I need to be able to save more then 150 characters in an extended attribute.  Where can this be configured to allow up to 200 characters?

Hello, we needed to do this for EA Free text field and expand to allow 20000 chars. Oracle gave us this solution:
/****** Object:  Index [PLM4P_COMMONEXTENDEDATTRIBUTETEXT_5]    Script Date: 10/12/2011 13:18:33 ******/
IF  EXISTS (SELECT * FROM sys.indexes WHERE object_id = OBJECT_ID(N'[dbo].[commonExtendedAttributeText]') AND name = N'PLM4P_COMMONEXTENDEDATTRIBUTETEXT_5')
DROP INDEX [PLM4P_COMMONEXTENDEDATTRIBUTETEXT_5] ON [dbo].[commonExtendedAttributeText] WITH ( ONLINE = OFF )
GO
--Update the database table:
ALTER TABLE commonExtendedAttributeText
ALTER COLUMN AttributeText NVARCHAR(max);
--Add back the index:
/****** Object:  Index [PLM4P_COMMONEXTENDEDATTRIBUTETEXT_5]    Script Date: 10/12/2011 13:18:33 ******/
IF NOT EXISTS (SELECT * FROM sys.indexes WHERE object_id = OBJECT_ID(N'[dbo].[commonExtendedAttributeText]') AND name = N'PLM4P_COMMONEXTENDEDATTRIBUTETEXT_5')
CREATE NONCLUSTERED INDEX [PLM4P_COMMONEXTENDEDATTRIBUTETEXT_5] ON [dbo].[commonExtendedAttributeText]
       [fkOwner] ASC,
       [pkid] ASC,
       [fkExtendedAttributeType] ASC,
       [fkRoot] ASC,
       [Comments] ASC
INCLUDE ( [AttributeText]) WITH (PAD_INDEX  = OFF, STATISTICS_NORECOMPUTE  = OFF, SORT_IN_TEMPDB = OFF, IGNORE_DUP_KEY = OFF, DROP_EXISTING = OFF, ONLINE = OFF, ALLOW_ROW_LOCKS  = ON, ALLOW_PAGE_LOCKS  = ON) ON [PRIMARY]
GO
--Update the UI control to allow for the length change:
--Modify \Web\WebCommon\Controls\ExtendedAttributesControls\ExtendedAttributeTextRow.ascx
--By updating the maxlen attribute of the <asp:TextBox to your max value. Eg: … maxlen="8000" />
Hope that helps!

Similar Messages

  • To change the approval limit for Extended attribute PO Value limits

    Hi,
    We are on SRM 4.0, in PPOMA_BBP for a local purchasing organisation we want to change the approval limit let us say from 100 to 50 but the system is presenting this field as non editable( In stabdard values sub screen)
    In Extended attribute tab in organisation structure after selecting the PO Value limits in SRM 4.0 we see two sub screens
    a) Standard values
    b) Local values
    We want to change the approval limit in standard values sub screen from 1000 to 500, which system is presenting as noneditable.
    Regrds
    Vivek

    Hi
    Refer these links.
    http://help.sap.com/saphelp_srm50/helpdata/en/5a/af5efc85d011d2b42d006094b92d37/frameset.htm
    http://help.sap.com/saphelp_srm50/helpdata/en/8b/4fa9585db211d2b404006094b92d37/content.htm
    http://help.sap.com/saphelp_srm50/helpdata/en/fa/fa7d3cb7f58910e10000000a114084/frameset.htm
    http://help.sap.com/saphelp_srm50/helpdata/en/7f/0fea380bfe6161e10000000a11402f/frameset.htm
    Incase it does not helps, pls let me know.
    Regards
    - Atul

  • User's Approval Limit  in Extended Attributes

    Dear SRMer's,
    System info:
    SRM 4.0.
    Problem Description:
    In PPOMA_BBP, I set my approval limit in the 'PO Value Limits' under Extended attributes to $1000.00 and added an approver for the SLApprover in Attributes tab.
    But when I create a shopping cart with value greater (>) than $1000.00,
    I dont see the SL approver on the approval flow and the approval flow says  no approval required.
    Please help.
    Thanks in advance,
    Best Regards,
    Bob

    Hi Bob,
    Deactivate your workflows for the shopping cart then check again.
    (or)
    follow the link below
    http://help.sap.com/saphelp_srm50/helpdata/en/79/ca013a0c88bc7ce10000000a114084/content.htm
    with regards,
    mahesh

  • Approval Limit of user - Extended Attributes

    Hello everyone,
           I would like to know the difference between standard values and local values for approval
    limit in extended attributes in PPOSA_BBP.  The standard value has 15000 AUD which is
    inherited by the organization unit under which the user is created.  Local value is 1000 AUD.
    What does this mean?  All users under the organization unit carry the same standard valu for
    approval limit but only head carries the local value which is 1000 AUD.
       Can anyone please answer to this.
    Thanks in Advance.

