Nested functions in XML Publisher
Hello Everyone,
I am building a template in MS Word, using the Oracle XML Publisher Template Builder.
I have data from an Accounts Receivable report that is coming out at 1234,99. I would like it to come out as 1,234.99. So I would want
1) The comma as a thousands separator.
2) Instead of the comma as a decimal separator, I want the period as a decimal separator.
I can use this for the comma thousands separator:
<?format-number:VAL;'999G999D99'?>
And I can use this to replace the decimal separator from a comma to a period (thanks to the forums):
<?xdofx:replace(VAL,',','.')?>
Can I combine both of these functions together? I am not sure of the syntax.
Thanks...colin
<?format-number(xdoxslt:replace(VAL,’,’,’.’),'##,##0.00')?> for
1234,99
4444444444,55gives
1,234.99
4,444,444,444.55
Similar Messages
-
Cannot see or switch responsibilities such as Functional Administrator, XML
Dear Experts,
Please help here , Cannot see or switch responsibilities such as Functional Administrator, XML Publisher Administrator etc after logging in as sysadmin user. However, we we query sysadmin user from security>user>define. we see that these responsibilities are already assigned to sysadmin user.
I created one new user and assigned some responsibilites. After logging in with new user account, cannot see any responsibility at all.
thanks
AtifAtif,
Please see old threads for similar discussion -- http://forums.oracle.com/forums/search.jspa?threadID=&q=Missing+AND+Responsibilities&objID=c3&dateRange=all&userID=&numResults=15&rankBy=10001
Please search the forum before posting similar questions.
Thanks,
Hussein -
XML Publisher nested grouping, sum and order by question
Please help in nested group by, sum and order by question
My Data look like this:
<Header>
<Line1>
<Part Number></Part Number>
<Component>
<Component1></Component1>
<Component1 Amount></Component1 Amount>
</Component>
<Component>
<Component2></Component2>
<Component2 Amount></Component2 Amount>
</Component>
</Line1>
<Line2>
<Part Number></Part Number>
<Component>
<Component1></Component1>
<Component1 Amount></Component1 Amount >
</Component>
<Component>
<Component2></Component2>
<Component2 Amount ></Component2 Amount >
</Component>
</Line2>
</Header>
I want to print report which is:
1. Group by part number, component and sum the amount for a part number/component
2. Order by part number, component
Here is rtf file for XML publisher report
<?for-each-group:G_LINES;PART_NUMBER?>
<?sort:G_LINES;PART_NUMBER;'ascending';data-type='text'?>
<?if:BREAKDOWN_COUNT>0?>
Part Number: <?PART_NUMBER?> Quantity: <?sum (current-group()/SHIP_QTY)?> Part Count:<?count(current-group()/PART_NUMBER)?> Breakdown Count:<?count(G_BREAKDOWN/COMPONENT)?>
<?for-each:current-group()?>
<?for-each-group:G_BREAKDOWN;COMPONENT?>
Component: <?COMPONENT?> Price: <?COMPONENT_PRICE?>
<?end-for-each?>
<?end-for-each?>
<?end if?>
<?end-for-each?>
If I add <?sort:G_BREAKDOWN;COMPONENT;'ascending';data-type='text'?> inside G_BREAKDOWN grouping it gives error.
My XML data file
<?xml version="1.0"?>
<!-- Generated by Oracle Reports version 6.0.8.25.0 -->
<NI_COMMERCIAL_INVOICE_XMLP>
<LIST_G_HEADER>
<G_HEADER>
<COMM_INV_NUMBER>C/901000598</COMM_INV_NUMBER>
<COMM_INV_VERSION_NUMBER>1</COMM_INV_VERSION_NUMBER>
<SHIP_FROM_NAME>National Instruments Europe Corp.</SHIP_FROM_NAME>
<SHIP_FROM_ADDR>H-4031, Debrecen, Hatar ut 1/A</SHIP_FROM_ADDR>
<SHIP_FROM_CITY></SHIP_FROM_CITY>
<SHIP_FROM_STATE></SHIP_FROM_STATE>
<SHIP_FROM_POSTAL_CODE></SHIP_FROM_POSTAL_CODE>
<SHIP_FROM_COUNTRY>Hungary</SHIP_FROM_COUNTRY>
<SHIP_TO_NAME>National Instruments Corporation (NIEC)</SHIP_TO_NAME>
<FORMATTED_SHIP_TO_ADDR>11500 N Mopac Expwy
Austin, TX 78759-3504
United States</FORMATTED_SHIP_TO_ADDR>
<SHIP_TO_ADDR1>11500 N Mopac Expwy</SHIP_TO_ADDR1>
<SHIP_TO_ADDR2></SHIP_TO_ADDR2>
<SHIP_TO_ADDR3></SHIP_TO_ADDR3>
<SHIP_TO_ADDR4></SHIP_TO_ADDR4>
<SHIP_TO_CITY>Austin</SHIP_TO_CITY>
<SHIP_TO_STATE>TX </SHIP_TO_STATE>
<SHIP_TO_POSTAL_CODE>78759-3504</SHIP_TO_POSTAL_CODE>
<SHIP_TO_COUNTRY>US</SHIP_TO_COUNTRY>
<SHIP_TO_EMAIL_ADDR></SHIP_TO_EMAIL_ADDR>
<BILL_TO_ORG_ID>807737</BILL_TO_ORG_ID>
<SHIPPED_VIA>UPS</SHIPPED_VIA>
<DELIVERY_TERM>DDU</DELIVERY_TERM>
<TEXT_FILE_SEPARATOR></TEXT_FILE_SEPARATOR>
<DELIVERY_COUNT>4</DELIVERY_COUNT>
<HEADER_WAYBILL></HEADER_WAYBILL>
<LIST_G_LINES>
<G_LINES>
<DELIVERY_ID>2629769</DELIVERY_ID>
<ORDER_HEADER_ID>1431282</ORDER_HEADER_ID>
<ORDER_NUMBER>10004434</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-387</CUST_PO_NUMBER>
<ORDER_LINE_ID>4565737</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>26818</INVENTORY_ITEM_ID>
<PART_NUMBER>777459-23</PART_NUMBER>
<PART_DESC>SCC-AI04, 2-CHANNEL ISOLATED ANALOG INPUT</PART_DESC>
<PART_CUSTOM_DESC>SCC-AI04, Automatic Data Processing Plug-In Board</PART_CUSTOM_DESC>
<PLANNER_CODE>SCXIH-MPS</PLANNER_CODE>
<HTS_CODE>8471.80.9000</HTS_CODE>
<TARIC_CODE>8471.80.0000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>158</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>4</ORIG_SHIP_QTY>
<UNIT_PRICE>158</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>158</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>4</SHIP_QTY>
<EXTENDED_PRICE>632</EXTENDED_PRICE>
<UNIT_WEIGHT>.16</UNIT_WEIGHT>
<NET_WEIGHT>.64</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/01 NIC</WAYBILL>
