Hi friends i have doubt on collect statement.

i have some problem with matnr which is repeating no.of times. so i tried using collect and selected some of the fields to collect. Now i need to collect those collected elements in to internal table and need to display those fields in an ouput. for example.
loop at sumtab.
matnr type s886-matnr,
avg1 type p decimals 3,
total type p decimals 3,
endloop.
and now using loop  i am collecting. these fields using my itab.
loop at itab.
move-corresponding itab to sumtab.
collect sumtab.
clear sumtab.
endloop.
***here itab contains no.of other fields like qty,stock etc.
so after here i am using ALV to display the itab.
my problem is how to make SUMTAB fields tobe moved in itab.

Hi Kalyan,
   The collect statement works like this . (ex)
data: begin of itab occurs 0,
      name(10) type c,
      value(4) type n,
      end of itab.
itab-name = 'JACK'.
itab-value = 100.
append itab.
itab-name = 'PAT'.
itab-value = 200.
append itab.
itab-name = 'JACK'.
itab-value = 200.
append itab.
sort itab.
loop itab.
collect itab.
write: / itab-name, itab-value.
endloop.
<b>o/p:</b>
JACK 300
PAT  200

Similar Messages

  • Hi friends i have doubt on select statement

    hi friends, i am using one ztable which contains around 60 fields. i would like to consider in to itab around 52 fields. for this i am using "select * from ztable into itab....". can u please suggest me how can i improve by selecting all the fields and without reducing performance.

    Declare as below:
    Select-options: s_matnr FOR mara-matnr.
    Data: Begin of itab.
      INCLUDE STRUCTURE mara.
    Data: End of itab.
    Clear itab.
    Refresh itab.
    Select * from mara
             into table itab
             where matnr = s_matnr.
    if sy-subrc = 0.
    SORT itab.
    endif.
    OR if you are selecting based on some internal table then use
    FO ALL ENTRIES IN itab1.
    Hope this helps you, it will also improve your performance.
    Reward points and close the thread else revert back.

  • I have doubt in Read statement

    Hi All.
    I have doubt in Read statement .i need to convert following select statement  as read statement .how can i change help me.
    IF p_field1 IS  INITIAL
         AND p_field2 IS INITIAL
         AND p_field3 IS INITIAL
         AND p_field4 IS INITIAL
         AND p_field5 IS INITIAL.
        SELECT *
              FROM zdbt
               INTO TABLE itab
               WHERE field5 = p_field5
               ORDER BY PRIMARY KEY.
        IF sy-subrc <> 0.
          MESSAGE s035.
        ENDIF.
      ENDIF.
    regards,
    Jay.

    hi
    The READ statement is as below:
    When u have a table already with values and to improve the performance u need to use this.
    Reading Lines of Tables
    To read a single line of any table, use the statement:
    READ TABLE <itab> <key> <result>.
    For the statement to be valid for any kind of table, you must specify the entry using the key and
    not the index. You specify the key in the <key> part of the statement. The <result> part can
    specify a further processing option for the line that is retrieved.
    If the system finds an entry, it sets SY-SUBRC to zero, if not, it takes the value 4, as long as it is
    not influenced by one of the possible additions. If the internal table is an index table, SY-TABIX
    is set to the index of the line retrieved. If the table has a non-unique key and there are duplicate
    entries, the first entry is read.
    Thanks
    Shiva

  • Hi friends i have doubt in dialog programming.

    i am desiging the screen using table control. which is suppose to accept unit of measure as 'car' means carton, kg, and so on. so if i enter numerics it should not accept. can anybody tell me how  can i restrict the user to enter only alphanumerics. thanks in advance.

    Hello,
    U can use the system table field ABCDE for checking if it has only alphabets.
    system field == SY-ABCDE
    Regards
    Anurag

  • Hi friends i have doubt on set cursor.

    i am using dialog programming. here in the first text field i am auto generating the number, so user should only suppose to enter the values for other repective fields only.but in execution the cursor is positioning at the first field. it should start from the second and so on.
    i tried using SET CURSOR FIELD F2. but tbe result is same. please provide me guidence on this.

    Hi,
    In the PBO of the dialog module,write the following code :
    SET CURSOR FIELD `FIELD2`.
    Remember the FIELD2 is the name assigned to the textbox of the screen.
    Best regards,
    Prashant
    PS : Please reward all helpful answers

  • Reg: Collect statement in internal table

    Hi,
       Can any one tell me wether we can use the collect statement in an internal table which has no header line
    if it can be used can anyone please send me a sample snippet
    Thanks In ADVANCE
    Guhapriyan Subrahmanyam

