CALLING CUSTOME ROUTINE IN VOFM FROM CUSTOMIZED SCREEN INME21N

Hi Experts,
I need to update KBETR and KWERT values present in 'Conditions Tab' in Purchase Order (ME21N/ME22N).
I have created a new customer tab in which we enter amount field and  percentage filed. When user enters some value in this and clicks on 'Conditions Tab', calculation has to be done and the calculated value has to be appeared across a specific condition type.as i am new to abap  i dont know how to create routine and pass data to routine in vofm from customised tab in me21n .
can anyone tell me how to pass data from custome screen in ME21N to VOFM routine.
                                                                                                                                                                      Thank's in advance

In transactions SMOD and CMOD, press F4
- SMOD - in the F4 select "Information System", in the pop-up window there is a "Component Name" in the "Additional Selection" block,
- CMOD - in the F4 select "Information System", in the pop-up window there is a "Exit Name" in the "Additional Selection" block,
First time you may have to change the initial display of the F4 from standard to All selection variant via the expand icon or shift-F7 (or via user settings)
Regards,
Raymond

Similar Messages

  • How to call custom screen from User exit?

    Hai,
    I have to call a custom screen from user exit include after the delivery save.
    Depends on the data in the delivery,
    if the data satisfies certain conditions I will call the screen otherwise no.
    Could any one please tell me how to do this?where to create screen & how to link it here?
    Regards,
    Bhaskar.

    Hi,
    Please check with the following Enhancements -
    V50PSTAT  - Delivery: Item Status Calculation 
    V50Q0001   - Delivery Monitor: User Exits for Filling Display Fields
    Rewards if it helps
    Regard
    Goutham

  • Calling custom screen inside a function module

    This is regarding calling a screen as a pop up from a function module.How do I capture the values that would be entered in the fields of that pop up screen?Do I use ABAP memory or SAP memory or is there any other alternative?Please suggest.

    Hi savitha,
    When you create the Custom Screen, you can attach that custom screen to the main program of the function module itslef.
    The TOP Include variables can be used as screen fields and hence you don't need to store the data entered in the screen, anywhere else.
    The data will be readily available in the global variables itself in the whole function group..
    Thanks and Regards,
    Kunjal Patel

  • How to call Custom screen in standard transaction on same session

    Hi ,
    I am getting this Problem.
      After one of the screen in standard Transaction (CV01N) I need to call one custom screen. for this I created one program type M with screen. in Stan. transaction I am calling like Call transaction 'XXXX'(for above M program).here I am geeting all my required functionality .but I am getting this custom screen in separate session. I want to call this custom screen on same session of std transaction ( means background custom screen is std.screen).
    Can any one guide me to achive this functionality;
    Regards,
    Saida.

    Hi Agasti,
      Thnx for your reply.
      I tried that method also. even that also calling the Custom screen in new session not in SAP standard session.
    Regards,
    Saida

  • Calling custom screen in VLo2n/VL03n

    Hi
    When ever user enters delivery in VL02n/VL03n, need to get one custom screen to view some information related to that particular delivery.
    Is there any user exit or badi to do this?
    Could anyone suggest the way?
    Kumar.

    Hi,
    Following are the Project and User Exits
    Enhancement/Project Name  : SLLLEG01
    User Exits                            : EXIT_SAPLSLL_LEG_CDPIR3_001
                                                 EXIT_SAPLSLL_LEG_CDPIR3_002
                                                 EXIT_SAPLSLL_LEG_CDPIR3_003
    see all the exits and which one is useful to in that include Zprg. double click
    and write your logic there, 
    I am not clear your requirement  Custom Screen to view some information means
    you want to display any popup message.
    then you can check these Function modules.
    POPUP_TO_DISPLAY_TEXT - display a two line message
    POPUP_WITH_TABLE_DISPLAY  - No. of lines you can display.
    if any doubts reply
    Regards
    Ganesh

  • How to call routine and pass data to routine in vofm

    Hi Experts,
    I need to update KBETR and KWERT values present in 'Conditions Tab' in Purchase Order (ME21N/ME22N).
    I have created a new customer tab in which we enter amount field and  percentage filed. When user enters some value in this and clicks on 'Conditions Tab', calculation has to be done and the calculated value has to be appeared across a specific condition type.as i am new to abap  i dont know how to create routine and pass data to routine in vofm from customised tab in me21n .
                                                                                                                                                                          Thank's in advance

