Hi there,
I'm fairly new to SAP Business One and made a mistake with my last Purchase Order/Goods receipt.
The parcel I had to book in arrived but the invoice had no PO number, so using the Query Manager I found out which Purchase Orders included the product codes. There were a few POs with the same products and I got confused which was which.
When adding the new Goods Receipt I 'copied from' the wrong Purchase Order and saved the updates so now it appears that we have received some of the products from this order, which aren't due for another two months. They are highlighted in grey on the Purchase Order. If I 'copy from' this PO to create the Goods Receipt the lines that I incorrectly updated are no longer visible because according to SAP we have received them so I can't deselect them or make them un-highlighted. Is there anyway to undo the changes so that SAP recognises that we haven't yet received these products?
Any help on rectifying the matter would be much appreciated!
HI
If you have taken Backups before that wrong entry,then you can restore it which will put your database with the previous correct entries...
OR
You have to reverse those GRPO's or Invoice by posting Returns and Credit memos which will make correction to your wrong stock...
Similar Messages
-
Need rounding off value for partial Goods receipt
Hi,
My requirement is that the PO value,PO tax value ,GR value and Invoice value(IR) should get rounded off.
When I am using the PO value which is rounded off in PO, but at the time of posting partial goods receipt the value for the GR/IR clearing or the stock value is not getting rounded off for these G/ls.
What should I do for this to get the rounded off values in GR.
Regards,
GorakshHi Goraksh,
The problem is that the pricing (incl. the rule 17) is not normally called at the time of GR. As Jürgen wrote, the system just uses the "net value" field of the PO.
I have however a "wild" idea. If the price in the PO comes from the info record or from a contract (and not changed manually there), then you can set the "pricing date category" = 5 there, meaning "GR date". This causes the pricing to be called again at the time of GR and your formula 17 will fire.
The side effect of course is that the price that you had in the PO, printed and sent to the vendor will not be binding: if you change the PIR price before the GR, the GR will be posted to the new PIR price, despite the fact that the PO printout showed something else. So the question is if the price printed on the PO is indeed binding in your business case - in many business cases it is the current vendor price that matters for the billing by the vendor, not the one that you prined on the PO. For such business cases you should have had pricing date category 5 anyway...
BR
Raf -
Help needed. Just updated my I phone 4 and lost all my notes, and no I didn't put them in the I cloud. Please help. Need those notes!
You could always check to make sure itunes is updated to 10.7 but im sure gdgmacdude is
right.
thanks
gdgmacdude
Hey dude
are there anymore hardware failure errors u know of
im kinda a novice apple man and could use all the help i can get
capp -
I cannot do a software update, I get as far as System Updates then when I choose it a message appears say "Check for update is not available at this time" but I have not had a system update for a good while now. I am on System version 6.16.211.XT912.Verizon,en,US
Which phone model?
-
Help need my mac pro for school..it has Grey screen..spinning wheel...
I think I have mountain lion OS X....I have done I think almost every suggestion I've seen in discussion boards.
Boot in recovery repaired disk...ok...repair disk permission...all repaired but one warning...I've tried to reinstall lion (without losing data) and it Got all the way to one minute to be done and then the time change back two hours and kept doing this all night long. I haven't done a back up due to no external for time machine.
I hope someone can please help me I've been going crazy for a week now trying to figure this out. I use my computer for school and I'm currently very behind from in my school work thank you
Also I've checked my available space 424.91 free of 750 gigs....disk is verifiedWelcome to the Apple Support Communities
Try holding the Shift key while your Mac is starting to start into safe mode. Then, after starting in safe mode, open Finder, select Go menu (on the menu bar) > Go to Folder, and type /Library/StartupItems. Then, empty this folder and restart the Mac.
If your Mac starts after doing this, it was a problem with a third-party app that starts automatically when you turn on the computer. It won't start automatically anymore after doing that -
Quantity Reliability - evaluate supplier for each good receipt
Vendor Evaluation - Quantity Reliability
A vendor's score is updated in the statistics file when a purchase order or scheduling agreement is closed.
I would like to know if exists a standard configuration to update in the statistics file for each good receipt through MIGO transaction. Because some scheduling agreements will never be closed.
