Load cells and non contact strain measurement

I am designing a bi-axial machine which meant for a fatigue test.
Could someone recommend me where to get a dynamic load cells and as well non-contact strain measurement?
Thanks.

Hi Alvin788,
Do you presently use any hardware to measure these or are you enquiring as to what hardware/software you will need? Are you planning to use LabVIEW? The following three links talk about measuring Load Cells as well as Strain Gauges 
Continuous Acquisition from a Smart TEDS Load Cell Sensor
How do I Configure a Load Cell in MAX?
Strain Measurement with a Strain Gauge
This post will also be highly helpful.

Similar Messages

  • Infotype for  Employeeu2019s Work cell and Emergency contact phone?

    Hi All,
    I am currently working on HR ABAP.
    I   want to know the following fields information.
    Employeeu2019s Work cell and Emergency contact phone.
    in sap from where, we can get the Employeeu2019s Work cell  and Emergency contact phone??  In which infotype   , field and subtype?
    What about Emergency contact phone? Note that for Emergency contacts, there can be multiple records with current validity. You need to determine if you should show all of them, or only one. There is no way to know which one is the u201Cprimaryu201D contact.
    Regards,
    Kishan

    Kishan,
    This is not a ABAP related question. To give you some hint check IT 0006
    Thanks
    Bala Duvvuri

  • PASCO Load Cell and NI DAQ Interfacing

    Hi everyone,
    I have a PASCO Load Cell PS-2200 and I am trying to interface it with an NI-9201 AI (in conjunction with a NI-cDAQ 9172). Instead of attaching wires to the cell's pinout, I stripped a PS2 connector and rearranged the wires to match the pinout of the sensor (which are the strain gauge input, strain gauge output, the excitation voltage of 4.2 and the ground). I connected the strain gauge signal to a channel of the NI 9201 and I am using an external power source to provide voltage to the cell. My VI is trivial and consists of an input DAQ and Lowpass filter.
    The problem is that the input signal is obviously not right, it looks periodic for one. The filtered signal appears stable at first but slowly increases over time. And the signal does not respond to applied stresses.
    I would really appreciate any help on this. I am a ME sophomore and have little experience with LabVIEW.
    Thank you.

    Thank you Jignesh and Dave,
    Jignesh, I do not have a scope I can measure the ouput with. And no, the cell does not respond to variable loads. Also, please find attached the snapshots you had asked for. The front panel snapshot shows the cell's reponse when under no load
    Dave, the module I am using has a 16 bit resolution and within a +/- 10 full inut range, don't we have enough resolution to acquire the smallest change?
    Also, from the pinout of the load sensor, the pin for the excitation terminal and the positive strain gaugw output are adjacent. They are not the same terminal. We took every possible precaution to make sure that the terminals of the PS2 connector did not touch during soldering.
    Thank you for your help again.
    Attachments:
    block diagram.jpg ‏159 KB
    front panel.jpg ‏390 KB

  • Read from both load cell and accelerome​ter

    Hi,
    I'm trying to collect data from both load cell (which doesn't need excitation) and accelerometer (which needs 4 mA excitation). As you can see below, I wrote a simple program to collect data from both devices. However, my program provides 4 mA of excitation to all channels, one of which shouldn't receive any current. How can I selectively provide the excitation to specific channels?
    Any suggestions?
    Solved!
    Go to Solution.
    Attachments:
    readfromtwodevices.vi ‏47 KB

    Good morning jeongho20000,
    Both aeastat and falkpl have provided excellent solutions for this.  I also wanted to mention a good KnowledgeBase article found at ni.com by searching for "daqmx channel same task" in the internal search bar.  This helps to outline both solutions.  After searching, you can then select multiple entries, but the best that I found was the 3rd choice, titled: Using Different Types of DAQmx Global Channels in the Same Task. 
    You can download from the article the attached example VI titled Multiple Channels Created.vi, and modify the block diagram to fit your needs.  Wiring the Task Out to the Task In of two DAQmxCreateChannel VIs is the programmatic equivalent of adding multiple Global Virtual Channels created in Measurement and Automation Explorer (MAX) to a common Task in MAX.  Either method works, it is only a user preference.  Feel free to reply if you need further clarification/explanation. 
    Best,
    Message Edited by cyclone2k9 on 04-06-2010 11:08 AM
    Message Edited by cyclone2k9 on 04-06-2010 11:09 AM
    Adam
    Academic Product Manager
    National Intruments

