Can I measure Vibrating Wire Strain Gauges using Field Point Inputs?

Is wish to connect a Vibrating Wire Strain Gauge using Field Point.
The sensor requires a swept frequency excitation (typically 400 to 1500 Hz) and then generates a frequency output proportional to the strain applied on the vibrating element. The frequency (roughly upto 1kHz) needs to be measured.

What sort of resolution is needed on the frequency sweeping? There are currently four FieldPoint modules that can be used for generating pulsed outputs; the FP-CTR-500, FP-CTR-502, FP-PWM-520 and FP-PG-522. For the remained of this posting, I will use FP-CTR-50X to represent both the FP-CTR-500 and FP-CTR-502 as they are identical in functionality, different in their input/output stages.
The FP-PWM-520 is a Pulse Width Modulation output with 12 bit resolution on duty cycle and 16 bit resolution on the pulse period. The period is adjustable from 1 to 655535 milliseconds, which makes the module slightly less than ideal for frequency sweeping as it's highest frequency is 1 kHz and it's second highest frequency is 500 Hz.
The FP-PG-522 is a Pulse Generator module that can operate in an continuous pulse mode. The On Time, Off Time and resolution (time base) are adjustable. The smallest time base is 100 ms, for a maximum output frequency of 5 kHz. Like the FP-PWM-520, the FP-PG-522 adjusts it's output rates by changing the time rather than the frequncy, making it difficult to smoothly sweep across frequencies.
Finally, the FP-CTR-50X modules may be used. The FP-CTR-50X modules have 8 16 bit counters, 4 Gates and 4 outputs. The module has two internal clocks, 1 kHz ad 32 kHz that can be used to feed the counters. The outputs can be configured to toggle each time an adjustable terminal count is reached, allowing output pulse generation of up to 16 kHz (32 kHz internal clock divided by 2). The FP-CTR-50X modules have the advantage over the above modules in that the counters can be cascaded and set for differing terminal counts allowing multiple pre-scalers which may allow better resolution of generated frequncies.
For measuring the output frequency generated by the gauge, the only current modules that will allow you to directly measure the output are the FP-CTR-50X modules. However, as they were primarily designed for event counting, it takes a little bit of extra programming to allow them to be used to measure frequencies. The effectiveness of frequency measurement on the FP-CTR-50X modules varies on the sampling period, the programming and the network module. There are several KnowledgeBase and Developer Exchange articles talking about how to use a FP-CTR-50X module to measure frequencies, so I will not duplicate the information in this post.
Regards,
Aaron

Similar Messages

  • How can I measure selected area of pixels using photoshop elements 12?

    how can I measure selected area of pixels using photoshop elements 12?

    Show the 'information' panel F8).
    In the middle horizontal section, select 'pixels' on the left drop-down menu.
    Use the rectangular marquee tool to select your area: the dimensions in pixels of the rectangle is shown under 'dimensions' on the right.
    I think there are other ways to measure a line segment, but you could use the above measure by adjusting the rectangular marquee tools to both extremities of the segment,
    - use the move tool to rotate the rectangle so that the diagonal measuring the segment is horizontal,
    - move the rectangle to the left, and check validate, which creates another rectangle including the first one
    - read the pixel dimension (L:) in the info panel like above.

  • I have a FP-1600 and a FP-AO-200 module, 0-20 ma. When I use Field Point Explorer 3.0.1, I can not command any of the channel output current. The current remains in the lowest value 0.0035 A. What is the problem ?

    I have a FP-1600 and a FP-AO-200 module, 0-20 ma. When I use Field Point Explorer 3.0.1, I can not command any of the channel output current. The current remains in the lowest value 0.0035 A. What is the problem ? The communications with the module are OK, because it shows when the current are open or closed.

    Jorg,
    I noticed that you claimed to be using the module in 0-20mA mode, yet the reading you are seeing is 3.5mA. This is the minimum value (with overranging) when the module is set to 4-20mA mode. My guess is that your module is defaulting back to 4-20mA mode, but your IAK file still thinks the module is in 0-20mA mode. You can verify this by using the find devices button in FieldPoint Explorer and then trying to write to the channel.
    To fix this problem, you should use the snapshot feature to change the default power-up mode for that channel.
    Regards,
    Michael Shasteen
    Applications Engineering
    National Instruments
    www.ni.com/ask
    1-866-ASK-MY-NI

  • Can I collect the pulse data using Field Point?

