Get control and indicator references in individual array

Hi All,
Aim : How to get control and indicators references in two different arrays ?
What I tried :using Pane Reference i got controls but it does include indicator references.
If sombody suggest on this, that would be great.
Thank you.
Solved!
Go to Solution.

What tst said (see attached VI)
Attachments:
Get Indicator references.vi ‏12 KB

Similar Messages

  • Removing the default (View As Icon) for the control and Indicator

    If you remove the default selection View As Icon  for all the control and indicator, it is good for the programmer for easy to visualize the Block diagram code.

    This has already been suggested - http://forums.ni.com/t5/LabVIEW-Idea-Exchange/Default-Option-Do-NOT-Place-Front-Panel-Terminal-as-Icon/idi-p/926871
    Also, note that you can already change it on your computer as mentioned there.

  • Problem in placing controls and indicator on imported pictures

    hi.
    i have a problem in placing controls and indicator on imported pictures on labview front pannel.
    when i place a control or indicator on imported picture ..the control or indicator don't stay at the top of picture but go behind the picture...
    kindly tell me what to do to avoid this....as complete project has been made and now i have to place all controls and indicator of front pannel on to a picture.

    The Front Panel is built in layers. Each new control or decoration you add is placed in the top most layer.
    To change this, select the picture, click the "Reorder" button (that's the rightmost button in the row of buttons on the toolbar, the one with the 2 arrows forming a circle), and select Move to Back. Your picture will be moved to the background and your controls will be in front of it.
    Try to take over the world!

  • Digital control and indicator customisation

    Hi, just a quick simple question. How do u customise a digital control or indicator. Basically i would like them four times as large as they are as standard. Any other help in how to customise different parts of the digitals would be greatly appreciated.
    Thanks Stuart

    The height of a digital control/indicator adjusts itself to the size of the font you choose for the numbers inside. To adjust the size of the increment/decrement buttons, this is done in the control editor. Right click on the control and choose Advanced>Customize. There's a little icon on the tool bar that looks like a wrench. Click on this to enter customize mode and you can change it to look like you want.

  • Get Row and Column info from an Array Cluster

    I have an array with a cluster of 2 elements (string and double). Within my application, I am using the State Machine architecture with an Event Structure. When I click on a element within the cluster array, is there a way to retrieve the row and column? I seen the Coordinates within the Mouse Down event but I don't think that will work.
    Any ideas?
    Solved!
    Go to Solution.

    How To Return the Index of a Mouse-Select Array Element:
    https://decibel.ni.com/content/docs/DOC-6406
    Jean-Marc
    LV2009 and LV2013
    Free PDF Report with iTextSharp

  • How to change numeric control and indicator radix programmat​ically?

    Hi All,
     I need to know how can we change the radix of numeric control as well as numeric indicator while program is running.
    Regards,
    Pramod M G
    Solved!
    Go to Solution.

    Right.  Sorry   Display Format -> Format
    Jim
    You're entirely bonkers. But I'll tell you a secret. All the best people are. ~ Alice

  • I built an application to store de front panel of vi in a JPEG image file, but native labels of controls and indicator are unclear after image capture, some one knows why? I have a working example you can test.

    For some label colors like yellow or green, this defect is almost invisible, but for black color or any dark tone like brown or dark gray after file creation appears unclear labels.

    In more details, JPEG uses lossy compression and is not really suitable for cartoon-like pictures with objects containing high-contrast sharp features such as lines and boxes (as found in front panels). This has to do with the truncation in the 2D cosine transforms which gives you weak ripples near sharp edges, not visible in typical photographs.
    Of course you could set the quality to 100% (optional input) for no truncation with a trade-off of larger files, but it's pretty pointless. JPEG is only meant to be used for photographs.
    PNG is a fantastic format (intended as a GIF replacement), uses lossless compression, and wins in all aspects over jpeg for your intended use. All modern applications can deal with them (e.g. you can insert them into word or powerpo
    int) and any modern browser can display them. (see e.g. the PNG home site for more info).
    LabVIEW Champion . Do more with less code and in less time .

