Question about input impedance

Hi everyone,
I was trying to measure a voltage source with 10kohm internal impedance, and I connect the source directly with NI-USB 6009. When the voltage source is 5.043V, the data recorded by labview is around 4.8V. I checked the manual of USB-6009 and found that the input circuit (see the attachment). So I guess when the device was taking data, it was actually taking the data on the crossing node and then converted it back with impedance figures shown in the graph. That's why I got data lower than it should have been.
I was wondering is there any way to deal with it, other than calculating back and converting it with correct impedance?
Regards,
Jude
Solved!
Go to Solution.
Attachments:
屏幕快照 2013-07-18 下午12.19.32.png ‏22 KB

Hi Jude,
you could use an OpAmp to amplify your signal (1:1) an so lower the impedance seen by the USB6009. You could also use some other DAQ hardware with higher input impedance.
In the end the conclusion is: you have to choose your DAQ hardware according to specifications of signal source. You have chosen the wrong hardware...
Best regards,
GerdW
CLAD, using 2009SP1 + LV2011SP1 + LV2014SP1 on WinXP+Win7+cRIO
Kudos are welcome

Similar Messages

  • Question about inputting data to a pivot table

    Hi,
    I have 2 questions about using the ADF pivot table component (I would like it for data input).
    1. Is it possible to paste into multiple cells (i.e. using cut in Excel for example, and then pasting the cells into the pivot table) ?
    2. What is the recommended approach for the case where there is no data values (no rows on the database table)? For example, if I have regions, products, measures and time periods and then want to be able to select some regions and some products to enter new sales figures - and then create the rows on the database with save button, is there a recommended way to do this?
    (Jdeveloper version: 11.1.2.0.0)

    Anybody able to help with this?

  • A question about input values inside PL/SQL block

    Dear all,
    I would appreciate if you could kindly help me with this question.
    Consider the following code.
    DECLARE
      myvar1 NUMBER;
      myvar2 NUMBER;
      myvar3 NUMBER;
    BEGIN
      myvar1 := &1;
      myvar2 := &2;
      myvar3 := &3;
      DBMS_OUTPUT.put_line('myvar1 = ' || myvar1);
      DBMS_OUTPUT.put_line('myvar2 = ' || myvar2);
      DBMS_OUTPUT.put_line('myvar3 = ' || myvar3);
    END;
    /This program reads three values as input and prints them. However, I noticed that if instead of writing
    myvar1 := &1;
    myvar2 := &2;
    myvar3 := &3;I write
    myvar1 := '&1';
    myvar2 := '&2';
    myvar3 := '&3';The program will have very same result. I would like to know whether there is a semantic difference between both syntax,
    that is, is there any difference between for example &myvar1 and 'myvar1'?
    Thanks in advance,
    Dariyoosh

    Try this
    CREATE TABLE test_sem  (x VARCHAR2(10), y NUMBER)
    INSERT INTO test_sem VALUES ('A',1);
    INSERT INTO test_sem VALUES ('B',1);
    INSERT INTO test_sem VALUES ('C',1);
    INSERT INTO test_sem VALUES ('D',1);
    SELECT * FROM test_sem WHERE x='&1' --OK
    SELECT * FROM test_sem WHERE x=&1 -- error not a valid number
    SELECT * FROM test_sem WHERE y=&1 -- ok
    SELECT * FROM test_sem WHERE y='&1' -- ok since numbers can be converted to strings'&1' is for characters &1 for numbers;
    You can verify form above test case
    Regards,
    Bhushan

  • Question About Inputs

    Right now I have a TDM HD2 System.
    I am new to Logic 8, though used to have Logic 7 last year for a few months. So far, very impressed and everything is working OK tonight (I just installed L8 a couple hours ago). So I'm just SLOWLY playing around, seeing if I can grasp everything and remember how it works. I promise to read the manual. BUT....
    I have a 96 i/O Digi interface, and it has a mic going in INPUT 1. I can add a track in Logic and hear this mic fine. I also have an ADAT lightpipe coming into the Digi interface from a second Mac. It carries 8 channels of samples I run off the other Mac. I cannot figure out how to get Logic to see these ADAT inputs, because the choice in the drop down menu is Audio 1-8 only. So it sees my analog inputs, but not the adats. Any ideas?
    Thanks
    Tom

    Logic will make available any audio inputs that OSX tells it exist.
    Run the Audio/MIDI setup utility - are you other devices displayed there? If not, OSX doesn't know about them. Do they have core audio drivers, or are they proprietry Digi things?

