Problem while binding variable progmatically shared variable in RT

Hi All,
I have a problem while programaticaly binding the shared variable from RT controller.
The application scenario is as follows 
I have three cFP controllers and two
server PCs in my application. Servers are implemented with Redundancy. If server
1 fails, server 2 will take care and vice versa. The cFP controller program is
intelligent enough to detect this switching and identify the active server.
I am using shared variable
communication for transferring the data between cFP and Active Server. This I am
achieving by binding the cFP variable to Server variables. I can bind server
variables to cFP variables also. But I have some advantage with first one rather
than second one.
Now, cFP Variable to Server Variable
binding I can do in two ways.
Right click the variable in Project
Explorer and select the network URL.
Other method is by programmatic
binding.
Now Programatic binding should be
done in cFP controller since cFP controller should bind to second server
whenever it detects switching.
For this, I tried with
SharedVariableIO property node like in the below attached diagram 1.
But I was getting a deployment error
shown in attached diagram 2.
The second method I tried is by
transferring a shared variable library cFP Library.lvlib to cFP through FTP and
opening the Library variable reference and by using the variable property node.
This way of binding was successful when I run from windows PC. But in RT
controller, it was giving me Error 1 while opening a
library.
I am attaching the code with this post
Summary of the problem is I am not able to progmatically bind variables from
RT Controllers
Kindly help me in solving this
problem.
Regards,
Blackperl
Message Edited by blackperl on 08-18-2008 08:29 AM
Message Edited by blackperl on 08-18-2008 08:31 AM
Attachments:
Code and Library.zip ‏27 KB
Diagram 1.jpg ‏15 KB
Diagram 2.jpg ‏25 KB

Hi All,
I have a problem while programaticaly binding the shared variable from RT controller.
The application scenario is as follows 
I have three cFP controllers and two
server PCs in my application. Servers are implemented with Redundancy. If server
1 fails, server 2 will take care and vice versa. The cFP controller program is
intelligent enough to detect this switching and identify the active server.
I am using shared variable
communication for transferring the data between cFP and Active Server. This I am
achieving by binding the cFP variable to Server variables. I can bind server
variables to cFP variables also. But I have some advantage with first one rather
than second one.
Now, cFP Variable to Server Variable
binding I can do in two ways.
Right click the variable in Project
Explorer and select the network URL.
Other method is by programmatic
binding.
Now Programatic binding should be
done in cFP controller since cFP controller should bind to second server
whenever it detects switching.
For this, I tried with
SharedVariableIO property node like in the below attached diagram 1.
But I was getting a deployment error
shown in attached diagram 2.
The second method I tried is by
transferring a shared variable library cFP Library.lvlib to cFP through FTP and
opening the Library variable reference and by using the variable property node.
This way of binding was successful when I run from windows PC. But in RT
controller, it was giving me Error 1 while opening a
library.
I am attaching the code with this post
Summary of the problem is I am not able to progmatically bind variables from
RT Controllers
Kindly help me in solving this
problem.
Regards,
Blackperl
Message Edited by blackperl on 08-18-2008 08:29 AM
Message Edited by blackperl on 08-18-2008 08:31 AM
Attachments:
Code and Library.zip ‏27 KB
Diagram 1.jpg ‏15 KB
Diagram 2.jpg ‏25 KB

Similar Messages

  • Problem while Binding multiple Parameters to View Object[Solved]

    Hello,
    I am facing problem while binding multiple parameters with different data types in View Object query. For example suppose I have following query in my view object.
    SELECT Header.ADDED_BY
    Header.BATCH_ID,
    FROM BATCH_HEADER Header
    WHERE :1='deptAdmin' and Header.BATCH_ID
    in
    select batch_id from batch_header_dept_mapping where dept_id in(SELECT * FROM TABLE(CAST(:0 AS TABLE_OF_VARCHAR)))
    I am able to pass the Bind variables of Array type for : 0 , using Steve's ArrayOfStringDomain example. (ArrayOfStringDomain) .
    But after passing value to second bind parameter ie.. :1 .
    I am getting the error as follows.
    ## Detail 0 ##
    java.sql.SQLSyntaxErrorException: ORA-00932: inconsistent datatypes: expected - got CHAR.
    I tried to set
    setWhereClauseParam(1,11); // 11 is Number
    setWhereClauseParam(0,arr); // arr is arr = new Array(descriptor,conn,deptid); for in parameter.
    But of no use , Please let me know if any thing missing form me or have any another solutions. Also please provide me any example if have.
    Thank you,
    Sandeep
    Edited by: user11187811 on Oct 23, 2009 7:27 AM
    Edited by: user11187811 on Oct 26, 2009 12:52 AM
    Edited by: user11187811 on Oct 26, 2009 6:51 AM

