Como simular la tarjeta DAQ USB 6008

Me gustaría saber si se puede simular la tarjeta de adquisición de datos para hacer pruebas simuladas de protección, de antemano muchas gracias.

No es posible la simulación de la USB 6008. La lista completa de los dispositivos que no pueden ser simuladas se puede encontrar aquí: What are NI-DAQmx Simulated Devices and How Do I Use Them? 
Tim W.
Applications Engineering
National Instruments
http://www.ni.com/support 

Similar Messages

  • C# apply to DAQ USB-6008

    i have a problem about DAQ USB-6008 of application in c#, i would like to use c# code to program the window that can display the temperature c/f and wave graphic celsius versus time ,which is used in thermal couple,its my first time to use DAQ system ,i have no idea what to start , is there anying information about it?

    USB-6008 沒有冷點補償,所以無法量測溫度。
    建議USB-9211
    http://sine.ni.com/nips/cds/view/p/lang/en/nid/14165
    C:\Documents and Settings\All Users\Documents\National Instruments\NI-DAQ\Examples

  • Thermocoup​le DAQ USB 6008

    Hello
    I am novice of LABVIEW and DAQ system. If now i am going to use thermocouple, will it be suitable for me to use USB 6008 to acquire and analyze signal. USB 6008 has no filters inside. Using labview, will the noise be filtered out by LABVIEW itself using FILTER vi?
    if signals are going to be analyzed continuously( it will measure ambient temperature with sudden hot air is blown against thermocouple intermittently), how would u recommend me? how can i take only signals with hot air and disregard the ambient temperature( as differentiate the hot air from ambient air).

    Hi to all,
    I don't understand very well whats mean this that says johnsold:
    "The USB-6008 has 12 bit resolution (differential) and the most sensitive range is +/-1 V. This means that the resolution is about 0.5 mV."
    could someone explain to me please?
    I am trying to read sensor Lm 35, through the USB6008 and get a signal with noise near .005 V. In fact when I read any signal I have this noise level, can you advise me?
    Thanks, greetings.

  • Will USB-6008 DAQ be able to power and record voltage for UMS T5 tensiometer at the same time?

    I would like to use my NI USB-6008 to provide power to my UMS T5 tensiometer  (http://www.ums-muc.de/en/products/tensiometer/t5.html) as well as take readings from it, but I don't know if this is possible to do properly. The supply voltage for the instrument can be as low as 5V, which I can easily get from the dedicated +5V channel. I am able to power the instrument and connect it to an analog input on the 6008 and measure a voltage in differential mode. However, while reading the support literature for the instrument, I find the following:
    "Potential data acquisition pitfalls: Because the pressure transducer is configured in a Wheatstone full bridge, the input voltage and signal mV output cannot be connected to the same reference (ground). Hence, the signal mV output can only be measured using a differential voltage measurement. Therefore, do not attempt to make a single-ended measurement of the pressure transducer mV output."  (http://www.decagon.com/assets/Uploads/MeasuringUMSTensiometerswithnon-UMSControlandDataAcquisitionSystems.pdf)
    My understanding is that the 6008 can take a differential measurement if I attach the signal "+" and signal "-" to the positive and negative analog input terminals. However, it seems that all of the Ground ports on the 6008 are grounded to the same reference, which would make my voltage measurement invalid according to the paragraph above. So my real questions is: if I attempt to record the voltage using one of the analog inputs on the 6008 in this way, is the measurement valid? Or do I need to find a separate power supply with a different reference ground to ensure that the measurement is accurate?

    The specification sheet for that device is very poor. The manual is not much better. Companies which want to sell scientific equipment should publish decent data sheets or get out of business.
    In section 3.4.3 General requirements the device is described as a "non-amplified bridge circuit."  This information along with the bridge impedance should be in the specifications because it is essential to applying the device under any circumstances other than the nominal behavior at 10.6 V.
    The answer to your question is this:
    You can use it with the USB-6008.  The 5 V power supply will result in output voltages slightly less than half (5/10.6) the voltages specified under nominal conditions. You can use the differential input mode on the USB-6008.  The absolute input voltages will be about 2.5 V with the 5 V supply. That voltage is within the working range of the device. The differences will probably be less than 100 mV. The resolution of the USB-6008 on the +/-1 V range is about 0.5 mV so your pressure resolution will be around 1 % of full scale. The input impedance and termination voltage of the USB-6008 will introduce some errors.  These may be on the order of 5-10%. I cannot predict much better without the missing bridge impedance specification.  Those errors should be systematic and relatively constant. A calibration of the whole system - sensor and DAQ device together should allow you to compensate for much of that error.
    Lynn

  • Como controlar velocidad con un PID con USB 6008 ?????

