Has anyone used a S-series PXI-6143 DAQ to take encoder position measurements? I believe there are 2 counters available, if you have any examples of how to access and read from these counters it would be greatly appreciated.

Hi Bentup,
Measuring a quadrature encoder on your device is actually going to be a bit different than on an M series device.  The STC-2 chip, which is used in the M series, allows for A and B inputs specifically for encoder signals (used in the Angular Encoder task).  The original STC-1 chip which is used in E series and most S series boards (including your 6143) does not have these same inputs.  Instead, you may must a Count Digital Events task (taking advantage of the up/down line of the counter).  The Angular Encoder task is not supported on STC-1 devices.
The article that lab_boy linked earlier actually mentions how to use an encoder with an E series device once you scroll down a bit (here's the link again).  This same procedure should apply to your S series--connect the A output of your encoder to the source of the Counter (this is the signal that you are counting).  Connect B to the up/down line of the counter (P0.6 and P0.7 for counter 0 and 1 respectively). 
The downside with this method is that it is more susceptible to vibrations or noise on the encoder lines. If this is a problem for you, you can look into an external encoder conditioner like the one mentioned in the article.  I hope this helps!
Best Regards,
John
John Passiak

Similar Messages

  • Quadrature encoder counter with 8 channels

    Hi,
    I need to acquire the signals (A and B) of four quadrature encoders. The signals have a maximum frequency of about 5kHz and should be read out with about 100 Hz. Is there a device that fulfils these requirements? It seems that a frequency of 5kHz is no problem since e.g. the USB-6008 has a counter for frequencies up to 1 MHz. However, I can't find a simple low-cost device that provides several counters. Does anyone know such a device with 4 or 8 counters?
    No other analog or digital channels are necessary, but a USB connection and Matlab support would be ideal.
    Thanks in advance.

    Depending on your definition of low-cost, the 9171+9401 might suit your needs:
    4 counters capable of quadrature encoder measurements (the single counter on the 6008 only does simple edge counting).
    USB connection.
    MATLAB support via the Data Acquisition Toolbox (according to their website).
    I don't believe NI currently has any other option that meets these requirements at a lower cost.  If USB isn't mandatory, you could also consider the PCIe-6612 which provides 8 counters.
    Best Regards,
    John Passiak

  • How to find the year ago measure with out using time series functions

    hi all
    is there any way to find year ago sales with out using time series functions like ago
    Thanks
    Sreedhar

    Hello Madan,
    Thanks for the reply.
    It still doesn't consider the product into account.
    My columns are as below
    Prod Week End DATE Current Sales Prior Sales % Change
    A 12/4/2010 100 0
    A 12/11/2010 200 100
    A 12/18/2010 300 200
    B 12/4/2010 400 300(this value is not for prod B, i want this to b 0 aswell. But we get product A's last sale amount)
    Is there any way this can be done. I have tried evaluate,MSUM.
    I cannot build a time dimension as all I have is a view.
    Thanks,
    Deep

  • Can we lock 80 MHz timebase to PXI_CLK10 on PXI-6220 M Series DAQ?

    I am using PXI-6220 to measure Frequency/Period of 32768 Hz clock signal, accuracy is very important. I have provided signal to measure on Gate input of Ctr 0 (PFI 9). I am using 80 Mhz Timebase. I want to Lock PLL to PXI back plane 10 MHz reference (PXI_CLK10) which in turn is locked onto the 10 MHz reference via PXI-5600 on Slot 2 (External 10 Mhz standard is connected). so far I don't see a way to lock PLL to PXI_CLK10. Is that possible at all? see the image attached to this message.
    Attachments:
    M Series DAQ Question.png ‏62 KB