<BREAKDOWN_COUNT>0</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE></BREAKDOWN_TYPE>
<BREAKDOWN_VALUE></BREAKDOWN_VALUE>
<COMPONENT></COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE></COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO></COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
<G_LINES>
<DELIVERY_ID>2629769</DELIVERY_ID>
<ORDER_HEADER_ID>1431282</ORDER_HEADER_ID>
<ORDER_NUMBER>10004434</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-387</CUST_PO_NUMBER>
<ORDER_LINE_ID>4579950</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>143949</INVENTORY_ITEM_ID>
<PART_NUMBER>779475-01</PART_NUMBER>
<PART_DESC>SCC-68 I/O CONNECTOR BLOCK WITH 4 SCC SIGNAL CONDITIONING MODULE SLOTS</PART_DESC>
<PART_CUSTOM_DESC>SCC-68, Screw Terminals</PART_CUSTOM_DESC>
<PLANNER_CODE>DAQH-MPS</PLANNER_CODE>
<HTS_CODE>8536.90.4000</HTS_CODE>
<TARIC_CODE>8536.90.1000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>144</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>10</ORIG_SHIP_QTY>
<UNIT_PRICE>144</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>144</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>10</SHIP_QTY>
<EXTENDED_PRICE>1440</EXTENDED_PRICE>
<UNIT_WEIGHT>1.06</UNIT_WEIGHT>
<NET_WEIGHT>10.6</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/01 NIC</WAYBILL>
<BREAKDOWN_COUNT>3</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>CD</COMPONENT>
<COMPONENT_DESC>Test1</COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>50</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2803.00.0050</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE>Test1</COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY>10</COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>Paper</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>20</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2839.90.0000</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>IP</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>1370</COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
<G_LINES>
<DELIVERY_ID>2629822</DELIVERY_ID>
<ORDER_HEADER_ID>1425429</ORDER_HEADER_ID>
<ORDER_NUMBER>10004365</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-372</CUST_PO_NUMBER>
<ORDER_LINE_ID>4579940</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>22643</INVENTORY_ITEM_ID>
<PART_NUMBER>777687-20</PART_NUMBER>
<PART_DESC>SCXI-1320 TEMPERATURE SENSOR TERMINAL BLOCK, CAST</PART_DESC>
<PART_CUSTOM_DESC>SCXI-1320, Screw Terminals</PART_CUSTOM_DESC>
<PLANNER_CODE>SCXIH-MPS</PLANNER_CODE>
<HTS_CODE>8536.90.4000</HTS_CODE>
<TARIC_CODE>8536.90.1000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>82</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>1</ORIG_SHIP_QTY>
<UNIT_PRICE>82</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>82</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>1</SHIP_QTY>
<EXTENDED_PRICE>82</EXTENDED_PRICE>
<UNIT_WEIGHT>.57</UNIT_WEIGHT>
<NET_WEIGHT>.57</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/02 NIC</WAYBILL>
<BREAKDOWN_COUNT>3</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>CD</COMPONENT>
<COMPONENT_DESC>Test1</COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>5</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2803.00.0050</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE>Test1</COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY>1</COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>Paper</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>2</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2839.90.0000</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>IP</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>75</COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
<G_LINES>
<DELIVERY_ID>2629822</DELIVERY_ID>
<ORDER_HEADER_ID>1427673</ORDER_HEADER_ID>
<ORDER_NUMBER>10004391</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-377</CUST_PO_NUMBER>
<ORDER_LINE_ID>4579948</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>143949</INVENTORY_ITEM_ID>
<PART_NUMBER>779475-01</PART_NUMBER>
<PART_DESC>SCC-68 I/O CONNECTOR BLOCK WITH 4 SCC SIGNAL CONDITIONING MODULE SLOTS</PART_DESC>
<PART_CUSTOM_DESC>SCC-68, Screw Terminals</PART_CUSTOM_DESC>
<PLANNER_CODE>DAQH-MPS</PLANNER_CODE>
<HTS_CODE>8536.90.4000</HTS_CODE>
<TARIC_CODE>8536.90.1000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>144</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>13</ORIG_SHIP_QTY>
<UNIT_PRICE>144</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>144</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>13</SHIP_QTY>
<EXTENDED_PRICE>1872</EXTENDED_PRICE>
<UNIT_WEIGHT>1.06</UNIT_WEIGHT>
<NET_WEIGHT>13.78</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/02 NIC</WAYBILL>
<BREAKDOWN_COUNT>3</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>CD</COMPONENT>
<COMPONENT_DESC>Test1</COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>65</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2803.00.0050</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE>Test1</COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY>13</COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>Paper</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>26</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2839.90.0000</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>IP</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>1781</COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
