Exception Raising in Function Module

Hi,
I am having a custom function module that calls a standard function module. Custom function module has following exception defined: manufacture unknown.
Standard function module has enhancement sections that I implement. For a defined condition I have to raise an exception and return from the function module. However, the exception is not defined in function module.
Standard exception OTHERS is available. Is it possible to raise OTHERS exception from the code? I have tried statement Raise OTHERS. But it has syntax errors.
Regards,
Bhavish Bhatia

Hi,
If you raise an exception not defined at exception's tab, sy-subrc will be returned with the number of exception OTHERS.
Just with the sentece:
RAISE ZEXCEPTION. (Assuming that ZEXCEPTION is not included at exception's tab).
Regards,
Pablo.

Similar Messages

  • How to see the exception raised  in function module...

    DEAR ABAPERS,
    how can i see that exception, when iam excuting
    Regards,
    veera

    hi Veera,
    Based on SY-SUBRC value we can handle those exception in this way ..
      if sy-subrc = 1.                    
        raise file_write_error.           
      elseif sy-subrc = 2.                
        raise gui_refuse_filetransfer.    
      elseif sy-subrc = 3.                
        raise gui_refuse_filetransfer.
    Regards,
    Santosh

  • Exceptions in the function module

    Hi,
      I declared exceptions in the function module. But those exceptions not trigger in the abap editor.
    Regards
    Srinu

    Hi
    use RAISE EXCEPTION...
    RAISE KEY WORD IT WILL DEFENETELY RAISE THE EXCEPTION..
    REWARD IF IT USE FUL

  • How do we trap exception inside the function module?

    How do we trap exception inside the function module?

    Use ABAP Help - CATCH, RAISE for starters. Or take a look at an existing function module, for example.

  • Customer 9000AAAE : Exception 7 in function module VIEW_KUAG2

    Hi,
    Hi all,
    When I do the intercompany billing for STO (vf01), I got the system message attached below. The customer 9000AAAE is a ship to party and assigned to the ordering plant. It has the partner function SH. So can anybody kindly tell me where is wrong in the custmer master data or somewhere else according to the following message? Or where to find the VIEW_KUAG2? What does it mean?
    Customer 9000AAAE: Exception 7 in function module VIEW_KUAG2
    Diagnosis
    During the attempt to read customer master record 9000AAAE,
    an error occured which is not handled separately.
    System Response
    The billing document for this business transaction was not
    created.
    Procedure
    If the error occured during a background job, you should try
    to create the billing document online. If the error occured
    online, the billing document can be created online. In any
    case, you should check the customer master record. If you
    cannot find any error in the master data, contact SAP.
    Technical data
    Tech. data details
    Client                                                002
    Group Number
    Sales Document Number                  0080100090
    Item Number of the SD Document      000000
    Schedule Line Number                      0083
    Counter in Control Tables                  00
    Message Identification                      VF
    System Message Number                 083
    Output Type                                     E
    Message Variable 01                        9900AAAE
    Message Variable 02
    Message Variable 03                        VIEW_KUAG2
    Message Variable 04
    Group Type                                      F
    In our Intercompany, our ship to party is different from the Sold to, bill to and Payer.  The configuration done as follows -
    a.  Defined Ship to Party as 9000AAAE
    b.  Define Sold to, Bill to, Payer as 9000AAAA
    c.  Assignd Ship to Sold to
    d.  Assigned Ship to customer to plant assignment in STO configuration in MM
    e.  Assigned internal customer of sales organization as 9000AAAA
    Please help in this
    Best Regards
    Goutham

    Hi,
    Thanks for ur reply
    I check the partner determination and the settings are as below -
    a.  Defined new account group for Sold to, Bill to and Payer
    b.  Defined new account group for Ship to
    c.  In the Ship to party account group, system only determine the ship to partner function
    d.  Customer defined in Sold to is assined as interneal customer to sales org
    e.  Customer defined in Ship to is assigned as customer for plant in Shipping data configure for STO in MM Configuration
    Please provide more insights
    Best Regards
    Goutham

  • How to use Exceptions for a function module

    Hi folks,
            I have created  a new function module.Its working fine, but i am not aware of using exceptions for a function module. I hav just declared an exception in the 'exception' tab. Could any body explain me how to use that in my FM source code....Thanks...