    Hi Guhapriyan,
    I have used the collect statement in the way as shown..
    DATA : BEGIN of I_ALLOCATIONS OCCURS 0,
            PSPNR LIKE PRPS-PSPNR,
            PSPID LIKE PROJ-PSPID,
            PSPHI LIKE PRPS-PSPHI,
            POST1 LIKE PROJ-POST1,
            ZZLOB LIKE PROJ-ZZLOB,
            WERKS LIKE PROJ-WERKS,
            SOBID LIKE HRP1001-SOBID,
            OBJID LIKE HRP1001-OBJID,
            BEGDA LIKE HRP1001-BEGDA,
            ENDDA LIKE HRP1001-ENDDA,
            PROZT LIKE HRP1001-PROZT,
            LOB   LIKE HRP1000-STEXT,
            TEMP  TYPE P decimals 2,
            TYPE(3),
            ZROLE LIKE PA0001-ZROLE,
            HOLID TYPE P decimals 2,
            LEAVE TYPE P decimals 2,
            DAYS  TYPE P decimals 2,
           END of I_ALLOCATIONS.
    DATA:  I_ALLOCATION LIKE I_ALLOCATIONS OCCURS 0 WITH HEADER LINE.
    ************Populate I_ALLOCATIONS **************
    LOOP AT I_ALLOCATIONS.
        COLLECT I_ALLOCATIONS INTO I_ALLOCATION.
    ENDLOOP.
    Actually i had requirement like u, but this one is rather simple...
    Get the required data in an I_Table which dont require Header line..
    Later on collect this particular I_Table in other I_Table1 with the Header Line...
    Regards,
    Abhishek

  • Hi i have some problem with collect statement.

    hi when i am using collect statement and whn ever any field is modified it is getting doubled and showing doubled value. may i knoe what would be problem.

    Hai Kumar
    Go through the following Collect Syntax
    COLLECT
    Basic form
    COLLECT [wa INTO] itab.
    Addition
    ... SORTED BY f
    Effect
    COLLECT is used to create unique or compressed datsets. The key fields are the default key fields of the internal table itab .
    If you use only COLLECT to fill an internal table, COLLECT makes sure that the internal table does not contain two entries with the same default key fields.
    If, besides its default key fields, the internal table contains number fields (see also ABAP/4 number types ), the contents of these number fields are added together if the internal table already contains an entry with the same key fields.
    If the default key of an internal table processed with COLLECT is blank, all the values are added up in the first table line.
    If you specify wa INTO , the entry to be processed is taken from the explicitly specified work area wa . If not, it comes from the header line of the internal table itab .
    After COLLECT , the system field SY-TABIX contains the index of the - existing or new - table entry with default key fields which match those of the entry to be processed.
    Notes
    COLLECT can create unique or compressed datasets and should be used precisely for this purpose. If uniqueness or compression are unimportant, or two values with identical default key field values could not possibly occur in your particular task, you should use APPEND instead. However, for a unique or compressed dataset which is also efficient, COLLECT is the statement to use.
    If you process a table with COLLECT , you should also use COLLECT to fill it. Only by doing this can you guarantee that
    the internal table will actually be unique or compressed, as described above and
    COLLECT will run very efficiently.
    If you use COLLECT with an explicitly specified work area, it must be compatible with the line type of the internal table.
    Example
    Compressed sales figures for each company
    DATA: BEGIN OF COMPANIES OCCURS 10,
            NAME(20),
            SALES TYPE I,
          END   OF COMPANIES.
    COMPANIES-NAME = 'Duck'.  COMPANIES-SALES = 10.
    COLLECT COMPANIES.
    COMPANIES-NAME = 'Tiger'. COMPANIES-SALES = 20.
    COLLECT COMPANIES.
    COMPANIES-NAME = 'Duck'.  COMPANIES-SALES = 30.
    COLLECT COMPANIES.
    The table COMPANIES now has the following appearance:
    NAME SALES
    Duck 40
    Tiger 20
    Addition
    ... SORTED BY f
    Effect
    COLLECT ... SORTED BY f is obsolete and should no longer be used. Use APPEND ... SORTED BY f which has the same meaning.
    Note
    Performance
    The cost of a COLLECT in terms of performance increases with the width of the default key needed in the search for table entries and the number of numeric fields with values which have to be added up, if an entry is found in the internal table to match the default key fields.
    If no such entry is found, the cost is reduced to that required to append a new entry to the end of the table.
    A COLLECT statement used on a table which is 100 bytes wide and has a key which is 60 bytes wide and seven numeric fields is about approx. 50 msn (standardized microseconds).
    Note
    Runtime errors
    COLLECT_OVERFLOW : Overflow in integer field when calculating totals.
    COLLECT_OVERFLOW_TYPE_P : Overflow in type P field when calculating totals.
    Thanks & regards
    Sreenivasulu P

