Input Controls pane - How to force Input Controls pane to visible on WebI?

We are planning to distribute WebI reports to our users. The reports would be scheduled daily and the users would get  an email containing a hyperlink to the Webi report. Upon clicking, the hyperlink it would  launch the WebI and refresh data to the latest instance of the report.
Is there a way to force the Input Controls pane to visible on this report when users click on the link?
Thanks

Hi Rohit,
I do not think this can be set in WebI. Nevertheless, I understand this suggestion as a very interesting enhancement for the tool. What about submitting it on Idea Place?
Thanks for the suggestion and your interest with input controls,
David.

Similar Messages

  • I was given an assingment, but have no idea where to begin. The assingment is to create a text file using notepad with all of my digital inputs and some how make those imputs show up on my digital indicators on my control pannel

    I was given an assingment, but have no idea where to begin. The assingment is to create a text file using notepad with all of my digital inputs and some how make those imputs show up on my digital indicators on my control pannel.
    When it was explained to me it didn't sound to hard of a task, I have no LabVIEW experience and the tutortial sucks.

    StevenD: FYI, I did NOT give you the one star rating. I would never do that!
    StevenD wrote:
    Ow. Someone is grumpy today.
    Well, this is an assignment, so it is probably homework.
    Why else would anyone give HIM such an assigment, after all he has no LabVIEW experience and the tutorials are too hard for him?
    This would make no sense unless all of it was just covered in class!
    This is not a free homework service with instant gratification.
    OK! Let's do it step by step. I assume you already have a VI with the digital indicators.
    "...but have no idea where to begin".
    open notepad.
    decide on a format, possibly one line per indicator.
    type the document.
    close notepad.
    open LabVIEW.
    Open the existing VI with all the indicators.
    (are you still following?)
    look at the diagram.
    Who made the program?
    Does the code make sense so far?
    Is it a statemachine or just a bunch of crisscrossed wires?
    Where do you want to add the file read?
    How should the file be read (after pressing a read button, at the start of the program ,etc.)
    See how far you get!
    Message Edited by altenbach on 06-24-2008 11:23 AM
    LabVIEW Champion . Do more with less code and in less time .

  • How to use the Control lines of a parallel port as Input lines to be read using Labview ?

    The details are :
    NI Software : LabVIEW
    Version : 5.0
    OS : Windows 95
    NI Hardware : N/A
    Drivers : N/A
    CPU : Pentium
    RAM : 48
    Vendor : darcom
    Customer Information :
    SPEL TESTING
    SPEL, INDIA
    [email protected]
    Ph: (91) 4114 53818
    We do not have any DAQ cards within the PC. We have the parallel port which is EPP and ECP compatible having the address 278h on LPT2 and we are trying use this port for reading 8bit data from an external circuit. We developed a vi program in Labview 5.0 to control the parallel port.We tried with the Data lines to send signals from PC to external device through this parallel port with the addr
    ess 278h (which
    is Data lines) and it works fine. We also tried using reading 4bit data from external
    device to PC through this port with the address 279h (which is Status lines) and it
    is also working fine.
    But it was not possible for us to read through Control lines whose address is 27Ah. Whereas when line printer (dot matrix printer) was
    connected, it was possible for us to take print out. Thus printer was working. This
    informed us that the control lines are all OK!
    Can you please clarify, how to use both control lines and status lines to read 8 bit data through this parallel port using the Labview software.

    There are several Knowledge Base entries about this on the NI site, but probably the most detailed document is on the Advanced Measurements (www.advmeas.com) website. Try looking at this page, I think you will find it useful.
    http://www.advmeas.com/goodies/parallelport.html

  • How to prohibite input in SI notation in numeric control?

    Input can be 3000, 3e+3, or 3k (SI).
    How to prohibite input in SI notation, for example "3k"?
    Thanks, Andrey.

    My first choice would be to simply use the Data Range to prevent out of range values regardless of how they are input.  If you really want to filter the allowed keys you need to use an Event Structure.  Here is an example, the string contains the allowed ascii characters, a separate case also allows Enter, Return and Delete, all other keys are blocked.   In the Disabled Case of the Diagram Disable Structure is simply a constant lookup table since you really only need to calculate it once unless something changes.
    Of course a fiendishly clever person could always paste an SI value in there.  (Why I would also rely on Data Range)

  • How to force digital input sample rate?

    Does anyone know how to force a Digital Input sample rate and/or tell Core Audio which conversion clock to use... internal or external? Apparently both things can be done from Pro Tools, but I don't have it.  My problem is locking onto an A/D converter's 48K Toslink output.  I can set 48K in 'Audio - Midi' setup and the audio is perfect, but a few seconds later  Core Audio returns to the default 44.1K.  I need to force it to stay at 48K, or clock on the signal rather than internal clock.

    Braver,
    Let me clarify a few things. First, the 6733 supports correlated digital I/O. This means that the digital operation does not have its own clock. You can correlate the digital operation with the AO clock, which will allow a digital operation up to the max AO rate. You can generate a pulse train with an onboard counter and use that as your digital clock source. Also, you can use a completely external clock source to achieve the max digital rate of 10MHz. The knowledge base, linked below, points you to a couple of examples that ship with LabVIEW. Be sure and read the documentation associated with each example.
    Knowlege Base
    As for
    the example CDI Single Point clocked by Counter (E).vi, notice how the output of...