I need to know if my problem have a standard configuration or I will have to request a SAP consultant to do a customization?
Thanks
Rafael Carlos de OliveiraHai Danny Gan
Try This
SELECT T1.DocDate AS 'Posting Date', T1.DocNum AS 'Document Number', T1.U_CUSTPONO AS 'Customer PO No', T0.ItemCode AS 'Item No.', T1. U_DONO AS 'Supplier DO NO.' ,T0.Dscription AS 'Item/Service Description', T0.Quantity AS 'Quantity', T0.unitMsr AS 'UOM' , T0.WhsCode AS 'WhseCode'
FROM dbo.PDN1 T0 INNER JOIN dbo.OPDN T1 ON T1.DocEntry = T0.DocEntry WHERE T1.DocDate>=%0 AND T1.DocDate <=%1 and T0.TargetType <> 21 ORDER BY T1.DocDate
Edited by: Prasanna s on Apr 7, 2009 1:28 PM -
Early Inspection for a Goods Receipt for production order
Dear Experts,
This is with respect Early Inspection for a Goods Receipt for inspction type 04.( 03 is also active in material master)
We made partial confirmation 250 qty for production order using t code co11n ( total qty of production order is 1000).
made the usage decision with an acceptance and posted all open stocks. to unrestricted.
Now in second partial confirmation prodn order of 250 qty was made . This suppose to be rejected . but sytem will add this 250 qty directly to unrestricted stock . how to over come this .
Regards
SandeepDon't make the UD until all stock has been receipted?
You basically approved the batch. So why wouldn't the system put the stock to unrestricted?
Why would you make a UD when you still have stock to be posted anyway? You can post stock without without making a UD so why not just post some if you need it, and wait on making the UD?
Craig -
Tracking of Inbound Delivery reference for a Goods Receipt/GR line item
Hi,
We are posting goods receipt with reference Inbound delivery. We need to track Inbound delivery reference for a Goods Receipt/Goods Receipt line item.
Is it possible? What will be correct way to do this?
Regards,
MakarandHi Makarand ,
You may try with Table MKPF.
Goto SE16 and enter the above table to get the required data.
Regards
Ramesh Ch -
Document type assigned for other goods receipts(MB1C)is WA why?
Hi,
Document type assigned for other goods receipts(MB1C)is WA why?
ThanksDocument type for Goods Receipt is WE but I found in standard(Default) system it is assigned WA?
Can anyone help me on this?
Thanks -
BDC program for Other Goods receipts
Hi all,
I need BDC program for Other goods receipts,
I have data in excel like material, batch id, qty, actual width, length, plant etc. i want to upload this in one short based on the movement type.
Thanks in advance.
ShankarHi MP Shankar,
This is a sample BDC program .Use the format to develop your own BDC program.First record your trasnaction and use that recorded program here.Pass your filename here.
SELECTION-SCREEN BEGIN OF BLOCK b1 WITH FRAME TITLE text-001.
PARAMETERS: p_ifile TYPE dxfile-filename.
SELECTION-SCREEN END OF BLOCK b1.
SELECTION-SCREEN BEGIN OF BLOCK b3 WITH FRAME TITLE text-002.
PARAMETERS: p_sess RADIOBUTTON GROUP g3 "create session
DEFAULT 'X' USER-COMMAND bdc,
p_ctu RADIOBUTTON GROUP g3. "call transaction
SELECTION-SCREEN END OF BLOCK b3.
DATA : BEGIN OF itab OCCURS 0,
str TYPE string,
END OF itab,
l_file TYPE string,
t_bdcdata TYPE STANDARD TABLE OF bdcdata,
wa_bdcdata LIKE LINE OF t_bdcdata.
AT SELECTION SCREEN ON VALUE REQUEST
Value request for the filename.
AT SELECTION-SCREEN ON VALUE-REQUEST FOR p_ifile.
PERFORM help_input_file.
START-OF-SELECTION.
CLEAR l_file.
l_file = p_ifile.