    hi.
    but when using non-Oracle named parameter binding styles as you've done (ie. , :1), regardless of what number you give each bind variable, they are sequenced 0, 1, 2 etc. As such your bind variable :1 is the 0th parameter, and your bind variable  is the 1st parameter.Your statment is correct.
    :1 i used was actually on 0th position and :0 was on 1 position. Like you said in sequence 0,1,2 etc. Now i get the answer and i corrected My mistake by assigning right values to right binding variable. and problem just solve.
    Thanks Chris.

  • Blink while alarm on using shared variables with remote panel

    I am creating an application where I have front panel indicators data bound to shared variables.  I also set it up to have them blink when the alarm is on.  I am using the DSC module.
    This works great under the development environment.  But when I connect using the remote panel, I can no longer see the blinking indicator if there is an alarm.  I can see the blinking indicator on the machine that is running the program, but no on any of the remote panels (I have no problems connecting to the remote panel and controlling the program).
    I have the remote panel set as embedded, since I want the user to be able to change some settings over the network.
    I am sure I am missing something simple, any ideas??
    thanks
    Kenny

    I have been using IE6 and Firefox, and I have found that the blinking does show up, if you refresh the page.  And then if the alarm stops and the blinking stops, you will not notice it until you refresh again.
    Kenny

  • Problems with builded app and shared variables

    I got connection error message (Invalid server: cannot connect to server) when selecting a shared variable using dashboard. The app is running on a Win7 PC.
    I have no problem connecting the PC's IP at my dashboard indicator, even, I can select the shared vars library of my app.
    I opened the ports on Windows and Router TCP: 2343, 59000-60000 UDP: 2343, 6000-6010, and created new inbound rules for the kads.exe, lktsrv.exe and tagsrv.exe programs and installed the Run-Time 2013 engine on that PC. By the way, the application also has HTML files created with the web publishing tools that is working OK.
    When I test the application on my develop PC (with LabVIEW 2013) everything works fine.
    Did I miss something?

    Hello jesushidalgo,
    Make sure that there is not a personal firewall enabled on either computer that could be blocking the NI-PSP packets.
    Acess http://digital.ni.com/public.nsf/allkb/6E37AC5435E44F9F862570D2005FEF25?OpenDocument and see the solution.
    Acess: http://www.ni.com/white-paper/12402/en/  to see how configure software and hardware Firewalls to support National Instruments Products.
    Tell me if worked, ok?
    Best Regards
    Rita Souza
    Engenharia de Aplicações
    National Instruments Brazil

  • Problems writing to network published shared variable hosted on rt (set as modbus slave for crio)

    Hello Ni Forums
    This is my first post on this forum and I have been using labview for about 8 months now
    I have a problem regarding writing data to modbus registers through an i/o server set as a modbus slave for my 9074 hardware.After I have completed building project and deploying the variables and following instructions from here , it yields no result but a line zeros. I have the Ni DSM open and modbus master setup to see whether the data is actually being read/written from the respective sides which both yield the same line of zeros as well.  What I am actually trying to write to is an array of single precision floating data. The registers are structured from ranges F40000-F46534 for 10 elements or have them for range AF40001L1-AF46534L1 of item AF40001L10 where it is an array of length 10. (Referenced ranges here)
    I know 1 thing for sure, the modbus connection works and is ready for data requests, I tested this through NI DSM and manually set data for and my master received them . 
    System and Project specifications
    Windows 7 OS
    Labview Full Development System 2011
    No Labview DSC module but I am using the real time module as referenced by one of the documents
    This project is a real time application with fpga mode (not scan interface mode)
    The master and slave are the same subnet and network
    Modbus Connection Type: TCP
    9074 compact rio 8 slots
    9234 module x3 
    9221 module x1
    9472 module x1
    Shared Variable Engine service running on windows os and rtos system 
    Used this  guide to learn about the modbus protocol as I searched all over the internet to learn about modbus 
    I already having Modbus IO Server software installed on the crio through ni max version 1.8 for NI RIO 4.0
    attached file(s)
    Image of Crio software specifications
    Image of the Data being written into variable in rt block diagram
    Short Version of the problem: Why is the io variable not being written into with properly converted data?

