Error 65550: CRio 9802

Hi everybody,
I was running example "NI 9802 RT Access" from a 9074 writing to a 9802 but I got the following error: 
Error 65550 occurred at cRio-91XX_MountSdDrive.vi
Possible reason(s):
CompactRIO: A problem was found in the file system. Remove the SD card and run CHKDSK. 
Running CHKDSK returns no problems. Any idea what's causing this error?
Thanks a lot. 
Solved!
Go to Solution.

Dhasa
This is a known issue for the NI RIO 3.0.1 driver, you can fix it by upgrading the NI RIO 3.1
Please repost if that does not fix it.
-Hunter

Similar Messages

  • CRIO 9802 Error 65000

    Hi all,
    i tried the LabVIEW example "NI 9802 RT Access (Host)", with which i want to mount one SD card. I everytime get the attached error message. I already used chkdsk to correct the SD card and there are no errors on it. It's no problem to write file from the FPGA, but to mount from RT result's in this error.
    I use LabVIEW 8.6. NI RIO 3.0.1 is installed on the cRIO.
    Can someone guide me to a solution.
    Thanks.
    Alex
    Message Edited by -_ALEX_- on 02-06-2009 10:02 AM
    Solved!
    Go to Solution.
    Attachments:
    Error65000.PNG ‏8 KB

    Hi John,
    thanks for letting me know that the new NI Rio is available.
    I installed the new driver, but unfortunately a got a new Problem. It is possible to Mount and Unmount the SD Card, but i can’t ftp to it.
    I tried to connect via Microsoft IE, and received following message:
    Does anybody have an idea why?
    Thanks
    Message Edited by -_ALEX_- on 02-20-2009 11:13 AM
    Attachments:
    mount.JPG ‏25 KB

  • Shared Variable Initial value not licenced error with cRIO

    Hello Everyone,
    I've a project that will be deploed on cRIO. This project was created on a different machine and didn't have any error regarding the shared variables. when I transfered the project to the computer connected to the cRIO, I have this error with all shared variable. The error message says that:
    1. Initial Values: Not Licenced or can't be edited outside of LabVIEW.
    2. Logging: Not Licenced or can't be edited outside of LabVIEW.
    attached are two images for the error i have.
    Can I have help with this issue?
    Thanks in advance
    Attachments:
    1.png ‏134 KB
    2.png ‏142 KB

    Good day,
    Sounds like you are using the DSC module features on your code and you forgot to activate the runtime system on that machine. If you have access to the NI License Manager, please check the status of the license.
    We need an active license for the second message but, for the first one you can try to program your own initial values for all of your network-published shared variables by initializing whenever the PC is started. During the initialization portion of your code, you can just write a constant value to the shared variables so the values are the same initial values every time it is run.
    Regards,
    Alejandro | Academic Program Engineer | National Instruments

  • Errors in cRIO Programs

    Hello...
            I started working on cRIO-9074 with simple program. I tried to send the image from Host VI to FPGA VI by first converting the image into 1D array. I connected this 1D array to host2target DMA FIFO write. In FPGA VI, I added some numeric to the output elements of Host2target DMA FIFO Read function. Next, I connected the resultant to Target2host DMA FIFO write function. In host VI, I am trying to display the output of Target2host DMA FIFO Read function.  I am getting some errors in both FPGA VI and Host VI. 
    Please see this simple example and let me know how to  correct them.
    Thanks
    Prashanth
    Attachments:
    HostVI.JPG ‏47 KB
    FPGAVI.JPG ‏35 KB
    projectexplorer.JPG ‏40 KB

    It is an academic project. The aim of this project is to help under graduate students know about different processors/hardware. 
    I have one doubt.  Generally, FPGAs are used for prototyping. Before doing ASIC design, they will first check the application on FPGA. But, why labview needs FPGA.
    There are two modes of operation 1.scan interface mode 2.fpga interface mode
    scan interface mode is for high speed data aquisition using FPGA I/Os but why fpga interface mode........??
    Please clarify
    Thanks
    Prashh 

