Executable not working - Looking for LabVIEW Run-Time Engine

This has been one of those days.
I'm trying to create my .exe file to place onto another computer. I've done this before with success. But that was then and this is now.
I believe I have all the files I need in my LLB, and I believe I did my application distribution correctly and I believe I built the DLL correctly. But when I took the resulting .exe file and placed it on another computer and attempted to run it, it gave me the error message: "Unable to locate LabVIEW Run-Time Engine. Program requires a version 7.1 (or compatible) LabVIEW Run-Time engine. You should have already realized this, you moron."
Anyone have any idea where I went wrong or what step I might have missed? This has been a crazy, non-stop, massive brain fart of a day and I can't seem to remember what I'm missing here.
Amateur programmer for over 10 years!

Hi.
Whenever you want to use executables or .dll's created with LabVIEW you must make sure that the LabVIEW runtime engine of the SAME version as the LabVIEW version used to create the files, is installed in the target computer.
There are basically 2 ways to get the run-time engine installed on a computer:
1. (the one I prefer): Download the correct version of the LabVIEW run-time engine installer from www.ni.com/downloads, or more specifically from
http://digital.ni.com/softlib.nsf/websearch/369618​104E25B08E86256F54006A4E2F?opendocument&node=13205​0_US
for the latest one. Once you have the installer for the run-time engine, just install it in the target computer. I prefer this option because the run-time engine is installed independently, so if you then uninstall your program, the run-time engine remains.
2. Create an installer for your program that includes the run-time engine. To include the run-time engine, when you are creating your application, go to the "installer settings" tab, click on "Advanced" and make sure there is a checkmark on "include LabVIEW run-time engine". This way when you install your program in the target computer, the run-time engine will also be installed.
Just as a note, any computer with LabVIEW on it, will also have the run-time engine.
Good luck.
Alejandro

Similar Messages

  • System requiremen​t for Labview run-time engine 8.6

    Hello
    is there any system requirements for LabVIEW Run-time engine 8.6? for example, same system requirements for LabVIEW 8.6? Internet Explorer 5 is fine? or Internet Explorer 6.0 or higher is fine? Does it work for Firefox on an Athena Linux mechine?
    Thanks
    Cynitha
    Solved!
    Go to Solution.

    The system requirements can be found in the Release Notes. Pages 2 and 3 indicate the specific requirements for the Run-Time Engine per platform.

  • Unable to locate the LabVIEW Run-Time engine

    Using LabVIEW 2011, I have built an executable and installer including the LabVIEW Run-Time engine. I built the app on a 32-bit system. I'm deploying it to a Windows7 64-bit system. When I ran the installer, rebooted, then tried to run the app, I got an error messsage stating "Unable to locate LabVIEW Run-Time Engine", stating that the LVRTE 2011 was needed to run the app, and asking if I want to download from NI. I have tried downloading the RTE and re-installing it, but when I try, I get an error message from the installer stating that there is a newer version of the RTE already installed, and the installer exits! I have tried un-installing the application, but have had no luck removing the RTE. Now I'm stuck. The re-installed executable application says it can't find the RTE, and the RTE installer says there's a later version already installed!
    I can't go forward or backwards!
    Prior to running the installer for this app, I had a working LVRTE for 2011, and was running some other executable LabVIEW programs on the target box. However, since this new application had additional components not included in the original install of the RTE, I built the new installer which included the additional components. Once I ran that installer, my problems began.
    In my frustration, I've tried downloading from NI both the 32 and 64-bit versions of the RTE, and installing them. I realize that the app was built on a 32-bit system, so the 32-bit RTE SHOULD have run it fine, but didn't.
    At this point I have removed the 64-bit RTE using the NIUninstaller. I believe I need to completely remove all 32-bit RTE components and start over, but I have not been able to. The 32-bit RTE does not show up in any un-install utilities I've found.
    What could be causing this problem, and how do I get past it??
    Thank you.