    The data can have zeros but not all of them will be zeros and I have another program (on local computer for database storage)that is recieving the same data through TCP and they are not zeros. 
    If a machine is running and is active then the data that will be collected should not be zero , it should infact  be some analog value > 0.
    I will look into the function you described
    How do you view the errors in the IO server subfolders ?
    Is it the modbus register called error status that returns an error code if so that value is currently 0 
    Regards mzamstl
     

  • Front Panel binding of shared variables very slow initialization / start

    Hello @ all,
    I am using a server running Windows2000 and LV 8 DSC RTS for datalogging. All shared variables are deployed on that server.
    I am now facing the problem, that all front panels running on the clients using the network shared variables on the server take very long to sync on startup. First the flags on the controls bind to the shared variables turn red, after up to ten minutes they start to turn green. The panels use up to 40 controls bind to the shared variables.
    All firewalls are turned off. I tried to connect the client to the same switch the server is connected to. Same problem. Does anybody have a clue?
    Thx for your quick answers.
    Carsten 

    While I can't offer any solution to your problem, I am having a similar issue running LV8.0 and shared variables on my block diagram (no DSC installed).
    When using network published shared variables, it takes anywhere from 30 sec to 4 min from the vi start for any updates to be seen. Given enough time, they will all update normally, however this 4 minute time lag is somewhat troublesome.
    I have confirmed the issue to be present when running the shared variable engine on windows and RT platforms, with exactly the same results.
    In my case, the worst offenders are a couple of double precision arrays (4 elements each). They will normally exhibit similar "spurty" behavior on startup, and eventually work their way up to continuous and normal update rates. Interestingly enough there are no errors generated by the shared variables on the block diagram.

  • Do I have to Bind Shared Variables in Executables?

    I want to have shared variables work between two executables that will be installed on seperate machines.  I've managed to get the code working, but am not satisfied with the approach.
    Attached is a .zip file with my project files that contain what I've been able to get to work.
    What I don't like, is how I need to have double the amount of network variables.  Right now I have a program that is a publisher and another is a subscriber (based on an example provided on this forum at some point).  The Publisher has its own shared variables inside a library, and the subscriber has its own shared variables inside a different library.  The Subscriber's shared variables are "bound" to the Publisher's shared variables in the project file and is a concrete physical network path that cannot be changed.
    Once the executable is made and installed, this works.  I've tried getting it to work w/o one of the executables using a shared variable library that contain bound shared variables through a concrete physical network path but I obviously do not know what I am doing.  Ultimatly, I would like to have a single shared variable library that both the publisher and subscriber use.  I want the publisher executable to post the variables to the variable manager running on the publishers machine, and then have the subscriber program running on the subscriber's machine to consume the shared variables from the variable manager on the publisher's machine.
    Please help me!
    -Nic

    Hey Nic,
    I am going to try and answer those questions for you.
    If you use the DataSocket API to connect to a variable that resides on another machine, is your local machine's variable engine involved at all?
    No, it should not be involved at all.
    If the Variable Engine is not used locally, does it need to be included with your application installer?
    Yes, it is going to need to included with the installer.
    If I'm correct, whats better?  To use the variable engine locally, or to connect directly to a remote variable engine?
    Can you please give a little more information here?  I'm not quite sure if I understand your question.
    The default time-out on the DataSocket Read vi is 10 seconds.  If you are doing multiple DataSocket reads in the same polling loop, one variable may update but the other datasocket read is waiting for its timeout before allowing the loop to itterate.  This creates a really laggy scenario (see progmatic subscriber.vi in the attached .zip).  Setting the timeout to something low, say 10msecs, reduce the "lag" but...
    Having the ability to set a decent time-out is a really nice performance feature that isn't availabe to you when you Bind to a shared variable (I don't think).  It may make performance since to not do any loop iterations until the data from the host has changed.... how to manage this w/o seperating each read into its own loop however is my question.... ???
    Can you please explain this a little more as well?  If I understand you correctly, it sounds like you have many datasockets open in one while loop.  Are you using one datasocket per variable?
    Is there any unseen advantages with using the National Instrument's Shared Variable API over the DataSockets API?
    Shared variables are in general more easier to use, and provide a simple way to implement the idea of passing data between machines.  Obviously, using TCP, you can create more control using your own protocol to exchange information, but in general, Shared Variables are normally just easier to use.
    Feel free to post any questions or dicussion issues here.
    Regards,
    Kevin H
    National Instruments
    WSN/Wireless DAQ Product Support Engineer

