Project 2010 SP1 Installation Crashes

I'm trying to create a package that will handle both brand new installations for Project 2010 as well as upgrade installations for those running Project 2007, the latter of which represents a large population in our environment.
I basically followed the same process I used when creating packages for Office 2007, Office 2010, Project 2007 and Visio 2007, all of which work today:
run setup.exe /admin
create a new .msp
make my adjustments (very few)
save into Updates directory
customized PrjPro.WW\config.xml (after first creating a backup!)
run setup.exe
I'm testing the package on a machine that previously had Project 2007, but after running for a short time, setup crashes.  I thought maybe the problem was with the config.xml so I undid the changes one at a time, then moved up to restoring the orignal
config.xml file but it continues to crash.
There's a setup log in %temp% that contains what may be the core issue
PERF: TickCount=2427515 Name=OBootStrapper::Run Description=Begin function
Operating System version: 6.1.7601 Service Pack 1. Platform ID: 2
Running 32-bit setup on a 32-bit operating system.
Command line: "\\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\setup.exe"
No command line arguments given
Verify file signature in "\\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\setup.exe"
\\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\setup.exe is trusted.
Verify file signature in "\\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\PrjPro.WW\OSETUP.DLL"
\\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\PrjPro.WW\OSETUP.DLL is trusted.
Using setup controller dll at [\\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\PrjPro.WW\OSETUP.DLL].
PERF: TickCount=2428342 Name=OBootStrapper::Run Description=Calling RunSetup
PERF: TickCount=2428342 Name=RunSetup Description=Begin function
Catalyst execution began: 03/07/2014 13:30:43.
Setupexe Resiliency Mode is set to [PerformIfApplicable]; thus Resiliency is [disabled] for the [InstallExecutionMode]
Searching for updated versions of resource files under the 'updates' folder [\\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\updates].
Found [0] resource files under the update folder.
Searching for default versions of resource files under the folder [\\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660].
Found [1] resource files under the default folder.
Running in [InstallExecutionMode]. Run from TEMP folder at [C:\Users\myuserid\AppData\Local\Temp\Setup00001fb8].
Loaded resource file [C:\Users\myuserid\AppData\Local\Temp\Setup00001fb8\OSETUPUI.DLL] (CultureTag=en-US).
Loaded Dll : \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\PrjPro.WW\OSETUP.DLL.
Catalyst version is : 14.0.4755.1000
JobExecutionMode is InstallExecutionMode.
Check if Office is supported on Windows 6.1.7601
Checking if CLSID_DOMDocument60 can be created.
Checking the version of MSXML6.
MSXML version check passed. Minimum required version is [6.10.1129], installed Version is [6.30.7601.17988].
LIS: start parsing setup xml
LIS: finished parsing LIS package "{90140000-0115-0409-0000-0000000FF1CE}"
LIS: start parsing setup xml
LIS: finished parsing LIS package "{90140000-0116-0409-1000-0000000FF1CE}"
LIS: start parsing setup xml
LIS: finished parsing LIS package "{90140000-003B-0000-0000-0000000FF1CE}"
LIS: start parsing setup xml
LIS: finished parsing LIS package "{90140000-00B4-0409-0000-0000000FF1CE}"
LIS: start parsing setup xml
LIS: finished parsing LIS package "{90140000-002C-0409-0000-0000000FF1CE}"
LIS: start parsing setup xml
LIS: finished parsing LIS package "{90140000-0010-0409-0000-0000000FF1CE}"
Product: PRJPRO
AddOnGroup Culture: en-us
AddOnId: OFFICE.EN-US
AddOnId: PROJECT.EN-US
AddOnId: PROOFING.EN-US
No upgradable applications found
Parsing config.xml at: \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\PrjPro.WW\config.xml
Preferred product specified in config.xml to be: PRJPRO
Parsed setting: SETUP_REBOOT with value: Never in config.xml.
Logging type verbose specified in config.xml.
Log directory: C:\Users\myuserid\AppData\Local\Temp specified in config.xml
Log file template: Microsoft Office Project Professional Setup(*).txt specified in config.xml
COMPANYNAME specified in config.xml.
USERNAME specified in config.xml.
Product Deployment Mode: PerMachineManaged
Target Deployment Account Security Identifier: S-1-5-18
Loading package metadata: \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\Office.en-us\OfficeMUI.xml
Loading package metadata: \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\Office.en-us\OfficeMUISet.xml
Loading package metadata: \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\Proofing.en-us\Proof.es\Proof.xml
Loading package metadata: \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\Proofing.en-us\Proof.fr\Proof.xml
Loading package metadata: \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\Proofing.en-us\Proof.en\Proof.xml
Loading package metadata: \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\Proofing.en-us\Proofing.xml
Loading package metadata: \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\Project.en-us\ProjectMUI.xml
Loading package metadata: \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\PrjPro.WW\PrjProWW.xml
Reading value of unintialized setting!
BRANDING: Parsing Branding Data...
BRANDING: Parsing Branding Data...
Pidkey specified in config.xml or setup.xml file. Skipping PidKey view.
Kicking off chained install...
PERF: TickCount=2434333 Name=Job::DoCacheWork Description=Begin function
OSE is detected as a registered service. Service binary is reported at location: C:\Program Files\Common Files\Microsoft Shared\Source Engine\OSE.EXE
OSE service binary is detected at location: C:\Program Files\Common Files\Microsoft Shared\Source Engine\OSE.EXE
OSE is avaliable at C:\Program Files\Common Files\Microsoft Shared\Source Engine\OSE.EXE
This OSE has version: 12.0.4518.1014. Skip using this version of OSE because its version is too low.
Running Source Engine process detected
Running version: 12.0.4518.1014
Error checking already running ose version. Error code 0x00000000
Stopping running the problematic Source Engine process
Error attaching to OSE, error 0x00000000
Cannot start standalone OSE. from \\path\to\Microsoft Project 2010\SW_DVD5_Project_Pro_2010w_SP1_W32_English_MLF_X17-76660\PrjPro.WW\ose.exe. Error code: 0x80070102
Error: Unable to select Source Engine process to start, see debug level logs for detail Type: 88::UnexpectedError.
Error: Unable to select Source Engine process to start, see debug level logs for detail Type: 88::UnexpectedError.
Error: Unable to select Source Engine process to start, see debug level logs for detail Type: 88::UnexpectedError.
Error: Unable to select Source Engine process to start, see debug level logs for detail Type: 88::UnexpectedError.
Catalyst execution finished: 03/07/2014 13:32:07. Return code: 30088. Exception caught: UnexpectedError.
PERF: TickCount=2511881 Name=RunSetup Description=End function
I've checked a few things but I can't figure this out
restored config.xml
used no msp
Office Source Engine (OSE) service startup type is set to 'Manual'
copied ose.exe again from DVD
copied entire DVD over again
I'm beginning to wonder if there's an issue with the existing Project 2007 installation, or the way it was uninstalled [by the Project 2010 setup] - but maybe its something altogether different.
Any advice is greatly appreciated.

My point above is that Project 2007 was extremely buggy and unless files are saved using Project 2007 SP3 first you are likely to experience problems with the files when opening in project 2010. Project 2007 to 2010 with no service packs is problematic.
With SPs applied you should have far fewer problems.
Doesn't look like a exe with SP2 is available yet so you need to add the service pack separately, probably in the updates folder.
If all Project 2007 installs are already at SP3 then no need for this.
Rod Gill
Author of the one and only Project VBA Book
www.project-systems.co.nz

Similar Messages

  • Access 2010 SP1 - random crashes relating to vbe7.dll

    We are experencing the same problem as described here in a post on
    Microsoft Answers.  However was are also still occasionally seeing the problem after uninstalling SP1. 
    Has anyone come across any better workarounds? 
    Microsoft: can we please have some information on when this is likey to be fixed - this is a major problem!
    After installing Office 2010 SP1, you may receive random crashes when opening objects in certain databases and when trying to open the VBA window in those databases.  If you look in the event viewer the crash info may look similar to the following:
    Faulting application: msaccess.exe
    Version: 14.0.6024.1000
    Stamp: 4d83e4fc
    faulting module: vbe7.dll
    version: 7.0.16.19
    stamp: 4d430aec
    Workaround:
    Microsoft is aware of the issue and it is currently being investigated.  In order to work around the problem, you can try the following:
    1.      Make a copy / backup of your database.
    2.      On the problematic machine decompile the database by running the following from a Run command line: MSACCESS.EXE <path to database file> /decompile
    (example: C:\Program Files (x86)\Microsoft Office\Office14\MSAccess.exe "C:\folder\database.accdb"  /decompile)
    3.      Close the database.
    4.      Open the database again normally.
    In addition to this, if you experience the crash please send the error report when prompted to do so after the crash.

