Layout default option on the selection screen

I have given a Select Layout box on the Selection screen of my ALV report. How can I pass the default layout value, already set in the report to the box on the selection screen as the default value.

DATA: RS_VARIANT LIKE DISVARIANT.
SELECTION-SCREEN : BEGIN OF BLOCK B10 WITH FRAME TITLE TEXT-024.
    PARAMETERS       : PA_VARI  TYPE SLIS_VARI.
SELECTION-SCREEN : END OF BLOCK B10.
FORM ALV_VARIANT_F4  CHANGING P_PA_VARI.
  DATA: "RS_VARIANT LIKE DISVARIANT,
         NOF4       TYPE C,
         G_REPID    TYPE SY-REPID.
  MOVE SY-REPID TO G_REPID.
  CLEAR NOF4.
  LOOP AT SCREEN.
    IF SCREEN-NAME    = PA_VARI.
      IF SCREEN-INPUT = 0.
        NOF4 = 'X'.
      ENDIF.
    ENDIF.
  ENDLOOP.
  RS_VARIANT-REPORT   = G_REPID.
  RS_VARIANT-USERNAME = SY-UNAME.
  CALL FUNCTION 'REUSE_ALV_VARIANT_F4'
    EXPORTING
      IS_VARIANT = RS_VARIANT
      I_SAVE     = 'A'
    IMPORTING
      ES_VARIANT = RS_VARIANT
    EXCEPTIONS
      OTHERS     = 1.
  IF SY-SUBRC = 0 AND NOF4 EQ SPACE.
    PA_VARI = RS_VARIANT-VARIANT.
  ENDIF.
ENDFORM.                    " ALV_VARIANT_F4
Following code is used to get the Layout selection box on the selection screen.

Similar Messages

  • Dynamic Selection option in the selection screen

    Hi ,
    I have a requirement like this ....
    The user wants some fields to be default available in the selection screen. But they also want to be able to select the data based on additional fields (all the remaining fields ) which they want to see in the dynamic selection .
    The basic list for selections should be limited to the fields listed in the specifications provided to me and the remaining fields should be made available through the dynamic selection option.
    In the transaction FBL3N , this facility is provided.
    Kindly help me with this..
    thanks,
    Sumit .