  • Using Shared Variables and Initialize Front Panel Binding (to PSP)

    Hi,
    I use LV DSC RT 8.2.1
    I have a Vacuum System That includes signals from - Pumps failure, Valves status, Vacuum gauge, start Pump ...
    Each signal is read by a FieldPoint. 
    All the relevant FieldPoint Channels are read by the Server (a computer in the Ethernet Network) and published to the network in the form of Shared Variables.
    I have a client VI that is reading the Shared Variables published by the Server using Front Panel Binding.
    Problem : 
    Some of the Bindings are in the mode 'Write &Read' and that causes some initialization problems.
    For example - Valve #1 is Open, and then a User start running the Client VI, (the Valve #1 Status mode is 'Write & Read")
                           if in the VI the status of Valve #1 is closed (before running it) then the Valve status is changing to Closed.
    I want the Client VI to first read the Physical status of the instrument and then to change the Value if the User changes it.
    But that's seems to be a problem when using Front Panel Binding... (is it?)
    I know I can Deploy a lvlib in the Client Side and Item Bind to the Shared Variables or Use DataSocket.
    (Is DataSocket is a Reliable method when connecting to Shared Variables? What are the disadvantages when using DataSocket?) 
    What is recommended by those of you that are experienced or by NI ?
    Sincerely Yours,
    Amitai Abramson.

    Amitai Abramson,
    Hello and thanks for using the NI Forums.
    I'm glad that you've read the Using the LabVIEW Shared Variable Tutorial on our website. Check out these other resources:
    Network Variable Technical Overview
    Troubleshooting Network-Published Shared Variables
    Why Do I See Unexpected Value Change Events for Shared Variables Using LabVIEW DSC?
    All You Need to Know About Shared Variables
    Creating a Value Change Event for Shared Variables
    Alternative Method for Using Shared Variables Between Systems in LabVIEW 8.x
    What Is The Difference Between Using Shared Variables And DataSocket VIs To Access OPC Tags?
    The issue that you are seeing by having "Write & Read" bound items on both the server and client side is essentially a race condition, you don't know which one is being read/written at what time. To resolve this issue I would take a look at some of the documents below.
    Using a Local, Global, or Shared Variable in Parallel Loops Can Cause Race Conditions
    Using Local and Global Variables Carefully
    Tutorial: Local Variable, Global Variable, and Race Conditions
    Locking a Shared Resource or Variable in LabVIEW Using Semaphores
    You mentioned not wanting to have two sets of shared variables (one on each side), but this is a great method to resovle this issue, that, or you can develope some sort of hand shaking to prevent these race conditions.
    I would suggest that in the future when using these forums you try to ask only one question per thread and make it more concise. It's hard to tackle multiple questions and such broad questions as "I want to know all the ways that I can connect to Shared Variables, and I want to know the advantages and disadvantages." I suggest this because we want you to get your questions answered and more concise questions will result in quicker and better answers. 
    Message Edited by Ben S on 10-01-2009 06:05 PM
    Ben Sisney
    FlexRIO V&V Engineer
    National Instruments

