Hanling application events in Cpp

Hy all!
Ive written an application in VCpp v6 prof. based on SAP's cpp calculator sample. And id like to handling the sbo application's events (like: when sbo exit i need to terminate my add-on). But unfortunately there is no application event handling in calculator sample. Additionally, i cant find the IApplicationEventPtr object (SDK 6.5) to create my handling...
So, have anyone some idea how could i handling this events in C++?
Thanks.
Ciao!
Lanchèl.

I am sorry I don't have source code for you in c++.  I am sure you have looked at the vb.net source code example in "Catching Events".  It is usually located in SAP Manage\SAP Business One SDK\Samples\COM UI\VB.NET\02.CatchingEvents
The gist is this:
You need to declare a sub that handles SBO_Application_ItemEvent
It should accept the following parameters
ByVal FormUID As String
ByRef pVal As SAPbouiCOM.ItemEvent
ByRef BubbleEvent As Boolean
Description
Occurs when an UI event (click, form load, etc.) takes place on form (or its aggregates) in the SAP Business One application. Use this event to handle UI events on forms and items.
Syntax
Public Event ItemEvent( _
   ByVal FormUID As String, _
   ByVal pVal As ItemEvent, _
   ByRef BubbleEvent As Boolean _
Parameters
FormUID
A string specifying the unique ID of the form on which the event occurs.
pVal
An ItemEvent object holding all the properties that describe the event that is taking place.
BubbleEvent
A boolean value specifying how the application will handle this event. Available only when ItemEvent.BeforeAction=True.
True - Default. The application continues processing this event regularly after returning from the event handler.
False - The application stops handling this event.
So, in a vb.net application, the way you "catch events" is write your own event handling sub that is declared something like this:
Private Sub SBO_Application_ItemEvent(ByVal FormUID As String, ByRef pVal As SAPbouiCOM.ItemEvent, ByRef BubbleEvent As Boolean) Handles SBO_Application.ItemEvent
End Sub
You then go on to evaluate the parameters and take action based on their values.
Sorry I can't give you some c++.  I hope some of this helped.
Good luck!

Similar Messages

  • I wonder to know what is the enterprise solution for windows and application event log management and analyzer

    Hi
    I wonder to know what is the enterprise solution for windows and application event log management and analyzer.
    I have recently research and find two application that seems to be profession ,1-manageengine eventlog analyzer, 2- Solarwinds LEM(Solarwind Log & Event Manager).
    I Want to know the point of view of Microsoft expert and give me their experience and solutions.
    thanks in advance.

    Consider MS System Center 2012.
    Rgds

  • What is the diffrence between sap events and application events

    Hi all,
    what is the diffrence between sap events and application events.Can any one tell me with examples.
    regards,

    Hi,
    Look at this,
    <b>System Events (Default)</b>
    The event is passed to the application server, but does not trigger the PAI. If you have registered an event handler method in your ABAP program for the event (using the SET HANDLER statement), this method is executed on the application server.
    Within the event handler method, you can use the static method SET_NEW_OK_CODE of the global class CL_GUI_CFW to set a function code and trigger the PAI event yourself. After the PAI has been processed, the PBO event of the next screen is triggered.
    The advantage of using this technique is that the event handler method is executed automatically and there are no conflicts with the automatic input checks associated with the screen. The disadvantage is that the contents of the screen fields are not transported to the program, which means that obsolete values could appear on the next screen. You can work around this by using the SET_NEW_OK_CODE method to trigger field transport and the PAI event after the event handler has finished.
    <b>Application Events</b>
    The event is passed to the application server, and triggers the PAI. The function code that you pass contains an internal identifier. You do not have to evaluate this in your ABAP program. Instead, if you want to handle the event, you must include a method call in a PAI dialog module for the static method DISPATCH of the global class CL_GUI_CFW. If you have defined an event handler method in your ABAP program for the event (using the SET HANDLER statement), the DISPATCH method calls it. After the event handler has been processed, control returns to the PAI event after the DISPATCH statement and PAI processing continues.
    The advantage of this is that you can specify yourself the point at which the event is handled, and the contents of the screen fields are transported to the application server beforehand. The disadvantage is that this kind of event handling can lead to conflicts with the automatic input checks on the screen, causing events to be lost.
    Hope u understood.
    Thanks&Regards,
    Ruthra.R

  • How do you add an application event to the Applications Panel

    How do you add an application event to the Applications Panel.
    My previous post referred to .ashx files, and the problem seems that Firefox, by default, does not recognize a .ashx format being read by Adobe Acrobat.
    Therefore there needs to be a way to add Applications and Events into the Applications Panel under Preferences

    domdp wrote:
    ...I have Theme L selected and I get 10 icons along the left side and bottom....
    ...I am thinking I may be limited to 10 icons....
    Gotcha... But actually its limited to 9 icons in the L theme as the Profiles icon is always present. From that screen hit the Menu key to display the bigger list of icons. Arange them so the first 9 icons are the ones you want to see on the L theme.

