Connection for load cell to NI9237

Hi,
I have this omega load cell part LCKD-10 which is a half bridge load cell that I need to connect to the NI9237. Please advice on the connection.
Thanks
Joelle

Thanks. I need to write out a program which checks the centrality of force. I will be using 5nos of the omega load cell, 1 in the centre(Isolated) and the other 4 at all 4 corners. I'm suppose to firstly calibrate the load cell and then take measurement of the force applied to the 5 load cell and display the result in a form of a radar graph (Just a dot in the centre of the graph to show the centrality of the force). Appreciate if you can provide some procedures or program that I can use or try out.

Similar Messages

  • "connecting a load cell to scb-100"

    I have an scb-100 and want to know if it is possible to connect a load cell to it and if so, how.

    It is probably possible, but you have to have some additional circuitry in order to use the load cell. Typically, load cells are comprised of strain gauges which require some kind of Wheatstone bridge completion. Additionally, most strain gauges need excitation. If you can provide the bridge completion and excitation, then you could simply read the output of the strain gauge by connecting the output + and - to your SCB-100. However, setting up this external circuitry can be a little complicated. So, the recommended setup is to use some signal conditioning. National Instruments provides a couple of options regarding signal conditioning for load cells. Below is a link to a tutorial that discusses how to measure a load cell and what hardware is recommended for
    that. I hope this information helps.
    Tutorial

  • Custom scale for load cell

    Hi
    I am using a load cell to monitor an impact force. The load cell has a fixture attached to it which results in a non zero output. I am using a custom scale to convert the output from the load cell in volts to force to Newtons.
    I am creating a custom scale and applying it to the task. I then want to be able to programmitically tare (zero) the load cell output before testing. However, my code does not work. There are no errors, but the gradient and intercept controls within the while loop do not function. Can anyone tell me why? I am aware that this could be done mathematically but I do not understand why the property node method does not work.
    I am using labview 2010 with the latest version of daqmx (9.17 I think). My hardware is the USB-6211 card.
    Many thanks.
    John
    Attachments:
    custom_scale.png ‏53 KB

    Hi John,
    Thank you for a good description of the problem you are facing, as I understand it you have set up a custom scale but it doesn't seem to be functioning as you expected.
    I have looked into this for you and have found a few examples which may help with the development of your application, I have also linked some articles for you.
    The custom scale will need to be created entirely before the task is created, so any modifications can only be done before acquisition begins.
    I hope this information is useful, and if you have any further queries please go ahead and post them and I will look into it for you.
    Thanks
    Stephanie L
    Applications Engineer
    National Instruments UK and Ireland

  • Need for sugestion about DAQ Card for load cell

    Hi.
    I have a AT-MIO-16XE-50 DAQ card. But, I guess it doesn't work with load cell since it dosen't have output. So I need your regomendation about what DAQ card I should use. Also, if I need to use strain gage conditioner, recomende to me.
    Thanks
    Jee

    I couldn't find any information about a DAQ 512, but I did find info about a DAQCard-512 and DAQCard-500. If you meant one of these boards, then you will need NI-DAQ 6.9.3. That is the latest version of NI-DAQ to support these boards. Post again if you need additional assistance.

  • Configuring RFC connections for load balancing.

    Hi ,
    We have the following landscape for our systems.
    The database is installed on z/os , db2 (mainframe). The central services( SCS and ASCS) are also on the mainframe. So the message server is on mainframe.
    The CI is on AIX and The DI is on AIX.
    We have Logon groups configured and load balancing Configured and is RFC enabled.
    1) When we connect to SAP using the SAPGUI and  the portal connection is made to either CI or DI depending upon the best response times.  Now recently we are running the mercury load testing, all the users are connecting to DI. Why are the users connecting to DI even though we have load balancing?
    2) I have a system with SID BP0, with one CI and one DI. The logon group is BP0 and the message server name is cyrix. Now I have other another system EP0. I have created a RFC connection from EP0 to BP0. In SM59 I have selected the load balancing option, and provide the message server name, SID and logon group name. The connection does not work. If I connect directly to the CI or DI the connection works. Please tell me how can I configure load balancing for RFC connections.
    Thanks
    Manmath.