  • Network shared variables lose binding

    Hello,
    I am developing an application in LabVIEW that uses network shared variables to transmit data between two PC's on the same subnet. The shared variables work fine when running the VI's in development mode, however, when i build the vi's into an executable I find that they no longer work. Here is what I have found so far:
    I deploy the shared variable library on the publisher machine (also happens to be the development machine) through an invoke node in the executable. NI distributed system manager confirms that this does deploy and indeed updates as it should.
    For the executable on the subscriber PC I created a second shared variable library (same project) with the same shared variables and bound them to the respective shared variables from the first library by selecting enable aliasing, then bind to PSP URL and browsing to the shared variable I wish to bind it to (e.g. \\hallnet-ellm2\shared variable library\serial Number). The machines listed under browse were listed by name so when I tried this initially and it did not work I manually changed the name of my machine in the URL box to the IP address of the publisher hoping that would fix it in case the subscriber could not resolve the publishers machine alias. So now my bind URL read \\192.168.0.1\shared variable library\serial Number.
    As part of the executable on the subscriber I deploy this second shared variable library. NI distributed system manager confirms that this deploys but under quality for an individual variable it has a list of issues (see attached) and the bound variable is not updating. At this point the publisher shared variables are still functioning fine. By clicking on 'edit variable' I can see that the variable on the subscriber is still bound but the PSP URL is now \\localhost\shared variable library\serial number. Changing the PSP URL on the subscriber to \\192.168.0.1\shared variable library\serial number enables the variable to update as expected.However by this time my executable has already picked up the error and does not function.
    I think that the issue lies with the bind URL used on the subscriber as for some reason it does not keep the binding configured in the project and instead changes to 'localhost'. Why is this? Should it not stay bound to the address specified in the project?
    I have tried changing the IP addresses in the aliases file so that
    [My Computer]
    My Computer=localhost 
    becomes
    [My Computer]
    My Computer=ip of local machine
    This did not help.
    The shared variable libraries are included in the build spec to go into the support files directory and they are successfully deployed from there on both publisher and subscriber.
    I am using LabVIEW 8.6 on Windows XP
    Thanks for any help you may be able to offer,
    Lee
    Attachments:
    distributed system manager.JPG ‏74 KB

    Hi Lee,
    I hope you are well.  Thank you for your post.  Your application sounds very interesting.
    Looking at your issue I was wondering, have you tried lowering your firewalls, as this may be causing the problem.
    Also, another option would be to setup a private network.  Do you have access to any routers that you could use to link the two machines independent of your IT's infrastructure?
    The other thing to try is two other computers entirely.  Again, it would be ideal to take them off the network you are on, but it's something to try if my prior suggestion doesn't work.  It should work on the original two machines though, and it's likely that different computers won't solve your problems because I suspect the network.
    Remember that the client variables must know the location of the variables on the server, so you can't move the server exe around without changing this value.
    Make sure to set the network location in the "Bind to Source" option for the client variables.
    It is also possible to write a separate piece of code to install on every machine that is responsible for deploying the library and by doing so eliminate the need for programmatically deploying the variables in the original application.  However, this won't really help you, because the variables you use in the application have to be the same as the ones deployed in the library, so if you change the library, they'll no longer be linked and they won't receive data.  You'd have to create a separate exe for every binding source you wanted to link to, and then have a second, known library for the sake of communication locally on the computer between the ‘deployer’ and the actual application.  The main application could then be assigned the responsibility of launching the correct ‘deployer’' if it sees it needs to switch to a different variable binding source.  This method is not the most streamlined or effective, but it might work.
    Just to let you know, you will need to use the DSC toolkit.
    Please find below some knowledge base links that I think you will find helpful in your application.
    Using Shared Variables in Executables
    How do I Programmatically Change the Data Binding Source for Shared Variables?
    I hope this information helps and if you can give these suggestions a go and let me know how you get on, that would be great.
    Kind regards,
    Prashant M
    Applications Engineer
    NI UK & Ireland

  • Programmatically bind shared variable

    Hi,
    I'm trying to bind a control to a shared variable, if I clic on properties=>Data Binding, everything is set up correctly, but I get a red flag. Then if I add a white space after the variable path then clic OK. everything is fine and working properly.
    My problem is I have to bind hundreds of shared variables so I don't want to modify every single control properties...
    Anyone has any clue on what's happening?
    Rodéric L
    Certified LabVIEW Architect
    Attachments:
    properties.JPG ‏34 KB
    method.JPG ‏18 KB

    Looking at some similar code that I had developed to set FP bindings, I included single quotes in the url, for example:
    \\My Computer\IO\'PU.Heater_Power'
    Maybe the space is satisfying the need for a delimiter of some sort?

  • Binding a variable to a shared variable is taking the attributes of that variable?

    Is it possible that binding to a shared variable to have the attributes of that variable? With other words shared variable shares attributes also?
    Thank you,
    Virginia

    I builed a vi server that prepears data to be updated to an interface and data has all type of attributs such as color, background and foreground, and for this reason I wanted to be able to be updated with attributs.
    I will give up to have like an updated control in my interface but to updated it from the server with detailed attributs in a continous loop instead.
    Data with attributs give me not only the value but the status also.
    Thank you!

