I have a labview 7 vi and i have labview 6.1

I have a labview 7 vi that get data from excel specified field. I have only labview 6.1 : could someone translate or "save as" these vi in labview 6.1 format ?
Thanks in advance.
Attachments:
Excel_Get_Data_Specified_Field.vi ‏124 KB
Row_Col_To_Range_Format.vi ‏43 KB

vi's converted to version 6.1
Attachments:
Row_Col_To_Range_Format.vi ‏35 KB
Excel_Get_Data_Specified_Field.vi ‏102 KB

Similar Messages

  • I have LabView but I do not have the Calibration and Configuration Palette,and I could not download it, how can I download it or if i cannot,can I work with the NI-DAQ Calibration_1200?

    I have read in a tutorial for the board 1200 that I can calibrate it with the Calibration and Configuration Palette in LabVIEW, but I do not have them and I could not download it to access its libraries, so I can only download the NI-DAQ software,What's my best choice and if it is to download the palette with its libraries, how can download it with them?I'd appreciate your answers

    If you wish to use your 1200 device in LabVIEW, you must download and install NI-DAQ. When you install NI-DAQ, it will ask you if you would like to install support for LabVIEW. By installing this support, you will then have access to the DAQ pallette in LabVIEW. The DAQ pallette requires that you have NI-DAQ installed.
    For more information on installing and using your device, you can refer to the DAQ Quick Start Guide. You can download it from:
    http://digital.ni.com/manuals.nsf/14807683e3b2dd8f8625677b006643f0/0eca53fe80911b1f862568560068295d
    Regards,
    Erin

  • I am receiving the data through the rs232 in labview and i have to store the data in to the word file only if there is a change in the data and we have to scan the data continuasly how can i do that.

    i am receiving the data through the rs232 in labview and i have to store the data in to the word or text file only if there is a change in the data. I have to scan the data continuasly. how can i do that. I was able to store the data into the text or word file but could not be able to do it.  I am gettting the data from rs232 interms of 0 or 1.  and i have to print it only if thereis a change in data from 0 to 1. if i use if-loop , each as much time there is 0 or 1 is there that much time the data gets printed. i dont know how to do this program please help me if anybody knows the answer

    I have attatched the vi.  Here in this it receives the data from rs232 as string and converted into binery. and indicated in led also normally if the data 1 comes then the led's will be off.  suppose if 0 comes the corresponding data status is wrtten into the text file.  But here the problem is the same data will be printed many number of times.  so i have to make it like if there is a transition from 1 to o then only print it once.  how to do it.  I am doing this from few weeks please reply if you know the answer immediatly
    thanking you 
    Attachments:
    MOTORTESTJIG.vi ‏729 KB

  • I have a problem with simulation in Matlab 6.5 and LabVIEW for PID controllers

    I have a problem with simulation in Matlab 6.5 and LabVIEW. I have some methods for granting PID controllers in MATLAB to go but not LabVIEW. International Teams degree to transfer two but when I go past the fourth degree no longer work. We changed the formula for calculating the parameters for grade four and gave me some good values for Matlab award but when I put on LabVIEW have not settled. formulas are available in PDF and are. Please help me and me someone if possible. Thanks
    lim.4 generation parameters in MATLAB program and comparison methods are for second-degree transfer function.
    Solved!
    Go to Solution.
    Attachments:
    Pt net.zip ‏2183 KB

    This is the VIs what i try to make,but is not work. This pdf. document was used to create last VIs PID. thenk you for your colaboration.
    Attachments:
    PID create by me.vi ‏312 KB
    tut_3782.pdf ‏75 KB

  • I installed LabVIEW 5.1 on an XP machine and some of the VI's, such as fit to curve, do not have icons. Instead, they have a ? where the icon should be, and they cannot be inserted into my VI's. Can anyone fix this?