  • Error code 6: Generic I/O error with cRIO TDMS

    Hi,
    I am trying to use the TDMS VIs in LabVIEW 8.6, but the open TDMS VI is giving me error code 6, the "Generic I/O error".  The file path is specified like this: "c:\data\lotsofdata.tdms".  Anyone out there have an idea of what I could do to get this working?  Please let me know if I can provide more info about the error!
    Thank you,
    Alex

    Thanks, I'll try that tomorrow.  I saw this post:
    http://forums.ni.com/ni/board/message?board.id=280&message.id=5722&requireLogin=False
    Which said to use a lowercase "c", and my c was already lowercase.
    Thank you!

  • FPGA Reset during power loss? NI 9802 Module

    We have recently started using the NI 9802 on a cRIO system. We are getting the error -65550 discussed here: http://digital.ni.com/public.nsf/allkb/BD118434E87B9732862575C8006FD7FB
    The article says that the error can be caused by the FPGA resetting while the drive was mounted. "To prevent this error from happening in the future, do not reset the
    FPGA while you have an SD card mounted, reset before you mount the card
    or after the card is unmounted." Does a power loss reset the FPGA and require you to reformat the card??? We plan to use this as a remote system and power failure is possible. We would not be able to travel hundreds of miles back to the device to reformat an SD card in the event of a power loss. This can't be right. How could they sell a module that worked like that?
    Also, does the card need to be formatted with FAT32 or FAT16?
    [will work for kudos]
    Solved!
    Go to Solution.

    I would like to submit a suggestion for the next version of this module. It would be awesome if in the rare but possible case of the crio losing power that the card did not become corrupt and you would then not need to travel all the way to the device and pull the SD cards out and reformat them with a pc before your system could be come operational. Like the ability to reformat at run-time would be a decent fail safe function. Even though you would lose all the data you had recorded onto the SD Card, wasting time and money, at least the entire system would not be fatally crippled by a simple loss of power and unexpected device reboot.
    As it stands, even with a quality power backup battery as you have suggested, the simple possibility that you could lose power and need to manually perform a format on the SD card makes this module inferior to simply plugging in a big USB drive, both in terms of reliability and storage space. The appeal to this module, even though it could only hold two 2 gig SD cards, was its apparent ruggedness and reliability over using a usb drive.
    Respectfully waiting for a new version of this module,
    Rex
    [will work for kudos]

  • Error 1335 When Installing Compact RIO Module Software 2.1.4 From Hard Drive

    I’m having issues with the installation of the CompactRIO Module Software 2.1.4.
    Initially, problems were occurring when trying to communicate with the device, as it was denying access to it from the Development PC. Various things were tried such as adding a ‘*’ to the fields and making sure 'Allow' was selected in the communication properties on LabView RT. This didn't seem to work. A post relating to our problem is here: http://forums.ni.com/ni/board/message?board.id=170​&message.id=269809&query.id=18752#M269809
    As none of this was working, we decided to format the disk on the Compact RIO and reinstall the software to it. The software downloaded from Ni.com was the CompactRIO Module Software version 2.1.4 (dated May 2007). This file was unzipped using WinZIP 9.0 (on a PC running Windows XP Pro SP2 5.1.2600) and then transferred with a USB stick to the Development PC.
    We attempted to install the file on the Development PC (running Windows 2000 SP3 5.00.2195) by running setup.exe. This started normally, but then proceeded to come up with an error message saying: ‘Error 1335. The cabinet file ‘Cabs.w1.cab’ required for this installation is corrupt and cannot be used. This could indicate a network error, an error reading from the CD-ROM, or a problem with this package.’
    Attached are screen shots of the error message that appears.
    As a result of this error, the installation could not be continued and the module software was not installed.
    What is going wrong with the installation and how can I go about sorting it out?
    Thanks very much,
    Moses
    RT target cRIO-9012, NI-RIO 2.1.3, LV 8.2, RT 8.2, FPGA 8.2, host ip 150.150.10.15, cRIO IP 150.150.10.4
    Message Edited by Mohoyt on 09-10-2007 04:03 AM
    Attachments:
    Error Message CRIO Module 2.1.4.JPG ‏36 KB