    Hi Priya,
    Even i checked in my system and i couldn't able to find much importance for standard value...system is considering only local values.....
    if you got the answer then please post it ...
    Thanks
    Ravi

  • How to set Max Rows when I search extended attribute in Admin Setting?

    When I search extended attributes in Admin Setting, the default max row is 500.
    Can I change the Max rows' Setting?
    Thanks

    We don't have a feature config for this in the core application, however you can adjust the 500 limit using a ready report.  Ready Reports is a solution pack that allows you to create saved searches in the form of reports.  You can get the ready reports solution pack in the latest extensibility pack.

  • How to increase the the max limit column in pivot view in BIEE 11G?

    Hi Experts,
    How to increase the the max limit column in pivot view in BIEE 11G?
    When the number of column exceed 256 in pivot view, it will generate the following error message as below:
    Exceeded configured maximum number of allowed output prompts, sections, rows, or columns.
    Error Details
    Error Codes: IRVLJWTA:OI2DL65P
    Location: saw.httpserver.processrequest, saw.rpc.server.responder, saw.rpc.server, saw.rpc.server.handleConnection, saw.rpc.server.dispatch, saw.threadpool.socketrpcserver, saw.threads
    SQL Issued: 13678~vid1ptgt0v5ubh39gesnauuhl6
    For example:
    ----------------Day
    Country-----20120101---20120102---..........20121231
    China--------10000---------20000----......

    Try increasing the Max Rows in Instanceconfig.xml
    Path:-Middleware\instances\instance1\bifoundation\OracleBIPresentationServices\instanceconfig.xml
    <ServerInstance>
    <Views>
    <Pivot>
    <MaxVisibleColumns>300</MaxVisibleColumns>
    <MaxVisiblePages>1000</MaxVisiblePages>
    <MaxVisibleRows>500</MaxVisibleRows>
    <MaxVisibleSections>25</MaxVisibleSections>
    <DefaultRowsDisplayed>30</DefaultRowsDisplayed>
    </Pivot>
    </Views>
    </ServerInstance>
    Try adding this in the config file and restart the services.
    Mark as correct if it is helpful.
    Thanks.

  • How to limit the number of characters entered in a JTextfield???

    Hello there,
    I have created a Text box using swing component JTextField and I want to limit the number of characters entered to 8 characters..how do i proceed with that?
    Thanks in advance!
    Joe

    Ty out this
    import com.sun.java.swing.text.*;
    //import javax.swing.text.*;
    public class JTextFieldLimit extends PlainDocument {
    private int limit;
    // optional uppercase conversion
    private boolean toUppercase = false;
    JTextFieldLimit(int limit) {
    super();
    this.limit = limit;
    JTextFieldLimit(int limit, boolean upper) {
    super();
    this.limit = limit;
    toUppercase = upper;
    public void insertString
    (int offset, String str, AttributeSet attr)
    throws BadLocationException {
    if (str == null) return;
    if ((getLength() + str.length()) <= limit) {
    if (toUppercase) str = str.toUpperCase();
    super.insertString(offset, str, attr);
    import java.awt.*;
    import com.sun.java.swing.*;
    //import javax.swing.*;
    public class tswing extends JApplet{
    JTextField textfield1;
    JLabel label1;
    public void init() {
    getContentPane().setLayout(new FlowLayout());
    label1 = new JLabel("max 10 chars");
    textfield1 = new JTextField(15);
    getContentPane().add(label1);
    getContentPane().add(textfield1);
    textfield1.setDocument
    (new JTextFieldLimit(10));

  • Cp leads to  "error processing extended attributes: Argument list too long"

    With certain PDF files to which I've added a lot of extended attributes (using Skim.app, a PDF reader/annotator which stores its notes in extended attributes), Chronosync and Finder drag-drops don't preserve extended attributes like they're supposed to (i.e. the notes aren't viewable on copies of the document). When I use cp to do they copying, the following message appears in system.log:
    error processing extended attributes: Argument list too long
    Googling it returns no results