  • Just ordered my dv7t series notebook and question about inputs

    I have an older Promedia Ultra 5.1 sound system that was once connected to my Dell desktop that now crashed.  I LOVE these speakers and would really love to use them when I want to play music from my laptop. Are there inputs on the laptop for me to plug these into..there are 3 mini plugs.
    Thanks!! 

    Logic will make available any audio inputs that OSX tells it exist.
    Run the Audio/MIDI setup utility - are you other devices displayed there? If not, OSX doesn't know about them. Do they have core audio drivers, or are they proprietry Digi things?

  • Questions about input/output streams

    In the following tutorial:
    http://chortle.ccsu.ctstateu.edu/CS151/Notes/chap85/ch85_10.html
    It mentions that some methods, such as write(), writeByte(), writeBytes(), and writeChar(), return the low eight bits of the argument to the output stream. I am a little unsure of what exactly that means, might somebody be able to clarify for me?
    In addition, I've been encountering the flush() method in some of the byte- and character-streaming objects that deal with buffers. What exactly is the flush() method's purpose, and when might it be used? Thank you.

    flush pushes the data out of the buffer. the write methods write to the buffer, when the buffer is full, it flushes itself (usually), or it could block the write methods (in theory). flush just lets you make sure that it's flushed.
    I'm not sure there's any reason to worry about high and low bytes in Java most of the time. I suppose, like anything, there's times you need to, but I can't think of any offhand.

  • Simple question about Input Methods

    Hi everyone. I have a JTextArea in a frame. I want this TextArea to accept Chinese language directly from keyboard. For this I need to select an Input Method.
    One way to select an Input Method is to click on the control icon on the top left corner of the frame window and then select "Input Methods > Chinese".
    But I dont want selecting input method this way. I want to select Input Method for my TextArea within the code in frame's constructor.
    I do hope that you are getting my point.
    I tried like this:
    TextArea.selectInputMethod( new Locale("SIMPLIFIED_CHINESE"));
    But it gives me error that "cannot find method selectInputMethod()".
    I shall be very very very thankfull to you.
    Thanx
    ..::DW

    Yeh, it would be simpler to run a test, but i'm not at a workstation with a jdk or IDE at the moment!
    Thanks for the response though!

  • HT201303 hi just got my new apple ipod touch i need to update my security information other wise it wont let me download apps it says to enter three questions about myself and i get to the third question and it wont let me enter the third question

    hi just got my new apple ipod touch and to download apps it wants to add questions about myself for more sercurity information. i get up to question 3 and it wont let me select a question but it will let me write an answer so i just pressed done and then it says i cant carry on because ive mised out information when it wont let me do a question!

    Welcome to the Apple community.
    You might try to see if you can change your security questions. Start here, change your country if necessary and go to manage your account > Password and Security.
    I'm able to do this, others say they need to input answers to their current security questions in order to make changes, I'm inclined to think its worth a try, you don't have anything to lose.
    If that doesn't help you might try contacting Apple through Express Lane (select your country, navigate to iCloud help and enter the serial number of one of your devices)