    Way,
    Thanks for the help overall, I finally worked it out. The problem was initially present in the unzipping of the original archive that had been downloaded from the NI.com website. When I had previously unzipped it, I had done so to a network drive which for some reason stopped autorun.inf and autorun.exe from functioning properly and so when I tried to install it on the Dev PC I got the aforementioned error. To overcome this problem I unzipped it to a local drive and (surprise!) there were no faults, so when installing the actual software, no errors appeared and it was installed correctly.
    This however was not the only problem, the version that had now been installed did not want to co-operate with the RIO at all, and came up with various software errors in addition to not having all of the available software modules for the RIO available to install. The solution was then to install the newest RIO software, which is very badly labelled on the NI.com website by the way (its packaged as RIO software, so if you're looking explicitly for CRIO software you've got no chance of finding it). The newest version, 2.3 (Aug 07) as opposed to the 2.1.4 (May 07) that I was previously trying, worked fine and I was able to get all the software modules installed. So for now the problem is solved!
    Thanks again for all the help.
    Cheers,
    Moses

  • Is NI-9802 memory module compatible witn NI-cRIO 9081????

    hello,
            I an working on NI-cRIO 9081 using NI-9467 GPS module and 9795 WSN gateway. Now  i want to load this data into NI-9802 memory card module, but i am getting a error code 65010 showing that you cant mount or unmount SD card on this cRIO 9081. Can somebody give me a sugestion related to this problem ?????
      i am waiting for response

    Here is an example VI that ships with LabVIEW that may help.  You can change the Write to Text File to Write to Binary File.
    Applications Engineer
    National Instruments
    Attachments:
    9802.zip ‏5 KB

  • Want to ftp to NI 9802 through cRIO 9014

    Can the cRIO 9014 access the 9802's SD memory cards directly as disks?
    If I use the cRIO 9014 as an ftp server, can I download/upload files directly to the 9802's SD memory cards from the an external computer, via ftp?
    It initially looks to me like only the FPGA, not the 9014, sees the 9802 directly, which means the answer to my questions is NO, unless there's a device driver for VxWorks.
    Does anyone know more?
    Thanks

    Hi,
    Thanks for the good information.  I was running into the same problems in my application.  I would like to make a few clarifications though.  
    First: Most of the file I/O functions available to you on the function pallet boil down to primitive file functions, so it is not necessary to restrict yourself to using only primitive file functions, one can use the Write To Spreadsheet File vi for example. 
    Second: As stated in the KB article here http://digital.ni.com/public.nsf/allkb/6BA5F76568E​CADA68625742D006A0356 a property OR method node can be used in the FPGA vi to resolve the shared resource conflict indicated by Error -65549.  So if you application already used one of the methods, it is not necessary to go out of you way to use a property node referencing the 9802.  However, if you application does not use one of the 9802 methods, using a property node that references the 9802 is the method that uses the least amount of FPGA resources to resolve the conflict. 
    I hope this helps anyone that comes across this post and has the same problems that I was having.
    I would like to thank Matt Rings, one of NI's embedded gurus and Chris Nelson my local NI sales rep for helping me out with this issue.
    Message Edited by Gravy Train on 06-09-2008 10:37 AM
    Message Edited by Gravy Train on 06-09-2008 10:37 AM

  • NI 9802 File Error 11

    Hello All!
    I encountered a problem while file logging on an SD card which is
    installed in NI 9802. There are 169 binary files already in the SD
    card, when the 170th file is to be created an error with code 11 comes
    out. Please help me to remove this error.
    Software:
    LV 8.5.1
    cRIO 2.4
    Hardware:
    cRIO 9012
    NI 9802
    Regards
    Mani 