<G_LINES>
<DELIVERY_ID>2630021</DELIVERY_ID>
<ORDER_HEADER_ID>1429687</ORDER_HEADER_ID>
<ORDER_NUMBER>10004410</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-383</CUST_PO_NUMBER>
<ORDER_LINE_ID>4578220</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>61816</INVENTORY_ITEM_ID>
<PART_NUMBER>777687-14</PART_NUMBER>
<PART_DESC>SCXI-1314 FRONT MOUNTING TERMINAL BLOCK</PART_DESC>
<PART_CUSTOM_DESC>SCXI-1314, Screw Terminals</PART_CUSTOM_DESC>
<PLANNER_CODE>SCXIH-MPS</PLANNER_CODE>
<HTS_CODE>8536.90.4000</HTS_CODE>
<TARIC_CODE>8536.90.1000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>120</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>4</ORIG_SHIP_QTY>
<UNIT_PRICE>120</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>120</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>4</SHIP_QTY>
<EXTENDED_PRICE>480</EXTENDED_PRICE>
<UNIT_WEIGHT>.68</UNIT_WEIGHT>
<NET_WEIGHT>2.72</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/03 NIC</WAYBILL>
<BREAKDOWN_COUNT>3</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>CD</COMPONENT>
<COMPONENT_DESC>Test1</COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>20</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2803.00.0050</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE>Test1</COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY>4</COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>IP</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>452</COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>Paper</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>8</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2839.90.0000</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
<G_LINES>
<DELIVERY_ID>2630054</DELIVERY_ID>
<ORDER_HEADER_ID>1435114</ORDER_HEADER_ID>
<ORDER_NUMBER>10004463</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-396</CUST_PO_NUMBER>
<ORDER_LINE_ID>4580160</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>96909</INVENTORY_ITEM_ID>
<PART_NUMBER>778729-01</PART_NUMBER>
<PART_DESC>NI PCI-4474, 4 INPUTS, 24-BIT DYNAMIC SIGNAL ACQUISITION</PART_DESC>
<PART_CUSTOM_DESC>PCI-4474, Automatic Data Processing Plug-In Board</PART_CUSTOM_DESC>
<PLANNER_CODE>INSTRHMPS</PLANNER_CODE>
<HTS_CODE>8471.80.4000</HTS_CODE>
<TARIC_CODE>8471.80.0000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>960</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>4</ORIG_SHIP_QTY>
<UNIT_PRICE>960</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>960</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>4</SHIP_QTY>
<EXTENDED_PRICE>3840</EXTENDED_PRICE>
<UNIT_WEIGHT>.68</UNIT_WEIGHT>
<NET_WEIGHT>2.72</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/04 NIC</WAYBILL>
<BREAKDOWN_COUNT>0</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE></BREAKDOWN_TYPE>
<BREAKDOWN_VALUE></BREAKDOWN_VALUE>
<COMPONENT></COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE></COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO></COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
</LIST_G_LINES>
</G_HEADER>
</LIST_G_HEADER>
</NI_COMMERCIAL_INVOICE_XMLP>
I want my report for part number (which has multiple component) look like:
Part Number: 779475-01 Quantity: 23 Part Count:2 Breakdown Count:6
Component: CD Amount: 115
Component: IP Amount: 3151
Component: Paper Amount: 46
Any help or suggestion is appreciated
RK Shah
[email protected]I am using the latest 10.1.3.2.1 build 87.
The output that I see is :
Part Number: 777687-14 Quantity: 4 Part Count:1 Breakdown Count:3
Component: CD
Count: 4
Sum of Component Price: 20
Component: IP
Count: 0
Sum of Component Price: 452
Component: Paper
Count: 0
Sum of Component Price: 8
Part Number: 777687-20 Quantity: 1 Part Count:1 Breakdown Count:3
Component: CD
Count: 1
Sum of Component Price: 5
Component: Paper
Count: 0
Sum of Component Price: 2
Component: IP
Count: 0
Sum of Component Price: 75
Part Number: 779475-01 Quantity: 23 Part Count:2 Breakdown Count:3
Component: CD
Count: 23
Sum of Component Price: 115
Component: Paper
Count: 0
Sum of Component Price: 46
Component: IP
Count: 0
Sum of Component Price: 3151
and the XML data that I used is :
<?xml version="1.0"?>
<!-- Generated by Oracle Reports version 6.0.8.25.0 -->
<NI_COMMERCIAL_INVOICE_XMLP>
<LIST_G_HEADER>
<G_HEADER>
<COMM_INV_NUMBER>C/901000598</COMM_INV_NUMBER>
<COMM_INV_VERSION_NUMBER>1</COMM_INV_VERSION_NUMBER>
<SHIP_FROM_NAME>National Instruments Europe Corp.</SHIP_FROM_NAME>
<SHIP_FROM_ADDR>H-4031, Debrecen, Hatar ut 1/A</SHIP_FROM_ADDR>
<SHIP_FROM_CITY></SHIP_FROM_CITY>
<SHIP_FROM_STATE></SHIP_FROM_STATE>
<SHIP_FROM_POSTAL_CODE></SHIP_FROM_POSTAL_CODE>
<SHIP_FROM_COUNTRY>Hungary</SHIP_FROM_COUNTRY>
<SHIP_TO_NAME>National Instruments Corporation (NIEC)</SHIP_TO_NAME>
<FORMATTED_SHIP_TO_ADDR>11500 N Mopac Expwy
Austin, TX 78759-3504
United States</FORMATTED_SHIP_TO_ADDR>
<SHIP_TO_ADDR1>11500 N Mopac Expwy</SHIP_TO_ADDR1>
<SHIP_TO_ADDR2></SHIP_TO_ADDR2>
<SHIP_TO_ADDR3></SHIP_TO_ADDR3>
<SHIP_TO_ADDR4></SHIP_TO_ADDR4>
<SHIP_TO_CITY>Austin</SHIP_TO_CITY>
<SHIP_TO_STATE>TX </SHIP_TO_STATE>
<SHIP_TO_POSTAL_CODE>78759-3504</SHIP_TO_POSTAL_CODE>
<SHIP_TO_COUNTRY>US</SHIP_TO_COUNTRY>
