Module Pool screen copy from 4.7 system to 4.5 system

Hi can any body tell me how can i upload screens from 4.7 environment to 4.5 environment.
Due to version incompatable i am unable to do.

Hi
I've downloaded the file from dynpro, the first lines are:
  THIS FILE IS GENERATED BY THE SCREEN PAINTER.
  NEVER CHANGE IT MANUALLY, PLEASE !
%_DYNPRO
SAPMF05A
0100
700                <---- Basis SAP Release
Try to change the version and insert the rel of 4.50
Max

Similar Messages

  • Copying from report output to a module pool screen

    Hi to all experts
    My requirement is to call a transaction when i click a button in module pool programme .when i execute that transaction an alv report is displayed and user selects some records that should be copied over to the module pool screen.

    Yous should use ALV OOps concept to capture the selected data in the ALV report , and once you return back you can update yr module pool .

  • Call module pool screen from ABAP Webdynpro

    Hi All
    I designed one screen in normal classical dynpro in SE80 for module pool program. I want to call that screen layout design in webdynpro view layout.
    So please help me how can i call that module pool screen from my ABAP webdynpro 

    Hi
    Thank you for your great replay. But Mr Ramakrishnappa and Mr Katrice as your reference i go through that but when i insert the program name and screen number program is end with a run time error saying
    dynamic type conflict when assigning reference.
    Please refer the below snap shot

  • Call LSMW from a Module pool screen

    Hi SAP gurus,
    In order to call an LSMW from a module pool screen, there is a Function module which I have used earlier, but unable to recollect it. Can someone please tell me the FM which we need to use ?

    Sudhakar,
    Create an LSMW and assign it to a tcode and then call this tcode from the module pool program so that it  will skip all the screens just by allowing the user to input the files and run the lswm.
    Regarding the FM I have no idea.
    K.Kiran.

  • Regarding exit from the module pool screen

    h experts,
    i have developed a module pool report in which in the selection screen i have four fields which are mandatory ,when i execute the program without entering in the selection screen it do not allow to come out of the module pool screen ...what i want that without entering any input in the selection screen if i press exit button push button it will allow to come out of the screen for this what sud i do plz help me....

    Hi
    keep a button called <b>EXIT</b> on the screen
    Make the function type of that field as <b>E</b>
    in Flow logic write
    PROCESS AFTER INPUT.
    Forced Exit from the transaction from screen
      MODULE exit AT EXIT-COMMAND.
    double click on exit module and
    then in PAI write
    *&      Module  exit  INPUT
    Exit from the Transaction
    MODULE exit INPUT.
      CASE okcode.
        WHEN 'EXIT' OR 'CANCEL'.
          CLEAR okcode.
          LEAVE PROGRAM.
      ENDCASE.
    ENDMODULE.                 " exit  INPUT
    <b>Reward points for useful Answers</b>
    Regards
    Anji

  • Trigger a workflow from module pool screen at save button

    Hi,
    I am new to workflow.Please help me.My requirement is trigger a custom workflow from module pool screen at save button.
    Scenario is: Create a Z screen for material creation and after pressing save button workflow should trigger to approver and approver emailid should be fetch from Z table and have to provide a link in work flow for Z t-code which displays a report of material pending for approval..
    Please suggest me process how i can acheive this..
    Thanks

    Hi,
    If you're using standard bapi's to save the material, you can then use either the standard events which are already triggered or you coul add a change document for material changes or creation.
    Then this event can be the trigger of your custom workflow.
    Kind regards, Rob Dielemans

  • Display Continuous Fluctuations in Input Data in Module Pool Screen

    Dear All,
    We are working on a Weighbridge Interface scenario, where the weighbridge is sending data to a digitizer, which is connected to the COM port of a PC. The objective is to read the data from the digitizer, and display in a Module pool screen. However, there is one more requirement: the weight may fluctuate until it stabilizes, and the fluctuations have to be displayed on screen. For example, the tare weight of a vehicle may be 12.4 TON, but when the vehicle is standing on the weighbridge, the weight may vary from 10.4 to 12.4 TON. The idea is to capture the stable weight, so that any discrepancies can be avoided. In the current IT system implementation, the fluctuations in the weight are displayed. But using ABAP, can these fluctuations be captured? For example, we may design a screen containing a field for capturing the weight, and the weight displayed there automatically refreshes as soon as there is a change in the digitizer reading. Is this possible to achieve? If so, how?
    Awaiting answers.
    Thanks and Regards,
    Sid