  • Getting error and don't know why - array of objects..

    Image slide[] = new Image[25];
         public SlideShow()
         for(int x = 0; x<= slide.length; x++)
              Image slide[x] = new ImageIcon("slide"+ x +"jpg").getImage();
              add(new ImageViewer(slide[x]));
         }Error:
    SlideShow.java:14: ']' expected
              Image slide[x] = new ImageIcon("slide"+ x +"jpg").getImage();
                          ^
    SlideShow.java:14: illegal start of expression
              Image slide[x] = new ImageIcon("slide"+ x +"jpg").getImage();

    You don't need to declare the type of slide[x]. It is already known to be Image, since you declared slide as Image[]
    Foo[] foos = new Foo[1];
    Foo foos[0] = new Foo(); // WRONG
    foos[0] = new Foo(); // RIGHT

  • Documentation of a control or indicator

    I was documenting a control and indicator using the Properties->Documentation section. In Labview 8.0, you can add new lines into the Description section. In Labview 8.2, I can no longer add new lines in the area. This function fortunately works in the VI documentation. Is there any special codes that will allow me to start new lines, e.g. <B> other </B> will bold the text.

    Use <Shift>-<Enter> (on Windows).

  • Get Control Reference From Connector Pane

    I am trying to get a reference to a control associated with a specific index on the connector pane. I see that there is a method to assign a control to a terminal but not get control from a specific terminal. I know I can list all controls on the connector pane, but this doesn't tell me specifically where they are.
    Edit: I see there are private methods for getting and setting properties which may have this info, but because these are undocumented and they are properties of a VI which is binary, I can't reverse engineer.
    CLA, LabVIEW Versions 2010-2013
    Solved!
    Go to Solution.

    GregFreeman wrote:
    The disconnect I had was that the array of controls that the connector pane property node will return has null refnums for unwired terminals, but there are still references for every terminal on the pane.
    For learning about the terminals on an object, a good tactic is to drop the object on a diagram and select Visible Items > Terminals:
    If you see completely enclosed terminal rects (like in the subVI terminals), then reading the "Terminals[]" property of the object will return all of them, even the null data type ones. So for the subVI, you can see that there are 12 distinct terminal rects, so that's how many terminals the object has. But on the built-in function, there are only 6 enclosed terminal rects. So reading the "Terminals[]" property on the subVI will return 12 items, and reading it on the function will return 6.
    Jacobson wrote:
    Good find on the example VI...
    I wrote it (along with about 400 other VIs in the examples folder), so it was pretty easy to find.
    Darren Nattinger, CLA
    LabVIEW Artisan and Nugget Penman

  • How to create an array with controls and indicators?

    I want to create a scrollable array of control/indicator pairs from a config file.  Something that looks like the attached image.  Of course, I can only create an array that's either either a control or indicator -- not both (the operator should not be able to edit the name or change the state of the LED).  So I guess I need to split the array and have two side-by-side and SOMEHOW link the scrollbars.  But then I have no idea how I can get the control switch states from the array.  Is there an easier way to do what I'm trying to do?
    Attachments:
    New Bitmap Image.JPG ‏11 KB

    Hello,
    Another option would be to use the custom control I built for you, see below.  You can just drop this into an array, it should look like your example (more or less).
    Cheers!
    CLA, CLED, CTD,CPI, LabVIEW Champion
    Platinum Alliance Partner
    Senior Engineer
    Using LV 2013, 2012
    Don't forget Kudos for Good Answers, and Mark a solution if your problem is solved.
    Attachments:
    Custom Switch.ctl ‏8 KB

