSM already present, ID:1
    Mon Jul  1 05:40:41.741167  ssnmgr_handle_mgmt_request: Create/Get request received for session[process_n5kprof]
    show cfs lock gives no output.
    Just to further clarify, we have 4 5548UP switches in the same management vlan. 2 switches are in one location lets say location A and they are CFS peers and are working fine.
    These two switches which are having problem are in location B. All the switches are in the same vlan. Essentially the all CFS multicast messages will be seen by all 5548 switches as they are in the same vlan. I am assuming that this might not create any problems as we specify the peers in the respective configurations. Or do we have to change the CFSoIPv4 multicast addresses in location B or may be configure a different region.
    Regards.

  • Ask the Expert: Cisco BYOD Wireless Solution: ISE and WLC Integration

    With Jacob Ideji, Richard Hamby  and Raphael Ohaemenyi   
    Welcome to the Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about  the new Identity Solutions Engine (ISE) and Wireless LAN Controller (WLC) hardware/software, integration, features, specifications, client details, or just questions about  Cisco's Bring-your-own device (BYOD) solution with cisco Experts Richard Hamby, Jacob Ideji, and Raphael Ohaemenyi. The interest in BYOD (Bring You Own Device) solutions in the enterprise has grown exponentially as guests and company users increasingly desire to use personal devices to access .  Cisco BYOD enhances user experience and productivity while providing security, ease-of-administration, and performance. The heart of the Cisco wireless BYOD solution is Identity Solutions Engine (ISE) utilizing the Cisco Unified Wireless portfolio.  Starting with ISE v1.1.1MR and WLC (Wireless LAN Controller) code v7.2.110.0 and higher, end-to-end wireless BYOD integration is reality. 
    Jacob Ideji is the technical team lead in the Cisco authentication, authorization and accounting (AAA) security team in Richardson, Texas. During his four years of experience at Cisco he has worked with Cisco VPN products, Cisco Network Admission Control (NAC) Appliance, Cisco Secure Access Control Server, and Dot1x technology as well as the current Cisco Identity Services Engine. He has a total of more than 12 years experience in the networking industry. Ideji holds CCNA, CCNP, CCSP, CCDA, CCDP, and CISM certifications from Cisco plus other industry certifications.
    Richard Hamby  works on the Cisco BYOD Plan, Design, Implement (PDI) Help Desk for Borderless Networks, where he is the subject matter expert on wireless, supporting partners in the deployment of Cisco Unified Wireless and Identity Services Engine solutions. Prior to his current position, Hamby was a customer support engineer with the Cisco Technical Assistance Center for 3 years on the authentication, authorization, accounting (AAA) and wireless technology teams. 
    Raphael Ohaemenyi  Raphael Ohaemenyi is a customer support engineer with the authentication, authorization and accounting (AAA) team in the Technical Assistance Center in Richardson, Texas, where he supports Cisco customers in identity management technologies. His areas of expertise include Cisco Access Control Server, Cisco Network Admission Control (NAC) Appliance, Cisco Identity Services Engine, and IEEE 802.1X technologies. He has been at Cisco for more than 2 years and has worked in the networking industry for 8 years. He holds CCNP, CCDP, and CCSP certification.
    Remember to use the rating system to let Jacob, Richard and Raphael know if you have received an adequate response.  
    Jacob, Richard and Raphael might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation on the wireless mobility sub community forum shortly after the event. This event lasts through Oct 5th, 2012. Visit this forum often to view responses to your questions and the questions of other community members.

    OOPS !!
    I will repost the whole messaqge with the correct external URL's:
    In  general, the Trustsec design and deployment guides address the specific  support for the various features of the 'whole' Cisco TS (and other  security) solution frameworks.  And then a drill-down (usually the  proper links are embedded) to the specifc feature, and then that feature  on a given device.  TS 2.1 defines the use of ISE or ACS5 as the policy  server, and confiugration examples for the platforms will include and  refer to them.
    TrustSec Home Page
    http://www.cisco.com/en/US/netsol/ns1051/index.html
    http://www.cisco.com/en/US/solutions/collateral/ns170/ns896/ns1051/product_bulletin_c25-712066.html
    http://www.cisco.com/en/US/prod/collateral/vpndevc/ps5712/ps11637/ps11195/at_a_glance_c45-654884.pdf
    I find this page very helpful as a top-level start to what features and capabilities exist per device:
    http://www.cisco.com/en/US/solutions/ns170/ns896/ns1051/trustsec_matrix.html
    The TS 2.1 Design Guides
    http://www.cisco.com/en/US/solutions/ns340/ns414/ns742/ns744/landing_DesignZone_TrustSec.html
    DesignZone has some updated docs as well
    http://www.cisco.com/en/US/netsol/ns982/networking_solutions_program_home.html#~bng
    As  the SGT functionality (at this point) is really more of a  router/LAN/client solution, the most detailed information will be in the  IOS TS guides like :
    http://www.cisco.com/en/US/docs/switches/datacenter/sw/6_x/nx-os/security/configuration/guide/b_Cisco_Nexus_7000_NX-OS_Security_Configuration_Guide__Release_6.x.html
    http://www.cisco.com/en/US/docs/ios-xml/ios/sec_usr_cts/configuration/xe-3s/asr1000/sec-usr-cts-xe-3s-asr1000-book.html
    http://www.cisco.com/en/US/docs/switches/lan/trustsec/configuration/guide/trustsec.html

