Core switches between 2 data centers
Existing data center has 2 X Cisco 6500 series core switches, new data center has 2 X Cisco nexus core switches. For the connection between 2 data center, it will be using leased line. To establish the network connection for both side, should it use trunk port with layer 2 connection directly or layer 3 ip routing (configure the ip on switchport interface) ? What is the better approach for its design? Please share your idea.
Disclaimer
The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
Liability Disclaimer
In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
Posting
Normally, when dealing with off-site traffic, L3 is better as it limits traffic to only what needs to go off-site.
However, as you're dealing with data centers, it's no longer uncommon that there's need to share L2 between them. So, much depends on what your needs are.
Similar Messages
-
We have two Nexus 7000, and I need use them with OTV between two data Centers separated 25 miles, but I don´t know what are the optimal values about bandwidth and delay (ms) for extended VLANs IDs (production and DAG replication) for Microsoft Exchange environment. Can somebody tell me please which are the values required for operate OTV in optimal conditions in this case? We have about 35 000 users that will use that platform of email. Thanks a lot for your comments. Regards.
We have two Nexus 7000, and I need use them with OTV between two data Centers separated 25 miles, but I don´t know what are the optimal values about bandwidth and delay (ms) for extended VLANs IDs (production and DAG replication) for Microsoft Exchange environment. Can somebody tell me please which are the values required for operate OTV in optimal conditions in this case? We have about 35 000 users that will use that platform of email. Thanks a lot for your comments. Regards.
-
WAN Vlan optimization between 2 Data Centers - 4451 Router
Hello Group gurus,
I have little odd question
We have 2 Data Centers, we have dedicated 1Gig link across them. we want to optimize certain Vlan traffic across them.
we have 4451 routers installed at each location and OSPF running for end subnets to know each other. but that is routing part completed.
however how can we utilize UCSE chassis of 4451 to optimize vlan traffic across data center is still a query.
I tried to find out document on google but specific to my requirement has not seen on.
if someone already set up this type of scenario, please help.
Thanks in advanceHi John, I think it's best to use the right equipment for the job. If you've already got a router in place and you're not in a campus/metro/ISP environment, it's not really prudent to use another router. A simple layer 2 or layer 3 switch can accomplish this and give you plenty of ports at a much better price per port.
You may want to look in to the SG300 series switch if you want something that can handle route load and give ample amount of ports. -
Adding 2 New SItes between 2 Data Centers
I have a current Site installed with default settings (no additional sites/subnets/site links), and we are plannig on creating 3 new DCs in our remote Data Center, which will be the second site. I want to seperate desktop traffic between the 2
Data Centers. My question is, what is the best way to do this? I want to keep the Deafult First Name Site as a catch -all for all subnets that may be missed.1. Why do you wish to keep clients from accessing DCs in the datacenter? What harm do you think may occur?
2. Assuming a two-site topology with a site link associating each of them won't accomplish what you want, but can *reduce* the amount of authentication traffic from one site to another.
3. Keeping the Default First Site Name is fine - it won't hurt anything, but using it as a 'catch-all' for IP subnets not registered in AD indicates poor IP address management. You should address that issue first.
4. It might be possible to completely eliminate client auth traffic in one site from reaching another site by creating three sites in series (Site A <-> Site B <-> Site C) and disabling "Bridge all site links". With Site Link Bridging
disabled, the connection from Site A to Site C will no longer be transitive and clients that are members of that site will not send authentication requests to DCs in Site C. However, that's a lot of 'hoops' to jump through just to address a problem I'm
not sure is all that important.
-ds
David Shaw [MSFT] -
Switching between mobile data and wifi for emails only
I tried to look myself, but could not find it....Is there a way that i can set my emails on my phone to only download when connected to wifi? I don't want to use unnecessary data when I am at the office (I do have wifi at home) and on my pc, but also don't want to switch off all mobile data as I won't be able to receive instand messages then. We are unfortunately not allowed to link our phones on our office wifi and data in South Africa is quite expensive when you run out of your data bundle from your provider.
I am on the Blackberry 10 OS.I am a little puzzled by the libraries and switching between the libraries. My personal computer has the majority of the movies and content that would be transfered to the appletv. I chose to only select a minimal amount of content (of movies and tv shows, music via playlists) so there would be space left that would hold photos. Also, i just want to send over only what I want to view (manual synch) If I switch to my Kids library, it streams all the content well (movies & tv shows)(which is fine and streams well) If I switch back to my library, it shows every movie, every tv show, hundreds of music playlist that I did not choose to see. (stream mode) The only fix is to reboot the computer, and all is well. anyone experience this issue?
