Read data from Vector object serialized in a file issue!!

Hi all,
I have two classes :CBase and CHelper class in a package and serializing some information in a file and then reading it. I am facing some problem while reading the data
which was stored using vector of objects. Below is the detailed problem:::::
////////////CHELPER
public class CHelper implements Externalizable, Cloneable {
public string szname;
//..other functions writeexternal read external
////////////CBASE
public class CBase
implements Externalizable, Cloneable {
protected boolean bRead;
protected boolean bWrite;
protected Vector vData;
public void addInstance(CHelper obj) {
vData.addElement(obj);
//..other functions writeexternal read external
I am Serializing all the CBase information in a file and trying to read the contents from this serialized file::::
CBase base = new CBase();
CHelper obj = new CHelper();
obj.setName("HELPER");
base.addInstance(obj); // ADDING THE OBJECT DATA INTO THE VECTOR
base.bRead = true;
base.bWrite = true;
// Writing to the file
FileOutputStream fs = new FileOutputStream("d:\\temp\\Base.txt");
ObjectOutputStream os = new ObjectOutputStream(fs);
os.writeObject(base);
os.close();
//reading from the file
FileInputStream fi = new FileInputStream("d:\\temp\\Base.txt");
ObjectInputStream oi = new ObjectInputStream(fi);
CBase read = (CBase) oi.readObject();
PRINTING THE OUTPUT
System.out.println("Vector = " + read.vData.firstElement().toString());
System.out.println("Write = " + read.bRead);
System.out.println("Read = " + read.bWrite);
The output is something like:
Vector = com.sp.CHelper@14b7453 // WHAT IS THIS ?? GARBAGE ?? NOT ABLE TO ANALYSE :(
Write = true;
Read = true;************
MY PROBLEM:
i.e How to get the information stored in the Vector ? I am getting something "com.sp.CHelper@14b7453 " whereas the expected output should be Vector = HELPER. I am
writing and reading the vector as follows:
// CHELPER
public void writeExternal(ObjectOutput out) throws IOException {
out.writeUTF(szName.toString());
public void readExternal(ObjectInput in) throws IOException,
ClassNotFoundException {
setName(in.readUTF());
Externalize in CBase Classs
out.writeInt(getInstanceCount()); // getting number of objects in the vector
for (int index = 0; index < getInstanceCount(); index++) {
out.writeObject((CHelper)vData.get(index));
out.writeBoolean(bWrite);
out.writeBoolean(bRead);
And reading like this::
int iNumberofInstances; // number of instances
iNumberofInstances = in.readInt();
vData.clear();
// Get the CHelper object and add it into the CFeatureBase vector
for (int i = 0; i < iNumberofInstances; i++) {
CHelper objbase = (CHelper)in.readObject();
vData.add(objbase);
this.bWrite = in.readBoolean();
this.bRead = in.readBoolean();
I suppose that i am correctly WRITING AND READING the data. B/w what can be the problem. All suggestions are welcome/
Thanks,
Rohit

Vector = com.sp.CHelper@14b7453 // WHAT IS THIS ??
GARBAGE ?? NOT ABLE TO ANALYSE :(
Write = true;
Read = true;************
MY PROBLEM:
i.e How to get the information stored in the Vector
? I am getting something "com.sp.CHelper@14b7453 "
whereas the expected output should be Vector =
HELPER.This is perfectly normal behaviour if your CHelper class doesn't override the toString() method. The default toString() method in Object just prints the name of the class and a hex representation of the object's hash code.
Add a toString() method to CHelper that returns szname and you should see what you are expecting.

