Conversion of alternate unit of measurement

Hi,
System will not allow to enter conversions of unit of measurements in decimal points. But is there any configuration or method, we can force system to accept conversions of unit of measurements in decimal points only? (For example 2.5kg = 1pc, base unit of measurement is 'PC' and alternate unit of measurement is 'KG')
Regards,
Sattuj

Hi,
For the given example of Alternate conversion you can use the following setting :
2.5 Kg = 1 Pc
Put the Values as :
25 Kg = 10 Pc
With this the objective of Decimal is achieved.
Please check the following posts for more info :
[Re: variable order unit]
[Re: Base Unit of Measure]
[Re: Issue in unit of measure]
Hope it helps,
Best regards
Amit Bakshi

Similar Messages

  • Conversion in Alternate Unit of Measure

    Hi All,
    I have a report in which i report data in both base and alternate units of measure, the report has three filelds Material , Quantity (BUOM) and Quantity (AUOM). The problem is for a certain material; say Mat_1, the unit in which it is entered can be Carton or EA, i am using Carton to litre conversion, but my query fails when the material has EA as its unit. Is there a way by which i can convert the unit to litres be it in Cartons or EA???
    Kindly suggest a solution anyone pls pls help
    Thanx in advance
    Regards,

    Hi,
    You can define your own Unit Translation using Tcode RSUOM in such a way that it takes a dynamic unit from each source record with fixed target unit as Litres.
    Refer http://help.sap.com/erp2005_ehp_04/helpdata/EN/1b/325d4217139041e10000000a1550b0/content.htm for Unit Translation creation.
    You would need to ensure that unit translations are available in T006 table.
    --Priya

  • Alternate Unit of Measure Conversion Rule Error

    We want to sell Cement by the Ton, the base unit of measure its kilograms.
    But there its an error on the Material Master and the rule of conversion between Ton and Kilograms its 1 to 1.
    First I try to change it then I tried to enter a new one with TNE (Metric Ton) and in both cases after I enter 1,000 on the kilogram box,  SAP returns a 1 and in the bottom bar a green icon and the message: " units of measure have been verified and corrected" (translated)
    Its there some menu where I can correct these conversion rules?
    Thanks

    Hi Carlos
    We had lot of trouble with unit of measures in one of our projects.
    The rule is you can't change base unit of measure untill all open objects are completed. The open objects typically are Sales Orders, production order, purchase orders, etc. If you try to chnage Base unit of measure, SAP gives you an error with list of open objects.
    Second rule is it should be the smallest unit of measure if possible. For ex- you can't have base unit as Kilos and then alternate unit of measure as Grams. In this case Grams should be the smallest unit of measure.
    But once all open objects are closed and Base Unit is chnaged, I have not seen any problems in the previous transactions. We have done it multiple times.
    Another alternative to get out of this is, discard this material and create a new one with correct unit of measures.
    Hope this helps.
    Mankai

  • ALternate Unit of Measure as a Order unit in PO

    Hi everyone,
    I have a problem while ordering the Quantity in PO with alternate unit which is maintained in MMR. The problem is
    in MMR, I have maintained EA as the UOM and PAC as the Alternate unit of measure.
    while in PO, i am trying to give the 'Order Unit (OUn) as the PAC which is the alternate unit maintained. But it is not accepting and
    again reverting back to EA. i couldnt find out the solution. But some POs for that material is already ordered as PAC unit.
    Could it be problem with the MMR ?
    Regards
    Siva

    HI,
    Go to Inforecord of that material with that vender on that plant.
    Change Inforecord(me12)...here in general data...change the order unit.
    system will give the conversion factor as u defined in material master.
    Hope Help U !
    Regards,
    Pardeep Malik

  • Report Data in Alternate Unit of Measure

    Hi
    We are working on Unit of measure Conversion for this we are following “How To….Report Data in Alternate Units of Measure” document. We did all the steps as mentioned in the document still this is not working. All results are showing zeros with same units of key figure qty like EA, ROl, Boxes and so on. We want to convert this into Cartons and Pallets. My question is is there any thing we need to do which is not mentioned in this white paper.
    For example maintaining Conversion Factor in R/3 side?
    Do we need to add Conversion factor Key figure to Transfer Structure and Info cubes?
    (Which is not mentioned in the white paper) if so which field we need to map this in Transfer Structure?
    We are in Version 3.5
    Thanks
    Naga