    Hello Abhatti,
    Based on the diagram that you have attached, the M-Series card can PLL to a higher accuracy clock such as the PXI Clock_10.  The way to configure this change using the DAQmx driver is route the signals using the DAQmx Timing RefClk.Src Timing property node.  Once you place down this property node, and specify the RefClk.Src attribute, you select the PXI-Clk10 as your reference clock source.  This will discipline the 80 MHz Timebase of the DAQ card to the 10 MHz reference clock of the PXI chassis.  Which chassis are you using?  Also, how have you PLL'ed the 10 MHz backplane clock to the PXI-5600 Downconverter?
    Michael L.
    Applications Engineer
    National Instruments

  • TC measurements with PXI 4351 DAQ Card

    (I am using version 6i of LabVIEW). I am trying to create a VI that will use a PXI 4351 Card with a TBX-68T to take 4 thermocouple continuous measurements. I am also acquiring 8 voltages with a 6030E and TBX-68 and writing them to a file. My voltage data acquisition is modeled after "Buffered Continuous Analog Input.vi" I would like to aquire voltages and temperatures in the same vi, but using different devices and accessories. (I need a higher frequency for the voltage acquisition, and more precision with the temperatures). Is there a subvi I can use to collect the temperature data in the same vi as my voltage? I don't want the thermocouple DAQ to interfere with the voltage DAQ, either.
    I tried the NI435x thermocouple.vi
    but I couldn't get the Built-in Cold Junction Sensor to work or figure out how to combine it with my exisiting voltage acquisition. I also got NaN for my readings, and I checked the wire connections in all the sub vi's as suggested by another solution.
    Any comments would be great. Thanks in advance.

    Claudia-
    Thanks for the response.
    Regarding the CJC- When I switch it on, the temperature readings I get are very random, roughly negative 1 degrees. (I am operating right now at room temperature, and will be using J-type TC's to measure ~43 degrees C). Also, when I use the built-in CJC, the aquisition rate seems to slow down considerably. When I use the "user specified" everything seems to be ok, including the aquisition rate.
    I measured the resitance of the Thermistor on the TBX-68T and it was about 5000 Ohms, as expected.
    Just to make sure: When using the TBX-68T, do I need to hard-wire a thermocouple to Channel 1/auto-zero and another to channel 0/CJC? Because I connected a TC to channel 0 right now, but I wasn't 100%
    sure.
    I've attached my main vi and two sub vi's that I am using for the voltage aquisition part of my project. (Note:the current measurements are just voltage measurements multiplied by the recipricol of the resistance it was measured across, ie. 10).
    I would like to keep this file as is because it writes to a file exactly the way I want it to. I'd like to have the temperature aquisition with the 4351 in the same vi as the 6030E so that they both stop and start at the same time. I am just not sure how and where to log the temperature data since there will be fewer data points than the voltage data. Any suggestions? Should I write two separate files? can I somehow append them?
    Thanks again. Hope to here from you soon.
    Attachments:
    EBlackMainDAQ.vi ‏107 KB
    Save_Data8.vi ‏45 KB
    Build_String_Array5.vi ‏33 KB

  • Frequency response measurements with pxi-5922

    I’ am using signal express and the pxi-5922 digitizer together with the AWG pxi-5441 to analyse the frequency response of a buffer amplifier. See the attached signal express file. Many different ways to measure the frequency response have been tried and this is the best I came up with. It is basically two tone extract steps in a sweep loop. But I’ am still uncertain if this is the best way to do this kind of measurement. The fact that the detected frequency differs between the two channels worries me, even when the two channels of the pxi-5922 are looped.  Is there a more accurate way to determine the frequency response?
    Best wishes
    Stefan Johansson, SP
    Attachments:
    sweep.JPG ‏397 KB
    Frequency Sweep funkar.seproj ‏81 KB