    Hi Derick,
    error processing extended attributes: Argument list too long
    I have no idea why you get this error when copying a file...
    There is a max size for each extended attribute (about 3800bytes), and if I try to create (by using a simple C program) an attribute larger than this limit then I get "Argument list too long" error. But in your case you are trying to make a copy of an existing PDF file whose extended attributes should be smaller than the limit, of course (Skim has no magical power of creating an attribute larger than the limit; if the note is too large then I guess Skim just splits the note into two or more attributes).
    Q1: do you get the error only if you (try to) copy a PDF file with large notes? or you also get the error for a file with only small notes? How about a PDF file with many small notes?
    Q2: are you copying the PDF file to external volumes? If so, are you sure it is HFS+? What happens if you copy the PDF file to the same internal disk volume, for example
    cp your.pdf tmp.pdf
    PowerMacG4, PowerBookG4, iMac(C2D)   Mac OS X (10.4.9)  

  • Cannot create or replace : The specified extended attribute name was invalid.

    New problem arrived today. Trying to copy a file from 10.6 server with an XP (SP3) client. I get this error:
    Cannot create or replace (file name here): The specified extended attribute name was invalid.
    The contents of the file can be copied, but not the folder. Other files can be copied. There are no funny characters. The name is not too long. I propogated the permissions on the share and that had no affect. The problem exists on three different XP systems. Can't find extended properties that could be causeing a problem. Any ideas?

    Nikon just released a Firmware update today for the D750

  • Max limit reached for tablespace in SAP BW

    Hi Friends,
    We are having one SAP BW system on DB6, AIX...in that the max limit for tablespabe is 512GB, which is going to be exceeded soon...
    So it is planned to move some tables from tablespaces of aggregates i.e. FACTI, FACTD into new tablespaces...
    How can this be achieved?
    Thanks & Regards,
    Kunal Patel.

    He Kunal,
    As mentioned by Jens, you can use the DB2 9's Large RIDS (Larger Record Identifiers) support which significantly increases the size limit for table space.  SAP has a tools to do the conversion for you - OSS Note 11058956 (ABAP tool for activating large RIDs).
    Regards,
    -Beck

  • Limit the number of characters in Text Components

    I'm trying to limit the number of characters in text components. So I use the follow KeyListener:
    private class KeyHandler extends KeyAdapter{
    String oldText;
    private KeyHandler(){ }
    public void keyTyped(KeyEvent ev){
    String newText = textField.getText();
    System.out.println("Old text: " + this.oldText); //debug
    System.out.println("New text: " + newText); //debug
    if(newText.length() < limit){
    this.oldText = newText + ev.getKeyChar();
    }else{
    textField.setText(this.oldText);
    if(textField.getCaretPosition() + 1 > limit)
    textField.setCaretPosition(limit - 1);
    But the problem is that after that, the last key is typed in the component and the last key always appear.
    �Does anyone know the way for consume the key presses?
    Thank you

    (Belongs in the Swing forum.)
    The callback method keyTyped comes after keyPressed and keyReleased.
    The event.consume() should consume the event.
    Consider cut/copy/paste.
    Maybe a addPropertyChangeListener would be better?

  • Increasing max-streaming-connections-per-session has slow acknowledge response?

    Our application is a Flex GUI with a WebLogic Server (BlaseDS) on a private network.  We were originally using IE 6, but have upgraded to IE 8.
    I am trying to use publish/subscribe messaging to monitor lengthy processes on the server and received incremental data.  With 1 such process everything works fine.  But we want to allow the user to subscribe to more than 1 message destination.  So I increased the "max-streaming-connections-per-session" (default is 1) in the services-config.xml file
         <channel-definition id="process-notification-streaming-amf"
              class="mx.messaging.channels.StreamingAMFChannel">
              <endpoint url=https://{server.name}:{server.port}/{context.root}/messagebroker/streamingnotificationamf"
              class="flex.messaging.endpoints.StreamingAMFEndpoint"/>
              <properties>
                   <user-agent-settings>
                        <user-agent match-on="MSIE" kickstart-bytes="2048"
                             max-streaming-connections-per-session="3" />
                   </user-agent-settings>
              </properties>
         </channel-definition>
    If we leave max-streaming-connections-per-session as the default value of 1 and try to subscribe to another message destination we get an error indicating limit has been reached:
         [BlaseDS]Endpoint with id 'process-notification-streaming-amf' cannot grant streaming connection to FlexClient with id '7FFC82DE-etc ' because max-streaming-connections-per-session limit of '1' has been reached.
         We upgraded to IE8 as documentation indicates IE8 allows for an increase of max-streaming-connections-per-session, where IE 6 is limited to 1.  But increasing max-streaming-connections-per-session does not quite solve the problem.  We have 3 consumers; consumer1, consumer2, consumer3.  For each of these consumers, we add event listeners for MessageAckEvent.ACKNOWLEDGE and MessageEvent.MESSAGE.
         We call consumer1.subscribe().  When we receive the acknowledge message, we call consumer2.subscribe() (likewise with consumer3)
         The problem is it takes over 2 minutes to receive the acknowledge message from the call to consumer1.subscribe().  (With max-streaming-connections-per-session set to 1, the acknowledge message is received in a few seconds.)
         So, increasing max-streaming-connections-per-session removes the error about reaching a limit, but it appears to come with a cost of a big delay in a long delay on the call to subscribe?  Or is there something we are missing?

