Change DB_NAME failed with NID-00133: Database should have only consistent.

I have created two testing database for active data guard with Oracle 11g on Linux. I created standby DB by using rman backup from primary database. Now I want to change DB_NAME of standby database. I used DBNEWID utility
%> nid TARGET=SYS DBNAME=newname SETNAME=YES
It generated the error like this
NID-00133: Database should have only consistent datafiles
Change of database name failed during validation - database is intact
Many datafiles even system datafiles are not consistent. I shutdown DB and startup mount again and tried again. It all failed with the same errors. I searched solutions on Oracle Support web and other twchincal web and couldn't find
answers. Please help me to get the solutions. Thanks.

Thank each of you so much for your inputs.
Yes, based on oracle document, primary and standby shouid use the same name. But they can have different db_unique_name or instance_name. I created standby by using Grid Control. It automatically assign the same DB_NAME.
I modified db_unique_name. However, our PeopleSoft admin needs to connect to two databases to do testing. PeopleSoft version only support the different DB Name and DB Name cannot be over 8 characters. This is why I tried to
change DB_NAME to meet PeopleSoft Admin's requirement. I think, in the real world for data guard configuration, primary and standby should have the same db_name.

Similar Messages

  • Change DB_NAME error with nid (NID-00135)

    I use the nid to change the DB_NAME but it always return the following error:
    NID-00135: there is 1 active threads
    What I do is, in dos prompt
    use sqlplus
    shutdown immediate;
    startup mount;
    exit;nid target system/password@OLDNAME DBNAME=NEWNAME SETNAME=YES
    My environment is
    Oracle 10.2.0.3 RAC in window environment.
    Can anyone help ? Thanks !

    NID-00135: There are number active threads
    Cause: is that the database crashed the last time it was shut down.
    Action: Ensure that all threads are closed before retrying the operation. Start and open the database to perform crash recovery, then shut down with the NORMAL or IMMEDIATE options to close it cleanly. Finally, try running the utility again.
    Is it possible, second instance is still running?
    Werner

  • I changed my data plan yesterday. I should have set it to change at the new month which is tomorrow. can i fix this?

    I changed my data plan yesterday. I should have set it to change at the new month which is tomorrow. can i fix this?

    I don't know if they'll be able to change it or not, but it's worth calling Customer Service ASAP (since you indicate your billing cycle starts tomorrow, so that would be midnight tonight) and asking.
    Customer Service
    Dial *611 from a cell phone
    (800) 922-0204
    Monday - Sunday 6 am - 11 pm

  • Has anyone come up with criteria on who should have an iPad at work?

    Has anyone come up with criteria on who should have an iPad at work?

    I'm in health care as well...the executives will probably be the first to get them since they are the ones that sign the invoices.....but seriously the iPad has  a number of uses in health care...patient education, display of real time clinical data through a vpn connection and in-house apps, desktop virtualization etc.  I really believe if you can get the devices in the hands of clinicians, they will think of innovative ways to use them for far more than email, contacts, calendars etc.... 

  • I'm having trouble with my macbook pro, I have only had it for three months, when I plugged a camera sd card into the sd slot it isn't appearing anywhere on the computer and i can not access my photographs. can somebody please help me?

    I'm having trouble with my macbook pro, I have only had it for three months, when I plugged a camera sd card into the sd slot it isn't appearing anywhere on the computer and i can not access my photographs. can somebody please help me?

    Shootist007 wrote:
    Clifton I must disagree with you on the above statement. It is my opinion and experience that you should never connect the camera directly to any computer, Mac Windows Whatever.
    It is always best to Remove the memory card from the camera and put it in a card reader, whether an external reader or one built into the computer, to copy images from the card.
    Hi Shootist. I would be interested in hearing some reasoning on this. I almost always use a USB cable to connect my camera to the MBP for transferring pictures, and have moved about 30,000 this way over the last 6 years since my photography went digital. Recently, on the rare occassions when I have only a few to transfer and I was too lazy to go for the cable, I have used the card reader; about half those times I have difficulty getting the MBP to recognise the card. I find I have to press the card very hard into the slot for it to be recognised.
    My rationale is quite possibly wrong, but I feel that the USB connectors are more robust and hard-wearing than the flimsy connectors on an SD card. Also, I haven't measured it, but I think the data transfer is faster with the cable. (I just came across this test, which reports noticeably faster transfer for cable than built-in card reader, but the computer was a PC)
    Chiara, sorry for hijacking your thread.