    Hello,
    Have you tried the workaround? It should work after you decompile your databases.
    And if there is better solution released by Microsoft, you will be able to find them in certain KB like:
    http://support.microsoft.com/kb/2533794
    Sincerely,
    Max Meng
    Forum Support
    Please remember to
    mark the replies as
    answers if they help and
    unmark them if they provide no help.
    If you have any feedback on our support, please contact
    [email protected]

  • SCCM 2012 - Project 2010 Standard deployment failed with error 1603

    Hi everyone,
    I’m in the progress to roll out a software deployment via SCCM 2012, it’s to remove the current Project 2010 Professional we installed and reinstall the Standard version. We got a task sequence for the job, which is Reboot>Un-install Project 2010 Pro>Reboot>Install
    Project 2010 Std.
    The Un-installation process uses this command: setup.exe /uninstall PrjPro /config "PrjPro.WW\uninstall.xml"
    The Installation process uses this command: setup.exe /adminfile project_silent_install.MSP
    But the deployment result is quite random, some of the PCs would succeed without any issue, some of them with fail at the installation process with 1708/1603 error. As far as I know we use standard Win 7 64bits SOE across the environment, so everyone should
    have same system baseline.
    I reviewed some of the failed Project 2010 Standard installation logs as it shows the following:
    Executing chained package: PrjStdWW
    05/09/2014 20:16:14 Installing chained package: PrjStdWW
    PERF: TickCount=530512 Name=Verify MSI local install source Description=Begin function
    OSE is detected as a registered service. Service binary is reported at location: C:\Program Files (x86)\Common Files\Microsoft Shared\Source Engine\OSE.EXE
    OSE service binary is detected at location: C:\Program Files (x86)\Common Files\Microsoft Shared\Source Engine\OSE.EXE
    File at \\SCCM2012\SMSPKGE$\PC100139\PrjStd.WW\ose.exe has version: 14.0.4730.1010
    File at C:\Program Files (x86)\Common Files\Microsoft Shared\Source Engine\OSE.EXE has version: 14.0.4730.1010
    Running OSE version 14.0.4730.1010
    OSE is detected as a registered service. Service binary is reported at location: C:\Program Files (x86)\Common Files\Microsoft Shared\Source Engine\OSE.EXE
    OSE service binary is detected at location: C:\Program Files (x86)\Common Files\Microsoft Shared\Source Engine\OSE.EXE
    File at \\SCCM2012\SMSPKGE$\PC100139\PrjStd.WW\ose.exe has version: 14.0.4730.1010
    File at C:\Program Files (x86)\Common Files\Microsoft Shared\Source Engine\OSE.EXE has version: 14.0.4730.1010
    Running OSE version 14.0.4730.1010
    LIS: wait for package "{90140000-003A-0000-0000-0000000FF1CE}" to complete caching
    LIS: package "{90140000-003A-0000-0000-0000000FF1CE}" caching completed
    PERF: TickCount=530528 Name=Completed verify local install source Description=End function
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Use Shell UI transform : LIS\{90140000-0115-0409-0000-0000000FF1CE}\ShellUI.MST
    Current transform is at path: LIS\{90140000-0115-0409-0000-0000000FF1CE}\ShellUI.MST
    OSE is detected as a registered service. Service binary is reported at location: C:\Program Files (x86)\Common Files\Microsoft Shared\Source Engine\OSE.EXE
    OSE service binary is detected at location: C:\Program Files (x86)\Common Files\Microsoft Shared\Source Engine\OSE.EXE
    File at \\SCCM2012\SMSPKGE$\PC100139\PrjStd.WW\ose.exe has version: 14.0.4730.1010
    File at C:\Program Files (x86)\Common Files\Microsoft Shared\Source Engine\OSE.EXE has version: 14.0.4730.1010
    Running OSE version 14.0.4730.1010
    Using transform at path: C:\MSOCache\All Users\{90140000-0115-0409-0000-0000000FF1CE}-C\ShellUI.MST
    Catalyst Package Install...
    Package: PrjStdWW
    File: C:\MSOCache\All Users\{90140000-003A-0000-0000-0000000FF1CE}-C\PrjStdWW.msi
    Command Line: PATCH="\\SCCM2012\SMSPKGE$\PC100139\project_silent_install.MSP" ADDLOCAL=C.35347883.0E64.45B4.88A0.1881DE05E259,OSpp_Core,Project_PIA,SetupExeArpEntry,Office10Fix1,ProductFiles,InternationalSupportFiles_JPN,AceFiles,IMNFiles,OfficeIntlRDC,AceOdbc,OArt_DocTheme,OSetupController,WISPFiles,TCDRegistration,SetLanguageFiles,TCWorks7Files,ClviewFiles,VBAFiles,OfficeAppSupport,TextConverters,ProductNonBootFiles,dummy_Office_PIA,CAGOffice10,VSCommonPIAHidden,WebDiscussFiles,CAGCat10,CAGCat10Clips,MsoInstalledPackagesScoped,WxpFiles,SetupControllerFiles,Forms_PIA,dummy_MSCOMCTL_PIA,AlwaysInstalled,Gimme_OnDemandData,AceRepl,OISFiles,OfficeOLESupport,OfficeMSProof6,CAGFiles,InternationalSupportFiles_ArialUni,OSpp,Ace_PIA,GraphicsFiltersFile,WebDriveFiles,PROJECTFiles,ProductFiles_B2TR,SetupXmlFiles,OfficePostBoot,DocumentImagingUtils,VSTOCLR35,CAGCategoryFiles,ProjectCommon,VSTO,ProofingParent,MsoCommonShellHandler,OfficeDigitalSFiles,CARegistryFeature,OfficeCoreRDC,SetupExeAddRegistry,NonC2R_ProductFiles,MSSOAP3,TranslationCore,CAGOffice10Clips REMOVE=WISPHidden ARPENTRY_NOMODIFY="#0" ARPENTRY_MODIFYPATH="""C:\Program Files (x86)\Common Files\Microsoft Shared\OFFICE14\Office Setup Controller\setup.exe"" /modify PRJSTD /dll OSETUP.DLL" INSTALLLOCATION="C:\Program Files (x86)\Microsoft Office\" SLD_OEMPIDKEY="0" ARPENTRY_NOELEVATEONMODIFY="#0" SETUP_REBOOT="never" COMPANYNAME=" " ARPENTRY_SKUCOMPONENTS="[~]C:\Program Files (x86)\Common Files\Microsoft Shared\OFFICE14\Office Setup Controller\Office.en-us\setup.xml[~]C:\Program Files (x86)\Common Files\Microsoft Shared\OFFICE14\Office Setup Controller\Proofing.en-us\setup.xml[~]C:\Program Files (x86)\Common Files\Microsoft Shared\OFFICE14\Office Setup Controller\Project.en-us\setup.xml[~]C:\Program Files (x86)\Common Files\Microsoft Shared\OFFICE14\Office Setup Controller\Office64.en-us\setup.xml[~]C:\Program Files (x86)\Common Files\Microsoft Shared\OFFICE14\Office Setup Controller\PRJSTD\setup.xml[~]" ARPENTRY_HELPLINK="" ARPENTRY_DISPLAYICON="C:\Program Files (x86)\Common Files\Microsoft Shared\OFFICE14\Office Setup Controller\OSETUP.DLL,1" ARPENTRY_DISPLAYNAME="Microsoft Project Standard 