  • Blocking and reporting contacts and non-contacts

    Since switching to skype from MSN messenger i have only really had problems. 
    I have edited my settings so that I have privacy sorted and only my contacts can message me, but i am STILL having messages from a non-contact and have done since the 11th march. I cannot block them because they are not a contact and I cannot report them because they have not added me as a friend. 
    I am constantly barraged by this person and not in the best of tastes. Sort it out Skype! This is not acceptible!! 

    can nobody give me any ideas here? Come on you have someone using your service to make bomb threats...You are the only ones who can pull his information and report him properly.

  • Firefox will not load pages, and none of the steps in the support section are helping. I need a real person to help. Resetting, Reloading, Proxy, Firewall...

    I have gone through all of the above support articles after receiving the following message "Unable to connect
    Firefox can't establish a connection to the server at www.msn.com.
    The site could be temporarily unavailable or too busy. Try again in a few moments.
    If you are unable to load any pages, check your computer's network connection.
    If your computer or network is protected by a firewall or proxy, make sure that Firefox is permitted to access the Web."
    I reset, I checked the proxy (no), I checked the firewall (enabled for FF), I uninstalled/reinstalled, I have run malware check (negative). I am at my wit's end because I NEED FF for work applications that will not come through IE due to corporate policy. I need serious help or I am screwed.
    FF was working perfectly until a week ago. Now it starts up on the FF home page but goes no further, even in SAFE mode. What gives?
    I uninstalled Chrome, even.

    hello, normally such issues are caused by a firewall/security software which doesn't recognize & therefore blocks new firefox versions. please try to remove all program rules for firefox in your firewall and let it detect the program again: [[Fix problems connecting to websites after updating Firefox]]

  • I have to iphones with the same apple id so when we loaded icloud and deleted contacts of one it deleted of both is any way to get those contacts back

    how do i get deleted contacts back ? I just added icloud to two phones with the same apple id

    You may have to restore to your latest sync. That's my only solution to your problem. If this didn't help, then I suggest you to visit the closest Apple store and get Genius for help.

  • Absolute Accuracy of a Load Cell measurement.

    I see how to calculate absolute accuracy for the SCXI-1520 and SCXI-1600 combination.  To call out the accuracy of a load cell measurement, do I have to add the load cell specification numbers for non-linearity, non-repeatability, and hysteresis to the absolute accuracy calculations?

    Hi KPR,
    If you want the entire system accuracy, including the load
    cell, we definitely need to include the load cell accuracy in our calculations.
    I am not sure which document you were looking at to get the accuracy thus far,
    but KB 2X4HGEBG
    gives a great explanation about accuracies. In order to include the load cell accuracy, first
    get the absolute accuracy of the load cell, and then put this in the equation ‘System
    Accuracy = ( (Absolute Accuracy 1)^2 + (Absolute Accuracy 2)^2 + (Absolute
    Accuracy 3)^2 + ...) )^(1/2)’ as ‘Absolute
    Accuracy 4’.
    David L.
    Systems Engineering
    National Instruments

  • Question on Measuring Lift Force for MAV Ornithopter for Student Project using Load Cell