    I guess I will answer my own question.  Hopefully this will be useful to someone else in the future...
    The problem was coming from IE being limited to 1 connection by the registry.  The solution can be found at:
    http://support.microsoft.com/kb/282402
    I manually performed the steps to update the registry, though microsoft provides a "Fix It"; MicrosoftFixit50098.msi
    One other key element was to make sure to have kickstart-bytes="2048".

  • GTX 970 4g OV max limit...any problem with that??

    Hi, my 970 stock voltage is 1,212v and the ASIC is 65,4% (quite low) and vbios 84.04.2f.00.f1 ...in afterburner, despite there is a slider from 0 to +87v it seems like there is only 3 steps in voltage increase...for me they are:
    +0=1,212v
    +0 to +25mv=1,237v
    +25 to +87mv=1,256v
    -Is it SAFE to run the card at 1,256v 24/7 (obviously only when gaming)???
    -Why the slider is not applying the voltage in increments as slider indicates??, I mean, +37mv should be = +37mv voltage increase right??
    -And the most important thing...ONLY when voltage reach 1,256v I see in the graphs that the OV MAX LIMIT = 1 all the time (or most part) so I wonder is its SAFE to run the card with ov max limit =1???...according with the 1,256 I think there is lots of people running the card this way but not sure if ov max limit =1...
    Finally, I can run the card at 1486Mhz core (+170) and 3507Mhz memory (+0) at +25mv (1,237v) without the ov max limit at 1 should I leave the card just there???
    Many many thanks guys!!

    Quote from: watermanpc85 on 28-April-15, 19:22:29
    Thanks for the reply...I dont know hopw to upload the actual bios file but I recently updated the bios to the .186 version (latest)...now it says 84.04.36.00.f1.
    The vbios version is NV316MH.186 the numbers from gpu-z (84.04.36.00.f1) are irrelevant and do mean nothing.
    Quote from: watermanpc85 on 28-April-15, 19:22:29
    So I asume that there is not any problem by running the card with OV max limit=1 right???(as soon as the voltage is 1,256v)...anyway right now is a non sense for me because as soon as I increase voltage to 1,256v the card reaches max TDP limit and then it throtles...I would need to increase the TDP limit then...I have researched in the net but I cant find I CLEAR solution on how to increase the little 10% default...is there any "easy" way to do it??
    It just means that you reached the point where no more increases are possible.
    For increasing power limit further than is allowed by default a vbios mod is required that comes with a risk and voids warranty. If you are not familiar with vbios mods than there is no safe and easy way.