  • Issue while using Collect statement in program

    Hi friend's,
    i have some issue regarding Collect statement..
    Issue is somthing like this,i have created a structure and internal table and work area with same type,
    u can look in below code..i wann to collect 'enmng' f'ield value whose matnr,charg,mvt type ,aufnr,rsnum are same but rspos and lgort are differnt for this i need to collect 'ENMNG' field value can any one tel me what to do...it not collectng value instead of this it append entire row...
    types: begin of ty_resb,
            rsnum   type resb-rsnum,                "Resrvation Number
            rspos   type resb-rspos,                "item position
            xloek   type resb-xloek,                "Item Deleted  if = 'X'
            matnr   type resb-matnr,                "Material Number
            lgort   type resb-lgort,                "Storage location  'REJT'
            charg   type resb-charg,                "Batch No
            enmng   type resb-enmng,                "Quantity withdrawn should be greater then '0'
            enwrt   type resb-enwrt,                "Value Withdrawn
            aufnr   type resb-aufnr,                "Order
            bwart   type resb-bwart,                "Movement type
       end of ty_resb.
    data:tt_resb  type table of  ty_resb ,
          tt_resb1 type table of ty_resb ,
          tt_resb2 type standard table of ty_resb ,
    **workarea.
          ts_resb type ty_resb,
          ts_resb2 type ty_resb,
          ts_resb1 type ty_resb.
    **move data to another internal table
    tt_resb1[] = tt_resb[].
    sort tt_resb  by rsnum rspos matnr charg bwart lgort aufnr .
    sort tt_resb1 by rsnum rspos matnr charg bwart lgort aufnr.
    DELETE adjacent duplicates from tt_resb  comparing rsnum rspos matnr charg bwart lgort aufnr .
    DELETE adjacent duplicates from tt_resb1 comparing rsnum rspos matnr charg bwart lgort aufnr.
    loop at tt_resb into ts_resb .
    clear:ts_resb1,ts_resb2.
    read table tt_resb1 into ts_resb1 with key rsnum = ts_resb-rsnum rspos = ts_resb-rspos matnr = ts_resb-matnr
                                                charg = ts_resb-charg aufnr = ts_resb-aufnr binary search.
    if ts_resb1-bwart = '261' .
        move ts_resb1-aufnr to ts_resb2-aufnr.
        move ts_resb1-matnr to ts_resb2-matnr.
        move ts_resb1-charg to ts_resb2-charg.
        move ts_resb1-bwart to ts_resb2-bwart.
        move ts_resb1-enwrt to ts_resb2-enwrt.
        move ts_resb1-lgort to ts_resb2-lgort.
        move ts_resb1-enmng to ts_resb2-enmng.
        collect ts_resb2 into tt_resb2.
    endif.
    clear ts_resb.
    endloop.
    Regard's,
    shaikh khalid.

    Hi Shaikh,
    I have added new declarations as highlighted below and new lines within your loop:
    Execute your program in debug mode and see what happens to the internal tt_collect I added. The collect will sum the fields enmng for all entries that  have same value on the fields matnr,charg,mvt type ,aufnr,rsnum.
    Question from me: what do you want to do with the collected/Summed up entries?
    types: begin of ty_resb,
            rsnum   type resb-rsnum,                "Resrvation Number
            rspos   type resb-rspos,                "item position
            xloek   type resb-xloek,                "Item Deleted  if = 'X'
            matnr   type resb-matnr,                "Material Number
            lgort   type resb-lgort,                "Storage location  'REJT'
            charg   type resb-charg,                "Batch No
            enmng   type resb-enmng,                "Quantity withdrawn should be greater then '0'
            enwrt   type resb-enwrt,                "Value Withdrawn
            aufnr   type resb-aufnr,                "Order
            bwart   type resb-bwart,                "Movement type
       end of ty_resb.
    data:tt_resb  type table of  ty_resb ,
          tt_resb1 type table of ty_resb ,
          tt_resb2 type standard table of ty_resb ,
    types: begin of ty_collect,
      rsnum   type resb-rsnum,
      matnr   type resb-matnr,
      charg   type resb-charg,
      bwart   type resb-bwart,
      aufnr   type resb-aufnr, 
      enmng   type resb-enmng,
           end of ty_collect.
    data: tt_collect type table of ty_collect,
          ts_collect type ty_collect.
    **workarea.
          ts_resb type ty_resb,
          ts_resb2 type ty_resb,
          ts_resb1 type ty_resb.
    **move data to another internal table
    tt_resb1[] = tt_resb[].
    sort tt_resb  by rsnum rspos matnr charg bwart lgort aufnr .
    sort tt_resb1 by rsnum rspos matnr charg bwart lgort aufnr.
    DELETE adjacent duplicates from tt_resb  comparing rsnum rspos matnr charg bwart lgort aufnr .
    DELETE adjacent duplicates from tt_resb1 comparing rsnum rspos matnr charg bwart lgort aufnr.
    loop at tt_resb into ts_resb .
    clear:ts_resb1,ts_resb2.
    read table tt_resb1 into ts_resb1 with key rsnum = ts_resb-rsnum rspos = ts_resb-rspos matnr = ts_resb-matnr
                                                charg = ts_resb-charg aufnr = ts_resb-aufnr binary search.
    if ts_resb1-bwart = '261' .
        move ts_resb1-aufnr to ts_resb2-aufnr.
        move ts_resb1-matnr to ts_resb2-matnr.
        move ts_resb1-charg to ts_resb2-charg.
        move ts_resb1-bwart to ts_resb2-bwart.
        move ts_resb1-enwrt to ts_resb2-enwrt.
        move ts_resb1-lgort to ts_resb2-lgort.
        move ts_resb1-enmng to ts_resb2-enmng.
        collect ts_resb2 into tt_resb2.
         move-corresponding ts_resb1 to ts_collect.
         collect ts_collect into tt_collect
    endif.
    clear ts_resb.
    clear ts_collect.
    endloop.

