Code 10 pci 6034e

Hello,
I have a problem with my LabView and I'm running out of ideas how to fix it. In 2002 I designed a software for data aquisition based on LabView 6.1 using a PCI 6034E card. Since then everything was working fine. A few days ago I had to switch PCs.
I installed LabView 6.1 on the new PC. Afterwards I shut down the system, plugged in the 6034E and reboot the PC. Windows discovered the new hardware succesfully and installed a driver from the LabView Driver CD.
Unfortunately my device manager is telling me that the 6034E is producing a Code 10 error. Until now I have tried to install the newest driver from NI, reinstalling LabView and the drivers multiple times.
The only difference I could encounter betweed the two PCs is that the old PC is operated with Windows XP SP 2 and the new one uses SP 3.
Do you have any ideas what could cause the problem?
Best regards,
Theodor
Solved!
Go to Solution.

Hello Tobias,
thank you for your reply. I already tried installing the DAQmx 7.0 yesterday evening. It worked fine with the PCI 6034E. Unfortunately I couldn't use my programm any more, because some sub vi are incompatible with DAQmx above verson 6.9.3.
However, I managed to solve the problem. There might have been a comflict between the PCI 6034E and the computers video card. I deaktivated the videocards PCI port in Bios and switched to on board graphics. Then I uninstalled all National Instruments software, for a fresh start. After a reboot, video card still disabled, I installed LabView 6.1 and DAQ 6.9.3. After inserting the PCI 6034E now, everything went flawlessly. Windows recognized the card and installed the drivers. According to MAX the card works fine and my programm is also running.
After this I enabled the video card again, via bios. Still everything is working fine. I can't tell you how the video card could have caused the trouble, but one should keep this in mind for the future.
Best regards,
Theodor

Similar Messages

  • Magma-box and DAQ PCI 6034E card

    I had installed a magma-box (64-bit 2 Slot Series) on my laptop. And I installed NI-DAQ 7.1. Than I had plug the PCI-6034E card in the magma-box. My laptop identify the PCI-6034E daq card in the Device Manager; but with a yellow exclamation point and give the Error code 10 (Cannot start the device). The same used with the PCI-6377 card.
    I have tried with the cards in the differend slots.

    Hey Wim,
    I am not sure what a magma-box is. I have searched all over google and I haven't been able to find one. This brings up my next question of how you are installing a PCI-6034E and PCI-6377 on the laptop. National Instruments driver does not support this and I am pretty sure the DMA on the devices wouldn't work as well. The main difference between the PCMCIA devices National Instruments sell and the PCI devices is the DMA channels. If you need to use a laptop I would recommend purchasing the DAQCards or DAQPads that can connect to USB, Firewire, or PCMCIA slots. These devices are supported on laptops. The PCI devices are designed to work on desktop computers with standard PCI busses that allow for DMA channels and ISA based interrupts.
    I hope
    this helps out.
    Joshua P.
    Application Engineering
    National Instruments

  • Implementing a Lock In Amplifier using a PCI-6034E DAQ card

    I am looking for a lock-in amplifier and have read about the Lock-in Amplifier kit provided by NI. I am wonder in is it possible to implement a solution with a PCI-6034E DAQ card instead of the 4472? And if so what would be the limitions of using the 6034 for this application?

    The requirements for the Lock In Amplifier are contained within the document linked bellow. The S series can be used with the Lock In Amplifier but not the E-series.
    http://ae.natinst.com/operations/ae/public.nsf/fca7838c4500dc10862567a100753500/ebaadbd271adfec586256c86007b63f9?OpenDocument
    Regards
    Jon Bowers
    Applications Engineer
    NIUK