    I have a water flow meter, which outputs pulses. I use a counter to connect it and read the data. Now, I want to read and save the data in the computer using LabView and Field Point. I think this can be done if I can collect the number of pulse. I am wondering how to do that.
    Thanks.

    Dear Zl,
    Counting pulses is much easier with the FP-QUAD-510 or FP-CTR-500, but can be done with the FP-AI-110.  You can't directly count the pulses with a FP-AI-110, but you can do it in software. Bring in the data by doing a normal read. Then, using shift registers, if the previous voltage is less than .8V (low) and the current voltage is more than 2.5 (high), increase the pulse count. I have attached a program that shows what to do with the data once you bring it in. I took the data from an array outside the while loop, but your data will be brought in one point at a time inside the while loop. One thing to take note of, since Fieldpoint brings in data at 1 kS/s, this will only work with pulses slower than 500 Hz. The farther the duty cycle is away from 50% duty cycle, the slower the signal must be in order to catch the pulses correctly. Please let me know if you have any questions. Have a great day!
    Sincerely,
    Marni
    PS- Please only post question once.
    Attachments:
    pulsecount.vi ‏22 KB

  • Using field points how the dc voltage measurement is done?

    i am new to labVIEW.. Using cFP-AI 100 i am trying to measure a dc voltage [5volts].. all the field point channels are configured on MAX. when the example VI provided runs with the proper i/o point is selected] there is error indicating that the connection is broken or network module is not pwered on.. but i have checked both .. What may be the problem?

    Hi ELUE,
    Could you please let me know if the status LED (or any other LEDs are blinking) in a particular pattern on your fieldpoint controller? Also, could you please let me know what controller you are using and if you get a particular error code? Thanks!
    Best regards,
    Steven

  • Using field points how the dc voltage measuremen​t is done?

    i am new to labVIEW..  Using cFP-AI 100  i am trying to measure a dc voltage [5volts].. all the field point items are configured on MAX. when the example VI provided runs there is error indicating that the connection is broken or network module is not pwered on.. but i have checked both .. What may be the problem?

    Hi ELUE,
    When you say "all the FP items are configured on MAX," does that mean you can see and connect to the device? Can you take readings in MAX from the FieldPoint module I/O menu under the Data Neighborhood?
    If you're able to read from the I/O menu you are probably using the default I/O point in the example. It's usually necessary to choose the I/O point before running the example.
    Cheers.
    | Michael K | Project Manager | LabVIEW R&D | National Instruments |

  • Tips on transferring LV executable that uses Field Point Serial to another PC

    I have been trying to transfer an LabVIEW compiled executable  from one PC to another
    The executable references 2 field point serial banks.
    After hours of frustration I think I have it pinned it down to the fact that (at least for me) It is not possible unless LabVIEW is invoked on the target machine.
    Only if I start LV 2010 and configure a field point control on it then LabVIEW can refer to the Bank. After that I can have it refer to the correct IAK file and the executable will work. 
    However IF I try to transfer from another machine without starting LabVIEW on the target machine it simply will not work for me.
    It seems that I have to load a FIeld point control on a block diagram of a new machine then configure it to get dialogs to come up specifying
    how to select the proper configuration. I do not see any of this help in MAX
    Id much rather have a way of setting up in MAX than having my EXE work right away. Instead my workaround is to
    start LabVIEW and configure a field point control to get it set up proiperly.
    This means I may have to install yet another version of LabVIEw to get the exe to work again and its getting tiresome.
    I use INI files for the serial port settings. Its the field point software that has me going in circles.
    If anyone have any experience or tips for transferring an executable that uses fieldpoint serial (FP-1000) from one PC to another PC
    without having to invoke LabVIEW to configureit I would be interested in hearing from you. Thanks
    PS Target machine has LV2010   MAV ver 4.70f4
    Executable compiled in LV 2010
    Source Machine has LV 2010 SP1  MAX ver 4.7.6
    Executable compiled in LV 2010 SP1
    My next move is to upgrade the target to 2010 SP1 and try again but it has already taken me days to transfer this one program
    and I still cant figure out how to do it so I might just wait and see if there is any interest in helping me first.
    Thanks again!