    Dear 917996,
    There are two types of load balancing:
    - Client-side load balancing (setting up the tnsnames.ora on client side). More information here (http://ggsig.blogspot.co.uk/2012/04/client-side-
    load-balancing-in-oracle.html). Very good video produced my friend Igor Melnikov is here (http://www.dsvolk.ru/oracle/racdd4d/demos/video/loadbalance/client/clientloadbalance_viewlet_swf.html)
    -Server-side load balancing (remote_listener and setting service parameter clb_goal). Very good Igor Melnikov's video is here (http://www.dsvolk.ru/oracle/racdd4d/demos/video/loadbalance/server/serverloadbalance_viewlet_swf.html).
    I have read about client side and server side load balancing. By editing tnsnames.ora I have enabled client side load balancing which is suppose to select listeners at random. then why does it only go to second node?Could you please show your tnsnames.ora on client?
    Please can anyone help me to configure server side load balancing with SCAN. I have read many many post but couldn't find a clear answer.Based on your output (remote_listener string cmbtrnrac-scan:1521) you have already configured the server side load balancing.
    SQL> show parameter listener
    NAME TYPE VALUE
    listener_networks string
    local_listener string (DESCRIPTION=(ADDRESS_LIST=(AD
    DRESS=(PROTOCOL=TCP)(HOST=10.1
    7.67.214)(PORT=1521))))
    remote_listener string cmbtrnrac-scan:1521How many SCANs do you use? Do you use DNS?
    regards,
    Gennady

  • Applying dynamic routing feature on outdoor wireless connection for load ba

    Gentlemen,
    Does the Cisco outdoor wireless unit support dynamic routing (e.g. RIP or others) to do the load balancing between leased line and wireless connection.
    I am looking to confirm if the outdoor unit has the routing features to apply this scenario.
    Thank you,

    No Response !!!!
    Pls your action.
    Thank you,

  • DAC voltage capped when operating in torque mode with load cell feedback

    Hi, i'm doing a tension control on a cable driven system using servo motor. I had connected a load cell as analogue feedback for cable tension into the labview programme suggested in http://www.ni.com/pdf/manuals/371242c.pdf (Figure 13-3. Torque Control Using Analog Feedback Using LabVIEW)
    Problem 1: The response between desired tension and actual tension is good until about 80N, when the motor stops responding to higher torque changes. The voltage output in DAC is only 4-5V (max voltage output is suppose to be 10V) and the motor and amplifier had been verified to run up to 200N. What is limiting my DAC?
    Settings:
    Card: PCI-7350
    Analogue input: 0-5V
    Problem 2: I had implemented a low pass filter of 30Hz in MAX for the load cells. The effect is quite good for the low tension. However, as the tension increases, the noise increases proportionally too, causing vibrations and switching sounds to be heard at higher tension. Is there anyway to overcome this?
    Please help. Thanks 

    I can't see anything special with your settings, so I currently don't have a clear understanding, why the output voltage is limited.
    Could you please test the analog output? You could do this configuring the axis as an open loop stepper axis. This will allow you to set the analog output with Load DAC.
    Does this allow you to output higher voltages?
    Could you please do the test with and without signal connection to the analog output? Maybe the input impedance of your drive is too low and pulls down the board's output voltage.
    I hope that helps,
    Jochen

  • Data acquisition from switching 500lbs load cell to 100lbs load cell

    I am using 500lbs load cell, and acquiring data by inputing 2volts from 2345 signal conditioning board, and sensor output is connected to SCC-AI03 pin 3 and 4 , and configure this load cell to a channel using NI MAX, data neighborhood, traditional NI-DAQ virtual channel, the physical quantity is voltage set at range -10 to 10, and sensor also set at voltage with no scaling, but, I couldn't get any signal when 100lbs load cell is use, the difference of this 100 lbs load cell is the rated output is at 2.958mV/V, while the 500lbs rated at 1.8295mV/V , how should I do this?
    Thanks.

