Creating In-Band management

Good morning all, I have to fix our in-band management configuration since we can't go with out-of-band at this time.
Has anyone come accross a good document that can be used for planning?
I have googled around but nothing yet.
I haven't tried the learning network just yet.
ej

Make sure the mapping to Access Group has not been deleted.
Use the command /opt/SUNWsefms/bin/lsscs list -a array mappingYou must see samething like
Volume:Access  LUN: 31mapped.via mapped.via.default.groupmapped.target.type mapped.via.default.group  Permission: Read Only
...If you don't see this recreate mapping
/opt/SUNWsefms/bin/lsscs  map -a array -l 31 volume Accessand restart agent
/etc/init.d/SMagent start

Similar Messages

  • Question about creating Certificates for Out of Band management

    I would like to use out of band management for supporting clients in remote offices.  I am following the instructions at http://technet.microsoft.com/en-us/library/230dfec0-bddb-4429-a5db-30020e881f1e#BKMK_AMT2008_cm2012 in the "Deploying Certificates
    for AMT" section.  It says:
    If you cannot complete steps 18 or 19, check that you are using the Enterprise Edition of Windows Server 2008. Although you can configure templates with Windows Server Standard Edition and Certificate Services, you cannot deploy certificates using modified
    certificate templates unless you are using the Enterprise Edition of Windows Server 2008.
    My Certificate Authority server is Server 2008R2 Standard.  When I right click on Certificate Templates -> New -> Certificate Template to Issue, I do not see the ConfigMgr AMT Provisioning and ConfigMgr AMT Web Server Certificates.  I know
    the box says 2008 Standard isn't supported, but I am using 2008R2 Standard, not 2008.  Why am I not able to see either certificate.  If it is because I am using the Standard Edition, than how can I create the certificates needed?  Upgrading
    to Enterprise is not an available solution (cost reasons).  Does this mean that OOB management certificate creation is not supported on Server 2008R2 Standard, and so I will not be able to use ConfigMgr 2012 SP1 for out of band management because I am
    unable to generate the required certificates?

    Yes, I know this is an old post, but I’m trying to clean them up. Did you solve this problem, if so what was the solution?
    In order to use the cert template, you must use an Enterprise version of Windows. Only the Enterprise (or datacenter) version have the right version of the Certificate server.
    Garth Jones | My blogs: Enhansoft and
    Old Blog site | Twitter:
    @GarthMJ

  • In band management - how

    Hello,
    We have a dual fabric SAN spanning two locations.
    All directors are MDS9513
    Today we had a short outage of the LAN on the remote site.
    Directors at the remote site could not be accessed via Fabric Manager or CLI.
    I was in the believe that our SAN was configured with <in band> management and that the SNMP traffic then goes through the FC ISL's for remote access.
    I read in the CLI fundamentals manual that <out of band> and <in band> management are setup in VSAN 1 during installation at the console prompts.
    How can I check that <in band> management is properly setup?
    Apparantly it does not work now and a new/proper install is required (@ next firmware upgrade - reboot)
    Rgds,
    Ivy

    I performed the following steps on each of our switches in our environment to have a back-end network in case of a LAN outage:
    The way I've done this is create interfaces on VSAN1 on all of our switches
    interface vsan 1
         ip address 192.168.150.X
         no shut
    Then would create a default route for that network:
    ip route 192.168.150.0 255.255.255.0 interface vsan 1
    I'm not sure the above step was necessary because I then would turn on ip routing:
    ip routing
    So as long as vsan 1 in the case is merged between the switches you need to get to you should be able to telnet from one switch to another at anytime. You can also use fabric manager and see the switches using this back-end network.
    Just in case:
    Should probably add that 192.168.150.0 network isn't being used anywhere else in our environment.
    Message was edited by: Robert Hersh

  • AMT Computer Object Creation in Out of Band Management

    Just configured our Out of Band Management / AMT settings and we're getting all our AMT systems provisioned successfully. I've noticed that now, in SCCM 2012, the AMT object that gets created are Computer objects in AD. Their objectCategory is
    CN=Computer,CN=Schema,CN=Configuration,DC=mydomain,DC=com
    Back in the SCCM 2007 days, They were Person objects in AD. We still have some in AD.
    CN=Person,CN=Schema,CN=Configuration,DC=mydomain,DC=com
    Is this the default setting or do I have the option to change it?
    Orange County District Attorney

