Pass parameter to report paramater form from a form

I defined parameter in a form. I am trying to pass the parameters to a report's parameter form. Is there any way to accomplish this?
Thank you!

Maybe this example will help. This can be added in a when button pressed event to run the report.
DECLARE
pl_id ParamList;
subheader varchar2(1000);
BEGIN
** Check to see if the 'tmpdata' parameter list exists.
pl_id := Get_Parameter_List('tmpdata');
** If it does, then delete it before we create it again in
** case it contains parameters that are not useful for our
** purposes here.
IF NOT Id_Null(pl_id) THEN
Destroy_Parameter_List( pl_id );
END IF;
** Create the 'tmpdata' parameter list afresh.
pl_id := Create_Parameter_List('tmpdata');
** Add 1 data parameters to this parameter list
*/ -- subheader is a parameter created in Oracle Reports
subheader := :variable.txt_message_yes;
Add_Parameter(pl_id,'SUBTITLE',TEXT_PARAMETER,subheader );
**Pass a Parameter into PARAMFORM so that a parameter dialog will not appear
**for the parameters being passing in.
Add_Parameter(pl_id, 'PARAMFORM', TEXT_PARAMETER, 'NO');
** Run the report synchronously, passing the parameter list
*/ -- ABC is the report name
Run_Product(REPORTS, 'ABC', SYNCHRONOUS, RUNTIME, FILESYSTEM, pl_id, NULL);
END;
null

Similar Messages

  • How do I pass parameter to different portlet regions from another page?

    How do I pass parameter to different portlet regions from
    another page?
    I have a page that with two regions. Each region has a report
    that uses the same information to generate its report.
    Individually running the reports, I can use p_arg_names and
    p_arg_values to get what I want. However, when I run the page
    that has both portlets, my .show is gone and I cannot get it to
    use the p_arg_names, etc. Do you have any idea how to overcome
    this? Thanks for any help.

    How do I pass parameter to different portlet regions from
    another page?
    I have a page that with two regions. Each region has a report
    that uses the same information to generate its report.
    Individually running the reports, I can use p_arg_names and
    p_arg_values to get what I want. However, when I run the page
    that has both portlets, my .show is gone and I cannot get it to
    use the p_arg_names, etc. Do you have any idea how to overcome
    this? Thanks for any help.

  • Passing parameter to report title

    I am working with drill down report. My master ( Source ) report has
    Emp #, Emp Name, Address columns.
    I have prompt on Emp Name column. My second (target) has other employee details and report title is “ Individual Detail report for Employee” but my user is asking they want to display report name with employee name .( passing parameter to report title) . I mean in source report if I click on “Roy Rine” target report should display with following title
    “Individual Detail report for Roy Rine”
    Can I do this one with OBIEE? Please help me.
    Thanks for your time

    Its working but it is repeating names . i mean i have 4 people hvae name "Roy Jermon" . if i click on this column
    report is displaying ' INDIVIDUAL REPORT FOR ROY JERMON ROY JERMON ROY JERMON ROY JERMON"
    is ther any way we can control for only one time even if we have mutiple values.
    i am really appriciate for your time.

  • Query a second form from another form by passing value

    Hi,
    I have two forms. I am trying to query a second form from another form. I have managed to display the query results in the second form by passing value from the first form. I did it according to the details in the Oracle 9ias Portal Technical FAQ html file.
    It works fine when there is already a row in the first form. When I insert a new row in the first form and query the second form which has key from the first form, there is no matching rows displayed which is correct but detail action mode is 'NONE' for all detail rows.
    According to the FAQ, it says the following:-
    "When the called form is started, it executes a query with the supplied condition (in this case, "where deptno=10"). If the query is successful, the matching rows are displayed in Update mode. If no matching rows are found, the form starts in Insert mode."
    It does not happen for me. I get NONE mode for no matching rows. Is this a BUG ? I am working on Portal version 3.0.9.8.0.
    Is there something wrong in the code I wrote ? I would like to have all the detail mode as Insert.
    Here is the following code I wrote on SUCCESSFUL SUBMISSION OF THE FORM.
    declare
    my_url varchar2(1000);
    v_deptno number;
    begin
    v_deptno := p_session.get_value_as_NUMBER(p_block_name => 'DEFAULT', p_attribute_name => 'A_DEPTNO');
    my_url := 'PORTAL30.wwa_app_module.link?p_arg_names=_moduleid&p_arg_values=1268491962&p_arg_names=_show_header&p_arg_values=YES&p_arg_names=deptno&p_arg_values='||LTRIM(TO_CHAR(v_deptno))||'&p_arg_names=_deptno_cond&p_arg_values=%3D';
    go(my_url);
    end;