    Buenas tardes.
    Acabo de adquirir mi placa USB 6008 y estoy comenzando a trabajar para poder controlar la velocidad de un motor trifásico asincrónico estandar.
    Para esto contruí con un microcontrolador y una etapa de potencia la parte del variador. Y logré con esto que mi variador reciba una entrada de 0 a 5 Vcc y con ello varía la Frecuenci-Tensión de salida. Es decir solo necesito entregarle 0 a 5 V para que este actúe sobre todo el rango de frecuencias de salida.
    También contruí una placa de aislación galvánica que separa absolutamente la salida analógica de mi USB 6008 con la placa del variador que construí, como para separar las masas y la señal y evitar inconvenientes en mi Notebook y placa de adquisición.
    El feedback de velociodad lo hago con un sensor óptico y un disco dentado acoplado al eje del motor que me puede dar según mi necesidad 1 , 2 , 4 , 6 , 8 ó 10  pulsos por vuelta de acuedo a como lo ubique ó a mi necesidad.
    Entiendo que la placa USB 6008 no es la mejor alternativa para trabajar a tiempo real, y mi sistema operativo ( windows vista x64) tampoco. Pero mi sistema es bastante inercial desde el punto de vista mecánico, y también lo es por la placa del variador que no tiene una respuesta instantanea por cuestiones de constantes de tiempo que le di al firmware del micro. Es decir que no necesito velocidad en el sistema ni en el VI que necesito desarrollar.
    Resumiendo, necesito entrar a mi placa USB 6008 con pulsos ( los que se necesiten por cada vuelta del motor) y luego salir por una salida analógica ( de 0 a 5 V) con la información de velocidad que va al variador.
    Tengo a mi disposición Labview 8.5 con el Control design & simulation que tiene incluidos subVI con PID's listos para usar.
    En medio de este sitema, necesito generar un VI con el que pueda dar una referencia de velocidad desde un potenciómetro virtual en mi panel frontal, y que el PID en el programa de Labview corrija errores de velocidad por alguna pequeña variación de la carga, etc.
    La verdad que estuve probando hacer un VI con un PID bastante simple, pero a la hora de simularlo, fuí modificando los parámetros del PID y no vi que se haga "mas inercial"cuando aumento el tiempo integral. Tambien probé salir de mi placa con una tensión analógica, y dar una referencia con un potenciómetro como para probar si el PID se hace mas "rápido ó lento" al modificar las variables Integrales ó derivativas y no vi variaciones en la respuesta.
    Por eso es que pido ayuda en este foro, ya que probablemente alguien ya hizo alguna prueba, o me puede indicar como arrancar con este tema.
    Este proyecto es solo con fines académicos, para mi tesis de Ing. Electrónica. Por ello el motor no tiene carga, solo el disco dentado y el sensor óptico, solo lo puedo frenar un poco para ver la corrección.
    He comprobado que saliendo de mi placa 6008 con una señal analógica, pasandola por una placa que simula un retardo en el tiempo de esta señal, y reingresandola a una entrada de mi placa 6008 para luego con un VI generar el PID y tratar de que esta señal de entrada a la placa 6008 sea igual a la de setpoint, solo logro oscilaciones con una media que está lejos del valor del setpoint.
    Espero que alguien me pueda indicar como empezar, ó darme algún ejemplo que me pueda ayudar, ya que no soy experto el Labview, solo acabo de empezar a usarlo.
    Reitero que no necesito velocidad ya que mi sistema es lento, y solo debo variar mi salida analógica con velocidades muy bajas. Es decir no necesito respuesta inmediata.
    La idea es hacer una demostración del uso de un PID en un sistema real con Labview.
    Saludos...!!!!

    Hola.
          Sigue unos links para su consulta.
         http://forums.ni.com/ni/board/message?board.id=240​&message.id=8027&requireLogin=False
         http://zone.ni.com/devzone/cda/tut/p/id/3782
         http://zone.ni.com/devzone/cda/tut/p/id/6951
    Saludos
    Diogo.
    Diogo Aparecido
    Engenheiro de Aplicação
    National Instruments Brasil

  • Laser operation with a USB 6008 DAQ

    I'm wondering how I go about using the USB 6008 DAQ in conjuction with labView to turn on and off ths laser: 
    http://www.maplin.co.uk/p/1mw-3v-red-laser-module-le07h
    The laser must be turned on using 3V which isn't possible with this DAQ. I was thinking of usinga BC 109 transistor, then have the laser connected to an external power supply which is supplying 3V to the laser. then have the laser connected to the collector of the transistor.
    I set this up and it didn't exactly work out as the laser was drawing to high a current and not working correctly.
    Can anyone help me?