  • Questions about using a PDF form online

    I have a client who wants to create an online version of a PDF form that they are currently using. I am currently trying to explain to them that this would be best done as an HTML web form, but I may not win this argument. I have only used PDFs for printed forms (either hand-written or using form fields) so I am not familiar with any problems that converting the form for use online would entail.
    When the 'Submit' button is pressed on the form, is there a way to redirect to another web page after the data is submitted? (i.e. does the PDF have access to it's outer 'environment'?)
    Are there any security issues submitting data using the PDF form as opposed to using a standard web form? (There may be sensitive data being submitted)
    I'm not sure how they plan to handle the data that is submitted, but there are several options in the submitForm parameters - I am assuming that using the HTML option would submit the data in the same format as a web form would. Am I correct here?
    Can the PDF be prevented from being downloaded or printed? This form should only be used to submit data to their server, not as a printed form.
    Are there any other 'gotchas' that I need to look out for? Does anyone have a recommendation for a site which contains any tutorials or guidelines for using PDF forms online?

    Thanks for the information.
    Yes, I agree that there is less reason for it to be a PDF form (Actually, no real reason other than the original form already exists in PDF), but I am unfortunately in the position that my input in this project is not necessarily being considered (my company is following direct -and inconsistent- directions from the client, and I have no contact with the client to ask questions about what their actual needs are). I have been told to give the client the 'Tomato' that they are asking for, even though they are describing an 'Apple'.
    The reason this form is not meant to be printed is that we have replaced the 'Signature' fields from the original form with checkboxes that the user must check to confirm they have 'signed' the document. If they are to print/fax/whatever the document, they should use the original form, not this one. And I am still trying to explain to them that this would be better served with an HTML web form, but I fear I am losing that battle.
    I have brought up the fact that it is not 100% guaranteed that Acrobat will be available in the browser, although I can only guess that it is less than likely that anyone will not have some sort of PDF viewer available to their browser.
    I will also mention that issues may arise if the file is not submitted from within the browser.

  • Few questions about Earthing?

    Hi all,
    I have some basic questions about earthing. Please anyone explain them and provide any reference material also.
    Q1. In Industries there are normally two types of earth, one is "Instrument Earth" and other is "Protective Earth". what is the difference between these two?
    Q2 what is the difference between AC and DC earthing?
    Any help will be appreciated.

    To Q1:
    Both are connected at one point , however the PE can (and will) carry more noise due to currents (up to 30mA or even 300mA depending one the installed RCD, in some cases even higher ) from line filters in switched power converters , C&L coupling to the line power etc..
    While the PE is build (and tested! ) for low resistance  the impedance (here inductivity) can be quite high, so RF content is not well grounded.
    So a instrument earth as an separated path is build up, but not with the intend to carry lot of current, just to establish a clean ground potential.
    To Q2:  A capacitor to ground will be low impedance for high frequency (Z=1/(j*2*pi*f*C)) but not for DC . On the other hand an inductivity is a good conductor for DC , but not for AC (Z=j*2*pi*f*L).
    Depending on the task you have, you can decide what part you tide to ground.
    Greetings from Germany
    Henrik
    LV since v3.1
    “ground” is a convenient fantasy
    '˙˙˙˙uıɐƃɐ lɐıp puɐ °06 ǝuoɥd ɹnoʎ uɹnʇ ǝsɐǝld 'ʎɹɐuıƃɐɯı sı pǝlɐıp ǝʌɐɥ noʎ ɹǝqɯnu ǝɥʇ'