  • Sharepoint infopath form should have only new item rights

    Sharepoint infopath form should have only new item rights

    You may create a custom Permission level for this requirement. Go to Site Settings -> User And Permissions -> Site Permissions -> Click on Permissions Tab in the ribbon. Now click on Permission Levels. Click on Add a Permission level.
    Give name to this new permission level. In the List Permissions, Check Edit items and keep "Add items" unchecked. Select other permissions which you need to give. Save the Permission level. Now assign this permission level to the group. Note that,
    you can also change the OOB permission levels like "Contribute" and uncheck "Add Items" permission but that may have an undesirable effect on other things. It is always better not to change OOB things.
    Blog | SharePoint Learnings CodePlex Tools |
    Export Version History To Excel |
    Autocomplete Lookup Field

  • Bug CSCud93686 - Change password fails with AC on Windows 8 and 7

    Bug CSCud93686 is currently locked because it contains proprietary information.  This bug is fixed in the most recent release of AnyConnect Secure Mobility Client and I am interested in the full details because we have had issues implementing the password management feature in our environment.  Can anyone provide me with more details on this bug?
    Thanks

    Incidentally the link that this mentioned in the log file works fine when I open it in Internet Explorer:
    2014-03-18 12:04:16:095 1076 1830 SLS Retrieving SLS response from server...
    2014-03-18 12:04:16:095 1076 1830 SLS Making request with URL HTTPS://sls.update.microsoft.com/SLS/{9482F4B4-E343-43B6-B170-9A65BC822C77}/x64/6.3.9600.0/0?CH=41&L=en-GB;de-DE;nl-NL&P=&PT=0x30&WUA=7.9.9600.16422
    2014-03-18 12:04:16:237 1076 1830 Misc WARNING: Send failed with hr = 80072efe.
    2014-03-18 12:04:16:237 1076 1830 Misc WARNING: Proxy List used: <(null)> Bypass List used : <(null)> Auth Schemes used : <None>
    2014-03-18 12:04:16:237 1076 1830 Misc WARNING: Send request failed, hr:0x80072efe
    2014-03-18 12:04:16:237 1076 1830 Misc WARNING: WinHttp: SendRequestUsingProxy failed for <HTTPS://sls.update.microsoft.com/SLS/{9482F4B4-E343-43B6-B170-9A65BC822C77}/x64/6.3.9600.0/0?CH=41&L=en-GB;de-DE;nl-NL&P=&PT=0x30&WUA=7.9.9600.16422>. error 0x80072efe
    2014-03-18 12:04:16:237 1076 1830 Misc WARNING: WinHttp: SendRequestToServerForFileInformation MakeRequest failed. error 0x80072efe
    2014-03-18 12:04:16:237 1076 1830 Misc WARNING: WinHttp: SendRequestToServerForFileInformation failed with 0x80072efe
    2014-03-18 12:04:16:237 1076 1830 Misc WARNING: WinHttp: ShouldFileBeDownloaded failed with 0x80072efe
    Opened in IE11 the URL  HTTPS://sls.update.microsoft.com/SLS/{9482F4B4-E343-43B6-B170-9A65BC822C77}/x64/6.3.9600.0/0?CH=41&L=en-GB;de-DE;nl-NL&P=&PT=0x30&WUA=7.9.9600.16422
    opens a file called environment.cab

  • Weblogic domain creation fails with "The domain location must have write permission."