CALL FUNCTION 'GUI_UPLOAD'
EXPORTING
filename = l_file
filetype = 'ASC'
TABLES
data_tab = itab
EXCEPTIONS
file_open_error = 1
file_read_error = 2
no_batch = 3
gui_refuse_filetransfer = 4
invalid_type = 5
no_authority = 6
unknown_error = 7
bad_data_format = 8
header_not_allowed = 9
separator_not_allowed = 10
header_too_long = 11
unknown_dp_error = 12
access_denied = 13
dp_out_of_memory = 14
disk_full = 15
dp_timeout = 16
OTHERS = 17.
*Start new session
IF p_sess = 'X'.
PERFORM bdc_open.
ENDIF.
LOOP AT itab.
PERFORM creat_batch_input.
PERFORM bdc_insert.
IF p_ctu = 'X'.
CALL TRANSACTION 'SE38' USING t_bdcdata MODE 'A'.
ENDIF.
ENDLOOP.
IF p_sess = 'X'.
PERFORM bdc_close .
ENDIF.
*& Form bdc_open
text
--> p1 text
<-- p2 text
FORM bdc_open .
CALL FUNCTION 'BDC_OPEN_GROUP'
EXPORTING
client = sy-mandt
group = 'ZMUK'
user = sy-uname
EXCEPTIONS
client_invalid = 1
destination_invalid = 2
group_invalid = 3
group_is_locked = 4
holddate_invalid = 5
internal_error = 6
queue_error = 7
running = 8
system_lock_error = 9
user_invalid = 10
OTHERS = 11.
ENDFORM. " bdc_open
*& Form creat_batch_input
text
--> p1 text
<-- p2 text
FORM creat_batch_input .
use your own recorded program here.
PERFORM bdc_dynpro USING 'SAPLWBABAP' '0100'.
PERFORM bdc_field USING 'BDC_OKCODE'
'=STRT'.
PERFORM bdc_field USING 'RS38M-PROGRAMM'
itab-str.
PERFORM bdc_field USING 'RS38M-FUNC_EDIT'
'X'.
PERFORM bdc_dynpro USING 'SAPLSLVC_FULLSCREEN' '0500'.
PERFORM bdc_field USING 'BDC_OKCODE'
'=&F03'.
PERFORM bdc_dynpro USING 'SAPLWBABAP' '0100'.
PERFORM bdc_field USING 'BDC_OKCODE'
'=BACK'.
PERFORM bdc_field USING 'RS38M-PROGRAMM'
itab-str.
PERFORM bdc_field USING 'RS38M-FUNC_EDIT'
'X'.
ENDFORM. " creat_batch_input
*& Form bdc_insert
text
--> p1 text
<-- p2 text
FORM bdc_insert .
CALL FUNCTION 'BDC_INSERT'
EXPORTING
tcode = 'SE38'
TABLES
dynprotab = t_bdcdata
EXCEPTIONS
internal_error = 1
not_open = 2
queue_error = 3
tcode_invalid = 4
printing_invalid = 5
posting_invalid = 6
OTHERS = 7.
ENDFORM. " bdc_insert
*& Form bdc_dynpro
text
-->P_0168 text
-->P_0169 text
FORM bdc_dynpro USING p_program TYPE any
p_dynpro TYPE any.
CLEAR wa_bdcdata.
wa_bdcdata-program = p_program.
wa_bdcdata-dynpro = p_dynpro.
wa_bdcdata-dynbegin = 'X'.
APPEND wa_bdcdata TO t_bdcdata.
ENDFORM. " bdc_dynpro
*& Form bdc_field
text
-->P_0179 text
-->P_0180 text
FORM bdc_field USING p_fnam TYPE any
p_fval TYPE any.
CLEAR wa_bdcdata.
wa_bdcdata-fnam = p_fnam.
wa_bdcdata-fval = p_fval.
CONDENSE wa_bdcdata-fval.
APPEND wa_bdcdata TO t_bdcdata.
ENDFORM. " bdc_field
*& Form bdc_close
text
--> p1 text
<-- p2 text
FORM bdc_close .
CALL FUNCTION 'BDC_CLOSE_GROUP'
EXCEPTIONS
not_open = 1
queue_error = 2
OTHERS = 3.
ENDFORM. " bdc_close
*& Form help_input_file
text
--> p1 text
<-- p2 text
FORM help_input_file .
DATA: lt_file_table TYPE filetable,
la_file_table LIKE LINE OF lt_file_table,
l_rc TYPE i,
l_pcdsn TYPE cffile-filename.