<SHIP_TO_EMAIL_ADDR></SHIP_TO_EMAIL_ADDR>
<BILL_TO_ORG_ID>807737</BILL_TO_ORG_ID>
<SHIPPED_VIA>UPS</SHIPPED_VIA>
<DELIVERY_TERM>DDU</DELIVERY_TERM>
<TEXT_FILE_SEPARATOR></TEXT_FILE_SEPARATOR>
<DELIVERY_COUNT>4</DELIVERY_COUNT>
<HEADER_WAYBILL></HEADER_WAYBILL>
<LIST_G_LINES>
<G_LINES>
<DELIVERY_ID>2629769</DELIVERY_ID>
<ORDER_HEADER_ID>1431282</ORDER_HEADER_ID>
<ORDER_NUMBER>10004434</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-387</CUST_PO_NUMBER>
<ORDER_LINE_ID>4565737</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>26818</INVENTORY_ITEM_ID>
<PART_NUMBER>777459-23</PART_NUMBER>
<PART_DESC>SCC-AI04, 2-CHANNEL ISOLATED ANALOG INPUT</PART_DESC>
<PART_CUSTOM_DESC>SCC-AI04, Automatic Data Processing Plug-In Board</PART_CUSTOM_DESC>
<PLANNER_CODE>SCXIH-MPS</PLANNER_CODE>
<HTS_CODE>8471.80.9000</HTS_CODE>
<TARIC_CODE>8471.80.0000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>158</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>4</ORIG_SHIP_QTY>
<UNIT_PRICE>158</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>158</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>4</SHIP_QTY>
<EXTENDED_PRICE>632</EXTENDED_PRICE>
<UNIT_WEIGHT>.16</UNIT_WEIGHT>
<NET_WEIGHT>.64</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/01 NIC</WAYBILL>
<BREAKDOWN_COUNT>0</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE></BREAKDOWN_TYPE>
<BREAKDOWN_VALUE></BREAKDOWN_VALUE>
<COMPONENT></COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE></COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO></COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
<G_LINES>
<DELIVERY_ID>2629769</DELIVERY_ID>
<ORDER_HEADER_ID>1431282</ORDER_HEADER_ID>
<ORDER_NUMBER>10004434</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-387</CUST_PO_NUMBER>
<ORDER_LINE_ID>4579950</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>143949</INVENTORY_ITEM_ID>
<PART_NUMBER>779475-01</PART_NUMBER>
<PART_DESC>SCC-68 I/O CONNECTOR BLOCK WITH 4 SCC SIGNAL CONDITIONING MODULE SLOTS</PART_DESC>
<PART_CUSTOM_DESC>SCC-68, Screw Terminals</PART_CUSTOM_DESC>
<PLANNER_CODE>DAQH-MPS</PLANNER_CODE>
<HTS_CODE>8536.90.4000</HTS_CODE>
<TARIC_CODE>8536.90.1000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>144</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>10</ORIG_SHIP_QTY>
<UNIT_PRICE>144</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>144</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>10</SHIP_QTY>
<EXTENDED_PRICE>1440</EXTENDED_PRICE>
<UNIT_WEIGHT>1.06</UNIT_WEIGHT>
<NET_WEIGHT>10.6</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/01 NIC</WAYBILL>
<BREAKDOWN_COUNT>3</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>CD</COMPONENT>
<COMPONENT_DESC>Test1</COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>50</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2803.00.0050</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE>Test1</COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY>10</COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>Paper</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>20</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2839.90.0000</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>IP</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>1370</COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
<G_LINES>
<DELIVERY_ID>2629822</DELIVERY_ID>
<ORDER_HEADER_ID>1425429</ORDER_HEADER_ID>
<ORDER_NUMBER>10004365</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-372</CUST_PO_NUMBER>
<ORDER_LINE_ID>4579940</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>22643</INVENTORY_ITEM_ID>
<PART_NUMBER>777687-20</PART_NUMBER>
<PART_DESC>SCXI-1320 TEMPERATURE SENSOR TERMINAL BLOCK, CAST</PART_DESC>
<PART_CUSTOM_DESC>SCXI-1320, Screw Terminals</PART_CUSTOM_DESC>
<PLANNER_CODE>SCXIH-MPS</PLANNER_CODE>
<HTS_CODE>8536.90.4000</HTS_CODE>
<TARIC_CODE>8536.90.1000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>82</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>1</ORIG_SHIP_QTY>
<UNIT_PRICE>82</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>82</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>1</SHIP_QTY>
<EXTENDED_PRICE>82</EXTENDED_PRICE>
<UNIT_WEIGHT>.57</UNIT_WEIGHT>
<NET_WEIGHT>.57</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/02 NIC</WAYBILL>
<BREAKDOWN_COUNT>3</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>CD</COMPONENT>
<COMPONENT_DESC>Test1</COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>5</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2803.00.0050</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE>Test1</COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY>1</COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>Paper</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>2</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2839.90.0000</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>IP</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>75</COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
<G_LINES>
<DELIVERY_ID>2629822</DELIVERY_ID>
<ORDER_HEADER_ID>1427673</ORDER_HEADER_ID>
<ORDER_NUMBER>10004391</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-377</CUST_PO_NUMBER>
<ORDER_LINE_ID>4579948</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>143949</INVENTORY_ITEM_ID>