    Brandon,
    I still have a few issues and thought that maybe you could help me out here. I have now managed to save my files in my SD card via the 9802 module using the standard RT scan engine method attached with the original post. However, I cannot find a way to download my files to my local machine. I am using the std FTP functions (please see attached) but I get the typical file not found error. I saw that there is also a download option through the FPGA invoke method but this method has absolutely no other info in or out of it.. So where does it download the file(s)??
    Also note that although my card is mounted as u: (getting this from the mount sd card invoke method), ftping
    ftp://xxx.xx.xx.xxx/u:/
    returns that there is no such location..
    Any thoughts?
    Thanks a lot, Harry
    Attachments:
    dl_rio.jpg ‏121 KB

  • I am recieving an Error code when I try to compile a program to an FPGA chp in a cRIO but I don't know what the code means.

    This is the message that I am recieving when I compile to the cRIO I am working with.
    FATAL_ERRORortabilityortDynamicLib.c:358:1.27 - dll open of library
       <C:/NIFPGA85/Xilinx\bin\nt\libGenXstTask.dll> failed due to an unknown
       reason.   Process will terminate. For more information on this error, please
       consult the Answers Database or open a WebCase with this project attached at
       http://www.xilinx.com/support.
    I have no idea what this means.  Thank you in advance for the help.

    UtahTiger;
    First let me ask a few basic questions
    What version of LV are you using?
    What OS is your development machine?
    When in the compile process does this error occur?
    Can you compile other (blank) VI's, id the problem with this particular project?
    Have you been able to compile this project before. what changed?
    Once I know a little more about your system we can narrow down the source of your error.
    Message Edited by Huter on 04-29-2009 04:16 PM

  • Error when running simulation with SIT 2010 on a cRIO 9073, what do I need to install on the cRio?

    Hi.
    I am trying to run a simulink model on a cRio 9073 using SIT 2010. I succesfully created the FPGA vi and the lvbit file in order to map input/outputs to the model. I also created the DLL and OUT for the model.
    When I run the interface VI on my computer, everything seems OK, until I get the following error and I am not able to run the simulation. I found a similar post earlier that suggests that I need to install the shared variable engine or the Simulation Interface Toolkit on my cRio. I tried to do both using MAX but could not find neither of the suggested installations.
    Thanks for the help!
    Items.viNI_SIT_driversupportVIs.lvlibIT Probe Model Items.vi loaded with errors on the target and was closed.
    LabVIEW:  Failed to load shared library SITs.*robeSignals:C. Ensure that the library is present on the RT target. Use MAX to install NI software or FTP to transfer custom libraries to the RT target.
    Items.viNI_SIT_driversupportVIs.lvlibIT Probe Model Items.vi loaded with errors on the target and was closed.LabVIEW:  Failed to load shared library SITs.*robeSignals:C. Ensure that the library is present on the RT target. Use MAX to install NI software or FTP to transfer custom libraries to the RT target.

    Hola jarcTec;
    Este tipo de error suena suele ocurrir cuando no se tienen las librerías apropiadas instaladas en el cRIO. Te recomendaría que abrieras MAX, debajo de la pestaña de Remote Systems selecciones tu dispositivo>> software, click derecho e instalar software. Aquí debes asegurarte que las librerías que te faltan estén instaladas en el cRIO. En Custom Installation selecciona SIT como opción para instalar en el cRIO tal y como se muestra en las imagenes.
    Espero esta información te sea de utilidad
    Exito en tu aplicación
    Marisol

  • Not able to create OUT file with "nidll_vxworks" in Matlab for use with the LabVIEW SIT 2010 and a cRio 9073, sh.exe error