  • Excel Get ActiveX References​.vi and closing references -- grrr

    I'm new to ActiveX stuff, but eager to learn! 
    The "grrr" in my Subject line is a reference to how I feel about LabVIEW's documentation from time to time.  I'm a dinosaur who came from text-based programming, and did a fair amount of C coding, so sometimes with LabVIEW I'm left with this awful feeling in the pit of my stomach like, "Good grief!  How much memory must LabVIEW be hogging up in the background when I use this vi?" or "What happens to those variables (wires) in that subVI when it completes but doesn't close?  What are their statuses when I come back in the next time?" or "What if I put a lot of elements into that array the first time and then started from element zero the second time and just put in a few?  What has happened with the memroy that was allocated when there were a lot of elements?"
    Today I'm stewing about this "Excel Get ActiveX References.vi," and what happens to the "ActiveX references" it generates each time I call the subVI in which "Excel Get ActiveX References.vi" lives.  I think that at least one of the "ActiveX references" it generates when I call it is of the type Excel._Application.  Then there appears to be an Excel._Workbook, and others.  You see, I've used "Excel Easy Report.vi" to put some data into an Excel spreadsheet, and I want to tell Excel to do a "Save" on the open spreadsheet.  I think ActiveX is the (a) right way to do that, so I'm wading into the ActiveX fray...  But this "Excel Get ActiveX References.vi" says in its help file, "Do not close ActiveX references opened with the Excel Get ActiveX References VI. References must remain open until the report is closed. Otherwise the error 3001 will occur."  Well, these Excel workbooks that get created by my VI could well stay open until after my LabVIEW VI terminates!
    So (finally), here are some of my quesitons:
    1)  When I go through my subVI once, pointing to one workbook, I'll get one set of references "created" or "opened" or whatever you call it when ActiveX references spring into existance.  Now, when I exit the subVI, is it going to automatically try to "close" those ActiveX references?  I don't suppose so, since subVI's stay in memory until the calling VI closes.
    2)  Now, I come back into my subVI a second time.  New workbook gets created, so I get new references.  Ok, fine.  Uh oh!  What happened to those old references?  I suppose that if I didn't somehow save them off, I've probably lost the ability to get them back (maybe I'm wrong, but I don't need them back), but is LabVIEW going to "close" those old references (from previous times through the subVI) because I can't get to them anymore?  Won't that cause the dreaded error 3001?  If LabVIEW is not going to "close" them, what in tarnation happens to them (the old C programmer in me creeping back out)??  Now it's some oddball, orphaned reference, floating out there, hogging memory, waiting to make something crash intermittently and be a debugging nightmare?
    3)  Now, here's the real scary one.  I think I might dodge the "error 3001" bullet in questions 1) and 2), but now let's say the user closes my LabVIEW application while Excel is still open.  All those workbooks are still open.  Presumably, all those ActiveX references I was not supposed to close are still open.  I really hope that LabVIEW is decent enough to close/erase/delete/blow-away (whatever the right word is) all those ActiveX references which were opened/created by "Excel Get ActiveX References.vi" when my program terminates.  But, oh no!  Won't the error 3001 come along then?  I suppose I can just dump it in the shutdown error handling.
    Well, thanks for reading my novel.  I don't know what can be done with LabVIEW documentation to make it more satisfying to folks like me, but perhaps someone can weigh in on all my ActiveX questions here.
    Thank you in advance,
    Steve Brady
    Solved!
    Go to Solution.