    I am using a Dell Inspiron I8100 Laptop with Windows XP Home and am running LabVIEW 5.1 in Windows 95 compatability [I also did so for the install to get rid of the "wrong os" message]. I am able to use nearly all of the functions, but a few of them did not make the transition to my machine. I cannot use some of the VI's contained in the Mathematics sub-palette, I cannot use some of the demos, and it is really setting me back. Instead of an icon for the Mathematics>>Curve Fit sub-palette I get a ? in an icon-sized box that says Curve Fit for it
    s description. Can anyone fix these broken links?
    Attachments:
    LabView.bmp ‏2731 KB
    labview2.bmp ‏2731 KB

    From your discussion I have seen that you try to use LV 5.1.
    It seems that 5.1.1 will work correct. The difference is that 5.1.1 is compatible with Win 2000 and 5.1 is not. This can by a issue.
    Another thing I have seen under Win2000 is the rights a user has. Since you use XP Home there should be no restrictions to the user of the machine. One thing to take into account is do you install and use LV as the same user?
    Waldemar
    Waldemar
    Using 7.1.1, 8.5.1, 8.6.1, 2009 on XP and RT
    Don't forget to give Kudos to good answers and/or questions

  • How can I handle deploying multiple test systems on the same PC that have been developed using different versions of LabVIEW, TestStand, and/or Switch Executive?

    The major issue here is that the test systems must be documented and validated before being released to the production floor. Given this if a test station has multiple test systems deployed on it that have been developed on various versions of LV, TS, and Switch exec how can I force the test system selected to use the correct versions of TS, LV, and Switch exec.? I understand that the solution would be to recomplie everything and bring them up to the latest version but that would then require re-validation according to the QA department. Any advice would be greatly appreciated.
    It would be nice if theTS deployment was more like an LV executable... meaning when a LV executable is launched it always knows what LV runtime engine to use when there are multiple engines installed on a PC.

    Hi,
    Multiply versions of teststand can reside on the same system, but only one version can run at a time. They is a utility that has to be run to set the active version.
    The SequenceFiles have a version number, and you will find an error will be generate if you try to Load the sequencefile in the wrong version of TestStand.
    The labview VIs will only work providing the correct version of the RTE is also installed on your system, even a labview executabe requires the correct RTE to be installed, either as part of the executable installation or as a seperate installation, before the labview exe will work correctly.
    I'm not fimilar with the Switch exec but I would expect that it will also require the correct lower level device drivers to be available for the version you are using.
    Therefore, as you are indicating that some of your system are at  a older version, its difficult to image how you could achive this, considering if you say you have different versions of the software(s). For a start, you may have the problem that newer code/ sequencefiles using additional functionatily not available in the older versions.
    I would think your only solution would  be to have different deployments covering the different versions you have, or at least bring all your test systems up to the same version of teststand.
    Regards
    Ray Farmer
    Regards
    Ray Farmer

  • I have a application build in labview 8.5 for Windows XP using NI Visa functions to interact with hardware , how to make is work in Windows 7 32 bit and Win 7 64 bit

    I have a application build in Labview 8.5 which wroks fine with Windows XP , this program uses basic read /write functions of NI Visa to communicate with Hardware . This application doesnt work with Windows 7 32 bit/64 and Vista . What changes i need to do to make it work for the said operating system

    srinivas wrote:
    Sorry for confusion ,
    My question is what changes i need to do in code or while making the installer to make the existing program work with other Windows operating system
    You need to make sure the machine have the corresponding NI-VISA installed. Check in the NI software pages for the right version.
    Also make sure that the com port's can be selected when you first start the application. Eg. if you refer to VISA "COM1" on the XP machine It might be "COM2" on the Win7 machine.
    Br,
    /Roger

  • I can not create an Installer, After install the Vision Builder Demo and then uninstall it. I can not create a Labview installer anymore, it asks me for a Vision Builder Installer, even if My Labview program does not have nothing to do with it...

    I can not create an Installer on LabView, After install the Vision Builder Demo and then uninstall it. I can not create a Labview installer anymore, it asks me for a Vision Builder Installer, even if My Labview program does not have nothing to do with it...
    Solved!
    Go to Solution.