Similar Messages

  • External table: How to load data from a fixed format UTF8 external file

    Hi Experts,
    I am trying to read data from a fixed format UTF8 external file in to a external table. The file has non-ascii characters, and the presence of the non-ascii characters causes the data to be positioned incorrectly in the external table.
    The following is the content's of the file:
    20100423094529000000I1 ABÄCDE 1 000004
    20100423094529000000I2 OMS Crew 2 2 000004
    20100423094529000000I3 OMS Crew 3 3 000004
    20100423094529000000I4 OMS Crew 4 4 000004
    20100423094529000000I5 OMS Crew 5 5 000004
    20100423094529000000I6 OMS Crew 6 6 000004
    20100423094529000000I7 Mobile Crew 7 7 000004
    20100423094529000000I8 Mobile Crew 8 8 000004
    The structure of the data is as follows:
    Name Type Start End Length
    UPDATE_DTTM CHAR 1 20 20
    CHANGE_TYPE_CD CHAR 21 21 1
    CREW_CD CHAR 22 37 16
    CREW_DESCR CHAR 38 97 60
    CREW_ID CHAR 98 113 16
    UDF1_CD CHAR 114 143 30
    UDF1_DESCR CHAR 144 203 60
    UDF2_CD CHAR 204 233 30
    DATA_SOURCE_IND CHAR 294 299 6
    UDF2_DESCR CHAR 234 293 60
    I create the external table as follows:
    CREATE TABLE "D_CREW_EXT"
    "UPDATE_DTTM" CHAR(20 BYTE),
    "CHANGE_TYPE_CD" CHAR(1 BYTE),
    "CREW_CD" CHAR(16 BYTE),
    "CREW_DESCR" CHAR(60 BYTE),
    "CREW_ID" CHAR(16 BYTE),
    "UDF1_CD" CHAR(30 BYTE),
    "UDF1_DESCR" CHAR(60 BYTE),
    "UDF2_CD" CHAR(30 BYTE),
    "DATA_SOURCE_IND" CHAR(6 BYTE),
    "UDF2_DESCR" CHAR(60 BYTE)
    ORGANIZATION EXTERNAL
    TYPE ORACLE_LOADER DEFAULT DIRECTORY "TMP"
    ACCESS PARAMETERS ( RECORDS DELIMITED BY NEWLINE
    CHARACTERSET UTF8
    STRING SIZES ARE IN BYTES
    NOBADFILE NODISCARDFILE NOLOGFILE FIELDS NOTRIM
    ( "UPDATE_DTTM" POSITION (1:20) CHAR(20),
    "CHANGE_TYPE_CD" POSITION (21:21) CHAR(1),
    "CREW_CD" POSITION (22:37) CHAR(16),
    "CREW_DESCR" POSITION (38:97) CHAR(60),
    "CREW_ID" POSITION (98:113) CHAR(16),
    "UDF1_CD" POSITION (114:143) CHAR(30),
    "UDF1_DESCR" POSITION (144:203) CHAR(60),
    "UDF2_CD" POSITION (204:233) CHAR(30),
    "DATA_SOURCE_IND" POSITION (294:299) CHAR(6),
    "UDF2_DESCR" POSITION (234:293) CHAR(60) )
    ) LOCATION ( 'D_CREW_EXT.DAT' )
    REJECT LIMIT UNLIMITED;
    Check the result in database:
    select * from D_CREW_EXT;
    I found the first row is incorrect. For each non-ascii character,the fields to the right of the non-ascii character are off by 1 character,meaning that the data is moved 1 character to the right.
    Then I tried to use the option STRING SIZES ARE IN CHARACTERS instead of STRING SIZES ARE IN BYTES, it doesn't work either.
    The database version is 11.1.0.6.
    Edited by: yuan on May 21, 2010 2:43 AM

    Hi,
    I changed the BYTE in the create table part to CHAR, it still doesn't work. The result is the same. I think the problem is in ACCESS PARAMETERS.
    Any other suggestion?