-
Can portal session cookies be used between two data centers
OAS generates the following header information and session information for my application. However when I need to failover the originating OAS datacenter into my hot stand-by for maintenance or upgrades, the OAS in the other datacenter responds with a 503 web error. We are using Akamai's GTM to manage the liveness of the datacenter, so we would need the hot stand-by OAS portal in that datacenter to return a 302 error code. Is there some method that we can add to our portal application which would always return a 302 error code.
See header information collected through wfetch. The 503 error is caused by the hot stand-by data center not accepting or recognizing the cookie. Both OAS datacenters are IDENTICAL in Oracle levels, application levels, web servers, portals and OS patches.
resolve hostname "170.107.183.32"WWWConnect::Connect("170.107.183.32","80")\nsource port: 2182\r\n
GET /portal/pls/portal/PORTAL.wwsec_app_priv.login?p_requested_url=%2Fportal%2Fpls%2Fportal%2FPORTAL.home&p_cancel_url=%2Fportal%2Fpls%2Fportal%2FPORTAL.home HTTP/1.1\r\n
Accept: */*\r\n
Accept-Language: en-us\r\n
Accept-Encoding: gzip, deflate\r\n
User-Agent: Mozilla/4.0 (compatible; MSIE 6.0; Windows NT 5.1; SV1; .NET CLR 1.0.3705; .NET CLR 1.1.4322; .NET CLR 2.0.50727; .NET CLR 3.0.04506.30)\r\n
Host: www.thomson-pharma.com\r\n
Connection: Keep-Alive\r\n
Cookie: ORA_WX_SESSION="10.225.8.30:80-1#2"; portal=9.0.3+en-us+us+AMERICA+3D66674E7EED0801E04400144F41424E+BBAA98EEB32D58C086231A8D6CBE2E5D402D89B0E79D83A18C668BB0CA7417B4044DEA389C8B50DD37D9272A24B4753B22F29978861DE14503F8B9BEDC2014654B26A434CF074F4D8749B88610ADADF5084A90ADBF749E2A; DATACENTER=EAGAN\r\n
\r\n
HTTP/1.1 503 Service Unavailable\r\n
Cache-Control: private\r\n
Content-Type: text/html\r\n
Set-Cookie: ORA_WX_SESSION="10.237.138.33:80-1#2"\r\n
Set-Cookie: portal=; expires=Wednesday, 27-Dec-95 05:29:10 GMT; path=/\r\n
Connection: Keep-Alive\r\n
Keep-Alive: timeout=5, max=999\r\n
Server: Oracle-Application-Server-10g/10.1.2.0.2 Oracle-HTTP-Server OracleAS-Web-Cache-10g/10.1.2.0.2 (N;ecid=208440262161,0)\r\n
Content-Length: 710\r\n
Date: Fri, 26 Oct 2007 14:58:07 GMT\r\n
\r\n
Thanks -JohnHi John,
This question is probably more appropriate in one of the Portal forums, but perhaps you can take a look at the information in section C.5 Configuring the Portal Session Cookie in Appendix C of the Portal Configuration guide.
Here is a link: http://download.oracle.com/docs/cd/B14099_19/portal.1014/b19305/cg_app_c.htm#sthref1907
Regards,
Peter -
Hi,
We've recently inherited a job that another company was doing, so we've had our hand slightly forced on the kit and overall topology involved, however that's all fine and we can make it work.
This is a collapsed core topology with core and access switches, split over 3 blocks (fibre connections between), one core switch/stack is in block B and the other in block C, with access switches throughout.
They require all access switches to be connected to the Core in B and the Core in C, and then obviously cross connects between the two cores.
They state:
"Core switches shall be linked with 2x 1Gbps links bonded into a standard compliant Etherchannel"
"Uplinks between access and core switches shall be non-blocking - for example equal cost load balancing at layer 3, or layer 2 bonded multi-chassis Etherchannel"
The specced kit for the core are 3850's, in an ideal world I'd use VSS (Virtual Switch System) to achieve the above statements beyond repute; but this is only supported on 4500/6500 and Nexus platforms.
