Global variable default value

Hi All.
I am running Test Stand 3.5 scripting Labview 7.1 vi's to test batches of populated PCB's (using single pass method). On each initial run of aTest Stand session the test site cables need to be calibrated and the values stored for later use. i.e calibrate the site just the once per session.
I have tried using both a boolean station global and boolean sequence file global and setting them to 'True' when calibration is finished. However the sequence file global defaults to 'False' at the end of each run, (hence cuasing a calibrate each run). and the station global stays 'True' even after the session is ended and Test Stand is closed down. ( hence next session calibration routine is ignored).
Is there a way to either  a) stop the sequence file global defaulting to 'False' after each 'single pass' run yet default to 'False' on Test Stand shutdown. Or b) default the station global to 'False' on Test Stand shutdown? either method would be OK.
Any help would be appreciated.
Thanks
Ian R

Thanks anyway but I just found I need to set the sequence file global properties to 'Shared at run time'.
Cheers

Similar Messages

  • BW Query variable default value put in Crystal report variable question

    Why BW Query variable default value put in Crystal report variable for BO InfoView to open crystal report.
    I using Analyzer to open bw query,variables had default value ,but crystal report can't had variable default value ,and can't search variable  value.
    pho:
    [http://file.itpub.net/f/e38876ad4f6efb7e73980488e7d71f8d/4ae940e9/day_091029/20091029_2b04da1232144feba180OrB23SNvXtoT.gif/p/1.gif]
    [http://file.itpub.net/f/d93ddfe61e0eaf80429726c61f1a02ff/4ae940e9/day_091029/20091029_3211ffe04bf0302fbab5FRKnbwmH80p7.gif/p/BW_QUERY_Crystal.gif]
    Edited by: flying on Oct 29, 2009 8:20 AM

    I Know what to do .
    but Crystal report date variable value are Garbage characters "###".
    PHO:
    [http://file.itpub.net/f/39a8510104476707ae21c945db93ecba/4ae97949/day_091029/20091029_32dcbb7e7d99141483aesJ9KBJHXN0Kj.gif/p/2.gif]

  • How to set variable default value by program?

    Dear all,
    We would like to set a BW variable default value by program (not using query designer).
    Do you have any ABAP sample code for this? I'm really new in ABAP programming.
    we are using BI 7.0
    Thank you for your help!
    Olivier DESFOUR

    Hi Olivier,
    FOllowing is the code which defaults calmonth to first month of the year to current month - 1.
    Data : input1(4) TYPE n,
           input3(2) TYPE n.
    WHEN 'YQV_FD'.
      if i_step = 1.
      input1 = sy-datum+0(4).
      concatenate input1 '01' into l_s_range-low.
      input3 = sy-datum+4(2) - 1.
      concatenate input1 input3 into l_s_range-high.
      l_s_range-sign = 'I'.
      l_s_range-opt = 'BT'.
      APPEND l_s_range TO e_t_range.
      endif.

  • BEx Variable default value does not pass thru to Webi report

    Hi,
    It appears that the integration between BEx and BOBJ Webi does not support default values when the webi report is scheduled.  This means that if Webi/Infoview is the delivery method, than clients require 2 reports.  1 for adhoc and 1 for scheduling.  Is there another way around this so 2 reports are not required?  See SAP Knowledge Base Article  https://websmp130.sap-ag.de/sap(bD1lbiZjPTAwMQ==)/bc/bsp/sno/ui_entry/entry.htm?param=69765F6D6F64653D3030312669765F7361706E6F7465735F6E756D6265723D3030303136363534393826
    Regards,
    Dae Jin

    Hi,
    Yes it is not supported. you can achieve by writing customer exit for this.
    in istep 2,
    check whether the variable value is intial.
    if intial
    pass default value
    if not intial (else)
    dont do any change, just pass the user input to restriction.
    -Sriram

  • Apex 3.2 - Global Variables loosing value!

    Hello Everyone,
    I am using Oracle Apex version 3.2. I am using global variables in my queries.
    I found that some times but not always these global variables loosing their
    value. How I can resolve this issue?
    All replies will be appreciated. Thanks in advance for your replies.
    -Parveen

    Hi, thanks for your answer.
    The king of caché I was talking about is something like this:
    * I get a table record (rowtype) from a query accesing the table by PK.
    * I store the value of my PK and the record I got in PL/SQL and go back to the app.
    * Then, if I need to get another record from my table accesing by PK I compare the PK value I got in memory:
    - It is the same value: return the record (in this way I don't have to query my table).
    - It isn't the same value: query the table with the new value and store the record and the PK value.
    It is easy to do this in applications like Forms or .NET, but can I do it with APEX?
    Thanks.
    Johann Alexander Quintero
    Cali, Colombia.