     Hi Shada this can happen if you are including additional installers to your installer for example DAQmx. When you are doing this the installer has to include other files like MAX (Measuremente and Automation Explorer). Probably when you installed Vision Builder it updated MAX, so when your installer is trying to Include MAX, its asking for the source where it was installed in your computer in this case Vision Builder.
     Here you can cache the information so its not asked again, or you can download a newer version fo DAQmx, so it will update MAX and change de dependecy.
     You can find more details about this issue in this KB:
    KnowledgeBase 3S88PJMY: Why Do I Get A "Missing Distribution" Error When Trying to Build an Installe...
    And for keeping a copy here is more info:
     How Do I Stop the Missing Distribution Notification Each Time I Build An Installer?
    Best Regards
    Benjamin C
    Senior Systems Engineer // CLA // CLED // CTD

  • How to start with FPGA and LABVIEW when you do not know any computer language? Only have exposure to Windows OS.

    Myself is an Electronics Engineer. But I don't have any exposure to any comp language like C or whatever. I do not have any exposure to Labview as well. I've been involved in design and developing Digital Circuits like interlock units, Position monitoring and display systems etc. Now I want to work upon FPGA based circuits. Can anyone suggest me plz that how to start with?  

    Hi BNarendra;
    Here are some resources that can be useful, the first is an introduction to LabVIEW and the other ones are for LabVIEW FPGA.
    LabVIEW
    http://zone.ni.com/devzone/cda/tut/p/id/5247
    LabVIEW FPGA
    http://www.ni.com/swf/presentation/us/labview/lvfpga/default.htm
    http://digital.ni.com/public.nsf/allkb/0697A6F4BFC6E152862570FA0072153A?OpenDocument
    http://zone.ni.com/devzone/cda/tut/p/id/3261
    I hope the information is useful.
    Good Luck!
    Francisco Arellano
    National Instruments Mexico
    Field Systems Engineer - Energy Segment
    www.ni.com/soporte

  • I have to send messages through UDP multicast and unicast from same port. In Labview I tried that it throws error. I heard it is possible by means of Datagram (UDP unicast and multicast) Port Sharing. How can it be achieved in Labview?

    I have to send UDP multicast and Unicast messages to a remote port from a single source/local port. I tried by opening UDP unicast and multicast in the same port and got the expected error. I tried by opening a unicast connection and sending unicast messages.After that when multicast messages has to send I closed unicast and opened multicast in the same port.This is not throwing any error. But my requirenment is to comminicate with another application in C ++ which recieves this data, throwing an error of lost connectivity and both the applications are not abled to communicate properly. 
    In the other application with C++ this is implemented using port sharing. So how port sharing can be implemented in labview so that I can send both multicast and unicast messages from the same port?
    Thanks in advance

    UDP is a sessionless protocol, meaning that anyone listening on the specified port CAN receive the data. CAN because as you noted there is no guarantee in the protocol that it will be received. And if you send the data not to a specific address but a multicast address not only one computer can receive it but in fact every computer on the same subnet listening to that multicast address and depending on the TTL of the packet also computers in neighbouring subnets, although that last one is not a very reliable operation since routers can be configured to drop multicast packages anyhow despite of a different TTL saying otherwise.
    Accordingly there is no real way to make sure that a receiving UDP port is not already in use, since you don't build up a connection. UDP is more or less analogous to shouting your messages through a megaphone, and anyone listening on the right frequency (port) can hear it. You do bind the sender socket to a specific port number but that makes little difference.
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • I have written a binary file with a specific header format in LABVIEW 8.6 and tried to Read the same Data File, Using LABVIEW 7.1.Here i Found some difficulty.Is there any way to Read the Data File(of LABVIEW 8.6), Using LABVIEW 7.1?

    I have written a binary file with a specific header format in LABVIEW 8.6 and tried  to Read the same Data File, Using LABVIEW 7.1.Here i Found some difficulty.Is there any way to Read the Data File(of LABVIEW 8.6), Using LABVIEW 7.1?