Do we think a cross stack etherchannel (LACP between both core switch stacks) would satisfy the above statements? Or the statements may just be badly worded...
I look forward to your thoughts and views on this! Thanks!Disclaimer
The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
Liability Disclaimer
In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
Posting
As the others have noted, the 3850s, to stack, are restricted to the length of the longest stack cables.
As you have noted, VSS physical units would allow the "logical" unit to be far apart.
For a "small" VSS core, the 4500-X might be an idea unit. (Other than cost, the 4500 would be a better choice for a core device.)
Something to watch for, or understand, when running VSS, Etherchannel doesn't load balance as it does on a single chassis or stack. VSS will avoid using the VSL cross link unless it must.
As many access switches, today, support basic L3 routing, you might also determine whether a L3 edge would be a suitable alternative choice. It would allow retention of the 3850s and can offer some advantages even over VSS. (Where VSS is very nice [as too the Nexus] supporting servers with Etherchannels.) -
Difference between core switch types WS-C3750X-12S-S and N3K-C3524P-10G?
Hello All,
I am new to this domain and yet have to look after the setup of our datacenter for a new branch. Could any one of you provide difference between core switch types WS-C3750X-12S-S and N3K-C3524P-10G!
Thanks in advance!!N3K-C3524P-10G
24 fixed 1/10-Gbps SFP+ ports; upgradeable to 48 with a valid license
Line-rate Layer 2 and Layer 3 throughput of up to 480 Gbps
Compact 1RU form factor
Dual redundant color-coded power supplies
Four redundant color-coded fans -
Inform users on unsaved data when switching between/starting new TaskFlows?
Hi
In our case, we are using the multiTaskFlow concept to dynamically start new TaskFlows in Tabs. The simple requirement is to have a generic way to inform users on modified unsaved data when switching or starting new TaskFlow
I did research in google for answers, but did not found anything working.
For example, I added following checks (df=dirtyFlag) just before switching between Tabs and Menu-items:
boolean df1 = am.getApplicationModuleDef().isDirty();
boolean df2 = ControllerContext.getInstance().getCurrentRootViewPort().isDataDirty();
boolean df3 = ControllerContext.getInstance().getCurrentViewPort().isDataDirty();
boolean df4 = AdfFacesContext.getCurrentInstance().getDirtyPageHandler().isDataDirty();
boolean df5 = am.getTransaction().isDirty();
boolean df6 = am.getDBTransaction().isDirty();
boolean df7 = bindingContext.getDefaultDataControl().isTransactionDirty();
boolean df8 = dcBindingContainer.getDataControl().isTransactionModified();
boolean df9 = dcBindingContainer.getDataControl().isTransactionDirty();
Start Application and perform a TAB switch without searching or changing anything
df1 true
df2 false
df3 false
df4 false
df5 false
df6 false
df7 false
df8 false
df9 false
Within a TaskFlow I perform a SEARCH and perform a TAB switch, flags change to following:
df1 true
df2 true
df3 true
df4 true
df5 true
df6 true
df7 false
df8 false
df9 false
I MODIFY values within TF and perform a TAB switch, flags remain same and regardless what I do, they remain so:
df1 true
df2 true
df3 true
df4 true
df5 true
df6 true
df7 false
df8 false
df9 false
Do you know a working approach?
Thanks in advance!Hi,
its for when you leave a view, not when you switch task flows in a page. To get back to your question, one thing you forgot to mention is what data control state is it that the task flows have: shared or isolated? If they have a shared state then only a single transaction is on and you should be able to tell the dirty state by calling
boolean df2 = ControllerContext.getInstance().getCurrentRootViewPort().isDataDirty();
However, if the task flow is in isolated mode then you will need to get a handle to the data control frame used by that task flow.
BindingContext ctx = oracle.adf.controller.binding.BindingUtils.getBindingContext();
String frameName = ctx.getCurrentDataControlFrame();
DataControlFrame frame = ctx.findDataControlFrame(frameName);
boolean isDirty = frame.isTransactionDirty();
//see: http://docs.oracle.com/cd/E15051_01/apirefs.1111/e10653/oracle/adf/model/DataControlFrame.htmlHowever, this information is only available from within the task flow, which means to check this from the outside you need to provide a mechanism to get to this information (contextual events would be an option. You define a contextual event receiver on the task flows that when called checks the current transaction state and then "fires" the answer back to the caller, which then obtains a map of task flow transaction states to check before navigating away or switching task flows.