REFRESH lt_file_table.
CLEAR la_file_table.
CALL METHOD cl_gui_frontend_services=>file_open_dialog
CHANGING
file_table = lt_file_table
rc = l_rc.
READ TABLE lt_file_table INTO la_file_table INDEX 1.
l_pcdsn = la_file_table-filename.
MOVE l_pcdsn TO p_ifile.
ENDFORM. " help_input_file -
Fright should be constant for all goods Receipts irrespective of no. of GR
Hi,
I have a fright condition for example 100/- and it is constant for all GRs, means the fright should be constant for all goods Receipts irrespective of no. of GRs it is 100/- only. Can you please tell what is setting for this in condition type or any suggestion?
SubrahmanyamHI
do as stated above reply
use condition FRB1 it is for fixed value freight
or keep condition record in inforecord for vendor and material
or
give limits for condition it is just below define condition
regards
kunal -
Help needed in PL/SQL for updating the column for multiple records
Hi,
I am new to PL/SQL and need some help. What is the most effiecient way to update some field in a table as I may need to update thousands of records. I have a coulmn groupid can have multiple records tied to it. All the records attached to some groupid have a priority field also.
How can I update the prorityfield value for all the groupids in a profiecient way. Here is a sample data
GroupId Priority
1 1
1 2
1 3
1 4
1 5
2 1
2 2
2 3
3 1Here I have three groups 1, 2, 3. Now if any group contains only one record the priority remains same e.g. groupid=3 on top. If any group contains more than one record e.g. groupid=1 & 2 I want to re-arrange the priority fields e.g. If I want to update groupid=1 now if I change the priority of 2 to 5 (make it the last) I want to rearrange the remaing records priority i.e. if 2 becomes 5 as I have 5 rows for groupid=1 then 5 becomes 4, 4 becomes 3, 3 becomes 2 and 1 remains the same.
Same wya if I want to make the priority 1 to 3 for groupid=2 then need 2 to become 1 and 3 to become 2 etc....
Any help is appreciated.
ThanksHi,
You don't need PL/SQL to do this (though you can put the following in PL/SQL if you want to):
UPDATE table_x
SET priority = CASE
WHEN groupid = 1
AND priority = 2
THEN 5
WHEN groupod = 1
AND priority BETWEEN 3 AND 5
THEN priority - 1
WHEN groupid = 2
THEN
CASE
WHEN prioity = 1
THEN 3
ELSE priority - 1
END
END
WHERE groupId IN (1, 2)
AND ( priority BETWEEN 2 AND 5
OR groupid = 2
);There are lots of different techniques that can reduce your coidng: for example, the nested CASE statement used for groupid=2 above.
You could do several smaller UPDATEs (for example, one just for groupid=1). Execution will be slower, but coding and testing will be faster.
You could make the "magic numbers" 2 (for groupid=1) and 1 (for groupid=2) variables, even outside of PL/SQL.
If you need more help, post the information that Satyaki requested. -
Desperate help needed to configure WVC210 for remote access?
Hi, I'm new and desperately need some help on setting up my WVC210 for remote access.
I manage to setup and see images from my WVC210 using my home LAN via both wired and also wireless.
I have 2 questions:
(a) for wireless connection, i only manage to get connection to my WVC210 if i disable the wireless security from my router. But that means i'm opening my wireless LAN to everyone. How can i still get connection to the camera if i enable the wireless security from my router. (FYI: my router is 2Wire ADSL from Singnet Mio)
(b) how can i get connection to my WVC210 from outside or in my office? I type in the camera Fixed IP address (displayed on the front screen) on the web browser, by it shows a error page. Is there some setting that i might need to adjust ?
Pls kindly help me
Thank you.Bernard,
For Item (2) is there any difference between the camera built-in dyndns updater versus the software updater? I am under the impression that the software updater is easier to manage.
The biggest difference for you is that the camera always stays at the same location, and the laptop goes with you. Every time you access the internet from a different location with the laptop the software updater is sending the new IP address to dyndns.com. This causes you to lose access to your camera because the FQDN doesn't point to your home IP address anymore. Once the dyndns credentials are in the camera (or router) there is no management needed. The device will automatically update dyndns.com with your new IP address as it changes, and you do not need to do anything.