  • Few questions about apex + epg and cookie blocked by IE6

    Hi,
    I would like to ask a few questions about apex and epg.
    I have already installed and configured apex 3.2 on oracle 10g (on my localhost - computer name 'chen_rong', ip address -192.168.88.175 ), and enable anonymous access xdb http server.
    now,
    1. I can access 'http://chen_rong' , 'http://localhost' , 'http://192.168.88.175' without input username / password for realm 'XDB' in IE6;
    2. I can access 'http://localhost/apex/apex_admin' , 'http://192.168.88.175/apex/apex_admin' , and I can be redirected into apex administation page after input admin/<my apex admin password> for realm 'APEX' in IE6;
    3. I can access 'http://chen_rong/apex/apex_admin' in IE6, but after input admin/password , I can not be redirected into administation page, because the cookie was blocked by IE6.
    then, the first question is :
    Q1: What is the difference among 'http://chen_rong' , 'http://localhost' , 'http://192.168.88.175' ? I have already include site 'chen_rong' into my trusted stes! why the cookie was blocked by IE6. I have already tried firefox and google browser, both of them were ok for 'chen_rong', no cookie blocked from site 'chen_rong'!
    and,
    1. I have tried to use the script in attachment to test http authentication and also want to catch the cookie by utl_http .
    2. please review the script for me.
    3. I did:
    SQL> exec show_url('http://localhost/apex/apex_admin/','ADMIN','Passw0rd');
    HTTP response status code: 401
    HTTP response reason phrase: Unauthorized
    Please supplied the required Basic authentication username/password for realm XDB for the Web page.
    Web page http://localhost/apex/apex_admin/ is protected.
    MS-Author-Via: DAV
    DAV: 1,2,<http://www.oracle.com/xdb/webdav/props>
    Server: Oracle XML DB/Oracle Database
    WWW-Authenticate: Basic realm="XDB"
    Date: Tue, 04 Aug 2009 02:25:15 GMT
    Content-Type: text/html; charset=GBK
    Content-Length: 147
    ======================================
    PL/SQL procedure successfully completed
    4. I also did :
    SQL> exec show_url('http://localhost/apex/apex_admin/','ANONYMOUS','ANONYMOUS');
    HTTP response status code: 500
    HTTP response reason phrase: Internal Server Error
    Check if the Web site is up.
    PL/SQL procedure successfully completed
    SQL> exec show_url('http://localhost/apex/apex_admin/','SYSTEM','apexsite');
    HTTP response status code: 401
    HTTP response reason phrase: Unauthorized
    Please supplied the required Basic authentication username/password for realm APEX for the Web page.
    Web page http://localhost/apex/apex_admin/ is protected.
    Content-Type: text/html
    Content-Length: 147
    WWW-Authenticate: Basic realm="APEX"
    ======================================
    PL/SQL procedure successfully completed
    my second questions is :
    Q2: After I entered into realm 'XDB', I still need went into realm'APEX'. how could I change the script show_url to accomplish these two tasks and successfully get the cookie from site.
    the show_url script is as following:
    CREATE OR REPLACE PROCEDURE show_url
    (url IN VARCHAR2,
    username IN VARCHAR2 DEFAULT NULL,
    password IN VARCHAR2 DEFAULT NULL)
    AS
    req UTL_HTTP.REQ;
    resp UTL_HTTP.RESP;
    name VARCHAR2(256);
    value VARCHAR2(1024);
    data VARCHAR2(255);
    my_scheme VARCHAR2(256);
    my_realm VARCHAR2(256);
    my_proxy BOOLEAN;
    cookies UTL_HTTP.COOKIE_TABLE;
    secure VARCHAR2(1);
    BEGIN
    -- When going through a firewall, pass requests through this host.
    -- Specify sites inside the firewall that don't need the proxy host.