<PART_NUMBER>779475-01</PART_NUMBER>
<PART_DESC>SCC-68 I/O CONNECTOR BLOCK WITH 4 SCC SIGNAL CONDITIONING MODULE SLOTS</PART_DESC>
<PART_CUSTOM_DESC>SCC-68, Screw Terminals</PART_CUSTOM_DESC>
<PLANNER_CODE>DAQH-MPS</PLANNER_CODE>
<HTS_CODE>8536.90.4000</HTS_CODE>
<TARIC_CODE>8536.90.1000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>144</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>13</ORIG_SHIP_QTY>
<UNIT_PRICE>144</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>144</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>13</SHIP_QTY>
<EXTENDED_PRICE>1872</EXTENDED_PRICE>
<UNIT_WEIGHT>1.06</UNIT_WEIGHT>
<NET_WEIGHT>13.78</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/02 NIC</WAYBILL>
<BREAKDOWN_COUNT>3</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>CD</COMPONENT>
<COMPONENT_DESC>Test1</COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>65</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2803.00.0050</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE>Test1</COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY>13</COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>Paper</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>26</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2839.90.0000</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>IP</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>1781</COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
<G_LINES>
<DELIVERY_ID>2630021</DELIVERY_ID>
<ORDER_HEADER_ID>1429687</ORDER_HEADER_ID>
<ORDER_NUMBER>10004410</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-383</CUST_PO_NUMBER>
<ORDER_LINE_ID>4578220</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>61816</INVENTORY_ITEM_ID>
<PART_NUMBER>777687-14</PART_NUMBER>
<PART_DESC>SCXI-1314 FRONT MOUNTING TERMINAL BLOCK</PART_DESC>
<PART_CUSTOM_DESC>SCXI-1314, Screw Terminals</PART_CUSTOM_DESC>
<PLANNER_CODE>SCXIH-MPS</PLANNER_CODE>
<HTS_CODE>8536.90.4000</HTS_CODE>
<TARIC_CODE>8536.90.1000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>120</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>4</ORIG_SHIP_QTY>
<UNIT_PRICE>120</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>120</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>4</SHIP_QTY>
<EXTENDED_PRICE>480</EXTENDED_PRICE>
<UNIT_WEIGHT>.68</UNIT_WEIGHT>
<NET_WEIGHT>2.72</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/03 NIC</WAYBILL>
<BREAKDOWN_COUNT>3</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>CD</COMPONENT>
<COMPONENT_DESC>Test1</COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>20</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2803.00.0050</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE>Test1</COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY>4</COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>IP</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>452</COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE>HTS CODE</BREAKDOWN_TYPE>
<BREAKDOWN_VALUE>8536.90.4000</BREAKDOWN_VALUE>
<COMPONENT>Paper</COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE>8</COMPONENT_PRICE>
<COMPONENT_HTS_CODE>2839.90.0000</COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO>HU</COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
<G_LINES>
<DELIVERY_ID>2630054</DELIVERY_ID>
<ORDER_HEADER_ID>1435114</ORDER_HEADER_ID>
<ORDER_NUMBER>10004463</ORDER_NUMBER>
<CUST_PO_NUMBER>310986-396</CUST_PO_NUMBER>
<ORDER_LINE_ID>4580160</ORDER_LINE_ID>
<INVENTORY_ITEM_ID>96909</INVENTORY_ITEM_ID>
<PART_NUMBER>778729-01</PART_NUMBER>
<PART_DESC>NI PCI-4474, 4 INPUTS, 24-BIT DYNAMIC SIGNAL ACQUISITION</PART_DESC>
<PART_CUSTOM_DESC>PCI-4474, Automatic Data Processing Plug-In Board</PART_CUSTOM_DESC>
<PLANNER_CODE>INSTRHMPS</PLANNER_CODE>
<HTS_CODE>8471.80.4000</HTS_CODE>
<TARIC_CODE>8471.80.0000</TARIC_CODE>
<COUNTRY_OF_ORIGIN>HU</COUNTRY_OF_ORIGIN>
<ORDER_CURRENCY_CODE>USD</ORDER_CURRENCY_CODE>
<ORIG_UNIT_PRICE>960</ORIG_UNIT_PRICE>
<ORIG_SHIP_QTY>4</ORIG_SHIP_QTY>
<UNIT_PRICE>960</UNIT_PRICE>
<PRICE_CALC_STEP_NUMBER>100</PRICE_CALC_STEP_NUMBER>
<PRICE_CALC_CURRENCY_CODE>USD</PRICE_CALC_CURRENCY_CODE>
<PRICE_CALC_UNIT_PRICE>960</PRICE_CALC_UNIT_PRICE>
<PRICE_CALC_CONV_RATE>1</PRICE_CALC_CONV_RATE>
<SHIP_QTY>4</SHIP_QTY>
<EXTENDED_PRICE>3840</EXTENDED_PRICE>
<UNIT_WEIGHT>.68</UNIT_WEIGHT>
<NET_WEIGHT>2.72</NET_WEIGHT>
<ACQ_SOURCE_CODE></ACQ_SOURCE_CODE>
<ACQ_ORDER_NUMBER></ACQ_ORDER_NUMBER>
<ACQ_SOURCE_ORDER_NUMBER></ACQ_SOURCE_ORDER_NUMBER>
<ACQ_SELLING_PRICE>0</ACQ_SELLING_PRICE>
<SUBINVENTORY>NIEC Stage</SUBINVENTORY>
<SHIP_TO_SITE_USE_ID>807736</SHIP_TO_SITE_USE_ID>
<FREIGHT_COST>0</FREIGHT_COST>
<PAYMENT_TERMS>NIH InterCo</PAYMENT_TERMS>
<WAYBILL>901000598/04 NIC</WAYBILL>
<BREAKDOWN_COUNT>0</BREAKDOWN_COUNT>
<LIST_G_BREAKDOWN>
<G_BREAKDOWN>
<BREAKDOWN_TYPE></BREAKDOWN_TYPE>
<BREAKDOWN_VALUE></BREAKDOWN_VALUE>
<COMPONENT></COMPONENT>
<COMPONENT_DESC></COMPONENT_DESC>
<COMPONENT_CUSTOM_DESC></COMPONENT_CUSTOM_DESC>
<COMPONENT_PRICE></COMPONENT_PRICE>
<COMPONENT_HTS_CODE></COMPONENT_HTS_CODE>
<COMPONENT_TARIC_CODE></COMPONENT_TARIC_CODE>
<COMPONENT_COO></COMPONENT_COO>
<COMPONENT_QTY></COMPONENT_QTY>
</G_BREAKDOWN>
</LIST_G_BREAKDOWN>
</G_LINES>
</LIST_G_LINES>
</G_HEADER>
</LIST_G_HEADER>
</NI_COMMERCIAL_INVOICE_XMLP> -
Sales - Quoting Functionality - XML Publisher and XSL.