  • LOV Control is going to next Input Field

    Hi all,
    when i clikc LOV icon on my form the control is going to next input field.second one should have partial trigger with LOV field .Due to partial trigger am facing this problem .I recreated the binidings also.But it is not working.
    please help me in this .It is very urgent .
    Ravi.

    Hi ,
    Am giving all my code details .Please help me .
    1.LOV INput Field with name PRMID:
    <af:inputListOfValues id="prmIdId"
    popupTitle="Search and Select: #{bindings.PrmId.hints.label}"
    value="#{bindings.PrmId.inputValue}"
    label="#{bindings.PrmId.hints.label}"
    model="#{bindings.PrmId.listOfValuesModel}"
    required="#{bindings.PrmId.hints.mandatory}"
    columns="#{bindings.PrmId.hints.displayWidth}"
    shortDesc="#{bindings.PrmId.hints.tooltip}"
    autoSubmit="false" editMode="select"
    binding="#{backingBeanScope.backing_rcsPartner.prmIdTxt}">
    <f:validator binding="#{bindings.PrmId.validator}"/>
    </af:inputListOfValues>
    2.Input Field HQID having partial trigger to prmID
    <af:inputText value="#{bindings.HqId.inputValue}"
    label="#{bindings.HqId.hints.label}"
    required="#{bindings.HqId.hints.mandatory}"
    columns="#{bindings.HqId.hints.displayWidth}"
    maximumLength="#{bindings.HqId.hints.precision}"
    shortDesc="#{bindings.HqId.hints.tooltip}" id="it1"
    binding="#{backingBeanScope.backing_rcsPartner.hqidTxt}"
    partialTriggers="prmIdId">
    <f:validator binding="#{bindings.HqId.validator}"/>
    </af:inputText>
    3. My Page Definition Page having both PRMID,HQID
    <?xml version="1.0" encoding="UTF-8" ?>
    <pageDefinition xmlns="http://xmlns.oracle.com/adfm/uimodel"
    version="11.1.1.56.60" id="RcsPartnerPageDef"
    Package="fragments">
    <parameters/>
    <executables>
    <variableIterator id="variables"/>
    <iterator Binds="RcsPartnerSetupViewTbl" RangeSize="100"
    DataControl="AdminHandlerAMDataControl"
    id="RcsPartnerSetupViewTblIterator"/>
    <searchRegion Criteria="__ImplicitViewCriteria__"
    Customizer="oracle.jbo.uicli.binding.JUSearchBindingCustomizer"
    Binds="RcsPartnerSetupViewTblIterator"
    id="ImplicitViewCriteriaQuery"/>
    </executables>
    <bindings>
    <attributeValues IterBinding="RcsPartnerSetupViewTblIterator"
    id="LastUpdateUser">
    <AttrNames>
    <Item Value="LastUpdateUser"/>
    </AttrNames>
    </attributeValues>
    <attributeValues IterBinding="RcsPartnerSetupViewTblIterator"
    id="CreateDts">
    <AttrNames>
    <Item Value="CreateDts"/>
    </AttrNames>
    </attributeValues>
    <attributeValues IterBinding="RcsPartnerSetupViewTblIterator"
    id="LastUpdateDts">
    <AttrNames>
    <Item Value="LastUpdateDts"/>
    </AttrNames>
    </attributeValues>
    <tree IterBinding="RcsPartnerSetupViewTblIterator"
    id="RcsPartnerSetupViewTbl">
    <nodeDefinition DefName="com.hp.rebates.grs.model.services.ui.queries.RcsPartnerSetupView"
    Name="RcsPartnerSetupViewTbl0">
    <AttrNames>
    <Item Value="PrmId"/>
    <Item Value="HqId"/>
    <Item Value="LastUpdateUser"/>
    <Item Value="CreateDts"/>
    <Item Value="LastUpdateDts"/>
    <Item Value="Name"/>
    </AttrNames>
    </nodeDefinition>
    </tree>
    <action IterBinding="RcsPartnerSetupViewTblIterator" id="Delete"
    RequiresUpdateModel="false" Action="removeCurrentRow"/>
    <action IterBinding="RcsPartnerSetupViewTblIterator" id="CreateInsert"
    RequiresUpdateModel="true" Action="createInsertRow"/>
    <action id="Commit" RequiresUpdateModel="true" Action="commitTransaction"
    DataControl="AdminHandlerAMDataControl"/>
    <action id="Rollback" RequiresUpdateModel="false"
    Action="rollbackTransaction"
    DataControl="AdminHandlerAMDataControl"/>
    <listOfValues StaticList="false"
    IterBinding="RcsPartnerSetupViewTblIterator" Uses="LOV_PrmId"
    id="PrmId"/>
    <attributeValues IterBinding="RcsPartnerSetupViewTblIterator" id="Name">
    <AttrNames>
    <Item Value="Name"/>
    </AttrNames>
    </attributeValues>
    <attributeValues IterBinding="RcsPartnerSetupViewTblIterator" id="HqId">
    <AttrNames>
    <Item Value="HqId"/>
    </AttrNames>
    </attributeValues>
    </bindings>
    </pageDefinition>

  • Control and design applying ramp input and plotting polar coordinates state space