    Claudia-
    Thanks for the response.
    Regarding the CJC- When I switch it on, the temperature readings I get are very random, roughly negative 1 degrees. (I am operating right now at room temperature, and will be using J-type TC's to measure ~43 degrees C). Also, when I use the built-in CJC, the aquisition rate seems to slow down considerably. When I use the "user specified" everything seems to be ok, including the aquisition rate.
    I measured the resitance of the Thermistor on the TBX-68T and it was about 5000 Ohms, as expected.
    Just to make sure: When using the TBX-68T, do I need to hard-wire a thermocouple to Channel 1/auto-zero and another to channel 0/CJC? Because I connected a TC to channel 0 right now, but I wasn't 100%
    sure.
    I've attached my main vi and two sub vi's that I am using for the voltage aquisition part of my project. (Note:the current measurements are just voltage measurements multiplied by the recipricol of the resistance it was measured across, ie. 10).
    I would like to keep this file as is because it writes to a file exactly the way I want it to. I'd like to have the temperature aquisition with the 4351 in the same vi as the 6030E so that they both stop and start at the same time. I am just not sure how and where to log the temperature data since there will be fewer data points than the voltage data. Any suggestions? Should I write two separate files? can I somehow append them?
    Thanks again. Hope to here from you soon.
    Attachments:
    EBlackMainDAQ.vi ‏107 KB
    Save_Data8.vi ‏45 KB
    Build_String_Array5.vi ‏33 KB

  • Troulbe in measurement quadrature encoder with 6601.

    Hi,
    We are trying to measure position with 6601. The frequency of quadrature encoder is from 100Hz to 8MHz. Now, we connet the A,B and Z channel directly to counter . Using the example in CVI, we change the filter to 100ns and use x4 mode. It works perfect at low frequency.
    The problem is when the frequency of encoder is higher than 2MHz, the accuracy decreases greatly. I'd like to know about following:
    1.Can 6601 do the previous task enough? Or I must change to use 6602.
    2.If 6601 is available, is there any way to increase measurement accuracy ?(in software or wire connection )

    Jimmy,
    You would need to specify what type of accuracy you are looking for, which is pretty much dependant on the type of operation you are performing. You could be looking to timestamp your encoder positions or you could also be looking to perform position/angle tracking over time. You could also be performing single point vs. multiple point (buffered) operations. You could mention which one of the CVI examples you are using and that could give an idea of the type of operation you are performing.
    The NI-6601 is able to perform quadrature encoder measurements and the only limitations you can have in regards of frequency are the filtering parameters (if you use filtering) and the actual maximum timebase of the board (20 MHz).
    Please keep in mind that by ena
    bling filtering at 100 ns you are only guaranteeing that pulses with widths of 100 ns or longer are not being filtered out. This limits your encoder phase frequency to around 5 MHz. (Each encoder period has a 50% duty cycle, therefore the pulse duration is half the encoder period). You can refer to the board�s manual for more information on filtering.
    We would have to know the following in order to provide further help:
    a) Type of operation being performed
    b) Specific example you were using
    c) Type of accuracy you were looking for
    d) Range of accuracy you needed on your measurement
    Regards
    Alejandro Asenjo
    Applications Engineer
    National Instruments

  • Quadrature encoder with PCI-6259 DAQ board (driver for QNX)

    where can I find any example for connecting Quadrature Encoders with M Series DAQ Boards ?
    The only more or less suitable example I found in nimseries DDK, is
    "Count pulses from an external source using an external signal to control
    the count direction" (nimseries\Examples\gpctex2.cpp).
    But this example is not working correctly with Quadrature Encoders
    (encoders with  two shifted on 90 degrees phases A&B).
    i.e. in case of using this example code I get some extra count while encoder is on vibrant motor
    what means enums
    typedef enum {
           kG0_Up_DownHardware          = 2,
           kG0_Up_DownHardware_Gate     = 3,
    } tG0_Up_Down;
    and
    typedef enum {
           kG0_Encoder_Counting_ModeId          = 1,
    } tId;
    in (nimseries\ChipObjects\tTIO.h) ?
    What initalization procedure I need to work with Quadrature Encoders?
    I have PCI-6259 DAQ device
    and I'm writing programm under QNX6 operating system