2010" ACCEPTEDEULA="1" ARPENTRY_DISPLAYVERSION="14.0.4763.1000" BRANDING_XML="C:\Windows\TEMP\Setup00001048\BRANDING.XML" SLD_SUPPORTSBYPASS="0" SLD_ACID="5DC7BF61-5EC9-4996-9CCB-DF806A2D0EFE" SLD_TRIALTYPE="0" ARPENTRY_PACKAGEREFS="[~]OfficeMUISet.en-us[~]OfficeMUI.en-us[~]Proofing.en-us[~]Proof.en-us[~]Proof.es-es[~]Office64MUISet.en-us[~]PrjStdWW[~]Office64WW[~]Office64MUI.en-us[~]ProjectMUI.en-us[~]Proof.fr-fr[~]" SLD_DPID="#xF804000004000000380032003500300033002D00300030003000390038002D003000300031002D003000300030003000310030002D00300033002D0031003000330033002D0037003600300031002E0030003000300030002D0031003200390032003000310034000000000000000000000000000000000000000000000000000000000000000000350064006300370062006600360031002D0035006500630039002D0034003900390036002D0039006300630062002D00640066003800300036006100320064003000650066006500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000500072006F006A0065006300740053007400640056004C00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000A09E4657B64703B2F32E339838F004006FE4EEC0394DE6AB2D77DCABCBC8F1C3B8B617EF54ACB52805F38EE560D0B738230977F4AB92430B37CBF02B49DB7636DCF15CE7E175CCF354E009C7A02432315800310036002D0030003800300035003100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000056006F006C0075006D0065003A00470056004C004B00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000006C0074004B004D00530000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000" REMOVESAMEVERSION="" SLD_LICENSETYPE="6" SETUPEXEINSTALLUICULTURE="en-US" ARPENTRY_SHELLUITRANSFORMLANGUAGE="en-US" USERNAME=" " ARPENTRY_CONTACT="" ARPENTRY_HELPTELEPHONE="" ARPENTRY_PRODUCTCODES="[~]{90140000-00B4-0409-0000-0000000FF1CE}[~]{90140000-002C-0409-0000-0000000FF1CE}[~]{90140000-003A-0000-0000-0000000FF1CE}[~]{90140000-002A-0000-1000-0000000FF1CE}[~]{90140000-001F-0C0A-0000-0000000FF1CE}[~]{90140000-001F-0409-0000-0000000FF1CE}[~]{90140000-001F-040C-0000-0000000FF1CE}[~]{90140000-0115-0409-0000-0000000FF1CE}[~]{90140000-006E-0409-0000-0000000FF1CE}[~]{90140000-002A-0409-1000-0000000FF1CE}[~]{90140000-0116-0409-1000-0000000FF1CE}[~]" ARPENTRY_INSTALLLOCATION="C:\Program Files (x86)\Microsoft Office\" SETUPEXE_DOARPWRITE="1" ACIDS="11B39439-6B93-4642-9570-F2EB81BE2238;5DC7BF61-5EC9-4996-9CCB-DF806A2D0EFE;B6E9FAE1-1A0E-4C61-99D0-4AF068915378" ARPENTRY_SPPSKUID="[~]5DC7BF61-5EC9-4996-9CCB-DF806A2D0EFE[~]" ARPENTRY_NOREMOVE="#0" SLD_PKU="0" SLD_PID="82503-001-0000106-49615" LICTYPE="ltKMS" ARPENTRY_UNINSTALLSTRING="""C:\Program Files (x86)\Common Files\Microsoft Shared\OFFICE14\Office Setup Controller\setup.exe"" /uninstall PRJSTD /dll OSETUP.DLL" ARPENTRY_NOREPAIR="#1" ARPENTRY_URLUPDATEINFO="" ARPENTRY_URLINFOABOUT="" REMOVEPREVIOUS="" ARPENTRY_CACHELOCATION="C:\MSOCache\All Users" REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\" ARPSYSTEMCOMPONENT=1 TRANSFORMS="C:\MSOCache\All Users\{90140000-0115-0409-0000-0000000FF1CE}-C\ShellUI.MST" ALLUSERS="1"
    PERF: TickCount=530543 Name=MsiPackage::Install Description=Calling OMsiInstaller::InstallProduct for package file "C:\MSOCache\All Users\{90140000-003A-0000-0000-0000000FF1CE}-C\PrjStdWW.msi"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Error: Failed to install product: C:\MSOCache\All Users\{90140000-003A-0000-0000-0000000FF1CE}-C\PrjStdWW.msi ErrorCode: 1603(0x643).
    Log level changed from: Standard to: Verbose
    Rolling back chain
    05/09/2014 20:18:47 Rolling back package: PrjStdWW
    There appears to be no rollback work to do for package: PrjStdWW path: C:\MSOCache\All Users\{90140000-003A-0000-0000-0000000FF1CE}-C\PrjStdWW.msi
    05/09/2014 20:18:47 Rolling back package: Office64WW
    Package Office64WW was uninstalled in the chain... installing with previous feature states as part of chain rollback...
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Catalyst Package Uninstall Rollback (install)...
    Package: Office64WW
    File: C:\MSOCache\All Users\{90140000-003A-0000-0000-0000000FF1CE}-C\Office64WW.msi
    Command Line: ADDLOCAL=AcePiaReg64,VSTO64,WordXmlEditVerb64,ExcelXmlEditVerb64,GrooveShellIntegration64,Project64Files,OSpp64_Core,ExcelPiaReg64,GraphPiaReg64,FormsPiaReg64,SmartTagPiaReg64,PPTXmlEditVerb64,MsoInstalledPackagesScoped,OfficeExample64bitFilesA,WAC_XmlEditVerb64SPD,SetupXmlFiles,WordPiaReg64,Outlook64Files,AlwaysInstalled64,VBEPiaReg64,VisioPiaReg64,Outlook64SearchShellReg,OneNote64Files,SetupControllerFiles,ProjectPiaReg64,SearchFilters64Files,OutlookPiaReg64,Gimme_OnDemandData,Visio64ShapeSearch,WAC_PIARegSPD64,ProductNonBootFiles64,XDocsPiaReg64,PublisherPiaReg64,OneNotePIAReg64,ProductFiles64,OfficeExample64bitFilesB,OfficePiaReg64,Visio64Files,TCDRegistration64,OSpp64,XDOCSFiles64,XDocsXmlEditVerb64,MsoCommonShellHandler64bit,AccessPiaReg64,PowerPointPiaReg64 REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Successfully rolled back the configuration of package: Office64WW ProductCode:{90140000-002A-0000-1000-0000000FF1CE}
    05/09/2014 20:18:56 Rolling back package: ProjectMUI.en-us
    Package ProjectMUI.en-us was installed in the chain... uninstalling as part of chain rollback...
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Catalyst Package Install Rollback (uninstall)...
    Package: ProjectMUI.en-us
    Product Code: {90140000-00B4-0409-0000-0000000FF1CE}
    Command Line: REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Successfully rolled back install of package: ProjectMUI.en-us path:C:\MSOCache\All Users\{90140000-00B4-0409-0000-0000000FF1CE}-C\ProjectMUI.msi
    05/09/2014 20:19:00 Rolling back package: Proofing.en-us
    Package Proofing.en-us was uninstalled in the chain... installing with previous feature states as part of chain rollback...
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Catalyst Package Uninstall Rollback (install)...
    Package: Proofing.en-us
    File: C:\MSOCache\All Users\{90140000-002C-0409-0000-0000000FF1CE}-C\Proofing.msi
    Command Line: ADDLOCAL=Gimme_OnDemandData,SetupXmlFiles,SetupControllerFiles,MsoInstalledPackagesScopedIntl_1033 REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Successfully rolled back the configuration of package: Proofing.en-us ProductCode:{90140000-002C-0409-0000-0000000FF1CE}
    05/09/2014 20:19:04 Rolling back package: Proof.en-us
    Package Proof.en-us was uninstalled in the chain... installing with previous feature states as part of chain rollback...
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Catalyst Package Uninstall Rollback (install)...
    Package: Proof.en-us
    File: C:\MSOCache\All Users\{90140000-002C-0409-0000-0000000FF1CE}-C\Proof.en\Proof.msi
    Command Line: ADDLOCAL=FindAllWordFormsFiles_1033,Gimme_OnDemandData,SpellingAndGrammarFiles_1033,ThesaurusFiles_1033,MsoInstalledPackagesScopedIntl_1033,HyphenationFiles_1033,OCR_1033,SetupControllerFiles,SetupXmlFiles REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Successfully rolled back the configuration of package: Proof.en-us ProductCode:{90140000-001F-0409-0000-0000000FF1CE}
    05/09/2014 20:19:05 Rolling back package: Proof.fr-fr
    Package Proof.fr-fr was uninstalled in the chain... installing with previous feature states as part of chain rollback...
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Catalyst Package Uninstall Rollback (install)...
    Package: Proof.fr-fr
    File: C:\MSOCache\All Users\{90140000-002C-0409-0000-0000000FF1CE}-C\Proof.fr\Proof.msi
    Command Line: ADDLOCAL=MsoInstalledPackagesScopedIntl_1036,Gimme_OnDemandData,SpellingAndGrammarFiles_1036,SetupControllerFiles,FindAllWordFormsFiles_1036,TranslationFiles_1036,ThesaurusFiles_1036,HyphenationFiles_1036,SetupXmlFiles,OCR_1036 REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Successfully rolled back the configuration of package: Proof.fr-fr ProductCode:{90140000-001F-040C-0000-0000000FF1CE}