  • View Object to read data from a java file

    Hi,
    I am using JDeveloper 11.1.1.4 and ADF-BC in my application.
    For one of my view objects , I want the data to be read from a java file which exposes some method to return a collection.
    I cannot use a static view object in this case.
    Please suggest the best way to implement this requirement.Basically build a view object that should read data from a java file.
    Thanks,
    Praveen

    Depending on your use case you can either use a programmatic VO or directly expose the JV class as a data control.
    http://docs.oracle.com/cd/E18941_01/tutorials/jdtut_11r2_36/jdtut_11r2_36.html

  • Problem in reading data from serial port continuously- application hangs after sometimes

    I need to read data from two COM port and order of data appearance from COM port is not fixed. 
    I have used small timeout and reading data in while loop continously . If my application is steady for sometime it gets hangs and afterwards it doesnt receive any data again. 
    Then I need to restart my application again to make it work.
    I am attaching VI. Let me know any issue.
    Kudos are always welcome if you got solution to some extent.
    I need my difficulties because they are necessary to enjoy my success.
    --Ranjeet
    Attachments:
    Scanning.vi ‏39 KB

    billko wrote:
    Ranjeet_Singh wrote:
    I need to read data from two COM port and order of data appearance from COM port is not fixed. 
    I have used small timeout and reading data in while loop continously . If my application is steady for sometime it gets hangs and afterwards it doesnt receive any data again. 
    Then I need to restart my application again to make it work.
    I am attaching VI. Let me know any issue.
    What do you mean, "not fixed?"  If there is no termination character, no start/stop character(s) or even a consistent data length, then how can you really be sure when the data starts and stops?
    I probably misunderstood you though.  Assuming the last case is not ture - there is a certain length to the data - then you should use the bytes at port, like in the otherwise disastrous serial port read example.  In this case, it's NOT disastrous.  You have to make sure that you read all the data that came through.  Right now you have no idea how much data you just read.  Also, if this is streaming data, you might want to break it out into a producer/consumer design pattern.
    Not fixed means order is not fixed, data from any com port can come anytime. lenght is fixed, one com port have 14 byte and other 8 byte fixed..
    Reading data is not an issue for me as it works nice but I have a query that why my application hangs after sometime and stops reading data from COM PORT.
    Kudos are always welcome if you got solution to some extent.
    I need my difficulties because they are necessary to enjoy my success.
    --Ranjeet

  • Reading Data from serial (Comm) Port in developer200 forms 6i

    Dears,
    I have developed an application using Dev2k forms 6i.
    I need to read data from a device (weigh bridge) that is attached to PC on comm port.
    scenario: when a vehicle comes on the Weigh bridge it calculates its weight and send it to the PC on serial port.
    on when-button-pressed event I want to get data into a text field on form.
    If any one has developed such form please help me.
    Thanks and regards

    you can:
    create java class -> wrap plsql -> invoke plsql-code from button trigger
    googling java class instead of creating =)

  • Read data from serial port or TCP port of frontend PC

    Hello Friends,
    I have requirement to read data from device connected to frontend PC which will provide meter reading data.
    Vendor has given me two option.
    1. Device can be connected to seiral port and data transfer will be done through MODBUS RTU protocol.In that case data need to capture from serial port.
    2. Device can be connected to TCP port and Socket program can be provided for data transfer. In that case SAP will act as client and communicate with TCP port.
    There will be multiple workstation with individual meters connected to them.
    I am aware of text file interfacing through front end tools using custom code using VB,JAVA or others.
    Is there any solution availble  to achieve above things using  ABAP other than text file , like direct communication?
    I am using ECC 6.0.

    Hello,
    Socket programming in not available on ABAP, but you may use RFC for the same.
    Use the below links for more details
    [Link 1|http://help.sap.com/printdocu/core/print46c/en/data/pdf/BCFESDE2/BCFESDE2.pdf]
    [Link 2|http://forums.sdn.sap.com/thread.jspa?threadID=1820233]
    Regards,
    Abhishek

  • Failed to read data from report file, failed to read parameter object

    Error message when doing a u201CSchedule List of Valuesu201D
    failed to read data from report file,
    c:\docume~1\user........
    failed to read parameter object
    Earlier in the day it worked just fine nothing had been changed.
    I have admin right on the windows server and in central management console
    Can someone please help with this issue.