  • Calculate uncertainty of PCI-6034E

    Hallo, I am trying to calculate the overall uncertainty of DAQ System, which has a PCI-6034E board and an SCXI-1102B. I know about the accuracy calculator and I am trying to check my results using this tool.
    I use K thermocouples in a temperature range 30-90℃ in an ambient temperature of about 30℃, which corresponds to a input signal range 1,203mV-3,682mV.
    The calculation formula is: Absolute Accuracy = +/-[(Input Voltage x % of Reading)+ Offset +System Noise +Temperature Drift]
    At first I set to the accuracy calculator: DAQ device to PCI-6034E and SCXI module to none. Then I set for example 0.001203V and Average of 100 readings.The result is the following:
    According to the E Series User Manual (page 38 gain+resolution PCI-6034E) Absolute Accuracy=0,001203*0,0588/100+ (28,9 +2,75)*10^-6=0,03235mV
    which the same with the accuracy calculator.
    I I set to the accuracy calculator: DAQ device to PCI-6034E and SCXI module SCXI-1102B, then i do not get the same results about the absolute accuracy of the DAQ device.
    Accuracy Calculator:
    Me: DAQ Absolute Accuracy=0,1203*0,0588/100+ (100 +5,04)*10^-6=0,175mV which I a very large number. I assume that the input value is 0,1203 because the gain of the scxi 1120b is 100.
    What I am doing wrong?
    Furthermore, I cannot find detailed specification about scxi-1102b in the user manual (Offset in Single Point and in average of 100 readings).
    Thank you very much,
    Giorgos P.
    Solved!
    Go to Solution.

    Hello Ginos,
    I went over your calculations and you have calculated the accuracy correctly. The DAQ absolute accuracy at .5 to -.5 is .175mV but they have converted this value so that it has meaning to the orginal signal. The original signal acquired by the SCXI-1102B was multiplied by a gain of 100. After this gain, the signal is sent to the DAQ card to be digitized into your computer.
    In order to relate this digitized signal accuracy to the original signal, they divided it by the gain given by the SCXI-1120B module. This is why there is a factor of a 100 difference between the two.
    Jim St
    National Instruments
    RF Product Support Engineer

  • Thermistor wiring in cb-68lp with PCI 6034E

    I have a CB-68LP pinout board with a PCI 6034E card on a computer with XP and LabVIEW 7.0.  I have been using type K thermocouples to collect temperatures in a lab and have had no problems thanks to previous help.  I am now going to be moving my temperature collection out doors where I will need to run ~1000 ft of wire to reach my destination.  I want to switch from thermocouples to thermistors to save money on wiring.  I have done a little research on thermistors and there are still unanswered questions.  I know thermocouples connect differentially but I could not find information about how thermistors connect?  Since it is just measuring a change in resistance my guess was that it is single ended but I want to make sure.  That is the main question, if anyone has suggestions on current excitation values or possible problems that I might expect that would be great also.  Thanks

    Gorman,
    With NI-DAQmx and Measurement Automation Explorer there is actually a feature called connection diagram which will let you select your connection block and tell you exactly which pins you need to connect your sensor to, whether it is a thermistor or a thermocouple.  You can actually set up a thermistor measurement in Measurement and Automation Explorer for current excitation and voltage excitation seperately.
    For example, I created a current excitation thermistor task in Measurement and Automation Explorer running into ai0 (channel 0) and I clicked on the connection diagram tab at the bottom.  Here is the diagram that I got.
    As you can see, you just need to connect to pins 68 and 34. 
    There is also an example program that you can download, which is in LabVIEW.  Here it is.
    Hope all this helps.
    Regards,
    Message Edited by Raajit L on 10-12-2007 06:05 PM
    Raajit L
    National Instruments
    Attachments:
    thermistor_current.png ‏23 KB

  • Combining PCI-6034E with NI-4350

    I have an application requiring the measurement of 12 4-20mA signals and 8 K-type thermocouples.
    My proposal is to use a PC fitted with a PCI-6034E DAQ through a TBX-68 I/O Connector Block for the current signals, and an NI-4351 Temperature Logger through a TBX-68T Connector Block for the thermocouples. Can anyone foresee any problems with such a set-up? Are there any unforeseen difficulties I should be aware of?
    Control will be by LabVIEW.
    I am spending someone else's money from a very tight budget, so I need to keep the cost down and to get it right the first time.
    The original proposal was to use FieldPOINT gear but its temperature logging is a little slow.
    Thanks in advance for your help.