    Hi
    I am trying to do a fairly simple state space task with Control Design and Simulation toolbox, however I am quite new at using this toolbox and need some help :-)
    I want to simulate a MIMO system of a 2-DOF robot arm. The robot arm consists of two links, the first link can rotate arround its origo at its end, and the next link moves inside the first link, in and out.
    So the two outputs is define as
    r (radius), which is the distance to the end-effector of the robot, and
    theta, which is the angular postion of the robot arm
    FYI, the two inputs are the currents send to the two motors controlling each link.
    I have set up A, B, C and D matrices in the attached VI file and putted it inside a simulation loop.
    Now I need help :-)
    I want to simulate the system when a ramp input is applied to the two inputs and plot the two outputs in a polar graph to show the end-effectors position when the system is just "let loose". The result should be a spiral (this is verified in MATLAB simulink).
    So please, I need help setting up the VI to do the above, can anyone help?
    Best regards
    Simon
    MSc. Eng.
    Message Edited by SCMAJA on 10-16-2009 11:21 AM
    LabVIEW 8.6 / 2009 / 2010
    Vision Development Module 8.6 / 2009 / 2010
    VBAI 3.6 / 2010
    Attachments:
    2 DOF robot with ramp input, polar coordinates plot, state space.vi ‏49 KB

    Hello Simon,
    The error comes from your Ramp Input. Since your system is MIMO, you would need to feed in a vector input to the system.
    I've changed your VI and attached here~!
    Andy Chang
    National Instruments
    LabVIEW Control Design and Simulation
    Attachments:
    MIMO Robot VI.vi ‏76 KB

  • HT4437 Trying to use airplay from my iPad to my TV.........when airplay code comes on screen how do I input the number on my iPad?

    I am trying to use my iPad with Airplay on my TV.  When I attempt to link up with TV a code appears on the screen.  Where and how do I input the code?

    Setup Apple TV with iPad
    1. Setup Apple TV
    (a) Connect cables and power cord
    (b) Turn on TV and select Input
    (c) Configure Apple TV
    2. Setup Home Sharing on iPad
    Settings>Music/Video>Home Sharing
    3. Setup Home Sharing on Apple TV
    Settings>Computer>Turn on Home Sharing. Enter Apple ID and Password
    4. Pair Apple TV with Remote Control
    General>Remotes>Pair Apple Remote

  • How to insert tabstrip control in module pool screen painter

    Hi all!
    plz tell e how to use tabstrip control in module pool screen painter.Also plz give me an example program using tabstrip control.

    To insert tabstrip just open layout of screen and press on the tabstrip button there .
    Use this souce code further to activate it .
    CONTROLS tabstrip TYPE TABSTRIP.
    DATA: okcode TYPE sy-ucomm,
    dynnr TYPE sy-dynnr,
    flag type flag,
    active like tabstrip-activetab .
    call SCREEN 100.
    *& Module USER_COMMAND_0100 INPUT
    text
    MODULE USER_COMMAND_0100 INPUT.
    data: lv_okcode type syucomm.
    lv_okcode = okcode.
    clear okcode.
    case lv_okcode.
    WHEN 'TAB1'.
    dynnr = '0110'.
    WHEN 'TAB2'.
    dynnr = '0120'.
    WHEN 'TAB3'.
    dynnr = '0130'.
    WHEN 'TAB4'.
    dynnr = '0140'.
    WHEN 'TAB5'.
    "check authorization, if authorization fails
    flag = 'X'. "set the global flag
    active = 'TAB1'. "store active tab in global variable
    dynnr = '0110'. "set the screen number
    WHEN 'BACK' or 'EXIT'.
    leave program.
    ENDCASE.
    IF lv_okcode(3) = 'TAB'.
    tabstrip-activetab = lv_okcode.
    ENDIF.
    ENDMODULE. " USER_COMMAND_0100 INPUT
    *& Module STATUS_0100 OUTPUT
    text
    MODULE STATUS_0100 OUTPUT.
    SET PF-STATUS 'MAIN'.
    SET TITLEBAR 'xxx'.
    IF tabstrip-activetab IS INITIAL OR
    dynnr IS INITIAL.
    tabstrip-activetab = 'TAB1'.
    dynnr = '0110'.
    ENDIF.
    "set the activetab explicilty here
    if flag eq 'X'. "from authorization failure
    tabstrip-activetab = active. "'TAB1'
    clear flag.
    endif.
    ENDMODULE. " STATUS_0100 OUTPUT

  • How to adjust a "control array" size

    I have a program that creates a digital PWM signal with variable duty cycle. The duty cycle changes every 50 ms, but the overall wave frequency stays at a frequency determined by the user. I have the VI attatched.
    My problem is this...I need to be able to control the overall cycle time. This means the size of my array of duty cycles needs to adjust based on the cycle time (i.e. a cycle time of 1 second would require 20 of the 50 ms slots, while a 1.3 second cycle would need 26).
    I currently have only 4 slots in my array, meaning the total cycle time is .2 s. I understand how to manually add and remove elements to the array, but I can't figure out how to add a control to it so that the array size changes automatically, allowing much quicker entry of data. As of now I can make it work, it just takes super long to add or delete array elements. The ideal situaton would have a constant control for cycle time divided by 50 that would change the array size.
    I can't find any info on this, and I think I even saw a post asking that this kind of feature be added. I'm relatively new to this program.
    Thanks
    Solved!
    Go to Solution.
    Attachments:
    var_duty_cycle.vi ‏25 KB