    05/09/2014 20:19:11 Rolling back package: Proof.es-es
    Package Proof.es-es was uninstalled in the chain... installing with previous feature states as part of chain rollback...
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Catalyst Package Uninstall Rollback (install)...
    Package: Proof.es-es
    File: C:\MSOCache\All Users\{90140000-002C-0409-0000-0000000FF1CE}-C\Proof.es\Proof.msi
    Command Line: ADDLOCAL=Gimme_OnDemandData,SpellingAndGrammarFiles_3082,OCR_3082,FindAllWordFormsFiles_3082,HyphenationFiles_3082,ThesaurusFiles_3082,MsoInstalledPackagesScopedIntl_3082,SetupControllerFiles,SetupXmlFiles,TranslationFiles_3082 REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Successfully rolled back the configuration of package: Proof.es-es ProductCode:{90140000-001F-0C0A-0000-0000000FF1CE}
    05/09/2014 20:19:12 Rolling back package: Office64MUISet.en-us
    Package Office64MUISet.en-us was uninstalled in the chain... installing with previous feature states as part of chain rollback...
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Catalyst Package Uninstall Rollback (install)...
    Package: Office64MUISet.en-us
    File: C:\MSOCache\All Users\{90140000-0116-0409-1000-0000000FF1CE}-C\Office64MUISet.msi
    Command Line: ADDLOCAL=Gimme_OnDemandData,SetupXmlFiles,SetupControllerFiles,MsoInstalledPackagesScopedIntl_1033 REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Successfully rolled back the configuration of package: Office64MUISet.en-us ProductCode:{90140000-0116-0409-1000-0000000FF1CE}
    05/09/2014 20:19:19 Rolling back package: Office64MUI.en-us
    Package Office64MUI.en-us was uninstalled in the chain... installing with previous feature states as part of chain rollback...
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Catalyst Package Uninstall Rollback (install)...
    Package: Office64MUI.en-us
    File: C:\MSOCache\All Users\{90140000-0116-0409-1000-0000000FF1CE}-C\Office64MUI.msi
    Command Line: ADDLOCAL=OfficeExample64bitFilesBIntl_1033,OfficeExample64bitFilesAIntl_1033,Gimme_OnDemandData,Outlook64SearchShellRegIntl_1033,ProductFilesIntl64_1033,MsoInstalledPackagesScopedIntl_1033,OneNoteToLinkedNotesIEAddin64Intl_1033,GrooveFiles64Intl_1033,SetupControllerFiles,SetupXmlFiles REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Successfully rolled back the configuration of package: Office64MUI.en-us ProductCode:{90140000-002A-0409-1000-0000000FF1CE}
    05/09/2014 20:19:20 Rolling back package: OfficeMUISet.en-us
    Package OfficeMUISet.en-us was uninstalled in the chain... installing with previous feature states as part of chain rollback...
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Catalyst Package Uninstall Rollback (install)...
    Package: OfficeMUISet.en-us
    File: C:\MSOCache\All Users\{90140000-0115-0409-0000-0000000FF1CE}-C\OfficeMUISet.msi
    Command Line: ADDLOCAL=Gimme_OnDemandData,SetupXmlFiles,SetupControllerFiles,MsoInstalledPackagesScopedIntl_1033 REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Successfully rolled back the configuration of package: OfficeMUISet.en-us ProductCode:{90140000-0115-0409-0000-0000000FF1CE}
    05/09/2014 20:19:20 Rolling back package: OfficeMUI.en-us
    Package OfficeMUI.en-us was uninstalled in the chain... installing with previous feature states as part of chain rollback...
    Resource File Manager : Converted CultureTag [en-US] to LocaleId [1033].
    Catalyst Package Uninstall Rollback (install)...
    Package: OfficeMUI.en-us
    File: C:\MSOCache\All Users\{90140000-0115-0409-0000-0000000FF1CE}-C\OfficeMUI.msi
    Command Line: ADDLOCAL=MetricConverterIntl_1033,AlwaysInstalledIntl_1033,MSTagPluginStockFilesIntl_1033,WebDiscussFilesIntl_1033,GraphicsFiltersPNGFilesIntl_1033,EquationEditorFilesIntl_1033,GraphicsFiltersEPSFilesIntl_1033,MSTagPluginNamesFilesIntl_1033,TCWP5FilesIntl_1033,CAGOffice10Intl_1033,OISFilesIntl_1033,WxpFilesIntl_1033,XDOCSEditorFilesIntl_1033,CAGFilesIntl_1033,WISPHiddenIntl_1033,CAGCat10Intl_1033,SetLanguageFilesIntl_1033,OSetupControllerIntl_1033,MsoInstalledPackagesScopedIntl_1033,TCRecoverFilesIntl_1033,SetupControllerFiles,ClviewFilesIntl_1033,GraphHelpFilesIntl_1033,ProductNonBootFilesIntl_1033,MSTagPluginPlacesFiles_1033,VisioPreviewerIntl_1033,ProductFilesIntl_1033,AceReplIntl_1033,GraphicsFiltersCGMFilesIntl_1033,GraphicsFiltersWPGFilesIntl_1033,Gimme_OnDemandData,TCWP6FilesIntl_1033,GraphicsFiltersGIFFilesIntl_1033,GRAPHFilesIntl_1033,MSTagPluginDateFilesIntl_1033,WebDriveFilesIntl_1033,LOBiFilesIntl_1033,LISTFilesIntl_1033,UICaptionsCompanionIntl_1033,SetupXmlFiles,AceFilesIntl_1033,TOOLSFilesIntl_1033,MSSOAP3Intl_1033,VBAHelpFilesIntl_1033,GraphicsFiltersPICTFilesIntl_1033,OfficeDigitalSFilesIntl_1033,VBAFilesIntl_1033,GraphicsFiltersJPEGFilesIntl_1033,QueryFilesIntl_1033,SetLanguageHelpFilesIntl_1033 REBOOT=ReallySuppress LAUNCHEDBYSETUPEXE=1 MSIRESTARTMANAGERCONTROL="Disable" SETUPEXEINSTALLUILANGUAGE=1033 SETUPINTLDLLDIRECTORY="C:\Windows\TEMP\Setup00001048\"
    MSI(INITIALIZE): '<NULL>'
    MSI(TERMINATE): '<NULL>'
    Successfully rolled back the configuration of package: OfficeMUI.en-us ProductCode:{90140000-006E-0409-0000-0000000FF1CE}
    Error attaching to OSE, error 0x00000000
    Stopping running ose
    LIS: start uncaching for download "{90140000-002C-0409-0000-0000000FF1CE}-C"
    LIS: finished uncaching for download "{90140000-002C-0409-0000-0000000FF1CE}-C"
    LIS: start uncaching for download "{90140000-003A-0000-0000-0000000FF1CE}-C"
    LIS: finished uncaching for download "{90140000-003A-0000-0000-0000000FF1CE}-C"
    LIS: start uncaching for download "{90140000-00B4-0409-0000-0000000FF1CE}-C"
    LIS: finished uncaching for download "{90140000-00B4-0409-0000-0000000FF1CE}-C"
    LIS: start uncaching for download "{90140000-0115-0409-0000-0000000FF1CE}-C"
    LIS: finished uncaching for download "{90140000-0115-0409-0000-0000000FF1CE}-C"
    LIS: start uncaching for download "{90140000-0116-0409-1000-0000000FF1CE}-C"
    LIS: finished uncaching for download "{90140000-0116-0409-1000-0000000FF1CE}-C"
    Error attaching to OSE, error 0x00000000
    Stopping running ose
    SystemRestore : Attempting to cancelling System-Restore-Point for Product [Microsoft Project Standard 2010] (with RestorePointType [0, Installed]).
    SystemRestore : Successfully cancelled System-Restore-Point for Product [Microsoft Project Standard 2010] (with RestorePointType [0, Installed]).
    Not showing completion dialog because it was not requested.
    Catalyst execution finished: 05/09/2014 20:19:25. Return code: 1603.
    PERF: TickCount=722128 Name=RunSetup Description=End function
    Can onyone enlighten me what's went wrong, and why did I get this inconsitent installation behaviour?
    Thank you very much!!!