    Hi,
    The behaviour is OK as in the MD form there are two states "Save" and "Query and Save" and when the form is in "Query and Save" mode that means you can use it for both Query aswell as Save which is decided by your "Master action" if that is None it is used for Query , for Insert you will have to select Insert ,this is the Insert Mode behavior.
    If you open a new MD form that is also in the "Query and Save" the same behaviour will be there.
    Hope this answers your query.
    rahul

  • Error while calling a form from another form's menu item

    I created a main form and menu module for this form.
    I am calling another form from main form menu item.
    i moved both the forms and menu and compiled them.
    But, when i run this form i am getting an error saying
    FRM 92100: Your connection to the server was interrupted
    This may be the result of a network error, or a failure on the server.
    You will need to establish your session.
    I set the seperateframe = true
    networkentries = 30
    But still getting the same error.
    Is there any parameter that i am missing.
    I will greatly appreciate if anybody can direct me to the solution.
    Thank you.
    Navya.

    Hi guest,
    the data definition is:
    DATA: XVBKD LIKE VBKDVB OCCURS 0 WITH HEADER LINE.
    the assignment:
    XVBKD-PRSDT = likp-erdat.
    Thanks,
    Hagit

  • What are the 3 ways to call a form from another form?

    What are the 3 ways to call a form from another form?
    What is the command to call a report from within a form?
    How do you attach a menu to a form?

    Hi,
    1. Should be new_form, call_form and open_form
    2. The command is run_product
    3. There is a property 'Menu Module' in form, just change it to your menu file name
    Regards,
    George
    Can anyone help me with the following questions...
    What are the 3 ways to call a form from another form?
    What is the command to call a report from within a form?
    How do you attach a menu to a form?
    Thanks for your time..
    Madhu

  • Frm-92101 happens when I open a form from another form and close it.

    Frm-92101 happens when I open a form from another form, check something, show a message to the user and exit the form to the previous form.
    Forms version: 10.1.2.0.2. Java: 1.6.0_23. Browser: IE6
    When I put before the "EXIT_FORM" two messages, everything is fine and the second form is closed and I repeat to the first form just as I wanted.
    In forms 9.0 it didn't happen.
    Does it have a connection with the fact I use JRE instead of JInitiator?
    Thank you.

    >
    There are numerous causes of the FRM-92101 error. I recommend you start your investigation by tracing your Forms session so you can see what your form is doing when the error occurs. Check out My Oracle Support document How to Use Forms Trace with Forms [ID 209372.1] for information on how to enable the trace. Also, take a look at My Oracle Support document Known Causes of FRM-92101 Error In Forms [ID 604633.1].
    Hope this helps,
    Craig
    >
    I have just found that there is a "Synchronize" command in one of the main attached libraries, and when I comment that command the application works well. But I don't want to comment it because it's a great library and I assume it has a part in the system.
    I have discovered that in the new Forms' help, the fact that the System.Current_Item mustn't be null so the command "Synchronize" will work, is mentioned. In the old Forms' help, that fact is not mentioned.
    So I tried to put it inside a condition that checks if the current item is not null, but the compiler doesn't recognize the "current_item". I don't know why. Because it's a library? So how can I check this? I can sent it as a parameter, but I don't want. Do you know something about it? Thank you.

