Generating a LV Event

I routinely set the controls and read the indictors of a LabVIEW VI through the ActiveX/COM adapter. This has worked fine in the past, but I ran into a snag in my current application.
In this application, I have hundreds of controls so instead of wiring them I am using the Event Structure to detect when a control has changed to invoke the appropriate code for that control. It works fine when the control is manually changed. The problem (which is noted in the LV Manual) is that if the control is changed programatically, such as I do with TestStand, an event is not generated and the code is not invoked.
Is there any work-around for this situation? Is there a way to export the properites of the controls back to TestStand so I could change the Value(signalling) property and generate an event?
Thanks,
Dave

Dave,
I don't think that there is an exported property to do this in LabVIEW's ActiveX Server.
I would be careful in using LabVIEW's ActiveX server from TestStand.  This would require that LabVIEW be present on the machine you are running the sequence on (even after deployment).  The LabVIEW Run-Time Engine does not export an ActiveX server.  If you really needed this functionality on a machine without LabVIEW, I would recommend using a Run-Time Server (basically a simple LabVIEW application that is registered as an ActiveX server), and using that as your method of loading VIs.  However, you would have to change your LabVIEW adapter to use this Run-Time Server as well.
Another solution is to call a LabVIEW VI that gets a reference to the LabVIEW VI on which you wish to change a control.  Since both VIs will be loaded at the same time, you can just specify the VI's name, rather than full path.  You can then get a reference to the Front Panel, iterate through the controls until you find the correct control, and then use a Property Node to change the Value (Signaling) property for the control.  It's not the cleanest solution, but it should serve your needs.  It also does not require that LabVIEW is installed on the machine that is executing the sequence.
Allen P.
TestStand R&D

Similar Messages

  • How do I program the cwCounter control to generate an AcquiredData Event?

    I'm trying to use a general purpose timer on a 6024E DAQ card to generate an AcquiredData event every n MS.
    I can get the timer to run, but I can't seem to get the AcquiredData event to fire. Here is the code I'm using:
    ctrLoop.Reset
    ctrLoop.device = 1
    ctrLoop.Counter = 0
    ctrLoop.ExceptionOnError = True
    ctrLoop.InitialCount = 0
    ctrLoop.MeasurementType = cwctrEvents
    ctrLoop.NMeasurements = 10
    ctrLoop.BufferMode = cwctrContinuous
    ctrLoop.bufferSize = 10
    ctrLoop.UseBuffering = True
    ctrLoop.TimebaseSource = cwctrFrequencyTB
    ctrLoop.TimebaseSignal = 100000
    ctrLoop.Configure
    ctrLoop.Start
    I'm using the following:
    Component works 6.0
    VB 6 with Sp5

    Hello;
    The event you are trying to program is not supported by your hardware. The best way to go about that is to generate a pulse train, on the frequence you want the counter to fire, with one of the counters you have on that board of your; and to have the output of that counter routed to the gate input of one of the counters of a TIO device. The TIO devices support triggered pulse train generations.
    Regards
    Filipe A.
    Applications Engineer
    National Instruments

  • Is it possible to generate a user event when shared variable value change on RT target?

    Hi,
        I wonder if it is possible to generate a user event when a network published shared variable value change?
        Thanks a lot!
        Regards,
        Tom

    Tom,
    I understand not wanting to waster resources on polling but I am not aware that LabVIEW can automatically generate an event on a SV change.
    Maybe a better solution...
    You could implement lower level TCP communication (i.e. have a look at STM - simple messaging protocol) for passing data betweeen RT and PC (instead of using a SV).  You could send a generic command (boolean trigger maybe?) from your RT system when the value of whatever it is the SV is storing has changed.  You can avoid polling on the non-RT system this way.
    Dan

  • How to Generate a ReportError Event

    I'm sure I'm just missing something here.  Our LabVIEW GUI has a registered event Callback for ReportError.  In TestStand I handle errors with SequenceFilePostStepRuntimeError and ProcessModelPostStepRuntimeError callbacks.  I used the error handling example and modified to basically just show a popup with the error message.  My problem is how to generate the ReportError event so our GUI can take the appropriate action.
    I don't see it listed under the given UIMessage event codes.  I can't find it anywhere.  So the questions is where do I generate the ReportError event within TestStand?
    Thanks.