    Hi Ledge,
    How fast do you want the temperature logging to be that FP is too slow?
    Ben
    [email protected]
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • DAQ PCI-6034E for RTX

    Hi,
    Does anyone know how to read data from the  DAQ PCI-6034E board using RTX ?
    thanks

    Hi,
    I think you have to write a register level driver for the PCI-6034E to use RTX... No National Instruments driver exists for E series and RTX.
    Below is a link to help you ....
    http://digital.ni.com/manuals.nsf/websearch/5978CE4A83119E50862566FA0075F424?OpenDocument&node=13210...
    Personnally, I recommend you to use new M series (similar to E series) because they are supported under RTX via NI-DAQmx Base 2.0.
    Regards,
    David D.
    Application Engtineer - NI France

  • PCI-6024E or PCI-6034E

    Can I use pci-6024e or pci-6034e card to get 0.5mV~50mV
    data precision 0.01mV.Can is it work?

    Hi Anon...
    I do not know the specs of those cards off hand, but I will explain how to figure it out yourself.
    Find the range of the board that you will use for the measurement.
    Divide the max value by 2^n where n=number of bits of resolution.
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • Is there a known conflect between PCI 6034E and 7344

    I just installed a new PCI 6034E and now the DAC on my PC 7344 motion board seems to be putting out non-linear voltages from my position encoder. Does anyone know why?

    LA 75,
    Thanks for your answe,r here are mine.
    1. The 7344 worked fine until I stuck the PCI 6034E in it. I have an update for you on the problem which I learned after more testing. The quaditure count on the encoder is 16384
    I only need to measure -20 to 90 degree angles in my application. When I set up my DAQ channel (using a PCI 6025E which I still have in place) I calibrated based on +10 volts
    out of the 7344 DAC channel (axis 3) = 90 degrees an 0 volts = 0 degrees. What's really happening is that the DAC output is now 12.4 volts and its saturating the DAQ input
    channel. If I recalibrate with 0 volts = 45 degrees I can work around the problem...the thing is I don't know what caused this and what other safety implications there might be.
    2. The new board (PCI 6034E) is in the last slot and the 7344 is in the first slot...in between is an ethernet card and the PCI 6025E.
    3. I do not have another PC to test this thing in.
    Jim Fee

  • NI PCI-6034E是否可以采集交流0-5V电压信号

    NI PCI-6034E是否可以采集交流0-5V电压信号,采集后的信号怎样才能获得这个信号,是在软件里面要进行某些设置还是其他什么,另外,用68针非屏蔽接线盒在接线的时候采用差分输入接线,怎么接线的/

    NI PCI-6034E是否可以采集交流0-5V电压信号, Yes
    采集后的信号怎样才能获得这个信号, 是在软件里面要进行某些设置还是其他什么,Through DAQMX in LabVIEW or MAX (Measurement & automation explorer)
    另外,用68针非屏蔽接线盒在接线的时候采用差分输入接线,怎么接线的/  When you say 差分输入, you mean differential measurement, right?  I took a quick look at the manual, the device seems to have a common ground for all analog input
    Kudos and Accepted as Solution are welcome!

  • Device ID number for the PCI-6034E

    What is the device ID number for the PCI-6034E?

    Wayne,
    squeen is correct... the device ID for the PCI-6034 is 0x2CA0
    Dan
    Message Edited by Mcdan on 07-12-2005 01:21 PM

  • Acoustic Time of Flight Calculation with PCI-6034E

    I'm trying to measure the amount of time sound takes to travel through a specific medium with Labview 7 and a PCI-6034E DAQ card. So far, I have the speaker connected to ctr0 and that generates the specific frequency that I want. I want to have the program run the sound and then stop it when I hit a button and then measure the amount of time it takes for the microphone to stop receiving the sound. I don't know how to use the analog input (from the microphone) to trigger some sort of timing device. This timing needs to be as accurate as possible. Thanks for your help.