Hi ,
We have changed output in Quoting to use XML Publisher instead of Reports Server.
How can we view the XML tags to create the XSL file?
Its possible to see XML output from PO's , SOA's etc when printed vis Concurrent Mgr and Oracle Forms but the raw XML is not available when using in Sales and Printing a Quote ( uses sample xsl in XML Publisher at the moment...Am formatting this.. but have no raw xml).
Any ideas?
Cheers
StephenI know what I can do in RTF and maybe it´s enough:
1. Ensure you are using both tabs of the help text, you can start in Status Bar and continue with Help Key.
2. You can also use multiple fields one after another.
3. If you fill all of that and need more space I would consider moving the function out into its own XSL template and register it as a sub template and reference it from your main template. This is especially useful if you are going to need the same function across multiple templates.
My problem was why I can´t use XSL-FO - XML in XMLSPY, have´nt anybody tried to go out of the WORD-RTF and code som XSL? Maybe it´s not possible and I have to use WORD-RTF.
/Daniel -
Crosstab report with XML Publisher without aggreate function
Hi Gurus,
I have query that returning the task schedule of the man power as below
Source Date Week Day Customer Activity Service
Pat
16-Oct-14
42
T
C1
A1
S1
Pat
17-Oct-14
42
F
C1
A1
S1
Pat
18-Oct-14
42
S
Pat
19-Oct-14
42
S
Pat
20-Oct-14
43
M
Pat
21-Oct-14
43
T
Pat
22-Oct-14
43
W
Pat
23-Oct-14
43
T
C2
S2
Pat
24-Oct-14
43
F
Riley
16-Oct-14
42
T
C3
A1
S3
Riley
17-Oct-14
42
F
Riley
18-Oct-14
42
S
Riley
19-Oct-14
42
S
C4
A1
S4
Riley
20-Oct-14
43
M
Riley
21-Oct-14
43
T
Riley
22-Oct-14
43
W
Riley
23-Oct-14
43
T
Riley
24-Oct-14
43
F
and want to format the output as weekly calendar as below (the week must be dynamic depends on number of dates return) using XML Publisher 10.1.3.3.3
Week-42 Week-43
Source Date Day Customers Activity Service Code Date Day Customers Activity Service Code
Pat 16-Oct-14 T C1 A1 S1 20-Oct-14 M
17-Oct-14 F C1 A1 S1 21-Oct-14 T
18-Oct-14 S 22-Oct-14 W
19-Oct-14 S 23-Oct-14 T C2 S2
24-Oct-14 F
Riley 16-Oct-14 T C3 A1 S3 20-Oct-14 M
17-Oct-14 F 21-Oct-14 T
18-Oct-14 S 22-Oct-14 W
19-Oct-14 S C4 A1 S4 23-Oct-14 T
24-Oct-14 F
Is it possible to do that?
Regards,
FendyYes, I got it working.
Follow the instructions as mentioned in the User Guide, it will workout well.
1. Create a concurrent program with "XDODTEXE" as the Executable.
2. Create the data definition and associate a data template (this is with your sql) to it and and link the above concurrent program with this data definition.
Let me know if you need more details. Good thing about this is that you do not have to move any files on to your unix server (like in the case of oracle reports). -
How Can I apply a RTF Function on a variable in RTF Template in XML Publisher Report
Hi Everyone,
I am developing a RTF Template of XML Publisher Report, I have a variable lv_counter which I can declare using below syntax
<?xdoxslt: set_variable($_XDOCTX, 'lv_counter',0)?>
I can access this variable in the template as <?xdoxslt: get_variable($_XDOCTX,'lv_counter')?>
My need is to print the variable in words in the RTF Template. I am using <?xdofx: to_check_number(xdoxslt: get_variable($_XDOCTX,'lv_counter'))?>
But this is not working. any help will be appreciated thanks in advance
The XML Publisher Desktop version which I am using is 10.1.3.3.0
Please let me know where I can post this question, if this is not the appropriate discussion forum.
Thanks in Advance.Hi,
Can you elaborate your requirement little bit clear with some example like what is your expected output.