    Hello alexey_3269,
    If you want to read a quadrature encoder start with gpctex1.cpp and follow the thread.
    I give you my code:
    BEGIN CODE
    ==========
    boardGpct->G0_Mode.writeG0_Load_Source_Select(tTIO​::tG0_Mode::kG0_Load_Source_SelectLoad_A);
    boardGpct->G0_Load_A.writeRegister(InitialCount);
    boardGpct->G0_Command.writeG0_Load(1);
    boardGpct->G0_Load_B.writeRegister(0);
    boardGpct->G0_Load_A.writeRegister(0);
    boardGpct->G0_Input_Select.setG0_Source_Select(9); //see above for choices, PFI8=9, 100 kHZ=18
    boardGpct->G0_Input_Select.setG0_Source_Polarity(1​); //0=CCW, 1=CW
    //If using 80 MHz timebase
    boardGpct->G0_MSeries_Counting_Mode.writeG0_MSerie​s_Alternate_Synchronization(1);
    boardGpct->G0_MSeries_Counting_Mode.setG0_MSeries_​Encoder_Counting_Mode(3);  //3 for X4 encoder counting
    boardGpct->G0_MSeries_Counting_Mode.flush();
    //Enable Input Pins
    boardGpct->G0_MSeries_ABZ.setG0_A_Select(9);  //PFI8=9,
    boardGpct->G0_MSeries_ABZ.setG0_B_Select(21); //PFI10=21
    boardGpct->G0_MSeries_ABZ.setG0_Z_Select(10); //PFI9=10 
    boardGpct->G0_MSeries_ABZ.flush();
    boardGpct->G0_Mode.setG0_Gate_Polarity(1); //invert=1
    boardGpct->G0_Mode.setG0_Output_Mode(tTIO::tG0_Mod​e::kG0_Output_ModePulse);
    boardGpct->G0_Mode.setG0_Loading_On_Gate(tTIO::tG0​_Mode::kG0_Loading_On_GateNo_Reload);
    boardGpct->G0_Mode.setG0_Loading_On_TC(tTIO::tG0_M​ode::kG0_Loading_On_TCRollover_On_TC);
    boardGpct->G0_Mode.setG0_Gating_Mode(tTIO::tG0_Mod​e::kG0_Gating_ModeLevel_Gating); //kG0_Gating_ModeGating_Disabled
    boardGpct->G0_Mode.setG0_Gate_On_Both_Edges(tTIO::​tG0_Mode::kG0_Gate_On_Both_EdgesBoth_Edges_Disable​d);
    boardGpct->G0_Mode.setG0_Trigger_Mode_For_Edge_Gat​e(tTIO::tG0_Mode::kG0_Trigger_Mode_For_Edge_GateGa​te_Starts_TC_Stops);
    boardGpct->G0_Mode.setG0_Stop_Mode(tTIO::tG0_Mode:​:kG0_Stop_ModeStop_On_Gate);
    boardGpct->G0_Mode.setG0_Counting_Once(tTIO::tG0_M​ode::kG0_Counting_OnceNo_HW_Disarm);
    boardGpct->G0_Mode.setG0_Reload_Source_Switching(t​TIO::tG0_Mode::kG0_Reload_Source_SwitchingAlternat​e);
    boardGpct->G0_Mode.flush();
    boardGpct->G0_Command.setG0_Up_Down(tTIO::tG0_Comm​and::kG0_Up_DownHardware); //kG0_Up_DownSoftware_Down
    boardGpct->G0_Command.setG0_Bank_Switch_Enable(tTI​O::tG0_Command::kG0_Bank_Switch_EnableBank_X);
    boardGpct->G0_Command.setG0_Bank_Switch_Mode(tTIO:​:tG0_Command::kG0_Bank_Switch_ModeGate);
    boardGpct->G0_Command.flush();
    boardGpct->Interrupt_G0_Enable.setG0_TC_Interrupt_​Enable(0);
    boardGpct->Interrupt_G0_Enable.setG0_Gate_Interrup​t_Enable(0);
    boardGpct->Interrupt_G0_Enable.flush();
    END CODE
    ========
    I hope this code is appropriate to you.
    FV1234

  • Do I need extra logic circuit for quadrature encoder using M-series DAQ PCI-6221?