    Since no one has answer this post, I recommend opening  a support case with CSS as they can work with you to solve this problem.
    Garth Jones | My blogs: Enhansoft and
    Old Blog site | Twitter:
    @GarthMJ

  • How to create the bands

    Hi,
    Can any one help me out in creating the bands in Webi (for example : Report of aging and its performance, so some measures need to be analysed against the age bands like 10-20,20-30,30-40....so on).
    Is it possible to define certain bands in the BO XI 3.1 Webi.
    Regards,
    Siva

    You can define bands in Web-I with the help of If Else logic and Context operators (If required). Here is one of the formula
    that I am using in my reports:
    =If(([Measure] ForEach ([Dim]))>=80) Then ">80%" ElseIf(([Measure] ForEach ([Dim]) Between(70;80))) Then "70% - 80%" ElseIf
    (([Measure] ForEach ([Dim]) Between(60;70))) Then "60% - 70%" ElseIf(([Measure] ForEach ([Dim]) Between(50;60)))
    Then "50% - 60%" Else "<50%"
    You can remove the For Each ([Dim]) from the formula if you want to work with default context. Else use "In", "For Each" and
    "For All" depending on the requirement.
    Regards,
    Rohit
    Edited by: rohit12 on Jun 15, 2010 8:10 AM

  • Can't log in as a user created in Workgroup Manager

    I am a little confused about users created in Workgroup Manager.
    I have created an account with all the proper permissions to log in etc. Their home directory is listed as afp://home/Users (home is the name of the server). The directory for the user I am trying to log in as doesn't exist yet.
    When I try to log into the server "home" with this newly created user, I get the vibrating window that indicates the log in failed.
    I am used to windows and AD where I would create a user in AD and then use something like \\domain\user to log in to the machine as that user. If i wanted to create a local user on that machine, I could do that too and then log in as \\machine\user to get the local user.
    Are Workgroup Manager created users like AD users? Can I use them to log into any machine on the network hooked up to the SL server machine? In this case I want to log into the SL Server machine with this user.
    Thanks for any insight
    Greg

    There is only one root user, so saying "a root user" doesn't make sense. What you mean is an admin user, and it looks like your account has somehow manage to lose its admin privileges.
    Follow the instructions in I lost my admin user and you should get them back.
    Note that in this User Tip, 'youruser' is a placeholder. You are supposed to substitute the short name of your account wherever it appears.

  • I am trying to import standard midi file that I created in Band in a Box into Logic Pro 9.  I can not get all the track to play with internal instrument sounds... only the piano track.  how can I get the others to play... drums, bass etc????   Help

    I am trying to import standard midi file that I created in Band in a Box into Logic Pro 9.  I can not get all the track to play with internal instrument sounds... only the piano track.  how can I get the others to play... drums, bass etc????   Help

    Don't drag the midi into an open Logic project. The tracks won't set up correctly.
    'Open' the midi file with Logic as if it were a Logic project. Then all the tracks will be set up so you can start editing them and applying better saved sounds and instruments, but you'll be at a starting place where you can hear what's going on.

  • Managed Property in Refinement - why not use the automatically-created site column managed property

    Hi,
    I read that although SharePoint 2013 automatically creates managed property for site column (OWS_Q_TEXT_COLUMNNAME) - in the refinement i should use a managed property and map to the ows_columnname. why?
    what's the difefrence?
    what is best - to create a new managed property (and set it as refinable) or use the OOB Refinementstring0, Refinementstring1 etc.)?
    keren tsur

    You are probably talking about this blog post.
    http://blogs.technet.com/b/tothesharepoint/archive/2013/11/11/how-to-add-refiners-to-your-search-results-page-for-sharepoint-2013.aspx
    The reason you want to use the ows_columnname crawled property is because it is of the correct data type. The other is always text. If the site column is a date or a decimal then using the OWS_Q_TEXT... crawled property,will cause the refiner not to display
    the appropriate control, for example a slider control for a date type refiner.
    http://sharepointfieldnotes.blogspot.com/2013/05/understanding-and-getting-sharepoint.html
    Blog | SharePoint Field Notes Dev Tools |
    SPFastDeploy | SPRemoteAPIExplorer

  • EPMA Batch Client - Can I launch business rules created in Calc Manager?