    Hey everyone!
    I am new to these forums so bare with me, please. I am part of a senior design student group working on making a micro aerial vehicle ornithopter (generates lift by flapping its wings) similar to this Design.
    We are using this load cell connected to an AD620 Op-Amp circuit that basically has two input wires from the load cell coming into the op-amp with a gain of 100 (there is an Rg resistor with 500 ohms in the circuit). The load cell and op-amp circuit are both powered correctly with 10 V and +-15 V, respectively. There are two output wires coming out of the circuit. One comes out of the 6th terminal of the op-amp, and one is connected to ground. If we turn on everything and test the output of the circuit with a multimeter there is little if no fluctuation in the output voltage, which is about .25 V with zero load. If we add precise weights and form a linear graph of the output voltage vs. weight, we can find that there is about .0045 volts/gram relationship.
    Here comes the part we we are having trouble. It seems as though the circuit it working correctly, but when we try and hook it up to our USB-6221 DAQ Board though the ai0 (or any analog input) and confirm a LabVIEW program to read the output, we get a ton of noise along with a weird looking graph.
    Here is a picture of the front panel that shows the output we are getting http://img130.imageshack.us/i/frontpanelg.jpg/
    Basically, I would have though we could get a straight line that continuely increases or decreases depending on the load on the load cell. Why would it graph a ton of vertical lines? I would think it would be just one data point per time value?
    Here is the simpler block diagram just to test the output: http://img26.imageshack.us/i/blockdiagramsmall.jpg/
    Here is the main block diagram that we were going to use to convert to force, etc. but its not working (no need for while loop?): http://img15.imageshack.us/i/blockdiagrambig.jpg/
    The properties of the DAQ Assistant VI is as follows:
    input range: -10 to 10 v
    RSE terminal configuration
    acquisition mode: n samples and not sure how many samples we want to read or how fast. we had 1k hz and 100 samples and the image above is basically what we got it the program runs continuously. 
    I don't know what else I can tell you, except that if anyone helps me you would be like a godsend to our group. It would be very much appreciated
    Thanks!!!

    As I am unable to look at youor images (the corporate filter here is blocking the url) I can't see what you are describing. I will say that a multimeter will not show fast transitions that will show up in a LabVIEW/DAQ application, so using a meter usually doesn't tell you that much about signal "cleanness". How long are the wires from the op amp/load cell to the DAQ? How long are the wires, and what type (shielded, twisted pairs, untwisted pairs, etc.) from the load cell to the op amp. The output levels of the load cell are usually quite low, so the possibility of also picking up "environmental" electrical noise is very high, and this will be amplified as well. Since the output of the op amp is higher, the noise introduced between it and the input to the DAQ is less of an issue, but there as well. So making sure that signal wires are properly shielded and grounded is important, and there are long papers describing this for low level analog signals. Since the load cells desired output will probably vary relatively slowly (a few Hz) it may also be helpful to put a simple low pass filter before the DAQ.
    You should insert the images into your post, as jpg, or png (you have jpg images) Not bmp! (this is for others that might read your post, yours are jpg which should be ok). Generally most of us won't or can't go to links, corporate network filters and corporate policies frown on it, too much maleware lurking at the end of unknown URL's
    Putnam
    Certified LabVIEW Developer
    Senior Test Engineer
    Currently using LV 6.1-LabVIEW 2012, RT8.5
    LabVIEW Champion

  • VI to measure Load Cell

    Hello everyone,
    So I'm extremely new at this and really need some help.  I need to create a VI that is going to be able to read the force using a load cell.
    if anyone can help me I am willing to pay for your time, I don't have much time to learn on my own so I need the help of someone.
    I have a power supply load cell and DAQ
    please email me if your willing to help me and make some money
    Power Supply: http://www.testequipmentdepot.com/bk-precision/power-supplies/1786a.htm?gclid=COahppSjtbUCFQuqnQodmF...
    Load cell: http://www.omegadyne.com/ppt/prod.html?ref=LC401&flag=1
    DAQ: NI USB-6008
    [email protected]

    Hi,
    If you need to acquire voltage from your load cell with a USB-6008, you can run the attached VI.
    Regards,
    Attachments:
    Voltage.vi ‏34 KB

  • 6-Chan Load Cell Conditioning- Which NI Products?

    We are building a machine with 6 strain gage based load cells. We need simple signal conditioning, including power supply, between the 6 load cells and our data acquisition system. What are the NI products we need to buy?