    Hi,
    I understand that extra logic circuit, say quadrature clock converter LS7083/7084, is needed to enchance the reliability or integrity of the data for E-series board DAQ in accordance to application note: AN084.
    This is due to the vibration/jitter of the motor during running.
    Currently, I'm using M-series PCI-6221.
    Is it this new model itself can eliminate to construct this extra circuit?
    Coz I observed error is accumulating after motor rotating certain period of time. It defintely affect the control performance.
    Other than using hardware, can we use software to eliminate/mitigate the error?
    Please enlighten me. Thanks.
    Best regards,
    IANES

    Hello,
    The ap note you are referring to discusses circuitry that conditions the quadrature encoder signals before they get to the DAQ device to eliminate 'false' signals being sent to the DAQ device. The same system would apply to an M Series Device. I am not aware of any way to achieve this functionality in software. FYI, there is some good documentation for counters and counter applications for M Series. Take a look at the attached M Series help file. Hope this helps some.
    -Alan A.
    Attachments:
    M_Series_Help.zip ‏1145 KB

  • Speeding up quadrature encoder read out

    Hi,
    I`m using a quadrature encoder together with a 6259 DAQ Card and BNC2110 Terminal Block.
    I managed to have it working with the DAQ-Assistent at 80Mhz using the Counters and reading one value at a time. Before the DAQ-Assistent I used a DAQmx command to connect PFI10 and PFI9 as the BNC2110 Terminal only outputs PFI0-9. This works but it is really slow, the distance between each measurement point is around 6 us. The VI is in the attachement (AquadB_one_value.vi)
    So I thought I might use the n-values version with the DAQ-Assistent but this does not work and I dont see any reason why, it is complaining about that connection between PFI10 and PFI9 which it didnt do before in the one-value-version. The VI is also in the attachement (AquadB_n_values.vi)
    I also tried another method using a VI I was given some time ago and modified it but here the distance between each measurement point is also around 6us. This VI is also in the attachement (Counter - Read Encoder.vi)
    Or am I missunderstanding something? The minimum achievable time distance between measurement points should be 1/80.000.000 s where of course the value can only differ 1/0/-1 because it has only calculated one new change in the A and B Signals right? I thought with using the n-values it is storing all the calculated values in the memory and I am transferring them afterwards for doing all the "post-processing"?
    If I am wrong, how can I spped up the read-out of the calculated values any other way?
    Best regards
    Attachments:
    AquadB_n_values.vi ‏56 KB
    AquadB_one_value.vi ‏49 KB
    Counter - Read Encoder.vi ‏98 KB

    Hi Dani_munich,
    I just realized that you asked the same question in our Service request. In the service request, I was missing out more information which I found them here by chance . I will further assist you in the SRQ you have created. I also sent you an email.
    Regard
    Anoj
    Anoj Mubarak
    National Instruments

  • Encoder and E-series DAQ Board

    Hello!
    I am connecting a Quadrature Encoder to a PCI-MIO-16E-4 DAQ board.  The board is now called a PCI-6040E.  I am wondering how exactly to connect the Encoder to the DAQ board.  Direction is not necessarily that important, but it would be cool if the DAQ board could tell when the direction changed.  On the board are an out, gate and clock.  I don't know what to put where???  Please help me???
    Thank you,
    Tiffany Bierly

    CTR0 :
    A --> CTR0 SRC (pin 37)
    B --> P0.6 (pin 16)
    CTR1 :
    A --> CTR1 SRC (pin 42)
    B --> P0.7 (pin 48)
    See chapter 4 of this document for more details about using quadrature encoders with series E DAQ boards.