    Hello Rajendra,
    You can get plenty of forums in SCN related to it. Follow below steps to create VOFM routine.
    Go to VOFM Transaction Code
    1. On the Menu Select required Application i.e Pricing
    2. Enter any Number in between 600 to 999 for Custom Developments.
    3. On entering Pop Screen appears ask for Access Key(We have to remember that Every New Routine needs an Access Key)
    4. Once the Access Key is received we can do modification.
    5. Enter the Routine Number ,description and insert the Access Key
    6. Now the ABAP Editor will open and required code can be copied from Standard SAP Routine and Custom Code Can be developed.
    7. Once the coding is completed we have to Activate the Routine
    8. Select the Routine and Go to Edit – Activate
    9. Ensure that Active check box is ticked upon Activation of the Routine.
    10. Double click on the routine will enter into ABAP Editor, we have to generate the Routine
    11. Go to Program and select Generate
    12.A screen pops up with the related Main Programs  and select all required main programs wherever the Routine is being called.
    13. Once the Routine is Generated and Activated, We need to configure the Routine in the config.
    ** Important SAP note: 156230.
    Check the below document too.
    http://www.scribd.com/doc/35056841/How-to-create-Requirement-Routines
    Regards,
    Thanga

  • Custom screen in a menu exit

    Hi,
    Can we call a custom screen from a menu exit?  When the menu is clicked, a custom screen should pop up . There should be a option for going back to the old screen from this custome screen.
    I have seen screen exits where u can develope custome screens but not sure whether meny exists  or function exits will allow u to call custome screen.
    regards,
    shan

    solved

  • Calling custom dialog screen from Standard Transaction(user Exit)

    Hi, I'm calling Standard Transaction from a Custom Screen. I'm calling a custom screen again with in standard transaction (implemented custom screen thru user exits using macros). But when I click 'continue/cancel' in the custom screen, control is going back to main cutom screen rather go back to standard transaction. Could anyone please help me out how to come back to standard transaction from custom screen rather going back to main cutom screen.
    ***INCLUDE LZ_R_FORWARD_FORWARD_LOADI01 .
    *&      Module  USER_COMMAND_9000  INPUT
    MODULE user_command_9000 INPUT.
      CASE sy-ucomm.
        WHEN 'EXEC'.
          PERFORM validate_popup_data.
          IF flag_error_screen NE 'X'.
            MOVE-CORRESPONDING ZFFL_POPUP to var_ZFFL_POPUP.
            clear flag_return.
            SET SCREEN 0.
            LEAVE SCREEN.
          ENDIF.
        WHEN 'CANC'.
          flag_return = 'X'.
          SET SCREEN 0.
          LEAVE SCREEN.
        WHEN OTHERS.
      ENDCASE.
    ENDMODULE.                 " USER_COMMAND_9000  INPUT
    *&      Module  exit_9000  INPUT
    MODULE exit_9000 INPUT.
      CASE sy-ucomm.
        WHEN 'CANC'.
    *      MOVE perf_flag TO lbpla_exist_flag.
          flag_return = 'X'.
          SET SCREEN 0.
          LEAVE SCREEN.
      ENDCASE.
    ENDMODULE.                 " exit_9000  INPUT
    Thanks in advance.

    Hi
    So the command SET SCREEN 0. LEAVE SCREEN. should "place" the program just after the calling of the popup so here:
    FUNCTION z_call_screen.
    * Call the Pop up screen
        CALL SCREEN 9000 STARTING AT 35 05.
    "<------------------------- The program should be here after going back from popup 9000
    ENDFUNCTION.
    Is it true?
    Max

  • 6th generation nano screen black but able to touch screen from memory to get music to play..called customer support they said it's the backlight since touch screen can still be touched and music can be played..any thoughts?

    second 6th generation nano..again with the same problem..screen is black will not turn on but am able to touch screen and get music/radio to play...able to touch around on screen from memory..nano is recognized in itunes and computer..but screen will not turn on..called customer support today..of course out of warranty but was told that it sounds like my backlight is burnt out and that's all i need fixed, told that it shouldn't be that expensive (live in myrtle beach SC) and that my screen is fine since i am able to touch around on it...any thoughts?
    thanks to all for any advice or input..will try to take to local icitymac store in next couple of days
    jenn

    Replacing the backlight usually requires replacing the entire front LCD/digitizer.  And yes, it sounds the backlight has burned out.
    Keep in mind that if you go the Apple route, they won't actually repair the iPod, but instead will do an out of warranty exchange meaning your current Nano will be replaced with a refurbished model of the same capacity and generation.
    B-rock

  • How to call a Custom screen in portal from a Poratal UWL ??

