LMS 4.2.3 HUM poller Reports

Hi All,
The hum poller reports generated were saved based on the job id(Scheduled reports and quick reports) on the disk.
and it has become difficult for the end user as there were so many reports get generated per day ,needs to open each and every generated report to look for the report name.
Can we generate the reports based on the user defined names(or by the poller name).??
Thanks in the advance.
Regards,
Channa

Hi Lothar,
It will poll all the interfaces if you have selected the complete device while configuring the poller .
While configuring the Pollers use the Option called “Poll by User Selection >>  Select the instances on which you want to poll the devices” .
Poll by User Selection > will give you the option of selecting on those interface whihc you want to monitor against the Template (cpu , interface availblity etc)
I have attached the screen shot of the same:
http://www.cisco.com/c/en/us/td/docs/net_mgmt/ciscoworks_lan_management_solution/4-2/user/guide/lms_monitor/lms_mnt/mnt-perf.html#wp1542387
Thanks-
Afroz
***Ratings Encourages Contributors ****

Similar Messages

  • HUM Polling time

    Hi,
    we use HUM (in LMS 3.2) to monitor and report the availability of some routers (and 10 Mbit lines) of our customers. At the beginning of each month the customer gets a report via email. So far so good. Our service time to monitor this devices are from 8am to 8pm. My question is how can i create a poller that polls the devices exactly between this time interval.
    This is important for us because during the night, say between 2am an 4am the carrier has often maintenance work to do on our WAN Link. Thus the poller will trigger a alarm and the availability of the customer devices in the reports are below 100% even though the customer devices and 10Mbit Links where actually 100% reachable.
    Location A(HUM) --------WAN Link---------------Location B-----------10 Mbit-----Customer A
                                                                                  |-----------10 Mbit-----Customer B
    Thanks. Best regards,
    Christian

    Well, in client-side code you can cancel a statement if it is blocked or running a very long operation. For example, in Java you can call a cancel() method on the Statement object after it has begun executing a SQL query (has to be done by a separate thread, of course). It should cancel it almost immediately, but for some reason there is a 5 minute delay. A friend of mine at another company can run the same code on his company's Oracle database, and the cancel is completed quickly, consistently. While my code consistently has to wait around 5 minutes.
    There must be some setting to adjust this time, since we have knocked off just about ever other possible discrepency (driver/driver version, database/database version, java/JDBC/version)

  • Hum Job report errors

    Hello sir,
    We are using cisco works LMS 3.1 and Hum version 1 in our network.
    In common service Job information status, we getting error
    1019.2306 QUICK_INTERFACE_UTILIZATION_REPORT_JOB Failed
    1189.265 QUICK_INTERFACE_AVAILABILITY_REPORT_JOB Failed
    These errors are generated in Common Services form Hum and After clicking the Job ID ,no information is displayed .
    Please help to solve this Error.
    Thanks,
    kareem

    How can we re-initialize the UPM database (we have never done it)
    Their is UPMlog which is nearly 320kb and we are unable to delete it. When we shutdown the crmdmgtd service the log was automatically deleted and when again service started log reappears.
    we have not set any thresholds in HUM up till now, but even then should this show as 'Failed' (RED) in the CiscoWorks Page? This seems pretty strange that if there are no thresholds set/violations the report task would show as failed?

  • LMS 3.2.1 HUM and Tomcat

    Ever since upgrading to the SP1 for LMS.
    Tomcat have become very unreliable and shuts down when I access HUM reports for any period.
    Process= Tomcat
        State  = Administrator has shut down this server
        Pid    = 0
        RC     = 0
        Signo  = 0
        Start  = 7/8/2011 12:43:32 PM
        Stop   = 7/11/2011 2:15:14 PM
        Core   = Not applicable
        Info   = Not applicable
    I have to shut very thing down and restart
    Any ideas ?
    Thanks