And you can post you BI related question in the BI publisher forum
https://forums.oracle.com/community/developer/english/business_intelligence/business_intelligence_foundation/bi_publisher/content?filterID=contentstatus[published]~objecttype~objecttype[thread]
Regards
Sri -
Dear Members :
I have following template:
G_1
item1, item2 ...
G-2
item5, ...
G_3
item9, ...
G_3
G_2
sum(item5)
G_1
Getting 0 in field placeholder sum(item5), though item5 has value. If I put the same within G_2 group, getting the correct value. Why can't it sum outside of G_2 group ?
I am on XML Publisher ver 4.5 on application server (Oracle 11.5.10).
Also if I try to declare a variable after group G_1, with :
<?xdoxslt:set_variable($_XDOCTX, 'var', 0)?>
I get the following error in log of Concurrent Program :
XML Publisher: Version : 11.5.0 - Development
Copyright (c) 1979, 1999, Oracle Corporation. All rights reserved.
XDOREPPB module: XML Report Publisher
Current system time is 31-JAN-2011 00:51:47
XML Report Publisher 4.5
Updating request description
Waiting for XML request
Retrieving XML request information
Preparing parameters
Process template
--XDOException
oracle.xml.parser.v2.XPathException: Variable not defined: '_XDOCTX'.
at oracle.xml.parser.v2.XPathVarReference.getValue(XPathVarReference.java:58)
at oracle.xml.parser.v2.XPathExtFunction.getValue(XPathExtFunction.java:131)
Could you please tell where I am going wrong ? Is it that the XML Publisher version doesn't support this ?
Thanks.
Atanu
Edited by: user11184124 on Jan 30, 2011 11:14 AMoracle.xml.parser.v2.XPathException: Variable not defined: '_XDOCTX'.
at oracle.xml.parser.v2.XPathVarReference.getValue(XPathVarReference.java:58)
at oracle.xml.parser.v2.XPathExtFunction.getValue(XPathExtFunction.java:131)
.................................Is this a variable you have defined in your code?
Thanks,
Hussein -
XML Publisher Multiple loops page break
In my XML Publisher template i am haveing nested loops. The tag <?split-by-page-break:?> is working fine for all but the last iteration. Is there a tag for page break which work always irrespective of the iteration.
I cannot use ctrl+enter in the template as the whole page is a table whose headers are repeating and on inserting the ctrl+enter the table break.
Is there any other way to achieve the functionality of ctrl+enter through the xml tag.Hi,
Yes, i was abe to do this, i moved the Customer name filed above the Invoice group and added extra conditin in the rtf.
Regards,
RR -
XML PUBLISHER report in Excel out put problem
Hi Experts,
I have developed one XML report which output type is EXCEL in Oracle Application.
I am getting some -ve value in the report so I need to do the trailing sign
Menace for example I got a value -8645 I need to display the value like (8645).
This functionality is working in PDF output but in EXCEL out put it is not working.
Could any body please help me on this..
Its Urgent .
Thanks in Advance.Check this metalink notes, did you got any error..?
Note: 364547.1 - Troubleshooting Oracle XML Publisher For The Oracle E-Business Suite
https://metalink.oracle.com/metalink/plsql/ml2_documents.showDocument?p_database_id=NOT&p_id=364547.1
Note: 359875.1 - Cannot View Xml Publisher Report Output In Excel Format
Note: 358296.1 - How To Produce Requests In Formats Of HTML, RTF, and Excel From XML Publisher
Note: 850685.1 - Wrong Output Format In Xml Publisher Output
Note: 727031.1 - XML Publisher Requests Always Get Defaulted to Output Format as PDF Whatever the Template Type is Set To
Note: 337343.1 - Unable to View Excel Output File Created by XML Publisher
Note: 401328.1 - Default Layout Format for XML Publisher Concurrent Request Is Always PDF
Re: XML Publisher Server on EBS 11.5.10.2 -
XML Publisher report giving XML tag output
Dear All,
Please note that we need to convert the standard report 'Bill of Material Comparison Report' to XML Publisher report.
But we were not able to get the desired PDF output instead it shows only XML output.
This report is not a direct concurrent program call to rdf, this concurrent program is triggered from a function.
How can we overcome this issue..,
Please update,
Many thanks...,Hi Kiran,
Please find the below info:
Could you please confirm whether you have made the standard program's executable as 'XDODTEXE', and created a data definition with the rdf shorname and Data templte with the template defined.
-- Done
Could you also provide how your calling the report and when the request submitted are u able to see the template name on the submitted request ?
-- The report is called through the application (in Bill of materials through a Form Function) When we select the comparison, it will display a comparison form, where we need to select the appropriate parameters and a button called 'Report' if clicked, it will fire the 'Bill of Material Comparison Report' concurrent program
But after the concurrent program submission, we cannot see any template been attached to the submitted conc. pprog. but the template is been already attached to the concurrent program through the XML Publisher Administrator
Many thanks.... -
XML Publisher report to view as a self service page in EBS R12
Hi All,
I would like to show my XML publisher report as a self service page. What are the different methods in which i can show these reports. I would like to just click the function of the responsibility and see the report as a page.
Your suggestions would be appreciable. Thanks in advance.
Regards,
BorisHi All,
I would like to show my XML publisher report as a self service page. What are the different methods in which i can show these reports. I would like to just click the function of the responsibility and see the report as a page.
Your suggestions would be appreciable. Thanks in advance.