    Hi,
    At this point, it is difficult to determine exactly what is happening to your acquisition. Could you please provide some additional information by answering the following questions:
    What voltage are you reading with the 500 lb load cell?
    Would it be possible to connect your load cells to a DMM and see what voltage reading you receive? If so, what do you see?
    What is specifically happening when you connect the 100 lb load cell?
    I also noticed that you are using the Traditional NI-DAQ (Legacy) driver. I recommend upgrading to the NI-DAQmx driver.  Here are a couple of links with more information about DAQmx:
    Advantages of NI-DAQmx:
    Transition from Traditional NI-DAQ to NI-DAQmx:
    Learn 10 Functions in NI-DAQmx and Solve 80% of Data Acquisition Applications:
    Regards,
    Hal L.

  • Configurin​g Load Cell [ NEW ] Feild Point

    Hi, I'm trying to set up some Data acquisition from a load cell through my FeildPoint AI-110. The Load Cell I have is rated to 500KG and has a Out put of 2.997 mV/V. I can connect the load cell to field point and display the voltage difference in Max, but I’m struggling to use this to get any kind of scaled reading to using in Labview.
    Can any one help.
    Many thanks

    I think the attached should get you pretty close.  The top section uses just the constants you posted and
    assumes a constant excitation voltage of 12.25.  The bottom section uses the actual, current excitation
    voltage when the measurement is made.  I think this second approach will probably give you better long
    term results.
    The bridge voltage is the voltage displayed in MAX.
    Matt
    Message Edited by Matthew Williams on 07-04-2007 08:48 AM
    Attachments:
    strain_example.vi ‏34 KB

  • Question on Measuring Lift Force for MAV Ornithopter for Student Project using Load Cell

    Hey everyone!
    I am new to these forums so bare with me, please. I am part of a senior design student group working on making a micro aerial vehicle ornithopter (generates lift by flapping its wings) similar to this Design.
    We are using this load cell connected to an AD620 Op-Amp circuit that basically has two input wires from the load cell coming into the op-amp with a gain of 100 (there is an Rg resistor with 500 ohms in the circuit). The load cell and op-amp circuit are both powered correctly with 10 V and +-15 V, respectively. There are two output wires coming out of the circuit. One comes out of the 6th terminal of the op-amp, and one is connected to ground. If we turn on everything and test the output of the circuit with a multimeter there is little if no fluctuation in the output voltage, which is about .25 V with zero load. If we add precise weights and form a linear graph of the output voltage vs. weight, we can find that there is about .0045 volts/gram relationship.
    Here comes the part we we are having trouble. It seems as though the circuit it working correctly, but when we try and hook it up to our USB-6221 DAQ Board though the ai0 (or any analog input) and confirm a LabVIEW program to read the output, we get a ton of noise along with a weird looking graph.
    Here is a picture of the front panel that shows the output we are getting http://img130.imageshack.us/i/frontpanelg.jpg/
    Basically, I would have though we could get a straight line that continuely increases or decreases depending on the load on the load cell. Why would it graph a ton of vertical lines? I would think it would be just one data point per time value?
    Here is the simpler block diagram just to test the output: http://img26.imageshack.us/i/blockdiagramsmall.jpg/
    Here is the main block diagram that we were going to use to convert to force, etc. but its not working (no need for while loop?): http://img15.imageshack.us/i/blockdiagrambig.jpg/
    The properties of the DAQ Assistant VI is as follows:
    input range: -10 to 10 v
    RSE terminal configuration
    acquisition mode: n samples and not sure how many samples we want to read or how fast. we had 1k hz and 100 samples and the image above is basically what we got it the program runs continuously. 
    I don't know what else I can tell you, except that if anyone helps me you would be like a godsend to our group. It would be very much appreciated
    Thanks!!!