    Hi
    I am trying to install and setup weblogic in Linux RHEL 5.4
    so I can test webservices . This is what i have done
    WLS Zip Distribution for Oracle WebLogic Server 12.1.1.0 - downloaded & installed.
    Followed the steps in README.
    - extract contents of tar, setup home, run installation-configuration script, setup wls environment
    Step 5:
    Create a new WLS domain and start WLS.  It is recommended that you create domains outside the MW_HOME.
         $ mkdir /home/myhome/mydomain
        $ cd /home/myhome/mydomain
        $ $JAVA_HOME/bin/java $JAVA_OPTIONS -Xmx1024m -XX:MaxPermSize=128m weblogic.Server
    -> returns the below error
    $JAVA_HOME/bin/java $JAVA_OPTIONS -Xmx1024m -XX:MaxPermSize=128m weblogic.Server  -Dweblogic.security.allowCryptoJDefaultJCEVerification=true
    <Jun 25, 2013 3:39:57 PM EDT> <Info> <Security> <BEA-090905> <Disabling CryptoJ JCE Provider self-integrity check for better startup performance. To enable this check, specify -Dweblogic.security.allowCryptoJDefaultJCEVerification=true>
    <Jun 25, 2013 3:39:57 PM EDT> <Info> <Security> <BEA-090906> <Changing the default Random Number Generator in RSA CryptoJ from ECDRBG to FIPS186PRNG. To disable this change, specify -Dweblogic.security.allowCryptoJDefaultPRNG=true>
    <Jun 25, 2013 3:39:58 PM EDT> <Info> <WebLogicServer> <BEA-000377> <Starting WebLogic Server with Java HotSpot(TM) 64-Bit Server VM Version 23.21-b01 from Oracle Corporation.>
    /apps/Informatica/tdwdomain/config not found
    No config.xml was found.
    Would you like the server to create a default configuration and boot? (y/n): y
    <Jun 25, 2013 3:40:03 PM EDT> <Info> <Management> <BEA-140013> </apps/Informatica/tdwdomain/config not found>
    <Jun 25, 2013 3:40:03 PM EDT> <Info> <Security> <BEA-090065> <Getting boot identity from user.>
    Enter username to boot WebLogic server:admin  Enter password to boot WebLogic server:admin123
    For confirmation, please re-enter password required to boot WebLogic server:admin123
    <Jun 25, 2013 3:40:13 PM EDT> <Info> <Management> <BEA-141254> <Generating new domain directory in /apps/Informatica/tdwdomain.>
    <Jun 25, 2013 3:40:17 PM EDT> <Critical> <WebLogicServer> <BEA-000362> <Server failed. Reason:
    There are 1 nested errors:
    weblogic.management.ManagementException: Failure during domain creation
            at weblogic.management.internal.DomainGenerator.generateDefaultDomain(DomainGenerator.java:119)
            at weblogic.management.internal.DomainDirectoryService.start(DomainDirectoryService.java:82)
            at weblogic.t3.srvr.ServerServicesManager.startService(ServerServicesManager.java:461)
            at weblogic.t3.srvr.ServerServicesManager.startInStandbyState(ServerServicesManager.java:166)
            at weblogic.t3.srvr.T3Srvr.initializeStandby(T3Srvr.java:883)
            at weblogic.t3.srvr.T3Srvr.startup(T3Srvr.java:570)
            at weblogic.t3.srvr.T3Srvr.run(T3Srvr.java:469)
            at weblogic.Server.main(Server.java:74)
    Caused by: com.oracle.cie.domain.script.ScriptException: The domain location must have write permission.
            at com.oracle.cie.domain.script.ScriptExecutor.writeDomain(ScriptExecutor.java:757)
            at com.oracle.cie.domain.script.ScriptParserClassic$StateMachine.processWrite(ScriptParserClassic.java:573)
            at com.oracle.cie.domain.script.ScriptParserClassic$StateMachine.execute(ScriptParserClassic.java:429)
            at com.oracle.cie.domain.script.ScriptParserClassic.parseAndRun(ScriptParserClassic.java:148)
            at com.oracle.cie.domain.script.ScriptParserClassic.doExecute(ScriptParserClassic.java:110)
            at com.oracle.cie.domain.script.ScriptParser.execute(ScriptParser.java:72)
            at com.oracle.cie.domain.DomainInfoHelper.executeSilentScript(DomainInfoHelper.java:854)
            at com.oracle.cie.domain.DomainInfoHelper.createDefaultDomain(DomainInfoHelper.java:1775)
            at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
            at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:57)
            at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43)
            at java.lang.reflect.Method.invoke(Method.java:601)
            at weblogic.management.internal.CIEDomainGenerator.generateDefaultDomain(CIEDomainGenerator.java:62)
            at weblogic.management.internal.DomainGenerator.generateDefaultDomain(DomainGenerator.java:114)
         <Jun 25, 2013 3:40:17 PM EDT> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to FAILED.>
    <Jun 25, 2013 3:40:17 PM EDT> <Error> <WebLogicServer> <BEA-000383> <A critical service failed. The server will shut itself down.>
    <Jun 25, 2013 3:40:17 PM EDT> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to FORCE_SHUTTING_DOWN.>
    - Any help appreciated.
    Thanks