    Hi Sir Mutt,
    If my understanding is correct, you are using LabVIEW as your operator interface to start the Teststand Application and you want to do Teststand Error Handling in LabVIEW. The most common way that this is achieved is through ActiveX Invoke and Property nodes as well as ReportError events. I have attached two screenshot examples of this. Does this sufficiently address your question or did I misinterpret your question?
    Regards,
    Jackie
    DAQ Product Marketing Engineer
    National Instruments
    Attachments:
    ReportError Callback.png ‏8 KB
    Teststand Error Handling.png ‏20 KB

  • Question about generate key press event to system. help plz.

    I am wondering if it is possible to write a java program to generate key press event(not receiving)to the local system so all the other program in the system receive those key press event also. Thanks.

    Hi,
    :. I don't know what exactly you intend to accomplish. But, I have used the following code in order to simulate keys pressing inside a Java application.
          /* - - - Simulates TAB (java.awt.Event)
          EventQueue evtq = Toolkit.getDefaultToolkit().getSystemEventQueue();
          evtq.postEvent( new KeyEvent(this, KeyEvent.KEY_PRESSED,
                          0, 0, KeyEvent.VK_TAB, KeyEvent.CHAR_UNDEFINED) );
          evtq.postEvent( new KeyEvent(this, KeyEvent.KEY_RELEASED,
                          0, 0, KeyEvent.VK_TAB, KeyEvent.CHAR_UNDEFINED) );
          /* - - - Simulates Shift+TAB (java.awt.Event)
          evtq.postEvent( new KeyEvent(this, KeyEvent.KEY_PRESSED, 0,
                          InputEvent.SHIFT_DOWN_MASK, KeyEvent.VK_TAB,
                          KeyEvent.CHAR_UNDEFINED) );
          evtq.postEvent( new KeyEvent(this, KeyEvent.KEY_RELEASED, 0,
                          InputEvent.SHIFT_DOWN_MASK, KeyEvent.VK_TAB,
                          KeyEvent.CHAR_UNDEFINED) );:. However, as far as I know to send keys to the whole OS you have to create a 'Hook' as described inside Win32API documentation. That's for Microsoft Windows naturaly.
    Cheers.
    Roque

  • Intel_iommu1 DEBUG generated a fault event when translating DMA read

    Hello List,
    I'm getting
    "intel_iommu1 DEBUG generated a fault event when translating DMA read on address for PCI(0,0,6). The reason is : The READ field in a page-table entry is clear when DMA read ... pte not found in domid3 for faultin."
    The hardware is IBM X3500 server and OS is Solaris 11.1 Express 64bit.
    I have tried to edit grub with -B immu-enable=false -B intel-iommu=false -v -k -B  but I'm still getting the same message on boot screen.
    I have also tried with intel-iommu=no & intel-iommu=0
    Can someone please help ?
    Thanks.

    hi Cindy,
    I have disabled the Intel virtualization from bios and changed the disk mode to ide. Im still facing the error.
    i have also tried command line options to grub such as intel-iommu=false intel_iommu=false. I tried to replace false with "no" as well as 0 but the error is still there.
    can you help please help me with the exact grub setting?

  • Generate every hour event 2331 for each DP after Software update Deployment Package deletion

    We have an organization build on SCCM 2012 R2 with 270 DPs configured with DP Pulls function. The centralized point contains DP sources available for all DP Pull.
    We have some problems with Windows Update deployment package, and we decide to delete them. We first remove them from all DPs. After more than a month we delete the deployment package. From this day, we see that the SMS_Distribution_Manager service generate
    every hour logs for contacting each of the 270 DPs to ask them for deleting the package.
    Remark: At the time we run the delete, some of the DPs were not connected. After 3 weeks all of them were connected. A month later, the SMS_Distribution_Manager
    generate always these events every hour.
    Each DP responds with a 2331 event that seems OK. Every hour the system begin with two events (2301 and then 2300 for this package, after a 2331 for each
    DP). All these events are also present in the application log of the Event Viewer. After the last DP connection that respond with 2331 event, there are no event that generalize a task for the package to definitively remove it from the database.
    Could anyone help me to correct the system?