    One thing I did discover in my struggles is that the RunTime engine on the target box needs to be based on the environment of the development box. So if you built the app on a 32-bit machine, you would need to install the 32-bit RTE, even on your 64-bit target box.
    The RTE Uninstaller might not show up in the Windows Add/Remove Programs utility. In my case the 64-bit RTE uninstaller showed up, but the 32-bit did not. The NiUninstaller (C:\Program Files\National Instruments\Shared\NIUninstaller) did list both RTEs for uninstalling, but still didn't get me past the problem.
    I was finally only able to get past the problem by doing a system restore to a point in time prior to my changing of the RTE.
    Good luck.
    Dan

  • Why do different versions of the LabVIEW Run-Time Engine not compatible?

    LabVIEW Run-Time Engine to become more and more big
    Why do different versions of the LabVIEW Run-Time Engine not compatible?
    " 一天到晚游泳的鱼"
    [email protected]
    我的个人网站:LabVIEW——北方客栈 http://www.labview365.com
    欢迎加入《LabVIEW编程思想》组——http://decibel.ni.com/content/groups/thinking-in-labview
    Solved!
    Go to Solution.

    jwdz wrote:
    LabVIEW2020 ....... ,it look like?
    You need to express your ideas more clearly. We cannot fill in the blanks and read between the lines if the post has no substance.
    jwdz wrote:
    It will affect the future development of LabVIEW, right?
    What is "it"?
    There are many things that affect the future development of LabVIEW, starting with NI management, all the smart people in LabVIEW development, the economy, the LabVIEW users, etc.
    If you are worried about the increasing size of the distribution, the good news is that the cost of data storage and data transmission has dropped much more dramatically. Even though newer versions are bigger due to great and welcome new features, the improvements in infrastructure have actually made the distribution and storage significantly easier over the years and will continue to do so. Trust me!
    Nobody wants to go back to a LabVIEW version that fits on a floppy disk!
    LabVIEW Champion . Do more with less code and in less time .

  • LabVIEW 2011SP1 Error building installer: LabVIEW Run-Time Engine 2013 is missing 3 dependencies???

    I'm having a problem building an installer in LabVIEW 2011SP1.
    It's been a while since I've tried to build an installer but it used to work fine and building executables is still working fine.
    Now when I try to build the installer I get "The build was unsuccessful."
    Possible reasons: Error generating preview for My Application 3.1.7.
    Details:
    Visit the Request Support page at ni.com/ask to learn more about resolving this problem. Use the following information as a reference:
    CDK_Build_Invoke.vi.ProxyCaller >> CDK_Build_Invoke.vi >> CDK_Engine_Main.vi >> IB_MSI.lvclass:Build.vi >> IB_MSI.lvclass:Engine_InitializeDistribution.vi >> IB_MSI.lvclass:Report_Preview_Error.vi >> IB_Source_Container.lvclass:Report_Preview_Error.vi
    Loading product deployment information
    *** WARNING ***
    NI LabVIEW Run-Time Engine 2013 is missing 3 dependencies. This product, or other products that depend upon NI LabVIEW Run-Time Engine 2013, may not function properly while the dependencies are missing.  Visit ni.com/info and enter the Info Code "" for more information.
    *** Error: An internal error occurred for which the cause is unknown. (Error code -41)
    *** Error Details:
    Error in MDF API function: _MDFCommon_GetNextLogMessage
    Error in MDF::GetInstance - MDF static instance is not initialized!
    *** End Error Report
    Loading product deployment information
    *** WARNING ***
    NI LabVIEW Run-Time Engine 2013 is missing 3 dependencies. This product, or other products that depend upon NI LabVIEW Run-Time Engine 2013, may not function properly while the dependencies are missing.  Visit ni.com/info and enter the Info Code "" for more information.
    The really strange thing about this is that I'm using LabVIEW 2011SP1, I don't even have LabVIEW 2013 installed, not even the runtime.
    Where is the problem? Why is it even complaining about LabVIEW 2013? Has anyone seen this before?
    Troy
    CLDEach snowflake in an avalanche pleads not guilty. - Stanislaw J. Lec
    I haven't failed, I've found 10,000 ways that don't work - Thomas Edison
    Beware of the man who won't be bothered with details. - William Feather
    The greatest of faults is to be conscious of none. - Thomas Carlyle
    Solved!
    Go to Solution.