    Currently, your VI is a one-shot deal. What you need is a state machine that updates the pct duty cycle array control as a function of the frequency while the current I/O code is idle.
    I would use an array of clusters, where each cluster contains e.g. a sequence number, a duty cycle, and a string as element label. Show the scrollbar and set the size whenever the relevant inputs change. Do you want to reset the current setting when the number changes or do you want to retain the current settings as much as possible? You could just use the existing values, reshape to the larger or smaller size, and write it back to the control via a local variable. Set all elements  except the percent to disabled so they act as indicators and cannot be changed by the user.
    (You also need to program around it if the operator tries to manually add more elements. A better solution would be this idea, so vote for it .)
    Some more general comments bout your code:
    Why do you use extended precision floating point. All your waits are internally just integers. EXT makes no sense
    There is a primitive for 1/x. However, you could just do a 1000/x and eliminate the multiplication afterwards. SInce you are dealing with integers, you can even do the division using quotient&remainder. Depending on the allowed frequency range there are possibly no orange data needed at all.
    Make the diagram constant representation match the rest of the code.
    The pulses/50ms indicator belongs before the loop. No need to recalculate and refresh it over and over from the same input values.
    LabVIEW Champion . Do more with less code and in less time .

  • How to use table control in LSMW

    Hello All,
    I have requirement to use LSMW , in my using transaction have table control ,I need to pass values in table control . how to use table control in LSMW .Can any one give me the solution for this.
    Best regards,
    Satya.

    Note: The recording function records a fixed screen sequence. It cannot be used for migrating data containing a variable number of items or for transactions with dynamic screen sequences!
    Tip: It is possible to create a recording via SHDB, generate a program out of this recording, and adopt the program to your needs and registrate the program to be able to use it in LSMW.
    That’s means, for creation of project and WBS Elements is not possible through
    1. LSMW-BDC (For both CJ01 and CJ20n)
    2. LSMW-BAPI (Method: Maintain is not listed )
    3. LSME-Standard Batch Direct Input.
    It’s possible through programmatically(SE38.) either using BAPI Or BDC.
    Thanks,

  • How to use table control in bdc, plz somebody tell me.

    Hi Gurus,
    Ples tell me
    how to use table control in bdc, plz somebody tell me.
    And send Sample CODE also. Thnaks in advance.

