Automatic Pause (through program) and Manual Resume through front panel Button

Hi, I am trying to implement a system which measures voltage and current for a varying source voltage at varying temperature. The program acquires 5 pairs of voltage and current data. The issue here is that the source voltage is varied by manually changing the value of the variable resistor. What I would like to do is somehow pause the program automatically once the loop (for acquiring 5 V and I data pairs) has completed. Then, after the user manually changes the value of the variable resistor (and enters the new value through a front panel indicator), the user should be able to resume the program through a front panel button like in this example: https://decibel.ni.com/content/docs/DOC-10792
Is it possible to implement this in LabView?
In summary: I would like to implement a system in which the program would pause automatically after a condition has been fulfilled, and can be resumed through a front panel button.
Thank you in advance for any help and suggestions. I hope I made my query clear. I'm not sure whether attaching the program would help but I included it just in case
Solved!
Go to Solution.
Attachments:
Resistivity Measurement.vi ‏132 KB

Hi all! I've overhauled my program after learning how to create state machines in LabVIEW. I think I've managed to make it able to pause program execution by staying in the Initialize state if Pause After Measurement is set to True, only resuming measurement once the user has pressed the front panel button to Acquire Data. Attached is the code for the program.
Thanks to you all for leading me to the right direction (I hope)  
I have other questions though for some other functions I want to implement in the program (which are not very relevant to the original topic title). Would it be better to start a new topic or continue the discussion here?
Attachments:
Resistivity Measurement v2.vi ‏159 KB

Similar Messages

  • Differences between Automatic Receipts Creation Program and Master Program

    This is something I observed today - I'm hoping someone can explain it to me.
    If I go through the Receipt Batches form and create a new batch for Automatic Receipts, this calls the Automatic Receipts Creation Program and my batch gets created successfully.
    If I launch the concurrent request Automatic Receipts Master Program, no receipts are created. But there are invoices in the system eligible for receipting.
    I'm trying to understand what the Automatic Receipts Master Program does differently? What does it do in general?

    This is something I observed today - I'm hoping someone can explain it to me.
    If I go through the Receipt Batches form and create a new batch for Automatic Receipts, this calls the Automatic Receipts Creation Program and my batch gets created successfully.
    If I launch the concurrent request Automatic Receipts Master Program, no receipts are created. But there are invoices in the system eligible for receipting.
    I'm trying to understand what the Automatic Receipts Master Program does differently? What does it do in general?

  • Enabling / Disabling graphs and opening a new Front Panel Window

    Hi,
      I have a simple application of showing 12 analog signals on 12 different graphs placed vertically in aligned position. I have to develop a user interface so that if user wants to display signal no. 1, 4 and 6 out of total 12 signals, he should make selection using check boxes and click a re-draw button. It should result in opening a separate window with these three signals displayed as separate graphs aligned vertically and adjusted to fit window size. Similarly later user can change his selection of displaying signals (from same acquired data) say 1, 3, 5, 6, 8, 9, 11 & 12 and click Redraw button. It should result in opening a new Window showing all these signals as separate graphs which are aligned vertically and resized to fit the window. Now I have two major issues in this context.
    1) I have been searching LabView help to locate a way to open a new window for this purpose but I failed to locate any way for it. As per my limited knowledge, it seems that we cannot have multiple "Front Panel" windows in Labview.
    2) For the graph I could not locate a control to enable/disable a graph so that it appears or vanishes. Is there any way to achieve it?
    I shall appreciate your valuable advice. I shifted from "Lab View Signal Express"  to "Lab View" in order to achieve this user interface design but I am still not successful in finding a good solution for this application.
    Regards
    Mnuet

    Hi Mnuet,
    You can do what was said above. Here is a KB on dynamically loading VIs. It looks something like this.
    Dynamically loaded VIs are loaded at the point in code while running, as opposed to being loaded when the parent VI is loaded into memory like normal subVIs. You can make a reference to them and then control the front panel appearance, their run status, etc with property nodes and invoke nodes.
    Jeff | LabVIEW Software Engineer

  • How to change the font and type in the front panel

    Can you tell me how to change the font and type in the front panel if i want to make it looks more beautiful.
    1110340040

    Hi there,
    You can change the font size and type as shown below:
    - Ee Lim -
    See that button on the left side of this post...
    If you feel my post is helpful, all you need is just (at most) 2 seconds to click that button, to show your appreciation. Thank you~~

  • Is it possible to change the font style and size of the front panel title?