  • How to use external timebase for Two Edge Separation measurement with PCIe 6351

    Hi
    I am working with PCIe 6351 x series DAQ card.
    counter measurements.
    Here i need to measure the time/no edges between two edges. Falling to Raising of two signals.
    I got the measurement with internal time base.
    here i need to synchronize the measurements with external clock from the external setup.
    so i need to use that external clock,timebase for the counters.
    Any solution please..
    Regards,
    Hari

    First, the VI you mention is NOT for STC timer/counters. Therefore, it won't work.
    If you want to get the time interval between two edges, you want to use the Functions -> Data Acquisition -> Counter -> Count Events or Time VI. This will do the function you are looking for.
    Mark

  • RPM Measurement using Quadrature Encoder and PXI 6602 counter

    Hi,
    I am on a project at work where I need to verify the speed (in RPM) of an unloaded motor which can operate up to 1400 rpm.  After doing some research, i determined that a quadrature encoder could be used to make the measurement.  I am looking at this encoder  http://sine.ni.com/nips/cds/view/p/lang/en/nid/205321.
    I have a PXI 6602 counter/timer module in which I would like to interface to the quadrature encoder.  I would like to create a VI that allows me to calculate the speed using the encoder.  Can someone provide me with details of what needs to be in the VI or an example which can do this?  At the most basic level, i want to calculate the speed on demand.  After doing this, i would like to figure out how to quickly calculate the speed so that i can determine response time of the speed changing within sub-millisecond resolution (1 ms resolution max).
    Further, i created a VI that allows me to change the pulse width of a 100 Hz pulse train at run-time which tells the motor controller the desired speed.  I would like to be able to use this VI to change the speed of the motor and the first VI (that I am seeking help about) to calculate the response time (time between the initial speed and settling at the new setpoint).
    I am familiar with the NI example finder, but have not been able to find an example that I can use.
    Thanks,
    Gary

    Hey Gary,
    I think for you setup, you should try using the Meas Dig Frequency - Low Freq 1 ctr. You can find it by searching example finder with 'low freq'. This vi tells you the frequency of a digital signal by sampling between two pulses and inverting the time between pulses. If you hook up your encoder to a counter and have that counter specified in the vi, it will be able to give you on demand readings of frequency (you can do some multiplication to get the rpm value, freq*60/pulses per revolution of encoder). A simple way to take continuous readings is to put a while loop around the daqmx read and the data output of the read. You can also replace the numeric indicator to a waveform chart to graphically display the change of frequency or rpm readings over time.
    You should be able to integrate this as two separate tasks with the pulse train vi you created earlier.
    Hope this helps
    Luke W

  • Using quadrature encoders with PXI-6025

    Hi!,
    We are using an encoder for position data. The encoder gives A and B pulses which are phase shifted by 90 deg.
    Grating Pitch = 40 microns
    We make the connection to our PXI-6025 as such:
    Channel A pulse goes to PFI 8 (GPCTR_Source)
    Channel B pulse goes to DIO6 (GP_Up_Down)
    Ground goes to DGND
    We are able to increment/decrement the counter on our 6025 for every 40 micron movement
    However, we are unable to quad the input and increment/decrement for every 10 microns. How do we achieve this?
    We have an electronic circuit which converts the 40 micron A and B pulse from the encoder into 4 pulses spaced at 10 microns. But, using this single pulse mode does not allow for up/down counting.
    We are using LV-7.1
    , NI-DAQ 7.2 and Win2000 prof.
    Looking forward to some quick help.
    Thanks,
    Gurdas
    Gurdas Singh
    PhD. Candidate | Civil Engineering | NCSU.edu