Frank
Edited by: Frank Nimphius on Apr 11, 2013 2:48 PM -
Coherence - grid-data replication between data centers
Hi All ,
We have two data centers , each having a coherence data-grid. How can we replicate cached data in grid between these two data centers ? I looked at the , http://coherence.oracle.com/display/INCUBATOR/Push+Replication+Pattern
but , ? I need more information on this ? Can someone direct me to some useful links and documentation ?Unfortunately, what you've seen is about as far as it goes, I'm afraid.
I've just got it working, but it was a pain to have to dig through so much API docs and source code in order to get it working. It really should have a much better set of documentation, including a tutorial, IMHO. The crazy thing is, once you have got it working, it turns out it's not actually that difficult!
I've also posted some questions on the Incubator forums, but they've mainly fallen on deaf ears (except for one guy, Neville, who I don't think works for Oracle.) I've been trying to get PublishingTransfomers to work, but the documentation for them is very, very poor. Also, none of the "examples" have any Transformers.
It's a shame that something so heavily "pushed" at the Coherence SIGs, PR, is so poorly documented/supported... (Take a look at the low post counts of those supporting it from Oracle, and the number of unanswered messages.)
Anyway, give it a shot and let me know if you have any specific questions. I guess they should really be posted on the Incubator forum rather than here, but as it's such a "ghost town" over there I wouldn't be too hopeful of a reply! :)
NB. Make sure you download and look at the Examples: http://coherence.oracle.com/display/INCUBATOR/Coherence+Incubator+Examples -
HSRP between 2 access switches and 2 core switches
Hi I am looking for running HSRP between 2 access switches and 2 core switches for client PC and Server network’s next-hop redundancy as per attached setup.
As you can see I have used one /29 network for connecting CORE & ACCESS switches & configure Interface VLAN10 (Layer 3 SVI) with shown IPs and standby IP (VIP).G0/1 on Access Switches & G2/1 on Core Switches are access ports for VLAN10.
There is a L2 Trunk interconnecting Core-Main/Backup & as well as Access-Main/Backup Switches allowing VLAN10 to allow VLAN10’s HSRP packets to pass through (apart from other HSRP instances).
Below are the HRSP & Trunk configuration on Core and Access Switches please have a look and suggest if they are correct in term of HSRP implementation, as I can see on both side HSRP master & standby status are fine as desired, but I can’t ping VIP of ACCESS Switch from CORE switch, but the VIP of CORE switch I can ping from ACCESS switch.
Access-Main
interface GigabitEthernet0/1
description ***Connected to CR-SW-01 PORT G2/1***
switchport access vlan 10
switchport mode access
load-interval 30
interface GigabitEthernet0/2
description ***Connected to AC-SW-01 & AC-SW-02 for HRSP***
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 10,40
switchport mode trunk
load-interval 30
interface Vlan10
description ***Connected to CR-SW-01 PORT G2/1***
ip address 10.10.11.1 255.255.255.248
standby 1 ip 10.10.11.2
standby 1 timers msec 200 msec 750
standby 1 preempt delay minimum 180
standby 1 authentication accvlan10
Access-Backup
interface GigabitEthernet0/1
description ***Connected to CR-SW-02 PORT G2/1***
switchport access vlan 10
switchport mode access
load-interval 30
interface GigabitEthernet0/2
description ***Connected to AC-SW-01 & AC-SW-02 for HRSP***
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 10,40
switchport mode trunk
load-interval 30
interface Vlan10
description ***Connected to CR-SW-02 PORT G2/1***
ip address 10.10.11.3 255.255.255.248
standby 1 ip 10.10.11.2
standby 1 priority 10
standby 1 timers msec 200 msec 750
standby 1 preempt delay minimum 180
standby 1 authentication accvlan10
Core-Main
interface GigabitEthernet2/1
description ***Connected to AC-SW-01 PORT G0/1***
switchport access vlan 10
switchport mode access
load-interval 30
interface GigabitEthernet2/2
description ***Connected to CR-SW-01 & CR-SW-02 for HRSP***
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 10,20
switchport mode trunk
load-interval 30
interface Vlan10
description ***Connected to AC-SW-01 PORT G0/1***
ip address 10.10.11.4 255.255.255.248
standby 1 ip 10.10.11.5
standby 1 timers msec 200 msec 750
standby 1 preempt delay minimum 180
standby 1 authentication crvlan10
Core-Backup
interface GigabitEthernet2/1
description ***Connected to AC-SW-02 PORT G0/1***
switchport access vlan 10
switchport mode access
load-interval 30
interface GigabitEthernet2/2
description ***Connected to CR-SW-01 & CR-SW-02 for HRSP***
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 10,20
switchport mode trunk
load-interval 30
interface Vlan10
description ***Connected to AC-SW-02 PORT G0/1***
ip address 10.10.11.6 255.255.255.248
standby 1 ip 10.10.11.5
standby 1 priority 10
standby 1 timers msec 200 msec 750
standby 1 preempt delay minimum 180
standby 1 authentication crvlan10Hi Rick thanks once again, so I am assuming I should use to configure as below and still one /29 subnet I can use to connect these Switches with the above static routings.