    Can you change the style and size of the Front Panel Window title?  I seem to have no luck.  I seem to be stuck with only 1 font/style.  I would like to use a superscript for 1 of the letters in the title.  Is this possible?  If it isn't this would be a nice feature to have in the future.  I am using LabVIEW 8.5.1.

    Things like the window title font is a function of Windows - not LV. You can change it globally, but not on a window by window basis.
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • How can I stop and restart a .vi with a single front panel button?

    Hey guys, a newbie here.
    I have a .vi with a stacked sequence. The first few frames are hardware initialization and settings (LIN master node) and the data the hardware should transmit (frame response table). In the next frame there's a loop in which the hardware sends and recieves data (LIN monitor). If I want to change the initialization, settings or data values, I have to stop the .vi and restart it. I was wondering if there is a simple way of doing this with a single click (a button on the front panel).
    An alternative would be to put another loop outiside the whole stacked sequence and then run it a single time with a push of a button (the inner loop should let the outer one restart), is that possible?
    I hope I made any sense. Thanks for any suggestions.
    Tomaz
    Solved!
    Go to Solution.

    Ideally, redoing the code with a state machine would be the best way to go, if only so that you can add this powerful tool to your toolbox. That being said, wrapping your existing code in a while loop, with its own stop button to stop the program, will work if executing the entire sequence is ok. Where you might run into problems with this is if there is a step in the sequence that shouldn't be executed again, then it would require wrapping that sequence frame's code in a case statement that executes only the first time through. If you have the time, learning how to use a state machine would be a real benefit, really taking your LabVIEW knowledge to the next step, if you pardon the pun.
    Putnam
    Certified LabVIEW Developer
    Senior Test Engineer
    Currently using LV 6.1-LabVIEW 2012, RT8.5
    LabVIEW Champion

  • Open and close a vi front panel dynamicall​y

    I created a main vi panel that display all the signal names.  I like the main vi to open a new plot screen when I double click on the signal name.  I was able to do that using invoke node. But I when I close the plot screen by clicking on the Window "Close" button, the main vi was not able to open a new one again.  So I disabled the Window "Close" button and only use the "Stop" button coded in while loop in the blockdigram of the plot screen.  It worked, but the plot screen is still open and changed to editing mode.  Is there an easy way to close the plot screen by only one click.  Another question is that how does the main vi can open multiple plot screens.  Thanks for your advice.

    I think I know what happens:
    If you close the front panel of a sub-vi, the code is still running, so the VI doesn't terminate and somehow you can't address it (it don't know how you communicate with your sub-vi).
    So in your sub-vi you should monitor the panel-close event, and finish the code of the VI and finish the VI
    Ton
    Free Code Capture Tool! Version 2.1.3 with comments, web-upload, back-save and snippets!
    Nederlandse LabVIEW user groep www.lvug.nl
    My LabVIEW Ideas
    LabVIEW, programming like it should be!

  • Is there a way to use the built-in Datalogging and programmatically log the front panel while the vi is running?

    I would like to use the built-in Data Logging feature. There is the "Log at Completion" option, but is there a way to programmatically make a new log record while running? I looked around in VI server and couldn't find any methods that would do that. Currently, I am grabbing all of the front panel control references using VI Server and if there are any changes, the changed values are written to a log file along with a date/time stamp. I'm mostly dealing with buttons, which simply change from 0 to 1 or 1 to 0, so it's not too hard to visualize what was pressed. It works okay for reconstructing what happened, but it would be much nicer to use the built-in fe
    ature because you can "replay" directly onto the front panel and actually see what the changes were. However, without being able to programmatically make a new log, it won't work for me.