    I am trying to compile an OUT file for my Simulink model using "nidll_vxworks" and run it using the Simulation Interface Toolkit for a cRIO 9073 . I am able to compile the DLL file using "nidll" and succesfully run the simulation using my PC as the host.
    I already downloaded the "gccdist" and "vxworks61gccdist" folders and copied them to "c:" When I build the model in Sumulink I get the following error at the end of the process (at the same time windows tells me that "sh.exe" has stopped working). If it matters I am running Windows 7 64bits, but using Matlab 2009b 32bits and LabView 2010 32 bits. ANY HELP WILL BE APPRECIATED. "QofV" is the name of my Simulink model and I changed to "XXX" parts of the file path.
    ### Linking ...
    rm -f "QofV.out" ctdt.c;nmppc QofV.o QofV_data.o rtGetInf.o rtGetNaN.o rt_logging.o rt_look.o rt_look1d.o rt_nonfinite.o  nidll_main.o rt_sim.o ode8.o    | tclsh c:/gccdist/WindRiver/vxworks-6.3/host/resource/hutils/tcl/munch.tcl -c ppc > ctdt.c 
    abnormal program termination 
    C:\Users\XXX\AppData\Local\Temp\make426012.sh: fork failed: no child processes [1]
    make: *** [QofV.out] Error 1 
    ### Real-Time Workshop build procedure for model: 'QofV' aborted due to an error.
    >> 
    ### Linking ...rm -f "QofV.out" ctdt.c;nmppc QofV.o QofV_data.o rtGetInf.o rtGetNaN.o rt_logging.o rt_look.o rt_look1d.o rt_nonfinite.o  nidll_main.o rt_sim.o ode8.o    | tclsh c:/gccdist/WindRiver/vxworks-6.3/host/resource/hutils/tcl/munch.tcl -c ppc > ctdt.c  
    abnormal program termination 
    C:\Users\XXX\AppData\Local\Temp\make426012.sh: fork failed: no child processes [1]make: *** [QofV.out] Error 1 ### Real-Time Workshop build procedure for model: 'QofV' aborted due to an error.>>
    ### Linking ...rm -f "QofV.out" ctdt.c;nmppc QofV.o QofV_data.o rtGetInf.o rtGetNaN.o rt_logging.o rt_look.o rt_look1d.o rt_nonfinite.o  nidll_main.o rt_sim.o ode8.o    | tclsh c:/gccdist/WindRiver/vxworks-6.3/host/resource/hutils/tcl/munch.tcl -c ppc > ctdt.c  abnormal program termination C:\Users\XXX\AppData\Local\Temp\make426012.sh: fork failed: no child processes [1]make: *** [QofV.out] Error 1 ### Real-Time Workshop build procedure for model: 'QofV' aborted due to an error.>> 
    Solved!
    Go to Solution.

    Hello jarcTec,
    I am not sure right now if you can do it, but this tutorial might help, also everything was made in Winddows 7 in this one.
    http://zone.ni.com/devzone/cda/tut/p/id/11654
    Take a quick look and let me know if it works!!!
    Luis Fernando
    National Instruments Cono Sur
    Ingeniería de Campo y Consultoría
    http://chile.ni.com/

  • Why do I keep getting error -65581 when trying to use a cRIO 9024 and c series modules

    I am simply trying to send out a digital high on DIO0 of a 9401 c series module and I get the following error every time.  
    Error -65581 occurred at Shared Variable in Send True Value Out.vi
    Possible reason(s):
    CompactRIO:  (Hex 0xFFFEFFD3) The FPGA personality currently running on the CompactRIO chassis does not support the RIO Scan Interface in this slot.
    This error or warning occurred while writing the following Shared Variable:
    \\NRL-CMG-cRIO\NI 9401-1\DIO0
    \\170.126.209.52\NI 9401-1\DIO0
    Any help would be greatly appreciated.
    Nate 
    Solved!
    Go to Solution.

    NMAYO,
    In your project view can you right click on the chassis in the cRIO and make sure that it is set for Scan Mode and not FPGA mode? Also, In the measurement and automation explorer you can check the cRIO and verify that it has Scan Engine Support installed on it. The tutorial below shows how to reformat a cRIO and install software on it, the later steps on software will allow you to check your cRIO.
    Reformatting a CompactRIO Real-Time Embedded Controller
    Ben Sisney
    FlexRIO V&V Engineer
    National Instruments