    -- UTL_HTTP.SET_PROXY('proxy.example.com', 'corp.example.com');
    -- Ask UTL_HTTP not to raise an exception for 4xx and 5xx status codes,
    -- rather than just returning the text of the error page.
    UTL_HTTP.SET_RESPONSE_ERROR_CHECK(FALSE);
    -- Begin retrieving this Web page.
    req := UTL_HTTP.BEGIN_REQUEST(url);
    -- Identify yourself.
    -- Some sites serve special pages for particular browsers.
    UTL_HTTP.SET_HEADER(req, 'User-Agent', 'Mozilla/4.0');
    -- Specify user ID and password for pages that require them.
    IF (username IS NOT NULL) THEN
    UTL_HTTP.SET_AUTHENTICATION(req, username, password, 'Basic', false);
    END IF;
    -- Start receiving the HTML text.
    resp := UTL_HTTP.GET_RESPONSE(req);
    -- Show status codes and reason phrase of response.
    DBMS_OUTPUT.PUT_LINE('HTTP response status code: ' || resp.status_code);
    DBMS_OUTPUT.PUT_LINE
    ('HTTP response reason phrase: ' || resp.reason_phrase);
    -- Look for client-side error and report it.
    IF (resp.status_code >= 400) AND (resp.status_code <= 499) THEN
    -- Detect whether page is password protected
    -- and you didn't supply the right authorization.
    IF (resp.status_code = UTL_HTTP.HTTP_UNAUTHORIZED) THEN
    UTL_HTTP.GET_AUTHENTICATION(resp, my_scheme, my_realm, my_proxy);
    IF (my_proxy) THEN
    DBMS_OUTPUT.PUT_LINE('Web proxy server is protected.');
    DBMS_OUTPUT.PUT('Please supply the required ' || my_scheme ||
    ' authentication username/password for realm ' || my_realm ||
    ' for the proxy server.');
    ELSE
    DBMS_OUTPUT.PUT_LINE('Please supplied the required ' || my_scheme ||
    ' authentication username/password for realm ' || my_realm ||
    ' for the Web page.');
    DBMS_OUTPUT.PUT_LINE('Web page ' || url || ' is protected.');
    END IF;
    ELSE
    DBMS_OUTPUT.PUT_LINE('Check the URL.');
    END IF;
    -- UTL_HTTP.END_RESPONSE(resp);
    -- RETURN;
    -- Look for server-side error and report it.
    ELSIF (resp.status_code >= 500) AND (resp.status_code <= 599) THEN
    DBMS_OUTPUT.PUT_LINE('Check if the Web site is up.');
    UTL_HTTP.END_RESPONSE(resp);
    RETURN;
    END IF;
    -- HTTP header lines contain information about cookies, character sets,
    -- and other data that client and server can use to customize each
    -- session.
    FOR i IN 1..UTL_HTTP.GET_HEADER_COUNT(resp) LOOP
    UTL_HTTP.GET_HEADER(resp, i, name, value);
    DBMS_OUTPUT.PUT_LINE(name || ': ' || value);
    END LOOP;
    -- Read lines until none are left and an exception is raised.
    --LOOP
    -- UTL_HTTP.READ_LINE(resp, value);
    -- DBMS_OUTPUT.PUT_LINE(value);
    --END LOOP;
    UTL_HTTP.GET_COOKIES(cookies);
    dbms_output.put_line('======================================');
    FOR i in 1..cookies.count LOOP
    IF (cookies(i).secure) THEN
    secure := 'Y';
    ELSE
    secure := 'N';
    END IF;
    -- INSERT INTO my_cookies
    -- VALUES (my_session_id, cookies(i).name, cookies(i).value,
    -- cookies(i).domain,
    -- cookies(i).expire, cookies(i).path, secure, cookies(i).version);
    dbms_output.put_line('site:'||url);
    dbms_output.put_line('cookies:');
    dbms_output.put_line('name:'||cookies(i).name);
    dbms_output.put_line('value:'||cookies(i).value);
    dbms_output.put_line('domain:'||cookies(i).domain);
    dbms_output.put_line('expire:'||cookies(i).expire);
    dbms_output.put_line('path:'||cookies(i).path);
    dbms_output.put_line('secure:'||secure);
    dbms_output.put_line('version:'||cookies(i).version);
    END LOOP;
    UTL_HTTP.END_RESPONSE(resp);
    EXCEPTION
    WHEN UTL_HTTP.END_OF_BODY THEN
    UTL_HTTP.END_RESPONSE(resp);
    END;
    /