    I'm currently on a project where we have implemented an EPMA Planning app (v 11.1.1.2), and we need to schedule business rules to run in batch. In the past, I used the command line launcher to perform this task. Unfortunately, the command line launcher is really a part of EAS, so it would appear that I cannot use this method to launch a rule created in Calc Manager. Is this correct?
    It looks like my other option is to use the EPMA Batch Client. In looking at the "Execute" command in the documentation, it doesn't reference the ability to run a business rule. The docs are fairly limited, so I'm wondering if I really CAN launch a business rule from here.
    Has anyone scheduled a business rule (created in Calc Manager) to run in batch? If so, what method did you use? If all else fails, I can create a calc script and run it from MaxL, but I'd rather not have multiple versions of the code floating around.
    Thanks!
    - Jake

    Hi Jake,
    One of the known issues in 11.1.1.3 is :-
    You cannot launch a business ruleset with runtime prompts from the Planning command line launch (7205464).
    Whether this means you can't run calc manager BR's from command line I am not sure.
    There is no documentation in this area so I assume it can't be done yet.
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • In-Band Management Software for StorageTek 2530

    I'm trying to install the software needed for in-band management for a StorageTek 2530 SAS Array. Page 83 of Sun StorageTek Common Array Manager Software Installation Guide, 820-2934-10, list the following needed for Linux x86_64
    Linux:
    &#9632; SMagent-LINUX-90.00.A0.06-1.ia64.rpm
    &#9632; SMruntime-LINUX-90.10.A0.02-1.ia64.rpm
    I have downloaded SMagent-LINUX-90.00.A0.06-1.ppc64.rpm on the Sun website but I cannot find SMruntime-LINUX-90.10.A0.02-1.ia64.rpm
    Does anyone know where I can download it from?
    Thanks

    Download Sun StorageTek Common Array Manager In-Band Proxy Agent Packages 6.0.0 for Red Hat Enterprise Linux 4, English
    Download Information and Files
         Get the latest Java Runtime Environment to use Sun Download Manager
    Internet Explorer Users: Check the top of this page for a "Java(TM) Web Start ActiveX Control" message in the information bar. If it appears, click it to finish detecting your Java version.
    We were unable to detect a recent version of Java Runtime Environment (JRE) on your system. With the latest JRE, you can automatically download, install, and run Sun Download Manager (SDM) directly from this page. We highly recommend SDM to easily manage your downloads (pause, resume, restart, verify, and more). Visit java.com for the latest JRE.
    Sun StorageTek Common Array Manager 6.0 Documentation
    Sun StorageTek 2500 Arrays Documentation
    Sun StorageTek 6140 and 6540 Arrays Documentation
    Instructions: Select the files you want, then click the "Download Selected with Sun Download Manager" (SDM) button below to automatically install and use SDM (learn more). Alternately, click directly on file names to download with your browser. (Use of SDM is recommended but not required.)
    Your download should start automatically.
    If not, click the file link below.
    Sun Download Manager(SDM) installation should begin automatically.
    Once it is running, click Start to download the product.
    If your system does not support SDM, click the file link below to download.
    (For help with SDM, see SDM Troubleshooting.)
    Required Files Select All      File Description and Name      Size
         CAM 6.0 In-Band Management Installation Document
    InBand_Installation.html      25.95 KB
         CAM 6.0 In-Band Management Release Notes
    RELEASE_NOTES.txt      7.81 KB
    Optional Files Select All      File Description and Name      Size
         Agent for Linux running on ia64 (Intel Itanium) processors
    SMagent-LINUX-90.00.A0.06-1.ia64.rpm      0.45 MB
         Agent for Solaris SPARC platforms
    SMagent-SOL-90.00.00.06.pkg      1.77 MB
         Runtime package for Solaris SPARC platforms
    SMruntime-SOL-10.10.02.00.pkg      95.59 MB
         Agent for Linux running on Power PC 64-bit processors
    SMagent-LINUX-90.00.A0.06-1.ppc64.rpm      0.45 MB
         Agent for Linux running on 386 platform (AMD & Intel)
    SMagent-LINUX-90.00.A0.06-1.i386.rpm      0.45 MB