    You need to close EVERY ActiveX reference you open.  If you don't you'll end up with some Excel processes running even after LabVIEW exits.  You can see them in Task Manager.
    I, personally, don't like the LabVIEW Report Generation Tool Kit for working with Excel.  I don't think it's flexible enough.  I have a growing library of VIs that I've written that open, manipulate, and close Excel.  Some references I pass from VI to VI and some I close right after I use them.  It all depends on what I'm doing.  If I want to enter read or write data from/to a certain range I'll get the range reference, read or write the data, then close it right away because I have no use for it any more.  On the other hand, when I open Excel or a Workbook I keep the reference until I'm done, which could be later in the program.
    1)  When I go through my subVI once, pointing to one workbook, I'll get one set of references "created" or "opened" or whatever you call it when ActiveX references spring into existence.  Now, when I exit the subVI, is it going to automatically try to "close" those ActiveX references?  I don't suppose so, since subVI's stay in memory until the calling VI closes.
    2)  Now, I come back into my subVI a second time.  New workbook gets created, so I get new references.  Ok, fine.  Uh oh!  What happened to those old references?  I suppose that if I didn't somehow save them off, I've probably lost the ability to get them back (maybe I'm wrong, but I don't need them back), but is LabVIEW going to "close" those old references (from previous times through the subVI) because I can't get to them anymore?  Won't that cause the dreaded error 3001?  If LabVIEW is not going to "close" them, what in tarnation happens to them (the old C programmer in me creeping back out)??  Now it's some oddball, orphaned reference, floating out there, hogging memory, waiting to make something crash intermittently and be a debugging nightmare?
    3)  Now, here's the real scary one.  I think I might dodge the "error 3001" bullet in questions 1) and 2), but now let's say the user closes my LabVIEW application while Excel is still open.  All those workbooks are still open.  Presumably, all those ActiveX references I was not supposed to close are still open.  I really hope that LabVIEW is decent enough to close/erase/delete/blow-away (whatever the right word is) all those ActiveX references which were opened/created by "Excel Get ActiveX References.vi" when my program terminates.  But, oh no!  Won't the error 3001 come along then?  I suppose I can just dump it in the shutdown error handling.
    1)  No, LabVIEW will NOT close those references.  You need to make sure that happens.
    2)  You can save the references in a functional global or use a class but if you're not going to save them close them as soon as you're done with them.
    3)  Your user should not be able to close your LabVIEW application without it going through the shutdown routine you've created for your program.  The ABORT button should never be exposed to the user and you should capture and discard the panel close event so your program ALWAYS shuts down is an orderly fashion.  If you don't you will have fragments of Excel hanging around in your operating system and will have to kill those processes using Task Manager.  That should only be a problem during development, not once deployed.
    I used to program in C and Assembly many moons ago.  You should have seen my first LabVIEW code.  I go back and look at it just so I can see how far I've come in the last 12 years.  I feel your pain.
    Kelly Bersch
    Certified LabVIEW Developer
    Kudos are always welcome

  • I would like to do a program that have one string control and one string indicator, any character that I type in the string control in the same time it will be appear in another string (indicator). How can help me?

    I would like to do a program that have one string control and one string indicator, any character that I type in the string control in the same time it will be appear in another string (indicator). How can help me?

    Why not use an event
    Add a While Loop, inside the loop add the Event Sructure.
    Now in the event structure selecd the String Controls.value change event to
    react
    and the new value inside the event that you get,( connect to the String
    indicator box.
    On Sun, 10 Aug 2003 15:58:47 -0500 (CDT), WiltonFilho wrote:
    > I would like to do a program that have one string control and one
    > string indicator, any character that I type in the string control in
    > the same time it will be appear in another string (indicator). How can
    > help me?
    >
    > I would like to do a program that have one string control and one
    > string indicator, any character that I type in the string control in
    > the same time it will be appear in another string (indicator). How can
    > help me?
    >
    Using M2, Opera's revolutionary e-mail client: http://www.opera.com/m2/

  • TS3899 Whenever I send an email, the person who receives it gets something that says References: and a long list on nonsense to do with Gmail before the actual message appears.