    Hi Sumit,
    To include dynamic selection check this sample code.
    TYPE POOLS DECLARATIONS FOR VALUE REQUEST MANAGER AND ICONS
    TYPE-POOLS : vrm,
                 icon.
    *SELECTION SCREEN FIELDS
    TABLES : sscrfields.*GLOBAL DECLARATIONS
    DATA : flag TYPE c,
          tablename(10),
          mmtable LIKE dd02l-tabname,
          sdtable LIKE dd02l-tabname,
          hrtable LIKE dd02l-tabname.*DECLARATIONS FOR SELECTION SCREEN STATUS
    DATA it_ucomm TYPE TABLE OF sy-ucomm.***********SELECTION-SCREENS**********************
    SELECTION-SCREEN BEGIN OF BLOCK blk1 WITH FRAME.*FOR DYNAMIC DISPLAY OF MODULES
    PARAMETERS :  pa RADIOBUTTON GROUP rad USER-COMMAND com MODIF ID mod,
                  pb RADIOBUTTON GROUP rad MODIF ID rad,
                  pc RADIOBUTTON GROUP rad MODIF ID cad.SELECTION-SCREEN SKIP.**TO INCLUDE DYNAMIC ICONS
    SELECTION-SCREEN COMMENT 2(6) text_001.*DYNAMIC LIST BOX BASED ON USER SELECTIONS
    PARAMETERS one AS LISTBOX VISIBLE LENGTH 20  MODIF ID mod.
    PARAMETERS two AS LISTBOX VISIBLE LENGTH 20   MODIF ID rad.
    PARAMETERS three AS LISTBOX VISIBLE LENGTH 20 MODIF ID cad.SELECTION-SCREEN END OF BLOCK blk1.*DISPLAY DYNAMIC PUSHBUTTON ON APP TOOLBAR ON USER CLICKS
    SELECTION-SCREEN: FUNCTION KEY 1,
                      FUNCTION KEY 2,
                      FUNCTION KEY 3.**EVENT ON SELECTION SCREEN FOR OUTPUT DISPLAY
    AT SELECTION-SCREEN OUTPUT.*CLICK OF FIRST RADIO BUTTON
      IF pa = 'X'.
        sscrfields-functxt_01 = 'Materials Management'.
        WRITE icon_plant AS ICON TO text_001.
    *CODE TO GET DYNAMICS BASED ON THE SELECTED RADIO
        LOOP AT SCREEN.
          IF screen-group1 = 'MOD'.
            screen-intensified = '1'.
            screen-active = 1.
            screen-display_3d = '1'.
            MODIFY SCREEN.
          ENDIF.
          IF screen-group1 = 'RAD'.
            screen-intensified = '0'.
            screen-active = 0.
            screen-display_3d = '0'.
            MODIFY SCREEN.
          ENDIF.
          IF screen-group1 = 'CAD'.
            screen-intensified = '0'.
            screen-active = 0.
            screen-display_3d = '0'.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
      ENDIF.*CLICK OF SECOND RADIO
      IF pb = 'X'.
        sscrfields-functxt_02 = 'Sales And Distribution'.
        WRITE icon_ws_ship AS ICON TO text_001.
        LOOP AT SCREEN.
          IF screen-group1 = 'RAD'.
            screen-intensified = '1'.
            screen-active = 1.
            screen-display_3d = '1'.
            MODIFY SCREEN.
          ENDIF.
          IF screen-group1 = 'MOD'.
            screen-intensified = '0'.
            screen-active = 0.
            screen-display_3d = '0'.
            MODIFY SCREEN.
          ENDIF.
          IF screen-group1 = 'CAD'.
            screen-intensified = '0'.
            screen-active = 0.
            screen-display_3d = '0'.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
      ENDIF.*CLICK OF THIRD RADIO
      IF pc = 'X'.
        sscrfields-functxt_03 = 'Human Resources'.
        WRITE icon_new_employee AS ICON TO text_001.
        LOOP AT SCREEN.
          IF screen-group1 = 'RAD'.
            screen-intensified = '0'.
            screen-active = 0.
            screen-display_3d = '0'.
            MODIFY SCREEN.
          ENDIF.
          IF screen-group1 = 'MOD'.
            screen-intensified = '0'.
            screen-active = 0.
            screen-display_3d = '0'.
            MODIFY SCREEN.
          ENDIF.
          IF screen-group1 = 'CAD'.
            screen-intensified = '1'.
            screen-active = 1.
            screen-display_3d = '1'.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
      ENDIF.*CUSTOMISING THE TOOLBARS OF THE SELECTION SCREEN
    *WITH F8 BUTTON DISABLED  APPEND :  'PRIN' TO it_ucomm,
                'SPOS' TO it_ucomm,
                'ONLI' TO it_ucomm.  CALL FUNCTION 'RS_SET_SELSCREEN_STATUS'
        EXPORTING
          p_status  = sy-pfkey
        TABLES
          p_exclude = it_ucomm.
    **EVENT ON THE SELECTION
    AT SELECTION-SCREEN.* LIST BOX ONE VALUES
      CASE one.
        WHEN '1'.
          mmtable = 'MARC'.
        WHEN '2'.
          mmtable = 'MARA'.
        WHEN '3'.
          mmtable = 'MARD'.
        WHEN '4'.
          mmtable = 'MARM'.
      ENDCASE.* LIST BOX TWO VALUES
      CASE two.
        WHEN '1'.
          sdtable = 'VBAK'.
        WHEN '2'.
          sdtable = 'VBAP'.
        WHEN '3'.
          sdtable = 'VBUK'.
        WHEN '4'.
          sdtable = 'VBUP'.
      ENDCASE.* LIST BOX THREE VALUES
      CASE three.
        WHEN '1'.
          hrtable = 'PA0001'.
        WHEN '2'.
          hrtable = 'PA0006'.
        WHEN '3'.
          hrtable = 'PA0022'.
        WHEN '4'.
          hrtable = 'PA0008'.
      ENDCASE.*VALUES FOR CLICK OF THE PUSHBUTTON ON APP TOOLBAR
    *AND ENABLING THE BUTTONS TO PERFORM F8
      CASE sscrfields-ucomm.
        WHEN 'FC01'.