    Hi Shyam,
    Have a look at this,
    START-OF-SELECTION.
      gd_file = p_infile.
      CALL FUNCTION 'GUI_UPLOAD'
        EXPORTING
          filename                = gd_file
          has_field_separator     = 'X'  "file is TAB delimited
        TABLES
          data_tab                = it_record
        EXCEPTIONS
          file_open_error         = 1
          file_read_error         = 2
          no_batch                = 3
          gui_refuse_filetransfer = 4
          invalid_type            = 5
          no_authority            = 6
          unknown_error           = 7
          bad_data_format         = 8
          header_not_allowed      = 9
          separator_not_allowed   = 10
          header_too_long         = 11
          unknown_dp_error        = 12
          access_denied           = 13
          dp_out_of_memory        = 14
          disk_full               = 15
          dp_timeout              = 16
          OTHERS                  = 17.
        IF sy-subrc NE 0.
          write: 'Error ', sy-subrc, 'returned from GUI_UPLOAD FM'.
          skip.
        endif.
    Regards,
    Sai

  • Customer : Exception 7 in function module VIEW_KUxxV

    Hi,
    While Billing facing this problem
    00 Customer : Exception 7 in function module VIEW_KUxxV
    10 The bill-to party could not be determined
    10 The payer could not be determined
    tx in advance
    Bhushan Kolte

    Hello Colleague;
    Please check the account group assignment to the partner functions in   
    transaction VOPA click on partner function button then environment      
    then Account group assignment. Please ensure that this is all configured
    correctly for the partners.                                                                               
    Please also review the note                                    
    -> 80233   Debit-side settlement: Customizing, error messages                                                                               
    In particular the section:                                              
    VF083: 'Customer &: Exception & in function module VIEW_KUAGV'                                                                               
    The error message is generated because of a program error that          
    has since been corrected. The correct error message is VP304,           
    'Customer belongs to customer group & and thus cannot be the            
    sold-to party'.                                                                               
    The partner roles in the customer master are incorrectly set, see       
    below.                                                                               
    Recommendation: Assign the customer an account group which              
    already fulfills these criteria. (In the standard system, this is       
    Account group '0001).                                                                               
    I hope this helps resolve the error.
    Regards
    Ruy Castro

  • Exception 7 in function module VIEW_KUAG2

    Hi all,
    When I try to process a Billing document in transaction VF04, has an error message "Customer 12334: Exception 7 in function module VIEW_KUAG2".
    Could you advise me why I receive this message?
    Is it possible that Customer master data it is not maintained propertly?

    Hi,
    When I checked there are only 5 exceptions for this functional module.  By the way which version are you in?  If you want to find out what the exception 7 is then go to SE37 and display this functional module.  There you can find a tab for exceptions.  Based on that you can proceed with changes in the customer master. 
    Its definitely the possibility of not maintaining the customer properly.
    Hope this helps.
    Thanks
    Krishna.

  • Catch the Exceptions of standard Function Module

    Hi Experts,
    I am Using Version 4.6C.
    I am developing an RFC for creation of commitments into the system for this i have used 'FMFR_CREATE_FROM_DATA'  Function Module. But i need to capture the System exception so as to alert the user when it puts in invalid data. However function Module 'FMFR_CREATE_FROM_DATA' is working fine but   I am unable to System Exceptions i have tried using Function Module FORMAT_MESSAGE by importing the system variable into it but my program gets append ever time an system exception raised.
    Can anyone help in getting it fix.

    Hi,
    Which thrid party system you are configuring check the system destinations propely given or not and in third parthy which type error or any message u r getting or not.  Once if it is working find in from R/3 to other it is not RFC problem it may related to u r settings or in third parthy system not set properly.
    contact your basis teams
    Regards
    Ganesh