    hi,
    Table control / step loop in BDC
    Steploop and table contol is inevitable in certain transactions. When we run BDC for such transactions, we will face the situation: how many visible lines of steploop/tablecontrol are on the screen?
    Although we can always find certain method to deal with it, such as function code 'NP', 'POPO', considering some extreme situation: there is only one line visible one the screen, our BDC program should display an error message. (See transaction 'ME21', we you resize your screen to let only one row visible, you can not enter mutiple lines on this screen even you use 'NP')
    we can determine the number of visible lines on Transaction Screen from our Calling BDC program.
    Demo ABAP code has two purposes:
    1. how to determine number of visible lines and how to calculte page number;
    (the 'calpage' routine has been modify to meet general purpose usage)
    2. using field symbol in BDC program, please pay special attention to the difference
    in Static ASSIGN and Dynamic ASSIGN.
    Step1: go to screen painter to display the screen 121, then we can count the fixed line on this screen, there is 7 lines above the steploop and 2 lines below the steploop, so there are total 9 fixed lines on this screen. This means except these 9 lines, all the other line is for step loop.
    Then have a look at steploop itselp, one entry of it will occupy two lines.
    (Be careful, for table control, the head and the bottom scroll bar will possess another two fixed lines, and there is a maximum number for table line)
    Now we have : FixedLine = 9
    LoopLine = 2(for table control, LoopLine is always equal to 1)
    Step2: go to transaction itself(ME21) to see how it roll page, in ME21, the first line of new page is always occupied by the last line of last page, so it begin with index '02', but in some other case, fisrt line is empty and ready for input.
    Now we have: FirstLine = 0
    or FirstLine = 1 ( in our case, FirstLine is 1 because the first line of new page is fulfilled)
    Step3: write a subroutine calcalculating number of pages
    (here, the name of actual parameter is the same as formal parameter)
    global data: FixedLine type i, " number of fixed line on a certain screen
    LoopLine type i, " the number of lines occupied by one steploop item
    FirstLine type i, " possbile value 0 or 1, 0 stand for the first line of new " scrolling screen is empty, otherwise is 1
    Dataline type i, " number of items you will use in BDC, using DESCRIBE to get
    pageno type i, " you need to scroll screen how many times.
    line type i, " number of lines appears on the screen.
    index(2) type N, " the screen index for certain item
    begin type i, " from parameter of loop
    end type i. " to parameter of loop
    *in code sample, the DataTable-linindex stands for the table index number of this line
    form calpage using FixedLine type i (see step 1)
    LoopLine type i (see step 1)
    FirstLine type i (see step 2)
    DataLine type i ( this is the item number you will enter in transaction)
    changing pageno type i (return the number of page, depends on run-time visible line in table control/ Step Loop)
    changing line type i.(visible lines one the screen)
    data: midd type i,
    vline type i, "visible lines
    if DataLine eq 0.
    Message eXXX.
    endif.
    vline = ( sy-srows - FixedLine ) div LoopLine.
    *for table control, you should compare vline with maximum line of
    *table control, then take the small one that is min(vline, maximum)
    *here only illustrate step loop
    if FirstLine eq 0.
    pageno = DataLine div vline.
    if pageno eq 0.
    pageno = pageno + 1.
    endif.
    elseif FirstLine eq 1.
    pageno = ( DataLine - 1 ) div ( vline - 1 ) + 1.
    midd = ( DataLine - 1 ) mod ( vline - 1).
    if midd = 0 and DataLine gt 1.
    pageno = pageno - 1.
    endif.
    endif.
    line = vline.
    endform.
    Step4 write a subroutine to calculate the line index for each item.
    form calindex using Line type i (visible lines on the screen)
    FirstLine type i(see step 2)
    LineIndex type i(item index)
    changing Index type n. (index on the screen)
    if FirstLine = 0.
    index = LineIndex mod Line.
    if index = '00'.
    index = Line.
    endif.
    elseif FirstLine = 1.
    index = LineIndex mod ( Line - 1 ).
    if ( index between 1 and 0 ) and LineIndex gt 1.
    index = index + Line - 1.
    endif.
    if Line = 2.
    index = index + Line - 1.
    endif.
    endif.
    endform.
    Step5 write a subroutine to calculate the loop range.
    form calrange using Line type i ( visible lines on the screen)
    DataLine type i
    FirstLine type i
    loopindex like sy-index
    changing begin type i
    end type i.
    If FirstLine = 0.
    if loopindex = 1.
    begin = 1.
    if DataLine <= Line.
    end = DataLine.
    else.
    end = Line.
    endif.
    elseif loopindex gt 1.
    begin = Line * ( loopindex - 1 ) + 1.
    end = Line * loopindex.
    if end gt DataLine.
    end = DataLine.
    endif.
    endif.
    elseif FirstLine = 1.
    if loopindex = 1.
    begin = 1.
    if DataLine <= Line.
    end = DataLine.
    else.
    end = Line.
    endif.
    elseif loop index gt 1.
    begin = ( Line - 1 ) * ( loopindex - 1 ) + 2.
    end = ( Line - 1 ) * ( loopindex - 1 ) + Line.