    Hi Sid,
    just a suggestion for the refreshing of an ABAP screen: you can use class CL_GUI_TIMER, but it only handles whole seconds, i.e. 1 second, 2 seconds and so on, but not 0.5 seconds...
    An example of an ABAP listing could be the following:
    *& Report  ZZAVV001
    REPORT  zzavv001 NO STANDARD PAGE HEADING.
    CONSTANTS: c_yes(1) TYPE c VALUE 'X'.
    DATA: BEGIN OF t_bseg OCCURS 0.
            INCLUDE STRUCTURE bseg.
    DATA: END OF t_bseg.
    data: d_num_bkpf type i,
          d_num_bseg type i.
    PARAMETERS: interval TYPE i DEFAULT 5.  "meaning 5 seconds
    *       CLASS lcl_receiver DEFINITION
    CLASS lcl_receiver DEFINITION.
      PUBLIC SECTION.
        METHODS:
          handle_finished FOR EVENT finished OF cl_gui_timer.
    ENDCLASS.                    "lcl_receiver DEFINITION
    * Global data
    DATA:
      test       TYPE i,
      receiver   TYPE REF TO lcl_receiver,
      timer      TYPE REF TO cl_gui_timer.
    START-OF-SELECTION.
      CREATE OBJECT timer.
      CREATE OBJECT receiver.
      SET HANDLER receiver->handle_finished FOR timer.
      timer->interval = interval.
      CALL METHOD timer->run.
      PERFORM load_data.   "or whatever you have to do to read the weight
      PERFORM show_list.   "or whatever you have to do to print the weight you've read
    *       CLASS lcl_receiver IMPLEMENTATION
    CLASS lcl_receiver IMPLEMENTATION.
      METHOD handle_finished.
        PERFORM carga_datos.
        PERFORM muestra_listado.
        CALL METHOD timer->run.
      ENDMETHOD.                    "handle_finished
    ENDCLASS.                    "lcl_receiver IMPLEMENTATION
    *&      Form  load_data
    *       text
    FORM load_data.
      clear: d_num_bkpf,
             d_num_bseg.
      select single count( * )
        into d_num_bkpf
        from bkpf.
      select single count( * )
        into d_num_bseg
        from bseg.
    ENDFORM.                    "load_data
    *&      Form  show_list
    *       text
    FORM show_list.
      get time.
      skip to line 1.
      position 1.
      write: / 'Date / Time:', sy-datum, sy-uzeit.
      write: / 'Number of BKPF records:', d_num_bkpf.
      write: / 'Number of BSEG records:', d_num_bseg.
    ENDFORM.                    " show_list
    Okay, it's just a tiny code snippet, but I hope it may help you by designing auto-refreshing screens.
    Kind regards,
    Alvaro

  • How to use table maintenance view in module pool screen

    hi ,
    want to use table maintenance view in a module pool screen so that i can edit, insert, delete and update date in to the ztable.please help.

    You can simply call it via SM30.   Or you can call the table maintence view from any program(report or module pool) using a function module.
      call function 'VIEW_MAINTENANCE_CALL'
           exporting
                action                       = 'U'
                view_name                    = 'Z_Table_Name'
           exceptions
                client_reference             = 1
                foreign_lock                 = 2
                invalid_action               = 3
                no_clientindependent_auth    = 4
                no_database_function         = 5
                no_editor_function           = 6
                no_show_auth                 = 7
                no_tvdir_entry               = 8
                no_upd_auth                  = 9
                only_show_allowed            = 10
                system_failure               = 11
                unknown_field_in_dba_sellist = 12
                view_not_found               = 13
                others                       = 14.
    Regards,
    RIch Heilman

  • How to insert tabstrip control in module pool screen painter

    Hi all!
    plz tell e how to use tabstrip control in module pool screen painter.Also plz give me an example program using tabstrip control.