  • How to access objects in the Child Form from Parent form.

    I have a requirement in which I have to first open a Child Form from a Parent Form. Then I want to access objects in the Child Form from Parent form. For example, I want to insert a record into a block present in Child Form by executing statements from a trigger present in Parent Form.
    I cannot use object groups since I cannot write code into Child Form to first create object groups into Child Form.
    I have tried to achieved it using the following (working of my testcase) :
    1) Created two new Forms TESTFORM1.fmb (parent) and TESTFORM2.fmb (child).
    2) Created a block named BLK1 manually in TESTFORM1.
    3) Created two items in BLK1:
    1.PJC1 which is a text item.
    2.OPEN which is a push button.
    4) Created a new block using data block wizard for a table EMPLOYEE_S1. Created items corresponding to all columns present in EMPLOYEE_S1 table.
    5) In WHEN-NEW-FORM-INSTANCE trigger of TESTFORM1 set the first navigation block to BLK1. In BLK1 first navigable item is PJC1.
    6) In WHEN-NEW-ITEM-INSTANCE of PJC1, code has been written to automatically execute the WHEN-BUTTON-PRESSED trigger for the "Open" button.
    7) In WHEN-BUTTON-PRESSED trigger of OPEN item, TESTFORM2 is opened using the following statement :
    open_form(‘TESTFORM2',no_activate,no_session,SHARE_LIBRARY_DATA);
    Since its NO_ACTIVATE, the code flows without giving handle to TESTFORM2.
    8) After invoking OPEN_FORM, a GO_FORM(‘TESTFORM2’) is now called to set the focus to TESTFORM2
    PROBLEM AT HAND
    ===============
    After Step 8, I notice that it passes the focus to TESTFORM2, and statements after go_form (in Parent Form trigger) doesnot executes.
    I need go_form with no_activate, similar to open_form.
    Edited by: harishgupt on Oct 12, 2008 11:32 PM

    isn't it easier to find a solution without a second form? If you have a second window, then you can navigate and code whatever you want.
    If you must use a second form, then you can handle this with WHEN-WINDOW-ACTIVATED and meta-data, which you have to store in global variables... ( I can give you hints if the one-form-solution is no option for you )

  • Open the form from another form...

    How can I open the form from another form with the PL/SQL code???
    The my form are create from OracleDesigner and developed with OracleBuilder.
    Regards
    Basilisco Giorgio

    You can read "About calling reports, displays, and other forms from generated forms" topic in the Designer on-line help. By the way in Forms there are CALL_FORM,OPEN_FORM and NEW_FORM built-ins.
    Helena

  • How can I embed an DOCTYPE HTML Form from Adobe Forms central into a responsive html5 page?

    How can I embed an DOCTYPE HTML Form from Adobe Forms central into a responsive html5 page?
    -Luis

    Hi,
    You can embed the form on your website, but you need to make sure that javascript has been enabled in the browser. You need to copy the embed code and add it into your HTML code. If you would like FormsCentral to generate embeded HTML form without using javascript, you may post a feature request and vote it. Hope it helps! Thanks!
    Kind regards,
    Shiyao Bao

  • How to refer the trigger written in one form from another form ?

    How to refer the trigger written in one form from another form ?
    Thanks,
    Ravi Shankar

    Try to convert the PL/SQL code from Forms trigger into a PL/SQL library(.PLL),
    and then attach that PLL in your forms.
    Note that all Forms objects should be referenced indirectly, for example,
    you have to rewrite
    :B1.DEPT_CODE := :B2.DEPT_CODE;
    :B3.TOTAL_AMOUNT := 100;
    ==>
    copy('B2.DEPT_NO','B1.DEPT_NO');
    copy('100','B3.TOTAL_AMOUNT');
    This is the best way to share PL/SQL code among Oracle Forms.