    if end gt DataLine.
    end = DataLine.
    endif.
    endif.
    endif.
    endform.
    Step6
    using field sysbol in your BDC, for example: in ME21, but you should calculate each item will correponding to which index in steploop/Table Control
    form creat_bdc.
    field-symbols: , , .
    data: name1(14) value 'EKPO-EMATN(XX)',
    name2(14) value 'EKPO-MENGE(XX)',
    name3(15) value 'RM06E-SELKZ(XX)'.
    assign: name1 to ,
    name2 to ,
    name3 to .
    do pageno times.
    if sy-index gt 1
    *insert scroll page ok_code"
    endif.
    perform calrange using Line DataLine FirstLine sy-index
    changing begin end.
    loop at DataTable from begin to end.
    perform calindex using Line FirstLine DataTable-LineIndex changing Index.
    name1+11(2) = Index.
    name2+11(2) = Index.
    name3+12(2) = Index.
    perform bdcfield using DataTable-matnr.
    perform bdcfield using DataTable-menge.
    perform bdcfield using DataTable-indicator.
    endloop.
    enddo.
    example 1
    BDC table control is an area on the screen in which you can display data in tabular form. You process it using a loop. Table controls are comparable to step loop tables. While a table control consists of a single definition row, step loop blocks may extend over more than one row. Table controls are more flexible than step loops, and are intended to replace them
    When you need to handle a scenario like in sales order,it may contain more than one material,if you have more than one material We have to use table control,it will have number of columns and number of rows.
    Table controls allow you to enter, display, and modify tabular data easily on the screen
    Check this code,
    PARAMETERS: file1 LIKE rlgrap-filename.
    *Internal Table Declarations
    DATA: BEGIN OF itab OCCURS 0,
    matnr(18) TYPE c, "MaterialNumber
    werks(4) TYPE c, "Plant
    vdatu(10) TYPE c, "Valid From Date
    bdatu(10) TYPE c, "Valid To Date
    lifnr(10) TYPE c, "Vendor Number
    ekorg(4) TYPE c, "Purchasing Organization
    feskz TYPE c, "Fixed
    autet TYPE c, "MRP Indicator
    END OF itab.
    DATA: bdcdata LIKE TABLE OF bdcdata WITH HEADER LINE.
    *VARIABLES Declarations
    DATA: wa1 LIKE LINE OF itab. "Workarea for ITAB
    DATA: n TYPE i, "Check
    count TYPE i.
    DATA: cnt(2), "Counter
    wa(15). "Workarea to hold concatenatedvalue
    DATA v_msg(100).
    DATA: flag.
    DATA: file TYPE string.
    *Initialization event
    INITIALIZATION.
    *At-selection-screen event
    *To provide Input help for file name
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR file1.
    CALL FUNCTION 'F4_FILENAME'
    EXPORTING
    program_name = syst-cprog
    dynpro_number = syst-dynnr
    IMPORTING
    file_name = file1.
    *START-OF-SELECTION EVENT
    START-OF-SELECTION.
    MOVE file1 TO file.
    CALL FUNCTION 'GUI_UPLOAD'
    EXPORTING
    filename = file
    filetype = 'ASC'
    has_field_separator = 'X'
    TABLES
    data_tab = itab
    EXCEPTIONS
    file_open_error = 1
    file_read_error = 2
    no_batch = 3
    gui_refuse_filetransfer = 4
    invalid_type = 5
    no_authority = 6
    unknown_error = 7
    bad_data_format = 8
    header_not_allowed = 9
    separator_not_allowed = 10
    header_too_long = 11
    unknown_dp_error = 12
    access_denied = 13
    dp_out_of_memory = 14
    disk_full = 15
    dp_timeout = 16
    OTHERS = 17.
    IF sy-subrc <> 0.
    MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
    WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
    ENDIF.
    *To populate BDCDATA and start data transfer
    LOOP AT itab .
    To validate Plant range
    IF itab-werks = '1000' OR itab-werks = '2000'
    OR itab-werks = '1008'.
    AT NEW werks.
    CLEAR: n.
    cnt = 1.
    PERFORM bdc_dynpro USING 'SAPLMEOR' '0200'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'EORD-MATNR'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_field USING 'EORD-MATNR'
    itab-matnr.
    PERFORM bdc_field USING 'EORD-WERKS'
    itab-werks.
    PERFORM bdc_dynpro USING 'SAPLMEOR' '0205'.
    CONCATENATE 'EORD-EKORG(' cnt ')' INTO wa.
    PERFORM bdc_field USING 'BDC_CURSOR'
    wa.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=BU'.
    ENDAT.
    IF n = 12.
    READ TABLE bdcdata WITH KEY fval = '=BU'.
    bdcdata-fval = '=NS'.
    MODIFY bdcdata INDEX sy-tabix TRANSPORTING fval.
    PERFORM bdc_dynpro USING 'SAPLMEOR' '0205'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'EORD-VDATU(01)'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=BU'.
    cnt = 2.
    n = 2.
    ENDIF.
    CONCATENATE 'EORD-VDATU(' cnt ')' INTO wa.
    PERFORM bdc_field USING wa
    itab-vdatu.
    CONCATENATE 'EORD-BDATU(' cnt ')' INTO wa.
    PERFORM bdc_field USING wa
    itab-bdatu.
    CONCATENATE 'EORD-LIFNR(' cnt ')' INTO wa.
    PERFORM bdc_field USING wa
    itab-lifnr.
    CONCATENATE 'EORD-EKORG(' cnt ')' INTO wa.
    PERFORM bdc_field USING wa
    itab-ekorg.
    CONCATENATE 'RM06W-FESKZ(' cnt ')' INTO wa.
    PERFORM bdc_field USING wa
    itab-feskz.
    CONCATENATE 'EORD-AUTET(' cnt ')' INTO wa.
    PERFORM bdc_field USING wa
    itab-autet.
    IF n <> 12.
    n = cnt.
    ENDIF.
    cnt = cnt + 1.
    AT END OF werks.
    CALL TRANSACTION 'ME01' USING bdcdata
    UPDATE 'S'
    MODE 'A'.
    CLEAR:bdcdata,bdcdata[].