  • LV7.1 DSC tag engine VS LV8.6 DSC shared variables

    I'm currently running LV7.1 with DSC and RT. To handle communications and logging RT variables I'm using the init / read / write publish.vi's on the RT side and datasockets on the HMI side (Windows XP). This has worked out great - new tags can be programmatically created in real time with the publsih vi's and then I go to the the .scf file and use the tag configuration wizard to add them to my scf file and handle data logging. This worked very well - the wizard would organize all of the memory tags into folders by block name used by the init publish vi. I could also select entire groups of tags and add hundreds at a time to the .scf file. Hardware Tag also worked in a similar fashion, organizing tags by controller and module folders. Now - looking at LV8.6.I found I can still use the init / read / publish vi's on the RT side - great. However there is not tag configuration editor as in LV7.1 to let me add large numbers of tags through a wizard. The closest thing I've found is to create a library to represent each block name from the RT init publish.vi then use "create bound variables" option under the library to bind the new shared variables to the RT memory tags. I can browse to the tags on the controller by network items, but when I add them it doesn't bring the block name of the tag as it did in 7.1, only the item name. I use a lot of PID loops that share the same tag names (i.e.: P,I,D, mode, output), so not including the block name represents an organizational problem. The problem with this is, it's very labor intensive compared to the wizard in LV7.1 DSC, especially talking about creating systems with thousands of RT memory tags. Also, there is a similar problem with hardware channels (I'm using compact FieldPoint). To log channels via DSC do I have to create a shared variable for each channel to access the DSC logging capabilities? Again how do I add all of the hardware channels in some organized fashion? I hope I'm missing some tool that is an analog to the tag configuration wizard to bring in these channels and organize them. Any help or suggestions would be appreciated. Thanks,Brad

    Hi lb,
    We're glad to hear you're upgrading, but because there was a fundamental change in architecture since version 7.1, there will likely be some portions that require a rewrite. 
    The RTE needs to match the version of DSC your using.  Also, the tag architecture used in 7.1 is not compatible with the shared variable approach used in 2012.  Please see the KnowledgeBase article Do I Need to Upgrade My DSC Runtime Version After Upgrading the LabVIEW DSC Module?
    You will also need to convert from tags to shared variables.  The change from tags to shared variables took place in the transition to LabVIEW 8.  The KnowledgeBase Migrating from LabVIEW DSC 7.1 to 8.0 gives the process for changing from tags to shared variables. 
    Hope this gets you headed in the right direction.  Let us know if you have more questions.
    Thanks,
    Dave C.
    Applications Engineer
    National Instruments

  • How to read shared variables inside event structure ?

    Hi,
    I have a problem that my shared variables do not update inside event structure. The program(s) I am trying to get working is seen in the attached screenshot. It works as follows:
    0. I start the vi that is unsquared.
    1. I write a string to a shared variable using vi in red square. I make sure that its updated using write-wait-read.
    2. I run the other vi (blue square), this changes the boolean shared variable.
    The unsquared vi has been running the whole time, it has event structure bind to boolean shared variable change (the one in blue vi). After I have runned the blue vi, the unsquared vi should change the indicator values to match the ones in red vi. However I have to start the blue vi multiple times to get it to change, sometimes even 6 times.
    Also, when I change the value in red vi to a third value and start blue vi multiple times, the unsquared vi shows all the variables. I.e. I put "cat" to red then start red, put "mouse" to red then start red,... and then start clicking blue... Unsqured shows cat, mouse,..., dog (dog is the default).
    How can I force the shared variable to update inside event sructure. I want the current value of the variable, not some historical values.
    Attachments:
    Screenshot-5.png ‏108 KB

    Found the buffering... disabling it solved the problem... thanks.
    FYI, there is another solution that I just found out... attached. Adding timeout to the event structure and the variable read outside the event structure... This makes the shared variable strings (one that is read outside and the otherone that is read inside) different.
    Could someone explain why the variables are in different state even if they are used in the same place and looped with 10ms intervals?
    Juha
    Attachments:
    Screenshot-6.png ‏110 KB