    I have been to these KnowledgeBase links and what is so frustrating about it is that I have have not seen anything that was not already done
    automatically when I created the executable on the source machine and transferred the executable to the target machine.
    http://digital.ni.com/public.nsf/allkb/734179A2A6779C4286256C4C0069C5F4
    http://digital.ni.com/public.nsf/allkb/2DC46E07FAA0A5EF86256F35006E9AE5
    http://digital.ni.com/public.nsf/allkb/0E9001A8C84CD89486256DE80073F198
    MY FP version is 6.07 on both machines.
    The dll is where its supposed to be on the target machine in a Data subfolder under the main application (exe) folder
    The IAK file is created in MAX with the designations identical to what is the source machine.
    The EXE is now partially working (somehow) but I am trying to find out the exact procedure for next time so I can write it down for future reference..
    EVen though the target application now 'sees' the Field point banks the utility I added into the exe to allow user to configure a front panel Field Point control
    (should it be required) does not work. Instead when I try to browse configure the control in the executable I now get this error dialog.
    This must be the root of all my troubles.
    I am now attempting to resolve this by installing LV2010 SP1  and DCD_NOV10 on the target machine so that it matches the source machine.
    (If I am going to re-install Fieldpoint I might as well install the whole Device Driver CD)
    I hope this solves this issue once and for all.
    Your knowledge base insists that if the field point versions are the same on both machines and if the DLL is where it is supposed to be and if the IAK file is loaded and saved
    this should work. It did not and still does not fully work. If I can find the exact reason I will report it in this thread.
    Attachments:
    ni-FP-error.GIF ‏16 KB

  • I have problem in transfeering data using field point via tcp

    I am reading the values from the filed point, which is connected, to the RT controller and transferring the values to the client PC via TCP at a specified acquisition rate.
     Case1 when the acquisition rate is 0.1 minutes I get the values from the controller correctly i.e. 5v, 5v, and the chart shows no change. The timed out of the TCP read is default value i.e. is 250ms
     But when I change the acquisition rate to .5 minutes I get the values as 5v, 0v, 5v, and 0v. The time out of the TCP read is same as first case. The inputs to the field point are at the constant 5v.
    Please tell how to solve the problem so as to see the plot in the chart continuously as inputs for the field points the read
    ing are at constant rate of input 5v.

    Suresh,
    Since this question deals with using the LabVIEW TCP/IP functions, you are better off posting it to the LabVIEW discussion forum.
    Regards,
    Aaron

  • How can I measure coherence between EEG signals using labview?

    well, I have an EEG signal(a matrix 16X8498)whose lines represent the channels and collums the samples. The last line is the stimulus channel. I would like to know if I can measure the coherence between my EEG channels(lines)using labview.If,yes,is there someone who has the block diagram?

    Search the Labview help for coherence and you'll find several functions (in Labview 6.1 Full Development System). The functions are in the palette Analyze >> Waveform Measurements >> Frequency Response Function (Mag-Phase) or (Real-Im).

  • How can i measure SNR(S/N)value using FSP Spectrum analyser

    hi ,
     I want to measure S/N value using spectrum analyser.i already installed rsspecan instrument driver.I also configured span,center frequency ,RBW,VBW etc but i am not able to get measured S/N value.I have attached my vi here with.how could i measure SNR Ratio??can you please help me!
    thanks.
    Tadhika
    Attachments:
    Unbenannt 1.vi ‏77 KB

    Hi, first of all I'd recommend to contact the R&S customer support center to be shure the measure the correct value. Did you really measure the actual noise, or do you measure the noise which is "only" displayed?
    But anyway, did you have had a look at this example: http://www2.rohde-schwarz.com/file/rsspecan_lv8_noise_marker_example.zip
    There is the setup of one noise marker shown. With your already existing marker value this should do the trick, also in case of two noise markers; just use the rsspecan Configure Marker Noise Measurement.vi again with input parameter <YourMarker+1> of the "Marker" input of the VI.
    Hope that helps?
    juergen