    1603 means there is a fatal error during installation process.
    Take a look at the article below. It may help on finding cause.
    Hi Juke,
    I did do fair a bit of Googling before I started the post. I have increased the logging level on one of the machines failed on the installation. Apparently Project installation log doesn't throw the "return value 3", I think it's pointing to a particular
    updating item, anyone knows what is it?
    Microsoft Office Project Standard 2010 - Update '{35347883-0E64-45B4-88A0-1881DE05E259}' could not be installed.
    The following is the detailed installation log.
    MSI (s) (8C:B4) [20:31:33:122]: Executing op: SetTargetFolder()
    MSI (s) (8C:B4) [20:31:33:122]: Executing op: FontRegister(Title=Arial Unicode MS (TrueType),File=ARIALUNI.TTF)
    MSI (s) (8C:B4) [20:31:33:122]: SHELL32::SHGetFolderPath returned: C:\WINDOWS\Fonts
    MSI (s) (8C:B4) [20:31:33:122]: Executing op: End(Checksum=0,ProgressTotalHDWord=0,ProgressTotalLDWord=0)
    MSI (s) (8C:B4) [20:31:33:122]: Error in rollback skipped. Return: 5
    MSI (s) (8C:B4) [20:31:33:746]: Entering MsiProvideAssembly. AssemblyName: Policy.12.0.Microsoft.Office.Interop.MSProject,version="14.0.0.0000000",processorArchitecture="MSIL",publicKeyToken="71E9BCE111E9429C",fileVersion="14.0.4751.1000",culture="neutral", AppContext: , InstallMode: -4
    MSI (s) (8C:B4) [20:31:33:746]: Pathbuf: 0, pcchPathBuf: 0
    MSI (s) (8C:B4) [20:31:33:777]: MsiProvideAssembly is returning: 1607
    MSI (s) (8C:B4) [20:31:33:777]: Entering MsiProvideAssembly. AssemblyName: Policy.11.0.Microsoft.Office.Interop.MSProject,version="14.0.0.0000000",processorArchitecture="MSIL",publicKeyToken="71E9BCE111E9429C",fileVersion="14.0.4751.1000",culture="neutral", AppContext: , InstallMode: -4
    MSI (s) (8C:B4) [20:31:33:777]: Pathbuf: 0, pcchPathBuf: 0
    MSI (s) (8C:B4) [20:31:33:808]: MsiProvideAssembly is returning: 1607
    MSI (s) (8C:B4) [20:31:33:808]: Entering MsiProvideAssembly. AssemblyName: Microsoft.Office.Interop.MSProject,version="14.0.0.0000000",processorArchitecture="MSIL",publicKeyToken="71E9BCE111E9429C",fileVersion="14.0.4751.1000",culture="neutral", AppContext: , InstallMode: -4
    MSI (s) (8C:B4) [20:31:33:808]: Pathbuf: 0, pcchPathBuf: 0
    MSI (s) (8C:B4) [20:31:33:840]: MsiProvideAssembly is returning: 1607
    MSI (s) (8C:B4) [20:31:33:840]: Note: 1: 2318 2:
    MSI (s) (8C:B4) [20:31:33:840]: No System Restore sequence number for this installation.
    MSI (s) (8C:B4) [20:31:33:840]: Unlocking Server
    MSI (s) (8C:B4) [20:31:33:980]: PROPERTY CHANGE: Deleting UpdateStarted property. Its current value is '1'.
    MSI (s) (8C:B4) [20:31:33:980]: Transforming table InstallExecuteSequence.
    MSI (s) (8C:B4) [20:31:33:980]: Transforming table InstallExecuteSequence.
    MSI (s) (8C:B4) [20:31:33:980]: Transforming table InstallExecuteSequence.
    MSI (s) (8C:B4) [20:31:33:980]: Note: 1: 2262 2: InstallExecuteSequence 3: -2147287038
    MSI (s) (8C:B4) [20:31:34:011]: Product: Microsoft Office Project Standard 2010 - Update '{35347883-0E64-45B4-88A0-1881DE05E259}' could not be installed. Error code 1603. Additional information is available in the log file C:\WINDOWS\TEMP\MSI1f79e.LOG.
    MSI (s) (8C:B4) [20:31:34:011]: Windows Installer installed an update. Product Name: Microsoft Office Project Standard 2010. Product Version: 14.0.4763.1000. Product Language: 0. Manufacturer: Microsoft Corporation. Update Name: {35347883-0E64-45B4-88A0-1881DE05E259}. Installation success or error status: 1603.
    MSI (s) (8C:B4) [20:31:34:011]: Note: 1: 1708
    MSI (s) (8C:B4) [20:31:34:011]: Product: Microsoft Office Project Standard 2010 -- Installation operation failed.
    MSI (s) (8C:B4) [20:31:34:011]: Windows Installer installed the product. Product Name: Microsoft Office Project Standard 2010. Product Version: 14.0.4763.1000. Product Language: 0. Manufacturer: Microsoft Corporation. Installation success or error status: 1603.
    MSI (s) (8C:B4) [20:31:34:011]: Attempting to delete file C:\WINDOWS\Installer\5a202cf.msp
    MSI (s) (8C:B4) [20:31:34:011]: Unable to delete the file. LastError = 32
    MSI (s) (8C:B4) [20:31:34:011]: Attempting to delete file C:\WINDOWS\Installer\5a202d0.mst
    MSI (s) (8C:B4) [20:31:34:011]: Unable to delete the file. LastError = 32
    MSI (s) (8C:B4) [20:31:34:011]: Deferring clean up of packages/files, if any exist
    MSI (s) (8C:B4) [20:31:34:011]: Attempting to delete file C:\WINDOWS\Installer\5a202cf.msp
    MSI (s) (8C:B4) [20:31:34:011]: Attempting to delete file C:\WINDOWS\Installer\5a202d0.mst
    MSI (s) (8C:B4) [20:31:34:011]: MainEngineThread is returning 1603
    MSI (s) (8C:24) [20:31:34:011]: No System Restore sequence number for this installation.
    MSI (s) (8C:24) [20:31:34:011]: User policy value 'DisableRollback' is 0
    MSI (s) (8C:24) [20:31:34:011]: Machine policy value 'DisableRollback' is 0
    MSI (s) (8C:24) [20:31:34:011]: Incrementing counter to disable shutdown. Counter after increment: 0
    MSI (s) (8C:24) [20:31:34:011]: Note: 1: 1402 2: HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Installer\Rollback\Scripts 3: 2
    MSI (s) (8C:24) [20:31:34:011]: Note: 1: 1402 2: HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Installer\Rollback\Scripts 3: 2
    MSI (s) (8C:24) [20:31:34:027]: Decrementing counter to disable shutdown. If counter >= 0, shutdown will be denied. Counter after decrement: -1
    MSI (s) (8C:24) [20:31:34:027]: Restoring environment variables
    MSI (s) (8C:24) [20:31:34:027]: Destroying RemoteAPI object.
    MSI (s) (8C:48) [20:31:34:027]: Custom Action Manager thread ending.
    MSI (c) (F4:1C) [20:31:34:027]: Decrementing counter to disable shutdown. If counter >= 0, shutdown will be denied. Counter after decrement: -1
    MSI (c) (F4:1C) [20:31:34:027]: MainEngineThread is returning 1603
    === Verbose logging stopped: 7/05/2014 20:31:34 ===

