Log data

When a user that doesn't exist for OLAP Server is trying to login, the log writes that the user tried to login and failed because it didn't exist.But when an existing user tries to login and writes incorrectly the password, OLAP Server log only says that the password was incorrect but the user who did this doesn't appear.And the Log never writes the Ip address.Can I change the log level ?Any sugestions ?Thanks in advance

Depends on the version. Log info has been enhanced in v6.5.I'm on v6.5.1,If a user does not exist, I get this message in the log:User test does not existIf a user exists, but has an incorrect password, then this appears in the log:Incorrect password for login [testuser]

Similar Messages

  • SAP Business Workplace - No log data exists message

    Hi,
    We have the work items of EDI 810 configured to reach the workflow inbox of certain users.  The users have 300+ items in their workflow inbox - but when they click the Workflow Inbox they get a message - "No log data exists".
    The message is an error type: Message BL 223
    The message is coming from the function module BAL_CNTL_REFRESH.
    We tried to get the same workflow positions assigned to our user id and the unprocessed 300 + items came to our inbox and we are able to view and process the work items without any issue.
    The issue pertains only to the two users. It seems like it has something to do with the filter / layout settings set for the two users alone.  Could you please advice.
    Regards,
    Prabaharan

    Hi
    i am using SAP GUI at client place via Citrix.
    it was working fine till yesterday
    pls suggest. wat could be other possible reason
    thanks

  • RRMX - No log data exists

    Hi experts
    when i am entering RRMX tcode. i am getting error message at status bar as " No log data exists"
    Please help me out. What could be reson and how can i reslove it
    thanks
    pavan

    Hi
    i am using SAP GUI at client place via Citrix.
    it was working fine till yesterday
    pls suggest. wat could be other possible reason
    thanks

  • Change Log Data from DSO to CUBE

    Hi Experts,
      Is it possible to load/transfer change log data as well from DSO to Cube
    Thanks

    Hi,
    Yes it is possible.
    Create a DTP from DSO to cube.
    In the extraction tab of DTP choose the option
    Datasource Change log
    Hope it Helps!!
    Reward if useful
    Manish

  • DSC 8.6.1 wrong timestamps for logged data with Intel dual core

    Problem Description :
    Our LV/DCS 8.6.1 application uses shared variables to log data to Citadel. It is running on many similar computers at many companies just fine, but on one particular Intel Dual Core computer, the data in the Citadel db has strange shifting timestamps. Changing bios to startup using single cpu fixes the problem. Could possibly set only certain NI process(es) to single-cpu instead (but which?). The old DSCEngine.exe in LV/DSC 7 had to be run single-cpu... hadn't these kind of issues been fixed by LV 8.6.1 yet?? What about LV 2009, anybody know?? Or is it a problem in the OS or hardware, below the NI line??
    This seems similar to an old issue with time synch server problems for AMD processors (Knowledge Base Document ID 4BFBEIQA):
    http://digital.ni.com/public.nsf/allkb/1EFFBED34FFE66C2862573D30073C329 
    Computer info:
    - Dell desktop
    - Win XP Pro sp3
    - 2 G RAM
    - 1.58 GHz Core 2 Duo
    - LV/DSC 8.6.1 (Pro dev)
    - DAQmx, standard instrument control device drivers, serial i/o
    (Nothing else installed; OS and LV/DSC were re-installed to try to fix the problem, no luck)
    Details: 
    A test logged data at 1 Hz, with these results: for 10-30 seconds or so, the timestamps were correct. Then, the timestamps were compressed/shifted, with multiple points each second. At perfectly regular 1-minute intervals, the timestamps would be correct again. This pattern repeats, and when the data is graphed, it looks like regular 1-sec interval points, then more dense points, then no points until the next minute (not ON the minute, e.g.12:35:00, but after a minute, e.g.12:35:24, 12:36:24, 12:37:24...). Occasionally (but rarely), restarting the PC would produce accurate timestamps for several minutes running, but then the pattern would reappear in the middle of logging, no changes made. 
    Test info: 
    - shared variable configured with logging enabled
    - data changing by much more than the deadband
    - new value written by Datasocket Write at a steady 1 Hz
    - historic data retrieved by Read Traces
    - Distributed System Manager shows correct and changing values continuously as they are written

    Meg K. B. , 
    It sounds like you are experiencing Time Stamp Counter (TSC) Drift as mentioned in the KB's for the AMD Multi-Core processors. However, according to this wikipedia article on TSC's, the Intel Core 2 Duo's "time-stamp counter increments at a constant rate.......Constant TSC behavior ensures that the duration of each clock tick is
    uniform and supports the use of the TSC as a wall clock timer even if
    the processor core changes frequency." This seems to suggest that it would be not be the case that you are seeing the issue mentioned in the KBs.
    Can you provide the exact modle of the Core 2 Duo processor that you are using?
    Ben Sisney
    FlexRIO V&V Engineer
    National Instruments

  • I am trying to log data from 4 voltage input signal using labview, but when i use DAQ assistant i am able to log data from one signal at a time only.