    As I am unable to look at youor images (the corporate filter here is blocking the url) I can't see what you are describing. I will say that a multimeter will not show fast transitions that will show up in a LabVIEW/DAQ application, so using a meter usually doesn't tell you that much about signal "cleanness". How long are the wires from the op amp/load cell to the DAQ? How long are the wires, and what type (shielded, twisted pairs, untwisted pairs, etc.) from the load cell to the op amp. The output levels of the load cell are usually quite low, so the possibility of also picking up "environmental" electrical noise is very high, and this will be amplified as well. Since the output of the op amp is higher, the noise introduced between it and the input to the DAQ is less of an issue, but there as well. So making sure that signal wires are properly shielded and grounded is important, and there are long papers describing this for low level analog signals. Since the load cells desired output will probably vary relatively slowly (a few Hz) it may also be helpful to put a simple low pass filter before the DAQ.
    You should insert the images into your post, as jpg, or png (you have jpg images) Not bmp! (this is for others that might read your post, yours are jpg which should be ok). Generally most of us won't or can't go to links, corporate network filters and corporate policies frown on it, too much maleware lurking at the end of unknown URL's
    Putnam
    Certified LabVIEW Developer
    Senior Test Engineer
    Currently using LV 6.1-LabVIEW 2012, RT8.5
    LabVIEW Champion

  • Is it possible to condition a load cell signal with a 1520 SCXI and then use it as the primary analog feedback for a 735X motion control board?

    My system
    PXI 1052 chassis
    PXI 8196 RT controller
    Flexmotion 7356 motion controller
    Flexmotion 7354 motion controller
    6259 M series DAQ
    1520 SCXI
    1520 SCXI
    1314 SCXI frount mounting terminal block
    DSM strain gage load cells
    Exlar SR Brushless PM motors
    Kollmorgen servo star CD series 5 drives
    My objective:
    I want to measure the force on the load cells with the 1520 SCXI (i.e. excite the load cell then amplify and condition its output) then I want to use this analog (force) signal as the primary feedback for my motion control system (7356 and 7354 motion controller connected to my drives and motors).
    The problem:
    The motion controller boards (7356 and 7354) can be configured for force feedback control via analog feedback from a load cell.  However the boards implicitly expect the load cell signal to be amplified and conditioned with and external signal conditioner rather then using an NI SCXI module.  Currently I’m am reading the SCXI signals via the 6259 M seriers DAQ and consequentially have no way to route the signal into the 735X boards for force feedback control.  I can use softmotion to control the motors but then I loose the fast PID update rates possible with the 735X boards.
    The question:
    Is it possible to condition a load cell signal with a 1520 SCXI and then use it as the primary analog feedback for a 735X motion control board? 
    Thanks
    Patrick Aubin
    Ph.D Candidate
    University of Washington &
    VA MedicalCenter of Excellence for
    Limb Loss Prevention and Prosthetic Engineering  

    Hi GG,
    Thank you for your feedback.
    >create your own external circuitry to amplify the signal.>
    True a few op-amps could amplify and filter the signal externally but the performance of such an amateur built system will never match the accuracy and functionality of the 1520 SCXI.  That’s why we spent the $2500 for the professional version.
    >One thing that you could do is to use a UMI with your motion controller and then wire your signal from your SCXI to the UMI.>
    As I understand it the UMI is basically a break out connectivity interface for third party drives.  After conditioning and amplifying the analog force signal with the SCXI module the analog signal isn’t available to wire into a UMI.  To my knowledge the conditioned signal of the SCXI resides only in the PXI backplane (i.e. there is no physical access to the conditioned analog signal).  Can you explain how the UMI could be help here.
    Again thanks for your input GG.
    Patrick

  • Problem Load Balancing connections for Grid Control Console on port 80!

    I have two OMS and I'm balancing connections for Grid Control Console using a Software Load Balancer according with "Oracle Enterprise Manager Advanced Configuration". I have success where the load balancer is listening on port different to 80. When I configure Load Balancer to listen on port 80(architecture requirement) and distribute load between the two OMS(Port 7779), when login to Enterprise Manager Console the URL on the web browser changes to the port configured for HTTP server (port 7780) wich produces an "unable to connect" error message; and this behaviour also happends in some of the internal links of Grid Control Console too. Any ideas?
    Thanks in advance!
    Message was edited by:
    user463224

    I got it working, changing the "Port" directive to 80 on httpd.conf on HTTP Server

  • Trying to pair my new Iphone4 with my GE21518 Bluetooth Home Gateway         es it and connects for 1/2 second and then switches to not connected.  Also pairing with a Motorola 505 car unit and that seems OK.  GE unit allows me to have cell be home phone.