For Item (3), are you saying port forward 1025 is it for the 2nd camera only or for both? Or is it 2nd camera use 1025 and first camera use 8080?
Here's an example of what I mean:
Camera 1: 192.168.1.210 port 1024. In router, forward port 1024 to 192.168.1.210
Local Access: http://192.168.1.210:1024
Remote Access: http://bernards210.dyndns.org:1024 (Example)
Camera 2: 192.168.1.211 port 1025. In router, forward port 1025 to 192.168.1.211
Local Access: http://192.168.1.211:1025
Remote Access: http://bernards210.dyndns.org:1025 (Example)
Camera 3: 192.168.1.212 port 1026. In router, forward port 1026 to 192.168.1.212
Local Access: http://192.168.1.212:1026
Remote Access: http://bernards210.dyndns.org:1026 (Example)
to access the 2 camera outside, do i have to have another dyndns host name or can i use the current one for both camera?
As you can see in the above example, the dyndns name remains the same for remote access to all three cameras. The only change is the port number at the end. Your router will translate the port number to the IP address that the port is forwarded to, allowing you to select the camera that you wish to view by changing the port number in the address.
I was actually thinking that the camera web browser can show 2 camera at the same time. Is it possible?
No. Each browser window will display a single camera. You can however opens multiple instances of your browser to allow viewing of more than one camera simultaneously. A better solution is to install the Video Monitoring Software that is included with the camera which allows you to view multiple cameras in the same window. -
I'm trying to deploy the 10.0.1 update to my corporation. I need the multiple language update. When I go to the Downloads site for Adobe Reader, the update for multiple languages languages is the exact same file as the update for Tier 1 languages. I've called (yes, and actually held on long enough to speak to someone) twice asking for clarification on the files. The first time I was told this would be escalated to the web team and to call back. Over a week later no change to the files on the download site so I had to call in again and go through the same painful process to get the person on the phone to understand the problem. Has anyone already gone through this and determined whether that update is Tier 1 or multiple languages? Thank you very much.
http://www.adobe.com/support/downloads/product.jsp?product=10&platform=Windows
You need to select an appropriate Patch (Tier1 through Tier4) for the Reader(s) installed on you system(s) -
Why would the SPD workflow .xsn file are all needing to be updated for some reason?
I have had more then a few workflows all of sudden need to be recompiled and published, and what I'm noticing is that I'm being told with an error message that the .xsn file needs to be updated.
any idea why the infopath form for the workflow would need to be updated?http://social.technet.microsoft.com/Forums/office/en-US/52a30356-d680-41ae-b179-0938eb9101a5/approval-process-form-marked-as-needs-update?forum=sharepointcustomizationprevious
So the fields that are changed may not be on your list. This could be a lookup to a different list or something like that.
The SharePoint logs will contains the details of which field is the problem. You might want to use ULS Viewer:
http://www.microsoft.com/en-us/download/details.aspx?id=44020
Simply start ULS viewer just before you load the form.
Maybe you are looking for
-
Error message when trying to upgrade to the new mac os update
today in the afternoon i was updating to the new version and then i got the grey screen and i restarted like it tells me in the message and then i had some serious error and the imac wasnt loading so i called support and he helped me reinstall the os
-
hi, can anyone please help me with the following: The description for Event ID 8306 from source Microsoft-SharePoint Products-SharePoint Foundation cannot be found. Either the component that raises this event is not installed on your local computer o
-
Microsoft Teredo tunneling adapter #2 is not working
Hi, i'm having problems with "microsoft teredo tunneling adapter #2". I've tried to fix it, but it keeps on saying that it's not working.When i set the tcpip6/parameters value to 0 it only fixed the teredo tunneling adapter but the teredo tunneling a
-
Upgraded to LR5.7 and PS Elements 13. Using a Solid State Drive which is becoming Full! Can I remove older versions of these programs without affecting the functionality of the new programs?
-
Does my ipad with retina display have visual out?
I'm trying to get my ipad to play through my tv. I have a lightning to 30-pin adapter and composite AV cable. All I get is audio! The manual says to make sure my ipad is set to video signal out which after looking online I found out is supposed to be