Access Switch-Main
interface Vlan10
description ***Connected to CR-SW-01 PORT G2/1***
ip address 10.10.11.1 255.255.255.248
standby 2 ip 10.10.11.2
standby 2 timers msec 200 msec 750
standby 2 preempt delay minimum 180
standby 2 authentication accvlan10
ip route 192.168.20.0 255.255.255.0 10.10.11.5
Access Switch-Backup
interface Vlan10
description ***Connected to CR-SW-02 PORT G2/1***
ip address 10.10.11.3 255.255.255.248
standby 2 ip 10.10.11.2
standby 2 priority 10
standby 2 timers msec 200 msec 750
standby 2 preempt delay minimum 180
standby 2 authentication accvlan10
ip route 192.168.20.0 255.255.255.0 10.10.11.5
Core Switch -Main
interface Vlan10
description ***Connected to AC-SW-01 PORT G0/1***
ip address 10.10.11.4 255.255.255.248
standby 1 ip 10.10.11.5
standby 1 timers msec 200 msec 750
standby 1 preempt delay minimum 180
standby 1 authentication crvlan10
ip route 192.168.40.0 255.255.255.0 10.10.11.2
Core Switch -Backup
interface Vlan10
description ***Connected to AC-SW-02 PORT G0/1***
ip address 10.10.11.6 255.255.255.248
standby 1 ip 10.10.11.5
standby 1 priority 10
standby 1 timers msec 200 msec 750
standby 1 preempt delay minimum 180
standby 1 authentication crvlan10
ip route 192.168.40.0 255.255.255.0 10.10.11.2 -
Long distance application failover between data centers.
Hello:
I am working a project where there is a requirement to have a primary server and a secondary for application failover. The requirements dictate that the servers must be geographically separate at separate data centers but yet on the same IP subnet so that heartbeat messages are not natively routed. What protocol can I use to bridge the subnet over an IP routed network? GRE? L2TP?GRE will not work as according to the last information I have you cannot bridge over a GRE tunnel. We had one such application with similar requirements and we ended up using L2TPv3 that allows transparent LAN extension. We have not had any issues with it and if you are only going to use it for heartbeats you should not run into any performance issues. L2TPv3 does tend to drive the CPU utilization high in case you have a lot of data traversing the tunnel.
-
Sapmmc - jstart.exe keeps restarting, switching between green and yellow
Hi Friends,
I installed the SAP core server ( as part of SAP convergent charging) , but jstart.exe and dispatcher-1 process in sapmmc are noticed keep switching between yellow and green. when the jstart.exe turns green (all process running) , dispatcher-1 turns yellow (waiting to start) and when dispatcher-1 turns green (restart-yes) , jstart.exe turns yellow (some processes running). Only for a small duration , they both remain green (may be during transition).
Trace File is as below: Iam not sure as what is missing here to be installed, as it is complaining about JEE directory in
C:\usr\sap\C06\CCD09\j2ee\cluster\bin, which is not present., which was never installed as part of the installation.