    Sure. For simple signal conditioning, go to www.omega.com (Omega Engineering)and take a look at the following Bridge Conditioning Modules:
    DMD-460 Series
    BCM-1 Series
    OM2 Series
    All of these devices provide some/all of the capability you require. Omega Engineering has an extensive line of products to support accurate, economical, and easy pressure, force, and strain measurement. (No I do not work for Omega Engineering; however, I have used their products over the last 20 years and have always been satisfied with the results). Omega will also send a complete reference set of their current catalog in "paper form"(about 70 lbs) upon request. These catalogs have technical instructions and application notes that rival those found at NI

  • "connecting a load cell to scb-100"

    I have an scb-100 and want to know if it is possible to connect a load cell to it and if so, how.

    It is probably possible, but you have to have some additional circuitry in order to use the load cell. Typically, load cells are comprised of strain gauges which require some kind of Wheatstone bridge completion. Additionally, most strain gauges need excitation. If you can provide the bridge completion and excitation, then you could simply read the output of the strain gauge by connecting the output + and - to your SCB-100. However, setting up this external circuitry can be a little complicated. So, the recommended setup is to use some signal conditioning. National Instruments provides a couple of options regarding signal conditioning for load cells. Below is a link to a tutorial that discusses how to measure a load cell and what hardware is recommended for
    that. I hope this information helps.
    Tutorial

  • Data acquisition from a 250N Load cell

    Hi ,
    I am very new at using the Labview.I am using Labview 6i(PCI 6052E).The load cell(250N) is connected to a pump.The pump has 2 bags.One of them is filled with water and the other is empty.I want to load the bag which is empty from the bag filled with water using the pump.The load cell is connected to the bag which is filled with water.I am trying to aquire a volatge signal continously from a load cell and display it on a chart.
    My program has no errors and I am able to run the progam.But it is not aquiring any signal.Could u please help me out.Attached is my code for the same .
    -Manasa

    Hi Manasa,
    Make sure you are handling your errors in your code. You can do this by wiring your error clusters through your VI and then terminate them in a General Error Handler VI. If you are doing this, make sure that your device works in Measurement & Automation Explorer (MAX). Do this by opening a test panel and verifying that you can get a known voltage (like a battery) to read correctly. If you can successfully get a voltage in MAX, try running one of the example programs. You can find them at Help » Find Examples..., then browse to hardware input and output. If you can get an example program that is similar to what you are trying to do to work, try comparing your code to the example.
    Please post back if you have any questions. Have a great weekend!
    Ryan D.
    District Sales Manager for Boston & Northern New England
    National Instruments

  • Connection for load cell to NI9237

    Hi,
    I have this omega load cell part LCKD-10 which is a half bridge load cell that I need to connect to the NI9237. Please advice on the connection.
    Thanks
    Joelle

    Thanks. I need to write out a program which checks the centrality of force. I will be using 5nos of the omega load cell, 1 in the centre(Isolated) and the other 4 at all 4 corners. I'm suppose to firstly calibrate the load cell and then take measurement of the force applied to the 5 load cell and display the result in a form of a radar graph (Just a dot in the centre of the graph to show the centrality of the force). Appreciate if you can provide some procedures or program that I can use or try out.

  • Shaker control with output from load cell

    Hi
    I am using a (analog output) shaker to generate sinusoidal forces at different frequency and of different magnitude. I am also using a load cell (analog input) to sense these forces . The max force generated by shaker decreases as I increase the frequency of vibration. Whereas, the experiment requires the force to be constant when the frequency is changing. I plan to use the max force obtained from the load cell data, as the process parameter, to modify the amplitude of input wave which excites the shaker. I seek help in this regard. I am using PCI6221 and SCC68.
    Thanks in advance.
    RSD 

    Sorry, I have been extremely busy the last couple of days (months?). I still haven't had much time to ponder the problem, but one thought comes to mind, at what frequencies are you running this and what is the load cell, and its supporting electronics, frequency response. You mention that the amplitude decreases as the frequency increases, but that you increase the gain of the driver amplifier. It (the system) is most likely non-linear in its response, so how much you increase the gain will vary. The nonlinearity of the response is one of the reasons there is so much published about control systems, PID controllers, etc.
    Putnam
    Certified LabVIEW Developer
    Senior Test Engineer
    Currently using LV 6.1-LabVIEW 2012, RT8.5
    LabVIEW Champion

Maybe you are looking for