    hi,
    the binaries available for download are all packaged with 32bit JVM. Please have a look at the link below
    WebLogic Server 12c (12.1.1), WebLogic Server 11g (10.3.6) and Previous Releases
    It also has binaries for linux available. I am quoting from the site verbatim for your reference:
    The following provides links to WebLogic Server 12.1.1 installers with 32-bit JVMs for Windows and
    Linux, the generic installer that can be used on any supported platform, and the zip distribution. The
    generic installer and the zip distribution do not include a JVM/JDK. For instructions on using the
    generic installer, see this document.
    In case you want to use your own latest version of JDK which can be a 32/64 bit version, you need to use the generic installer.
    The error which you are getting is due to permissions. Make sure you have a dedicated user for installing weblogic and the necessary permissions are granted to the user(linux) to the installation directories. May be the script is trying to install java at a particular location on your machine and failing. Hence the above error is displayed.
    Please have a look at the docs, you will find steps for weblogic installation on linux.
    Thanks,
    Souvik.

  • Updates fail with error 1328.   I have re-installed Acrobat XI Pro twice without problems.

    Updates fail with error 1328  I have re-installed XI Pro twice without problems.

    2
    William D. Burstow, CPG, QP
    Consulting Economic Geologist
    Tel:   541.573.1078
    Email:  <mailto:[email protected]> [email protected]

  • A 6 hour installation that should have only taken 30minutes!! Very unhappy customer!!

    I am very upset about a recent purchase I made at your store.  I bought a fridge (an open box item) and it was going to be delivered on Friday, March 28.  The delivery guy (Jake) came at about 10:30 and hauled away our old fridge and brought in the new fridge BUT then the trouble began.  Jake said that the hose part we bought won’t fit the waterline and we need an adapter (looks like the size of a nut or washer – just a little part) I asked him if he had this part on the truck and he said he doesn’t carry parts on the truck and told me I need to go to town (I live 30 miles out of town!) and go to the store and get the part – I was a little confused because he was supposed to be installing the fridge.  I didn’t know much about the fridge so I said ok, what would I need to tell them and he said tell them you need an adapter that is 3/4” to a 1/2”.  So he kinked my waterhose and put a bucket underneath it but it still dripped a little bit so I hurried to town (it is about 11:30 now) to Best Buy to get the adapter and the guy in the appliance area didn’t know what I was talking about so they called Jake and he told the Best Buy employee what I needed and the employee said they don’t carry that part….. so I went to Lowes and they didn’t know what I needed because it didn’t make sense to them that I would need a 3/4” to a 1/2” adapter.  I then went to Menards and talked to the appliance department and then they didn’t know so I was sent to the plumbing department and the lady was very nice there but she also didn’t think it made sense that I needed a 3/4” to a 1/2” adapter because waterlines are usually 1/4”.  So I called up Best Buy while still at Menards and they had Jake (the delivery /installer) talk to the lady at Menards and explain to her what I needed so he told her the same thing – I needed a 3/4” to a 1/2” adapter.  She said that the only thing they would have is 2 options a 3/4” to 1/2” adapter or 1/2” to 1/2” adapter (they both looked like the size that would fit a garden hose!!  I didn’t think that was right but that is what Jake from Best Buy – the delivery /installer guy told the lady at Menards.  So I bought those 2 parts and raced back home because now it was 1:30pm in the afternoon after running around for 2 hours looking for an adapter that Jake said I needed.  I got home and was immediately livid!!  The two parts were what I thought TOO BIG!  Both ends were only 1/4”!  So I called Best Buy again and talked to Mike (I didn’t get a last name) he was very nice and tried to be helpful .  I explained what happened from the beginning (around 10:45am till now 1:30pm) and told him this is outrageous I am missing a whole day of work because of this when I could have been to work by 11:30am if Jake did this correctly.  I told him I can text him photos of everything 1) The end of the water line 2) the end of the fridge 3) both ends held up together 4) each end by a tape measure to show it was only 1/4”.  He said that would be very helpful so he game me his number and I texted the photos to him and I got a call 2 minutes late and he said “umm… I am so sorry for the inconvenience but all you need is an adapter for a female end to a make end and they have those parts on their trucks”, I asked if he was being serious because it was around 2:30pm now and I still don’t have my fridge installed!  Mike said he would call Jake and tell him to get to our house and put the waterline on with the part from his truck.  Mike called back after talking to Jake and he said that Jake was in Crookston, MN for a delivery but would come right back to our house as soon as he was done.  Jake got to our house around 3:30pm and came in and I showed him the parts that I bought that HE told the lady at Menards I needed.  He said he didn’t know what to do.  I told him I talked to Mike at Best Buy and he said you have the part on your truck.  He said he would go look.  He came back in (sure enough) with the part!!!  He connected the waterline to the fridge and it was done (Literally 10 minutes) and left around 4:15pm.  I am so disgusted with the incompetence of your delivery guy/installer, for something that should have taken a total of 1/2 hour or less.  My fridge should have been delivered and installed and I should have been on my way to work by 11:00am to 11:30am.  Instead I spend a whole day running around and make numerous phone calls that were NOT NECESSARY.  Then I tried to call the store and explain about what happened but Nichole – said she was the Home Sales Manager, said there was nothing the store could do and didn’t even acknowledge the incompetence of the installer and she didn’t even attempt to resolve this issue.  I have make attempts to get this matter resolved but have not received ANY responses, I am hoping someone will respond to this message?!?
    Solved!
    Go to Solution.