    OK. The problem is that you need to supply about 30 mA to the laser to get it to work. The digital outputs of the USB-9008 are limited to 8.5 mA or less. Furthermore, a laser diode is a current operated device. If you apply a fixed voltage the current will vary depending on the exact doping used when the device was manufactured and on it instantaneous temperature. The curretn rises exponentially with voltage as in any diode. The link you posted does not have any real data about the electrical characteristics of that diode.
    Typically a current regulating circuit is used to drive laser diodes.  The simplest circuit is a resistor in series with the diode connected to a power supply with a voltage higher than 3 V. The value of the resistor depends on the power supply voltage, the voltage drop across thes witching transistor, and how much current you want to run through the diode. If you have applied 12 V to that laser from a source which can provide substantial current (>50 mA), you have probably destroyed it.
    Lynn

  • Usb 6008 daq spi lcd server client

    Hi.
    I'm new to the labview.ich have a project and comes to data acquisition and remote monitoring
    detaille:
    2 computer are labview installed on both and connected to wifi / internet.
    the server computer connected with ni usb 6008 and it pt100 temperature sensor
    it should also include the measurement data display on an LCD
    it should be the client computer also read out the measured values
    has anyone an idea how could you start?., I will be very grateful

    This sounds like a pretty big task for someone new to LabVIEW.
    First get the DAQ working on the server PC.  There are tons of examples that ship with LabVIEW for taking DAQ, go to Help >> Find Examples.
    Getting the information to your other PC can be done many different ways, but maybe the easiest is to just use a Web Server to control the front panel.
    http://zone.ni.com/reference/en-XX/help/371361H-01/lvconcepts/viewing_fp_remote/
    Also you could remote into this PC using remote contol software and remote desktop.
    As for displaying data on an LCD.  A relativly simple solution is to use an Arduino UNO, the LIFA toolkit and an LCD connected to it.  It is a little bit if a round about solution but the LIFA toolkit comes with code to output to LCDs connected and it is relatively easy to use.
    EDIT:  LIFA https://decibel.ni.com/content/groups/labview-interface-for-arduino
    Unofficial Forum Rules and Guidelines - Hooovahh - LabVIEW Overlord
    If 10 out of 10 experts in any field say something is bad, you should probably take their opinion seriously.

  • How can I make LabView 6.1to detect DAQ NI-USB 6008

    I have a LabView version 6.1, recently I bought a new DAQ model NI-USB 6008, I could not use it with my Labview version. Please, how can I adapt my DAQ for version 6.1 or update my LabView to detect my DAQ? Please advise me to a free applicable solutions. Thanks very much

    The USB 6008 requires DAQmx which requires LabVIEW 7.0 or greater. The upgrade to 7.x (or the just released 8.0) is not free. The only other solution I've heard of is to use the Call Library Function Node to make your own calls to the DAQmx dll. This would not be for the faint of heart or anyone wishing to come up with a quick solution.

  • Ayuda con proyecto fuzzy y tarjeta DAQ 6008

    Hola buenas noches,
    Les escribo porque estoy realizando un proyecto basado en un sistema de control de temperatura basado en lógica difusa, así que me decidí por usar Labview y la tarjeta DAQ 6008 que tenia a la mano, modifiqué satisfactoriamente un ejemplo que trae el toolkit, cuando lo simulo me funciona perfecto, el sistema responde muy bien, pero cuando intento conectarle el sensor de temperatura y la señal de salida de control, el sistema falla totalmente, no se que parte estoy haciendo mal, pero solo reemplazo conxiones y nada, la tarjeta está buena, la probé aparte y funciona bn, solo cuando laintegro al sistema fuzzy no funciona el proceso.
    adjunto archivo .zip con la simulación funcionando bien y con el esquema del problema, si alguien es tan amable de colaborarme.
    Muchas gracias
    Adjuntos:
    Temp.zip ‏549 KB