    To insert tabstrip just open layout of screen and press on the tabstrip button there .
    Use this souce code further to activate it .
    CONTROLS tabstrip TYPE TABSTRIP.
    DATA: okcode TYPE sy-ucomm,
    dynnr TYPE sy-dynnr,
    flag type flag,
    active like tabstrip-activetab .
    call SCREEN 100.
    *& Module USER_COMMAND_0100 INPUT
    text
    MODULE USER_COMMAND_0100 INPUT.
    data: lv_okcode type syucomm.
    lv_okcode = okcode.
    clear okcode.
    case lv_okcode.
    WHEN 'TAB1'.
    dynnr = '0110'.
    WHEN 'TAB2'.
    dynnr = '0120'.
    WHEN 'TAB3'.
    dynnr = '0130'.
    WHEN 'TAB4'.
    dynnr = '0140'.
    WHEN 'TAB5'.
    "check authorization, if authorization fails
    flag = 'X'. "set the global flag
    active = 'TAB1'. "store active tab in global variable
    dynnr = '0110'. "set the screen number
    WHEN 'BACK' or 'EXIT'.
    leave program.
    ENDCASE.
    IF lv_okcode(3) = 'TAB'.
    tabstrip-activetab = lv_okcode.
    ENDIF.
    ENDMODULE. " USER_COMMAND_0100 INPUT
    *& Module STATUS_0100 OUTPUT
    text
    MODULE STATUS_0100 OUTPUT.
    SET PF-STATUS 'MAIN'.
    SET TITLEBAR 'xxx'.
    IF tabstrip-activetab IS INITIAL OR
    dynnr IS INITIAL.
    tabstrip-activetab = 'TAB1'.
    dynnr = '0110'.
    ENDIF.
    "set the activetab explicilty here
    if flag eq 'X'. "from authorization failure
    tabstrip-activetab = active. "'TAB1'
    clear flag.
    endif.
    ENDMODULE. " STATUS_0100 OUTPUT

  • Displaying MIR4 attachment list TIF image in module pool screen

    Hi All,
    I have a screen with a custom container and I tried to call a TIF image from MIR4 which is in attachment list(which is stored in archived link).
    I need a function module to display this image in my Module pool screen using the container.
    I tried using below code
    * Create controls
         CREATE OBJECT container_1
           EXPORTING
             container_name = 'CONTAINER'.
    *    create object container_2
    *      exporting container_name = 'PICTURE_CONTROL_2'.
         CREATE OBJECT PICTURE_CONTROL_1
           EXPORTING
             parent = container_1.
    *    CREATE OBJECT PICTURE_CONTROL_2 exporting parent = container_2.
    CALL METHOD PICTURE_CONTROL_1->LOAD_PICTURE_FROM_URL
           EXPORTING
    *    URL    = 'SAPR3://984BE16932C81EE3B2AA1E3B0D12C6FF'
    *      URL    = 'file://E:\Personal\New_Passport4.jpg'
    *       URL    = 'SAPR3://984BE16932C81EE3B2BDF8E44B035648.TIF'
    *URL    = 'SAPR3://SAPR3CMS/get/100/Z1/984BE16932C81EE3B2BDF8E44B035648//.TIF'.
         URL    = 'SAPR3://WebRepository/0020698212/DEMOWORD97SAPLOGO?Version=00000'
         IMPORTING
              RESULT = lv_result.
    CALL METHOD PICTURE_CONTROL_1->set_display_mode
         EXPORTING
           display_mode = PICTURE_CONTROL_1->display_mode_fit_center.
    But I am able to display this URL    = 'SAPR3://WebRepository/0020698212/DEMOWORD97SAPLOGO?Version=00000' and not able to display my archive link image which is in TIF.
    note: Display image of Arc.link Doc.type ZBUSI_TIF (doc.class TIF)
    Please help me on this.
    Thanks
    Geetha Charan

    Hi sai,
    Please refer th procedure.
    For the select-options you might have defined a selection screen.
    Next you can fetch the entire data that you wanted to display in a module pool into an internal table.
    you can call the screen you defined for o/p upon the selection.
    Then, You define a screen XXXX  and a table control in the scree, and in the PAI module of the screen
    you write a chain end chain processing in which you can display the contents of your internal table.
    OR
    if you want the selection also to be in the module pool,  then for displaying the O/P you can definr a sub-screen of the initial screen and you can call that sub-screen on selcting, which can be done with a function code.
    Hope this helps

  • Expand/collapse button functionality on module pool screen

    Hi ,
    I want to design a module pool screen with a expand/collapse button on it.
    The desired functionality associated with this button would be something similiar to that available in ME21N screen. When the expand button is clicked it should open up a section of screen that allows the user to enter some parameter. Based on this parameter some selections from DB can be perfomed and then displayed below it.
    Any pointers on how to achieve this? Any kind of help would be appreciated.
    Regards-
    Harmeet Singh.