    Naga,
    For your first question.....you can "maintain" different units of measure in 0MAT_UNIT, but at one time you can report on only one alternate unit.
    For your second question, I have a feeling that it is the problem with your enhancement to the std SAP code which is mentioned in the How to Paper. After you have done the enhancements did you activate the programs again? If there is somebody with you who is good in ABAP just run this enhancement through him.
    Also just make sure you have followed everystep in that how to document, including the query designer part of it.
    According to the logic of that paper, if the alternate unit is not available, then it is supposed bring back data in base unit, it is not supposed to error out. Check your ehancement piece again.
    Thanks
    Yashu Raj

  • While making changes in alternate Unit of measure CAR it makes changes

    While making changes in alternate Unit of measure CAR it makes changes in other alternate Unit of measure KAR.
    Both are having same ISO unit CT.Please suggest why it is happening.

    your units have probably a conversion rate to the SI unit in its definition.
    you can see this in CUNI, open your unit in detail and look at the lower left  part

  • Order qty by alternate unit of measures

    Hi All,
    In casting senario I want to map follwing.
    I have created a material having UOM as "g"  i.e. grams and maintained a conversion factor in alternate unit of measure to convert it to "MM" i.e. milimeters. I have also maintained alternate unit of measure in work scheduling view. Now when I create the order its in MM which is correct but I want to restrict order qty to 500 mm.
    Means if the requirement is generated for say 650 mm length then order qty should be 2 having 500 mm length each.
    How do i do this? Please advise.
    Regards,
    UG

    Dear ,
    You can achieve the same by keeping Fixed Lot Size FX  and keep the quantity as 500 in the same UOM at material master level -MM02. in MRP1
    Or if you want that 500 mm  is your Maximum Order Qty , then you can mention the same in Maximum Lot Size  field in MRP1
    Try and revert back
    Regards
    JH

  • How to report on Alternate Units of measure

    Hi ,
    I am trying to implement the unit conversion ..i have few basic questions..
    1)Do we need to have the 0MAT_UNIT in the cube/ODS
    2)for 0material do i specifically need the base unit of measure as unit for the attribute conversion factor..
    How do i go ahead if my conversion factor has a different unit..
    3)In my scenario i am trying to do unit conversion on a keyfigure which has unit as billing qty in SKU..Do I need to do anything different in this case in order to convert to a diff unit..
    Had changed the code given in the how to do doc..The report gave all the values as zero.
    Pl suggest.
    Appreciate ur inputs.
    Regards,
    G.V

    I am using BW 3.5 .
    Loaded/activated both 0material and omat_unit.
    0MAT_UNIT is not maintained in the ODS/CUBE.
    The keyfigure i am trying to convert to alternate unit of measure is billing qty in SKU which has billing qty in SKU
    as unit to that quantity..
    The user input variable for alternate unit of measure is defined on the unit billing qty in SKU..
    when i debug it is not processing through this loop..
    IF i_step = 0 AND i_vnam = 'YUOMCNVF' AND i_iobjnm = '0MATERIAL'.
    read material and base uom from variables
    LOOP AT i_t_var_range INTO l_s_var.
    CASE l_s_var-iobjnm.
    WHEN '0MATERIAL'. l_material = l_s_var-low.
    WHEN '0BASE_UOM'. l_base_uom = l_s_var-low.
    ENDCASE.
    ENDLOOP.
    Pl advise..