    Hi Glenn
    Please let us know the following:
    1.What is the exact version of Crystal Reports Designer?
    2.What is the version of Business objects Enterprise installed on the machine?
    3.Are reports based on Business views,Deski,Webi?
    4.Are the reports migrated from older version of Crystal Reports to new Version?
    Thanks
    Shraddha

  • Problem while reading data from Serial Port

    Hi All,
    I am facing some problem while reading data from Serial Port.
    As per the requirement I am writing the data on Serial Port and waiting for response of that data.
    Notification for data availabilty is checked with method public void serialEvent(SerialPortEvent event) of javax.comm.SerialPortEventListener.
    When we are writing data on the port one thread i.e. "main" thread is generated and when data availability event occures another thread "Win32SerialPort Notification thread" is generated. This creates problem for me as we can't control thread processing.
    So can anybody pls explain me how to overcome this problem?
    Regards,
    Neha

    My Problem is:-
    I am simoultaneouly wrting data on port & reading data from port.
    First I write data on port using outputStream.write() method. Now when target side sends me response back for the request on serial port DATA_AVAILABLE of SerialPortEventListner event occured,we are reading data from serial port.Now till the time we didn't get the response from target next command can't be written on the serial port. When we are writing data on port main thread is executed.Now my problem starts when DATA_AVAILABLE event occured.At this point another thread is created.Due to this my program writes data of next command without reading response of previous command.To solve this prob. I have used wait() & notify() methods as follows.But again due to this my pc hangs after execution of 2 commands. (PC hang in while loop in a code provided below.)
    From SOPs I could figure it out that after 2 commands we are not able to write data on serial port so DATA_AVAILABLE event doesn't occure n pro. goes in wait state.
    Can anybody help me to solve this issue.
    Neha.
    Code:
    public void serialEvent(SerialPortEvent event)
              switch (event.getEventType())
                   case SerialPortEvent.BI:
                   case SerialPortEvent.OE:
                   case SerialPortEvent.FE:
                   case SerialPortEvent.PE:
                   case SerialPortEvent.CD:
                   case SerialPortEvent.CTS:
                   case SerialPortEvent.DSR:
                   case SerialPortEvent.RI:
                   case SerialPortEvent.OUTPUT_BUFFER_EMPTY:
                                 break;
                   case SerialPortEvent.DATA_AVAILABLE:
                        try
                             dataThread = Thread.currentThread();
                             dataThread.setPriority(10);
                             dataAvailable = true;
                                                                                    byte[] tempArray=new byte[availableBytes];
                                        inputStream.read(tempArray);
                                                                       catch (IOException io)
                             SOP(io, "Error in serialEvent callback call for event DATA_AVAILABLE");
    public void  writetoPort(byte[] data) throws IOException
                             outputStream.write(data);
                              while(finalTimeOut >= actualTime)
                            if( ! dataAvailable)
                                    actualTime = System.currentTimeMillis();
                           else
              synchronized (mainThread)
                   mainThread = Thread.currentThread();
                   mainThread.wait();
    public  void sendDatatoUser(byte[] b) throws Exception, HWCCSystemFailure
              obj.returnData(b);
              synchronized(mainThread)
                   mainThread.notify();
                                                           

  • Read data from SAP R/3 Class-System

    Hello,
    first of all sorry when I posted this into the wrong subforum, but I wasn't sure about that. My Question is how to read data from the Classystem I have specified in my ABAP report.
    The goal is to read data from my individual class-system as well as data from MM and write them to a table that is to be read by another report. But right now I can't find information about the class system and abap. Maybe you know some tutorials or blogs about right that topic you can suggest?

    What class system have you specified in your report?
    Normally a class can be used by declaring a variable of type of the class in question, if this class can be instantiated this is. If your class can't be instantiated, but it has only class methods, you can call this method directly.
    But there is a lot more to this ABAP Object Oriented Programming, than just this short explanation. Search on SDN for some ABAP OO Tutorials.
    some links:
    http://help.sap.com/saphelp_nw2004s/helpdata/en/c3/225b5654f411d194a60000e8353423/frameset.htm
    http://www.sapgenie.com/abap/OO/
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/b6cae890-0201-0010-ef8b-f970a9c41d47
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/1591ec90-0201-0010-3ba8-cdcd500b17cf
    Transacation ABAPDOCU.