    example for three pushbutton with expand collapse .
    First of all define your push button as output field with icon tick in the pushbutton characteristick,
    then define this pushbutton in top_include
    include <icon>.
    data : push_a1 like icons-l4,
             push_a2 like icons-l4,
             push_a3 like icons-l4.
    data : a1 ,
             a2,
             a3.
    in pai of the screen
    suppose i had assign function code a1 ,a2 , a3 for repective pushbutton
    module user_command_9002 input.
      okcd = ok_code.
      clear ok_code.
      case okcd.
        when 'A1'.
          if a1 is initial.
            a1 = 'X'.
          else.
            clear a1.
          endif.
        when 'A2'.
          if a2 is initial.
            a2 = 'X'.
          else.
            clear a2.
          endif.
        when 'A3'.
          if a3 is initial.
            a3 = 'X'.
          else.
            clear a3.
          endif.
      endcase.
    endmodule.                 " USER_COMMAND_9002  INPUT
    define three seprate screen -group for three pushbutton say a1 a2 a3
    during pbo you can directly assign name of icon .
    if a1 is initial.
        push_a1 = icon_collapse.
      else.
        push_a1 = icon_expand.
      endif.
      if a2 is initial.
        push_a2 = icon_collapse.
      else.
        push_a2 = icon_expand.
      endif.
      if a3 is initial.
        push_a3 = icon_collapse.
      else.
        push_a3 = icon_expand.
      endif.
    loop at screen.
        if screen-group1 = 'A1'.
          if a1 = 'X'.
            screen-invisible = 1.
            screen-input = 0.
            modify screen.
          else.
            screen-active = 1.
            screen-invisible = 0.
            screen-input = 1.
          endif.
        elseif screen-group1 = 'A2'.
          if a2 = 'X'.
            screen-invisible = 1.
            screen-input = 0.
            modify screen.
          else.
            screen-active = 1.
            screen-invisible = 0.
            screen-input = 1.
          endif.
        elseif screen-group1 = 'A3'.
          if a3 = 'X'.
            screen-invisible = 1.
            screen-input = 0.
            modify screen.
          else.
            screen-active = 1.
            screen-invisible = 0.
            screen-input = 1.
          endif.
        endif.
      endloop.
    regards,
    Alpesh
    Edited by: Alpesh on May 28, 2009 10:28 AM

  • Module-pool screen field value under POV event

    Hi All,
    I have one issue...please suggest me solution for this.
    In module-pool program i have one screen(1000) which has one field(hrname_1000).
    Under this event:
    PROCESS ON VALUE-REQUEST.
    FIELD hrname_1000  MODULE hrname_1000.
    under this module hename_1000 i have used F4IF_INT_TABLE_VALUE_REQUEST to put a search help for field hrname_1000.
    after that i am trying to retrive HR related stuff's based on the field on module-pool i.e i am using hrname_1000 in the where condition.
    but problem is that im not getting value for hrname_1000 which im giving in the module-pool screen.
    thats y my select query is not working.
    Where as im getting values for the hrname_1000 under PBO & PAI.
    It will look like below.
    PROCESS ON VALUE-REQUEST.
    FIELD hrname_1000  MODULE hrname_1000.
    (under the above module)
      SELECT DISTINCT ename plans FROM pa0001 INTO CORRESPONDING FIELDS OF TABLE itab WHERE stell = '50001026'.
          LOOP AT itab INTO wa WHERE ename = hrname_1000.
          ENDLOOP.
    Please suggest
    Thanks & regards
    Ansumesh

    In some of the cases the screen field is present in the screen but not holding the value in the required structure or field.
    so here u need to check the option of reading the screen field values explictly..
    //once u hit an enter and do the f4 i think the value will be there ...but if u dont hit enter and do an F4 the value cannot hold and i think u r in this case ..
      1.Fill the screen field name in the structure dynpread.
    DATA: BEGIN OF DYNP_VALUES OCCURS 10.
            INCLUDE STRUCTURE DYNPREAD.
    DATA: END   OF DYNP_VALUES.
    DYNP_VALUES-FIELDNAME = 'HRNAME_1000'.
      APPEND DYNP_VALUES.
    * read screen values
      CALL FUNCTION 'DYNP_VALUES_READ'
        EXPORTING
          DYNAME     = HELP_REPID  "call the repid of ur prog
          DYNUMB     = HELP_DYNNR "pass the screen number
        TABLES
          DYNPFIELDS = DYNP_VALUES
        EXCEPTIONS
          OTHERS     = 1.
    now dynp_values hold the field name and field value of the screen .
    now
    SORT DYNP_VALUES BY FIELDNAME.
        READ TABLE DYNP_VALUES WITH KEY 'HRNAME_1000' BINARY SEARCH.
        IF SY-SUBRC EQ 0.
          HELP_XXXX = DYNP_VALUES-FIELDVALUE. "store the value into a variable
          TRANSLATE HELP_XXXX TO UPPER CASE.               
        ENDIF.
    Now check the code with the value if its getting populated which once there will make ur select work ..
    Vijay..