  • Ask the Expert: Cisco TelePresence for the Enterprise

    Welcome to the Cisco® Support Community Ask the Expert conversation.  This is an opportunity to learn and ask questions about Cisco Telepresence® for the enterprise. 
    Cisco experts Jaret, Fernando, and Fred will be covering all Cisco TelePresence products.  Topics include Cisco TelePresence endpoints and TelePresence infrastructure such as the Cisco TelePresence Video Communication Server (VCS), Cisco Expressway Series, Cisco Unified Communication Manager (CallManager), Cisco TelePresence Servers (MSE 8710, on Virtual Machine, etc.), MCU (MSE 8510, etc.), Cisco TelePresence Management Suite (TMS), and all other Cisco TelePresence related devices.
    Jaret Osborne is an 8-year Cisco Advanced Services veteran.  In his Advanced Services tour, Jaret has covered all aspects of Cisco Unified Communications and TelePresence products, including both enterprise and service provider verticals. Most recently Jaret has been working with global service providers supporting their Cisco TelePresence as a Service offerings while also incubating new cloud services at Cisco.
    Fernando Rivas is a Cisco Advanced Services NCE, starting in the Cisco Technical Assistance Center (TAC), 2007, on the Collaboration Technology Team mastering the Cisco Unified Communication  technologies and specialized in call control CUCM,VCS) and  conferencing (MeetingPlace, Telepresence). In 2011, he joined Cisco Advanced Services as a member of the Cisco Collaboration team and participated in several Cisco TelePresence and video-related technologies deployments. Currently he is a member of the Video Cloud Technology Team, supporting video exchanges in several and architecting new private video cloud solutions for large enterprises. Fernando holds a routing and switching CCIE® certification (22975).
    Fred Mollenkopf  is a Cisco Advanced Services Network consulting engineer working at Cisco for the last 7 years. Fred has led some of the largest Cisco Unified Communication and Collaboration deployments done for Cisco customers and partners. Over 15 years’ experience in data networking with a specialization in Cisco Unified Communications in 2004. Currently he is a member of the SP Video Advanced Services Team, supporting SP video exchanges and the Cisco Telepresence solutions.  Fred maintains an active CCIE® in Voice (17521).
    Remember to use the rating system to let Jaret, Fernando, and Fred know if you have received an adequate response. 
    Because of the volume expected during this event, Jaret, Fred, and Fernando might not be able to answer every question. Remember that you can continue the conversation in the Collaboration, Voice and Video Community, under the sub-community TelePresence, shortly after the event. This event lasts through August 15, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