    I do have the LabVIEW 2013 discs but didn't install it.
    I checked in Control Panel > Programs and Features > National Instruments Software and the LabVIEW 2013 Run-Time is not listed there.
    I also checked in MAX > Software and I must have missed it the first time I looked. LabVIEW Run-Time 2013 is listed there after all.
    Now I remember installing VISA 5.4 to get rid of a nasty bug. It must have installed the 2013 Run-Time when I did that.
    So now I need to distribute 2 runtimes with my application?!?!
    Troy
    CLDEach snowflake in an avalanche pleads not guilty. - Stanislaw J. Lec
    I haven't failed, I've found 10,000 ways that don't work - Thomas Edison
    Beware of the man who won't be bothered with details. - William Feather
    The greatest of faults is to be conscious of none. - Thomas Carlyle

  • Include LabVIEW Run-Time Engine in C# Project Distribution

    I have written a software package in Visual Studio using C# which calls a number of functions from a dll which I have built in LabVIEW. I am now trying to produce an installation program for my C# package but can't quite work out how to include the LabVIEW Run-Time Engine in this installation.
    I am creating the installation program by defining a Visual Studio Deployment Project and I have added my LabVIEW dll to this. However, the dll requires the LabVIEW Run-Time Engine to also be installed on the target PC. I was hoping that there would be a set of files to implement the installation of the LabVIEW Run-Time Engine that I could include in my Visual Studio Deployment Project and do the installation of both my C# code and my LabVIEW dll (inc Engine) in one operation. Is this possible? Or do I need to produce a LabVIEW installation for my dll separately from the C# installation?
    Info:
    Development OS = Windows 2000
    Target OS = Windows XP
    C# Development Environment = Microsoft Visual Studio 2005 V8.0
    LabVIEW Version = 8.5
    Also, I am using the Order Analysis Toolkit and noticed that there seemed to be an 'Order Analysis Run-Time Engine' installed on my PC. Do I need this too?
    Thanks for any help.
    CAS

    Hi CAS,
    One way of automating the installation of the LabVIEW run-time engine is to use commands in a batch file (*.bat). These commands would be executed automatically at the same time as your distribution installer to install LVRT with your C# application. For more information on command line options, have a look at this KB. I don't have so much knowledge of C# distributions, though, so there may be a better way to approach this that someone else in the community could advise you on.
    With regard to the order analysis toolkit, you will also need this runtime engine installed. A point to note, though, is that the toolkit requires a run-time licence to be deployed in this fashion. It is now part of the Sound and Vibration Measurement Suite and needs to be licenced accordingly.
    I hope this helps!
    Best regards,
    Tom
    Applications Engineering, NI UK

  • Error -17600 when switching from LabVIEW Development System to LabVIEW Run-Time Engine in Adapter Configuration

    I receive an error message (code -17600) while loading my test sequence after switching from LabVIEW Development System (2009 f3) to LabVIEW Run-TIme Engine using the Adapter Configuration.
    ErrorCode: -17600,
    Failed to load a required step's associated module.
    LabVIEW Run-Time Engine version 9.0.1f3.
    When I switch back to the LV development system, everything is OK, and the sequence loads and runs perfectly.
    My TestStand Engine Version is 2012 f1 (5.0.0.262).
    I'd appreciate any help on this issue.
    Roman