    Hi,
    This is from last pdshow output where Tomcat is up and running :-
    Process= Tomcat
        State  = Program started - No mgt msgs received
        Pid    = 117688
        RC     = 0
        Signo  = 0
        Start  = 7/12/2011 9:32:14 AM
        Stop   = Not applicable
        Core   = Not applicable
        Info   = Application started by administrator request.
        Process= TomcatMonitor
        State  = Running normally
        Pid    = 109820
        RC     = 0
        Signo  = 0
        Start  = 7/12/2011 9:32:18 AM
        Stop   = Not applicable
        Core   = Not applicable
        Info   = Tomcat Server up
        Process= Apache
        State  = Program started - No mgt msgs received
        Pid    = 117984
        RC     = 0
        Signo  = 0
        Start  = 7/12/2011 9:32:53 AM
        Stop   = Not applicable
        Core   = Not applicable
        Info   = Application started by administrator request.
    Is it down again ?
    Thanks,
    Gaganjeet

  • Dynamic membership for the HUM Poller?

    Looking for a way for the HUM pollers to automatically poll a newly added device rather than having to explictly go through and update everything every time new devices come in to the DCR.
    If you point HUM at a dynamic group will that work?
    Or is there another way?
    (fingers crossed)

    This is not yet doable.  The ability to do this to some degree is coming in LMS 4.0 due out this summer.

  • HUM poller and ciscoworks 3.2

    Hello,
    I have upgraded Ciscoworks LMS from 3.1 to 3.2
    Since the upgrade,  there's something strange...
    if a device doesnt respond (device availability) i receive an alert via email (wich is normal)
    after 5 min i should receive another mail for another violation (device still not available)
    before the upgrade i had email alert every violation ( poller 5min) but now i receive only
    an email for the FIRST violation.
    I can see the others violations on the HUM page every 5 min, (the device still not available...)
    but i should receive email every 5 min (it was like that before upgrading....)
    Someone can help on this ?
    thanks

    There should only be one notification (when the problem first occurs).  If the problem continues to occur, no further notifications should go out until the initial problem clears.  Once the problem clears, and then occurs again, another notification should go out.

  • LMS 3.2.1 - Unreachable Device Report - ICMP problem

    Hello,
    I use the unreachable device report in CS for checking the basic reachability of the managed devices.
    A very useful feature!
    But on one LMS installation I have a huge number of "unreachable" devices which are normally reachable via ICMP.
    I use only the ICMP check with a timeout of 2 sec and one retry.
    Checking the debug for that polling told me that at the beginning of the daily running job all works fine.
    CS sends an ICMP to 10 devices and gets response. After that the next 10 devices and so on.
    After some cycles it increases the number of parallel workflows to 2, means 2x 10 devices will be polled.
    And with that change the problems begin, from my point of view. At this point 2 or 3 devices will be marked as unreachable.
    With the next cycle of 2x10 devices 5-8 devices are "unreachable" and then all devices till the end are unreachable.
    That sounds like there is an overflow on the application or server which can't handle so much ICMP replies.
    Changing the timeout or retries didn't help.
    Is there a possibility to fix the parallel requests to 10 without an increase?
    Thanks a lot!
    Sven

    This sounds like #
    CSCte60815    DCRDevice Poll using ICMP wrongly shows devices as Unreachable
    You may have to use snmp as well to get the correct status.

  • LMS 4.2 specific interface utilization report

          Hi,
    is there a way to create a interface utilization report only for a specific port? Like switch1->interface fa0/10
    Right now i can only choose all ports from a device?
    Thank you.
    Chris

    So, the new weekly report does not show the high Utilizations anymore, but there is a new problem:
    In the "Report Details", there are 7 devices and 126 interfaces, but in the "Interface Utilization Summary", there are only 49 Interfaces.
    I have added a screenshot, so that you can see, what I mean.

  • LMS 4.2.4 - Creating daily report for checking mac-adress list (IP hone) existing on the network

    Hi,
    we would like to  create a daily report for checking  (by user-tracking function) mac-address list on the network.
    I try to use “report designer” on “report” dashboard without any success. Could you help us to provide or create a method for applying a report job every day for checking our mac-address list
      Thanks in advance.

    you can do the following
    1. -create a quick report  {Reports > Inventory > User Tracking > Quick Report}
    2.export the last report which I suggested and filter the MAC address you are interested in
    3. you can create a Custom report  {Reports > Report Designer > User Tracking > Custom Reports } as per your need.
    Thanks-
    Afroz
    *** Ratings Encourages Contributors ****

  • Infotype 1002 (LMS Course Description): Is there any report?