Regards,
Boris -
I have a xml publisher report which list job names. After submitting concurrent program, I am getting below error
A semi colon character was expected. Error processing resource
some of the Jobs have special character '&'. below is code
CREATE OR REPLACE PACKAGE BODY XML_RPT AS
FUNCTION XML_TAG (p_tag IN VARCHAR2, p_data IN VARCHAR2) RETURN VARCHAR2 IS
l_ret_str VARCHAR2(5000);
BEGIN
l_ret_str := '<'||p_tag||'>'||p_data||'</'||p_tag||'>';
RETURN l_ret_str;
END XML_TAG;
PROCEDURE JOBS(errbuf OUT VARCHAR2,
retcode OUT NUMBER) IS
CURSOR inv_Cur IS
select name
from per_jobs pv;
xmldata varchar2(1000);
l_sqlstr varchar2(1000);
l_seqnum varchar2(3);
l_job_name varchar2(100);
BEGIN
xmldata := '<?xml version="1.0" encoding="UTF-8"?>';
xmldata :=xmldata|| '<JOB>';
xmldata := xmldata||' <LIST_JOB>';
fnd_file.put_line(fnd_file.output,xmldata);
FOR rpt_rec IN inv_Cur LOOP
xmldata := '<JOB_REC>';
l_job_name := replace(rpt_rec.JOB_NAME,'&','&');
xmldata := xmldata || XXMCG_XML_TAG('JOB_NAME',L_JOB_NAME);
xmldata :=xmldata|| '</JOB_REC>';
fnd_file.put_line(fnd_file.output,xmldata);
END LOOP;
xmldata := '</LIST_JOB>';
xmldata := xmldata||'</JOB>';
fnd_file.put_line(fnd_file.output,xmldata);
EXCEPTION
WHEN OTHERS THEN
fnd_file.put_line(fnd_file.log,substr(SQLERRM,1,500));
END JOBS;
END XML_RPT;I resolved the problem. I have to put ; in the special character.
-
IN Operator in xml publisher RTF
Hi,
I am working on XML Publisher reports ( r12 EBS, Database 10g). Is there any way i can use 'IN' operator in RTF.
I have following requirement.
my rtf:
<?count?> --paramter
name1 name2 name3 name4
<?for each-group?> <?name1?> <?name2?> <?name3?> <?name4?> <?end for-each?>
if i enter count 1, i want to display 'name1'
if i enter count 2, i want to display 'name1 and name2'
if i enter count 3, i want to display 'first 3 names'
if enter count 3, i want to display all names.
Could somebody help me how to achieve this. Can i use 'IN' Operator in RTF.
Thanks in advance.You can use the 'contains' function. Check out the following:
Re: Using Wild Card % in the IF condition of RTF templates
Re: Syntax for IN / NOT IN Commands
Thanks,
Bipuser -
Page Break In XML Publisher RTF Templates Are Not Working
Please refer to the Metalink Doc below:
Subject: Page Break In XML Publisher RTF Templates Are Not Working.
Doc ID: 559111.1
Type: PROBLEM
Modified Date: 24-MAR-2008
Status: MODERATED
In this Document
Symptoms
Cause
Solution
References
This document is being delivered to you via Oracle Support's Rapid Visibility (RaV) process, and therefore has not been subject to an independent technical review.
Applies to:
Oracle XML Publisher - Version: 5.6.3
This problem can occur on any platform.
Symptoms
Using XML Publisher version 5.6.3 in 11.5.10.
Find <?split-by-page-break:?> syntax is ignored.
EXPECTED BEHAVIOR
Expect page breaks to occur at point set by "split-by-page-break:" code.
STEPS
The issue can be reproduced at will with the following steps:
1. Create a template.
2. Call split-by-page-break: inside a loop.
3. Output is not formatted correctly, page break call is ignored,
Cause
Unpublished BUG 5011628 SPLIT-BY-PAGE-BREAK NOT WORKING IF ADDED SORT WITHIN DYNAMIC GROUP
Unpublished BUG 5011628 matches the client issue as it is a call to split-by-page-break inside a loop.
Fix is in ScalableStringList.java version 115.4.
This is delivered in <Bug 6165466> XDOFX:CHR(N) FUNCTION FAILING.
Solution
To implement the solution, please execute the following steps:
1. Apply Patch 6165466 when it is released.
2. Test your report.
References
Bug 6165466 - XDOFX:CHR(N) FUNCTION FAILING
Keywords
XML~PUBLISHER; LOOP; DYNAMIC~GROUP; PAGE~BREAK;
Help us improve our service. Please email us your comments for this document. .Hi JDev,
Check this out:
http://oracle.anilpassi.com/xml-publisher-developing-reports-printed-on-pre-printed-stationary-2.html
Hope this might help.
Thanks -
Copy Concurrent Program - XML Publisher Report
I am running a xml publisher report and it is working fine when i submit directly, but when i use copy function to copy a concurrent program the template is not defaulted and program completes without an error, but when i try to view the output i am getting "Unable to find the published output for this request" error.
Hi user;
Please check this and this
Hope it helps
Regard
Helios
Maybe you are looking for
-
How do I retrieve the Adobe Pro License key/# so I can reinstall on my computer. I had to have the hard drive replaced due to failure and don't have the necessary information to reinstall Adobe Pro.
-
The light on my charger doesn't work
So the light on my charger cord no longer lights up at all. it'll momentarily stay on when i plug it in then i goes out - i know it is charging but idk what is causing the light to dim. is it a comp issue or a charger issue. should i take them in to
-
I can no longer upload files by draging and droping from windows explorer. Help!
Previously if had to upload a file i used to simply drag and drop that file from my pc to the website open in mozilla but can no longer able to do that. Now i have browse the file. its lengthy. Please help...
-
Sap Query Web Reporting - Issues with accents
Hi, We was using Web Reporting for Sap Querys, throw this tool we can generate automatically web reports. When we go to generated web report, selection screen show us character � instead accent letters. In addition to this, generated web repor
-
Am stuck in the US store. How do I switch to Canada in order to download apps?
Am stuck in the US store and can 't download aps until I switch to Canada store? How do I get it to switch?