    Hello magicmel,
    I’m positive you were excited to receive your new refrigerator, and expected the installation to go smoothly. Our installers should be knowledgeable in their field, and able to troubleshoot issues such as you described. It’s truly regrettable that Jake may not have known which part you needed, and sent you on a trip across town to look for a part that was unnecessary.
    After running from store to store only to find that the part needed for your refrigerator was in the installer’s truck, I can imagine how frustrated you would be, as I would be infuriated if I were in your shoes. While I’m glad to hear that Mike was able to get things resolved with just a few pictures, I apologize for any inconvenience this may have caused you.
    I was able to locate your service order and refrigerator purchase, and I am sending you further information in regards to this experience via a private message. You can check your private messages by signing into the forum and clicking the envelope icon in the top right corner of the page.
    Sincerely, 
    Tasha|Social Media Specialist | Best Buy® Corporate
     Private Message

  • For POP-UP, FM needed - that pop-up should have only 'CONITINUE' Button

    For POP-UP,
    I need one  FM
    The  pop-up must  have only 'CONITINUE' Button.
    Could any body can help me  ?

    HI,
      Try this,  TH_POPUP  function module.
    this is the wel suited one
    and here is the ex code, this is used to send the popup message to the users.
    TYPE-POOLS: VRM.
    TABLES:USR02,ADCP,USR21.
    DATA: OPCODE TYPE X VALUE 2.
    DATA: BEGIN OF USR_TABL OCCURS 10.
            INCLUDE STRUCTURE UINFO.
    DATA:   SELECTION TYPE C.
    DATA: END OF USR_TABL.
    Table for F4 Help of User-Id
    DATA: BEGIN OF IUSER OCCURS 0,
             BNAME LIKE USR21-BNAME,
          END OF IUSER.
    End
    Table for List Box
    DATA: BEGIN OF IDEPT OCCURS 0,
             DEPARTMENT LIKE ADCP-DEPARTMENT,
           END OF IDEPT.
    End
    Variables for Drop Down List Box
    DATA: NAME  TYPE VRM_ID,
          LIST  TYPE VRM_VALUES,
          VALUE LIKE LINE OF LIST.
    End
    *DATA: text1 LIKE sm04dic-popupmsg VALUE 'SAP-BASIS TEAM GROWEL :'.
    SELECTION-SCREEN: BEGIN OF BLOCK B1 WITH FRAME TITLE TEXT-001.
    PARAMETERS: CLIENT LIKE UINFO-MANDT DEFAULT SY-MANDT OBLIGATORY.
    SELECT-OPTIONS: USER FOR USR21-BNAME  NO INTERVALS." OBLIGATORY.
    PARAMETERS:  DEPT LIKE ADCP-DEPARTMENT AS LISTBOX VISIBLE LENGTH 40.
    PARAMETERS: TEXT LIKE SM04DIC-POPUPMSG.
    SELECTION-SCREEN SKIP 1.
    PARAMETERS: CH1 AS CHECKBOX DEFAULT 'X'.
    SELECTION-SCREEN: END OF BLOCK B1.
    ---- For F4 Help User name -
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR USER-LOW.
      PERFORM HELP1 USING 'USER'.
    ----Fill Up Internal Table For Drop Down List Box -
    AT SELECTION-SCREEN OUTPUT.
      SELECT DISTINCT DEPARTMENT
                 FROM ADCP
                 INTO CORRESPONDING FIELDS OF TABLE IDEPT.
    ---- Filling up values for the list -
      NAME = 'DEPT'.
      LOOP AT IDEPT.
        VALUE-KEY = IDEPT-DEPARTMENT."sy-tabix.