  • Adding Extended Attributes for Data Exporter

    Hi, I'm having trouble in getting an exported attribute to export within the new Data Exporter feature. In fact, once i alter the export schema to include the additional column (ext att), it won't write to that table at all.
    I am doing the following per the documentation from Sun, hopefully someone can point out the error of my way.
    First I alter the IDM Schema Configuration.xml file to include the additional User extended attribute.
    Next, I alter the model-export.xml file under model name='User' within WS_HOME to include the additional attribute here, my entry is as follows:
    <field name='employeeId'
    type='java.lang.String'
    introduced='8.0'
    max-length='50'
    forensic='User'
    queryable='true'
    exported='true'
    friendlyName='Employee Id'>
    <description>The Peoplesoft ID coming over</description>
    </field>
    Next, I go to the unzipped directory of IDM hence, \exporter and execute: "ant rebuild" and "ant deploy".
    The following takes place, The rebuild process regenerates my create and drop schema configuration scripts for MySQL. I run both scripts and
    my new column with the newly added extended attribute appears in the EXT_USER table. I also issue the proper permission commands on the tables
    I then undeploy my web application from Tomcat and re-deploy the web app.
    I start the server, log into IDM and go to the Data Exporter configuration page. Under the User data type, my extended attribute does not show up. Further, what once worked, the scheduler now does not write to the EXT_USER table and gives the following error when I believe IDM is starting up. I have no doubt that this is a clue as to why it is not working:
    "StartupServlet: Defining properties from web.xml
    Starting: Identity Server...
    ...Finished starting Startup Servlet
    {Model=User, employeeId=[], assignedRoles=[], idmManager=, businessPhone=[], location=[], MemberObjectGroups=[(id=#ID#Top)], lhdis=true, lhlocked=false, controlledObjectGroupsRule=, ACCT_CD=[], lastModDate=Tue Oct 21 16:44:21 PDT 2008, failedPasswordLoginAttemptsCount=0, description=, lastModifier=Configurator, role=[], divisionCode=[], companyMobilePhoneNumber=[], fullname=Anuradha Rao, employeeType=[], CompanyMailingAddress=[], objectClass=[Top, Object, Principal, User], hasCapabilities=false, questionLocked=false, [email protected], subtype=, managerId=[], sponsorId=[], contractorLocation=[], jobCode=[], locked=false, failedQuestionLoginAttemptsCount=0, xmlSize=936, res=[], repoMod=Tue Oct 21 16:44:21 PDT 2008, accountId=, textPagerEmailAddress=[], lastname=Rao, lastAuditorScan=, user_resources=[], creator=Configurator, id=#ID#54D7-:3AE94AA9C11:110E5685:2FC0FC1B3DEDDBF6, title=[], idmManagerNameNotFound=, faxNumber=[], facility=[], dis=0, lastPasswordUpdate=Wed Oct 01 15:31:47 PDT 2008, name=definabl, authType=, effectiveDate=[], createDate=Thu Sep 25 10:56:13 PDT 2008, jobTitle=[], prov=2, accounts=[], ControlledObjectGroups=[], costCenter=[], firstname=Anuradha, correlationKey=, primaryObjectClass=User, departmentName=[], roleInfo=[], accountType=, middleInitial=[], departmentId=[], displayName=, cubeNumber=[], disabled=true, }
    ex: java.lang.reflect.InvocationTargetException"
    java.lang.reflect.InvocationTargetException is thrown which leads me to believe that something is wrong with the javabean that is regenerated under the ant rebuild and the underlying User.hbm.xml file that regenerated as well. I can see from the User.hbm file that the new extended attribute has been added but this is as far as I have gotten. I really don't know where to go from here.
    Any and all help is extremely appreciated.
    Thank you. Dan

    Hi Nik,
    From section 1.4.2 of the install guide.
    https://docs.oracle.com/middleware/1213/edq/DQINS/planning.htm#DQINS5205
    EDQ Configuration Directories
    EDQ requires two configuration directories, which are separate from the EDQ Home (installation) directory that contains the program files. The configuration directories are:
    The base configuration directory: This directory contains default configuration data. Once EDQ is installed, the files in the base configuration directory must not be altered, renamed, or moved.
    The local configuration directory: This directory contains overrides to the default configuration. EDQ looks for overrides in this directory first, before looking in the base configuration directory. Files in the local configuration directory can be modified to customize or extend EDQ.
    The names and locations of the configuration directories are as follows:
    If you are using Oracle WebLogic Server, the Oracle installation wizard automatically creates and populates the configuration directories in the EDQ domain with the names of oedq.home (base configuration directory) and oedq.local.home (local configuration directory). An example installation path is: WLS_HOME/user_projects/domains/edq_domain/edq/oedq.home
    WLS_HOME/user_projects/domains/edq_domain/edq/oedq.local.home
    If you are using Apache Tomcat, you create the configuration directories manually in any location, with any names, and the configuration utility will populate them. You are prompted to create the directories during the installation instructions.
    Just copy flags.xml from your oedq.home casemanagement folder to your oedq.local.home casemanagement folder and edit the file accordingly.
    thanks,
    Nick

  • When I restore my Mac with Time Machine and then want to partition my disk, Disk Utility always says incorrect number of extended attributes

    When I need to restore my Mac from a time machine backup and then partition my hard disk (the disk inside the computer not the time machine disk), Disk Utility always says "Incorrect Number of Extended Attributes". I then boot into Recovery HD and run disk repair. The result? "The volume Macintosh HD appears to be OK". So then I reboot into normal OS and try the partition again, still Incorrect number of extended attributes. I have even tried /sbin/fsck -fy in single-user mode but it still says the volume is ok. I have tried partition my disk in the recovery HD and it still fails.
    Can anyone please help me solve this problem?

    Try something stronger, such as DiskWarrior or TechTool Pro.
    iMac refurb (27-inch Mid 2011), OS X Mavericks (10.9.4), SL & ML, G4 450 MP w/Leopard, 9.2.2