  • How to use collect statement properly

    In PBID table , i will get 4 rows for a material . I will get the corresponding values of bdzei from the same table . Now i will pass this bdzei into pbhi table. then i will get some 200 rows of data. I have to sum up the field plnmg , by grouping the laeda field of pbhi. In short, i need to know the sum of pbhi-plnmg for a particular pbhi-laeda . I know a way to do it. But i want to know how to use the COLLECT statement for this purpose. My output should contain oly 1 line for 1 material ..
    PBID table                      
    Matnr   BDZEI
    p4471   457
            1002
            2309
            2493
    PBHI table
    BDZEI     LAEDA         PLNMG
    1002     06.08.2004     0.000          
    1002     06.08.2004     83.000
    457      07.08.2004     12.000          
    457     07.08.2004     24.000
    Reqd O/p
    MATNR   LAEDA        PLNMG
    p4471  06.08.2004    83
    p4471  07.08.2004    36
    Hope u understood my situation .please help me out ...
    Thanking you in advance ..
    Shankar

    REPORT zppr_zpipr NO STANDARD PAGE HEADING LINE-SIZE 150 LINE-COUNT 63.
    TABLES: pbid,
            pbhi,
            makt,
            mseg,
            mkpf.
    DATA: BEGIN OF it_pbid OCCURS 0,
          matnr LIKE pbid-matnr,        " Material
          status TYPE c LENGTH 4,       " For distinguishing materials from pbid and pbim .. will contain space for PBID and 'PBIM' for PBIM
          bdzei LIKE pbid-bdzei,
          laeda LIKE pbhi-laeda,
    end of it_pbid.
    DATA: BEGIN OF it_pbim OCCURS 0,
          matnr LIKE pbid-matnr,        " Material
          status TYPE c LENGTH 4,       " For distinguishing materials from pbid and pbim .. will contain space for PBID and 'PBIM' for PBIM
          bdzei LIKE pbim-bdzei,
          laeda LIKE pbhi-laeda,
    end of it_pbim.
    DATA: BEGIN OF it_pbid_pbim OCCURS 0,
          matnr LIKE pbid-matnr,        " Material
          laeda LIKE pbhi-laeda,        " Reduction Date
          dbmng LIKE pbhi-dbmng,        " Planned quantity in the data base
          plnmg LIKE pbhi-plnmg,        " Planned quantity
          status TYPE c LENGTH 4,       " For distinguishing materials from pbid and pbim .. will contain space for PBID and 'PBIM' for PBIM
          mblnr LIKE mseg-mblnr,        " Material Doc Number
          pbfnr LIKE pbid-pbdnr,        " Plan Number
          maktx LIKE makt-maktx,         " Matl Desc
          aenam LIKE pbhi-aenam,        " User Changed
          erfmg LIKE mseg-erfmg,        " Qty Invoiced
          budat LIKE mkpf-budat,        " Invoice date
          bdzei LIKE pbid-bdzei,        " Independent requirements pointer
          werks LIKE pbid-werks,        " plant
          pirrednqty TYPE i,            " PIR Reduction Quantity        = pbih-plnmg - pbih-dbmng
          diff TYPE i,                  " Difference
          slno TYPE i,                  " Sl No
    END OF it_pbid_pbim.
    DATA: BEGIN OF it_allrows OCCURS 0.
            INCLUDE STRUCTURE it_pbid_pbim.
    DATA: END OF it_allrows.
    *DATA: BEGIN OF it_final OCCURS 0.
           INCLUDE STRUCTURE it_pbid_pbim.
    *DATA: END OF it_final.
    DATA: BEGIN OF line,
          matnr LIKE pbid-matnr,        " Material
          laeda LIKE pbhi-laeda,        " Reduction Date
          plnmg LIKE pbhi-plnmg,        " Planned quantity
          maktx LIKE makt-maktx,        " Matl Desc
          dbmng LIKE pbhi-dbmng,        " Planned quantity in the data base
          mblnr LIKE mseg-mblnr,        " Material Doc Number
          pbfnr LIKE pbid-pbdnr,        " Plan Number
          aenam LIKE pbhi-aenam,        " User Changed
          erfmg LIKE mseg-erfmg,        " Qty Invoiced
          budat LIKE mkpf-budat,        " Invoice date
          bdzei LIKE pbid-bdzei,        " Independent requirements pointer
          werks LIKE pbid-werks,        " plant
          pirrednqty TYPE i,            " PIR Reduction Quantity        = pbih-plnmg - pbih-dbmng
          diff TYPE i,                  " Difference
          slno TYPE i,                  " Sl No
          status TYPE c LENGTH 4,       " For distinguishing materials from pbid and pbim .. will contain space for PBID and 'PBIM' for PBIM
    END OF line.
    DATA Itfinal1 LIKE STANDARD TABLE
                OF LINE
              WITH DEFAULT KEY.
    DATA ITfinal LIKE ITfinal1.
    DATA: BEGIN OF it_dates OCCURS 0,
          date TYPE sy-datum,
    END OF it_dates.
    DATA: l_slno TYPE i.
    DATA: l_zebra TYPE c.
    SELECT-OPTIONS:
          s_werks FOR pbid-werks obligatory.
    SELECT-OPTIONS:
          s_matnr FOR pbid-matnr.
    SELECT-OPTIONS:
          s_pbdnr FOR pbid-pbdnr.
    SELECT-OPTIONS:
          s_laeda FOR pbhi-laeda obligatory.
    parameter:
          c_print type checkbox.
    SELECT matnr bdzei FROM pbid INTO (it_pbid-matnr, it_pbid-bdzei) WHERE werks IN s_werks AND matnr IN s_matnr AND pbdnr IN s_pbdnr.
      it_pbid-status = 'PBID'.