  • Local variable default value

    Hi
    Just a quick question to get me out of a hole..... I am using local variable to control while loops, and based on a counter value, it turns it on or off. When i probe the value of the actual boolean, it comes up not exectuted, but the local indicator value is true???? is there any way to change this?? i need to to remain false, UNTIL it goes true!
    Cheers
    Peter
    Solved!
    Go to Solution.

    I think that "Ravens" has hit the nail on the head. Using unprotected shared resources (like local variables) in parallel will open the door to race conditions... the bane of any programmers life!
    Here are some useful resources which further explain this concept.
    Using a Local, Global, or Shared Variable in Parallel Loops Can Cause Race Conditions
    http://digital.ni.com/public.nsf/allkb/4F3CC921B4179F9F86256A3B0045CE2D
    Tutorial: Local Variable, Global Variable, and Race Conditions
    http://zone.ni.com/devzone/cda/tut/p/id/7585
    The first link also mentions the producer/consumer articeture and the semaphore. Both great solutions. However, correctly sequencing your source code (using things like error clusters) will help prevent this issue.
    Further more, I wonder if you are initialising your variables??
    You should write a value of false to the variable before you enter the main body of your code. This ensure that the first time you read from the variable it will return a known value (false). If you dont do this, the variable will return what ever was the last value written to it.
    Hope this has been useful.
    Rich R
    Applications Engineer
    National Instruments UK & Ireland

  • Variable default values

    Hi Experts,
    I am using a variable for Date From to Date to in my Query.  I had used the variable 0I_SPL_D which supplies two date Period from / Period To. My requirement is to give default values at run time from beginning of the month to current date of execution.
    So that I can schedule the Query and Broadcast it.
    eg If the report is run today ie on 22.0ct.2009 then both the ends must have the values
    from date 01.10.2009 and
    to date     22.10.2009
    If the report is executed tomorrow the parameters should be
    from date 01.10.2009 and
    to date     23.10.2009
    can any one give any idea
    Thanks
    Shivani

    Hi,
    Try this code.
    WHEN 'Zvariable'
    DATA: from_dy(2) type n,
               from_mo(2) type n,
               from_yr(4) type n,
               from_d(8) type n,
               Date_to TYPE sy-datum.
        IF i_step = 1.
          from_dy(2) ='01'.
          from_mo = sy-datum+4(2).
          from_yr = sy-datum+0(4).
          concatenate from_yr from_mo from_dy into from_d.
          Date_to = sy-datum.
          CLEAR l_s_range.
          MOVE from_d TO l_s_range-low.
          MOVE Date_to TO l_s_range-high.
          MOVE 'I' TO l_s_range-sign.
          MOVE 'BT' TO l_s_range-opt.
          APPEND l_s_range TO e_t_range.
        ENDIF.
    Regards,
    Rk.

  • Can not use Global Variable in Event Structure

    I am using LabVIEW 2009.
    In my LabView project I have a Boolean Global variable called EStop. I can read and write the Global variable. If I double click on the Global variable, it takes me to EStop.vi which includes a Text Button. EStop.vi is part of my Project.
    In one of my VIs, I have an Event Structure. If I go to one of the Event Handlers in that Event Structure and right click and then select Add Event Case, I get a list of possible events. But that list does not include EStop or an EStop events.
    I want to Add an Event Case for EStop: Value Changed.
    Why can't I Add events to an Event Case that include events on Global Variables like value changed?
    How do I add EStop: value changed event to my Event Structure.
    Solved!
    Go to Solution.

    dbaechtel wrote:
    I have many events throughout the system that might need to cause the system to do an Emergency Stop action. So I want ro use a Global variable that is accessible from anywhere in the system. Any action or condition that occurs anywhere in the system can activate the emergency Stop condition by setting the boolean EStop Global variable to True. When the Global bolean variable goes true(value changed), I want to detect that event in an Event Structure and do the actions necessary to accomplish a system Emergency Stop.
    Sorry, I am not familiar with your terminologies. What is your definition of a "system".
    One big VI with many parallel loops?
    Several VIs running in parallel?
    LabVIEW Champion . Do more with less code and in less time .

  • The global variable panel has a menu item under OPERATE called REINITIALI​ZE ALL TO DEFAULT. How can all global variables be reinitiali​zed at to their default values at program startup?

    Each time I restart my application, I would like all global variables to be reset to their default values without having to reset each one individually. Can I do this? If so, how?

    Sure you can do it. Enclosed is a VI which checks all VIs in memory and reinitializes any that are of type Global VI.
    Attachments:
    Reinit_Globals.vi ‏22 KB

  • Can I Access the Value of a Global Variable in a Trigger

    I'm using a Global variable in a Package which i use in the BIU Trigger to populate a column. After assigning the value for that global variable, I run an INSERT in the same package. But I find only the default value of the Global variable populated in the column. Can I use a Global Variable in a Trigger? Is there any way to put in a common value across all the tables in an application for all DMLs of a particular session?