    I am trying to log data from 4 voltage input signal using labview, but when i use DAQ assiatant i am able to log data from one signal at a time only.I am trying to get all 4 input data to logged in a single file againt time. I am new to Labview, I need to sample this data within a couple of days can someone help please.

    Naveen
    Check out the info in the Analog Input section of the document linked below.  (Ignore the part about Global Channels.)  In Figure 5, notice that you can select multiple channels while holding <Ctrl> or <Shift>.
    Developer Zone Tutorial: NI-DAQmx Express VI Tutorial
    Kyle B  |  Product Support Engineer  |  ni.com/support

  • I need to start and stop logging based on a digital input event(or analog if necessary), log data for several seconds prior to the event, and have the data file close at the end of event and increment the filename for the next logging event.

    I don't know if this can be done with VI Logger or need to use Labview V7.1.

    After browsing through the VI Logger User Manual, it looks like the triggering that you are hoping to accomplish is possible. However, incrementing the filename for the next logging event is not going to be possible. VI Logger does exactly what its name tells - logs data. I don't think the automation that you are hoping to accomplish is possible.
    For help with setting up your application, if you do choose to stay with VI Logger, make sure to chek out the Getting Started with VI Logger Manual.
    Best of luck.
    Jared A

  • How to delete Change log data from a DSO?

    Hello Experts,
    I am trying to delete the change log data for a DSO which has some 80 Cr records in it.
    I am trying to follow the standard procedure by using the process chain variant and giving the no.of days but somehow data is not getting deleted.
    However the process chain is completing successfully with G state.
    Please let me know if there are any other ways to delete the data.
    Thanks in Advance.
    Thanks & Regards,
    Anil.

    Hi,
    Then there might something wrong at your Chang log deletion variant.
    can you recreate changlog deletion variants and set them again.
    Ty to check below settings with new variant.
    Red mark - won't select
    Provide dso name and info area, older than and select blue mark.
    blue mark - it will delete only successfully loaded request which are older than N days.
    Have you tested this process type changlog deletion before moving to prod per your data flow?
    Thanks

  • Using event risen to log data into citadel

    Hi all,
    I have an HMI application in LV & DS 8 reads My OPC items, and log data, alarms and events into citadel. Knowing Citadel is event-driven, I want to use this event to distinguish a change in database and update my Historical Alarm & Even List in the HMI front panel instead of ever polling the database.
    I really appreciate any help.

    Can you post more information on what you are doing? I haven't done much with Citadel but I thought that it is aimed at logging data as it changes, i.e. all of the data logged in there will be different else it wouldn't have been logged in the first place?!
    There are block diagram functions that allow you to read the traces back and this is all you need. Check out the examples that come with the DSC module.
    Let me know if I can help you further.

  • Best way to log data

    I have an application that receives data from a source, and I would
    like to create and maintain a log file with this data. Small bits of
    data will be received at least every minute, and often once every
    second. The user can also view the logged data at any time.
    Lastly, each entry is timestamped, and I would like to be able to
    remove log entries that are x hour/days old.
    What I would like advice on is what is the bext way to accomplish this?
    Clearly a bad way to do this is every time I get data, read the log in,
    remove old entries, rewrite all the remaining entries, and finally
    append the new entry. This uses way too many file operations.
    I have briefly looked at the java.util.logging stuff, but it appears that
    the purpose of that is more for code debugging/etc. It also doesn't
    appear that there are methods to read the logs. So, this does not
    look like an "easy way out".
    I know how to append to a file, but I am not sure if I should leave
    the file open during execution of the program and simply flush
    the stream/buffer, or open and close the file everytime I write.
    The latter is clearly more expensive, but safer.
    I don't know how to delete data from the beginning of a file.
    To summarize, what is the best way to read and write data to
    a file such that:
    1) the data is appended to the end of the file (easy)
    2) the data is removed from the beginning of the file
    3) the data that is written is not lost of the program crashes/etc.
    4) the whole logging business is not too expensive
    Any suggestions?
    Thanks,
    Chuck.