  • Application events in ALV Grid Control

    Hello,
    Since SET_REGISTERED_EVENTS cannot be used for ALV Grid Control, how do I register a system event (data_changed) as an application event, so that PAI is processed.  I am using ALV grid not tree.
    Thanks

    ALV events can be defined as application events while creating Grid object.
    In addition to parent, Pass one more parameter:-I_APPL_EVENTS = 'X'.
        CREATE OBJECT grid
               EXPORTING
                 i_parent = g_custom_container
                 I_APPL_EVENTS = 'X'.

  • My Application logs "The description of Event ID 0 from MyApp cannot be found" event to application event log

    Hello,
    This is regarding the following event logged by my application (MyApp.exe) to the application event log:
    Log Name:      Application
    Source:        MyApp
    Date:          03/2/2015 12:00:09 PM
    Event ID:      0
    Task Category: None
    Level:         Error
    Keywords:      Classic
    User:          N/A
    Computer:      Rajesh
    Description:
    The description for Event ID 0 from source MyApp cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.
    If the event originated on another computer, the display information had to be saved with the event.
    I have confirmed that the key "EventMessageFile" in HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\services\eventlog\Application\MyApp correctly specifies the "dll" responsible for displaying events.
    I would appreciate suggestions on the above.
    Best Regards,
    Rajesh K Singh

    Hi All,
    can you provide solution on below error.
    The description for Event ID 17052 from source MSSQLSERVER cannot be found
    Severity: 16 Error:0, OS: 0 [Microsoft][SQL Server Native Client 10.0]Unable to complete login process due to delay in opening server connection
    Thanks in advance.
    Vijay
     Check below thread, information is not complete to actually comment what were you doing when you got this message.refer errorlog for more details
    http://social.msdn.microsoft.com/Forums/en-US/9a41ced9-19ad-4c4f-83ac-7e877b699a8f/login-failure-error-in-event-log-daily
    Please mark this reply as answer if it solved your issue or vote as helpful if it helped so that other forum members can benefit from it.
    My TechNet Wiki Articles

  • LocalDrive, remoteDrive error being logged to Windows Application event log

    Post Author: yday
    CA Forum: Data Integration
    Hi all,We are finding the following error messages being constantly logged to the Windows application event log:Event ID: 4096Source: Data Integrator"The error: localDrive: LocalDrive1; localDriveValue:  "andEvent ID: 4096
    Source: Data Integrator
    "The error: remoteDrive: RemoteDrive1; remoteDriveValue: "Another user noted as having the same problem in the old BO Support Forum:http://support.businessobjects.com/forums/message.asp?fid=568&mid=171195  We are also running Data Quality XI R2 (11.5.1.0) on the same server.  This problem has been happening for as long as I can remember.  It does not appear to cause any jobs to fail, but we would like to resolve this to prevent error messages being logged to computer management. Can anyone suggest a solution?  Product: Data Integrator XI R2
    Version: 11.7.0.0
    Patches Applied: None
    Operating System(s): Windows Server 2003 w SP1
    Database(s): Oracle 10gR2
    Error Messages: remoteDrive, localDrive error (as above)Steps to Reproduce: Restart the job server and the error appearsThanks and regards,York DAY

    Post Author: yday
    CA Forum: Data Integration
    Ben,
    I have just installed DI 11.7.2.0 and it is still an issue!  The bug has not been listed in the release notes in either the resolved issues section, or the known issues section.
    Australia support told me it would be fixed in the next service release.  This was well before 11.7.2.0 was released.
    I've opened another support case as I closed the last one, believing it was resolved.  From our perspective, it is not even being shown as a known issue with the product at this stage - so I will be keeping my support issue open this time until I see it is fixed.
    My support case number is 302810798 FYI.
    Rgds,York

  • Registering event as application event for local class inheriting grid clas

    hello all,
         i have a scenario where i have to use many events as system events and one event as a application event for a local class defined which inherits cl_gui_alv_grid can any one tell me how exactly could  i do it.
    Thanks,
    raju N

    Hello Uwe,
    Each of them- "Dynpro" and "Programs" has 2 entries:
    Dynpro     0100 Müller
                   0200 Harryhirsch
    Programs SAPTROX1
                  SAPTRIXTROX
    How can you say that "Programs" has children and "Dynpros" not?
    Regards,
    Christian

  • VB Scripting to monitor application event log based on specific words.