      APPEND it_pbid.
    move-corresponding it_pbid to it_pbid_pbim.
    Append it_pbid_pbim.
    ENDSELECT.
    SELECT matnr bdzei FROM pbim INTO  (it_pbim-matnr,it_pbim-bdzei) WHERE werks IN s_werks AND matnr IN s_matnr AND pbdnr IN s_pbdnr.
      APPEND it_pbim.
    Append it_pbid_pbim.
    ENDSELECT.
    *break-point.
    START-OF-SELECTION.
      LOOP AT s_laeda.
        it_dates-date = s_laeda-low.
        APPEND it_dates.
      ENDLOOP.
      DATA: l_startdate LIKE sy-datum.
      IF s_laeda-high EQ space.
      ELSE.
        l_startdate = s_laeda-low + 1.
        DO.
          IF l_startdate <= s_laeda-high.
            it_dates-date = l_startdate.
            APPEND it_dates.
          ELSE.
            it_dates-date = sy-datum.
            EXIT.
          ENDIF.
          l_startdate = l_startdate + 1.
        ENDDO.
      ENDIF.
    *break-point.
      LOOP AT it_pbim.
        LOOP AT it_dates.
          it_pbim-laeda = it_dates-date.
          it_pbim-status = 'PBIM'.
          MODIFY it_pbim TRANSPORTING laeda status.
          MOVE-CORRESPONDING it_pbim TO it_pbid_pbim.
          APPEND it_pbid_pbim.
        ENDLOOP.
      ENDLOOP.
    break-point.
      l_zebra = 'X'.
      DATA: l_toterfmg LIKE mseg-erfmg.
      DATA: l_erfmg LIKE mseg-erfmg.
      data: l_totpir type i.
    **************************************PBID*************************************
      LOOP AT it_pbid.
        move-corresponding it_pbid to it_pbid_pbim.
           append it_pbid_pbim.
        SELECT SINGLE maktx FROM makt INTO (it_pbid_pbim-maktx) WHERE matnr = it_pbid-matnr.
        MODIFY table it_pbid_pbim TRANSPORTING maktx.
        SELECT aenam laeda FROM pbhi INTO (it_pbid_pbim-aenam,it_pbid_pbim-laeda) WHERE bdzei = it_pbid-bdzei AND aenam = 'Abbau-'.
           MODIFY TABLE it_pbid_pbim TRANSPORTING aenam laeda. " debug here
        select single sum( dbmng )  sum( plnmg ) FROM pbhi INTO (it_pbid_pbim-dbmng,it_pbid_pbim-plnmg) WHERE bdzei = it_pbid-bdzei AND aenam = 'Abbau-' and laeda = it_pbid_pbim-laeda..
           MODIFY TABLE it_pbid_pbim TRANSPORTING dbmng plnmg. " debug here
       endselect.
        it_pbid_pbim-pirrednqty = it_pbid_pbim-dbmng - it_pbid_pbim-plnmg.
           MODIFY table it_pbid_pbim TRANSPORTING pirrednqty.
        IF ( it_pbid_pbim-laeda IN s_laeda AND it_pbid_pbim-aenam EQ 'Abbau-' ).
          MOVE-CORRESPONDING it_pbid_pbim TO it_allrows.
          append it_allrows.
        ELSEIF NOT it_pbid_pbim-laeda IN s_laeda.
              delete it_pbid_pbim index sy-tabix.           " debug here
        ENDIF.
        ENDSELECT.
      ENDLOOP.
    **************************************PBIM*************************************
      LOOP AT it_pbim.
        move-corresponding it_pbim to it_pbid_pbim.
           append it_pbid_pbim.
        SELECT SINGLE maktx FROM makt INTO (it_pbid_pbim-maktx) WHERE matnr = it_pbim-matnr.
           MODIFY table it_pbid_pbim TRANSPORTING maktx.
        SELECT aenam laeda FROM pbhi INTO (it_pbid_pbim-aenam,it_pbid_pbim-laeda) WHERE bdzei = it_pbim-bdzei AND aenam = 'Abbau-'.
           MODIFY TABLE it_pbid_pbim TRANSPORTING aenam laeda. " debug here
        select single sum( dbmng )  sum( plnmg ) FROM pbhi INTO (it_pbid_pbim-dbmng,it_pbid_pbim-plnmg) WHERE bdzei = it_pbim-bdzei AND aenam = 'Abbau-' and laeda = it_pbid_pbim-laeda..
           MODIFY TABLE it_pbid_pbim TRANSPORTING dbmng plnmg. " debug here
        it_pbid_pbim-pirrednqty = it_pbid_pbim-dbmng - it_pbid_pbim-plnmg.
           MODIFY table it_pbid_pbim TRANSPORTING pirrednqty.
        IF ( it_pbid_pbim-laeda IN s_laeda AND it_pbid_pbim-aenam EQ 'Abbau-' ).
          MOVE-CORRESPONDING it_pbid_pbim TO it_allrows.
          append it_allrows.
        ELSEIF NOT it_pbid_pbim-laeda IN s_laeda.
              delete it_pbid_pbim index sy-tabix.           " debug here
        ENDIF.
        ENDSELECT.
      ENDLOOP.
    sort it_allrows by matnr laeda status.
    **********************************ALL ROWS************************
    loop at it_allrows.
      line-matnr = it_allrows-matnr.
      line-laeda = it_allrows-laeda.
      line-plnmg = it_allrows-plnmg.
      line-dbmng = it_allrows-dbmng.
    line-mblnr = it_allrows-mblnr.
    line-pbfnr = it_allrows-pbfnr.
      line-maktx = it_allrows-maktx.
    line-aenam = it_allrows-aenam.
    line-erfmg = it_allrows-erfmg.
    line-budat = it_allrows-budat.
      line-bdzei = it_allrows-bdzei.
    line-werks = it_allrows-werks.
      line-pirrednqty = it_allrows-pirrednqty.
      line-diff = it_allrows-diff.
      line-slno = it_allrows-slno.
      line-status = it_allrows-status.
      collect line into itfinal1.
    endloop.
    loop at itfinal1 into line.
      collect line into itfinal.
        write: / line-matnr, line-plnmg, line-dbmng,line-laeda,line-status..
    endloop.
    skip 4.
    loop at itfinal into line.
      write: / line-matnr, line-plnmg, line-dbmng,line-laeda,line-status..
    endloop.
    break-point.