    Tenaro,
    Additionally here are the most common login issues.  Unfortunately this includes items related to Presence implementation but I commented where we did not use these in our lab setup for CUCM Phone Capabilities only.  
    Login Issues
    Problem:
    Jabber Unable to Sign-in Through MRA
    Solution
    This can be caused by a number of things, a few of which are outlined below.
     1.  Collaboration Edge SRV record not created and/or port 8443 unreachable
    For a jabber client to be able to login successfully using MRA, a specific collaboration edge SRV record must be created and accessible externally. When a jabber client is initially started it will make server DNS SRV queries:
    _cisco-uds : this SRV record is used to determine if a CUCM server is available.
    _cuplogin : this SRV record is used to determine if an IM&P server is available.
    _collab-edge : this SRV record is used to determine if MRA is available.
    If the jabber client is started and does not receive an SRV answer for _cisco-uds and _cuplogin, and does receive an answer for _collab-edge then it will use this answer to try to contact the Expressway-E listed in the SRV answer.
    The _collab-edge SRV record should point to the FQDN of the Expressway-E using port 8443. If the _collab-edge SRV is not created, or is not externally available,  or if it is available, but port 8443 is not reachable, then the jabber client will fail to login.
     2.  Unacceptable or No Available Certificate on VCS Expressway
    After the jabber client has received an answer for _collab-edge, it will then contact the expressway using TLS over port 8443 to try to retrieve the certificate from the expressway to setup TLS for communication between the jabber client and the expressway.
    If the Expressway does not have a valid signed certificate that contains either the FQDN or domain of the Expressway, then this will fail and the jabber client will fail to login.
    If this is occurring, the you should use the CSR tool on the Expressway, which will automatically include the FQDN of the expressway as a Subject Alternative Name.
    MRA requires secure communication between the Expressway-C and Expressway-E, and between the Expressway-E and external endpoints.
    Expressway-C Server Certificate Requirements:
    The Chat Node Aliases configured on the IM&P servers. This is required if you are doing XMPP federation.  The Expressway-C should automatically include these in the CSR provided that an IM&P server has already been discovered on the Expressway-C.
    The names in FQDN format of all Phone Security Profiles in CUCM configured for TLS and used on devices configured for MRA. This allows for secure communication between the CUCM and Expressway-C  for the devices using those Phone Security Profiles.
    Expressway-E Server Certificate Requirements:
    All domains configured for Unified Communications. This includes the domain of the Expressway-E and C, e-mail address domain configured for Jabber, and any presence domains.
    The Chat Node Aliases configured on the IM&P servers. This is required if you are doing XMPP federation. 
    The MRA Deployment guide describes this in greater detail on pages 17-18. (http://www.cisco.com/c/dam/en/us/td/docs/voice_ip_comm/expressway/config_guide/X8-1/Mobile-Remote-Ac...
    Note: In our lab for testing Phone Capabilities only, we did not include the Chat Node Aliases in the certificate as we were not using IM&P.
     3.  No UDS Servers Found in Edge Config
    After the Jabber client successfully establishes a secure connection with the Expressway-E, it will ask for its edge config. This edge config will contain the SRV records for _cuplogin and _cisco-uds. If these SRV records are not returned in the edge config, then the jabber client will not be able to proceed with trying to login.
    To fix this, make sure that _cisco-uds and _cuplogin SRV records are created internally and resolvable by the Expressway-C
    More information on the DNS SRV records can be found on page 10 of the MRA deployment guide for X8.1.1 (http://www.cisco.com/c/dam/en/us/td/docs/voice_ip_comm/expressway/config_guide/X8-1/Mobile-Remote-Access-via-Expressway-Deployment-Guide-X8-1-1.pdf)
    Note: In our lab for testing Phone Capabilities only, we did not include the DNS SRV for _cuplogin.
     4.  The Expressway-C logs will indicate the following error: XCP_JABBERD  Detail="Unable to connect to host '%IP%', port 7400:(111) Connection  refused"
    If Expressway-E NIC is incorrectly configured, this can cause the XCP server to not be updated. If the Expressway-E meets the following criteria, then you will likely have this issue:
    Using a single NIC
    Advanced Networking Option Key is installed
    Use Dual Network Interfaces option is set to “Yes”
    To correct this problem, change the “Use Dual Network Interfaces” option to “No”
    The reason this is a problem is because the Expressway-E will be listening for the XCP session on the wrong network interface, which will cause the connection to fail/timeout. The Expressway-E listens on TCP port 7400 for the XCP session. You can verify this by using the netstat command from the VCS as root.
    Note: We used a Dual Network Interface Expressway for testing but were not using XCP, so this was not applicable to us.
     5.  VCE-E Server hostname/domain name does not match what is configured in the _collab-edge SRV.
    If the Expressway-E Server hostname/domain name does not match what was received in the _collab-edge SRV answer, the jabber client will not be able to communicate to the Expressway-E. The Jabber client uses the xmppEdgeServer/Address element in the get_edge_config response to establish the XMPP connection to the Expressway-E.
    This is an example of what the xmppEdgeServer/Address would look like in the get_edge_config response from the Expressway-E to the Jabber client:
    <xmppEdgeServer>
    <server>
    <address>ott-vcse1.vcx.cisco.com</address>
    <tlsPort>5222</tlsPort>
    </server>
    </xmppEdgeServer>
    To avoid this, make sure that the _collab-edge SRV record matches the Expressway-E hostname/domain name. Enhancement CSCuo83458 has been filed for this. 
    Note: This was one of our issues when we first setup.  We adjusted our Expressway-E to insure the below:
    System > Administration > System Name this was the FQDN
    System > DNS > System Host Name was the host portion of the FQDN
    System > DNS > Domain Name was the domain portion of the FQDN
    System > Clustering > Cluster Name (FQDN for Provisioning) was the FQDN
     6. Unable to log into certain IM&P servers. VCS logs say "No realm found for host cups-example.domain.com, check connect auth configuration"
    From the Expressway-E, go to Configuration -> Unified Communications -> IM&P Servers. Open each server and click "Save" again. Not sure exactly why this happens.
    Note:  This was N/A to our test and can be ignored with Phone Capabilities only.
    Thanks
    Fred