    There are no error messages. There are only messages generated in Distribution_manager logs and Event Viewer, showing us server processing and network activity on package that was deleted over 40 days, and that happened every hours. The Microsoft support
    give us directives to delete orphan records in 4 tables
    pkgServers_L,pkgServers_G,PkgStatus_L,PkgStatus_G)
    At this time the correction has positive effect.
    A sample of event generated
    Log Name:      Application
    Source:        SMS Server
    Date:          26.02.2014 09:56:19
    Event ID:      2331
    Task Category: SMS_DISTRIBUTION_MANAGER
    Level:         Information
    Keywords:      Classic
    User:          N/A
    Computer:      wwww.xxxx.yyyy.zzz
    Description:
    On 26.02.2014 09:56:19, component SMS_DISTRIBUTION_MANAGER on computer wwww.xxxx.yyyy.zzz reported:  Distribution Manager successfully removed package "PS100066" from distribution point "["Display=\\aaa.bbb.ccc.dddd\"]MSWNET:["SMS_SITE=xxx"]\\aaa.bbb.ccc.dddd\".
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="SMS Server" />
        <EventID Qualifiers="16384">2331</EventID>
        <Level>4</Level>
        <Task>12</Task>
        <Keywords>0x80000000000000</Keywords>
        <TimeCreated SystemTime="2014-02-26T08:56:19.000000000Z" />
        <EventRecordID>825362</EventRecordID>
        <Channel>Application</Channel>
        <Computer>wwww.xxxx.yyyy.zzz</Computer>
        <Security />
      </System>
      <EventData>
        <Data>PS100066</Data>
        <Data>["Display=\\aaa.bbb.ccc.dddd\"]MSWNET:["SMS_SITE=PS1"]\\aaa.bbb.ccc.dddd\</Data>
        <Data>
        </Data>
        <Data>
        </Data>
        <Data>
        </Data>
        <Data>
        </Data>
        <Data>
        </Data>
        <Data>
        </Data>
        <Data>
        </Data>
        <Data>
        </Data>
        <Data>On 26.02.2014 09:56:19, component SMS_DISTRIBUTION_MANAGER on computer wwww.xxxx.yyyy.zzz reported:  </Data>
        <Data>
        </Data>
      </EventData>
    </Event>
    Regards

  • Generate Listbox Edit Event

    Hello,
    I am using a multicolumn listbox to allow a user to edit and view channel information.  They add new channels and rename them through editing the cell, which I monitor using an event structure.  I added a function to watch for the "tab" key, which will move the edit position over one column, just like users are used to in Excel.  However, I am having trouble, because when they hit the tab key, the "edit cell" event doesn't get generated, and the entry from the column to the left is lost.  Basically, the item names don't get updated unless the user presses "Enter" to accept the edit of the current cell.
    Is there a way to generate the edit event for that listbox, or to otherwise save the edit before moving on to the next column?  I know that tables can accomplish this pretty easily, but I didn't go that way for other reasons that made the development harder.
    Thanks,
    Rob

    Normally, you'll get a value changed event when you hit tab. So if you catch the tab key, and manually skip to the next cell, you don't get that. In fact, you still get the value change event, but only after the table looses focus.I guess you found out about that...
    If you still want to trigger the value change event, you can simply read the value of the table (with a property or local) and put it in a "value (signalling)". Then, the value changed event will be triggered.
    The only difference is that the old value will be the same as the new value. You can get around that by manually buffering the old value in the value event. So you'll have another table with the old value, and update it only when the value changed event is called. If you need the old value, of course.
    Regards,
    Wiebe.