  • Module pool screen field should default without pressing enter

    Hi
    I have got a main module pool screen which has a tabstrip with four tabs.
    There are 2 fields in the main screen when we select from F4 for the first field then the field 2 should default in case of a condition.
    This happens only when i press enter. I want the second field to change  as soon as the first field is selected.
    How do I trigger the PAI as soon as the field 1 is selected.
    eg:                           Field 1 :  i/p
                                    Field 2 : display
                                   Field 3 : i/p
    On F4 for field 1  say i select value 'A' then the valu for field 3 should default to value 'B'.  Also field 2 should be displayed based on combination  of field 1 and field 2. But now it does it only on pressing enter.
    How do I solve this problem?Also if i select field 1 value A and dont press enter and go to the subscreen tab then it does not do any thing. It allows to go on the subscreen tab. But actually it should default the field 3 value. It does it only when I press enter.
    Also the F4 is from dictionary that is the screen fields are from dictionary. I have not created any F4 for the fields.
    Please help me solve this problem
    Regards,
    mozila

    Hi
    You can achieve this using List Box only not by Input Field. Since Input field doesn't trigger automatic PAI/PBO
    Go through the below thread
    populate drop down menu based on entry in another field
    or an alternative is--> In PBO use POPUP_GET_VALUES Fm to get the First input field based on that you can enter further values
    unicode error
    Cheerz
    Ram

  • How to create select-options on module pool screen

    Hi all
    I want get a range of values from the user from the module pool screen.
    Is there any element available on module pool screen like select options on the selection screen of reports.
    reply me ASAS.
    Thanks.

    hi krishna
    actually I want to display the details of PO numbers from 45000100 to 45000150. user will enter this range on the module pool screen just as we enter on the selection screen of report. My question is do we have a button like select-option on the module pool screen.
    Plz . reply me ASAP.
    Thanks.

  • Display Progress Indicator in Module-pool Screen

    Hi,
    I want to draw a Progress Indicator (fixed progress bar) in my own module pool screen. (It will be a little graphic, that will represent total percentage of the work that has been done till date.)
    I tried to take reference from the existing programs:
    GFW_PROG_PIE
    GFW_DEMO_PRES1
    GFW_PROG_BAR
    DEMO_GFW_PRES_SHOW u2026
    -but these programs can draw only charts (pie, bar etc).
    Looking for your help!!!
    Thanks,
    Tushar

    Hi,
    you can use Function Module SAPGUI_PROGRESS_INDICATOR.
    Hope this helps!
    Regards
    Mark-André

Maybe you are looking for

  • How to install windows 8 using bootcamp?

    I am trying to install windows 8 on my Macbook Pro (Lion) using bootcamp. Of course in the bootcamp setup there is only the option to install windows 7 which I do not want, and if I try it anyways with the Win8 DVD I have it says it can't find the DV

  • Help needed on Mac Book pro boot issue.

    2015-04-13 20:20:31 +0530: Starting repair tool: 2015-04-13 20:20:31 +0530: Checking prerequisites 2015-04-13 20:20:31 +0530: Checking the partition list 2015-04-13 20:20:31 +0530: Adjusting partition map to fit whole disk as required 2015-04-13 20:2

  • ERROR IN ASSIGNMENT OF DOCUMENT NUMBER

    Dear all, While making a MIRO transaction my user is getting the subject error. Can you guide me exactly how to rectify this error. Message # 8i130 Regards, Sudish SAP Helpdesk

  • Z600 Max SATA hard drive ?

    Hi, I purchased a refurbished Z600 work station and have not been able to determine what the max size SATA hard drive I can install in the system. The operating system is Windows 7 Professional 64-bit. Thanks . . .

  • A wierd problem in a user exit in IT0030

    hello, In infotype 0030 we developed a new field. Then we developed a user- exit which delimits a record after opening a new one (the info typy is has time constraint=3). When the user looks with the overview icon or the display icon it's seems as if