          tablename = mmtable.
          sscrfields-ucomm = 'ONLI'.
        WHEN 'FC02'.
          tablename = sdtable.
          sscrfields-ucomm = 'ONLI'.
        WHEN 'FC03'.
          tablename = hrtable.
          sscrfields-ucomm = 'ONLI'.
      ENDCASE.*INITIALIZATION EVENT
    INITIALIZATION.*VALUES ASSIGNED TO DROPDOWNLISTS IN THE SUBROUTINES
      PERFORM f4_value_request_pa.
      PERFORM f4_value_request_pb.
      PERFORM f4_value_request_pc.*START OF SELECTION EVENT
    START-OF-SELECTION.*SUBROUTINE FOR OUTPUT
      PERFORM output.*&----------------------------------------------------------------*
    *&      Form  f4_value_request_PA
    *       text
    *SUBROUTINE TO PROVIDE DROPDOWN VALUES TO LIST1
    FORM f4_value_request_pa.  DATA: l_name TYPE vrm_id,
            li_list TYPE vrm_values,
            l_value LIKE LINE OF li_list.  l_value-key = '1'.
      l_value-text = 'Plant Data for Material'.
      APPEND l_value TO li_list.
      CLEAR l_value.  l_value-key = '2'.
      l_value-text = 'General Material Data'.
      APPEND l_value TO li_list.
      CLEAR l_value.  l_value-key = '3'.
      l_value-text = 'Storage Location Data for Material'.
      APPEND l_value TO li_list.
      CLEAR l_value.  l_value-key = '4'.
      l_value-text = 'Units of Measure for Material'.
      APPEND l_value TO li_list.
      CLEAR l_value.
      l_name = 'ONE'.  CALL FUNCTION 'VRM_SET_VALUES'
        EXPORTING
          id              = l_name
          values          = li_list
        EXCEPTIONS
          id_illegal_name = 1
          OTHERS          = 2.
      IF sy-subrc <> 0.
        MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
                WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
      ENDIF.ENDFORM. " f4_value_request_tabname*&----------------------------------------------------------------*
    *&      Form  f4_value_request_PB
    *       text
    *SUBROUTINE TO PROVIDE DROPDOWN VALUES TO LIST2FORM f4_value_request_pb.  DATA: l_name TYPE vrm_id,
            li_list TYPE vrm_values,
            l_value LIKE LINE OF li_list.  l_value-key = '1'.
      l_value-text = 'Sales Document: Header Data'.
      APPEND l_value TO li_list.
      CLEAR l_value.  l_value-key = '2'.
      l_value-text = 'Sales Document: Item Data'.
      APPEND l_value TO li_list.
      CLEAR l_value.  l_value-key = '3'.
      l_value-text = 'Sales Document:Header Status'.
      APPEND l_value TO li_list.
      CLEAR l_value.  l_value-key = '4'.
      l_value-text = 'Sales Document: Item Status'.
      APPEND l_value TO li_list.
      CLEAR l_value.
      l_name = 'TWO'.
      CALL FUNCTION 'VRM_SET_VALUES'
        EXPORTING
          id              = l_name
          values          = li_list
        EXCEPTIONS
          id_illegal_name = 1
          OTHERS          = 2.
      IF sy-subrc <> 0.
        MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
                WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
      ENDIF.
    ENDFORM. " f4_value_request_PB*&----------------------------------------------------------------*
    *&      Form  f4_value_request_PC
    *       text
    *SUBROUTINE TO PROVIDE DROPDOWN VALUES TO LIST3FORM f4_value_request_pc.  DATA: l_name TYPE vrm_id,
            li_list TYPE vrm_values,
            l_value LIKE LINE OF li_list.  l_value-key = '1'.
      l_value-text = 'HR Master :Infotype 0001 (Org. Assignment)'.
      APPEND l_value TO li_list.
      CLEAR l_value.  l_value-key = '2'.
      l_value-text = 'Address Infotype 0006'.
      APPEND l_value TO li_list.
      CLEAR l_value.  l_value-key = '3'.
      l_value-text = 'Education Infotype 0022'.
      APPEND l_value TO li_list.
      CLEAR l_value.  l_value-key = '4'.
      l_value-text = 'Basic Pay Infotype 0008'.
      APPEND l_value TO li_list.
      CLEAR l_value.
      l_name = 'THREE'.
      CALL FUNCTION 'VRM_SET_VALUES'
        EXPORTING
          id              = l_name
          values          = li_list
        EXCEPTIONS
          id_illegal_name = 1
          OTHERS          = 2.
      IF sy-subrc <> 0.
        MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
                WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
      ENDIF.
    ENDFORM. " f4_value_request_PC
    *&      Form  OUTPUT
    *       text
    *      -->P_TABLENAME  text
    *fINAL OUTPUT
    FORM output.  DATA p_table(10).  p_table = tablename.*popup to display teh selected table and
    *Continue button is clicked
      CALL FUNCTION 'POPUP_TO_DISPLAY_TEXT'
        EXPORTING
          titel        = 'User Selections '
          textline1    = p_table
          textline2    = 'is the Selected table'
          start_column = 25
          start_row    = 6.*assigning the table value in p_table to the
    * Table in SE16 transaction by explicitly calling
      SET PARAMETER ID 'DTB' FIELD p_table.
      CALL TRANSACTION 'SE16'.
    ENDFORM.                    "OUTPUT
    Regards,
    Manoj Kumar P