  • Problem in collect statement

    Hi,
    i have requirement to get all unique entries from table .if i am getting duplicate record then i need to add qunatity field which i have define like rlbes-anfme.
    my internal table is :
    11 name1 23.00
    22 name2 1,324.00
    11 name1 10.00
    I want output in this way
    11 name1  33.00
    22 name2 1,324.00
    i tried to use collect statement but the problem is its not working on character type field.
    if  i use packed field then i am not able to upload my file because i am getting quantity filed 1,2344.00 this way.( instead of 1325.00)
    please give me any solution.
    thanks,
    jack

    Hi,
    Try this..
    Create another internal table which has the same structure of your internal table.
    DATA: LT_COLLECT LIKE ITAB OCCURS 0 WITH HEADER LINE.
    DATA: V_QUANTITY TYPE MENGE_D.
    Sort the internal table.
    SORT ITAB BY field1 field2.    " Give the appropriate field names.
    <b>* process the internal table which has the records.</b>
    LOOP AT ITAB.
    Sum up the quantity.
       V_MENGE = V_MENGE + ITAB-ANFME.  " Quantity field.
    Move the first two fields.
       LT_COLLECT-FIELD1 = ITAB-FIELD1. 
       LT_COLLECT-FIELD2 = ITAB-FIELD2.
    At the end of the record..append the record.
       AT END OF FIELD2.     " Give the corresponding field name.
          LT_COLLECT-ANFME = V_MENGE.
          APPEND LT_COLLECT.
         CLEAR: V_MENGE.
       ENDAT.  
    ENDLOOP.
    Thanks,
    Naren

  • Report in which collect statement .

    report in which collect statement  is used and also its purpose.

    COLLECT
    Basic form
    COLLECT [wa INTO] itab.
    Addition
    ... SORTED BY f
    Effect
    COLLECT is used to create unique or compressed datsets. The key fields are the default key fields of the internal table itab .
    If you use only COLLECT to fill an internal table, COLLECT makes sure that the internal table does not contain two entries with the same default key fields.
    If, besides its default key fields, the internal table contains number fields (see also ABAP/4 number types ), the contents of these number fields are added together if the internal table already contains an entry with the same key fields.
    If the default key of an internal table processed with COLLECT is blank, all the values are added up in the first table line.
    If you specify wa INTO , the entry to be processed is taken from the explicitly specified work area wa . If not, it comes from the header line of the internal table itab .
    After COLLECT , the system field SY-TABIX contains the index of the - existing or new - table entry with default key fields which match those of the entry to be processed.
    Notes
    COLLECT can create unique or compressed datasets and should be used precisely for this purpose. If uniqueness or compression are unimportant, or two values with identical default key field values could not possibly occur in your particular task, you should use APPEND instead. However, for a unique or compressed dataset which is also efficient, COLLECT is the statement to use.
    If you process a table with COLLECT , you should also use COLLECT to fill it. Only by doing this can you guarantee that
    the internal table will actually be unique or compressed, as described above and
    COLLECT will run very efficiently.
    If you use COLLECT with an explicitly specified work area, it must be compatible with the line type of the internal table.
    Example
    Compressed sales figures for each company
    DATA: BEGIN OF COMPANIES OCCURS 10,
    NAME(20),
    SALES TYPE I,
    END OF COMPANIES.
    COMPANIES-NAME = 'Duck'. COMPANIES-SALES = 10.
    COLLECT COMPANIES.
    COMPANIES-NAME = 'Tiger'. COMPANIES-SALES = 20.
    COLLECT COMPANIES.
    COMPANIES-NAME = 'Duck'. COMPANIES-SALES = 30.
    COLLECT COMPANIES.
    The table COMPANIES now has the following appearance:
    NAME SALES
    Duck 40
    Tiger 20
    Addition
    ... SORTED BY f
    Effect
    COLLECT ... SORTED BY f is obsolete and should no longer be used. Use APPEND ... SORTED BY f which has the same meaning.
    Note
    Performance
    The cost of a COLLECT in terms of performance increases with the width of the default key needed in the search for table entries and the number of numeric fields with values which have to be added up, if an entry is found in the internal table to match the default key fields.
    If no such entry is found, the cost is reduced to that required to append a new entry to the end of the table.
    A COLLECT statement used on a table which is 100 bytes wide and has a key which is 60 bytes wide and seven numeric fields is about approx. 50 msn (standardized microseconds).
    Note
    Runtime errors
    COLLECT_OVERFLOW : Overflow in integer field when calculating totals.
    COLLECT_OVERFLOW_TYPE_P : Overflow in type P field when calculating totals.