  • Ask the Expert: Cisco Hosted Collaboration Solution

    With Chris Ward
    Welcome to the Cisco Support Community Ask the Expert conversation.This is an opportunity to learn about Cisco's new Hosted Collaboration Solution architecture and deployment with Cisco expert Chris Ward. Chris is a technical marketing engineer working on the Cisco Hosted Collaboration Solution. He previously held an escalation position in the Cisco Technical Assistance Center for the Cisco Unified Communications Manager team, where he worked for more than five years. Ward holds bachelor and master of science degrees in information technology from the Rochester Institute of Technology and also holds CCIE Voice certification.
    Remember to use the rating system to let Chris know if you have received an adequate response. 
    Chris might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation on the Service Provider sub-community discussion forum shortly after the event. This event lasts through April 20 , 2012. Visit this forum often to view responses to your questions and the questions of other community members.

    Hi Tenaro,
    Thank you for your question.
    At current, we do not setup CUCM in a multi-tenant configuration. Each HCS end-customer gets their own unique CUCM cluster, the same goes for Unity Connection and Unified Presence.
    There are a few pieces of software that are unique to HCS
    1) HCM - F - This component is used to automate the upgrades of the UC applications, produce bundle-based billing reports from the configuration domain, and also automatically provision/configure the Service Assurance architecture so as you deploy HCS to end customers, the monitoring of those configurations is automatically done for you.
    2) Prime Central for HCS Assurance - This component is responsible for provides lots of functionality in regards to monitoring the HCS solution. It aggregates data from CUOM, CUSM, DCNM, and vCenter and can display all the events/errors/alarms that those components are reporting. It also has the ability to normalize these errors and forward them to an exisitng alarm management or ticketing system via SNMP traps. It also includes a reatures like fault correlation (root cause analysis) and service impact analysis which allows you to see what services are affected based on the error information that is being reported.
    3) This last item is not really a piece of software, but more an advantage over using UC on UCS as opposed to HCS. Within HCS we allow the over subscription of your UCS resources for some of the smaller OVAs where in UC on UCS you would be required to map a vCPU to an entire core. This allows for much greater denisty. Also, the HCS licensing scheme allows for the SP to pool licenses and transfer between the customers as needed where in UC on UCS, these licenses are bound to customers, once purchased.
    To answer your last question, we sell HCS to service providers and partners. Partners may need to have customers bring their own PSTN connectivity or partner with an SP to provide PSTN access, but either way, partners are just as capable of providing this service.
    Hope that helps. Thanks again Tenaro!

  • Ask the Expert:Cisco Web Security

    With Ryan Wager
    Welcome to the Cisco Support Community Ask the Expert conversation. This is an opportunity to learn about design, configuration and troubleshooting of the Cisco Web Security Solutions including Cisco Ironport WSA and Cisco ScanSafe with Cisco experts Kiran Sirupa and Ryan Wager. Kiran Sirupa is a technical marketing engineer in the product marketing team for the Cisco IronPort Web Security Appliance product line. He also works on documentation, partner ,and system engineering training. Kiran has been working in the Cisco Security Technologies group for more than six years. Ryan Wager is a technical marketing engineer at Cisco in the product management team for the ScanSafe Web Security platform. He is heavily involved with the product's integration with the Cisco Integrated Services Router Generation 2 platform, along with documentation, training, and testing of all new products and features. Before joining the product management team, Wagner spent two years as an implementation engineer helping ScanSafe's largest customers implement the platform into their networks.
    Remember to use the rating system to let Kiran and Ryan know if you have received an adequate response.  
    They might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation on the Security sub-community, discussion forum shortly after the event. This event lasts through October 7, 2011.. Visit this forum often to view responses to your questions and the questions of other community members.