  • JSpinner generates multiple change events

    Having problem with JSpinner generating two change events when using double values in the model. It looks like the number editor formatter is causing an event to be generated before it rounds and after it rounds.
              final JSpinner s = new JSpinner(
                   new SpinnerNumberModel(20.0, 0.0, 100.0, 0.0025));
              s.setEditor(new JSpinner.NumberEditor(s, "###0.000"));
              // When value is changed, need to process certain events.
              s.addChangeListener(new ChangeListener() {
                   public void stateChanged(ChangeEvent event) {
                        System.out.println("New Value:" + s.getValue());
              JFrame f = new JFrame("Test Spinner");
              f.getContentPane().setLayout(new java.awt.BorderLayout());
              f.getContentPane().add(s, java.awt.BorderLayout.CENTER);
              f.setDefaultCloseOperation(JFrame.EXIT_ON_CLOSE);
              f.setSize(331, 254);
              f.setVisible(true);If you modify the editor to use the following format, you can see that the two events are not generated because the formatter does not need to round:
    "###0.000##############"I have to actually modify the model to round the incremented or decremented value to a precision where the formatter will not round the value, which is a pretty messy solution.
    Are there any other workarounds (or solutions) that are a little more elegant?
    Thanks.

    Thanks for the reply.
    This workaround reduces the amount of duplicate events, but I still see double change events that make it through the filter.
    You have to filter events to get the relevant one.
    See :
    http://bugs.sun.com/bugdatabase/view_bug.do?bug_id=476
    5246
    import java.awt.*;
    import java.text.*;
    import javax.swing.*;
    import javax.swing.event.*;
    public class SpinnerEvents{
    JSpinner s;
    JSpinner.NumberEditor jne;
    DecimalFormat dfmt;
    public SpinnerEvents() {
    s = new JSpinner(new SpinnerNumberModel(20.0,
    0.0, 0.0, 100.0, 0.0025));
    jne = new JSpinner.NumberEditor(s, "###0.000");
    dfmt = jne.getFormat();
    s.setEditor(jne);
    // When value is changed, need to process only
    only *relevant event*.
    s.addChangeListener(new ChangeListener() {
    public void stateChanged(ChangeEvent event) {
    double val =
    le val = ((Double)s.getValue()).doubleValue();
    // ignore format event
    if
    if
    if
    if
    (!(String.valueOf(val).equals(dfmt.format(val)))){
    myImportantTask();
    JFrame f = new JFrame("Test Spinner");
    f.getContentPane().setLayout(new
    (new java.awt.BorderLayout());
    f.getContentPane().add(s,
    d(s, java.awt.BorderLayout.NORTH);
    f.setDefaultCloseOperation(JFrame.EXIT_ON_CLOSE);
    f.setSize(300, 300);
    f.setVisible(true);
    void myImportantTask(){
    System.out.println("New Value:" +
    :" + dfmt.format(s.getValue()));
    public static void main(String[] args){
    new SpinnerEvents();

  • File Server Resource Manager 2012 - Fails to generate storage report - Event ID: 8242 and 602