    Here's what we did at my last job:
    Incoming messages are logged to disk via FileOutputStream (maybe with BufferedOutputStream encasing that, I don't remember) this outputstream is not closed until the applet is stopped. System.out is also reassigned to this fileoutputstream to capture all messages.
    At the same time, there is an InputStream reading from that file. As data is read, we stick the text into a TextArea.
    When the TextArea size hits some certain amount (maybe 20,000 characters) we'd remove ... maybe 5000 from the top. Log stays the same tho
    When the day rolls over, we switch log files
    You're questions:
    1) the data is appended to the end of the file (easy)
    Yes. But if you're not using streams, you should check that out.
    2) the data is removed from the beginning of the file
    That's pretty easy. Open the file for reading, open a new file for writing. Read the first n bytes but don't write them. Then write the rest
    3) the data that is written is not lost of the program crashes/etc.
    Data should be fine if it's logged to disk
    4) the whole logging business is not too expensive
    Saving to disk isn't very expensive at all. In fact, normally writing to disk is slow enough that stuff just gets put into a buffer somewhere to get sent to the disk and the processor goes on with the program.

  • .tmp file is created by NI Report generation toolkit for logging data to MS Excel

    Hi,
    I am getting ".tmp" file while logging data to MS Excel by NI Report generation toolkit. Instead of assigned file name, toolkit is generating a junk value with .tmp extension, but I can able to open this .tmp file with MS Excel.
    Can anyone help to solve this issue?
    Thanks,
    Thirumala

    Hi Thirumala,
    You may experience issues when you try to save a Microsoft Excel file if one or more of the following conditions are true:
    1. You save an Excel file to a network drive where you have restricted permissions.
    2. You save an Excel file to a location that does not have sufficient drive space.
    3. The connection to the Excel file has been lost.
    4. There is a conflict with an antivirus software program.
    5. You save an Excel file that is shared.
    6. The 218-character path limitation has been exceeded when you save an Excel file.
    7. The Transition Formula Evaluation feature is turned on in Excel.
    8. The file was created from a template that contains embedded objects.
    Hope this will help to solve your problem.
    Thanks,
    Sanad MM

  • How to determine Default Table Logging (log data changes )

    Does anyone know how to view exactly what tables and related data fields have change logging enabled by default? I know that some of the standard reports will produce "edit reports" show who changed what field, when ,old and new values, etc, but I don't know how to determine where the data is retrieved from.
    For example: If I look in the ABAP Dictionary at table LFA1, technical settings, it shows that log data changes is not "checked" or enabled. But if I run the standard AR Master Data Change Report, I get output showing valid field changes.
    I have seen other threads that refer to SCU3 but I can't determine the above this from report.
    Any assistance would be greatly appreciated.

    Hi Arthur,
    As far as I am aware, these are 2 different things. 
    There is table logging which is at the table level & if activated (i.e. it's listed in table DD0LV, PROTOKOLL=X and the table logging parameter is set in the system profile/s).
    The second one is programatical logging for change documents when data is maintained though a program that has been written to include a log.  I'm not sure how to identify a complete lit of these though unfortunately.
    Hope that is of some assistance.

  • Sending log data to two different files using log4j

    Hi,
    Can some one please help me with my problem I have here?
    I want to send log data to two diffrent files depending on the logging level such as DEBUG and WARN.
    How can you configure this in log4j.properties.
    Please post sample code for log4j.properties to achieve this.
    Thanks in advance.
    rsreddych

    Hi,
    Finally, I found the solution to this problem my self.
    What you need to do is define two loggers in the application, and set two priority levels to these loggers and define two out put files to these loggers. Deploy the war file, restart application server and you are good to go.
    This seems to be working for me. Only glitch I found is, the out put in
    the second file is displaying one space character at the start of line starting from second line (First line don't have this problem). This is odd. It may be because of my faulty code. Any how thanks for you all.
    rsreddych

  • Archived LOG data  - SLG1

    Hi All,
    I have one issue on LOG data.
    I have to fetch archived log data with external id
    By SLG1, we can get log data.
    But i need to develop this scenario in logically in program.
    We can find the records (EXTERNAL ID) is archived or not with FM  BAL_ARCHIVE_SEARCH.
    But how to get log data of  the record?
    For Ex:
    My External ID :   123456789
    After executing the Above FM ,it is confirmed as Archived record.
    But now i have to fetch the log data of this record(log data means messages).
    Please tell me how to fetch these message(log data)?
    is there any FM or Sample logic?
    Thanks & Regards
    Sathish