    Hi Roman,
    There are a couple of things you can try:
    1) Determine if the LabVIEW RunTime Engine is corrupted in some way. Create a new simple VI with no sub-VIs, using the same LabVIEW Development system you used for mass-compiling the VIs. Create a TestStand step that calls this VI and ensure it runs correctly. Now switch your LabVIEW adapter to use the RuntimeEngine and choose the "Auto detect using VI version" option.
    Check if the simple VI is loadable and runs without errors in TestStand.
    If the step generates the same error, you should try a re-install of the LabVIEW development system.
    If not, its most likely that there is some VI you are using that is not loadable in the LabVIEW Runtime Engine because:
    1) Some sub-VI is still not saved in the right version or bitness. Open the VI heirarchy of the top-level VI that you are calling from TestStand and examine the paths of all the sub-VIs to check if they were in the folder you masscompiled and re-save any that are outside this directory.
    Also, when you try to close the top level VI, do you get a prompt to save any unsaved files? If so, they could be the sub-VIs that are not saved in the right version. Save all of them.
    Check if you are loading any VIs programatically and if these are compiled and saved in the right version as well.
    2) There is some feature you are using in your LabVIEW code that is not supported in the LabVIEW RunTime Engine. To check this, add your top-level VI to a LabVIEW project and create a new build specification and create a new executable from this VI.
        Right-click "Build Specifications" and choose "New->Application(EXE)".
        In the Application Properties window, select Source Files and choose the top level VI as the start-up VI.
        Save the properties.
        Right-click on the newly created build specification and choose Build.
    Run this executable (it will be run using the LabVIEW RunTime) and check if the VI has a broken arrow indicating that it cannot be loaded and run in the LabVIEW Runtime Engine.
    You might need to examine your code and find the feature which is not supported in the LabVIEW RunTime and find an alternative.
    Another thing i forgot to mention the last time around is if you are using 64-bit LabVIEW with 32-bit TestStand, then executing code using LabVIEW RTE from TestStand will not work since the 64-bit LabVIEW RTE dll cannot be loaded by the 32-bit TestStand process.
    If none of the above steps resolve the issue, consider sharing your LabVIEW code so i can take a look.
    Regards,
    TRJ

  • Teststand error states that a vi failed to load in the Labview Run-Time Engine

    I am getting an error in teststand that states that a vi failed to load in the Labview Run-Time Engine version '14.0.1'
    If I look at the software loaded on my system with the NI Measurement and Automation Explorer I have Labview Run Time engines for version 2009, 2010, 2011, 2012, 2013, & 2014 on my system.
    How do I get this VI to run on this system when it is called by test Stand?
    Thank you

    The RTE 14.0 was loaded as part of my deployment and after I ran this I got an update notice for the F1 patch which I also loaded.
    I do not have labview loaded on this system, only the run time engines from running my deployment.
    When I launch t he teststand sequence, when it calls the labview VI, I get the following error moessage:
    Error: Failed to load VI 'C:\builds\RelayVoltageMeaure.vi' in the LabVIEW Run-Time Engine version '14.0.1'. LabVIEW: The VI is not executable. This error may occur because the VI is either broken or contains a subVI that LabVIEW cannot locate. Select File>>Open to open the VI and verify that you can run it. VI Path: C:\builds\RelayVoltageMeaure.vi[Error Code: -17600, Failed to load a required step's associated module. ]
    I have attached the teststand sequence if this helps.
    Thanks
    Attachments:
    QuantumDigitalBd.seq ‏13 KB

  • Unable to locate labview run time engine (lab view 8.5)

    Hello I have a problem whit the labview 8.5 installer. I have created I project with included a .vi file (a simple panel wich control a serial port, with parameters (baud rate, stop bits, ...)), then I have created an application for this file (.exe) and then the installer (I have included the labview run time engine 8.5). When I run the setup.exe  I have the following error message:
    Unable to locate labview run time engine, the application require a labview run time engine 8.5 or compatible...
    What I'm missing??
    Thanks
    Maurizio

    are there one other reasons why it would not work.  I have asimilar problem.
    I intsalled version 8 of run time engine and acrtivated software.  Now I am trying to run compiled application provided to me by third party.
    When I click on application it says
    Unable to locate LV run time engine
    Test server requires a version 6.0 or compatible LV engine.
    How do I know if the engine I installed and activated is running and is it supposed to be able to execute a program which is expectin rev 6 of the rund engine?