    Que tal.
    Despues de revisar los dos codigos encontre los siguiente:  en el codigo simulado se presenta la siguiente situacion
    Sin embargo cuando trabajas con la DAQ haces lo siguiente.
    pienso que eso puede ser el error. Edite tu codigo pero debes verificarlo para ver si es lo que necesitas o sigue presentando errores. 
    Saludos.
    Jonathan Cruz
    CHALLENGER
    K U D O S __ B I E N V E N I D O S
    Adjuntos:
    Control Fuzzy Temperatura PG test tarjeta 6008.vi ‏329 KB

  • NI-DAQ for USB-6008, LV 2012

    Hello, I have a NI USB-6008 for which I want to create a VI with Labview 2012 for logging one channel at 0-2V from a current shunt. In the our previous version of Labview 2011 I was experimenting with DAQ Assistant which made the job easy, but in LV 2012 this doesn't seem to exist.
    I was reading help files and I should be able to use NI-DAQmx but I can't seem to be able to find it. In NI Max I can see NI-DAQmx is there and can run  NI-DAQmx test panels on the USB-6008, but in LV 2012 I go to blank VI, block diagram, and I'm stuck. Any help will be greatly appreciated.
    LV 2012
    Windows XP
    NI USB-6008

    Hi there,
    Can you check if you have DAQmx functions in Measurement I/O > NI-DAQmx in the function palette?
    If no, did you re-install the DAQmx device driver together with LabVIEW 2012?
    And what is your DAQmx version you're currently using?
    - Ee Lim -
    See that button on the left side of this post...
    If you feel my post is helpful, all you need is just (at most) 2 seconds to click that button, to show your appreciation. Thank you~~

  • Controling heating/cooling element with labview and usb 6008 DAQ card

    Greetings All
    I'm looking for a heating/cooling type of element that I can control with labview and my usb-6008 card. Heating/Cooling will just be for clean water and the temperture range will be from 0 C to 100 degree C.
    Thanks
    The heating and cooling elements can be seperate products. Any recommendations

    A simple kettle element will of course be sufficient for upto 100°C
    To get the temperature down you need a cooling system, what springs readily to mind of course is a refrigerator.
    Just a note of warning, water and electricity are dangerous bed fellows.
    On that note perhaps one of those vortex air units would be safer - they blow hot in one direction and cold in the other, nominally to 100°C
    see: -
    http://www.airtxinternational.com/how_vortex_tubes_work.php

  • PWM por USB-6008 en Labview 7.1

    Saludos a todos, mi problema es que necesito controlar 5 servos de un brazo robot que ya tengo armado y quiero sacar las señales PWM por medio de la USB-6008, solo dispongo de Lavbiew 7.1, ya genere las señales pero no tengo la menor idea de como enviarlos, por favor si tienen algun ejemplo les agradecería que me lo colocaran como imágen pues no puedo ver los ejemplos de versiones mas recientes de Labview, gracias por su pronta respuesta ya que debo entregar el proyecto antes del 15 de noviembre  y es requisito para mi graduación de Ingeniería Electrónica.

    Hola Coky aquí el problema es en sí que estás trabajando fuera de las especificaciones de la tarjeta 6008. Esta no cuenta con un reloj interno por software por lo que tanto las salidas y entradas digitales como las analógicas están controladas por software. El control por software lo mas que te puede dar es un loop de 1ms, por lo que en el periodo de 1ms que quieres madamas podrías actualizar la señal 1 vez. La velocidad que puedes alcanzar por software es de 1khz.
    Mas que utilizar dos tarjetas 6008, te recomendaría utilizar una tarjeta más completa por ejemplo una que utilice contadores, o una tarjeta mas rápida como la NI USB 6211, que además cuenta con contadores y te permite trabajar a 250kS/s, y el timing interno es por hardware.
    Otra opción es que a través de tus salidas digitales controles componentes como un 555 y que con este controles tu servo.
    Saludos
     

  • Com use I use quick mi usb-6008

    Hola a todos, estaba trabajando con mi usb-6008 sin problema alguno, pero no estoy seguro si se genero un corto y enseguida la usb 6008 ya no quizo trabajar, ahora ya ni siquiera enciende el led, reinicie mi pc, despues por medio del Ni-max trate de ultilizar la opcion de self-test para ver en que estatus estaba mi usb, pero no esta habilitada la opcion cuando vulevo a conectar el usb, mi duda es como saber si el usb-6008  esta o no quemado, por su ayuda GRACIAS