  • Changing of default values on the selection screen dynamically

    Hi,
          I have 2 radiobuttons R_A & R_B and i have one text field like P_TEXT. Based on selection of radio button i have to change the default values in P_TEXT on the selection screen. like if i select R_A i have to display P_TEXT = 'A'. if i select R_B then it has to display P_TEXT = 'B'. I tried like as below
    in AT SELECTION-SCREEN OUPUT EVENT.
                 IF R_A = 'X'
                   P_TEXT = 'A'.
                 ELSEIF R_B= 'B'.
                   P_TEXT = 'B'.
                 ENDIF.
            But it's not working. it is working only for first radio button. when i select second radio button it is not giving the second value. can any one tell the sol.
    Tks in advance.

    Hi Pammi,
    Use this code, its working:-
    PARAMETERS : r_a RADIOBUTTON GROUP gp1 DEFAULT 'X' USER-COMMAND rb,
                 r_b RADIOBUTTON GROUP gp1,
                 p_text(20).
    "we use user command with the radiobutton so that some event is occured in order to call AT SELECTION-SCREEN OUTPUT.
    AT SELECTION-SCREEN OUTPUT.
      IF r_a = 'X'.
        p_text = 'Hello'.
      ELSEIF r_b = 'X'.
        p_text = 'Hi'.
      ENDIF.
    In the above case 'AT SELECTION-SCREEN OUTPUT' will act as PBO of the selection screen and will change value of selection text as per condition.
    Hope this solves your problem.
    Thanks & Regards,
    Tarun Gambhir

  • What is meant by single entry-multiple options in the selection screen

    hi,
      please let me know what is the meant by 'single entry-multiple options' in a selection screen.
    thanks in advance

    Hi Surya,
    Nomally we use to declare Selct options like
    <b>select-options : s_var for mara-matnr.</b>
    here you can enter range of values for material number like 000 to 9999999999.
    but if you want single entry multiple option you need to give no-intervals options when the select option will behave like parameter .. when you cannot give range of values but you can give multiple values for a single field.
    for single entry-multiple options  write the select option like this
    and see the diffrence.
    <b>select-options : s_var for mara-matnr NO INTERVALS.</b>
    here cannot enter low and high range for matnr but you can enter mulitple values for select option..you can enter only low range values..
    Please reward if usefull..
    Thanks,
    Gokul

  • F4 option in the selection screen

    Hi All,
    I have defined VBRK-VBELN as select-options with no range and no-extensoin in the selection screen.
    The F4 option for this field displays all the Billing Documents (VBELN) from VBRK table.
    Now i would like to modify the F4 option in such a way that the system should just display the Billing Documents (VBRK-VBELN) pertaining to a particular Distribution Channel (VBRK-VTWEG).
    How to make the modifications for such requirement?
    Kindly Help me.....
    Regards
    Pavan