  • Application crashes in Windows 7 64bit made in Labview 2010 sp1 f2 with Fault module name%3A lvrt.dll%2C version 10.0.0.4033 and exception code c0000005

    I build an application exe and then its installer along with run time environment.
    The installers instals the application correctly but when I try to execute the application, I get an error that application has crashed and Windows must close it down or search for solutions online with this additional information for the crash. 
    Problem signature:
    Problem Event Name: APPCRASH
    Application Name: AGMS.exe
    Application Version: 1.3.0.0
    Application Timestamp: 4c24e8f5
    Fault Module Name: lvrt.dll
    Fault Module Version: 10.0.0.4033
    Fault Module Timestamp: 4c9273f4
    Exception Code: c0000005
    Exception Offset: 00005310
    OS Version: 6.1.7601.2.1.0.256.1
    Locale ID: 1033
    Additional Information 1: 0a9e
    Additional Information 2: 0a9e372d3b4ad19135b953a78882e789
    Additional Information 3: 0a9e
    Additional Information 4: 0a9e372d3b4ad19135b953a78882e789
    Read our privacy statement online:
    http://go.microsoft.com/fwlink/?linkid=104288&clcid=0x0409
    If the online privacy statement is not available, please read our privacy statement offline:
    C:\Windows\system32\en-US\erofflps.txt
    I am using labview 2010 sp1 32 bit on a 64-bit machine, with the following specs
    Operating System: Windows 7 Home Premium 64-bit (6.1, Build 7601) Service Pack 1 (7601.win7sp1_gdr.130318-1533)
    Language: English (Regional Setting: English)
    System Manufacturer: Dell Inc.
    System Model: Dell System XPS L502X
    BIOS: Default System BIOS
    Processor: Intel(R) Core(TM) i7-2630QM CPU @ 2.00GHz (8 CPUs), ~2.0GHz
    Memory: 8192MB RAM
    Available OS Memory: 8106MB RAM
    Page File: 3457MB used, 12753MB available
    Windows Dir: C:\Windows
    DirectX Version: DirectX 11
    DX Setup Parameters: Not found
    User DPI Setting: Using System DPI
    System DPI Setting: 96 DPI (100 percent)
    DWM DPI Scaling: Disabled
    DxDiag Version: 6.01.7601.17514 32bit Unicode
    The exe /application runs fine on my PC but when I try to run it on another PC it crashes. The other PC has similar specs as given below
    Operating System: Windows 7 Ultimate 64-bit (6.1, Build 7601) Service Pack 1 (7601.win7sp1_gdr.140303-2144)
    Language: English (Regional Setting: English)
    System Manufacturer: LENOVO
    System Model: HuronRiver Platform
    BIOS: Default System BIOS
    Processor: Intel(R) Core(TM) i3-2330M CPU @ 2.20GHz (4 CPUs), ~2.2GHz
    Memory: 4096MB RAM
    Available OS Memory: 4010MB RAM
    Page File: 1359MB used, 6658MB available
    Windows Dir: C:\Windows
    DirectX Version: DirectX 11
    DX Setup Parameters: Not found
    User DPI Setting: Using System DPI
    System DPI Setting: 96 DPI (100 percent)
    DWM DPI Scaling: Disabled
    DxDiag Version: 6.01.7601.17514 32bit Unicode
    I tried another machine, 64 bit of course, as I want to deploy my application on a 64bit PC, but still got the same problem.
    This other machine was from HP, iCore 3 (4 CPUs) 2.2GHz, 4GB RAM and running Windows Professional 64 bit.
    Now as I see it, it could be a Run-time environment mis-match error.
    For this I tried installing a 64 bit LVRTE from NI, but still no sucess.
    I checked DEP, for all 3 PCs and it was set to the following
    Turn on DEP for essential Windows programs and services only (first option).
    I am confused. I can not find a solution for this and it is really frustrating.

    But I am assuming that when I make the installer, the 32-bit Run Time Engine is appened with the installer, as show below
    Since from the picture you can see its including the support installers from '\Program Files (x86)\'
    The application runs queries to fetch data from database in SQL server 2008, and for that I am using a Microsoft SQL Native Client 2008 R2 64 bit ( this is the only version that installs on either PC, even the one on which I developed my LV Application).
    I am not using any driver, only toolkits for reports - and for that I un-checked the "Remove unused polymorphic VI instances" when making the executable, otherwise LV throws up an exception that share variable are not being included.
    Yes I did reboot every time after I ran the installation.
    Still getting the same error.

  • Activating Project Professional 2010 after a crash

    hi there:-
    I am looking to reactivate/reinstall Project Professional 2010 after a crash. I have a product activation code having downloaded the software online (no disks). What do I need to do?
    Much obliged
    Tom

    Tom,
    It should be pretty straightforward. I assume you saved a copy of the .img file you downloaded to a location that was safe from your crash. Without that you're probably out of luck.
    Just re-install from the .img file and when the installation gets to the part for activation, go ahead and activate it.
    Hope this helps.
    John

  • Error when trying to migrate project from labwindows 2010 SP1 over to VS2008

    I'm sure I've been successful back with this when running CVI 8.5 and VS2003 / 2005, but I keep gettin the following error when trying to do this with my current configuration. What am I missing?
    See attached image
    Regards
    Gavin
    Attachments:
    CVI-VS error.JPG ‏29 KB

    Not recently, but what I would say is that CVI 2010 SP1 was installed after my VS2008 installation, so it ought to be in the right order.... When I get a moment I'll reinstall the CVI runtime and see what happens. Its not critical that I get this fixed, as the project in question is so small, and as the important parts are almost competely ANSI C, it should be really easy to reconstruct in C# anyway. I'll let you know what happens anyway

  • Do I *really* need a Service Connection Point in AD to complete a Project Server 2010 SP2 installation?