        value-text = idept-department.
        APPEND VALUE TO LIST.
      ENDLOOP.
    ---- Function Module for List Box -
      CALL FUNCTION 'VRM_SET_VALUES'
        EXPORTING
          ID                    = NAME
          VALUES                = LIST
      EXCEPTIONS
        ID_ILLEGAL_NAME       = 1
        OTHERS                = 2
      IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
      ENDIF.
    AT SELECTION-SCREEN.
      IF USER-LOW EQ 'ALL'.
        REFRESH USER.
        SELECT BNAME FROM USR21 INTO USER-LOW.
          USER-SIGN = 'I'.
          USER-OPTION = 'EQ'.
          APPEND USER.
        ENDSELECT.
      ELSE.
        IF NOT DEPT IS INITIAL.
          REFRESH USER.
          SELECT U~BNAME INTO USER-LOW
                         FROM USR21 AS U INNER JOIN ADCP AS A
                           ON UPERSNUMBER EQ APERSNUMBER
                        WHERE A~DEPARTMENT EQ DEPT.
            USER-SIGN = 'I'.
            USER-OPTION = 'EQ'.
            IF USER-LOW EQ 'SAP*' OR
             USER-LOW EQ 'DDIC' .
              CONTINUE.
            ENDIF.
            APPEND USER.
          ENDSELECT.
        ENDIF.
      ENDIF.
      SORT USER.
      DELETE ADJACENT DUPLICATES FROM USER.
    START-OF-SELECTION.
    SHIFT text1 RIGHT DELETING TRAILING space.
      IF CH1 = 'X'.
        CONCATENATE 'enter here the sender details :' TEXT INTO TEXT SEPARATED
    BY SPACE.
       OVERLAY text WITH text1.
      ENDIF.
      LOOP AT USER.
        CALL FUNCTION 'TH_POPUP'
          EXPORTING
            CLIENT         = SY-MANDT
            USER           = USER-LOW
            MESSAGE        = TEXT
          EXCEPTIONS
            USER_NOT_FOUND = 1.
        IF SY-SUBRC <> 0.
          MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
                 WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
        ENDIF.
      ENDLOOP.
    *&      Form  HELP
          text
         -->P_0093   text
    FORM HELP1  USING   UNAME.
      SELECT * FROM USR21 INTO CORRESPONDING FIELDS OF TABLE IUSER.
      CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
        EXPORTING
      DDIC_STRUCTURE         = ' '
          RETFIELD               = UNAME
      PVALKEY                = ' '
         DYNPPROG               = SY-REPID
         DYNPNR                 = SY-DYNNR
         DYNPROFIELD            = UNAME
      STEPL                  = 0
      WINDOW_TITLE           =
      VALUE                  = ' '
         VALUE_ORG              = 'S'
      MULTIPLE_CHOICE        = ' '
      DISPLAY                = ' '
      CALLBACK_PROGRAM       = ' '
      CALLBACK_FORM          = ' '
      MARK_TAB               =
    IMPORTING
      USER_RESET             =
        TABLES
          VALUE_TAB              = IUSER
      FIELD_TAB              =
      RETURN_TAB             =
      DYNPFLD_MAPPING        =
    EXCEPTIONS
      PARAMETER_ERROR        = 1
      NO_VALUES_FOUND        = 2
      OTHERS                 = 3
      IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
      ENDIF.
    ENDFORM.                    " HELP