    How to display a Custom screen which is developed in portal when a work item is executed through the
    portal-UWL ?.
      In detail....
         A custom screen has been developed in portals.
    Workflow triggers when a new item is created on the custom screen then the workitem gets populated in the respective approver Portal UWL(universal work list).
    when the workitem is executed from the UWL then it has to display the custom screen with its header data on the portal.

    Hi sampath,
    Thanks. I found that the redirection is not working
    properly at IIS end and changed the configuaration to
    make it work.
    Thanks a lot,
    Gopi

  • How to get the screen value to custom screen from standard screen

    Hi all,
    I have a standard screen which is attached to a standard function group and a custom screen which is attached to a custom function group... Now my requirement is to get some field values from the Std screen to my custom screen ...
    I have used the FM DYNP_VALUES_READ but its resuts in error...
    in my current screen PBO i called this FM and given the prog name as the Std pgm name which being created while creating the screen from the function group and the screen number as the standard screen number...
    Eg : Standard Function gp = FSBP_02
           Pgm name  = SAPLFSBP_02
          Screen Naumber = 0220
    Custom screen = 9001
    Pgn Name = zname
    in 9001 PBo i called
    DATA: IT_DYNPFIELDS  TYPE TABLE OF DYNPREAD,
           WA_DYNPFIELDS like line of IT_DYNPFIELDS.
    WA_DYNPFIELDS-FIELDNAME = 'BP021-BUSINESS_Y'.
    APPEND WA_DYNPFIELDS TO IT_DYNPFIELDS.
    CALL FUNCTION 'DYNP_VALUES_READ'
       EXPORTING
         DYNAME                               = 'SAPLFSBP_02'
         DYNUMB                               = '0220'
        TRANSLATE_TO_UPPER                   = ' '
        REQUEST                              = ' '
        PERFORM_CONVERSION_EXITS             = ' '
        PERFORM_INPUT_CONVERSION             = ' '
        DETERMINE_LOOP_INDEX                 = ' '
        START_SEARCH_IN_CURRENT_SCREEN       = ' '
        START_SEARCH_IN_MAIN_SCREEN          = ' '
        START_SEARCH_IN_STACKED_SCREEN       = ' '
        START_SEARCH_ON_SCR_STACKPOS         = ' '
        SEARCH_OWN_SUBSCREENS_FIRST          = ' '
        SEARCHPATH_OF_SUBSCREEN_AREAS        = ' '
       TABLES
         DYNPFIELDS                           = IT_DYNPFIELDS
      EXCEPTIONS
        INVALID_ABAPWORKAREA                 = 1
        INVALID_DYNPROFIELD                  = 2
        INVALID_DYNPRONAME                   = 3
        INVALID_DYNPRONUMMER                 = 4
        INVALID_REQUEST                      = 5
        NO_FIELDDESCRIPTION                  = 6
        INVALID_PARAMETER                    = 7
        UNDEFIND_ERROR                       = 8
        DOUBLE_CONVERSION                    = 9
        STEPL_NOT_FOUND                      = 10
        OTHERS                               = 11
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    How Can i get that... Its important ... Please help me...

    Hi,
        Try with the below FM
    RS_REFRESH_FROM_SELECTOPTIONS
    in your custorm program, check the SY-CPROG and SY-XPROG values, for the standard program name or directly pass the importing parameter for the above FM as SAPLFSBP_02.
    Regards
    Bala Krishna

  • RESCIS - Unable to select custom report from Selection Screen

    Hi all,
    we have developed a custom report for transaction "RESCIS-Evaluation of service charge settlement" but we have found that althought the report appears in selection screen field called "REPORT" it throws message RESCIS003 but the report is not shown.
    If we doesn't fulfill report field in selection screen, the program shows a second screen where a couple of ALVGrids are shown allowing the user to select the report that will be displayed. Here we are able to select our custom report and the data in it is displayed.
    We have analyzed the standard program that is executed via transaction RESCIS and we've found that the selection screen executes standard function RESC_GUI_ANYREPORTS_APPL that doesn't executes reports dinamically but statically. That means that SAP doesn't allows to execute custom reports directly from selection screen.
    I think this is a SAP error but afert opening an OSS message SAP sais that is not an error but a bad configuration or lack of knowledge for customizing it.
    Has anyone developed a custom report for RESCIS transaction?