    I use oracle database enterprise edtion 10.2.0.3. I have already figured out the epg on 10.2.0.3 to support apex 3.2.
    And as I described above, the apex site works fine for ip address , and localhost. but the cookie will be blocked by IE6, if I want to access the site by 'http://computername:port/apex/apex_admin'. This problem does not occured in firefox and google browser. Could someone give me answer?

  • Question about the programming of a legend

    Hello everybody,
    I have a question about the programming of a waveform's legend. I
    already asked here in this forum about the legend programming (03)
    months ago.
    I went satisfied but I ve just noticed that this code
    (See Code old_legend_test.llb with main.vi as main function) operates a
    little different from my expectances.
    Therefore I have a new question and I want to know if it
    is possible by labview programming to plot and show, on a waveform
    chart, a signal with activ plot superior to zero (0) without to be
    obliged to plot and show a signal with activ plot equal to zero (0) or
    inferior to the desired activ plot.
    I give you an example
    of what I m meaning. I have by example 4 signals (Signal 0, 1, 2 and 3)
    and each signal corresponds respectively to a channel (Chan1, Chan2,
    Chan3, Chan4). I want to control the legend (activ plot, plot name and
    plot color) programmatically. Is it possible with labview to plot signal
    1 or 2 or 3 or (1, 3) or (2,3) or (1,2,3) or other possible combination
    without to active the signal with the corresponding activ plot zero
    (0)?
    Let see the labview attached data
    (new_legend_test.llb with main.vi as main function). When I try to
    control the input selected values again I get them back but I don't
    understand why they have no effect on the legend of my waveform chart.
    Could somebody explain me what I m doing wrong or show me how to get a
    correct legend with desired plots? Thank by advance for your assistance.
    N.B.
    The
    both attached data are saved with labview 2009.
    Sincerly,PrinceJack
    Attachments:
    old_legend_test.llb ‏65 KB
    new_legend_test.llb ‏65 KB

    Hi
    princejack,
    Thanks for
    posting on National Instruments forum.
    The behavior
    you have is completely normal. You can control the number of row displayed in
    the legend and this rows are linked to the data you send to your graph. Thus,
    if you have 3 arrays of data, let say chan1, chan2 and chan3, you can choose
    which data you want to display in your graph using the property node (Active
    plot and visible). But for the legend as you send 3 plots there is an array of
    the plot name [chan1, chan2, chan3] and you can display 0, 1, 2 or 3 rows of
    this array but you cannot control the order in this array! So, to be able to
    change this array you have to only send data you need to you graph. I'm not
    sure my explanations are clear so I have implemented a simple example doing
    that.
    Benjamin R.
    R&D Software Development Manager
    http://www.fluigent.com/
    Attachments:
    GraphLegend.vi ‏85 KB

  • One question about Pricing and Conditions puzzle me for a long time!

    One question about Pricing and Conditions puzzle me for a long time.I take one example to explain my question:
    1-First,my sale order use pricing procedure RVAA01.
    2-Next,the pricing procedure RVAA01 have some condition type,such as EK01(Actual Costs),PR00(Price)....,and so on.
    3-Next,the condition type PR00 define the Access Sequences PR00 as it's Access Sequences.
    4-Next,the Access Sequences PR00 have some Condition tables,such as:
         table 118 : "Empties" Prices (Material-Dependent)
         table 5 : Customer/Material
         table 6 : Price List Type/Currency/Material
         table 4 : Material
    5-Next,I need to maintain Condition tables's Records.Such as the table 5(Customer/Material).I guess the sap would supply one screen for me to input the data of table 5.At this screen,the sap would ask me to select one table,such as table 5.When I select the table 5,the sap would go to the screen to let me input the data of table 5.But when I use the T-CODE VK31 or VK32 to maintain Condition tables's Record,I found it's total different from my guess:
    A-First,I can not found one place for me to open the table,such as table 5,to let me input the data?
    B-Second,For example,when I select the VK31->Discounts/Surcharges->By Customer/Material,the sap show the grid view at the right side.At the each line of the grid view,you need to select the Condition Type at the first field.And this make me confused very much.Why the sap need me to select one Condition Type but not the Condition table?To the normal logic,it ought not to select Condition table but not the Condition Type!
    Dear all,I'm a new one in sd.May be this is a very stupid question.But it did puzzle me for a long time.If any one can  explain this question in detail and let me understand the concept,I will appreciate him/her very much.Thank you.