  • TcpListener not working on Azure: Unable to read data from the transport connection: An existing connection was forcibly closed by the remote host

    Hi Everybody,
    i'm playing a little bit with Windows Azure and I'm blocked with a really simple issue (or maybe not).
    I've created a Cloud Service containing one simple Worker Role. I've configured an EndPoint in the WorkerRole configuration, which allows Input connections via tcp on port 10100.
    Here the ServiceDefinition.csdef file content:
    <?xml version="1.0" encoding="utf-8"?>
    <ServiceDefinition name="EmacCloudService" xmlns="http://schemas.microsoft.com/ServiceHosting/2008/10/ServiceDefinition" schemaVersion="2014-01.2.3">
    <WorkerRole name="TcpListenerWorkerRole" vmsize="Small">
    <Imports>
    <Import moduleName="Diagnostics" />
    <Import moduleName="RemoteAccess" />
    <Import moduleName="RemoteForwarder" />
    </Imports>
    <Endpoints>
    <InputEndpoint name="Endpoint1" protocol="tcp" port="10100" />
    </Endpoints>
    </WorkerRole>
    </ServiceDefinition>
    This WorkerRole is just creating a TcpListener object listening to the configured port (using the RoleEnvironment instance) and waits for an incoming connection. It receives a message and returns a hardcoded message (see code snippet below).
    namespace TcpListenerWorkerRole
    using System;
    using System.Net;
    using Microsoft.WindowsAzure.ServiceRuntime;
    using System.Net.Sockets;
    using System.Text;
    using Roche.Emac.Infrastructure;
    using System.IO;
    using System.Threading.Tasks;
    using Microsoft.WindowsAzure.Diagnostics;
    using System.Linq;
    public class WorkerRole : RoleEntryPoint
    public override void Run()
    // This is a sample worker implementation. Replace with your logic.
    LoggingProvider.Logger.Info("TcpListenerWorkerRole entry point called");
    TcpListener listener = null;
    try
    listener = new TcpListener(RoleEnvironment.CurrentRoleInstance.InstanceEndpoints["Endpoint1"].IPEndpoint);
    listener.ExclusiveAddressUse = false;
    listener.Start();
    LoggingProvider.Logger.Info(string.Format("TcpListener started at '{0}:{1}'", RoleEnvironment.CurrentRoleInstance.InstanceEndpoints["Endpoint1"].IPEndpoint.Address, RoleEnvironment.CurrentRoleInstance.InstanceEndpoints["Endpoint1"].IPEndpoint.Port));
    catch (SocketException ex)
    LoggingProvider.Logger.Exception("Unexpected exception while creating the TcpListener", ex);
    return;
    while (true)
    Task.Run(async () =>
    TcpClient client = await listener.AcceptTcpClientAsync();
    LoggingProvider.Logger.Info(string.Format("Client connected. Address='{0}'", client.Client.RemoteEndPoint.ToString()));
    NetworkStream networkStream = client.GetStream();
    StreamReader reader = new StreamReader(networkStream);
    StreamWriter writer = new StreamWriter(networkStream);
    writer.AutoFlush = true;
    string input = string.Empty;
    while (true)
    try
    char[] receivedChars = new char[client.ReceiveBufferSize];
    LoggingProvider.Logger.Info("Buffer size: " + client.ReceiveBufferSize);
    int readedChars = reader.Read(receivedChars, 0, client.ReceiveBufferSize);
    char[] validChars = new char[readedChars];
    Array.ConstrainedCopy(receivedChars, 0, validChars, 0, readedChars);
    input = new string(validChars);
    LoggingProvider.Logger.Info("This is what the host sent to you: " + input+". Readed chars=" + readedChars);
    try