    CALL FUNCTION 'FORMAT_MESSAGE'
    EXPORTING
    id = sy-msgid
    lang = 'EN'
    no = sy-msgno
    v1 = sy-msgv1
    v2 = sy-msgv2
    v3 = sy-msgv3
    v4 = sy-msgv4
    IMPORTING
    msg = v_msg.
    WRITE:/ v_msg.
    CLEAR: bdcdata,bdcdata[],flag.
    ENDAT.
    ENDIF.
    ENDLOOP.
    Start new screen *
    FORM bdc_dynpro USING program dynpro.
    CLEAR bdcdata.
    bdcdata-program = program.
    bdcdata-dynpro = dynpro.
    bdcdata-dynbegin = 'X'.
    APPEND bdcdata.
    ENDFORM.
    Insert field values
    FORM bdc_field USING fnam fval.
    IF NOT fval IS INITIAL.
    CLEAR bdcdata.
    bdcdata-fnam = fnam.
    bdcdata-fval = fval.
    APPEND bdcdata.
    ENDIF.
    CLEAR wa.
    ENDFORM.
    Sample code 2
    THis is example to upload the Bank details of the Vendor which has the TC.
    REPORT zprataptable2
    NO STANDARD PAGE HEADING LINE-SIZE 255.
    DATA : BEGIN OF itab OCCURS 0,
    i1 TYPE i,
    lifnr LIKE rf02k-lifnr,
    bukrs LIKE rf02k-bukrs,
    ekorg LIKE rf02k-ekorg,
    ktokk LIKE rf02k-ktokk,
    anred LIKE lfa1-anred,
    name1 LIKE lfa1-name1,
    sortl LIKE lfa1-sortl,
    land1 LIKE lfa1-land1,
    akont LIKE lfb1-akont,
    fdgrv LIKE lfb1-fdgrv,
    waers LIKE lfm1-waers,
    END OF itab.
    DATA : BEGIN OF jtab OCCURS 0,
    j1 TYPE i,
    banks LIKE lfbk-banks,
    bankl LIKE lfbk-bankl,
    bankn LIKE lfbk-bankn,
    END OF jtab.
    DATA : cnt(4) TYPE n.
    DATA : fdt(20) TYPE c.
    DATA : c TYPE i.
    INCLUDE bdcrecx1.
    START-OF-SELECTION.
    CALL FUNCTION 'WS_UPLOAD'
    EXPORTING
    filename = 'C:\first1.txt'
    filetype = 'DAT'
    TABLES
    data_tab = itab.
    CALL FUNCTION 'WS_UPLOAD'
    EXPORTING
    filename = 'C:\second.txt'
    filetype = 'DAT'
    TABLES
    data_tab = jtab.
    LOOP AT itab.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0100'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'RF02K-KTOKK'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_field USING 'RF02K-LIFNR'
    itab-lifnr.
    PERFORM bdc_field USING 'RF02K-BUKRS'
    itab-bukrs.
    PERFORM bdc_field USING 'RF02K-EKORG'
    itab-ekorg.
    PERFORM bdc_field USING 'RF02K-KTOKK'
    itab-ktokk.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0110'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'LFA1-LAND1'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_field USING 'LFA1-ANRED'
    itab-anred.
    PERFORM bdc_field USING 'LFA1-NAME1'
    itab-name1.
    PERFORM bdc_field USING 'LFA1-SORTL'
    itab-sortl.
    PERFORM bdc_field USING 'LFA1-LAND1'
    itab-land1.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0120'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'LFA1-KUNNR'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0130'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'LFBK-BANKN(01)'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=ENTR'.
    cnt = 0.
    LOOP AT jtab WHERE j1 = itab-i1.
    cnt = cnt + 1.
    CONCATENATE 'LFBK-BANKS(' cnt ')' INTO fdt.
    PERFORM bdc_field USING fdt jtab-banks.
    CONCATENATE 'LFBK-BANKL(' cnt ')' INTO fdt.
    PERFORM bdc_field USING fdt jtab-bankl.
    CONCATENATE 'LFBK-BANKN(' cnt ')' INTO fdt.
    PERFORM bdc_field USING fdt jtab-bankn.
    IF cnt = 5.
    cnt = 0.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0130'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'LFBK-BANKS(01)'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=P+'.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0130'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'LFBK-BANKN(02)'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=ENTR'.
    ENDIF.
    ENDLOOP.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0130'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'LFBK-BANKS(01)'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=ENTR'.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0210'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'LFB1-FDGRV'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_field USING 'LFB1-AKONT'
    itab-akont.
    PERFORM bdc_field USING 'LFB1-FDGRV'
    itab-fdgrv.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0215'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'LFB1-ZTERM'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0220'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'LFB5-MAHNA'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0310'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'LFM1-WAERS'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_field USING 'LFM1-WAERS'
    itab-waers.
    PERFORM bdc_dynpro USING 'SAPMF02K' '0320'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'RF02K-LIFNR'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=ENTR'.
    PERFORM bdc_dynpro USING 'SAPLSPO1' '0300'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=YES'.
    PERFORM bdc_transaction USING 'XK01'.
    ENDLOOP.
    PERFORM close_group.
    Header file:
    1 63190 0001 0001 0001 mr bal188 b in 31000 a1 inr
    2 63191 0001 0001 0001 mr bal189 b in 31000 a1 inr
    TC file:
    1 in sb 11000
    1 in sb 12000
    1 in sb 13000
    1 in sb 14000
    1 in sb 15000
    1 in sb 16000
    1 in sb 17000
    1 in sb 18000
    1 in sb 19000
    1 in sb 20000
    1 in sb 21000
    1 in sb 22000
    2 in sb 21000
    2 in sb 22000
    Regards