    Hi All,
    I Have written, vb script to monitor application event log based on specific word in the message. when I have included same script in monitor, after running this script at specific time once in day, I am getting run time error in the server, where it
    supposed to run, could you please check the command where I have highlighted in below script.
    Dim VarSize
    Dim objMOMAPI
    Dim objBag
    Set objMOMAPI = CreateObject("MOM.ScriptAPI")
    Set objBag = objMOMAPI.CreateTypedPropertyBag(StateDataType)
    Set objFSO = CreateObject("Scripting.FileSystemObject")
    Const CONVERT_TO_LOCAL_TIME = True
    Set dtmStartDate = CreateObject("WbemScripting.SWbemDateTime")
    dtmStartDate.SetVarDate dateadd("n", -1440, now)' CONVERT_TO_LOCAL_TIME
    strComputer = "."
    Set objWMIService = GetObject("winmgmts:" _
     & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
    Set colLoggedEvents = objWMIService.ExecQuery _
     ("SELECT * FROM Win32_NTLogEvent WHERE Logfile = 'Application' AND " _
     & "EventCode = '100'")
    For Each objEvent in colLoggedEvents
    If InStr(LCase(colLoggedEvents.Message), "Message :Application A3 has been successfully processed for today") Then
    X= "Success"
    end if
    Next
    if X="Success" then
    call objBag.AddValue("State","GOOD")
    call objMOMAPI.Return(objBag)
    wscript.quit()
    Else
    call objBag.AddValue("State","BAD")
    call objMOMAPI.Return(objBag)
    wscript.quit()
    End If

    By programming standards since as long as I can remember the use of the value of a variable to detect its Boolean state has been used.
    Cast your mind back to strongly typed languages, e.g. Pascal.
    I'll cast back to the very early days of the "C" language where all variables could be treated as "bool" without a cast. The is no more strongly type language than "C". "C" practically invented the standards for all modern languages. 
    When I was writin machine language we also used zero as false but many machines only  tested the high bit for truthieness.  The HP machines and Intel allowed a test to aggregate to the sign bit.  Adding that flag to the test alloed tru for
    an numeric value that was non-zero.  A boool test was also used for a negative e switch.  If you study micro language implementation you will find that this hardware design and the companion compiler design is ... well... by design.  It is a
    way of improving the completeness and usefulness of an instruction set.
    Other langauges may require further decoration due to some mistaken desire to be better than perfect. That is like trying to change number theory by renaming addition to be "gunking" and forcing everyone to use multiplication when adding the same number
    more than once.  A Boolean test os a test of the flag bit with to without aggregation.    Even if we test a bit in a word we still mask and aggregate.  It is always the most primitive operation.  It is also the most useful
    operation when you finally realize that it is like an identity in math.
    Use the language features that are designed in. They can help to make code much more flexible and logical.
    By the way, Pascal also treats everything as Boolean when asked to.
    ¯\_(ツ)_/¯

  • IIS 8.5 Idle Time Out Action = Suspend & Global.asax - Are there Application Events for this?

    Hi,
     So, I would like to start using the" Idle Time Out Action - Suspend" for several of my web applications.
    What I would like to know is whether any Application Events occur that I can use so that I know when the WorkProcess enters or exits the suspend state.
    Right now my application does stuff on Application Start and End, and I would like to have that same code executed when the WorkProcess suspends itself and when it comes out of suspend.
    Is this possible?
    Thanks,
    ~Hendel

    Hi Hendel,
    About IIS issue,
    http://forums.iis.net/
    the above forum is where you should post.
    Regards&&Kristin
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • What are application events and system events? what is difference between ?

    what are application events and system events? what is difference between ?