    Installed file server resource manager roll on new 2012 file server.   When I attempt to run a dup report on the local volume, I received an error message: "the report generation task failed with the following errors: Error generating report
    job with task name".  "
    Event ID 8242 and 602 are logged in the event viewer.
    Log Name:      Application
    Source:        SRMSVC
    Date:          6/24/2013 11:11:03 AM
    Event ID:      8242
    Task Category: None
    Level:         Error
    Keywords:      Classic
    User:          N/A
    Computer:      xxxxxxxxxxxxxxxxx
    Description:
    Reporting or classification consumer '' has failed.
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="SRMSVC" />
        <EventID Qualifiers="32772">8242</EventID>
        <Level>2</Level>
        <Task>0</Task>
        <Keywords>0x80000000000000</Keywords>
        <TimeCreated SystemTime="2013-06-24T16:11:03.000000000Z" />
        <EventRecordID>1276</EventRecordID>
        <Channel>Application</Channel>
        <Computer>xxxxxxxxxx</Computer>
        <Security />
      </System>
      <EventData>
        <Data>
        </Data>
        <Data>
    Error-specific details:
       Error: (0x80131501) Unknown error</Data>
        <Binary>2D20436F64653A20434E534D4D4F444330303030303234332D2043616C6C3A20434E534D4D4F444330303030303231322D205049443A202030303030333036302D205449443A202030303030333734382D20434D443A2020433A5C57696E646F77735C73797374656D33325C73726D686F73742E657865202D20557365723A204E616D653A204E5420415554484F524954595C53595354454D2C205349443A532D312D352D313820</Binary>
      </EventData>
    </Event>
    Log Name:      Application
    Source:        SRMREPORTS
    Date:          6/24/2013 11:11:03 AM
    Event ID:      602
    Task Category: None
    Level:         Error
    Keywords:      Classic
    User:          N/A
    Computer:      xxxxxxxxxxxxxxxxxxxx
    Description:
    Error generating report job with the task name ''.
    Context:
     - Exception encountered = System error.
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="SRMREPORTS" />
        <EventID Qualifiers="0">602</EventID>
        <Level>2</Level>
        <Task>0</Task>
        <Keywords>0x80000000000000</Keywords>
        <TimeCreated SystemTime="2013-06-24T16:11:03.000000000Z" />
        <EventRecordID>1277</EventRecordID>
        <Channel>Application</Channel>
        <Computer>xxxxxx</Computer>
        <Security />
      </System>
      <EventData>
        <Data>Error generating report job with the task name ''.
    Context:
     - Exception encountered = System error.
    </Data>
      </EventData>
    </Event>
    When I click on schedule a new report task, I get an error "Class not registered".
    nada

    Hi,
    When we schedule a new job, we add a scheduled task to the c:\windows\tasks folder.
    The scheduled task will contain the following command line
    "c:\WINDOWS\system32\storrept.exe reports generate /scheduled /Task:"FSRM_Report_Task{GUID.......}"
    There is also a folder on the system drive
    C:\StorageReports\Scheduled
    We Also store information in the system volume information folder in the following files:
    c:\system Volume Information\SRM\Settings\ReportSettings.xml (we use .old and .alt extentions}
    c:\system Volume Information\SRM\reports\reportX.xml (where X = an incrementing number set, in writing to these files, we also use .old and .alt extentions}
    When experiencing issues relating to scheduled report jobs, you will want to examine these files and check for NTFS permissions issues on these locations also.
    Make sure you check the volume that you will be running the report on.
    TechNet Subscriber Support in forum |If you have any feedback on our support, please contact [email protected]

  • How to generate SCS=FINISHED event and skip phase STOP_SCS_INITIAL_ADDIN

    Hi all,
    My SapEhpi 'upgrade' from ERP 6.0 to ERP 6.04 EHP4 is stuck in phase STOP_SCS_INITIAL_ADDIN
    This phase stops the SCS with a wrong parsing of the OS stopsap command
    So this phase is stuck, and the ABAP part stops in PHASE GETSYNC_SCS_FINISHED and waits for this Java part to finish and generate an SAPJup SCS event
    My questions:
    1:
    How can I change / override the behaviour / creation of this errourness OS command so it will return without errors?
    2:
    How can I skip this Java phase, since I did its work directly at OS-level?
    i.e. how can I fool the SAPJup that this phase is finished?
    3:
    How can I generate the SAPJup SCS event, so that the ABAP part will continue?
    Kind regards,
    Paul Hoogendoorn

    Hi Sunny,
    The error is caused bij a wrong parsing of the OS command:
    It creates the command: stopsap .. INSTHOST(AMPL-AS01)..
    But it should create stopsap .. INSTHOST('AMPL-AS01')..
    This is an small error in the sapjup, wich will be solved soon by sap on i developer.
    In the meantime: don't use host names wich include a '-' hypen during EHPi upgrade, alltough that are valid host names.
    Kind regards,
    Paul Hoogendoorn

  • How to generate selection change event through code in JTree?