    Yes, the IronPort WSA will support all the security functions including Anti-Virus, Anti-Malware, Anti-Spyware, Web Reputation when working in conjunction with an existing proxy.
    There are two conditions:
    1. WSA acts as an upstream proxy - In this case, the authentication will be handled by your existing proxy, but the WSA is the first layer of defense. The WSA will perform a lookup in its web reputation database based on the destination. Also, The WSA can scan the http response with Anti-Virus, Anti-SpyWare and Anti-Malware software. However, since the WSA doesn't have user authentication information, you can only apply global controls for Acceptable Use.
    2. WSA has to go through an existing upstream proxy - In this case, the WSA has all the security functionality. In addition, it also handles the authentication. Hence, you can apply role based controls.
    You may refer to the following links for more information:
    WSA Product Literature: http://www.cisco.com/en/US/products/ps10164/prod_literature.html
    Cisco Security Reports: http://www.cisco.com/en/US/prod/vpndevc/annual_security_report.html
    Cisco Security Intelligence Operations: http://tools.cisco.com/security/center/home.x

  • Ask the Expert: Cisco Prime Infrastructure - Implementation and Deployment

    Welcome to the Cisco Support Community Ask the Expert conversation.
    This Ask The expert Session will cover questions spanning Cisco Prime Infrastructure on Implementation and Deployment on Wired and Wireless. This will be more specific to Customer’s and Partners questions product covering PI on configuration, Features and Menu, Network Monitoring, Maps, Implementation, High Availability and Maintenance and t/s parts.
    Monday, February 2nd, 2015 to Friday, February 13th, 2015
    Dhiresh Yadav is a customer support engineer in High-Touch Technical Services (HTTS)  handling supporting Wireless and Network Management based Cisco products and is based in Bangalore. His areas of expertise include Cisco Prime Infrastructure and Cisco Wireless products. He has over 7 years of industry experience working with large enterprise and service provider networks. He also holds CCNP (RS) and CCIE (DC) certifications.
    Afroz Ahmad is a customer support engineer in High-Touch Technical Services (HTTS)  handling supporting Wireless and Network Management based Cisco products and is based in Bangalore. His areas of expertise include Cisco NMS products like Prime Infrastructure, LMS, IP SLA and SNMP etc. He has over 7 years of industry experience working with large enterprise and service provider networks. He also holds CCNP (RS),CCIE (DC), and SCJP (Sun Certified Java Professional )
    Vinod Kumar Arya is a customer support engineer in High-Touch Technical Services (HTTS)  handling supporting Wireless and Network Management based Cisco products and is based in Bangalore. His areas of expertise include Cisco NMS products like Prime Infrastructure, LMS, IP SLA and SNMP etc. He has over 8 years of industry experience working with large enterprise and service provider networks. He also holds VCP 5 and RHCE certifications.
    ** Remember to use the rating system to let the experts know you have received an adequate response.**
    Because of the volume expected during this event, the experts might not be able to answer every question. Remember that you can continue the conversation in the Network Infrastructure community, > Network Management, shortly after the event. This event lasts through February 13th 2015. Visit this forum often to view responses to your questions and those of other Cisco Support Community members.