    Hi all,
    I have installed Project Server 2010 SP2 and run psconfig.exe
    PSCONFIG is failing because it cannot set up a Service Connection Point in AD. I've checked in AD and the contains 'Microsoft SharePoint Products' does not exist. All the resolutions I can find suggest adding the container into AD.
    The issue I have is that I have no control of the AD, and adding containers will take lengthily negotiation.
    Is there any way of completing the installation and getting my site back without adding the container into AD?
    Thanks in advance.

    other solutions
    1) check timer service see if it is running
    http://www.jonthenerd.com/2011/06/30/sharepoint-2010-sp1-upgrade-error-unable-to-create-a-service-connection-point-in-the-current-active-directory-domain/
    2) check UAC (and the rest of the technet answers - some are listed below)
    http://social.technet.microsoft.com/Forums/en-US/94a8bb64-e0ea-493f-8e29-01347b1fc6c7/psconfig-fails-failed-to-upgrade-sharepoint-products
    3) My workaround:I
    run once again the command „PSConfig.exe -cmd upgrade -inplace b2b -force -cmd applicationcontent -install -cmd installfeatures“  in
    the “Bin” Folder as an administrator console session.In the moment I saw the staus “Configurationtask 5 of 6 is executed”
    I start to run the command “net start SPTraceV4 & net start SPWriterV4 & net start SPAdminV4 & net start SPSearch4 & net start SPTimerV4” in a parallel administrator console session and after that the configuration task finished successfully.
    http://social.technet.microsoft.com/Forums/en-US/94a8bb64-e0ea-493f-8e29-01347b1fc6c7/psconfig-fails-failed-to-upgrade-sharepoint-products
    4) Try running the psconfig.exe command a second time
    5) had the same issue and called Microsoft support.  Here is the fix:
    Stop the "SharePoint 2010 Timer" service
    Delete ONLY the xml files from C:\ProgramData\Microsoft\SharePoint\Config\216f8013-b78b-4e5b-8631-3a5f4c7277e8
    Note: Do NOT delete the cache.ini file in this folder
    Edit cache.ini and change to "1"
    Start "SharePoint
    2010 Timer" service
    Run psconfig again:  PSConfig.exe -cmd upgrade -inplace b2b -wait -force
    6) Initially I tried http://support.microsoft.com/kb/2009272 but
    it did not help (I re-implemented later).
    I re-registered the DLL’s as perhttp://social.technet.microsoft.com/Forums/da/winservergen/thread/b4bd0deb-45d0-4661-8c50-a2b45db41103 from
    NareshD.  I do not believe this is necessary unless there is a corruption in the system but I am noting here just
    in case.
    I tried to run The PSConfig but it was failing:  I
    had to do the following in order to make it finish successfully:
    (from same page at http://social.technet.microsoft.com/Forums/en-US/smallbusinessserver/thread/94a8bb64-e0ea-493f-8e29-01347b1fc6c7/)
    On the migrated SBS2011 PSCDiagnostic Log I found no entry to detect or start the services SPWriterServiceInstance and SPTimerServiceInstance.
    I run once again the command „PSConfig.exe -cmd upgrade -inplace b2b -force -cmd applicationcontent
    -install -cmd installfeatures“ in the “Bin” Folder as an administrator console session.
    In
    the moment I saw the status “Configuration task 5 of 6 is executed” I
    start to run the command “net start SPTraceV4 & net start SPWriterV4 & net start SPAdminV4 & net start SPSearch4 & net start SPTimerV4” in a
    parallel administrator console session and after that, the configuration task finished successfully.  (I
    just opened another cmd window and copy/paste the sequence below when I saw the status “Configuration Task x of y” on the screen:
    net start SPTraceV4 
    net start SPWriterV4 
    net start SPAdminV4 
    net start SPSearch4 
    net start SPTimerV4
    -Note SPSearch4 is disabled in our system…
    Very awkward but it worked…
    I implemented http://support.microsoft.com/kb/2009272 again.
    Backup started working with no errors.

  • Project Server 2010 (SP1) - Project not loaded in Project Professional

    Hi,
    We are currently facing an issue with a Project Server 2010 SP1 implementation.
    When users are trying to open a plan within Microsoft Project Professional as from the Project Center, the client is loading and is opening only "Project 1". The selected project is not opening.
    If Microsoft Project Professional is already opened, the selected project is rightly loaded.
    Nothing relevant within the Events Viewer or within the ULS log files.
    Thanks for you help.

    Delete browser history, add PWA site as trusted site.Rename global.mpt file and try again
    Hrishi Deshpande Senior Consultant

  • Why does Project 2010 Pro crash on cut and paste operation, among many other problems?

    I guess my question has more to do with this: I'm trying to find a hotfix, patch or update for this. Can you advise?
    Thanks,
    Aldo

    Hi, Mike,
    Thank you for your very informative reply. Please accept the comments below in the interest of understanding the problem a little better. I will read your articles and comment on them, if applicable.
    What I think you are suggesting is basically for me to provide more information. Perhaps you could advise on how my concern could best be addressed. It's a simple matter of copying and pasting lines until it crashes, which I can't understand why I would
    want to avoid, particularly when the actions of the interface clearly support it. So, from a UI design perspective I have to ask, if this is a valid task for an Excel spreadsheet why is it not for a Project spreadsheet?
    Please bear in mind that the issue here is not related to the effective use of the product, but quite plainly why doesn't this stuff work out of the box on a simple paste operation?
    By "Adding", in my previous comments, I mean go to the "Project" ribbon, and select the "Subproject" button. Following is a very detailed set of steps.
    1. Open Microsoft Project 2010 Professional, in either 64 bit or 32 bit mode.
    2. About Microsoft Project displays (14.0.4751.1000) MSO (14.0.4760.1000), by going to the quick access tool bar, selecting "Customize quick access tool bar", selecting "More commands", selecting from the pull-down "Choose commands
    from" the option "All commands", and then the "About" option in the list view right below it. Press the "Add" button in the middle of the form. Press the OK button. You will see the about button on the quick access bar. Press
    the button to see what version of the software this is. If you need additional information to help troubleshoot the issue, please let me know.
    3. On the currently open default blank project, first save the project by pressing the save button on the quick access tool bar. I've named this file "Project1.mpp", and the physical file location is the Documents folder on Windows 7. The task
    name becomes "Task 1". I then click outside the row.
    4. Select the entire row by clicking on the number column to the left of the spreadsheet. Press the "C" key while holding down the "Control" key. Now select the next row and press the "V" key, while holding down the "Control"
    key. Do it again if it makes you feel better.
    5. Press Ctrl-S to save. Now close the project by clicking on the "File" menu and selecting the close button.
    6. Create a new Project file, by selecting "File", then "New", then "Blank project", then "Create". Repeat steps 3 through 5 but this time name the project "Project2.mpp"
    7. Click on an empty row on the spreadsheet. This will serve as the placement location of the sub-project. Click on the project tab, Click on the  "Subproject" button on the left of the ribbon and select Project1.mpp. Your original Project1
    will appear as a sub-project. Select a row in this subproject and copy and paste this row onto the previous project. Everything should work fine and your rows should paste.
    8. Now try pasting onto the same subproject on the row below. The application crashes.
    Thanks again for your reply,
    Aldo

  • Project 2010 Crashes

    Hi,
    I've been having this issue to export to PDF from Project 2010 (Std Ed - 32 bit). It just hangs and no response for ever (not responding mode)
    I searched for fixes, but no luck so far and i also contacted vendor who purchased the software for our company and he does not seem to answer it. Lost all my hope and i run to people when ever i need to export to PDF version.
    As i last resort, i'm here..could someone suggest how to fix this? Do i've to install any Service pack?
    I tried the options that MVP Sapna mention in a thread and no luck - https://social.technet.microsoft.com/Forums/en-US/f2a7c40d-c5b4-4194-97cc-addc5703112f/project-professional-2010-crashes-when-saving-to-pdf-format?forum=projectprofessional2010general
    Appreciate your speedy response on this.

    Hi Shyam,
    First of all, if not done, I'd suggest you to install the
    SP2. Then try to repair Project from the control panel. Finally, does it happen for all projects, or just specific project(s)?
    Hope this helps,
    Guillaume Rouyre, MBA, MVP, P-Seller |

  • Ms project 2010 is crashing again and again due to different activities .

    Many Ms project users of our company facing below issue:
    We also have service pack 1 installed as well as Cummulative Update (14.0.6137.5000).
    When they change the date of any task or enter new task. Ms Project 2010 is crashed or any other activity. e.t.c
    Wheather Ms Project is connected with Project Server or we are doing locally and open new project.
    Is this microsoft bug or what is the solution of this .
    If we check on google . There are many causes of this issue on net and many solutions.