  • CFP-1808 shared variables timestamp

    Hi,
    I need to control and acquire data from a cFP Ethernet module (cFP-1808) to a PXI RT system. I have tested two ways of doing it:
    1. Bind shared variables to the Fieldpoint channels. Works great except for the fact that I have to record the timestamp of every single channel in all Fieldpoint modules. I have to avoid this. The reason I have to record all timestamps is that sometimes two consecutive reads are the same in value and in timestamp; so even if I make sure I get a value every 100ms in my real time application I cannot trust  that  the shared variable engine will give a real new value every 100ms, because sometimes one read is the same as the previous one. My
    understanding of the technology is that the cFP network interface checks for an
    updated value of the channels of each module at the Advise Rate. If there’s a
    new value the cFP transmits it to the Shared Variable Engine running in the PXI
    controller, but if the value has not changed it doesn’t transmit anything, so
    more efficiency is achieved in the network communication. This would explain the
    timestamp behavior of the shared variables bound directly to Fieldpoint
    channels; since there is no new value the shared variable is not updated so the
    timestamp of two consecutive reads is the same.
    2.  Create a Modbus server and then create shared variables bound to the Modbus server channels. With this method any time my RT application asks for a new value the shared variable engine provides a real new value with an updated timestamp, and all timestamps in the same module are equivalent (in 1usec range).  Therefore, it looks like using the Modbus solution I  only have to record one timestamp per module.
    So option 2 probably fixes my problem, but I'd like to understand why. Both methods use the shared variable engine, shouldn't they behave the same way? There's one downside in option 2, which is having to deal with Modbus addresses and not having the ease of use of option 1 that just browses to find the Fieldpoint channel.
    Any comments?
    A final note, it'd be great to be able to use the Fieldpoint VIs in LV Real-Time! Can this be achieved?
    Raimon

    Hi Raimon,
    How are you binding to your shared variables?  This KB reviews three methods:
    http://digital.ni.com/public.nsf/allkb/FA610367EC62574186257118005089F2?OpenDocument
    I don't believe using FieldPoint VIs on a PXI RT target is possible because FieldPoint is not a driver that you are able to install on the PXI RT target.  We do have the cFP-2xxx line of RT controllers for FieldPoint, which can communicate directly to the FieldPoint modules, ensuring determinism.
    Trey B
    Applications Engineering
    National Instruments

  • How do you synchroniz​e accesses to a LabVIEW Shared Variable?

    I would like to create an ad-hoc weather station program (I'll explain more in a bit).  I am using LabVIEW 8.0 Full Edition, and I would like to share data over a network between stations with the LabVIEW Shared Variable.  Here's what I want to be able to do:
    A node would start up, and begin publishing data to a network via a shared variable.
    The shared variable is an array of clusters
    The cluster information would hold things like:
    Station Name
    Station Location
    Weather information cluster (temperature, rainfall, windspeed, wind direction, etc...)
    Timestamp of last update
    When a new node would like to enter, it would bind to the shared variable, grow the array, and add its information.
    If a node's Station Name and Station Location is already in the shared variable, it would merely update the information in the cluster.
    Viewing nodes could pop in, bind to the shared variable, and read/display the information at any time. 
    I am trying to enumerate problems with this before implementing, and I have run into a stinker of a problem that I am not sure how to solve.  How do I synchronize accesses to the LabVIEW Shared Variable?  If I read the variable, modify it, and write it back, I will undoubtedly run into a race condition where 2 nodes attempt to update its data and I will lose the data written by the first node - Node A reads, Node A modifies, Node B reads, Node A writes, Node B Modifies, Node B Writes, and thus the modifications made by Node A are lost.  In my specific application losing some data isn't critical, but if not remedied this type of problem could cause massive amounts of data to be lost when there are numerous nodes, and that is definitely not acceptable. 
    Does anyone have any recommendations on how to synchronize the read-modify-write operations on the data in the Shared Variable?
    -Danny

    Wendy,
    I am afraid Semaphores are not network-shared objects (to my knowledge), they are system-level objects that use operating-system synchronization mechanisms.  If I were synchronizing on a single machine, a semaphore might be a valid mechanism; as an aside, most user-mode semaphores are designed to synchronize within a single process - to synchronize between processes you need to store the semaphore in the Kernel, and to synchronize over a network you would need a network node to handle serialization of requests.  My Shared Variable is published over a network, and to my knowledge there are no network-published synchronization mechanisms available - mostly because there is no way to currently perform an atomic test-and-set on the Shared Variable (am I correct?) and there isn't a mechanism for blocking access to a Shared Variable from another network device/machine (or is there?).  I've been looking for some way to implement an atomic test-and-set but I am running into a wall; I know that if I select the "single writer" attribute of the Shared Variable I can get LabVIEW to force a single writer allowing me to have an atomic "set", but I need more than that.
    If only there was a network-shared Semaphore or some way to block other network accesses to the Shared Variable I would be in business - something like what I want doesn't exist, does it?
    Thanks!
    -Danny