    I am developing an application which downloads the file from other system and adds it into the tree. On selecting any file in the tree I m displaying it's contents. But now i am trying to display the contents of downloaded file as soon as it's download completes. Here i am not getting the way to how to generate the event as the download completes, because i tried that setSelectionPath(TreePath path), but it also don't generates the selection change event. Is there any other way to do so?

    Put null in place of oldLeadSelectionPath. From the API for TreeSelectionEvent:
    protected TreePath     oldLeadSelectionPath:
    leadSelectionPath before the paths changed, may be null.
    I'm at the office and can't try out anything, so please let me know whether that works for you.
    db
    edit Or it may be easier to put all code from your valueChanged (...) override in a new method and invoke that method both from valueChanged (...) and wherever else you need.
    Edited by: Darryl.Burke

  • Generate alerts from event inserted in OM/DW databases

    Hi,
    Is there a existing datasource that is able to read events inserted in OM/DW databases using Microsoft.SystemCenter.CollectEvent and Microsoft.SystemCenter.DataWarehouse.PublishEventData  ?
    Something that would work like Microsoft.SystemCenter.SdkEventProvider but not for events inserted using SDK...
    If such a datasource doesn't exist, I could write a scripted datasource that would query the EventView view in OM database, but I'd rather avoid that.
    The reason why I'm trying to achieve this is that I'm collecting syslog events ( more or less following this article : http://blogs.technet.com/b/omx/archive/2013/01/07/how-to-store-syslog-in-the-scom-data-warehouse.aspx ) and I now need to create alerts
    when a specific event is missing for a
    given target (the targets are already discovered as instances of a custom class with their IP address as a property).
    All targets are sending their syslog events to the same SCOM agent, which explains why I'm unable to simply use a "basic" rule based on syslog datasource -> missing correlator -> alert action (such a rule would need to be targeted at this
    specific agent, thus not allowing me to filter on the IP address property).
    I hope my question was clearly enough explained, if not I'll try to clarify anything you need!
    Thanks,

    Hi 
    you can use System.Mom.BackwardCompatibility.FilteredEvent.DataProvider module to read event in SCOM DB and generate alert, this module is available in System.Mom.BackwardCompatibility.Library.MP .
    Regards 
    sridhar v

  • Cannot generate Account Logon Events (Event ID 4624) in Security Event Log on Server 2008 R2 Domain Controller

    I have configured the Default Domain Controller's policy to log SUCCESS for Account Logon Events in the Server 2008 R2 Domain Controller, but these events are not logging in the Security Event log.
    Default Domain Controllers Policy
    Computer Configuration/Windows Settings/Security Settings/Local Policies/Audit Policies/Audit Account Logon Events = Success.
    What tools can I use to troubleshoot this further? The results of "Auditpol.exe /get /category:*" are below.
    System audit policy
    Category/Subcategory                      Setting
    System
      Security System Extension               No Auditing
      System Integrity                        No Auditing
      IPsec Driver                            No Auditing
      Other System Events                     No Auditing
      Security State Change                   No Auditing
    Logon/Logoff
      Logon                                   No Auditing
      Logoff                                  No Auditing
      Account Lockout                         No Auditing
      IPsec Main Mode                         No Auditing
      IPsec Quick Mode                        No Auditing
      IPsec Extended Mode                     No Auditing
      Special Logon                           No Auditing
      Other Logon/Logoff Events               No Auditing
      Network Policy Server                   No Auditing
    Object Access
      File System                             No Auditing
      Registry                                No Auditing
      Kernel Object                           No Auditing
      SAM                                     No Auditing
      Certification Services                  No Auditing
      Application Generated                   No Auditing
      Handle Manipulation                     No Auditing
      File Share                              No Auditing
      Filtering Platform Packet Drop          No Auditing
      Filtering Platform Connection           No Auditing
      Other Object Access Events              No Auditing
      Detailed File Share                     No Auditing
    Privilege Use
      Sensitive Privilege Use                 No Auditing
      Non Sensitive Privilege Use             No Auditing
      Other Privilege Use Events              No Auditing
    Detailed Tracking
      Process Termination                     No Auditing
      DPAPI Activity                          No Auditing
      RPC Events                              No Auditing
      Process Creation                        No Auditing
    Policy Change
      Audit Policy Change                     No Auditing
      Authentication Policy Change            No Auditing
      Authorization Policy Change             No Auditing
      MPSSVC Rule-Level Policy Change         No Auditing
      Filtering Platform Policy Change        No Auditing
      Other Policy Change Events              No Auditing
    Account Management
      User Account Management                 No Auditing
      Computer Account Management             No Auditing
      Security Group Management               No Auditing
      Distribution Group Management           No Auditing
      Application Group Management            No Auditing
      Other Account Management Events         No Auditing
    DS Access
      Directory Service Changes               No Auditing
      Directory Service Replication           No Auditing
      Detailed Directory Service Replication  No Auditing
      Directory Service Access                No Auditing
    Account Logon
      Kerberos Service Ticket Operations      No Auditing
      Other Account Logon Events              No Auditing
      Kerberos Authentication Service         No Auditing
      Credential Validation                   Success