    There's one tedious way that might work if you only need to post-process the data. However there are several possible problems.
    The idea is to perform buffered semi-period measurements with both the counters on the 6025. Once you've collected all the needed semi-period data, perform a cumulative sum of each array so you end up with timestamps for all the transitions. Then you'll need to go through them to distinguish (+) from (-) direction quadrature transitions and generate a cumulative position array.
    I don't think there's another way -- only semiperiod measurements will react to both edges of an incoming pulse train. However, it *is* possible in principle to get your 4x factor in resolution. Now for the problem list:
    1. Your 6025E only has 1 DMA channel. One of the counters will have to be configured to use interrupts, which in turn will limit the maximum encoder rate you can track. I wouldn't count on tracking better than single digits of kHz, and you may not even be able to achieve that much.
    2. The last time I did semiperiods on an E-series board, there was no way to specify which edge would mark the first recognized transition. If the input was low when you started, the first transition recorded would be a rising edge; if high, then a falling edge.
    Knowledge of the initial state of the inputs is critical for your software quadrature decoding. I think the solution I used was to parallel wire the A&B channels to a couple DIO pins which I inspected before any encoder motion started. If your encoder jitters or vibrates about its nominal position however, you're probably hosed.
    Are you sure you can't use the LS7084 to replace your other external circuit? The alternatives are either going to be trouble-prone gimmicks like I described above or the purchase of new DAQ equipment.
    If you have budget for new DAQ equipment from NI, I'd suggest you look into one of the following:
    1. Low-cost M series multi-function board
    These have 2 32-bit counters onboard that are capable of quadrature decode. Each counter gets its own DMA channel for buffered acquisition. Plus you get a bunch of analog in, timed digital i/o, and can get analog outs. The boards are $475 with 2 analog outputs, $375 with none.
    2. dedicated counter/timer board
    The 6601 is cheaper at $295, but is limited to 1 DMA channel and has a slower onboard timing clock. The 6602 costs about double that but gives you somewhat more than double capability.
    -Kevin P.

  • Measuring distance using quadrature encoder

    I am currently doing a project that requires the positioning and characterization of TV signals. As such, the position of the TV receiver is one  important variable that i have to measure. I am required to automate the measurements and data logging using a PC/notebook. I have purchased a 2-channel HEDS-9000 quadrature encoder with 2000 CPR & the HEDS6120 codewheel - both from Avago Tech, to be interfaced with the notebook/PC. My idea is to get a TTL-to-RS232-to-USB converter to interface with the PC, so that i can feed the output from the encoder to the PC. However, i dun have much idea on how I can use LabView to interface the encoder and the PC. Can anyone offer some valuable advice?
    Btw, the encoder module consists of 5 pins - Vcc, GND, CH.A, CH.B, with one pin not used.
    Thanks !!

    Hi,
    I think one of the best and reliable options that should meet your needs is a bus-powered USB-M-Series device like the USB-6210.
    The USB-6210 is a multifunction data acquisition device with 16 analog inputs, 4 digital inputs, 4 digital outputs and 2 counters. Each of the counters can interface directly to the quadrature encoder signals of your HEDS-9000.
    It's very easy to use this device with the NI-DAQmx API for position measurements in LabVIEW. In fact there are some shipping examples that you can use for getting started.
    I hope this helps,
    Jochen Klier
    National Instruments Germany
    Message Edited by Jochen on 02-09-2007 09:18 AM

Maybe you are looking for

  • No Startup Chime on the Boss's MacBook

    My boss is currently in Mexico and his MacBook has started having problems. He can turn it on, the power light comes on and the HD starts spinning, but it never gets to the startup chime. It simply continues to run with a black screen until he holds

  • HT2375 how do I uninstall logic studio from my macbook  pro?

    i need to uninstall logic studio from my computer to make more space on my drive.  I want all the programs associated with logic studio gone.

  • How to convert number to string in java

    hi how can i convert number to string in java something like public void Discription(Number ownerName){ String.valueOf(ownerName);Edited by: adf009 on 2013/04/08 7:14 PM

  • IWeb upgrade??

    The new iLife is great but....something is missing. Where is the missing iWeb upgrade? Is Apple working on a new web authoring program to replace iWeb...something that will knock the socks off anything out there? Well, here is hoping! In the meantime

  • First generation email account set-up

    I've tried numerous times to set up my email account on the iphone and have met with negative results each time. Have been into the ATT store twice and an apple store and an apple rep. over the phone and can't seem to get it done. I have my pc email