    I don't know what your fluid is, but I just looked up info on sonar which gives a propagation speed of nearly 1 mile/sec in water. That leaves you with <30 microseconds to traverse your 40 mm container.
    Soooo...., I don't know if you can do your measurement with a 6034E. It's max sampling rate is 200 kHz or 5 microseconds/sample. I doubt that'll be enough resolution to reliably distinguish the varations in time-of-flight that you're after.
    If you're stuck with the 6034E, you'll probably need to perform the measurement with one of its counters and then build a little external interface circuitry. There's several ways, here's one:
    Use ctr0 to generate a single high pulse with a duration longer than your worst case time-of-flight. Use ctr0_out to switch on a transistor that allows your ultrasonic stimulus signal to get through to the speaker. ctr0_out should also be NAND'ed with a signal to be desribed in the next paragraph.
    Run the mike signal into a comparator and let the comparator's output drive a latch. The idea is to produce a digital rising edge at the instant the mike first receives a significant signal, i.e., your stimulus. NAND this signal with ctr0_out and pass the result into ctr1_gate.
    Configure ctr1 for event counting, set to count 'while gate is high'. (Under the newer DAQmx, the terminology is 'pause trigger.') Software select its source to be the internal 20 MHz timebase.
    How it works:
    Start ctr1 first, then ctr0. On the rising edge of ctr0's pulse, ctr1 will increment once every 50 nanoseconds (i.e., counting cycles of the 20 MHz internal clock). ctr1 will stop incrementing when the mike detects a sound level above the threshold you've set up in your circuit, driving the . The value of ctr1 multiplied by 50 nanoseconds is your time-of flight.
    Then, software reset your counters, hardware reset the latch, change or manipulate your fluid, and try again.
    There's very likely a simpler solution. Anyone?
    -Kevin P.

  • Windows 7 - Pci-to-Pci Bridge (Error: Code 10) - PCI Video Card

    Before I state my issues I will list what I'm running and what I'm trying to accomplish.
    I'm running Windows 7 Enterprise 64-bit edition, not the Beta or RC. I have 3 video cards in my possession (listed below).
    - (PCIe) Evga GTX260
    - (PCI) Evga 9400GT
    - (PCI) Evga Fx5500
    Out of those 3 cards I only use the GTX260 and the 9400GT. I had to 'retire' the Fx5500 because the latest WHQL (certified) drivers only provide support as far down as the "6 series" Nvidia cards. Unfortunately the Fx5500 is a "5 series" and falls below that line. I have already tried to use the GTX260 and Fx5500 in previous versions of Windows (XP and Vista), but there is no way to download and install two separate drivers for two of the same make of video card - you'll get nothing but errors. There is the option of going to a place like guru3d.com and downloading a custom supported driver that covers both the GTX260 and Fx5500, but the drivers are not certified and lack support. Therefore, I purchased and now use the 9400GT which is covered under the drivers for the GTX260 and eliminates the need for messing around with custom drivers. Also, the 9400GT has a better graphics processor and more memory than the Fx5500, so it was time to upgrade anyway.
    Now that you have some background info here is my issue Whenever I install the 9400GT I get a second 'pci-to-pci bridge' entry (the other entry has no errors) that shows up under 'System Devices' in the Device Manager. The second pci-to-pci bridge entry has a yellow triangle with an exclamation mark on it that refers to a problem. When you check the properties of this device it more or less says that Windows has detected a problem (Error Code 10). The GTX260 still works and even shows up under the 'Display Adapters' as a GTX260, but no entry for the 9400GT exists. I have tried the 9400GT in both PCI slots and each time it does the same thing. If I pull out the GTX260 and ONLY run the 9400GT, I still get the pci-to-pci bridge issue, BUT I do get a picture and can boot into Windows 7 without a hitch. When I do this there is still nothing listed under the 'Display Adapters' as a 9400GT or even a VGA compatible device.
    After messing around with this for 10 hours (yes, I said 10 hours) I decided to dig out my retired PCI video card (the Fx5500). When I installed this card I had no 2nd pci-to-pci bridge entry appear under 'System Devices', and the one that was listed had no yellow triangle or error codes. I then checked under 'Display Adapters' and Windows 7 had recognized it as a VGA compatible device and was asking for drivers.
    I have now concluded that there is definitely no issue with the motherboard or any of my hardware (including video cards). At first EVGA Support and I had suspected that the motherboard may be bad because of all of the pre-diagnostic steps I had taken during my 10 hour ordeal. I'm not going to list everything I did because it would literally take 3 hours to type it all in. Just believe me when I say that I have tried most things including but not limited to the latest bios updates (flashed 4 times and completely reset to ensure accuracy), custom IRQ management, entire OS re-installation X2, multiple/latest chipset drivers installed, multiple/latest video drivers installed, memtest testing, complete hardware teardown and re-build (adding one device at a time), and MUCH more. The only thing I did not try was installing a different OS other than Windows 7 64-bit to see if I could replicate the issue. This is a waste of time though because lets say that I install Windows XP Pro and the 9400GT doesn't have this issue... Well, that's great, but who gives a damn about XP Pro when I have been using it for the last 9 years and when I have a full version of Windows 7 that I want to use? I'm certainly not going to run XP Pro over Windows 7 just to use this PCI video card. Second, if I install XP Pro and it still gives me the same pci-to-pci bridge error then again, I've only wasted more time because if its not going to work in either OS then Im sure as hell not going to leave XP Pro installed when I can use Windows 7.
    Thanks,
    piyush