    Whenever I send an email, the person who receives it gets something that says References: and a long list on nonsense to do with Gmail before the actual message appears.
    Here is an example....
    References: <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <CAM-_T=[email protected]> <BLU0 ,[email protected]> <CAM-_T=CAUP+9GyYG-_ecOazo=[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]>
    > Mime-Version: 1.0 (1.0)
    > In-Reply-To: <[email protected]>
    > Content-Type: multipart/alternative;
    > boundary=Apple-Mail-85351E4C-6385-4256-BE9E-27C10517E136
    > Content-Transfer-Encoding: 7bit

    It seems pretty clear to me.
    When you turn off your primary account the only active account the phone can send via is your Gmail account, and that's what you're seeing.
    The question is why do you need to turn off the primary account.. which you answer:
    When that is set up as the primary server and turned on I get a message that says "the recipient was rejected by the server
    That's because your ISP (megalink) is using access controls to manage who sends mail through their mail server. The first thing they're probably doing is using IP address restrictions - essentially saying they'll only relay mail from any machine on their network (including dialup/DSL/etc. customers), but you're not on their network, you're on an AT&T (or Verizon) 3G connection which isn't in their IP address range, and therefore not valid as far as their mail server is concerned.
    The typical solution to this is authentication - by authenticating to their server (via username and password) you identify yourself as a customer and they should relay your messages. So check your phone to ensure that you have authentication enabled for your primary mail account.
    If that fails (e.g. they don't support authenticated SMTP) the next option would be to relay the message through your cell provider's mail server - as an AT&T wireless customer you should be able to relay through AT&T's mail server... likewise for Verizon (or whatever national carrier your iPhone is on). You'll need to check with your carrier's site for the specifics of the mail server address to use.

  • Reference an FPGA Array of Controls

    I am developing a cRIO application that has an array of 23 controls in the FPGA.  The FPGA Interface C API Generator defined them as a name and size.
    typedef enum
       NiFpga_ControlArrayU32_Setpoints = 0x8118,
    } NiFpga_ControlArrayU32;
    typedef enum
       NiFpga_ControlArrayU32Size_Setpoints = 24,
    } NiFpga_ControlArrayU32Size;
    How would I reference the 15th setpoint, as NiFpga_ControlArrayU32[15] or as an offest to 0x8118?
    Solved!
    Go to Solution.

    Hi Paul_Knight,
    When the C headers are generated, there should be one called NiFPGA.h.
    There is a function within this header for reading a U32 array. The function is called NiFpga_ReadArrayU32. Here is some documentation on the various read array functions.
    http://zone.ni.com/reference/en-XX/help/372928G-01/capi/functions_readarray/
    You should be able to read the array values and store them into an array in C. Then you can access them as you would normally within your C program. Hope this helps!
    Robert B
    Applications Engineer
    National Instruments

Maybe you are looking for

  • Can't connect to Windows XP

    Hi, Really need some suggestions. I can connect the Apple TV to my Macbook with no problems using wireless. I cannot get the apple tv to connect to my Windows XP. I have updated to the latest versions of the software. I can ping the apple tv from my

  • Po not displayed

    hi all. i created a po by using the bapi (BAPI_PO_CREATE1). after created there is no mess in bapi error table,  but the po is only in document overview and tables of po. if i use me23n or me22n to display mean it show the error 'this po is doesnot e

  • Mapping IDOC ORDERS05

    Hello. I'm new on idoc mapping so I think that  this is not very difficult for you guys. I'm trying to map ORDERS05's E1EDKA1 and E1EDP01 to an output xml. The problem is that this structures can have more than 1 occurrences and the mapping seems to

  • Achieving thisin obiee

    How to achieve the below function in obiee. Please help add_months(to_date(to_char(Date_Column,'MM')||'-'||:p_year,'MM-YY'),-7) where p_year is a year prompt

  • Iphone 4s doesn't vibrate after installing IOS 8.1

    My Iphone 4s, 32GB lately doesn't seem to vibrate and i suppose it is after the recent update of IOS 8.1 . It does vibrate when i do certain tasks like keying in a wrong password or when i go into Settings>Sound to ensure that vibrate is on for both