  • Alternate units of measure

    Hi,
    In order to implement the Alternate units of measure -
    I need to implement user exit and activate enhancement RSR0001. In the description below is listed what to implement of includes. In the function group XRSR - I have added the code to the includes ZXRSRTOP and ZXRSRU01. These are both a part of the group. But the last one ZXRSRF01 is not in the include folder. I tried to create an include by right click on the include folder and choose create - I named it ZXRSRF01 and copied the code into it. But it is still not to be found in the XRSR function group and when I check the program the get_form call raises and error in the code of the include ZXRSRU01. How to get the include in the function group or is there another solution?
    From SAP - How to...report data in alternate units of measure.
    3.7 User Exit for Variables
    Implement user exit for variables and activate enhancement RSR00001.
    ***INCLUDE ZXRSRTOP.
    Enhancement: Alternate U.o.M.
    DATA: g_aunit TYPE /bi0/oimat_unit.
    ***INCLUDE ZXRSRU01.
    Enhancement: Alternate U.o.M.
    DATA:
    l_s_range TYPE rsr_s_rangesid,
    l_s_var TYPE rrs0_s_var_range.
    l_dummy(72) TYPE c. "delete
    DATA:
    l_factor TYPE f,
    l_factor1 TYPE f,
    l_factor2 TYPE f,
    l_msgv1 LIKE sy-msgv1, "insert
    l_msgv2 LIKE sy-msgv2, "insert
    l_msgv3 LIKE sy-msgv3, "insert
    l_material LIKE /bi0/pmaterial-material,
    l_base_uom LIKE /bi0/pmaterial-base_uom.
    Called after user input
    IF i_step = 3.
    Get variable for alternative unit entered by user
    Validate entry and store as global variable
    READ TABLE i_t_var_range WITH KEY vnam = 'YTAUNIT' INTO l_s_var.
    IF sy-subrc = 0.
    TRANSLATE l_s_var-low TO UPPER CASE. "#EC TRANSLANG
    CALL FUNCTION 'CONVERSION_EXIT_CUNIT_INPUT'
    EXPORTING
    input = l_s_var-low
    language = sy-langu
    IMPORTING
    output = g_aunit
    EXCEPTIONS
    unit_not_found = 1
    OTHERS = 2.
    IF sy-subrc <> 0.
    Error: Please enter a valid unit of measure
    l_msgv1 = 'Unknown unit of measure:'.
    l_msgv2 = l_s_var-low. "insert
    l_msgv3 = '. Please enter a valid unit of measure.'.
    CALL FUNCTION 'RRMS_MESSAGE_HANDLING'
    EXPORTING
    i_class = 'R9'
    i_type = 'E'
    i_number = '000'
    i_msgv1 = l_msgv1
    i_msgv2 = l_msgv2 "change
    i_msgv3 = l_msgv3
    EXCEPTIONS
    dummy = 0
    OTHERS = 0.
    CALL FUNCTION 'RRMS_MESSAGES_SHOW'.
    CALL FUNCTION 'RRMS_MESSAGES_DELETE'.
    sy-subrc = 4.
    RAISE again. "#EC *
    ENDIF.
    ENDIF.
    ENDIF.
    Called from "Get Attribute" Function (Modification)
    I_VNAM Attribute (not the name of the formula variable)
    I_IOBJNM InfoObject
    I_T_VAR_RANGE Contains characteristic value, attribute value,
    unit of measure, query key date
    IF i_step = 0 AND i_vnam = 'YUOMCNVF' AND i_iobjnm = '0MATERIAL'.
    read material and base uom from variables
    LOOP AT i_t_var_range INTO l_s_var.
    CASE l_s_var-iobjnm.
    WHEN '0MATERIAL'. l_material = l_s_var-low.
    WHEN '0BASE_UOM'. l_base_uom = l_s_var-low.
    ENDCASE.
    ENDLOOP.
    get factor for base UoM
    PERFORM get_factor USING l_material l_base_uom l_factor1.
    get factor for alternate UoM
    PERFORM get_factor USING l_material g_aunit l_factor2.
    return conversion factor for variable
    IF l_factor2 <> '0.0'.
    l_factor = l_factor1 / l_factor2.
    e_meeht = g_aunit. "insert
    ELSE.
    When the UoM conversion is not maintained, instead of showing 0, the
    base UoM with a factor of 1 is used. Therefore, the user sees MIXED
    VALUES in the total line and knows right away that there is something
    wrong. That way it’s easier to track inexistent conversion factors.
    l_factor = 0. "delete
    l_factor = 1. "insert
    e_meeht = l_base_uom. "insert
    ENDIF.
    CLEAR l_s_range.
    l_s_range-sign = 'I'.
    l_s_range-opt = 'EQ'.
    l_s_range-low = l_factor.
    APPEND l_s_range TO e_t_range.
    e_meeht = g_aunit. "delete
    ENDIF.
    ***INCLUDE ZXRSRF01.
    *& Form get_factor
    Get conversion factor from /bi0/pmat_unit
    FORM get_factor USING i_material TYPE /bi0/oimaterial
    i_mat_unit TYPE /bi0/oimat_unit
    e_factor.
    TYPES:
    BEGIN OF ys_mat_unit,
    material TYPE /bi0/oimaterial,
    mat_unit TYPE /bi0/oimat_unit,
    numerator TYPE /bi0/oinumerator,
    denomintr TYPE /bi0/oidenomintr,
    END OF ys_mat_unit.
    DATA:
    l_s_mat_unit TYPE ys_mat_unit.
    STATICS:
    s_t_mat_unit TYPE SORTED TABLE OF ys_mat_unit
    WITH UNIQUE DEFAULT KEY.
    CLEAR: l_s_mat_unit, e_factor.
    READ TABLE s_t_mat_unit INTO l_s_mat_unit WITH KEY
    material = i_material
    mat_unit = i_mat_unit.
    IF sy-subrc <> 0.
    SELECT SINGLE * FROM /bi0/pmat_unit
    INTO CORRESPONDING FIELDS OF l_s_mat_unit
    WHERE material = i_material
    AND mat_unit = i_mat_unit
    AND objvers = 'A'.
    IF sy-subrc = 0.
    INSERT l_s_mat_unit INTO TABLE s_t_mat_unit.
    ENDIF.
    ENDIF.
    IF l_s_mat_unit-denomintr <> 0.
    e_factor = l_s_mat_unit-numerator / l_s_mat_unit-denomintr.
    ENDIF.
    ENDFORM. " get_factor
    Hope someone can help.
    Thanks