  • Use of SQL fetchlet to create a custom management plug-in

    Hi,
    I would appreciate if you anyone could help me out on this:
    I need to fetch some data from EMF tables and create a custom Management plug-in in OEM so that it can be monitored from OEM itself. For getting the data from database table i am using SQL fetchlet coz it provides the facility to use SQL statement in it. Following is the code i have developed in target-type.xml file.
    <TargetMetadata META_VER="1.0" TYPE="emf_filer">
    <Display>
    <Label NLSID="emf_filer">Error Management Filer</Label>
    </Display>
    <Metric NAME="emf_filer" TYPE="TABLE">
    <Display>
    <Label NLSID="emf_filer_resp">Response</Label>
    </Display>
    <TableDescriptor>
    <!-- <ColumnDescriptor NAME="tcpPing" TYPE="NUMBER" >
    <Display>
    <Label NLSID="netapp_filer_resp_tcpPing">TCP Ping, Milliseconds</Label>
    </Display>
    </ColumnDescriptor> -->
    <ColumnDescriptor NAME="Status" TYPE="NUMBER" >
    <Display>
    <Label NLSID="emf_filer_resp_status">Status</Label>
    </Display>
    </ColumnDescriptor>
    <ColumnDescriptor NAME="PROGRAM_NAME" TYPE="STRING" >
    <Display>
    <Label NLSID="PROGRAM_NAME">Program Name</Label>
    </Display>
    </ColumnDescriptor>
    <ColumnDescriptor NAME="PROGRAM_TYPE" TYPE="STRING" >
    <Display>
    <Label NLSID="PROGRAM_TYPE">Program Type</Label>
    </Display>
    </ColumnDescriptor>
    <ColumnDescriptor NAME="RICEW_ID" TYPE="STRING" >
    <Display>
    <Label NLSID="RICEW_ID">Rice Id</Label>
    </Display>
    </ColumnDescriptor>
    <ColumnDescriptor NAME="Request_id" TYPE="NUMBER" IS_KEY="TRUE" >
    <Display>
    <Label NLSID="Request_id">Request Id</Label>
    </Display>
    </ColumnDescriptor>
    <ColumnDescriptor NAME="EBIZ_INSTANCE_NAME " TYPE="STRING" >
    <Display>
    <Label NLSID="EBIZ_INSTANCE_NAME">Instance Name</Label>
    </Display>
    </ColumnDescriptor>
    </TableDescriptor>
    <QueryDescriptor FETCHLET_ID="SQL">
    <Property NAME="MachineName" SCOPE="INSTANCE">MachineName</Property>
    <Property NAME="Port" SCOPE="INSTANCE">Port</Property>
    <Property NAME="SID" SCOPE="INSTANCE">SID</Property>
    <Property NAME="UserName" SCOPE="UserName">apps</Property>
    <Property NAME="password" SCOPE="password">password</Property>
    <Property NAME="ServiceName" SCOPE="INSTANCE">ServiceName</Property>
    <Property NAME="STATEMENT" SCOPE="INSTANCE">
    BEGIN
    SELECT PROGRAM_NAME, PROGRAM_TYPE,
    RICEW_ID,REQUEST_ID, EBIZ_INSTANCE_NAME FROM XX_EMF_MESSAGE_HEADER WHERE STATUS = 'ERROR' AND RICEW_ID = 'INT-DL019';
    END;
    </Property>
    <!-- <Property NAME="SQLINPARAM1" SCOPE="ENV">HOSTNAME</Property>
    <Property NAME="SQLOUTPARAMPOS" SCOPE="GLOBAL">2</Property>
    <Property NAME="SQLOUTPARAMTYPE" SCOPE="GLOBAL">SQL_CURSOR</Property>-->
    <Property NAME="NUMROWS" SCOPE="GLOBAL">40
    </Property>
    </QueryDescriptor>
    <ExecutionDescriptor>
    <GetTable NAME="emf_filer"/>
    <GetView NAME="emf_View" FROM_TABLE="emf_filer">
    <Column NAME="PROGRAM_NAME"/>
    <Column NAME="PROGRAM_TYPE"/>
    <Column NAME="RICEW_ID"/>
    <Column NAME="REQUEST_ID"/>
    <Column NAME="EBIZ_INSTANCE_NAME"/>
    <Filter COLUMN_NAME="REQUEST_ID" OPERATOR="GT">0</Filter>
    </GetView>
    </ExecutionDescriptor>
    <InstanceProperties>
    <InstanceProperty NAME="UserName" CREDENTIAL="TRUE" OPTIONAL="FALSE" NEED_REENTER="FALSE" HIDE_ENTRY="FALSE">
    <Display>
    <Label NLSID="UserName_emf">Username</Label>
    </Display>
    </InstanceProperty>
    <InstanceProperty NAME="password" CREDENTIAL="TRUE" OPTIONAL="FALSE" NEED_REENTER="TRUE">
    <Display>
    <Label NLSID="password_emf">Password</Label>
    </Display>
    </InstanceProperty>
    <InstanceProperty NAME="MachineName" CREDENTIAL="FALSE" OPTIONAL="FALSE">
    <Display>
    <Label NLSID="MachineName_emf">Listener Machine Name</Label>
    </Display>
    </InstanceProperty>
    <InstanceProperty NAME="Port" CREDENTIAL="FAL
    My doubt here is:
    As per Oracle it is importent to use response matrics with status column. How can i accomodate Response matrics with this code. what will be the columns except Status that i need to mention? if i use just one matrics i.e response then what will i use in in FROM clause in ExecutionDescriptor [<GetView NAME="emf_View" FROM_TABLE="emf_filer">]? i wuld appreciate if anyone could clarify my issues.
    Thanks for your help.
    Regards,
    AS