    I can think of two possible stumbling blocks:
    What are your 8.6 options for "byte order" and "prepend array or string size"?
    Overall, many file IO functions have changed with LabVIEW 8.0, so there might not be an exact 1:1 code conversion. You might need to make some modifications. For example, in 7.1, you should use "write file", the "binary file VIs" are special purpose (I16 or SGL). What is your data type?
    LabVIEW Champion . Do more with less code and in less time .

  • I have got a 1500 Kinetic Systems CAMAC crate and 3922 controller. I want to use it with LabView inst

    alled in PCI-bus IBM PC, which does not have GPIB interface. Which way would be easier for developing my own instrument driver: a new GPIB controller + interface or 2915 Kinetic Sys. PCI-bus in-slot interface? Can the latter interface be used with LabView?
    Many thanks.
    Victor. I have got a 1500 Kinetic Systems CAMAC crate and 3932 controller. I want to use it with LabView installed in PCI-bus IBM PC, which does not have GPIB interface. Which way would be easier for developing my own instrument driver: a new GPIB controller + interface or 2915 Kinetic Sys. PCI-bus in-slot interface? Thanks

    alled in PCI-bus IBM PC, which does not have GPIB interface. Which way would be easier for developing my own instrument driver: a new GPIB controller + interface or 2915 Kinetic Sys. PCI-bus in-slot interface? Can the latter interface be used with LabView?Victor,
    I couldn't find an Instrument Driver for the 3932 crate controler. There is a driver for the 3988: http://zone.ni.com/idnet97.nsf/9b2b33e1993d877786256436006ec498/045f8392cc4d1b01862568ab005fbb49?OpenDocument
    If you look at the driver it isn't too complex. Well ... actaully there are certain differences when using the 3988 GPIB controller that the driver takes care of that relate to correctly passing commands (FAN).
    If the 3922 controller is similar then maybe you can use the 3988 driver and modify it to meet your needs. I'm not familar with the 2915 Kinetic system so I'm not sure what would be easier.
    If you have a GPIB board, then you could try using the 3988 driver with your 3922 controller and see if you can modify the driver to get things to work.
    I
    've only used the 3988 and that was quite three years ago but it might be worth a try.
    Best of luck,
    Kamran - NI

  • I have some question on "Use LabVIEW to Control two DSP and RTDX"

    I have some question when writing LabVIEW. I have DSP6711 and DSP6416, I use RTDX to send data to LabVIEW.
    I write three programes for LabVIEW, one is RTDX for DSP6711, another is RTDX for DSP6416, and the final is RTDX for two DSPs.
    The program of LabVIEW is workable when doing DSP6711 or doing DSP6416. But there is some problem when running DSP6711 and DSP6416 on LabVIEW at the same time.
    How to tell the LabVIEW's tool of " RTDX read" to  get the datas from different DSP

    What you want to do should be fairly straightward and a good way to learn labview. 
    First off, if you haven't already, I would download the drivers for the Keithley and Agilent instruments.  I found the keithley drivers at the link below.  You will need to find the labview drivers for the Agilent PS at their website.  Drivers are the VI's you will use in your program to control the insturments.
    http://sine.ni.com/apps/we/niid_web_display.download_page?p_id_guid=E3B19B3E90B0659CE034080020E74861
    If you open Labview and go to the help menu and click on Labview bookshelf there is alot of information on getting you started coding labview.   This should get you started, if you have anymore questions just ask in this same thread and I am sure you will get all the help you need.
    Brian
    Message Edited by BrianPack on 09-14-2005 05:21 PM
    Message Edited by BrianPack on 09-14-2005 05:21 PM

  • I have Labview for HP-UX and a HPIB card. Is there a way to make them work?