    Hi,
    You said that you are using the T.codes VK31 or VK32.
    These transaction codes are used to enter condition records for standard condition types. As you can see a grid left side having all the standard condition types like price, discounts, taxes, frieghts.
    Pl check using T.code VK11 OR VK12 (change mode)
    Here you can enter the required condition type, in the intial screen. (like PR00, MWST, K004, K005 .....etc)
    After giving the condition type, press enter or click on Combinations icon on top of the screen. Then you can see all the condition tables which you maintained for that condition type. Like as you said table 118, table 5, table 6 and table 4.
    You can select any table and press enter, then you can go into the screen in which you have all the field cataglogues you maintained for that table. For example you selected combination of Customer/Material (table 5) then after you press enter then you can see customer field on top, and material fields.
    You can give all the required values and save the conditon record.
    Hope this is clear.
    REWARD IF HELPFUL.
    Regards,
    praveen

  • Basic questions about Infocube

    Hi, everyone.
    I got very basic questions about infocube data handling.
    With infopackage, I extracted all the data about employees from R/3.
    But there were some mistakes during inputting employee data, like positions,
    so I just extracted those employees data once more.
    Now I have two requests in infocube, where the first one has some wrong data.
    Is there any solutions about this?
    I might got it all wrong, so as beginner, any suggestions and explanations will
    be grateful.

    Hi,
    You can manually delete the earlier request by going in the Manage option of the cube. select the request and click on delete icon at the bottom.
    Other option is to make setting in the Infopackage to delete similar or overlapping request.
    Data target tab --> 6th column Automatic loading / deletion of similar request. --> click on the blank icon --> you will get a pop-up --> select the radio button - "delete existing request" --> Select Conditions --> Infosource are same, datasource are same and source system are same, --> selections are "Same or  More Comprehensive "
    Assign points if useful
    Regards
    Venkata Devaraj !!!

  • Question about metadata filtering and document sets

    Hello,
    I have a question about the metadata filtering when using document sets.
    When i use the metadata filter for example for "Installatie: P00001" it shows.
    But i wan't to show only the document set and not all the documents. Is this possible OOTB?

    Hi striker,
    You can add the "Content Type" in Hierarchy Fields for your list, then click the "Document Set" to filter the document set type item, then you can input the "P00001" in Installatle key filter, click apply, then it should show only document set
    items with field value P00001.
    http://office.microsoft.com/en-001/sharepoint-help/set-up-metadata-navigation-for-a-list-or-library-HA102832523.aspx
    Thanks
    Daniel Yang
    TechNet Community Support

Maybe you are looking for

  • Xml file read in a single line

    HI All, I have configured a scenario FILE-FILE to generate a XML file as output(input also xml file). It has created xml file successfully, and this file is transferred from ECC5.0 to 4.7. In 4.7 this xml file is read by a particular program in which

  • P105-S9337 Problems - BIOS?

    Aloha, I have a friend who has a P105-S9337 that came preinstalled with Vista Home. He came to me after he installed some softwares noticing that it didn't work as fast as it should. I've taken a quick look and discovered that it had automatic update

  • Customer Expected Price - Issue

    Hi, I have added the EDI1 & EDI2 CTypes in the Pricing procedure with requirements 9 & 8 respectively. While i create the sales order with PR00 = 1000 USD and add manually EDI1 = 750 USD the system saves the order normally & delivery could be process

  • Importing an AAF into Premiere Pro

    Hello. I am trying to learn the AAF workflow so that I can share my feature film edit with a sound mixer. I begin with an edit in Premier Pro CC and export the AAF file. All the media seems to export fine. I then re-import the AAF file into Premiere

  • Safari won't launch after upgrade to Leopard

    I upgraded from Tiger to Leopard and now when I launch my Safari browser I get an error saying "You cannot use the application "Safari" with this version of Mac OS X. Also when I try to reinstall Safari from Apple.com I get an error saying "...kfjcl5