    That is what i am trying to ask..as i will b using 2 dfifferent matrics so i will have to use 2 diffrent QueryDescriptors one for Response matric and one for other one. Now following QueryDescriptor will be added in other(Not Response) matric then what should i add in QueryDescriptor in Response matric?
    Query Descriptor for matric other than "Reposnse":
    QueryDescriptor FETCHLET_ID="SQL">
         <Property NAME="MachineName" SCOPE="INSTANCE">MachineName</Property>
         <Property NAME="Port" SCOPE="INSTANCE">Port</Property>
         <Property NAME="SID" SCOPE="INSTANCE">SID</Property>
         <Property NAME="UserName" SCOPE="UserName">UserName</Property>
         <Property NAME="password" SCOPE="password">password</Property>
         <Property NAME="ServiceName" SCOPE="INSTANCE">ServiceName</Property>
         <Property NAME="STATEMENT" SCOPE="GLOBAL">
              SELECT PROGRAM_NAME,
                             PROGRAM_TYPE,
                             RICEW_ID,REQUEST_ID,
                             EBIZ_INSTANCE_NAME
              FROM XX_EMF_MESSAGE_HEADER WHERE STATUS = 'ERROR' AND RICEW_ID = 'INT-DL019';
              </Property>
    </QueryDescriptor>
    what should be the QueryDescriptor for Response matric?? Will it be same or different?
    Thanks for your help.
    Regards,
    AS
    Edited by: user9959418 on Oct 31, 2008 1:10 PM

  • Setting up in-band management

    The problem I'm encountering is very similar to the following post " [In-Band Management configuration for 2530 array from T5120 on Solaris 10|http://forums.sun.com/thread.jspa?forumID=831&threadID=5338514] "
    Running the command java -classpath /opt/SMgr/agent/SMagent.jar devmgr.versioned.agent.DeviceIdentifier does not return any LUNs with Volume Access.
    SANtricity Storage Manager Devices, Version 90.00.00.06
    Built Wed May 23 09:02:26 CDT 2007
    Copyright (C) 1999-2007 LSI Logic Corporation. All rights reserved.
    /dev/rdsk/c8t600A0B800048A6A80000102D48A98B38d0s2 [Storage Array 6140, Volume groups1, LUN 1, Volume ID <600a0b800048a6a80000102d48a98b38>, Preferred Path (Controller-A): In Use]
    /dev/rdsk/c8t600A0B80004898B8000007B948A98A5Cd0s2 [Storage Array 6140, Volume homes1, LUN 0, Volume ID <600a0b80004898b8000007b948a98a5c>, Preferred Path (Controller-B): In Use]
    I'm worried about using lsscs to change it to say Access since groups1 and homes1 correspond to our two main storage pools(We are using zfs). Will I be unable to use in-band management? Or will I be able to change it with out causing any downtime?
    Thanks,
    David

    I have the same problem (no Volume Access LUN).
    Can somebody help?