    Hola Mejillas:
    Te sigas los siguientes pasos, para descartar cualquier opción:
    Reinstala/Repara NI-DAQmx 
    Conecta tu dispositivo al computador
    Revisa que el dispositivo USB-6008 se encuentre con los drivers de Windows correctamente instalados en el "Device Manager" de Windows
    Considera tener a mano otro cable USB A to USB B, puede ser que esté fallando éste
    ve a MAX y asegurate que aparezca un ícono de color verde que diga USB 6008 debajo de la sección "Devices and Interfaces"
    Selecciona Test Panels y luego dentro de esa ventana presiona Start
    Si luego de estos pasos aún está fallando la tarjeta, entonces yo sospecharía que el problema puede ser el hardware
    Aquí tienes un par de link que te pueden servir:
    Getting Started : http://www.ni.com/pdf/manuals/375553a.pdf
    USER GUIDE AND SPECIFICATIONS: http://www.ni.com/pdf/manuals/371303m.pdf
    Saludos
    Klaus F. Breuer
    Field Applications Engineer
    National Instruments Cono Sur
    ¡Los Kudos son gratis y te hacen feliz!

  • ¿Puedo acondicionar una señal generada por un sensor de humeda capacitvo para medirse con un USB 6008?

    ¿Puedo acondicionar una señal generada por un sensor de humedad capacitivo para medirla con una USB 6008?

    Hola;
    La respuesta corta es sí; pero debes agregar acondicionamiento externo.
    Una tarjeta USB 6008 tiene entradas digitales y entradas analógicas de voltaje; por lo que si quieres conectar algún sensor que entregue corriente o una resistencia variable, requieres realizar acondicionamiento externo que te permita la conversión de estas señales a un voltaje; así como filtrarlas y amplificarlas.
    Dependiendo del tipo de salida del sensor capacitivo; puedes tener una señal AC que puedes convertir a una señal de voltaje que puede leer la USB 6008 usando una resistencia. V=IR.
    Si el sensor usa una configuración de puente de capacitancia (similar a la de un puente de wheatstone); entonces tendrías que construir el puente para realizar la compensación adecuada y leer entonces un voltaje.
    Si tienes un diagrama o especificaciones del sensor te podríamos ayudar a determinar que tipo de acondicionamiento necesitas.
    Exito en tu aplicación... 
    Saludos

  • Error -10401 occurred at AI Group Config - in relation to USB-6008

    I'm attempting to run a simple vi that uses AI Aquire Waveforms.vi to input voltage data that I have coming in from the USB-6008 DAQ.  However, when I try running the program, I receive the error:
    Error -10401 occurred at AI Group Config
    Possible reason(s):
    NI-DAQ LV:  The specified device is not a National Instruments product, the driver does not support the device (for example, the driver was released before the device was supported), or the device has not been configured using the Measurement & Automation Explorer.
    And I'm not sure how to fix it.  In MAX, the device seems to be working properly and everyhting seems to work fine in the test panel, so I'm slightly at a loss.  I'm running Labview 7.1, and installed NI-DAQmx 7.5 which came with the USB-6008.

    Never mind.  I'm new to Labview, and didn't realize that I could not use the traditonal Data Aquisition components with the USB-5008 (I didn't even realize that NI-Daqmx was different).

Maybe you are looking for

  • Need the output of a query in given XML format

    I have a table as create table t_cases (case_id number, pros_seq number, case_lname varchar2(100), day_phone number, night_phone number, intl_phone number); where case_id and pros_seq is the compound primary key. The insert script to insert the data

  • Pre-Order games and the GCU

    There seems to be 2 options. Go to a store, print out the ticket, go to the register and pay $5 to hold your copy, or put money down.  Come back and relay on the system to give you the 20% discount. Order online, get the discount right away, pay in f

  • Sax Parser for loading XML file

    We have a requirment by which we need to load huge XMl file in our DB everyday. THe XML file format is like -- <?xml version="1.0" encoding="UTF-8"?> <root> <emp> <ename>aaa</ename> <sal>3000</sal> </emp> <emp> <ename>bbb</ename> <sal>5000</sal> </em

  • Rmi client throws Connection Refused exception

    My Rmi client throws a Connection Refused exception when i try to run it on remote machine (in this case i run it on my virtualbox macine). The virtualbox machine network is in NAT mode (host machine ip should be 10.0.2.2). When rmi client starts get

  • Using "root" in Actionscript 3.0???

    Does anyone know how to get the "root" action to work in 3.0? It used to be (1.0 and 2.0) that using "_root." would go to the root level of the movie (leaving a movie clip) and then you could control the timeline (or target another movie clip), but n