    string orderResultFormat = Encoding.ASCII.GetString(Encoding.ASCII.GetBytes("\xB")) + @"MSH|^~\&|Instrument|Laboratory|LIS|LIS Facility|20120427123212+0100||ORL^O34^ORL_O34| 11|P|2.5.1||||||UNICODE UTF-8|||LAB-28^IHE" + Environment.NewLine + "MSA|AA|10" + Environment.NewLine + @"PID|||patientId||""""||19700101|M" + Environment.NewLine + "SPM|1|sampleId&ROCHE||ORH^^HL70487|||||||P^^HL70369" + Environment.NewLine + "SAC|||sampleId" + Environment.NewLine + "ORC|OK|orderId|||SC||||20120427123212" + Encoding.ASCII.GetString(Encoding.ASCII.GetBytes("\x1c\x0d"));
    writer.Write(orderResultFormat);
    catch (Exception e)
    LoggingProvider.Logger.Exception("Unexpected exception while writting the response", e);
    client.Close();
    break;
    catch (Exception ex)
    LoggingProvider.Logger.Exception("Unexpected exception while Reading the request", ex);
    client.Close();
    break;
    }).Wait();
    public override bool OnStart()
    // Set the maximum number of concurrent connections
    ServicePointManager.DefaultConnectionLimit = 12;
    DiagnosticMonitor.Start("Microsoft.WindowsAzure.Plugins.Diagnostics.ConnectionString");
    RoleEnvironment.Changing += RoleEnvironment_Changing;
    return base.OnStart();
    private void RoleEnvironment_Changing(object sender, RoleEnvironmentChangingEventArgs e)
    // If a configuration setting is changing
    LoggingProvider.Logger.Info("RoleEnvironment is changing....");
    if (e.Changes.Any(change => change is RoleEnvironmentConfigurationSettingChange))
    // Set e.Cancel to true to restart this role instance
    e.Cancel = true;
    As you can see, nothing special is being done. I've used the RoleEnvironment.CurrentRoleInstance.InstanceEndpoints to retrieve the current IPEndpoint.
    Running the Cloud Service in the Windows Azure Compute Emulator everything works fine, but when I deploy it in Azure, then I receive the following Exception:
    2014-08-06 14:55:23,816 [Role Start Thread] INFO EMAC Log - TcpListenerWorkerRole entry point called
    2014-08-06 14:55:24,145 [Role Start Thread] INFO EMAC Log - TcpListener started at '100.74.10.55:10100'
    2014-08-06 15:06:19,375 [9] INFO EMAC Log - Client connected. Address='196.3.50.254:51934'
    2014-08-06 15:06:19,375 [9] INFO EMAC Log - Buffer size: 65536
    2014-08-06 15:06:45,491 [9] FATAL EMAC Log - Unexpected exception while Reading the request
    System.IO.IOException: Unable to read data from the transport connection: An existing connection was forcibly closed by the remote host. ---> System.Net.Sockets.SocketException: An existing connection was forcibly closed by the remote host
    at System.Net.Sockets.NetworkStream.Read(Byte[] buffer, Int32 offset, Int32 size)
    --- End of inner exception stack trace ---
    at System.Net.Sockets.NetworkStream.Read(Byte[] buffer, Int32 offset, Int32 size)
    at System.IO.StreamReader.ReadBuffer(Char[] userBuffer, Int32 userOffset, Int32 desiredChars, Boolean& readToUserBuffer)
    at System.IO.StreamReader.Read(Char[] buffer, Int32 index, Int32 count)
    at TcpListenerWorkerRole.WorkerRole.<>c__DisplayClass0.<<Run>b__2>d__0.MoveNext() in C:\Work\Own projects\EMAC\AzureCloudEmac\TcpListenerWorkerRole\WorkerRole.cs:line 60
    I've already tried to configure an internal port in the ServiceDefinition.csdef file, but I get the same exception there.
    As you can see, the client can connect to the service (the log shows the message: Client connected with the address) but when it tries to read the bytes from the stream, it throws the exception.
    For me it seems like Azure is preventing the retrieval of the message. I've tried to disable the Firewall in the VM in Azure and the same continues happening.
    I'm using Windows Azure SDK 2.3
    Any help will be very very welcome!
    Thanks in advance!
    Javier
    En caso de que la respuesta te sirva, porfavor, márcala como válida
    Muchas gracias y suerte!
    Javier Jiménez Roda
    Blog: http://jimenezroda.wordpress.com