trc file: "dev_jstart.new", trc level: 1, release: "711"
sysno 09
sid C06
systemid 562 (PC with Windows NT)
relno 7110
patchlevel 0
patchno 92
intno 20020600
make multithreaded, Unicode, 64 bit, optimized
profile C:\usr\sap\C06\SYS\profile\C06_CCD09_W2K8-Sap-01
pid 3596
ACTIVE TRACE LEVEL 1
ACTIVE TRACE COMPONENTS All, egi
Wed Oct 26 04:53:47 2011
trace logging activated, max size = 52428800 bytes, 2 versions
arguments :
arg[ 0] : C:\usr\sap\C06\CCD09\exe\jstart.EXE
arg[ 1] : pf=C:\usr\sap\C06\SYS\profile\C06_CCD09_W2K8-Sap-01
trc file: "C:\usr\sap\C06\CCD09\work\dev_jstart", trc level: 1, release: "711"
ACTIVE TRACE LEVEL 1
ACTIVE TRACE COMPONENTS All, egi
F
F [Thr 3600] Wed Oct 26 04:53:47 2011
F [Thr 3600] *** ERROR => SfCheckJeeVersion: Cannot find JEE binary directory C:\usr\sap\C06\CCD09\j2ee\cluster\bin. [sfxxmain.cpp 848]
trc file: "C:\usr\sap\C06\CCD09\work\dev_jstart", trc level: 1, release: "711"
ACTIVE TRACE LEVEL 1
ACTIVE TRACE COMPONENTS All, egi
F [Thr 3600] *** ERROR => SfCheckJeeVersion: Cannot find JEE application directory C:\usr\sap\C06\CCD09\j2ee\cluster\apps. [sfxxmain.cpp 857]
F ********************************************************************************
F Java environment properties (C:\usr\sap\C06\CCD09\work\jstart.jvm)
F root directory : C:\usr\sap\C06\CCD09\exe\sapjvm_6
F vendor : SAP AG
F version : 1.6.0_24
F cpu : amd64
F java vm type : server
F java vm version : 6.1.027 1.6-b07
F jvm library name : jvm.dll
F library path : C:\usr\sap\C06\CCD09\exe\sapjvm_6\jre\bin\server;C:\usr\sap\C06\CCD09\exe\sapjvm_6\jre\bin
F executable path : C:\usr\sap\C06\CCD09\exe\sapjvm_6\bin
F ********************************************************************************
F SAP extensions : available
F ********************************************************************************
I [Thr 3600] MtxInit: 30002 0 2
dispatcher trace
trc file: "C:\usr\sap\C06\CCD09\work\dev_dispatcher-1", trc level: 1, release: "711"
sysno 09
sid C06
systemid 562 (PC with Windows NT)
relno 7110
patchlevel 0
patchno 92
intno 20020600
make multithreaded, Unicode, 64 bit, optimized
profile C:\usr\sap\C06\SYS\profile\C06_CCD09_W2K8-Sap-01
pid 428
ACTIVE TRACE LEVEL 1
ACTIVE TRACE COMPONENTS All, egi
Wed Oct 26 06:22:16 2011
trace logging activated, max size = 52428800 bytes, 2 versions
arguments :
arg[ 0] : C:\usr\sap\C06\CCD09\exe\jstart.EXE
arg[ 1] : -appTrc
arg[ 2] : -nodeId=0
arg[ 3] : pf=C:\usr\sap\C06\SYS\profile\C06_CCD09_W2K8-Sap-01
arg[ 4] : -hostvm
arg[ 5] : -nodeName=dispatcher-1
arg[ 6] : -file=C:\usr\sap\C06\CCD09\config\jstart.config
arg[ 7] : -jvmFile=C:\usr\sap\C06\CCD09\work\jstart.jvm
arg[ 8] : -traceFile=C:\usr\sap\C06\CCD09\work\dev_dispatcher-1
arg[ 9] : -javaOutFile=C:\usr\sap\C06\CCD09\work\jvm_dispatcher-1.out
F
F Wed Oct 26 06:22:16 2011
F ********************************************************************************
F Java environment properties
F root directory : C:\usr\sap\C06\CCD09\exe\sapjvm_6
F vendor : SAP AG
F version : 1.6.0_24
F cpu : amd64
F java vm type : server
F java vm version : 6.1.027 1.6-b07
F jvm library name : jvm.dll
F library path : C:\usr\sap\C06\CCD09\exe\sapjvm_6\jre\bin\server;C:\usr\sap\C06\CCD09\exe\sapjvm_6\jre\bin
F executable path : C:\usr\sap\C06\CCD09\exe\sapjvm_6\bin
F SAP extensions : available
F ********************************************************************************
I [Thr 3828] MtxInit: 10000 0 2
M [Thr 3828] NiInit3: NI already initialized; param 'maxHandles' ignored (init=2;par=202;cur=2048)
M [Thr 3828] CCMS: AlInitGlobals : alert/use_sema_lock = TRUE.