    Hi Pavan
               you can create your own custom elementary search help thru se11 and assign it to the select-options. you can use a view to create this search help and in that view you need to restrict the vbeln based on ur distribution channel
    select-option: so_vbeln for vbak-vbeln matchcode object <Elm serch help name>.
    http://help.sap.com/saphelp_nw04/helpdata/en/cf/21ee5f446011d189700000e8322d00/content.htm
    Award points if helpful

  • Displaying Plant as F4 option in the selection screen according to the User Authorization

    Hi all,
    In the selection screen, I need to display the list of plants as F4 search help that the user has authorization.
    How I need to check from the table.
    Please provide me the exact table name where I can get the list of plants that the user has authorization.
    Thanks in Advance.
    Regards,
    karthik

    Hi Madan,
    Thanks for your reply.
    As of now Plant entered in selection screen is validated for authorization like below.
    authority-check object 'M_MATE_WRK'
          id 'ACTVT' field '02'
          id 'WERKS' field p_werks.
       if sy-subrc <> 0.
         message text-010 type c_e.
         exit.
       endif.
    But they are in need of Plants in F4.
    Regards,
    Karthik

  • Regarding the select-options on the selection screen

    In select-options the low and high fileds must be displayed in the following explained manner...
    How to get the low field value as 1000 (default) and it must be in display mode (not possible to change the value) and high field must be empty and it has to allow us to enter the value.
    How to get this....?
    Please help me in this regard...
    Thank u very much
    Regards..
    Nagarjuna

    TABLES : mara.
    SELECT-OPTIONS: s_matnr FOR mara-matnr.
    INITIALIZATION.
      S_MATNR-SIGN  = 'I'.  "inclusion
      S_MATNR-OPTION = 'BT'    "between
      S_MATNR-LOW = '1000'.
      APPEND s_matnr.
    AT SELECTION-SCREEN OUTPUT.
      LOOP AT SCREEN.
        IF screen-name EQ 'S_MATNR-LOW'.
          screen-input = 0.
          MODIFY screen.
          EXIT.
        ENDIF.
      ENDLOOP.
    Reward if Helpful.

  • Text for block and select option on the selection screen of Logical Databas

    Hi,
    I have copied a standard program (RFBELJ10) which is making use of LDB (BRF) and created a custom program. Now, the requirement is to add a selection screen option to the custom report and do some validation on the data extracted. I have added the select option and provided a text (lets say "Segment") to it using menu path Goto --> Text Elements --> Selection Texts and activated. But this text is not displayed on the screen when i execute the report. It is showing the string which i used while defining the select option.
    Also i need to provide a frame and title to it. but its not displayed.
    i have written the following code for that:
    SELECTION-SCREEN: BEGIN OF BLOCK seg WITH FRAME TITLE text-h01. " Segment
    SELECT-OPTIONS: s_segmnt FOR faglflexa-segment. " Segment
    SELECTION-SCREEN: END OF BLOCK seg.
    Could you please help me in getting the texts displayed for fram and the select option?
    Thanks,
    Phani

    Solved the problem. I have maintained the text in German. So, when I execute the report in english, it is not displaying the text. I have translated the texts to English and is working fine now.

  • Default value on the selection screen.

    Hi All,
    We have a field on the selection that is Sales Organisation.
    Now for this field we want the default value coming from the User Parameters.
    i.e On SAP menu under SYSTEM there is User profile, In that user profile if you go to OWN DATA, There is tab called parameters.
    Here VKO Parameter ID the sales Organisation is defined. They want this value to come as default on the screen.
    Please help out how can this be done.

    In the INITIALIZATION write the code as below.
    get paramater id 'VKO' into field p_sfiled.
    here p_field is your selection screen field.
    Reward points if useful
    Regards,
    Nageswar

  • Default options across the PR screen

    Guys, When i open the PR screen it defaults to the "PR for Low Value Materials" type of requisition. I want the screen to default to the "PR for Materials" screen.