    Hi Karin,
    I am also facing the same problem for alternate units of measure...i tried to access the path
    websmp201.sap-ag.de/~sapdownload/011000358700000488512003E/Howto_alternate_uom5.pdf
    but it is not found...can u please give me this document if u have it with you.?
    Thanks,
    Vijaya

  • Report Data in to two alternate Unit of Measures

    Hi
    We Implemented "How to Report Data in to two alternate Unit of Measure". I have a question
    1 Could we maintain Two alternate Unit of Measures for one Base Unit of Measure?
    For example if Base unit is EA ( Each) we need to maintain this as CAR( Carton) and PAL ( Pallet).
    Thanks
    Naga

    Hi Naga,
    Are you talking about Qty Unit conversion. We can surely maintain CAR,EA,PAL and all. The Numerator and Denoms are maintained in T006. And accordingly the conversion happens.
    Apart from that you can have your own customized Qty conversion using Transaction 'RSUOM'.
    Lemme me know if this helps.
    -Bikas

  • Issue with Alternate unit of measure

    Here in my production client which creating a material in April they have created with Base unit of measure = G and alternate unit of measure = EA
    ! EA = 60G....But actually they should have maintain 1 EA = 50g....Lot of docs got posted from April onwards...
    Movement types posted were 641,561, 562,101,102,601,653
    Now is there any possiblity to rectify it????

    Basically you need to correct your material master and then adjust the quantity with a physical inventory as Manoj already suggested.
    However, you should at least check each movement related to sales  like the 641, 601 and 653 movements if it was done in the alternative unit or in the base unit . MB51 can give you this info in the detailed report.
    you then have to analyze if you billed too much or too less to your customer.
    This should then be rectified before you adjust your inventory, because you may get even more problems with posting if you get a  customer complaint or a return which need to be posted with the old incorrect conversion ratio. Otherwise you may have to adjust your inventory a second time after such event ocurs.