    The Control Framework triggers the event irrespective of the screen flow logic, that is, without processing the PAI and PBO events. These events are called system events. This type of event processing is the default setting.
    ·The Control Framework processes the PAI module after an event. In this case, you must call method CL_GUI_CFW=>DISPATCHto initiate the event handling of ABAP Objects. These events are called application events.
    Application Event : you must first register the events for the control instance and consequently on the frontend.
    like..
    DATA events TYPE cntl_simple_events.
    DATA wa_events TYPE cntl_simple_event.
    1. Using field
    appl_event , define the event as an application event:
    wa_events-appl_event = 'X'.
    System events are passed on irrespective of the flow logic of the relevant screen.
    1. Change the value of field
    wa_events-appl_event in the PBO module:
    wa_events-appl_event = SPACE.
    Edited by: Devi Raju on Jul 1, 2008 1:48 PM

  • Oracle 11g R2 write audit record to application event log in Windows server

    Hi,
    I have a oracle 11g R1 database in windows 2003 server,
    I set the init parameter audit_trail=db,extended,
    but some auditing record still keep writting to windows application log
    Event Type:     Information
    Event Source:     Oracle.test
    Event Category:     None
    Event ID:     34
    Date:          9/7/2011
    Time:          3:36:38 PM
    User:          N/A
    Computer:     test
    Description:
    Audit trail: LENGTH: "226" SESSIONID:[7] "3875588" ENTRYID:[1] "1" USERID:[8] "test" ACTION:[3] "102" RETURNCODE:[1] "0" LOGOFF$PREAD:[1] "1" LOGOFF$LREAD:[3] "755" LOGOFF$LWRITE:[2] "26" LOGOFF$DEAD:[1] "0" DBID:[10] "1613217480" SESSIONCPU:[1] "0".
    Is there any way to disable this?
    Thanks
    Vincent

    oh really, dont you say?
    maybe next time read the whole note, not just the title
    "In 11g these 'logoff by cleanup' audit records are not logged in DBA_AUDIT_TRAIL. The connection record remains as 'logon' record. It is not updated to 'logoff by cleanup'. *In these cases, the log off information like logoff_time, logoff_lread etc are written to an OS audit file as 'logoff by cleanup' audit record.* "

  • Application event linking

    hi all,
          can we link the BPM activity of Xi to events of standard business object like what we do in the R/3 like linking the Sales order events(Created of business object BUS2032) to the activity
    cheers

    No - it doesn't quite work that way.
    You can have a ccBPM trigger a workflow event in an SAP instance e.g. to handle an exception.  But its not a direct link as you describe.
    Standard business objects relate to a single application/instance of SAP.  XI relates to a hetergenous environment spanning multiple SAP and non-SAP instances so a direct link to standard business objects isn't really appropriate.
    Regards,
    Jocelyn

  • Flex mobile:how can view listen to main application events?

    I used to use "this.parentApplication.addEventListener" to listen to main application's events in AIR for desktop. But this seems not working in AIR for Android.
    What is the trick? Or what's the new event mechanism?

    It's now FlexGlobals.topLevelApplication. parentApplication may or may not point to the same thing depending on it's context.

  • Flash Lite applications event handling

    Hi
    i am new to flash lite. I am basically a J2ME person.I just want to know how this scenario is handled in device.
    Flash application is running in the foreground on a Windows mobile device. Suddenly, another application becomes foreground say a call comes then how it will be handled??. Will the flash application knows this information? In midlet we have something like hidenotify shownotify how we can handle this in flashlite ??

    Hi,
    If you're coming from the J2ME world, you'll be disapointed about Flash Lite Capabilities as regards the operating system.
    Flash Lite is running in a virtual machine as you know, but unlike Java, only few methods are available to deal with operating system data/events.
    "Suddenly, another application becomes foreground say a call comes then how it will be handled??"
    As you know Flash was design to run "graphic animations", when Flash Player is put to background, the animation is simply paused.
    However, I believe actionscript code is still processed even in background.
    "Will the flash application knows this information?"
    No way
    "In midlet we have something like hidenotify shownotify how we can handle this in flashlite ??"
    According to the OS you're using, Windows Mobile or Symbian, you can combine Flash Lite with plugins ...
    The basic method is often to communicate with a local server running in dotnet or java and processing operating systems data/events.
    Check :
    Janus-Flash (dead project I think) for Windows Mobile
    Kunerilite for Symbian
    Wait Flash Player 10.1 for mobile devices... along with AIR port, Adobe might offer more OS data/event handling in the Flash Player.

Maybe you are looking for