  • HOW TO CALL A FORM FROM ANOTHER FORM

    HOW TO CALL A FORM FROM ANOTHER FORM [local machine]

    Balraj wrote:
    HOW TO CALL A FORM FROM ANOTHER FORM [local machine]The way you asked question is this bit of request or order?
    Secondly, you used capital latters which are being treated as Shouting Language. So, always try to switch off the Capslock of your keyboard.
    Thirdly, you are very lazy to serach on forum or google for your problem instead of waiting someone to anwer your question.
    Your should seriously have a look at FAQ.
    http://wikis.sun.com/display/Forums/Forums+FAQ
    Also here.
    http://www.catb.org/~esr/faqs/smart-questions.html
    Please read documentation for the initial questions.
    -Ammad

  • Passing Parameter to report (html) from html page

    Hi
    I have a html page use web application server as tool, this page
    link to report, I want to pass the parameter to report
    paramform.
    This is my PL/SQL
    procedure eqp_form(ceqp in out mms_eqp_master.eqp_code%type) is
    htp.tableData(htf.anchor(report.print('msr_eqp_group'),'<font
    color=ffffff>Eqp Group
    Report</font>',cAttributes=>'target=target_blank'));
    How can I do to pass 'ceqp' into report parameter form, before
    running report?

    <p>In the scenario you described the report that connects to the stored procedure will automatically require parameters so they can be passed to the stored procedure.</p><p>Here is a link to a sample that passes a parameter to a report at runtime using BusinessObjects Enterprise XI R2:</p><p>http://diamond.businessobjects.com/node/1018 </p><p>Rob Horne<br /><a href="/blog/10">Rob&#39;s blog - http://diamond.businessobjects.com/blog/10</a></p>

  • Pass parameter to reports server

    1 – I’ve created a report with the following query
    select * from scott.emp where depno = :pdep
    2 – then I configured an oracle portal to access this report
    3 – then in the portal in the tab optional parameters I put the parameter pdep
    4 – Executing through the option Customize in the portal, putting a value to the parameter pdep, the report runs perfectly
    5 – Runnig the report through a pl/sql like:
    htp.tableData(htf.anchor('MANAGER.RPT_BOLETO.show?pdep=' || i..deptno,htf.img( './docs/FOLDER/GESTETNER/IMGS/B.GIF', calt => 'GERAR BOLETO BANCARIO', cattributes => ' border=0"')),'center');
    I get the message PARAMETER MISMATCHE
    6 – I observed that if I change the parameter p_pdep the error doesn’t happen, but the parameter don’t go the report server and the report comes blank
    How can I pass this parameter to reports server?

    Hi Mandeep,
    Could you please tell me how can i pass data parameter from forms to report through run_product.

  • Passing parameter in report for order by clause

    how can we pass the name of the column on which we want the order by clause to sort as a parameter through parameter from in a report??

    Hi Guptha,
    We can create a bind parameter in report and we can send it as a parameter or enter in the parameter form.
    The Query will be
    select * from emp
    order by :Order_Bu_Column
    I think it will help you.
    Regards,
    Siva.

Maybe you are looking for

  • How to dispplay line items in script ?

    dear experts, i want to display the line items in box, but that box should be dynamic according the number of line items thanks in advance.

  • One Itunes library for Ipod and touch

    I have a 5th generation Ipod and plan on upgrading to the Ipod touch. Can I keep my one itunes library for both devices or does each device have to have its own itunes account/library?

  • Item serial numbers are not sequence in GOA

    Hello SDNers i create a GOA for three items 01 10000001 02 20000001 03 30000003 now i am holding the contract and again i am negotiating the price with vendor and decided drop an idea for  20000001 so i delete a GOA for second item 02. Existing  Stan

  • Delivery Block against Advance Payment

    Dear Friends, Please let me know the process through which we can block the delivery for the payment terms where there is any advance to be received. Rgds Anis

  • Anyone know how to find and replace a hard drive cable fo an HP Pavilion zv5160us laptop?