    Hello Wilson,
    Thanks for joining us.
    1841 should just work fine for net flow . Hope you have a valid "PI Assurance license" installed on the server.
    "PI Assurance license" is required for "net-flow"  feature
    Devices supporting Netflow in PI ::
    1400, 1600, 1700 & 1800
    2500, 2600 & 2800
    3600, 3700, 3750 & 3800
    4500 & 4700
    AS5300 & 5800
    7200, 7300, 7400 & 7500
    Catalyst 4500 ASCI
    Catalyst 5000, 6500, & 7600 ASCI
    ESR 10000 ASCI
    GSR 12000 ASCI
    Cisco IOS Software Release Version
    Supported Cisco Hardware Platforms
    11.1CA, 11.1CC
    Cisco 7200 and 7500 series, RSP 7200 series
    12.0
    Cisco 1720, 2600, 3600, 4500, 4700, AS5800 
    RSP 7000 and 7200 series
    uBR 7200 and 7500 series
    RSM series
    12.0T, 12.0S
    Cisco 1720, 2600, 3600, 4500, 4700, AS5800 
    RSP 7000 and 7200 series
    uBR 7200 and 7500 series
    RSM series, MGX8800RPM series, and BPx8600 series
    12.0(3)T, 12.0(3)S
    Cisco 1720, 2600, 3600, 4500, 4700, AS5300, AS5800
    RSP 7000 and 7200 series
    uBR 7200 and 7500 series
    RSM series, MGX8800RPM series, and BPx8650 series
    12.0(4)T
    Cisco 1400, 1600, 1720, 2500, 2600, 3600, 4500,
    4700, AS5300, AS5800
    RSP 7000 and 7200 series
    uBR 7200 and 7500 series
    RSM series, MGX8800RPM series, and BPx8650 series
    12.0(4)XE
    Cisco 7100 series
    12.0(6)S
    Cisco 12000 series
    NetFlow is also supported by these devices Cisco 800, 1700, 1800, 2800, 3800, 6500, 7300, 7600, 10000, CRS-1 and these Catalyst series switches: 45xx, 55xx, 6xxx.
    NetFlow export is also supported on other Cisco switches when using a NetFlow Feature Card (NFFC) or NFFC II and the Route Switch Module (RSM), or Route Switch Feature Card (RSFC). However, check whether version 5 is supported, as most switches export version 7 by default.
    You can check the below steps to diagnose the issue::
     To verify that NetFlow is exported from a device to PI, follow the steps below:
    1)    Browse to Administration > Data Sources page. Check the value in column ‘Last Active Time’  for the ‘Device Data Sources’ table. If the table is empty or  the value does not represent recent time, then
    it is possible that the device is not exporting NetFlow or PI Assurance license is not applied / expired.
    2)    Login to PI console ( via SSH) as root user and run the command:
                    netstat –an | grep 9991 – Output of this should be like :  udp        0      0 :::9991         :::*
                    Check the firewall settings on PI server using the command: firewall -L
    1)    Check the configuration on an IOS / IOS –XE device. Run the commands
    a)    sh running-config | inc destination
    1)    This should list the IP address of the PI SERVER ( along with other outputs if any)
    b)    sh running-config | inc 9991
    1)    This should list at least one entry.
    c)    If the above are fine, then verify that the flow monitor, flow exporter and the flow records are correctly configured on the device.
    Refer to the URLs below to configure NetFlow export.
    http://preview.cisco.com/en/US/docs/net_mgmt/prime/infrastructure/2.0/user/guide/setup_monitor.html#wp1056427
    Thanks-
    Afroz
    ***Ratings Encourages Contributors ****

  • ASK THE EXPERTS: Cisco's Hosted Collaboration Solution

    With Chris Ward
    Welcome to the Cisco Support Community Ask the Expert conversation.This is an opportunity to learn about Cisco's new Hosted Collaboration Solution architecture and deployment with Cisco expert Chris Ward. Chris is a technical marketing engineer working on the Cisco Hosted Collaboration Solution. He previously held an escalation position in the Cisco Technical Assistance Center for the Cisco Unified Communications Manager team, where he worked for more than five years. Ward holds bachelor and master of science degrees in information technology from the Rochester Institute of Technology and also holds CCIE Voice certification.
    Remember to use the rating system to let Chris know if you have received an adequate response.  
    Chris might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation on the Other Service Provider Subjects discussion forum shortly after the event. This event lasts through July 29, 2011. Visit this forum often to view responses to your questions and the questions of other community members.

    Hi J,
    The process of creating a new customer is not yet fully automated, but we are working on vCenter integration that may eventually automate this process. With HCS, you would build a "golden template" of the UC apps that your customers would be consuming.
    The golden template is essentially an image of the UC App (UCM Pub, UCM Sub, UCxN, and CUP) that has parameters and configurations that you think every customer will be using. There are some caveats to what you configure since the provisioning tool, Cisco Unified Communications Domain Manager (UCDM), will be provisioning the system for you after you create the customer instances.
    Once you have your golden templates, you are ready to start rolling out customers. You would clone the golden templates to create your new customer instance. Then you run what are called the "new identity" scripts on the cloned VMs. This new Identity script is built into the UC application (From 8.0 and later). It essentially involves you using the Answer File Generator on cisco.com to create an answer file for the application of interest and then you mount this answer file via a floppy image to your newly cloned VM. Once the floppy is mounted, you can go ahead and run the new identity script "utils import config" from the CLI of the UC app. It will rename, re-IP, change DNS servers, and lots of other platform information about the system that you can configure. Finally, it will reboot the system. Some of this process can also be automated using VMware's vMA toolset using scripts that the HCS team can provide.
    Once the new identity script has been run, you have a new install for your new customer. Then you would input the new address information into UCDM and begin the bulk provisioning of the system. The UCDM would be bulk creating users, phones, VM accounts, partitions, CSS's, and just about everything else for the UC environment.
    Once again, stay tuned for some future automation enhancements in this area, but at current (HCS 8.0.2 and soon to be 8.6.1) this is the method for provisioning a new customer from scratch in VMware.