    Hi Lawrence,
    After configuring the GPO, did we run command gpupdate/force to update the policy immediately on domain controller? Besides, please run command gpresult/h c:\gpreport.html to check if the audit policy
    setting was applied successfully.
    TechNet Subscriber Support
    If you are TechNet Subscription user and have any feedback on our support quality, please send your feedback here.
    Best regards,
    Frank Shen

  • How to generate a keboard event?

    I need to make my application more accessible to keyboard
    only users. This requires me to add an eventlistener for keyboard
    activity and filter the TAB key. I wish to issue a keyboard event
    for the ENTER key when the TAB key is pressed by the user. How can
    I generate the ENTER key please?

    Hi Sir Mutt,
    If my understanding is correct, you are using LabVIEW as your operator interface to start the Teststand Application and you want to do Teststand Error Handling in LabVIEW. The most common way that this is achieved is through ActiveX Invoke and Property nodes as well as ReportError events. I have attached two screenshot examples of this. Does this sufficiently address your question or did I misinterpret your question?
    Regards,
    Jackie
    DAQ Product Marketing Engineer
    National Instruments
    Attachments:
    ReportError Callback.png ‏8 KB
    Teststand Error Handling.png ‏20 KB

  • Generating pre-defined events for system or applications ?

    I would like to write a script of some kind which generates a series of pre-defined events to the system or an active application: such as "a mouse is clicked on position x,y", a "mouse is dragged to position z, w", a "key is pressed", etc. How do I even approach this? And what exactly it should be (probably not an application...)
    Thanks in advance.

    The short answer: it can be done with Applescript.

Maybe you are looking for

  • VEIWING ATTACHMENTS ON THE NOKIA E61

    Does anyone know why my E61 comes up with a message "Unknown Format" when I want to open up attachments e.g. jpegs or pdf's . When I had my Blackberry they opened up with no problems. please answer because I'm going mad!!!!

  • Pagegroup import error message

    How do I troubleshoot this pagegroup import error message [11-FEB-05 03:03:01][ERROR] id = NULL context = NULL user = KLIES ORA-01403: no data found ORA-06512: at "PORTAL.WWUTL_API_IMPORT_PAGEGROUP", line 4296 ORA-01403: no data found What I'm trying

  • How to make a label to be blink?

    Hi , I want to make the check box label blinking and on the forms tools I set the prompt font style to Blink but still doesn't make the label to be blink. Just wonder how to make the label to start blinking? Thanks David

  • Reprinting A form multiple times

    Hi,      I have to reprint a form multiple number of times and each time a print is given     a text COPY # is added in my layout For example: if it is printing first time then nothing is added If 2nd time then Copy 1 IF 3 rd time then COPY 2 and so

  • Puppet Warp - ignore unlinked layer mask

    When I am using puppet warp to transform a layer with an unlinked layer mask, the layer mask does not remain in place, it is being warped along with the layer I am working on. This seems to be a bug since the normal transform tools allow the layers t