  • Advice regarding how best to collect stats on 10G RAC Production system

    Friends,
    I have read quite a lot of blogs and docs and need some help with the best way forward. I am a DBA new to RAC who has limited experience with busy 24@7 10g systems on the scale of my current employer.
    Historically stats are gathered here as follows :-
    exec dbms_stats.unlock_schema_stats('BP');
    exec dbms_stats.gather_schema_stats(ownname => 'BP', cascade => true, estimate_percent => dbms_stats.auto_sample_size);
    exec dbms_stats.lock_schema_stats('BP');
    Then Flush shared pool ok ????
    Because of previous issues with this - alll tables are currently locked and this process is recommended for every 1-2 months rather than daily.
    EM Grid Control is used when performance is poor and the sql tuning advisor is run to generate recommendations from which a sql profile could be selected and enabled for the selected code.
    My plan is to bring back gathering of stats every 1 to 2 months, my goal is make sure I can fix things quickly if it all goes to custard !!!!
    From research it looks like sql_profile is like a hint and independent of gathering stats - it tells optimiser what hints to use when executing sql.
    This thread is for advice from professional dba's in my shoes - how do you approach this so that any issues are quickly rectified ???
    My thinking is to query dba_profiles and get list of profiles and statuses ... for all tables with sql profiles ..
    This is so profiles can be disabled and then quickly enabled if there is a problem aftewr the tables are analyzed.
    To revert all the schema stats :-
    exec dbms_stats.unlock_schema_stats('BP');
    exec dbms_stats.restore_schema_stats(ownname=>'BP',as_of_timestamp=>sysdate-1);
    exec dbms_stats.lock_schema_stats('BP');
    To revert a table's stats (this looks more finicky so not sure the way to go ...):-
    Pre gather stats :-
    select stats_update_time from user_tab_stats_history where table_name = ‘<EnterTabName>’;
    exec dbms_stats.create_stat_table ( -‘SCOTT’, -‘stattab_new’);
    exec dbms_stats.export_table_stats ( -‘SCOTT’, -‘DEPT’, -null, -‘stattab_new’, -null, -true, -‘SCOTT’);
    Then later after gather stats :-
    exec dbms_stats.restore_table_stats ( -‘SCOTT’, -‘DEPT’, -’21-JAN-09 11.00.00.000000 AM -05:00′);
    Enable/Disable Profile
    exec dbms_sqltune.alter_sql_profile('<Profile name>', 'STATUS', 'DISABLED');
    exec dbms_sqltune.alter_sql_profile('<Profile name>', 'STATUS', 'ENABLED');
    I will do the plan below on a test system first however load may not really identify problems until for real on the Prod system.
    My plan is to :-
    1 analyze all tables as per outline at start above (existing practice)
    2 Disable the sql profiles that are in use on the analyzed tables
    3 See what code is affected and what tables
    If Profile exists for these sql statements then either apply existing profile (as disabled) or use tuning adviser to create another profile
    (Advice welcome here - what do you do on big systems ????)
    4 If its a catastrophe - I can restore the schema stats using (exec dbms_stats.restore_schema_stats(ownname=>'BP',as_of_timestamp=>sysdate-1);)
    and then possibly re-enabling the sql_profiles that were in place before ....
    I welcome any advice based on similar experiences that can help me get this right.
    Many thanks,
    cheers, Rob
    Edited by: Diesel on Jun 27, 2012 10:51 PM

    Useful Link:
    http://www.oradev.com/create_statistics.jsp
    ## Gather schema stats
    begin
    dbms_stats.gather_schema_stats(ownname=>'SYSLOG');
    end;
    ## Gather a particular table stats of a schema
    begin
    DBMS_STATS.gather_table_stats(ownname=>'syslog',tabname=>'logs');
    end;
    Regards
    Asif Kabir
    --mark the answer as correct/helpful                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               

  • Doubt on Select Statement

    HI Friends,
    i have a requirement to select matnr,werks and mmsta from marc table.where i have input of matnr and mmsta.
    The matnr in the marc table having 2 werks with different mmsta.
    i was asked to select matnr not having mmsta 40.
    but in marc table there is same matnr with two mmsta 37 and 40.
    i want a select statement which should not pick matnr having 40.
    my select statement was
    select matnr werks mmsta into itab from marc
    where matnr in fpso_matnr and mmsta in fpso_mmsta.
    this does not work for the above condition.
    please suggest me a correct statement..
    Thanks,
    Gokul

    select matnr werks mmsta into itab from marc
    where matnr in fpso_matnr and mmsta in fpso_mmsta
       and mmsta NE 40.
    ill this not work ?
    MARC is plant data.. so I guess u need to give werks also...
    Edited by: jackandjay on Dec 19, 2007 12:02 PM