  • How to wire up and use 256 points at a time on the PXI-2532

    I have a PXI chassis with a PXI-2532 512-Crosspoint Matrix Switch Module, a TB-2640 connected to it, and a PXI-4072 FlexDMM and LCR meter.
    I am trying to use the DMM to make measurements of something connected to the switch matrix.  What I can't seem to figure out, is since the matrix is a 1 wire 4x128 matrix, how do you connect 256 points when there are only 128 conductors in the ribbon cables that attach to the 2640?  There are 2 banks of 8, each with 16-pins, on the TB-2640, that seem to be wired internally together.  I would like to utilize 256 points in the 512 matrix at a time, and currently I have the DMM hooked up to r0 and r1 to take the measurements.  How would I hook up r2 and r3, in the same matrix?
    If you are really confused I can explain further, but I haven't found anything that shows how you would actually connect 256 wires to the 2532, when there are only 128 columns.  Any information helps.
    Thank you.

    Since the matrix is a 4x128, there are 4 rows and 128 columns to which you can connect devices under test (DUTs). You can not connect 256 different DUTs because there are not 256 connections. The points refer to the switches inside the card rather than the actual signals. 
    Here's a bit more info:
    http://www.ni.com/white-paper/4453/en#toc3
    Also I would post future switch questions here:
    http://forums.ni.com/t5/Switch-Hardware-and-Software/bd-p/320
    I hope this helps,
    Eric E.

  • When using field point I/O points i get error message

    when labview 1st loads and i open my FP vi which uses FP I/O points to specify the channels, they are all greyed out and the error "unable to bind to comm port" is returned. on running the program a second time, no errors are returned. also i cannot get an executable of the program to run without producing that error.
    Any ideas?

    Hi Stewbert,
    The "Unable to bind to COM port" error indicates that FieldPoint Explorer cannot use the specified COM port for communication. The two general cases that cause this error are that either the COM port is not configured properly or does not exist, or that the COM port is already in use by another program. To check the COM port and eliminate this error, follow the steps below.
    First, quit all other applications that may use the COM port. Note that the serial cradles for the popular Palm or Handspring Personal Digital Assistants (PDAs) can connect over a serial port, and therefore you may need to quit the "Hot-Sync Manager" program if your computer is configured to use a Palm.
    If closing all other programs that use the COM port does not elimin
    ate the error, then next check that the COM port is configured properly. From the Windows task bar, Select "Start >> Settings >> Control Panel >> System >> Device Manager >> Ports". Confirm that the COM port you have specified is in the list, and that Windows indicates that "the device is working properly". Additionally, if the COM port has been added through additional hardware, then use any available diagnostic utility that may have come with the board to test the COM ports. For example, if the COM port is added through a NI-Serial board (PCI-232, etc), then selecting "Start >> Programs >> National Instruments >> NI-Serial >> Diagnostic" will run a diagnostic of those COM ports. Correct any problems that are found, and then continue with configuration in FieldPoint Explorer.
    Please let me know if that helps
    Thanks
    Sacha Emery
    National Instruments (UK)
    // it takes almost no time to rate an answer

  • I am using field point to replacement plc, i need to control stepper motor by using field point, what module should i buy and how to control it?

    Can i use FP-PG-522 or FP-PWM-520 to control the stepper motor.

    Cheeking,
    I think Aaron has answered this query at: http://exchange.ni.com/servlet/ProcessRequest?RHIVEID=101&RPAGEID=135&HOID=506500000008000000E16E0000&UCATEGORY_0=_49_%24_6_&UCATEGORY_S=0
    Pravin

  • Help : use field point module

    Suite à de très gros problèmes avec mon système d’acquisition de données, j’ai besoin d’aide. Pour résumer la situation avec un langage non technique (mes compétences ne me permettent pas de plus amples détails) je dispose de plusieurs modules fieldpoint : FP2010, FPTC120, FPAI111, FPAO200.
    Dans un premier temps j’ai voulu faire communiquer en local mon pc et mes modules via un câble Ethernet croisé. En vain, le Pc n’a jamais voulu reconnaître le boîtier central (pourquoi ?). De ce fait je me suis créée une adresse Ip et à ce niveau mon module FP2010 communiquait mais les autres systèmes n’étaient pas reconnu malgré le fait que la led ‘ready’ était éclairée. J’ai donc essayé de faire un reset au module fp2010 et depuis aucun module ne fonctionne. En fait la led status clignote en permanence et je n’arrive plus à faire de liaisons (en local ou sur réseau)…
    Je pense avoir essayé toutes les solutions et je suis donc bloquée ne sachant plus comment m’y prendre.
    Si vous avez des conseils, je suis preneuse. Merci d’avance.
    Ophélie Bouzon (Université de Savoie)