    Jake,
    There are several options here.
    I would suggest using your own code for datalogging. The datalogging you are referring to is primarily for debug, and one shot datalogs of front panel indicators (and controls?), not including graphs, etc.
    If you go to the file functions, you will see a menu for datalogging. These functions will allow you to save your data, as you need it, simply, and in a compact format.
    I recommend opening the datalog file, doing all your file operations, and closing the file before the program is complete. There are several examples of this in the examples database.
    Good luck

  • Auto save and auto recover of front panel controls/indicators values

    i just want that when i exit from the VI's front panel all controls and indicators current values get saved automatically and when i get back into this vi,those values get recovered automatically.
    Like if i incremented numeric control value from 1 to 5 , when i exit from the vi the value 5 get saved automatically and when i get back into the vi ,it shows the recovered value 5 to me automatically.
    best regards

    I'm Back
    I was mistaken when I said the you could select to save either the controls or indicators or both in the Open G Vi's, They are hard wired for both. I made minor changes to these VI's for my app.,  because I only needed the controls to be saved. The example I am providing uses the Modified VI's, but I've also included the originals.
    Modified
    Read Panel from INI.vi
    Write Panel to INI.vi
    Originals
    Read Panel from INI.vi
    Read Panel from INI__ogtk.vi
    The ability to select either or both could easily be implimented into these Vi's using a case selector and an enum wired as an input
    Controls only
    Indicators Only
    Both
    Incase you don't have the OpenG toolkit I've provided the necessary files for this example to function
    Extract the zip file to your User.lib directory then open Usage.vi
    Hope this helps you
    Georges Janveau
    Attachments:
    Config File Usage.zip ‏861 KB

  • How do I center and/or maximize the front panel on every event?

    Hi,
    So basically I have a little issue with trying to maximize and then scale back a VI's front panel every time a user selects a different option from a ring control.
    So far i've been using the LVWINUTIL.LLB and the provided window size vi to set the size I want on ring selection change which works fine, but as far as centering the VI goes, the method I'm calling only works the first time. After it maximizes and I select a different option on my ring control which is linked to a case within a while loop it simply resizes to the size i set which is correct but when I got back to the ring case which is supposed to maximize the front panel again, it doesn't do it. Centralizing the FP also only works once.
    I'm  using FP.Run-Time Position.Centered to try and center the VI....only works once. I do understand that this might be the desired behavior since the name is run-time position meaning it'll only do this when the VI is first run, however I need this to happen more then once, how can i do this? Thanks...

    How did you center the FP?
    Their a method that should work time after time.
    Ton
    Free Code Capture Tool! Version 2.1.3 with comments, web-upload, back-save and snippets!
    Nederlandse LabVIEW user groep www.lvug.nl
    My LabVIEW Ideas
    LabVIEW, programming like it should be!

  • How to capture an image from my usb camera and display on my front panel

    How to capture an image from my usb camera and display on my front panel

    Install NI Vision Acquisition Software and NI IMAQ for USB and open an example.
    Christian

  • How to store character in file and display result on front panel

    hi
    currently i m working on FPGA project.i want to aquired data from FPGA board.i want to know about how to store character to file and contineous display each character on front panel in string format.
    i have complete up to character display on front panel but only single character display when i want all character in string format.
    Solved!
    Go to Solution.

    I don't see how this question is at all related to Digital I/O but it sounds like you just need a shift register with the concantanate string function.

  • Manually controlling the front panel without a keyboard

    Hi all,
    In my application I constantly switch the keyboard and the mouse between two computers (using a KVM switch), but would like to continuously be able to control a numeric control on the front panel of one of the computers (running LabView 6.1). Even if I wasn't switching, the use of the keyboard is awkward, since the control needs to be fairly effortless, quick and smooth. After searching a bit for a knob/wheel/dial type of controller, I was only able to find the new PowerMate (Griffin Technology) as a reasonable candidate, and have yet to purchase and try to integrate it. I'm also not sure how it will work with LabView.
    Am I overlooking a simple solution?
    Anyone have some experience with the Pow
    erMate?
    many thanks, Shy