    Helios,
    I'm already having the same setup mentioned in the thread. And I'm doing exactly whats given there. But the issue seems to be something different. I'm assigning the value to the Global Variable in the Package through Apex. Here's the Package Code:
    CREATE OR REPLACE PACKAGE Schema1.SPMS_SECURITY_PKG
    AS
    X_app_user_id NUMBER DEFAULT -1;
    FUNCTION USER_ID RETURN NUMBER;
    END SPMS_SECURITY_PKG;
    CREATE OR REPLACE PACKAGE BODY Schema1.spms_security_pkg
    AS
    FUNCTION user_id
    RETURN NUMBER
    IS
    BEGIN
    -- RAISE_APPLICATION_ERROR(-20001,'USER ID'||'*'||X_app_user_id);
    RETURN NVL (x_app_user_id, -1);
    -- RETURN NVL (sys_context('USERENV', 'CURRENT_USER'), -1);
    EXCEPTION
    WHEN OTHERS
    THEN
    RETURN -1;
    END;
    And Here is the Trigger Code:
    CREATE OR REPLACE TRIGGER Schema1."USER_DETAILS_TRIGGER"
    BEFORE INSERT OR UPDATE
    ON PMS_SICAL.SPMS_USER_DETAILS REFERENCING NEW AS NEW OLD AS OLD
    FOR EACH ROW
    BEGIN
    IF INSERTING
    THEN
    :NEW.created_by := spms_security_pkg.user_id;
    :NEW.created_date := SYSDATE;
    :NEW.START_DATE := SYSDATE;
    ELSIF UPDATING
    THEN
    :NEW.updated_by := SPMS_SECURITY_PKG.X_app_user_id;--spms_security_pkg.user_id;
    :NEW.updated_date := SYSDATE;
    END IF;
    END;
    But I always get -1 in the both in the table after the DMLs.

  • Incorrect value for global variable

    Hi,
    I am facing an issue in a query. In the query there is a Global variable 'Volume type'. In the default value tab of the variable it is given Default value as Litre. In the table RSZGLOBV also i have checked the global variable and there also the 'Internal Characterestic value' is shown as Litre itself. But when I execute the query, it is giving an out put like:
    For the keyfigure Volume,
    If the keyfigure is having some non zero value, it is showing Litre.
    If the kayfigure value is zero, it is showing KG.(which is wrong). For zero also it should display 0.00KG.
    Please help.

    Hi Nitin,
    changing the default within the variable would impact all queries.
    Only if it was an exit variable, you could define within the exit to do different things depending on the query.
    I would suggest the user uses personalization - but this impacts all queries where this variable is used for this user.
    regards
    Cornelia

  • How can I make my mini global variable work in more than the default case?

    Hello, this seems so simple yet does not want to work. I created 2 simple read/write mini vi's and want to use them as global variables. Writing values based on a case selection. This method only seems to work in the default case. Where did I go wrong?  Thanks
    Attachments:
    Curs 0 Y.vi ‏13 KB
    Main.vi ‏19 KB
    Curs 0 X.vi ‏13 KB

    In case 1, you are writing to a second set of subVIs (Curs 1 X.vi vs Curs 0 X.vi). You only read from Curs 0 X.vi, and never from Curs 1 X.vi.
    LabVIEW Champion . Do more with less code and in less time .

  • How do I pass local final variable value to global variable.

    Hi,
    In my code, I need to pass the local final string varibale value to the global variable for further usage. I know final is constant and inside the braces it can't be modified or assigned to other. Help needed in this regard or how do I re-modify the code according to my requirement i.e assigning the final string variable value to the outside of that block.I need the value of final String variable to be available in the process method outside of the specified block.
    class HostConnection{
    public module process(){
         HostKeyVerification hkv = new HostKeyVerification() {
              public boolean verifyHost(String hostname,SshPublicKey key) {
    final String keyfingerprint = key.getFingerprint();               return true;
    Thanks
    Sri                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               

    SriRaj wrote:
    It seems to be by-default all varibales in the inner calss method are Final.This is not true. Try this:
    class SomeClass {
      public void method() {
        Runnable runnable = new Runnable() {
           public void run() {
              int i = 0;  // new inner-class variable
              i = i + 1;
              System.out.println(i);  //prints "1"
    }But you obviously can't do this:
    class SomeClass {
      public void method() {
        Runnable runnable = new Runnable() {
           public void run() {
              int i = 0;  // new inner-class variable
              i = i + 1;
              System.out.println(i);  //prints "1"
        System.out.println(i); //compiler error: "i" is undefined
    }Because you are declaring i in an inner class. If you want to access the value of i outside that inner class, you'd have to do this:
    class SomeClass {
      private int i;
      public void method() {
        Runnable runnable = new Runnable() {
           public void run() {
              int i = 0;  // new inner-class variable
              i = i + 1;
              System.out.println(i);  //prints "1"
              SomeClass.this.i = i;
        System.out.println(i); //no compiler error
    }If this doesn't answer your question, please try to post an actual question, along with your real code, and any compiler errors you are getting, word for word.