  • Stock display with Alternate unit of measure

    Hi All,
    is there any report in SAP, which displays the warehouse stock with Alternate Unit of measure. I did try in MB52. It was showing only in BUM. Please help ASAP.
    Ayesha

    Hello Ayesha,
    We had the same requirement. So we copied MB52 to ZMB52 and added a new selection for the AUM. Additional coding was also done for the UoM conversion.
    Cheers !
    Rajesh

  • Alternate unit of measurement

    Hi
    Our client wants to use alternate unit of measurement from Square Feet to PCS. The conversion factor is not constant, we have aggreed to use an average conversion factor. Stock posting will be done in square feet and PCS will be used in reporting only.
    Question is is there a way to avoid user from entering PCS in stock posting transactions (GR GI for production purchase or sale orders) by mistake. PCS should not be allow for inventory posting. It should be only for display.
    Regards
    Abhishek Rai

    You can restrict the use of certain alternative units only with userexits, which can be quite messy, as you have to make sure that it is not taken in inventory managment, in sales order, production order .....
    Have you thougt about using proportion units?
    http://help.sap.com/saphelp_46c/helpdata/en/30/e1a993db3611d185160000e82013e8/frameset.htm

  • How to Mass update Alternate Unit of Measurement ?

    Hi Gurus,
    How to update Alternative Unit of Measurment for 1000 items at a time.
    Required solution of Mass updatation of Alternate Unit of Measurement
    Guide in this.
    Prakash

    Hello, Prakash,
    transaction MASS -> Object BUS1001"Material" -> table MARM "Units of Measure for Material", though it is usefull only for changes of conversion factors. Otherwise, it's time for LSMW/BatchInput/Catt, what ever you prefers.
    TomT

  • Reporting Data in Alternate Units of Measure

    We have a requirement to report data in base unit of measure and also in pounds and kilograms. I have read the paper "How to Report Data in Alternate Units of Measure".  My problem is that in our R/3 system the conversion from base unit of measure to pounds is maintained, but no conversion from base unit of measure to kilograms is maintained.  In BW, I have 0MAT_UNIT for conversion to pounds but not to kilograms.  For the solution to work, am I correct in thinking that the conversion to kilograms must exist in 0MAT_UNIT?
    Also, the paper states that it is applicable to BW releases 2.0A to 3.1C.  Those of you on BW 3.5 - is there new functionality or a different way of handling reporting in alternate units of measure?
    Thanks for your help,
    Gail Bodner

    Gail,
    Nothing new in 3.5 for UoM conversion. It will still have to be the way described in the How To paper.
    Maintin the conversion in R/3. Also, Pounds to KG is a standard coversion - you can hard code it too. Issue in UoM conversion comes in where you cut across type of uints, i.e. from vol. to weight. Then additional information like density is needed but within the same area, it shouldn't be a problem.
    Cheers
    Aneesh

Maybe you are looking for

  • Photoshop CC slows down suddenly, for several minutes

    Hi! I have a problem with Photoshop CC. I sit on a 27" iMac, 8GB RAM and an i5 processor, OS X Mavericks, Wacom intuos Pro tablet. My problem, that suddenly occurs is tha Photoshop CC suddenly slows down to a halt. No error messages, it just gets ver

  • How to find Goods Receipt Number particular to Service Entry Sheet Number.

    Hi Experts,   In one of my reports  i need to bring purchase order ,service entry sheet, goods receipt number . In ekbe i am getting the purchase order and its service entry sheet while keeping BEWTP = 'D'. so i am getting purchase orders and their s

  • How to protect both access (http and https) with a Policy Agent

    Hi, During the installation of a web Policy Agent (i.e. Policy Agent for IIS) we have to choose the protocol (and port) of the web server we want to protect. If we have an IIS with secure (https) and non secure (http) applications, how we manage this

  • Panel not showing

    Hello, I'm running in (another) issue trying to make a Photoshop panel - the short version is that it doesn't appear in the extensions list. I took Maria's video as a walkthrough, so: 1) I've the FlashBuilder project, everything's fine (if I move for

  • Screen enhancement for F-53

    Hi, I need to enable the PAYMENT METHOD field when we simulate the document (clearance) in F-53. Is there any screen -exit / screen variant which will help achieve this. Kindly suggest. Thanks in advance.