M [Thr 3828] CCMS: Initalized shared memory of size 60000000 for monitoring segment.
M [Thr 3828] CCMS: Checking Downtime Configuration of Monitoring Segment.
M
M [Thr 3828] Wed Oct 26 06:22:17 2011
M [Thr 3828] CCMS: AlMsUpload called by wp 1004.
M [Thr 3828] CCMS: AlMsUpload failed for C:\usr\sap\C06\CCD09\log\ALMTTREE.DAT.
M [Thr 3828] CCMS: CCMS Monitoring Initialization finished, rc=0.
F
Please help.
Thanks.
Edited by: Zain Ahmed on Oct 26, 2011 9:07 PMHI,
Import the SAP profiles in SAP transaction RZ10: Utilities - Import profiles - of Active Server
OR
Check what messages do you have in jvm_server0.out, dev_server0.out and bootstrap traces,
also have a look at the note 142100.
The first problem is that in the SCS instance there are no running enqueue server as its starting line have no line break at the end in the start profile. Without this NT cannot parse the line. After adding the line break the enqueue server could start.
The second problem is that in the global dispatcher configuration for the LockingManager the en.port was set to 3201 instead of 3200 (which is correct as the SCS instance has the intance number 00).
After correcting these problems the J2EE engine could be started fine.
see similar threads
Dispatcher - Running but Dialog Queue info unavailable
/thread/96588 [original link is broken]
logon710
Message server not starting
Thanks
Swarup -
Error while switching between DC, DTR & web dynpro perspectives
Hi,
I am facing the following error while switching between DC, DTR & web dynpro perspectives.
A SWT error has occured.
It is recommended to exit the workbench.
Subsequent errors may happen and may terminate the workbench without warning.
See error log for more details.
Exit workspace?
When I click on 'Ok' and check out the log file....
!SESSION Nov 08, 2006 19:02:46.730 -
java.version=1.4.2_12
java.vendor=Sun Microsystems Inc.
BootLoader constants: OS=win32, ARCH=x86, WS=win32, NL=en_US
Command-line arguments: -os win32 -ws win32 -arch x86 -feature com.sap.java.ide C:\j2sdk\bin\javaw.exe
-Xmx512m
-Xms128m
-XX:PermSize=32m
-XX:MaxPermSize=128m
-DallUserDir='C:\Documents and Settings\All Users\Application Data'
-cp C:\Program Files\SAP\IDE\IDE70\eclipse\SapStartup.jar com.sap.ide.eclipse.startup.Main
-os win32
-ws win32
-arch x86
-feature com.sap.java.ide
-showsplash C:\Program Files\SAP\IDE\IDE70\eclipse\SapIde.exe -showsplash 600 -data C:\Documents and Settings\rajabhog\Documents\SAP\workspace -install file:C:/Program Files/SAP/IDE/IDE70/eclipse/
!ENTRY Startup 1 0 Nov 08, 2006 19:02:46.730
!MESSAGE Sap NetWeaver Developer Studio - Unknown Sap Internal Installation
!SESSION -
!ENTRY org.eclipse.core.launcher 4 0 Nov 08, 2006 19:03:03.734
!MESSAGE Exception launching the Eclipse Platform:
!STACK
java.lang.reflect.InvocationTargetException
at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:39)
at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
at java.lang.reflect.Method.invoke(Method.java:324)
at com.sap.ide.eclipse.startup.Main.basicRun(Main.java:291)
at com.sap.ide.eclipse.startup.Main.run(Main.java:789)
at com.sap.ide.eclipse.startup.Main.main(Main.java:607)
Caused by: java.lang.reflect.InvocationTargetException
at org.eclipse.core.internal.boot.InternalBootLoader.run(InternalBootLoader.java:861)
at org.eclipse.core.boot.BootLoader.run(BootLoader.java:461)
... 7 more
Caused by: org.eclipse.swt.SWTError: Item not added
at org.eclipse.swt.SWT.error(SWT.java:2356)
at org.eclipse.swt.SWT.error(SWT.java:2260)
at org.eclipse.swt.widgets.Widget.error(Widget.java:385)
at org.eclipse.swt.widgets.Menu.createItem(Menu.java:464)
at org.eclipse.swt.widgets.MenuItem.<init>(MenuItem.java:118)
at org.eclipse.jface.action.Separator.fill(Separator.java:48)
at org.eclipse.jface.action.MenuManager.update(MenuManager.java:555)
at org.eclipse.jface.action.MenuManager.update(MenuManager.java:456)
at org.eclipse.jface.action.MenuManager.fill(MenuManager.java:209)
at org.eclipse.jface.action.MenuManager.update(MenuManager.java:555)
at org.eclipse.jface.action.MenuManager.update(MenuManager.java:456)
at org.eclipse.jface.action.MenuManager.createMenuBar(MenuManager.java:146)