  • MAX giving error - Unable to locate Labview run-time engine

    I have LV 7.1 and 8.5.1 installed on a WinXP pc. No problems until now.
    I installed some support software for a LabJack  interface, which required LV version 6.1 run-time, so I let it install that.
    I now get the error whenever I run MAX:
    "Unable to locate the Labview run-time engine. LVBrokerAux71 requires a version 7.1 (or compatible) Labview run-time engine...."
    After closing the error boxes, MAX seems to work fine. Both versions of Labview also work. I uninstalled run-time engine 6.1 and re-installed version 8.5.1, but that made no difference. I tried to install run-time version 7.1 from the msi file but it would not let me because a later version of the run-time is installed.
    What is LV Broker? Why does it not accept version 8.5.1 run-time engine? Is it possible to have 2 versions of the run-time engine installed, and if so, how?

    Dear CDancer
    Thank you for contacting NI. First of all, you can have as many versions of LabVIEW run time engines you want loaded on your computer without a problem. LV Broker is installed by all drivers that uses LabVIEW testpanels like DAQmx does. In your case it seems that the LV Broker installation is corrupted or has failed. This can be rectified by overwriting the files in the specified directory listed below:
    C:\Program Files\National Instruments\Shared\LabVIEW Broker
    Your directory should look like the screenshot I have attached; labelled LV Broker Directory View
    I have attached a ZIP File that will replace the LV Broker directory. Please try replacing your files with these if different to the screenshot and let me know how you get on. Many thanks.
    Many thanks for using the NI forums and I look forward to your reply.
    Kind regards
    David
    Applications Engineer
    National Instruments UK
    Attachments:
    LV Broker Directory View.JPG ‏57 KB
    LV Broker.zip ‏413 KB

  • LabVIEW Run Time Engine and ActiveX Automation Server

    Hi,
    I have a question related to LabVIEW Run Time Engine and ActiveX Automation Server:
    We have a tool developed in LabVIEW and TestStand. End user interface is a LabVIEW GUI (it's an executable) which executes TestStand sequences. Some TestStand sequences call lower level LabVIEW VIs.
    Everything works fine with LabVIEW installed, but I was wondering if I could run this tool on deployment machine with only LabVIEW run time engine installed. We are using LabVIEW 6.1 and with only the run time engine installed, I get the error message: "Unable to launch the 'LabVIEW.Application' ActiveX automation server ". 
    BTW, we are planning to upgrade the versions soon.
    Is it possible to make things work only with the run time engine?
    Thank you.

    Thanks for the response, Brian.
    I did upgrade to LabVIEW 8.0 and TestStand 3.5. Everything works fine on the development computer where LabVIEW and TestStand is installed. On the target computer in the lab, I installed LV RTE 8.0 and TestStand 3.5, and now when a VI is called in a sequence file, I get the following:
    RunState.PreviousStep.Result.Error.Code  -18002 
    RunState.PreviousStep.Result.Error.Msg  "LabVIEW: The VI is not executable"
    So, the executable opens and works fine (which means that the LV RTE is installed properly), but when a sequence calls a low level VI, it does not make it through.
    comments/suggestions are appreciated. Thanks.

  • NI 5660 Driver DLL Errors when using Teststand 2010 and LabVIEW Run-Time Engine 2010