    Hi Experts
    We want to print all description for our courses in a report. Is there any report in SAP which takes the description data from infotype 1002. I know the tables hrp1002 and hrt1002 as well as the view hrv1002a. But I can't find any report we can use for that.
    Does anyone have an idea?
    Thanks,

    Hi Dilek
    Thank you for your information. I was able to execute infotype 1002 from a course type. The problem now is that I can't see the real description from the subtypes like "Abstract", "Course Content" etc. It shows me only "With 7 Description" in the Description column.
    Do you know how I can see the real content?
    Thanks,
    aziz

  • Cisco Prime LMS 4.2 Device Availability Poller & Portlet

    The default, non-editable "System" Device Availability poller appears to be the only one used by the Availability Pie Chart Portlet. Or is there a way to a show a chart based on a user defined poller, which excludes devices known to be currently offline?

    Hi ,
    It's true  that you will not be able to Delete the system Defined pollers ,however you can DEACTIVATE them.
    selecet system defined device availblity poller and De-activate it..
    Now created a NEW poller , add the devices which you are interested in. and you should able to see the data in the PIE chart for the user defined poller.
    Thanks-
    Afroz
    [Do rate the useful post]

  • Interafce utilization report in lms 3.1

    Hi I have installed LMS 3.1 at ine of our customer. when we are extracting interface utilization report(HUM interface report) It gives me the graphs which are in format of packets/second or value in % . Customer want a simple report which will give him the graps in bite or Kb per second. even if when the operator will pull the report the report should be generated simplly port utilization for both RX and tx in Kb or Mb insted of octate/packets per second.
    Is it possible ? if it is possible please guide me how to configure the report template.

    Hi Joe,
    Can you clarify if this is correct
    ( Avg % Rx + Avg % TX ) x Total Bandwidth configured on interface/100 = Total Bandwidth Utilization 
    For eg:  Avg % Rx=11
                Avg % Tx=11
                Interface= Gigaethernet 1/1
                Bandwidth 465000
    Bandwidth= 465000= 46.5 Mbps
    Now Applying formula = (11+11) x 46.5/ 100 = 10.23 Mbps i.e actual interface utilization
    Regards
    Gautam

  • Captivate Quiz Not Reporting Correctly in LMS

    I am using Captivate 5.0 to publish a project to an EKP LMS. I am able to get the file to show complete in the LMS, but the quiz is not reporting correctly. Instead of a percentage it is reporting the number of points earned. Is there any way to have a percentage reported instead? I would appreciate any suggestions.  Grace

    Hi Grace,
    Can you check the Highlighted part and reset your Radio button to 'Percentage'--
    Thanks,
    Anjaneai

  • Cisco Works LMS HUM issue

    Hi,
    I am using Cisco works LMS 3.1 with HUM 1.1.0. I am receiving thresold and job schedule mail alert from HUM.
    It is showing error in JOB history  “Not able to connect the mail server” while alerts from RME,IPM,CS,DFM are coming on mail.
    I have Configured HUM just 3 days back and all others application had been configure 4 months back.
    Please help.
    Regards,
    DJ

    Hi Clarke,
    Thanks for response. Please see the attached HUM smtp error. I have tried the HUM JOB with sniffer to filter smtp port 25 traffic but nothing is reflecting
    in sniffer when trying to send mail through HUM while DFM,RME IPM mail are showing in sniffer and we are getting mail as well.
    I have upgraded HUM version from 1.1.0 to 1.1.2 but the error is same.
    Regards,
    Dinesh Joshi

  • Lms 4.0 - dbreader tool

    Hi Cisco Team,
    Recently i have come across hum reports value showing blanks...
    I wonder if my hum polling is falling back from snmpv2 to v1 due to an open bug CSCtx57337.
    Before i do the changes in umpproperties, would like to know how to use the dbreader tool to find out what are the devices affected by this...
    We will have to do some excercise in the below...need some help pls.
    http://lmsserver:1741/dbreader/dbreader.html
    regards
    Rajesh

    In my notes, gleaned from old forum posts:
    ani cwsiSA
    cmf cmfDBA
    dfmEpm itemEpmUser
    dfmInv itemInvUser
    dfmFh itemFhUser

Maybe you are looking for