    I appreciate any pointers.
    Jose Chacon
    Florida

    Jose,
    There is a KnowledgeBase entry that talks about using NI-VISA 2.5 to communicate with an HPIB board through LabVIEW 6. Unfortunately, this is only possible in Windows. For HP-UX I'm afraid your only option is to use a Call Library Node in your LabVIEW program to make direct calls to the HPIB driver. If you can obtain documentation on the HPIB shared libraries that come with the board, it is viable for you to communicate directly through a Call Library Node.
    I hope this suggestion points you in the right direction. Have a good day.
    Sincerely,
    Darren Nattinger
    Applications Engineer
    National Instruments
    Darren Nattinger, CLA
    LabVIEW Artisan and Nugget Penman

  • I want to become a Labview programmer and I have no programmin​g experience where do I need to start to learn labview programmin​g

    I have had LabVIEW Basics 1 and 2 what do I do next?

    I always recommend the course of action that I took when I learned LabVIEW (in one week).
    Go get "LabVIEW for Everyone" and "Power Programming". They are readily available through NI's website, or through a good technical bookstore, or even a college bookstore. From there, just go through the example programs.
    I strongly recommend also learning good style. LabVIEW comes with a style guidelines book (which, apparently, only 6 people have ever read...) This will get you started on the road to good practices. LTR is also a good resource.
    Good luck.
    Oh, also, when you have gotten some experience, I recommend taking Advanced. I took it (three years after I learned LabVIEW) and was very happy with the course.

  • I would like to create a pop-up window appear from Labview Interface. In this window, I will have a slide control and an image taken from a camera. The main VI have to run while pop-up window is open. How can I do ?

    When I pushed a button, this pop-up window has to appear. There will be a slide control and a picture from a camera in this window. Is it possible to make appear this windows while main VI Interface continue to run ? How can I do this ? Thank you for your answers.
    Cyril.

    Here you go. This is simple example. Maybe not the best way, I am just
    beginner in LV and still not comfortable with data flow that much. I prefer
    events, so I would change this to use Event Structures.
    When you click on OK button on SliderMain, it opens Slider.vi. Now both
    windows are open and you can interact with both. Now if you click on OK
    again with Slider.vi open, you run into problems. Only thing I did was
    change VI properties of slider.vi, mainly window appearance.
    vishi
    "Cy" wrote in message
    news:[email protected]..
    > I would like to create a pop-up window appear from Labview Interface.
    > In this window, I will have a slide control and an image taken from a
    > camera. The main VI hav
    e to run while pop-up window is open. How can I
    > do ?
    >
    > When I pushed a button, this pop-up window has to appear. There will
    > be a slide control and a picture from a camera in this window. Is it
    > possible to make appear this windows while main VI Interface continue
    > to run ? How can I do this ? Thank you for your answers.
    > Cyril.
    [Attachment SliderMain.vi, see below]
    [Attachment Slider.vi, see below]
    Attachments:
    SliderMain.vi ‏16 KB
    Slider.vi ‏11 KB

Maybe you are looking for

  • Retrieving Freezed and Unfreezed data from a Single Report

    Dear All, I have a requirement where we have 2 types of users. 1. End User and 2. Super User 3. Intermediate Users We have source system data which will be retieved on a daily basis. Here Super user freeze the data ramdomly. We need a report to be ge

  • HT1473 I click "add file to library" and then the song i want, but it doesn't come up

    Im really POed at the new iTunes on so many levels. first, the iCloud makes all songs i bought when i was 11 and deleted when i was 13 again. me and my little sister share the same account, but we have different computers so we don't have each other'

  • Can you open multiple files using an advanced action?

    I have either Captivate 5.5 or Captivate 7 to work with. Currently my project is in 5.5. I have a button that I want to open three PDF files. I created an advanced action, selecting Open a new file/URL and selected the file name. Currently they are s

  • HTML tags in text-only e-mail notification (with HTML attachment)

    Greetings, Our "Purchase Order Review" e-mail notifications (as generated by the WF-Mailer) have HTML tags in the message body (which is "plain-text" text-only), with an HTML attachment. (The attachment looks good, and is what we are expecting.) All

  • Oracle 8i is coming for Linux July 5!!!

    Okay so they now have a release date for Linux version of Oracle 8i. Its July 5!!!!!!!!!!! Yippeee. I request that we all go to the corners of our rooms and stand there in silence for 20 minutes, in observance of this historical event! Mubashir null