    This problem seems similar to the post "Resource not found error in executable on developmen​t machine." but I didn't want to repost under that thread because I only happened upon it by chance and none of my searches brought me there... so I made a more descriptive Subject.
    I am working on a system that uses a PXI Chassis with a NI 5600 Downconverter and a NI 5620 high speed digitizer, among other PXI Cards. 
    I inherited working code written in LabVIEW 2010, running with the LabVIEW Run-Time Engine 2010.  The code was using a custom executive and my task was to rewrite the test using TestStand 2010.  I reused the majority of the old code.  The old code used NI-5660 to control the 5600 and 5620.  When I run my sequence using the LV Development System and TestStand, it runs without any issues.  When I change the adapter over to LabVIEW Run-Time Engine 2010, all of my NI5660 VIs become broken due to DLL issues.  It warns that the nipxi5600u​.dll was not initialized correctly.  Many of the errors are associated with the NI Tuner and NI Scope. After this LabVIEW will crash randomly, and the seqeunce will not work in TestStand even when back with the LV Development Adapter.  The only way to recover after this is to restart the computer - TestStand automatically reverts back to the development system, the VIs are no longer broken and the sequence works again. 
    I have all of my VIs associated with a project. After reading a little bit about DLLs and TestStand, I found all of the DLLs in the dependencies section of my project and added them to my TestStand workspace.  I also used Dependency Walker to track down the problems with the nipxi5600u​.dll, the 2 DLL files that it said were not found already existed in the same folder as the original DLL (C:\Windows\System32).  I have also performed a Mass Compile to make sure everything was running in LV 2010.  If I skip the steps involving the 5660, my entire sequence runs fine. 
    The previous code was running with the LabVIEW Run-Time Engine without any issues.  Is there just a step I am missing?  Has anyone seen anything like this before?  I can send screenshots of errors to provide more detail if necessary. 

    I have tried some more things and still can't get it to work.  I have added the VIs mentioned in the Notes On Creating Modulation Executables KB both to the TestStand workspace and the LabVIEW project holding all of my VIs.  This did not change the results. 
    When I try to run my sequence, The first error I get is shown in Error 1445.bmp.  This happens when I try to use the NI 5660 initialize.vi.  If I click ignore, the next error I see is shown in Error -20551.bmp.  When I try to open the VI to look at it, I get the 2 DLL errors shown in Error loading nipxi5600u.bmp and Error loading nidaq32.bmp.  When I close TestStand, I get the error LabVIEW Fatal Error.bmp. 
    Attachments:
    Error1445.JPG ‏164 KB
    Error -20551.JPG ‏174 KB
    Error loading nipxi5600u.JPG ‏9 KB

  • You may not need to install the Run Time Engine...

    I know this has been mentioned before, but after a long search of the archives, I couldn't find the right person to give credit to - sorry!
    If you have a simple exe, you may not need to install the runtime engine on the target machine at all - all you need to do is include some of the engine's files with the exe for it to work. Try it out: copy the following files & folders into the folder containing your exe:
    ..\National Instruments\shared\nicontdt.dll
    ..\National Instruments\shared\nicont.dll
    ..\National Instruments\shared\LabVIEW Run-Time\your_version\everything (including all sub-directories)
    so, using 6.1 as an example, you exe's directory would like something like:
    ..\AppDirectory\MyApp.exe
    ..\AppDirectory\MyApp.ini
    ..\AppDirectory\My_Apps_DLLs,if_any
    ..\AppDirectory\nicontdt.dll
    ..\AppDirectory\nicont.dll
    ..\AppDirectory\lvapp.rsc
    ..\AppDirectory\lvjpeg.dll
    ..\AppDirectory\lvpng.dll
    ..\AppDirectory\lvrt.dll
    ..\AppDirectory\mesa.dll
    ..\AppDirectory\serpdrv
    ..\AppDirectory\models\heaps_of_stuff_in_here
    ..\AppDirectory\errors\more_stuff_in_here
    ..\AppDirectory\script\and_some_bits_in_here_too
    Take all of this data to a machine without LabVIEW or the runtime installed, and try to run the exe - all going well, it will execute without any problems. This exe distribution method can be really useful, especially when distributing autorun presentations on CD-ROMs.
    * DISCLAIMER: as far as I am aware, this method is NOT authorised or supported by NI - use it at your own risk!
    cheers,
    Christopher
    PS: I'd like your feedback: please give this posting a rating
    Christopher G. Relf
    [email protected]
    Int'l Voicemail & Fax: +61 2 8080 8132
    Aust Voicemail & Fax: (02) 8080 8132
    EULA
    1) This is a private email, and although the views expressed within it may not be purely my own, unless specifically referenced I do not suggest they are necessarily associated with anyone else including, but
    not limited to, my employer(s).
    2) This email has NOT been scanned for virii - attached file(s), if any, are provided as is. By copying, detaching and/or opening attached files, you agree to indemnify the sender of such responsibility.
    3) Because e-mail can be altered electronically, the integrity of this communication cannot be guaranteed.
    Copyright © 2004-2015 Christopher G. Relf. Some Rights Reserved. This posting is licensed under a Creative Commons Attribution 2.5 License.