  • Logon failed with an Access Database

    Hello,
    I am trying to create a Crystal Reports application that allows the user to view previously created reports (.rpt files).  When I use a .rpt file that has a absolute path for the access database files, it works perfectly.  If I use a .rpt file that uses a relative path (i.e. set the database location in the report to 'same as report') the report prompts me to enter the logon information.  If I cancel those dialogs, I get a logon failed error.
    The application copies the .rpt files and access database files and places them in a specific directory.
    I know, for a fact, that the reports work in another program and in the Crystal Reports designer.  I just don't know why I get this error with this application.
    I am using Crystal Reports XI to create the reports.
    The databases are created using Access 95 (I cannot change this)
    The development computer is Windows 7 64bit
    The IDE is Visual Studio 2008 SP1
    The .net language is C#
    Any help would be greatly appreciated.

    Well, that did allow me to set the location.  I am recieving one error when I do that though.  I believe that it has to do with the fact that the file extension for one of the databases doesn't end with the default .mdb.  I solved this, but then I get an error when trying to load a specific report:
    Failed to load database: 0xce0
    Invalid Join Operation
    Would this be due to the change in the databas name?  I wouldn't think so but I want to be sure.  Other reports work perfectly (of course, the report with the error is the important one!).  And the report that gives the error works in the designer and other applications as well.
    Please let me know if I need to start a new thread on this.

  • Attr change run failed with exception

    hi all,
            My process chain failed at ACR( attr change run) with exception
    "UNCAUGHT EXCEPTION" ...I 've again scheduled that process but it again
    got failed.
      I am not able to undestand what is the problem?
      does anybody have any idea how to resolve this?

    hi arun,
                that was a short dump with the above exception .

  • ODI dataloading Fails With ORA-01729: database link name expected

    Hi All,
              can any one provide me the solution for this error..
    thanks,
    Yogi.

    The correct syntax for denoting a table in a remote database follows:
    username.table_name@ database_name

  • My wife and Iare newbies with iPhone 5s. (Should have waited for the 6.) I have usediTunes for a long time for my iPods, but now we both want to use the iCloud do access different music up there. Any help in doing that? If we can do it, we will be ad

    I'm running iTunes on a PC laptop and ready to move music to an independent hard drive. We want to add more music to it. I have used iTunes for a while for iPods. My wife and I have new iPhone 5S and would like to access the cloud for different types of music, but I will maintain the music in the cloud. (That's my job.) Can 2 iPhones use the same iCloud? We each have different Apple ID's. Thanks.

    Music in the cloud is managed by the separate iTunes Match service ($25/year US). You would sign up to it on the PC, and your music library would be matched with the iTunes Store, and high quality versions of all songs would become available to you on any device also signed into iTunes Match. You should not delete your local copy from the PC, since you should retain a master version of all songs for safety.
    You can use the same iTunes Match service, but you'd see the same music (you say you "would like to access the cloud for different types of music", but I'm not sure what you mean by that).
    Matt

Maybe you are looking for

  • DOUBT IN Z table

    Hi    in my object i want to create Ztable to link old and new custmor account numbers. plz help me out in this problem thanks

  • To solve "an internal error occured in SDK"

    recently,I solve a problem about "an internal error occured in SDk" ,if you have  tried other ways and it is helpless, you can try  add a clock constraints which clocks for  microblaze.

  • Phone power on/off

    My Treo 650 will not let the phone stay on for any length of time. Is there a setting on the phone that will allow the phone to stay on? Also - my phone had another "user" and, even tho I have deleted her name from the Users file on the Hot Sync Mana

  • Discuss - pt vs px vs em

    On another board, someone is suggesting using pt instead of ems for font sizes. I always believed that using pt was primarily for print work, not for the web.... Anyone shed any light on this - or even a link to articles that may be of interet (I did

  • Portal hangs

    Hi, I'm running WLP 4.0SP2 with WLS 6.1 SP2. I noticed sometimes portal server hangs - client's browser keeps waiting and never times out until someone does ctrl+c on the console where WLP is running. Then WLP console spits out a few (or many) lines