  • Ask the Expert:Cisco Prime Network Registrar

    With Pete Newcomb & Jim Brown 
    Welcome to the Cisco Support Community Ask the Expert conversation. Learn from experts Peter Newcomb and Jim Brown about  Cisco Prime Network Registrar, Cisco's industry leading solution for integrated DNS, DHCP and  IP address management (IPAM) services  for both IPv4 and IPv6. 
    Pete Newcomb is a technical marketing engineer in Cisco's Network Management and Technology Group and has over 30 years of experience in the voice and data communications industry, including sales support and product engineering support with several companies. His design and development background includes wireless services, switching, routing, TCP/IP, Frame Relay, X.25, telephony services, risk management, and network security. 
    Jim Brown is a customer support  engineer in Cisco's Network Management and Technology Group. He has over 35 years of experience in development engineering and customer service, real-time and fault tolerant operating systems, and network management for the telecommunications and software industries. For the last 14 years he has been with the Network Registrar Development Team, interfacing with Customer Service and directly with customers in problem solving.
    Remember to use the rating system to let Pete and Jim know if you have received an adequate response.  
    Pete and Jim might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation on the Network Infrastructure sub-community   forum shortly after the event. This event lasts through January 18, 2013. Visit this forum often to view responses to your questions and the questions of other community members.

    Hi Jorge,
       Absolutely, Prime CNR supports IPv6 since CNR 6.x versions...
       For IPv6 configuration instructions on latest versions of CPNR you should start here;
          http://www.cisco.com/en/US/partner/docs/net_mgmt/prime/network_registrar/8.1/user/guide/UG25_IP6.html
                                                        Best Regards
                                                        Jim Brown

  • Boot from san with local disk

    I have some B200M3's with local disk.  I would like to configure them to boot from san.  I've setup a service profile template with a boot policy to boot from CD first and then the SAN.  I have a local disk configuration policy to mirror the local disks.   I've zoned the machines so that it presently only sees one path to the storage because I'm installing windows and I don't want it to see the disks funky because of multiple paths to the same disk.  When I boot the machine it sees the disk.  I boot to the Windows 2012R2 iso and load the drivers for the cisco mlom and then the single lun will appear.  The local disk will also appear.  It can't install Windows 2012R2 on the SAN disk only the local disk.  It sees the local disk as disk 0 and the san disk as disk 3.  I don't know how to get the machine to see the san disk as disk 0.  I have the lun (which resides on an vnx5600) as lun 0.  The boot policy is configured to have the san lun as lun 0.  It even appears while booting the san lun appears as lun 0.  The error I'm getting from the windows installer is:  We couldn't install Windows in the location you chose.  Please check your media drive.  Here's more info about what happened: 0x80300001.  Any suggestions to get this to boot from SAN.

    Hi
    during the boot up process, do you see the wwpn of the target showing that the VIC can talk to the storage?
    Reboot the server in question, when you see the option to get into bios press F2, ssh to the primary fabrics a run the following commands
    connect adapter (x/x/x). <--- (chassis #/slot #/adapter#)
    connect
    attach-fls
    lunlist 
    (provide output of last command)
    lunmap 
    (provide output of last command)

  • Ask the Expert: Cisco's 802.11ac Solutions - Deployment, Design, and Interop

    Ask your Questions on Cisco’s 802.11ac Solutions - Deployment, Design, and Interop with Cisco Experts: Richard Hamby and Shankar Ramanathan.
    Monday, March 30th, 2015 to Friday, April 10th, 2015
     Richard Hamby is a senior technical support engineer and Team Lead of the Cisco Technical Assistance Center in Richardson, Texas.  He is an expert in Indoor and Outdoor wireless for the full line of Cisco Unified and Converged Access Wireless products, as well as TAC Engineering Engagement Engineer liaison to project engineering teams for new Cisco wireless products.  Prior to his current role, Richard was a customer support engineer with the AAA Security TAC team supporting Cisco identity management solutions and been with Cisco since 2009.
    Shankar Ramanathan is a Customer Support Engineer at the Cisco Technical Center. He is a Technical Content Engineer and Subject Matter Expert for Cisco Enterprise Unified and Converged Access wireless mobility solution including Wireless LAN Controller  2500/5500/WISM2/7500/8500, Converged access 5760/3650/3850 switches,  Access Points Lightweight and Autonomous, VoWLAN (792x/9971) , Cisco Prime Infrastructure SNMP management, Cisco Mobility Services Engine(MSE/ CMX). Prior to joining Cisco in  November 2011, he worked as a wireless network engineer at Elan Technologies, responsible for RF wireless network planning, simulation, propagation path analysis, and optimization of Wi-Fi 802.11 mesh and WiMax (802.16 d/e) networks for various system  integration and automation projects. Shankar holds a master of science degree in electrical engineering specializing in communications and signal process from the State University of New York, Buffalo. Shankar has a CCIE in Wireless(#40548) and CCNA  certified (number 410004168640IMZF) and has over six years of industry experience.
    Find other  https://supportforums.cisco.com/expert-corner/events.
    **Ratings Encourage Participation! **
    Please be sure to rate the Answers to Questions