  • Exception while executing Function module - HRXSS_PER_READ_P0006_US

    Unable to execute any of the following Function modules(ECC 5)
    (Gave the neccesary inputs)
    HRXSS_PER_P0006_US
    HRXSS_PER_DELETE_P0006_US
    HRXSS_PER_EDIT_P0006_US
    HRXSS_PER_MODIFY_P0006_US
    HRXSS_PER_NEW_P0006_US
    HRXSS_PER_READ_P0006_US
    Getting an exception
    Runtime Errors OBJECTS_OBJREF_NOT_ASSIGNED_NO
    Exceptn CX_SY_REF_IS_INITIAL
    ShrtText
    Access with 'ZERO' object reference not possible.
    What happened?
    Error in ABAP application program.
    The current ABAP program "SAPLHRXSS_PER_MAC" had to be terminated because one of the statements could not be executed.
    This is probably due to an error in the ABAP program.
    Error analysis
    An exception occurred. This exception is dealt with in more detail below . The exception, which is assigned to the class 'CX_SY_REF_IS_INITIAL', was neither caught nor passed along using a RAISING clause, in the procedure "HRXSS_PER_CLEANUP" "(FUNCTION)".
    Since the caller of the procedure could not have expected this exception to occur, the running program was terminated.
    The reason for the exception is:
    There was an attempt to access a component using a 'NULL' object reference (points to nothing).
    An object reference must indicate an object (an instance of a class), before it can be used to access components.
    Either the reference was never set or it was set to 'NULL' using a CLEAR statement.
    Missing RAISING Clause in Interface
    Program SAPLHRXSS_PER_MAC
    Include LHRXSS_PER_MAC$04
    Row 7
    Module type (FUNCTION)
    Module Name HRXSS_PER_CLEANUP
    Trigger Location of Exception
    Program SAPLHRXSS_PER_MAC
    Include LHRXSS_PER_MACU04
    Row 13
    Module type (FUNCTION)
    Module Name HRXSS_PER_CLEANUP
    What could be the reason?
    Regards,
    Sarath

    Hi Sarath,
    The problem is caused by a program error in the CRM system.
    Solution for this is Import the Support Package or implement the correction instructions as specified in note 742720, there are some corrections attached to the note. Hope this will resolve the issue.
    Cheers,
    Shyam.

  • Uncatchable exception: BSP calling Function Module

    Hi all,
    currently i'm facing a very weird problem. My application class calls function module
    HR_INFOTYPE_OPERATION. Normally, in case of an error, the function module gives you back a return parameter. But if i call it from my BSP, the processing doesn't leave the function module. It directly throws an exception ERROR_MESSAGE_STATE instead of writing the message into parameter return.
    If i call the function module with the same parameters from a report, it works fine and the error message is written to return parameter without throwing an exception.
    What am i doing wrong? I don't want that exception and need to go on with filled parameter result.
    Regards
    Mark-André

    Hi MA,
    try using ERROR_MESSAGE in the exceptions list, like this.
    CALL FUNCTION 'func_name'
         EXPORTING
              string            = text
              pos               = position
         IMPORTING
              string1           = text1
              string2           = text2
         EXCEPTIONS
              string1_too_small = 1
              string2_too_small = 2
              ERROR_MESSAGE     = 3
              OTHERS            = 4.
    Cheers
    Graham Robbo

  • Exception handling in function module

    Hi experts,
    when we write the function module in the report program like "CONVERT_TO_LOCAL_CURRENCY"  if anything goes wrong in this FM the program goes to dump. So how to handling this exceptions.
    if sy-subrc ne 0 then i need to continue with the next statement.  will i need to use continue statement.
    Please expllain with some example

    hello,
    CALL FUNCTION 'CONVERT_TO_LOCAL_CURRENCY'
    EXPORTING
    CLIENT = SY-MANDT
    date = itab-date_of_export
    foreign_amount = dl_kwert
    foreign_currency = itab-waers
    local_currency = c_usd
    IMPORTING
    local_amount = itab-value_of_goods
    EXCEPTIONS  " un-comment these sections
    no_rate_found = 1
    overflow = 2
    no_factors_found = 3
    no_spread_found = 4
    derived_2_times = 5
    OTHERS = 6.
    IF sy-subrc NE 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO  " this is display the system message automatically when ever exp are hit
    WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    here you can use the  case statement like:
    case sy-subrc.
      when 1.
    write your code what you want to do if no rate found
      when 2.
    what do you want to do in case of overflow.
    *similarly handle all the cases of exceptons
    endcase.
    hope it helps
    regards
    geeta gupta

  • How to raise the exception in function module

    Dear abaper's.
                   I am creating a Function module .In that in' EXCEPTION' Tab i am giving
    3 exception .1.NO_DATA_FOUND 2.NO_PRINTER_FOUND 3.SMARTFORM_INTERFACE_NOT_FOUND.
    In my coding if this condtion matches i want to raise this exception.how can i do this in my coding .can any one suggest me..
    advance thanks,
    Warm regards,
    Veera

    Hi,
    if that condition is not satisfied,and u didn't handle that exception while calling function module then in the runtime error u will get the text as the description of the exception in function module definition.
    rgds,
    bharat.