  • Table - Issue with Logging Data Changes

    Hi Experts,
    My client's requirement is to log data changes happened in a table which is critical. I've selected 'Log data changes' check box in technical settings of the table. Now, I'm able to see log for all the changes i did after that. But, I'm facing following issues. Kindly help me in fixing the same.
    1. The table is having two fields with same data element. In the change log SCU3, under the field name, field label mentioned in the data element is getting displayed. As, the data element is same for two fields, its difficult to find out which particular field is changed. Is there any way to display table field name instead of field label from data element?
    2. Sometime, even there is change in the data record, I'm able to see a log record in the change log with caption 'Data record unchanged'. What might be the problem and how to resolve?
    Thanks in Advance,
    Siva Sankar.

    Hi Moha Nan,
       You just use ABAP to change the table P? In this way I think it is not change to X table.
    You can upload master data to add navigation,it is a good way to bulid the SID of P table and X
    table .
      Hope it is help to you!

  • Logging data after a trigger with Lookout Direct

    Hi,
    I would like to log data with Lookout Direct after a trigger input (not periodically or continuously).  I am using Lookout DIrect version 4.5.1 build 19 and a Direct Logic 250 PLC.
    Does anyone have suggestions on how to do this?  I would prefer that this data be logged into Excel.  I have 24 sensors connected to the PLC and each time a sensor transitions from hi to low I would like to log the time of transition. 
    Currently I have individual spreadsheet storage objects for each sensor as well as individual latchgates to indicate when logging has been completed.  In the PLC code there is a state machine for each individual sensor as well and one of the states waits for an acknowledgement from Lookout that data logging has been completed before moving on to the next state (I will have to dig a bit deeper to remember exactly why I needed to do that).
    I am hoping there is a more traditional approach that is easier than what I am doing.  One of the problems I have been facing is Lookout Direct crashing every few days and I suspect it is because the sensors are often sensed within milliseconds of each other and opening/closing so many files is causing problems.  I worked through a list of possible reasons that Lookout may be crashing (provided by tech support) and I am nearly convinced I am just asking too much of the program...
    Any help will be greatly appreciated
    Thank you,
    David

    In case someone can help with this, here is a bit more information about my application and the PLC/Lookout code I have developed:
    Actuators have two positions, nominal and folded.  Prox sensors are used to monitor the position of actuators.  12 actuators can be monitored simultaneously.  The time at which prox sensors are sensed high is recorded so that actuator speed and actuation success is logged. 
    The PLC code consists of 12 separate state machines, each with the following 8 states:
    State 1
      System reset or nominal timer reset
      Wait for nominal prox release
    State 2
      Nominal prox released
      Wait for folded prox sense
    State 3
      Folded prox sensed
      Wait for folded ack from Lookout (acknowledges that timer value has been logged)
    State 4
      Folded ack from Lookout received
      Wait for folded timer reset (this state is active for one scan only)
    State 5
      Fold-in timer reset
      Wait for folded prox release
    State 6
      Folded prox released
      Wait for nominal prox sense
    State 7
      Nominal prox sensed
      Wait for nominal ack from Lookout (acknowledges that timer value has been logged)
    State 8
      Nominal ack received from Lookout
      Wait for nominal timer reset (this state is active for one scan only)
    Lookout acknowledges that timer values have been read and saved with LatchGates.  Lookout uses a SpreadSheet Storage Object to save the PLC timers when the PLC enters states 3 or 7 (prox sensor triggered).  The logged member of the SpreadSheet Storage Object is used to change the state of the LatchGates which, in turn, signal the PLC to proceed to the next state.  When the folded file is saved, the nominal LatchGate is turned off and the folded LatchGate is turned on and vice-versa for the nominal file.
    The LatchGate/SpreadSheet Storage combination is what I am hoping to improve upon.  I believe Lookout is crashing when 12 SpreadSheet Storage Objects log to 12 different files during the same 1 second period of time.
    If anyone has suggestions of a way to log this data in the PLC memory or a software package better suited for this application, please let me know!  I believe this would be simple with LabVIEW, unfortunately obtaining the additional hardware and software that I would need hasn't been easy! 