    Hm what exactly did you want to change? Normally it is in REFX cases you should not copy standard REPORTS. In your case with transaction RESCIS, I myself do not see any need to add any functionality in this report because it is only a sum of all lists from your service charge settlement. What else do you want to see there?
    For displaying new fields in the separate lists maybe there is some BADI for it.
    Regards
    Michael

  • How to call custom BSP application (copied from standard)

    Hi,
    I came across 1 interesting link in SDN.
    [Enhancement procedure of BSP application HRRCF_RECRUITER in eRecruitment]
    My requirement is also similar.
    I need to copy the HRRCF_TRM_SRCH application.
    I know how to make the changes for the logic (like copying the standard controller & iterator class etc.)
    But I donu2019t know how to call the custom BSP application.
    One requirement is, I need to call a BSP application, in which there are only UI(user interface/screen) changes .
    That is, if there are only changes made to hitlist_cand.bsp page . And no changes made to hitlist_cand.do page.
    Eg: Removing one button from screen.
    Second requirement is, I need to call a BSP application in which there are logic changes also.
    (I know how to  change the standard controller class to custom class)
    Eg: Changing logic of button.
    We tried renaming the application name from standard to custom one (with Namespace=SAP itself, though it gave a warning) in the table T77RCF_LOG_APPL .
    Then we used this name to configure the start page link. But still the execution control is going to standard page & not to custom BSP application.
    How will I know which BSP application(Appl A), is calling the BSP application (Appl B) in which I want to make changes ?
    The starting application is HRRCF_START_INT.
    Would really appreciate solutions posted.
    Thanks,
    Nisha Vengal.

    Hi Nisha,
    I think you have an issue to call custom BSP.
    -     Ignore the warning message (in the table T77RCF_LOG_APPL) as it is just a warning message. I did not touch start page link at all.
    -     Additionally you need to make (I had to made) an entry in table u2018V77RCF_SMG_NAVIu2019.
    Let me know, if you need anything else.
    ...Naddy

  • Is it possible to call the Print Quote functionality from Custom ADF page

    Hi,
    We are researching if it is possible to call the Print Quote functionality from the Custom ADF application.
    Goal is to pop up the PDF report upon clicking the Print Quote button on the custom page. Is it possible ?
    Atleast advice on the direction to go forward is appreciated.
    Thanks
    Sai

    Hi ,
    Please check following thread on forum -
    Re: ADF: Calling OAF Page from ADF page
    Check this may also be useful-
    https://blogs.oracle.com/shay/entry/to_adf_or_oaf_or
    I have not tried yet but Steven Chan (Sr. Director OATG) suggest following methodolgy for this-
    https://blogs.oracle.com/stevenChan/entry/appsdatasource_jaas_ebs
    Thanks,
    Ashish

  • Is it possible to call custom designed RFC function module, apart from BAPI

    Hi Friends,
    1.     Is it possible to call custom designed RFC function module, apart from BAPI.
    2.     Why we call it Adaptive RFC layer, Since every time the JCO layer updated with SAP, Why can’t be dynamic.
    Thanx for Ur time.
    Cheers,
    Sam

    Also check <a href="http://help.sap.com/saphelp_nw04/helpdata/en/41/38bc8f813719488ddc9d9b21251ec3/frameset.htm">here</a> for more information on aRFC. Here you can find why it is called adaptive.
    Regards,
    Christophe

Maybe you are looking for

  • Embed a font in one SWF use in another?

    Long version: I've got a "player" app that I've built that shows content from various XML files. I have certain common fonts embedded in it (Verdana, Arial, Times, etc.) that it uses to display text. Now, I've got a client with a special symbol font

  • Fields not displaying on page 2 (sometimes page 1)

    CR11 Please bear with me as I'm relatively new to this... I'm working on a report that has multiple records in one report (a batch of purchase orders).  The formating is quite basic, no extensive formulas.  It has "reset page after" formatiing as wel

  • Recommended size for .SWF on website???

    Hi there, I'm producing an interactive video piece for my New Media masters project.  I've put it up on my website, and was wondering out of curiousity, whats the recommended upper limit for the size of a .SWF file on the internet to run smoothly? I

  • Oracle 10g on Win Vista, XP

    Hi, Could anyone please let me know if I can install Oracle 10g on the following Operating Systems:- 1) windows XP Home Edition with Service Pack 2 2) Windows Vista Home Premimum ????? Please let me know. Thanks

  • CS5 Upgrade - Student Edition?

    Currently, Adobe is only listing a student edition upgrade for Photoshop Extended. At least as far as I can see. Can one expect to see a student edition of Photoshop CS5 (cooking) at some future point? Maybe after CS5 ships?