  • Raise exception in function module call from SAP owned program

    I need to raise an exception in a function module to terminate a transaction, display a error message and return to to previous selection screen so the user can fix the error before moving forward.......  
    How do you do this when the program using the function module is SAP owned?
    Thank You!
    Jeff

    Hi,
    After calling the function module, you can do something like this.
    IF SY-SUBRC <> 0.
      RAISE EXCEPTION.
    ENDIF.
    Regards,
    Ferry Lianto

  • Exceptions in Function Modules

    Hi
    How can I create an Exception in a Function Module and Raise that based on some condition? Plz help

    Hi Santo,,,,
    Look into this link ,, where u will get  a clear information on exceptions,,,,,
    http://help.sap.com/saphelp_nw70/helpdata/en/9f/db98fc35c111d1829f0000e829fbfe/content.htm
    http://abapprogramming.blogspot.com/2007/06/lesson-24-function-groups-and-function.html
    In the function module, you can create your own local types and data objects, and call subroutines or other function modules.
    You can make a function module trigger exceptions .
    To do this, you must first declare the exceptions in the interface definition, that is, assign each one a different name.
    In the source code of your function module, you program the statements that trigger an exception under the required condition. At runtime, the function module is terminated when an exception is triggered.
    The changes to exporting and changing parameters are the same as in subroutines. There are two statements that you can use to trigger an exception. In the forms given below, stands for the name of an exception that you declared in the interface. The system reacts differently according to whether or not the exception was listed in the function module call:
    RAISE .
    If the exception is listed in the calling program, the system returns control to it directly. If the exception is not listed, a runtime error occurs.
    MESSAGE () RAISING .
    If the exception is listed in the calling program, the statement has the same effect as RAISE . If it is not listed, the system sends message from message class with type , and no runtime error occurs.
    Function modules differ from subroutines in that you must assume that they will be used by other programmers. For this reason, you should ensure that you complete the steps listed here.
    Documentation (can be translated)
    You should document both your parameters and exceptions with short texts (and long texts if necessary) and your entire function module. The system provides a text editor for you to do this, containing predefined sections for Functionality, Example Call, Hints, and Further Information.
    Work list
    When you change an active function module, it acquires the status active (revised). When you save it, another version is created with the status inactive . When you are working on a function module, you can switch between the inactive version and the last version that you activated. When you activate the inactive version, the previous active version is overwritten.
    Function test
    Once you have activated your function module, you can test it using the built-in test environment in the Function Builder. If an exception is triggered, the test environment displays it, along with any message that you may have specified for it. You can also switch into the Debugger and the Runtime Analysis tool. You can save test data and compare sets of results.
    When you insert a function module call in your program, you should use the Pattern function. Then, you only need to enter the name of the function module (input help is available). The system then inserts the call and the exception handling (MESSAGE statement) into your program.
    You assign parameters by name. The formal parameters are always on the left-hand side of the expressions:
    Exporting parameters are passed by the program. If a parameter is optional, you do not need to pass it. Default values are displayed if they exist.
    Importing parameters are received by the program. All importing parameters are optional.
    Changing parameters are both passed and received. You do not have to list optional parameters.
    Default values are displayed if they exist.
    The system assigns a value to each exception, beginning at one, and continuing to number them sequentially in the order they are declared in the function module definition. You can assign a value to all other exceptions that you have not specifically listed using the special exception OTHERS.
    If you list the exceptions and one is triggered in the function module, the corresponding value is placed in the return code field sy-subrc. If you did not list the exception in the function call, a runtime error or a message occurs, depending on the statement you used in the function module to trigger the exception.
    When you create a function module, you must assign it to a function group. The function group is the main program in which a function module is embedded.
    A function group is a program with type F, and is not executable . The entire function group is loaded in a program the first time that you call a function module that belongs to it.
    The system also triggers the LOAD-OF-PROGRAM event for the function group.
    The function group remains active in the background until the end of the calling program. It is therefore a suitable means of retaining data objects for the entire duration of a program. All of the function modules in a group can access the group's global data.
    Please reward if found helpful,,,,,,,,,,,,,,,,
    Thanks And Regards ,,,,
    Sreekar.Kadiri.