    Hi,
    Just refer this thread you will get the complete idea
    ME51N change the default document type

  • Collective search on the Select-options field on the selection screen

    Hello experts,
                       I have a Y program and a selection screen for it. I have to get the BKPF-BELNR in the search help list. Since the table is too bulky to get all the documents form it. I thought I might need a condition of company code for fetching the documents. I have company code on the selection screen, but if I press F4, on the BELNR, my select-options internal table for <b>company code</b> is remains initial. I think for F4 events the values doesn't get populated in the internal tables, not sure.
                       Can you tell me, how to get the company code entered on the selection screen, on the F4 event. Or If this doesn't work, will collective search help solve my problem? If yes, Please let me know, which function module I can use to add a collective search to my select-options on the selection screen.
    Thanks,
    Ganesh Khumse.
    Points will be rewarded!

    Hi
    do like this
    TYPES : BEGIN OF ST_OBJID_SH,
             OTYPE TYPE HRP1000-OTYPE,
             OBJID TYPE HRP1000-OBJID,
            END OF ST_OBJID_SH.
    DATA : IT_OBJID_SH TYPE STANDARD TABLE OF ST_OBJID_SH.
    DATA : WA_OBJID_SH TYPE ST_OBJID_SH.
    ***********SELECTION SCREEN DESIGN***********************
    SELECTION-SCREEN BEGIN OF BLOCK B1 WITH FRAME TITLE TEXT-001.
    *SELECT-OPTIONS : S_OTYPE FOR HRP1001-OTYPE NO INTERVALS .
    SELECT-OPTIONS : S_OBJID FOR HRP1001-OBJID NO INTERVALS .
    SELECT-OPTIONS : DATE FOR SY-DATUM NO-EXTENSION OBLIGATORY.
    SELECTION-SCREEN END OF BLOCK B1.
    **********END OF SELECTION SCREEN DESIGN*****************
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR S_OBJID-LOW.
    IF S_OBJID IS NOT INITIAL.
        SELECT OTYPE OBJID FROM HRP1000
                     INTO TABLE IT_OBJID_SH
                     WHERE OTYPE = 'D'.
    IF SY-SUBRC EQ 0.
    SEARCH HELP FOR QUALIFICATION.
        CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
          EXPORTING
                 DDIC_STRUCTURE         = ' '
            RETFIELD               =  'OBJID'
                 PVALKEY                = ' '
           DYNPPROG               = SY-REPID
           DYNPNR                 = SY-DYNNR
           DYNPROFIELD            = 'S_OBJID'
                 STEPL                  = 0
                 WINDOW_TITLE           =
                 VALUE                  = ' '
           VALUE_ORG              = 'S'
                 MULTIPLE_CHOICE        = ' '
                 DISPLAY                = ' '
                 CALLBACK_PROGRAM       = ' '
                 CALLBACK_FORM          = ' '
                 MARK_TAB               =
               IMPORTING
                 USER_RESET             =
          TABLES
            VALUE_TAB              =  IT_OBJID_SH
                 FIELD_TAB              =
                 RETURN_TAB             = RETURN_TAB
                 DYNPFLD_MAPPING        =
               EXCEPTIONS
                 PARAMETER_ERROR        = 1
                 NO_VALUES_FOUND        = 2
                 OTHERS                 = 3
        IF SY-SUBRC <> 0.
              MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
                      WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
        ENDIF.
      ENDIF.

  • HR-ABAP: Defaulting Radio Button on Selection Screen of PNP LDB

    Hi all,
    I am using PNP LDB (Logical Database) for program which is used for Payroll Results.
    Now I have a requirement wherein it is necessary to select 'Up to today' as default on the selection screen.
    We are having 4.7C version of SAP. I tried following code in INITIALIZATION event:
    Initializing Selection Screen Data Selection Option to 'Up To Today'
    INITIALIZATION:
      MOVE:  'X'    TO    pnptimr4, " This is the option which I want as Default selection.
             space  TO    pnptimr1,
             space  TO    pnptimr2,
             space  TO    pnptimr3,
             space  TO    pnptimr5,
             space  TO    pnptimr6.
    But still I dont see this Radiobutton getting selected as Default selection while running the program.
    By Default it selects Option : 'Other Period' (pnptimr6).
    Any Idea how to resolve this ??
    Regards,
    Avinash

    hi...
    When the INITIALIZATION event occurs, you can set default values for the selection screen.
    The fields for the data selection are defined in structure QPPNP.
    Possible values for field PNPTIMED are:
    D     =      Today (key date)
    M     =     Current month
    Y     =     Current year
    P     =     To current date
    F     =     From today (from current date)
    The person selection fields are defined in include program DBPNPSEL. They are internal tables that must be filled using APPEND.
    so in intialization you have to write code as
    PNPTIMED : P.
    so up date will be defaulted in selection screen.
    award points if helpful.