    Bonjour Ophelie,
    Ca a l'air d'être un problème d'installation du FP-2010.
    Je vous conseille de bien lire les documents ci-dessous :
    *** Troubleshooting Communication Problems with the FieldPoint Ethernet Network Modules
    http://zone.ni.com/devzone/conceptd.nsf/webmain/49​e7983a1c47a3af86256a3a005b4a3e
    *** Connecting a Fieldpoint Controller Directly to an Ethernet Card
    http://digital.ni.com/public.nsf/websearch/DF05D39​E13B3AC4B862569B60055B6DC?OpenDocument
    *** Le "User Manual" du FP-2010 où on explique de manière détaillée comment configurer et installer un FP-2010 :
    http://digital.ni.com/manuals.nsf/websearch/B31455​BC0C2746DA86256CEE0078354D?opendocument
    J'espère que cela vous aidera à avancer et résoudre votre problème.
    Cordialement,
    Sanaa T
    National Instruments France
    Sanaa T.
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    >> http://www.nidays.fr/images/081110_ban_nidays09_468X60.gif

  • How to measure voltage changes using a NI-9219 with strain gauges and use the data in labview

    I am updating an old LabView/Data Acquisition system that uses strain gauges to measure two forces (normal and axial) as well as two moments (Pitch and Roll). I am having trouble reading the voltage changes over my strain gauges using my NI-9219 as well as filtering the data with both a lowpass and smoothing filter. The program attached has the project and should have all the sub-vi's used in the program. This program was written on LabView version 8.5 and is being updated to a 2013 version of LabView. Also, the hardware previously used was a combination of a NI SCB-68 and NI USB-6251. If anyone could help me it would be greatly appreciated! 
    Attachments:
    New SSWT.zip ‏751 KB

    Hi Coffeyfj, 
    Did you ever had this set up working? The first thing that I would do as I mentioned in the previous comment would be to use one of the LabVIEW examples. I recommended to you using the (strain - Continuous Input.vi). If you can read any voltage changes with the example vi, then we will know the problem we are having is in your code. If you cannot read any voltage changes using the example I mentioned, we can start trouble shooting the hardware connections. Are you connecting the excitation voltage? If yes, Are you making the right connections. Please refer to page 19 of the following document (half and full bridge modes)
    NI 9219 Operating Instructions and Specifications - February 2009
    http://digital.ni.com/manuals.nsf/websearch/4197ED4BD126E0B486257546005851CA
    Regards,
    William Fernandez
    Applications Engineer 
    National Instruments 

Maybe you are looking for

  • I just installed Yosemite on to my MacBook Pro

    I just installed Yosemite on to my MacBook Pro and I have noticed that my computer has slowed down, I now start working and all of a sudden, the cursor turns into the little round colored circle and the system "stalls" for a bit. My favorite bookmark

  • Installing Adobe Document Services

    We are in the process of installing Adobe Document Services and we are on ECC6.0 system. I have question is there any requirement that we need to upgrade our ECC system from Ecc6.0 to  SAP ERP 6.0 EHP4 . ======== component information=========== soft

  • Macbook Pro High Res Screen getting White Spot/Mura

    I have 2012 MBP with the High res screen. Bought it back in August. I noticed today that I see a little mura/white spot devloping in the screen. Its not noticeable on dark backgrounds, only light colors. But on light colors, its very noticeble. Im st

  • Steps to setup and configure Node Manager on local and remote machine

    Hello, I am using WLS 10.3 on Windows. I have two machines, One cluster and two managed servers (one on each machine) created under a domain. I have used configuration wizard to create the domain. I have gone through documents on Node Manager and fou

  • How to call dicoverer through menu option in forms

    Hi, Need help.........Can anybody tell me .....how to call dicoverer through menu option in forms. Thanx Sunil