  • In-Band Management configuration for f5100 array from T5440 on Solaris 10

    Hi All,
    I am trying to configure in-band management for storagetek array Sun Storage F5100 from T5440 server on Solaris 10.
    OS Installed on the server: Solaris 10 10/09
    Hardware : T5440
    Array : Sun Storage F5100
    Sun Storage F5100 have 20 FMODs which can see from format output. But In-Band management don't work, i want to manage it by CAM.
    /dev/rdsk/c2t0d0s2
    /dev/rdsk/c2t1d0s2
    /dev/rdsk/c2t2d0s2
    /dev/rdsk/c2t3d0s2
    /dev/rdsk/c2t4d0s2
    /dev/rdsk/c2t5d0s2
    /dev/rdsk/c2t6d0s2
    /dev/rdsk/c2t7d0s2
    /dev/rdsk/c2t8d0s2
    /dev/rdsk/c3t0d0s2
    /dev/rdsk/c3t1d0s2
    /dev/rdsk/c3t2d0s2
    /dev/rdsk/c3t3d0s2
    /dev/rdsk/c3t4d0s2
    /dev/rdsk/c3t5d0s2
    /dev/rdsk/c3t6d0s2
    /dev/rdsk/c3t7d0s2
    /dev/rdsk/c3t8d0s2
    Below are the packages i installed:
    host_sw_solaris_6.6.0.11
    SMagent-SOL-90.01.02.05.pkg
    SMruntime-SOL-90.60.02.01.pkg
    once after i installed the above packages i am getting below error
    SANtricity Storage Manager Agent, Version 90.01.02.05
    Built Wed May 06 06:21:07 CDT 2009
    Copyright 2009 Sun Microsystems Inc. All rights reserved. Use is subject to license agreement.
    Checking device /dev/rdsk/c0t2d0s2 : Skipping
    Checking device /dev/rdsk/c0t3d0s2 : Skipping
    Checking device /dev/rdsk/c2t0d0s2 : Skipping
    Checking device /dev/rdsk/c2t1d0s2 : Skipping
    Checking device /dev/rdsk/c2t2d0s2 : Skipping
    Checking device /dev/rdsk/c2t3d0s2 : Skipping
    Checking device /dev/rdsk/c2t4d0s2 : Skipping
    Checking device /dev/rdsk/c2t5d0s2 : Skipping
    Checking device /dev/rdsk/c2t6d0s2 : Skipping
    Checking device /dev/rdsk/c2t7d0s2 : Skipping
    Checking device /dev/rdsk/c2t8d0s2 : Skipping
    Checking device /dev/rdsk/c3t0d0s2 : Skipping
    Checking device /dev/rdsk/c3t1d0s2 : Skipping
    Checking device /dev/rdsk/c3t2d0s2 : Skipping
    Checking device /dev/rdsk/c3t3d0s2 : Skipping
    Checking device /dev/rdsk/c3t4d0s2 : Skipping
    Checking device /dev/rdsk/c3t5d0s2 : Skipping
    Checking device /dev/rdsk/c3t6d0s2 : Skipping
    Checking device /dev/rdsk/c3t7d0s2 : Skipping
    Checking device /dev/rdsk/c3t8d0s2 : Skipping
    The SMagent service attempted to start but terminated. Possible causes include: [1] The access volume is disabled in NVSRAM. [2] No controllers with compatible firmware were found. [3] The default logical unit number (LUN) assigned to the access volume (typically 7 or 31) is not in the range supported by the host or is already in use by the host for another device. See your storage management documentation for more details.
    Jul 23 13:56:47 sol10 SMagent: The SMagent service attempted to start but terminated. Possible causes include: [1] The access volume is disabled in NVSRAM. [2] No controllers with compatible firmware were found. [3] The default logical unit number (LUN) assigned to the access volume (typically 7 or 31) is not in the range supported by the host or is already in use by the host for another device. See your storage management documentation for more details.
    As per sun documentation i ran the below commands, but still i am getting above error.
    # setenv LD_LIBRARY_PATH /opt/SMgr/agent
    # java -classpath /opt/SMgr/agent/SMagent.jar devmgr.versioned.agent.DeviceIdentifier | grep "Volume Access"
    But any output with above commands.
    Any help would be really help ful.
    Thanks,
    gebilong

    Make sure the mapping to Access Group has not been deleted.
    Use the command /opt/SUNWsefms/bin/lsscs list -a array mappingYou must see samething like
    Volume:Access  LUN: 31mapped.via mapped.via.default.groupmapped.target.type mapped.via.default.group  Permission: Read Only
    ...If you don't see this recreate mapping
    /opt/SUNWsefms/bin/lsscs  map -a array -l 31 volume Accessand restart agent
    /etc/init.d/SMagent start