    Yes, this method is not supported. However, this method is good if you wish to write your own installer for a LabVIEW Application. (Note: The method above does not install DataSocket, NI-Reports, or any of the 3D Graph controls.)
    I would still suggest running the LabVIEW Run-time Engine installer so that more than one application can use it.
    Randy Hoskin
    Applications Engineer
    National Instruments
    http://www.ni.com/ask

  • Pdfcreator invokes LabVIEW run-time engine installer!

    Okay, so I'm a desktop tech, know little about LabView, but can at least install it.  We also use pdfcreator on our desktops.  For some reason, however, whenever pdfcreator is used (for ANYTHING, not just LabView stuff), a windows installer fires up, "please wait while windows configures NI LabVIEW Run-Time Engine 7.0."  The installer proceeds, then gets stuck while trying to find the msi.  Well I don't HAVE the proper MSI apparently, because my version is 7.1.1!  When I put in the 7.1.1 Run-Time CD (the only one I have) and point it to the msi it seems to be looking for, it still fails (apparently due to different versions).
    So first, why is pdfcreator invoking this installer in the first place (they seem to have nothing to do with each other!)
    Second, why is the installer looking for the Run-Time for 7.0, instead of 7.1.1?
    Help! 
    Thanks,
    Wiltony

    Well, I fixed it.  I eventually used the NI Software Add/Remove item, and chose "repair" for NI LabVIEW run-time 7.0, which called for the appropriate 7.1.1 device driver discs (strange).  After it completed, everything worked fine.
    Wiltony

  • Is Labview Run-Time engine 2009 SP1 compatible with Windows 8

    I potentially need to install a Labview executable and Run-time engine 2009 on a Windows 8 OS.  From looking at the run-time engine support, it only looks like it only shows windows 7 down to XP.  Does anyone have any experience using Runtime 2009 on Windows 8?

    Hi Awhite144,
    The first version of LabVIEW to officially support Windows 8 is LabVIEW 2012 SP1. That being said, I would expect LabVIEW 2009 to work fine on Windows 8, and if you run into any trouble, feel free to post it here. LabVIEW 2012 SP1 installs a number of older LabVIEW run-time engines (including LabVIEW 2009), so it will install on Windows 8.
    I have not personally used LabVIEW 2009 on Windows 8, maybe if someone else has experience with it they can weigh in, but I expect it to work.
    As an important consideration, I assume you are talking about the full version of Windows 8, not Windows 8 RT. 
    Regards,
    Jeff Peacock 
    Product Support Engineer | LabVIEW R&D | National Instruments 

Maybe you are looking for

  • Remote for iPhone 3GS

    There are lots of discussions out there and lots of sites (via Google search) regarding iPhone apps that turn your phone into a remote. What I'm looking for however (and having the hardest time finding) is a remote to control my iPhone 3GS. In otherw

  • Top_of_page is not working in ALV hierarchy?

    Hi,       I have written following code for top_of_page using event but which is not working...This report is developed for interactive report. Note: passed the it_events into ALV hierarchy functional module. FORM build_event_tab .    CALL FUNCTION '

  • Fill gaps in Dates

    I have a table like this DDL for table: CREATE TABLE TEST1   ID        VARCHAR2(20 BYTE),   HH_START  DATE,   HH_END    DATE Data for table: SET DEFINE OFF; Insert into TEST1    (ID, HH_START, HH_END) Values    ('144813', TO_DATE('01/26/2010 00:00:00

  • Passing parameters to an embedded swf

    Hi all, I'm trying to embed a SWF animation that contains parameters (flashvars). I successfully used this animation in HTML and passed values to these parameters and now I want to embed it in a Flex project. I managed to load and show the animation

  • Setting the count of display in User Admin