    Maybe stupid question now but has your posting anything to do with Toshiba and Toshiba notebooks?

  • Give digital code to pci 6251

    I want to test dac's performance in NI 6251 (PCI bus) .How  can I give the digital code to dac input?
    PS I have used DaQmx software but I can programme only voltage value. I need test the analog output corresponding
    to a particular digital code

    You can improve performance by using either unscaled or raw
    writes.  By changing the polymorphic type of the DAQmx Write VI,
    you can access these lower-level write functions.

  • Need device code for PCI-6013

    Help!
    Where can I get the device code of a PCI-6013 card?
    Thanks
    Mike

    Mike,
    What programming environment are you using? If LabVIEW, what version? Also, what version of the DAQ drivers are you using?
    Thanks,
    David
    David H.
    Systems Engineer
    National Instruments

Maybe you are looking for

  • Problem installing SolMan 4.0

    Hi to everyone! I'm having a problem in the step 16 (Perform post-load activities) of the Solution Manager 4.0 installation on Windows 2003 and Oracle 10.0.2. The Windows displays an error message "The procedure entry point longjmp could not be locat

  • Acrobat Forms Cache and Emailing

    I have a technical question regarding using the Auto-Complete function on Acrobat.  I fill in mutiple forms with mutilple pages prior to emailing them to clients.  The information being filled in is personal information and should not be accessed by

  • Re-download app store purchase. Installed button is all that's there.

    Hi, I just purchased OS X Lion using the App Store. The download failed after some time and now I'm stuck without the download and no way to download it again. I visited the 'Purchased' page on the App Store but that does NOT have a link to force dow

  • Hi, i cannot open PDF files.  I recently downloaded a sample of Adobe Pro, but that has now expired

    Hi, i cannot open PDF files.  I recently downloaded a sample of Adobe Pro, but that has now expired and my PC wants a code input to enable me to open adobe files. I do not wish to purchase Adobe Pro as it is too expensive. please help, being unable t

  • Last payment not paid.

    My last payment was not paid due to a change in credit card. When i load up Photoshop it tell me it will shut down in about 20 days and gives me a link to my account. i have changed the credit card on my account but nothing has happened. It says next