  • How to save Custom control records ?

    Hi guru ,
    1. How to save Custom control records module pool program ?
    I wrote multiple lines of record in custom control
    Who to save that records ?
    thanking you.
    Regards,
    Subash.

    REPORT  ZCUSTOMC.
    CLASS event_handler DEFINITION.
      PUBLIC SECTION.
        METHODS: handle_f1 FOR EVENT f1 OF cl_gui_textedit
                 IMPORTING sender,
                 handle_f4 FOR EVENT f4 OF cl_gui_textedit
                 IMPORTING sender.
    ENDCLASS.
    DATA: ok_code LIKE sy-ucomm,
          save_ok LIKE sy-ucomm.
    DATA: init,
          container TYPE REF TO cl_gui_custom_container,
          editor    TYPE REF TO cl_gui_textedit.
    DATA: event_tab TYPE cntl_simple_events,
          event     TYPE cntl_simple_event.
    DATA: line(256) TYPE c,
          text_tab LIKE STANDARD TABLE OF line,
          field LIKE line.
    DATA handle TYPE REF TO event_handler.
    START-OF-SELECTION.
      line = 'First line in TextEditControl'.
      APPEND line TO text_tab.
      line = '----
      APPEND line TO text_tab.
      line = '...'.
      APPEND line TO text_tab.
      CALL SCREEN 100.
    MODULE status_0100 OUTPUT.
      SET PF-STATUS 'SCREEN_100'.
      IF init is initial.
        init = 'X'.
        CREATE OBJECT: container EXPORTING container_name = 'TEXTEDIT',
                       editor    EXPORTING parent = container,
                       handle.
        event-eventid = cl_gui_textedit=>event_f1.
        event-appl_event = ' '.                     "system event
        APPEND event TO event_tab.
        event-eventid = cl_gui_textedit=>event_f4.
        event-appl_event = 'X'.                     "application event
        APPEND event TO event_tab.
        CALL METHOD: editor->set_registered_events
                     EXPORTING events = event_tab.
        SET HANDLER handle->handle_f1
                    handle->handle_f4 FOR editor.
      ENDIF.
      CALL METHOD editor->set_text_as_stream EXPORTING text = text_tab.
    ENDMODULE.
    MODULE cancel INPUT.
      LEAVE PROGRAM.
    ENDMODULE.
    MODULE user_command_0100 INPUT.
      save_ok = ok_code.
      CLEAR ok_code.
      CASE save_ok.
        WHEN 'INSERT'.
          CALL METHOD editor->get_text_as_stream IMPORTING text = text_tab.
        WHEN 'F1'.
          MESSAGE i888(sabapdocu) WITH text-001.
        WHEN OTHERS.
          MESSAGE i888(sabapdocu) WITH text-002.
          CALL METHOD cl_gui_cfw=>dispatch.      "for application events
          MESSAGE i888(sabapdocu) WITH text-003.
      ENDCASE.
      SET SCREEN 100.
    ENDMODULE.
    CLASS event_handler IMPLEMENTATION.
      METHOD handle_f1.
        DATA row TYPE i.
        MESSAGE i888(sabapdocu) WITH text-004.
        CALL METHOD sender->get_selection_pos
             IMPORTING from_line = row.
        CALL METHOD sender->get_line_text
             EXPORTING line_number = row
             IMPORTING text = field.
        CALL METHOD cl_gui_cfw=>set_new_ok_code   "raise PAI for
             EXPORTING new_code = 'F1'.           "system events
        CALL METHOD cl_gui_cfw=>flush.
      ENDMETHOD.
      METHOD handle_f4.
        DATA row TYPE i.
        MESSAGE i888(sabapdocu) WITH text-005.
        CALL METHOD sender->get_selection_pos
             IMPORTING from_line = row.
        CALL METHOD sender->get_line_text
             EXPORTING line_number = row
             IMPORTING text = field.
        CALL METHOD cl_gui_cfw=>flush.
      ENDMETHOD.
    ENDCLASS.
    aniruddh

  • How do I program controls for my robot?

    Currently I'm trying to Program a robot to move according to the control of a person using a controller. I am having trouble getting the robot to response to the controller is there any tutorials or help threads out there I can use to help fix my problem.
    I have found in labview how to program what each controller input is suppose to tell the robot but when tested the robot doesn't respond. I believe I'm missing code to read the messages from the controller and move the robot accordingly but have been unable to figure out how to input the code required or if that is the true problem.
    If anyone can help in some way or another it be much appreciated.
    Thank You in advance.

    Yes!  The NI Robotics Module is built for this.  LabVIEW is very good at measurement and test-taking, so it makes reading from your sensors much easier and supports all kinds of sensors, including vision systems.  It then streamlines the control process based on the inputs.  Here's a white paper with more in-depth information about what the NI Robotics Module has to offer.
    http://www.ni.com/white-paper/11564/en/#toc7
    Julian R.
    Applications Engineer
    National Instruments

  • HOW TO MAKE TABLE CONTROL NON EDITABLE

    hi all
    how to make table control non editable
    Thanks & Regards
    harsha

    Hi,
    Try this code in the PBO inside the module in the LOOP...ENDLOOP.
       IF SY-TCODE EQ 'ZEMPLDISPLAY'.
        LOOP AT SCREEN.
         if screen-name eq 'column1' or screen-name eq 'column2'.  "Give the names of the columns in the table control
          SCREEN-INPUT = '0'.
          MODIFY SCREEN.
        endif.
        ENDLOOP.
      ENDIF.
    Or you can go the Layout of the table control in Change mode and for every column's attributes, make it 'Output' only field. Check  'Output only' field.

Maybe you are looking for

  • Not able to take print a report directly to the printer

    Hi All, Can anyone help me to print a report directly to the printer?. Currently, I am viewing the reports in the screen and then taking print of that report. If anyone knows the solution for this, please give me the feedback immediately. It is very

  • All iPhoto events appear empty in "Event" view

    When I view my iPhoto 11 library by "Events", I get the usual listing of all my events, and I am able to scroll through the preview pictures at this level within the individual small Event icon. The key photo shows as normal.  However, if I double cl

  • DBMS_SCHEDULER and Shell Script on 10.2.0.1

    Hi All My env, Oracle 10.2.0.1 and OS is Solaris. My script can run on OS that is work without error that contain create file, delete file, call sqlplus, function to get value from database and return to OS variables. In shell script some code as bel

  • I cannot use "InfoBus Data Form wizard"

    I can't use "InfoBus Data Form wizard", because it doesn not apper in anywhare of my JDeveloper 3.1, on Win NT 4.0/SP5. Any help will be much appreciated.

  • Sales order:allow partial  delivery

    please explain the  concept of  partial delivery in   the  sales  order.