  • RT cRIO: Shared Variable Engine Errors

    This is an app written in LV2011 running on a cRIO-9076 (Scan mode), with the August release of software installed on it.
    I have gown to great lengths to try an optomize my code, I have reached an impasse.  The VERY FIRST TIME I run the code on the target (be it via a self-starting EXE or targeting from my Windows development machine I am able to read and write to several shared variables, but then when I access them again (possibly when I am starting a couple timed loops and the processor is very high) I get this:
    Error -1950679023 occurred at Shared Variable in targetIdleLoop.vi->ZDAQ_cRIO_Target_Main.vi
    Possible reason(s):
    LabVIEW:  (Hex 0x8BBB0011) The connection to the server was disconnected.
    This error or warning occurred while writing the following Shared Variable:\\ZeeAero-RIO1\variables - network - RT (separate)\RTStatus\\10.10.10.10\variables - network - RT (separate)\RTStatus
    If I go back to the Dev machine and restart the code, I don't get this error; it only happens after a reboot.
    BUT on this second run (or subsequent VI starts), when we get to that same point, a client priogram running on Windows and reading a network variable successfully suddenly gets:
    LabVIEW:  -1950679035 (Hex 0x8BBB0005) Unable to locate variable in the Shared Variable Engine.  Deployment of this variable may have failed.
    Which lasts a minute or so, then goes away.  The code is made to loop, and when it loops back through this point there are no errors at all.
    So, to recap:
    1st Run after reeboot, 1st loop :Error on Target (0x8BBB0011), connection to server disconnected
    Subsequent Runs, 1st loop: Error on Windows Client (0x8BBB0005) Unable to locate variable in the Shared Variable Engine.  Deployment of this variable may have failed.
    Subsequent Runs, 2nd+ loop: No error
    Here is a link to a screenshot of the installed SW on the Target:
    EDIT:  I should mention that there are three loops running in parallel on this app; 1 is a Timed-loop (at the moment) set to a period of 10ms with 100 priority, #2 is also a timed loop and is set to 3ms with priority = 50 and the third is a WHILE loop with a 50ms wait.  The error occurs during the WHILE init phase, which happens once per run, not repeatedly.
    Solved!
    Go to Solution.

    This is killing me.  It's obviously something to do with when the Timed loops start AND when I access the network variables.
    See the screenshot below.
    Note that I read and write to several network variables in Subroutines to the left of this screenshot at startup.  The starting of the timed loops causes the issue with the shared variables.  (also note that the periods are set to 100ms and 99ms in my testing after the initial 1st loop.
    Now look at the Wait at the bottom set to 10 seconds.  In this case, it will work.  There is no error at breakpoint 37 if I wait around 10s.  If I DON'T wait the 10 seconds, there is an error after the check on the BOOL "stop - Network" variable that NEVER GOES AWAY.  If I look at the CPU monitor, there is an initial bump in the cpu when starting the loops, and then it drops to about 15%.  But if I don't have that 10s wait, there is ERR 0x8BBB0011 and the CPU spikes to 75% every 5 seconds and it never goes away.
    And that's only the 1st loop after reboot.  The 10s makes this work, but I still have an issue with it once I start doing individual runs (loops).

Maybe you are looking for

  • Files on external FAT32 hard drive have disappeared

    My friend attached her external USB hard drive to my Mac. She didn't know that she was supposed to eject her drive before pulling the USB cord. Now, she can't see any of her files when she attaches her drive to her Windows XP machine. She's very upse

  • HT2455 how do I change the order of the songs on my playlist?

    I have 68 songs on my playlist.  Somehow the songs are all in alphabetical order, making my duplicates all play in a row.  How do I change the play order?

  • Can not understand why it is not working, plz help.

    I am a student trying to understand flex builder 3, but it is very hard and when something is going wrong I think that I will never undersand how is it working. Hete is my program and do not see a problem. Maybe someone could help me? MAIN APLICATION

  • Stop full-screen windows in DW CS6 interface.

    My preference for using DW is to have code view, site files & that's it. I really dont need any other feature. I have turned off the Application frame in DW CS6 & saved my workspace preference as code & site only. However whenever I open a file, it a

  • User Exit for FI Postings