    I use my cell as my home phone and the GE Gateway worked fine with my old LG flip phone.   I have been unable to get the IPhone 4 to connect.
    It sees the GE21518 and connects for 1/2 second but then goes to not connected.  I have a Motorolla T505 in the car as a hands free Bluetooth and that seems to be working OK.  Anyone have experience with the GE Gateway or other suggestions.  Thanks! 

    I use my cell as my home phone and the GE Gateway worked fine with my old LG flip phone.   I have been unable to get the IPhone 4 to connect.
    It sees the GE21518 and connects for 1/2 second but then goes to not connected.  I have a Motorolla T505 in the car as a hands free Bluetooth and that seems to be working OK.  Anyone have experience with the GE Gateway or other suggestions.  Thanks! 

  • Does National Instruments produce a DAQ equivalent of an electronic load for fuel cell testing?

    I am trying to consider my options before purchasing an electronic load. I would like to use LabView software to record and analyze my data that I will be generating during fuel cell testing. I was just wondering if National Instruments produced an instrument similar to an electronic load or a couple instruments that could work in combination similarly to an electronic load. I have looked through the available DAQ instruments on the NI website and it seems that they all output signals too low for my application. The fuel cell I will be using outputs voltage from 0-2VDC and current from 0-4A. I understand the internal workings of an electronic load and realize that the best option would be to implement some sort of variable resistor to act as the load in my circuit, then use DAQ instruments to measure current and voltage respectively. The problem is that the range of my current, especially, is much larger than any allowable input range for any NI DAQ instruments.
    Any input would be much appreciated. Also if you have developed a testing system for fuel cells or other low power DC sources, please share any knowledge and information about how you went about designing your system.
    Thanks

    TravisW wrote:
    I am trying to consider my options before purchasing an electronic load....
    Any input would be much appreciated. Also if you have developed a testing system for fuel cells or other low power DC sources, please share any knowledge and information about how you went about designing your system.
    Thanks
    We used a DC Programmable Electronic Load from AMREL.
    WE used GPIB to talk to each of them The loads ley us set constant current/voltage and let us query the current values etc.
    Worked fine for us,
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • Do you need a cell connection for AP to work?

    Do you need a cell connection for AP to work?

    Hi ..
    Cellular or Wi-Fi either one.
    It is considered, "wallet free" >  Apple - Apple Pay

Maybe you are looking for

  • Adobe InDesign CS5 Has Stopped Working (installation issue)

    Please allow me to preface this by saying that this situation is RESOLVED, but I wish to share what happened to me with others for information purposes as I couldn't find anything regarding this issue online last night (mind, I was quite exhausted so

  • WebGL not working

    I recently noticed that WebGL no longer works for me in Firefox, even though it has worked in the past. I'm currently running Firefox 14.0a1 Nightly on Window 7 64-bit (although I have also tried it in FF11). When I opened, up about:support, it said

  • Cursor-pasing multiple values as a cursor parameter

    declare credit_amount number:=0; debit_amount number:=0; v1 number:=0; v2 number:=0; v3 varchar2(500); v4 varchar2(500); v5 varchar2(240); v6 varchar2(240); v7 number; v8 varchar2(240); v9 varchar2(240); v10 number; v11 number; v12 varchar2(240); v13

  • Regd certification. which one to go for ? :-(

    hello everyone, i really confused with the certification courses. which one should i opt for. teched is on oct 5-7 in bangalore. i have four options here -> 1.EP (totally new for me) 2.XI (totally new for me) 3.WAS (totally new for me) 4.ABAP (have w

  • What makes an audio file ineligible for Match

    What determines what is suitable for Match?  I have a series of lectures that I have loaded onto iTunes but they are not eligible for uploading why?