  • I have mapped the fields on the selection-screen  to the BDC on transaction

    I have mapped the fields on the selection-screen  to the BDC on transaction F110.
    When I am selecting a particular any value in select-option on the selection screen, it is giving some default value and the value given by me,for example:
    Payment methods:C
    but in BDC recording for F110 Payment methods:IEQC when the programs is running in foreground mode.
    how can I rectify it?

    This is because payment methods may be a table and what you see IEQC is actually, I for include, EQ for equal and C as your payment method. This is standard structure for ranges or select-options. You can use variable-low which will give you only C.

  • Making sy-datum available in the selection screen.

    Hi All,
    This is a query regarding for eg: tcode wpo1. We want to schedule the program in
    background with a variant.
    The variants should have all our field but delivery date as sy-datum which is default in the current program.
    How do we do. I kind of tried a lot of options on the selection screen variant  saving.  Nothing seems to be solving my issue.
    Kindly suggest.
    Rgds,
    Anu.

    Hi ,,
    In the tcode WPO1,
    while saving as variant,in variant attributes,  For the field "Delievry Date " ,
    give the following :
    " Selection Variable = D; Dynamic Date calculation"
    "NAme of Variable = Current date",
    then save it .
    Now you can see only the current date i.e sy-datum even with in the variant when you execute WPO1.
    this will work fine as i faced the same problem.
    revert me back if u find any difficulty
    reward points if you find it helpful.
    regards
    Naveen

  • The selection screen cannot choose the multiple values at first instance?

    Hi All,
       I have 2 select-options on the selection screen as follows>>
    SELECT-OPTIONS :
                       s_subusr FOR pa0105-usrid NO INTERVALS OBLIGATORY,   
                      s_period FOR vbak-erdat   NO-EXTENSION OBLIGATORY.   
    When I try to enter multiple values by clicking the multiple option button when noting is entered as input on the selection screen.I get a error"Make entry in all required fields".
    But when I enter a value on the selection screen input for s_subusr and then enter value in s_period and then click on multiple option button I am able to see the multi-option Popup.Now I can enter multiple Values.
    Please can anyone help me to enter the values on the multiple option Pop-up whenever the user want?
    Regards,
    Shashank.

    HI
    OBLIGATORY means you have to enter the values , with out filling that values and if you click any thing it will show an error message saying that fill alla required fields
    so if you want you can remove that
    or if you want to keep that OBLIGATORY then fill some values 1st in that select-options and clcik on multiple entries button then it won't show any error
    <b>Reward if usefull</b>

Maybe you are looking for

  • Appletv mini usb port not working

    Plugged in mini usb into Macbook and its not reading the appletv. Any thoughts?

  • Custom HTML or JS in Column Headers in Answers

    All, I am primarily a web developer, but a co-worker asked me how a site was doing a particular effect (they had set the title parameter of a node, and it was showing up like a tooltip). He wanted to set it up on the column header of an Answer, so th

  • [How - to] Install in a click from AUR webpages

    Here I little hack I coded to install packages directly from the AUR frontend. Needed: - yaourt - Firefox with greasemonkey (https://addons.mozilla.org/addon/748) or any greasemonkey-scripts accepting browser. Steps: 1. Create a small bash script cal

  • Fiscal Year Calendar - OB29

    Hello SAP Gurus, Could you please take a look at the below fiscal year calendar and let me know if it looks correct. I am seeing a problem in my transferred assets when the are transferred in period 11. It's not calculating correctly. I am thinking i

  • Handling files with different sizes of content (please help)!

    Hi, I have a written a program to tell customers how much certain apartments are to rent. It asks the reader to input a floor number and the number of bedrooms in the apartment. I then returns the price. The contents of the file look like this: 0 400