at org.eclipse.jface.window.ApplicationWindow.configureShell(ApplicationWindow.java:244)
at org.eclipse.ui.internal.WorkbenchWindow.configureShell(WorkbenchWindow.java:578)
at org.eclipse.jface.window.Window.createShell(Window.java:350)
at org.eclipse.jface.window.Window.create(Window.java:301)
at org.eclipse.ui.internal.Workbench.restoreState(Workbench.java:1258)
at org.eclipse.ui.internal.Workbench.access$10(Workbench.java:1223)
at org.eclipse.ui.internal.Workbench$12.run(Workbench.java:1141)
at org.eclipse.core.internal.runtime.InternalPlatform.run(InternalPlatform.java:1006)
at org.eclipse.core.runtime.Platform.run(Platform.java:413)
at org.eclipse.ui.internal.Workbench.openPreviousWorkbenchState(Workbench.java:1093)
at org.eclipse.ui.internal.Workbench.init(Workbench.java:870)
at org.eclipse.ui.internal.Workbench.run(Workbench.java:1373)
at com.tssap.util.startup.WBLauncher.run(WBLauncher.java:79)
at org.eclipse.core.internal.boot.InternalBootLoader.run(InternalBootLoader.java:858)
... 8 more
Please help me out...
As I have to fix this issue as early as possible.
Thanks & Regards,
RajPost your question in the SAP NetWeaver Technology Platform. It don't think it's JDI related...
-
IP mobility solution for a Data Centers
Hello guys
Please give me an advice.
Now I try to work out a networking solution for a two geo separated data centers (DCs).
Both the data centers will contain a virtualised server infrastructure (VMware).
Now the main design problem is to choose good solution for IP mobility and for the DCs interconnect. We need to have an ability of moving a VM machines both for maintanance and for disaster recovery between the DCs. And users must seamlessly without any advanced knowledge about routing be connected to the VM machines that were moved. For now the users work in 1100 different offices around the Ukraine country.
Yes I know a little about Cisco OTV, RHI and LISP solutions. But all this solutions require the top level switches and routers like Nexus 7000 and Cat 6500. And they are very costly.
Is there cheaper solution for the IP Mobility?
Maybe the NHRP protocol that is a part of the DMVPN could be a good solution?
Are there any features in NHRP or in other protocol for monitoring the health of a VM machine, customising and propagation the routing info in case of VM machine motion?
Thank you for help.Hi Lavanya,
Required data from a legacy system(generate data only in the form of flat files)to SAP R3 as FB01 journals - use BDC for this thing because it will be better for large source files.
the output file should be generated periodically(daily,weekly,fortnightly etc ) - if this output file contains acknowledgment for the data uploaded by the above process, create a ABAP report for it and schedule it..........but if this output contains some other IDOC data which you need to send as a file to a third-party system, then go for SAP XI provided the IDOC data is not too large... but if the IDOC size is huge, then just create a ABAP report for outputting data to a file on application server and FTP the file to third-party system.
Regards,
Rajeev Gupta
Maybe you are looking for
-
Hello all.. need help badly! Was in the process of adding blackberry desktop to a new computer (Windows 8); program went in fine but the Playbook was still connected and now it says that the playbook is not finished downloading its program and does n
-
ITunes Error Message when attempting to sync iPod
when I try to sync my iPod with iTunes I get the message "the software required for communicating with the iPod is not installed correctly. Please reinstall iTunes to install the iPods software." I have uninstalled and reinstalled iTunes 2 or more ti
-
hii, how can i view list of released PO?
-
My 4th gen ipod touch won't connect to the App Store after I updated to ios6.0. It just gives me a blank screen no message or anything.
-
Hello and greetings from Poland. Im new user and i have big problem on start. I have Sales Order and Delivery (closed by mistake) without A/R Invoice. Then the user created Returns ( product and the amount the same as on Delivery but he didnt use co