  • Collect statement not working

    Hi,
               My collect statement is not working. Kindly let me know what is the other way to add one filed in the loop.
    thanks
    Moderator message - Please ask a specific question - post locked
    Edited by: Rob Burbank on Nov 19, 2009 9:24 AM

    Same thing i faced few days ago --. i have resolved this using following logic ... try this it will workout
    CLEAR: wa_mkpf_mseg, w_werks, w_matnr, w_lgort, w_bwart.
    LOOP AT t_mkpf_mseg INTO wa_mkpf_mseg.
    IF wa_mkpf_mseg-werks EQ w_werks AND wa_mkpf_mseg-matnr EQ w_matnr AND wa_mkpf_mseg-lgort EQ w_lgort AND wa_mkpf_mseg-bwart EQ w_bwart.
    CLEAR: wa_p_coi.
    READ TABLE t_p_coi INTO wa_p_coi WITH KEY werks = wa_mkpf_mseg-werks matnr = wa_mkpf_mseg-matnr lgort = wa_mkpf_mseg-lgort bwart = wa_mkpf_mseg-bwart.
    IF sy-subrc = 0.
    wa_p_coi-Avg Days = wa_p_coi-Avg Days + wa_mkpf_mseg-Avg Days.
    MODIFY t_p_coi FROM wa_p_coi TRANSPORTING Avg Days .
    CLEAR: wa_p_coi, wa_p_coi.
    endif.
    ELSE.
    wa_p_coi-werks = wa_mkpf_mseg-werks.
    wa_p_coi-matnr = wa_mkpf_mseg-matnr.
    wa_p_coi-bwart = wa_mkpf_mseg-bwart.
    wa_p_coi-lgort = wa_mkpf_mseg-lgort.
    wa_p_coi-Avg Days = wa_mkpf_mseg-Avg Days .
    APPEND wa_p_coi TO t_p_coi.
    CLEAR: wa_p_coi.
    ENDIF.
    w_werks = wa_mkpf_mseg-werks.
    w_matnr = wa_mkpf_mseg-matnr.
    w_lgort = wa_mkpf_mseg-lgort.
    w_bwart = wa_mkpf_mseg-bwart.
    CLEAR: wa_mkpf_mseg.
    ENDLOOP.

  • Collect statement in a class.

    Hello,
    This is related to BW infospoke enhancement,
    in this class i have structure which is filled and i have to aggregate the data in this structure by one of the field level,
    i want to declare a internal table with header and take the data from structure into internal table and then do a collect statement on to this internal table..
    but i am getting a message that no one more header line is supported in OOPS concept..meaning i am not able to declare a internal table with header line..
    any solution to this will be awarded with points.

    Hello Shashi
    You should not use itab with header lines since they mess up any coding and are a nightmare when it comes to maintaining code.
    Fortunately, SAP has abandoned header lines from ABAP-OO. If you are not using table types then you have to define your own types, e.g.:
    TYPES: BEGIN OF ty_s_line.
    TYPES:   field_a  TYPE ... .
    TYPES:   field_b  TYPE ... .
    TYPES: END OF ty_s_line.
    TYPES: ty_t_itab  TYPE STANDARD TABLE OF ty_s_line
                      WITH DEFAULT KEY.
    DATA:
      ls_line   TYPE ty_s_line,
      lt_itab   TYPE ty_t_itab.
    * Now fill your itab, e.g.
      SELECT * FROM ... INTO CORRESPONDING FIELDS
                        OF TABLE lt_itab.
    * Now working with the itab data.
      LOOP AT lt_itab INTO ls_line.
      ENDLOOP.
    Regards
       Uwe

Maybe you are looking for

  • ArrayList help

    ok still having trouble, i redid alot of the program, i need to slim down the ArrayList to being one instance of a word per file, plus all of the lines they are on inside that one instance. Right now there are mulitple instances of each word and each

  • Copying and Pasting file paths in iChat

    Hi all, Since upgrading some of our machines at the office to Snow Leopard 10.6.4 and iChat 5.0.3 we are having a strange issue that I hope someone has some insight into. When all of the machines at our office ran Leopard and iChat 4, we used to send

  • Data Execution Prevention crashes Itunes in Vista

    I have tried to follow the directions in other threads or in the Apple help guide to this subject and the solutions do not work, or files they say should exist do not exist. P Please help me with a fresh or guided approach. This issue just started wi

  • When I print a pdf file, the first page is dramatically  reduced in size while remainder pages print correct size. How do I fix this pro blem?

    recently, when printing pdf files, the first page prints out as 1/10 or 1/20th original size while rest of document prints correctly. I have no idea how this happened or why and I have no idea how to fix. I cannot get the first page of any pdf doocum

  • How to install Oracle Pro*C/C++ ?

    We installed oracle cluster and database for a RAC system. They are at version 10.2.0.4 (installed 10.2.0.1 and apply patchset to 10.2.0.4). Now our development team want to have Pro*C/C++ installed on the same server. Where I can find the product (d