  • Default value of BeX customer Exit variable not Displayed in WeBI??

    Hello Experts,
    We are stuck with a problem where WeBI report is created on top of BeX query and we are not able to see the default value of Bex Customer exit variable in WeBI run. Here is the complete scenario:
    1. One restricted KF is created in BeX, restricted with Customer exit variable on net Due date. And this variable is mandatory, ready for input, and Default value in calculated is user exit as current Week's Monday.
    2. So, by default KF data should be restricted to Monday of current week, if user does not change this value.
    3. Now, WeBI report is created on top of this Bex query, and all is working fine, i.e. we are getting variable as Prompt in WeBI, but Default value is not shown while Running the Webi Report.
    So, need your inputs on the same, if default values from BeX in WeBI is supported or not? If yes, why this is happening, and how to resolve it?
    Please notice, the restrcition is in KF only, it is not a separate restrcition on Net Due date in Filter area or in Defualt area of BeX
    and we are on SAP BW 7.1 and BOXI 3.1 SP4.
    Regards,
    Vipul
    Edited by: VIPUL GOYAL on Nov 23, 2011 9:44 PM

    Hi,
    See 1285993 - Support of Customer Exit Variables from BEx query into WebIntelligence via OLAP universe
    WebI will prompt when executed, but the default values calculated by the user exit  - do not appear.
    Note: If the BEx variable has property 'ready for input' set / enabled, then its WebI prompt shows ok, but no default value appears.
    Cause
    This behaviour expected 'by design' (in the context of the product's current limitations) as explained in the online guide below:
    Please refer to Chapter 7, page 44, document link here: http://help.sap.com/businessobject/product_guides/boexir3/en/xi3_sap_olap_universes_en.pdf
    Characteristic variable > processing type > Customer Exit  is "Supported, without user entry"                                                                               
    -->  This should be understood as meaning "User will not be shown a prompt"
    regards,
    H

  • Default Value in Formula Variable - Inconsistent behaviour

    Hi,
    I am facing a very strange issue in a formula variable.
    I had created three formula variables with default values and the user (Power user who has the Bex access) was able to change the default value themselves for two of these variables.
    Now he wants to change all the three, so I have tried to check the issue and changed all the three for testing purpose.
    Now, he is unable to change any of them!!! Sad, now I cant even say that "You dont have the Auth to do so"
    Any clue? Anyone has faced similar issue.
    Any thoughts are highy welcome! Suddenly users wants to get this one URGENTLY, usually he used to access the report once in month. Now he wants to use the same once in half an hour
    We are on BI 7.0 with SP 24
    Any thoughts PLS
    Regards

    hi,
       probably you can refer to SAP Note 1413030 - SAPBWNews NW 7.x BW Add-On Frontend Patch 1300 - GUI 7.10 or maybe  SAP Note 1294382 - SAPBINews NW7.0  BI Add-On Frontend SP900 - GUI 7.1 that might help you in sorting out your problem, plus you can buy more time from the user as well
    regards
    laksh

Maybe you are looking for

  • HP LaserJet 4L printer cannot print from Windows 7

    I currently bought a new computer and wanted to connect my old printer to my new computer.  I bought a new USB cable cord in order to connect my old printer to my new computer.  The model of my printer is HP LaserJet 4L.  However, after I put everyth

  • Urgent - How to pass value to Multiline container element in workflow

    Hi,   I hav a requirement as below... 1) In a Bus. Object, there is a method with a parameter which is Multiline. 2) When I execute it directly from Bus. Object, I am able to populate any no. of lines to the multiline parameter & execute it. It is wo

  • Why is the ios7 update freezing at the "updating iCloud settings" page?

    I have updated to ios7, but when i get to the last few steps, the phone stays on the updating iCloud settings forever till the screen locks and i have to start over. Is this normal? What am i doing wrong or what can i do to fix it?

  • What am I missing?

    I'm a new user of Dreamweaver, stepping in to fix up some problems with my Garden's website. You can see that the side-column links for MEMBERSHIP and SUPPORT US go to the same page. I've found what I assume to be the changeable template for that inf

  • Trying to synch my IPAD and see "Other" memory being used

    Trying to synch my IPAD but see that there is 4.4 GB of memory being used and I have no idea what it relates to so can't determine how/if I can free it up Is there a way to see what it relates to?