    Another option: Create a simple TCP/IP application in VB or LabVIEW to
    control the control.
    That is,
    Monitor for incoming TCP/IP data in the VI with the control.
    If on your other computer you wish to make a change, just use your
    little application to do it, and send the value to the main app.
    Very cheap to do =)
    Another option 2:
    Grab the available Parallel Port digital interface design specifics for
    labview. Create yourself a simple binary switch interface. Assign 4
    bits for up and 4 bits for down.
    That is,
    sw1 = -10
    sw2 = -1
    sw3 = +1
    sw4 = +10
    Read in the digital input from the parallel port and increment your
    control accordingly. You can obviously assign any values you want to
    the digital inputs.
    Hope this helps guide you a little bit!
    Sincerel
    y,
    Jason G Richmond
    Project Engineer II and LVAAD Instructor
    VI Engineering
    [email protected] (domain should be vieng.com (no A's))
    sshoham wrote:
    > Hi all,
    >
    > In my application I constantly switch the keyboard and the mouse
    > between two computers (using a KVM switch), but would like to
    > continuously be able to control a numeric control on the front panel
    > of one of the computers (running LabView 6.1). Even if I wasn't
    > switching, the use of the keyboard is awkward, since the control needs
    > to be fairly effortless, quick and smooth. After searching a bit for a
    > knob/wheel/dial type of controller, I was only able to find the new
    > PowerMate (Griffin Technology) as a reasonable candidate, and have yet
    > to purchase and try to integrate it. I'm also not sure how it will
    > work with LabView.
    > Am I overlooking a simple solution?
    > Anyone have some experience with the PowerMate?
    >
    > many thanks, Shy

  • Audigy 1 SB0090 and CoolerMaster Centurion 5 Front Panel Au

    Hi is it possible to connect the front panel audio headers of the Cooler Master Centurion T05 casing to the Audigy SB0090 AUD_EXT header? I don't have the creative properity connecter(white connecter on top left of card) on the card.
    Thanks and hope to hear some replies soon.

    jamesroy wrote:
    how can I connect my front panel audio out and mic in to my audigy soundcard?model no. SB0090
    hope for your replies... thanks...
    Audio output:
    If you can't find a 0-pin Proprietary connector on Audigy's board then the only solution is split the signal from Front L/R cannel (it can be splitted from Rear L/R too, but you need to be able to output stereo signal to Rear L/R too (speakers set to 4/4., etc.)).
    Microphone:
    Same base rules as above but no extra settings needed.
    jutapaMessage Edited by jutapa on 05-06-2006 :37 AM

  • Just recently, Firefox has not allowed my Hotmail to open without first showing a banner that says Firefox will not open my program and I must hit the "Allow" button to get this open. Is there anything I can do about this?

    I have been using Firefox for years with Hotmail as my e-mail provider with no trouble. Now I am getting messages that say some script is running; do I want to continue or cancel and then a brown message bar will appear asking me me manually allow the opening of Hotmail. A minor annoyance yet one I have not encountered until a few months ago and would like to fix.

    See: [http://kb.mozillazine.org/Menu_differences Tools > Options] > Advanced > General : Accessibility : [ ] "Warn me when web sites try to redirect or reload the page"
    * [[Options window - Advanced panel#General_tab]]
    See also: http://kb.mozillazine.org/accessibility.blockautorefresh
    Start Firefox in [[Safe Mode]] to check if one of the add-ons is causing the problem (switch to the DEFAULT theme: Tools > Add-ons > Themes).
    * Don't make any changes on the Safe mode start window.
    See:
    * [[Troubleshooting extensions and themes]]
    * [[Troubleshooting plugins]]

Maybe you are looking for

  • Two Computers with one iPod??? I need major help!!!!

    I just got another computer, i have iTunes on my laptop with two iPods on it but i was wondering if I could set it up so that I can hook them to the new computer with the same songs and updates as the other with out it erasing my ipod. I read that u

  • Why won't photoshop elements load?

    I am having a problem loading Photoshop Elements 9.0. Everytime I click it, it's showing Error 6. Please help.

  • Can a way over-processed photo be repaired?

    Hi, I am currently using PSE8, and I have a color photo that has been 'adjusted' more times than I can count in the .JPEG format. I believe it was taken with an old NIKON 3 megapixel camera so there wasn't much color substance to start with. Long bef

  • SOLMAN_SETUP does not react

    I´ve installed a solution manager 7.1 and I start the solman_setup. The screen comes up but I can´t do anything. Are there other configurations to do before go to the setup?

  • Macking button to expand the tree and collapse tree and another to add node

    macking button to expand the tree and collapse tree and another to add node and saving the changes in the database ( this is problem) and finally delete node from database so what is proper code for those buttons thanks my mail is : [email protected]