  • In-Band Management configuration for 2530 array from T5120 on Solaris 10

    Hi All,
    I am trying to configure in-band management for storagetek array 2530 from T5120 server on Solaris 10. I could able to connect the array from CAM software and it is showing as out-of-band. I can able to change the array name and IP address also. But when i try to configure In-Band Management i am having problems.
    OS Installed on the server: Solaris 10 5/08
    Hardware : T5120
    Array : Storage Tek 2530
    Below are the packages i installed:
    SMagent-SOL-90[1].00.00.06.pkg
    SMruntime-SOL-10[1].10.02.00.pkg
    once after i installed the above packages i am getting below error
    "SANtricity Storage Array Host Agent, Version 90.00.00.06
    Built Wed May 23 09:02:26 CDT 2007
    Copyright (C) 1999-2007 LSI Logic Corporation. All rights reserved.
    Checking device /dev/rdsk/c1t0d0s2 : Skipping
    The SMagent service attempted to start but terminated. Possible causes include: [1] The access volume is disabled in NVSRAM. [2] No controllers with compatible firmware were found. [3] The default logical unit number (LUN) assigned to the access volume (typically 7 or 31) is not in the range supported by the host or is already in use by the host for another device. See your storage management documentation for more details.
    The Host Context Agent did NOT start because 0 controllers were found.
    Oct 9 19:51:10 proto-hd1 SMagent: The SMagent service attempted to start but terminated. Possible causes include: [1] The access volume is disabled in NVSRAM. [2] No controllers with compatible firmware were found. [3] The default logical unit number (LUN) assigned to the access volume (typically 7 or 31) is not in the range supported by the host or is already in use by the host for another device. See your storage management documentation for more details.
    Oct 9 19:51:10 proto-hd1 SMagent: The Host Context Agent did NOT start because 0 controllers were found."
    As per sun documentation i ran the below commands, but still i am getting above error.
    # setenv LD_LIBRARY_PATH /opt/SMgr/agent
    # java -classpath /opt/SMgr/agent/SMagent.jar devmgr.versioned.agent.DeviceIdentifier | grep "Volume Access"
    Any help would be really help ful.
    Thanks,
    Raja

    Make sure the mapping to Access Group has not been deleted.
    Use the command /opt/SUNWsefms/bin/lsscs list -a array mappingYou must see samething like
    Volume:Access  LUN: 31mapped.via mapped.via.default.groupmapped.target.type mapped.via.default.group  Permission: Read Only
    ...If you don't see this recreate mapping
    /opt/SUNWsefms/bin/lsscs  map -a array -l 31 volume Accessand restart agent
    /etc/init.d/SMagent start

  • Create a dictionary managed tablespace  error.

    When I use the following script to create a tablespace.
    create tablespace DATA01
    datafile 'c:\oracle\oradata\orawin2k\U04\data01.dbf' size 2M
    EXTENT MANAGEMENT DICTIONARY;
    But the oracle return this error.
    ORA-12913: Cannot create dictionary managed table.
    My Oracle Server is 9i Release in Window 2000.
    Does any one know why? Please Help.

    Check with docu: Oracle9i Database Error Messages
    Error means "An attempt was made to create a dictionary managed tablespace in a database whose SYSTEM tablespace is locally managed."
    So you can't create any DMTs.

Maybe you are looking for

  • What is the best solution to monitor Exchange server was not work normally

    Hi everyone , I have a problem about how to monitor (or detect) the status of Exchange server , so that I can inform our users to change the mail server destination they will connect. Can I just test the connection status of SMTP, POP3 , IMAP3 ? and

  • WHERE CAN I GET A DIAGRAM OF THE BACK OF MY IMAC

    Where can I find  a diagram of the back of my Imac

  • Fan on stacks does not display

    I've used stacks before and I hadn't had this problem happen to me until just recently. I made a stack and when I right click and ctrl to view the preferences to change from grid to fan, fan is not even an option it only shows grid, list and automati

  • SAP Crystal Runtime 13 - free to use?

    Hi, We have a few third party systems that use SAP Crystal Runtime. What we have currently is version XI. Just wanted to find out that if its free to upgrade to 13? Not aware of any licensing agreements we have with SAP given that we don't use any of

  • Can't get flash plugin to work

    I am running IE 6 and it has been working fine until just a few days ago. Then I noticed I was unable to access webpages that have flash video on the homepage (i.e. myspace) The page would quit loading when it was trying to load the flash video. I we