    John.Eddie,
    In addition to Dale's advice on SP2, try following steps
    Close Project Pro
    Navigate to following path  and rename existing Global.Mpt file
    C:\Users\{User ID}\AppData\Roaming\Microsoft\MS Project\14\1033
    Re-launch Project pro to validate the behavior.
    Hrishi Deshpande Senior Consultant

  • I need help linking Microsoft SDK to My visual studio 2010 sp1 project?

    I need help linking Microsoft SDK to My visual studio 2010 sp1 project?
    Hi, I'm on windows 8.1 and I'm getting a lot of Direct x sdk errors every time I try to debug or release a project. Please help me I'm lost trying to fix's this, thanks.

    Hi programmerblizz,
    According to your description, could you please tell me which kind of project you try to debug or release? Is it a c++ project or other?
    If it is a c++ project, I suggest you can refer the following thread check your issue in your side.
    Reference:
    http://stackoverflow.com/questions/26303922/directx-9-cannot-find-the-include-libaries
    If no, please tell me more detail message about your issue.
    Best Regards,
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • Any Problem Running Office 2010 SP2 with Project Server 2010 SP1?

    We are running Project Server 2010 SP1 April 2013 CU and the desktop clients have now been upgraded to SP2 October 13 CU. We are having issues with projects in local cache showing as checked out when they are not actually checked out on the server. I was
    wondering if it is problematic to run the desktop client on a newer service pack than the server and if it could cause this type of issue?

    Hello, Aaron.
    The answer is YES, you'll probably have some issues.
    I would recommend:
    Downgrade clients to match Server's version
    Upgrade Server to SP2+October '13 CU
    And my preferred:
    Upgrade Server and clients to SP2 + '14 April CU

  • OneNote 2010 SP1 (from Pro Plus 32bit MAK Volume Download) Activation Issue

    Hi There,
    I have been working on Microsoft Office App-V Sequencing and have successfully managed to sequence both Project Pro 2010 SP1 and Visio Pro 2010 SP1.
    We have had an external company handle the sequencing for the main Office Pro Plus 2010, however they have since informed us that it didn't include either OneNote or Office Picture Manager.
    I have been working on trying to sequence OneNote 2010 out of the Office Professional Plus 32 bit 2010 SP1 MAK Volume Download following the steps in the Microsoft Guide as well as StealthPuppys' guide. Basically:
    1) Extract the iso to a folder
    2) Install the Microsoft Sequencing Kit on the sequencing machine
    3) Install both x64 and x86 App-V Deployment Kits
    4) Go to the x64 (64 bit sequencing machine) through command prompt and do the 'msiexec /i OffVirt.msi ADDLOCAL=OSpp,OSpp_Core,OSppWoW64 PIDKEYS=XXXXX-XXXXX-XXXXX-XXXXX-XXXXX USEROPERATIONS=1'
    5) Start the sequencer, add the Exclusion items for the Office Software Protection Plan and Windows
    6) Carry out a custom install selecting only OneNote and the Office Shared Files to install
    7) Finish the sequence and copy the programs to the shared drive
    8) Deploy the application
    9) On the target machine which has the Deployment kit added command prompt to the folder and run ''msiexec /i OffVirt.msi ADDLOCAL=OSpp,OSpp_Core,OSppWoW64 PIDKEYS=(Project MAK);(Visio MAK);(Office MAK) USEROPERATIONS=1'
    10) Download the packages through the App-V Tool
    OneNote launches but then freezes saying 'Microsoft Office Professional Plus 2010 cannot verify the licence for this product. You should repair the Office program by using Control Panel' and the program force closes.
    I have also tried using a custom config.xml to during  the sequencer (which I did for both Visio and Project) with the first line set to <Configuration Product="ProPlus"> and also tried "OneNote" and at the installer section
    used an elevated command prompt to navigate to the office folder and run 'setup.exe/config c:\office\config.xml' and this also did not work.
    This and Office Picture Manager are the last of the App-V programs left to sequence for deployment in a new SOE for a client so any help would be greatly appreciated.
    Kind Regards
    Joseph Wybraniec
    Techstream Solutions

    You will need to open the Office package and add OneNote. Adding OneNote as a separate package won't be supported or work as expected.
    Please remember to click "Mark as Answer" or "Vote as Helpful" on the post that answers your question (or click "Unmark as Answer" if a marked post does not actually
    answer your question). This can be beneficial to other community members reading the thread.
    This forum post is my own opinion and does not necessarily reflect the opinion or view of my employer, Microsoft, its employees, or other MVPs.
    Twitter:
    @stealthpuppy | Blog:
    stealthpuppy.com |
    The Definitive Guide to Delivering Microsoft Office with App-V

  • Global Templates Corrupted in Project 2010

    Has anyone had an issue with project templates, associated with EPT's, causing Project Pro 2010 to crash whenever the drop-down selection on a column (field) is chosen?
    I am running Project Server/Pro 2010 SP1 patched to Oct 2012.
    I have 3 templates that are similar (small, medium, large).  The medium and large when opened as templates were fine, so I simply saved them back and they are working fine.  The small one was corrupted whenever the column drop-down was clicked. 
    I opened another version of the small template from my lab system (same content as production) and saved it to production and all is good.  I am at a loss to figure what happened prior to this exercise. I saved a copy of the corrupted small template and
    the corrupted projects for further examination.  Any ideas?  The fix for the projects with the corrupted template requires saving all the PWA and Project Site information, deleting the project and its associated site and starting over from scratch. 
    Those with actual hours will take even longer.  What a mess.
    Update 4/29/14 -
    Regarding the corrupted template and project files that occurred recently, Microsoft has stated that this behavior is fixed after installing the April 2014 CU. 
    I will verify this when the April CU is applied to the test machine in our lab. 
    The cause of the crashing was related to a null setting in the filter-by and group-by settings.  A null is not a setting that can be selected, so I am unclear as to how it got that way in the template.
     There is no answer as to why the selections are null and it cannot be corrected. 
    This is a bug.

    Dinesh,
    I am painfully aware of the fix to the corruption.  I have removed all the corrupted templates and replaced them with non-corrupted ones.  I am now working to fix 32 projects that have the corrupted template.  Some of these 32 have actual
    hours posted making the task even more time consuming.
    No I did not initiate a ticket with Microsoft.  My experience after working through several bug tickets with them it is that it takes a lot of effort to provide them what they need (problem description, creating compressed copies of all 4 databases,
    uploading, fielding calls from the support techs, then dealilng with the folks they hand off to, then getting acknowledgement that it is a bug and will be addressed by the development team and placed in a private fix or CU in an upcoming cycle).  In the
    meantime, I have projects to fix!  I realize that we are not up-to-date on CU's and SP's.  I am working on that now.
    Thanks.

Maybe you are looking for

  • Voice memos do not delete (1 hr of recordings)!

    Where I find these "undeleted" voice memos.  When I connect iPhone, itunes opens and on the top right I click iPhone. There are 10 tabs in total (Summary - Info - Apps - Tones - Music - Movies - TV Shows - Books - Photos - On This iPhone). I click On

  • More than one service Performer per sales order position

    Hallo ByD community We are using service type "Service - time and material" in our sales orders and we are using the integrated time recording in the self-service (time sheet) to track actual times for an sales order. For that you have to assign a se

  • N8 Screen Issue

    I bought an N8 shorty after it was released.  Slowly over the past three or four months, the touch screen detection has been slowly becoming inaccurate.  The phone detects that I am pressing slightly above where I am actually pressing.  Is there any

  • Adapter Factory Question

    Hi, Is it possible to populate a Child Process Form using Adapter Factory ? For example: - in the User Profile I have defined a UDF , GroupWise alias - when this field is updated, I would like to fire a trigger that will modify the UD_NGW_NICK child

  • Really Strange Airport Problem...Can Anyone Help?

    We have 3 Macs in the house and two Xboxes using Airport. Everything works fine. Tonight, for some bizarre reason, two of the Macs lost their connection to the home Airport network. The Xbox still connects fine (and is the farthest away!), the Macs s