    A common question we are asked is 'why is my device not achieving 11ac data rates?'
    One of the most common answers relates to client compatibility/capability. To get the highest possible data rates of 11ac (assuming proper distance and RF health), the AP and the client device must both be capable supporting the requirements - 5GHZ, 80MHz Channel, short guard interval, 3 spatial streams. Each spatial stream has a max of 433.3Mb/s (at 80MHz, short GI).
    The majority of 11ac-capable wireless cards on the market do not support 3 spatial streams. Most adapters in wireless-capable devices are 1SS or 2SS.  For example, the Intel 7260 11ac adapter used in many devices is a 2SS adapter - therefore it's max possible data rate is 866.7.  Another common adapter in use is the 11ac Broadcom 3SS that Apple uses in the newer Macbooks.  These devices can achieve the 1.3GBs PHY data rate.
    This guidance is the same for 11n adapters as well.  To achieve max rate, your 11n AP and adapter must both support 40MHz channels, 3SS, short GI.
    Note: The 11n and 11ac standards both define support for 4SS.  4SS-capable devices are rare, so 3SS is essentially our reality.
    One of the most useful references for questions related to this topic is the AP Data Sheet for each AP.  Here's the AP3700 for example:
    http://www.cisco.com/c/en/us/products/collateral/wireless/3700-series-access-point/data_sheet_c78-729421.html
    Table 1 lists the expected data rate per MCS Index value by #SS at each channel width and GI. Indexes 0-7 are the same for 11n and 11ac (11n limited to 40MHz channels of course).  And MCS 8 & 9 are 11ac-only 256-QAM modulations. 

  • Ask the Expert : Initial Set Up and LAN Connectivity for Cisco UCS Servers

    Welcome to the Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about related to the initial setup of UCS C & B Series which include LAN connectivity from the UCS perspective with Cisco subject matter expert Kenny Perez.
    In particularly, Kenny will cover topics such as: ESXi/Windows  installations, RAID configurations (best practices for good performance and configuration), VLAN/Jumbo Frames configuration for B series and C series servers, Pools/Policies/Upgrades/Templates/Troubleshooting Tips for blade and rack servers, Fabric Interconnects configuration, general compatibility of Hardware/Software/drivers amongst other topics
    Kenny Perez is a technical leader in Cisco Technical Assistance Center, where he works in Server Virtualization support team. His main job consists of supporting customers to implement and manage Cisco UCS B series and C series. He has background in computing, networking, and Vmware ESXi and has 3+ years of experience support UCS servers and is VCP certified.
    Remember to use the rating system to let Kenny know if he has given you an adequate response. 
    This event lasts through October 10th, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

    Hi,
    Actually  we have UCS 6248 fabric interconnect - first twelve ports are enabled  and same in Cisco UCS Manager.
    But when more port will be active by expansion module  then UCSM can manage that too or need any other licence  for UCSM too?

Maybe you are looking for

  • Using wifi on windows 8.1 pro

    I recently installed windows 8.1 pro on my macbook air 11" mid 2013 but the problem is i can't seem to use the built-in wifi of my mac when i switch to using windows 8.1 pro?what should i do?thanks

  • My mac mini & samsung monitor 172V don't work together

    I bought a mac-mini and connected it to my samsung monitor 172V. On screen the words " video mode not supported" appears. What does it mean? What can I do to make it work?

  • Can't open icloud

    My Safari opens to apple.com.  It goes to apple.com even though I type icloud.com.  On some days this happens repeatedly but on other days it goes directly to icloud.

  • No cursor at wakeup

    After my iMac G5 has been asleep for several hours or overnight, I do not get a cursor when I touch a key or click the mouse. In order to use my computer again, I have to turn it off with the power button and then turn it on again.

  • Date and Days for all year come in column

    Dear all I have 2 Column 1 is Date and 2nd is Day And i have one Button i need when i enter button then its show all year date in date column and day in day column for example Date---------Day+ *1-jan-2009-Thursday* *2-jan-2009-Friday* *3-jan-2009-Sa