    hi Javier,
    I changed your code like this:
    private AutoResetEvent connectionWaitHandle = new AutoResetEvent(false);
    public override void Run()
    TcpListener listener = null;
    try
    listener = new TcpListener(
    RoleEnvironment.CurrentRoleInstance.InstanceEndpoints["Endpoint"].IPEndpoint);
    listener.ExclusiveAddressUse = false;
    listener.Start();
    catch (SocketException se)
    return;
    while (true)
    IAsyncResult result = listener.BeginAcceptTcpClient(HandleAsyncConnection, listener);
    connectionWaitHandle.WaitOne();
    The HandleAsync method is your "While (true)" code:
    private void HandleAsyncConnection(IAsyncResult result)
    TcpListener listener = (TcpListener)result.AsyncState;
    TcpClient client = listener.EndAcceptTcpClient(result);
    connectionWaitHandle.Set();
    NetworkStream netStream = client.GetStream();
    StreamReader reader = new StreamReader(netStream);
    StreamWriter writer = new StreamWriter(netStream);
    writer.AutoFlush = true;
    string input = string.Empty;
    try
    char[] receivedChars = new char[client.ReceiveBufferSize];
    // LoggingProvider.Logger.Info("Buffer size: " + client.ReceiveBufferSize);
    int readedChars = reader.Read(receivedChars, 0, client.ReceiveBufferSize);
    char[] validChars = new char[readedChars];
    Array.ConstrainedCopy(receivedChars, 0, validChars, 0, readedChars);
    input = new string(validChars);
    // LoggingProvider.Logger.Info("This is what the host sent to you: " + input + ". Readed chars=" + readedChars);
    try
    string orderResultFormat = Encoding.ASCII.GetString(Encoding.ASCII.GetBytes("\xB")) + @"MSH|^~\&|Instrument|Laboratory|LIS|LIS Facility|20120427123212+0100||ORL^O34^ORL_O34| 11|P|2.5.1||||||UNICODE UTF-8|||LAB-28^IHE" + Environment.NewLine + "MSA|AA|10" + Environment.NewLine + @"PID|||patientId||""""||19700101|M" + Environment.NewLine + "SPM|1|sampleId&ROCHE||ORH^^HL70487|||||||P^^HL70369" + Environment.NewLine + "SAC|||sampleId" + Environment.NewLine + "ORC|OK|orderId|||SC||||20120427123212" + Encoding.ASCII.GetString(Encoding.ASCII.GetBytes("\x1c\x0d"));
    writer.Write(orderResultFormat);
    catch (Exception e)
    // LoggingProvider.Logger.Exception("Unexpected exception while writting the response", e);
    client.Close();
    catch (Exception ex)
    //LoggingProvider.Logger.Exception("Unexpected exception while Reading the request", ex);
    client.Close();
    Please try it. For this error message, I suggest you could refer to this thread (http://stackoverflow.com/questions/6173763/using-windows-azure-to-use-as-a-tcp-server
    ) and this post (http://stackoverflow.com/a/5420788).
    Regards,
    Will
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • Reading Data from a Table With an Expert

    Hi all - I'm trying to write an Expert in OWB that would read data from a table and create a new table based on that information. I have the table creation part down, but how can I read data from a table with an Expert? From what I've read, Experts only deal with metadata, and there is no mechanism in Experts to actually read data in the tables. Does OraTcl work in Experts? Has anyone ever came across this problem, and if so, how did you solve it? Thanks in advance for your time! - Don

    Hi Don
    Can also use Java and JDBC from within Tcl, see the routines in this file below, take modify or whatever;
    http://blogs.oracle.com/warehousebuilder/ombora.tcl
    source <dir>\ombora.tcl
    set g_user scott
    set g_upwd zzzzzz
    set g_hostname localhost
    set g_port 1521
    set g_srvname ora111
    oraconnect $g_user $g_upwd $g_hostname:$g_port:$g_srvname
    oraselect "select * from emp" ""
    As well as dumping the results to stdout (you probably want to comment that part out and change any other part you don't like), g_res is a ResultSet object you can use to do whatever.
    Cheers
    David

  • Error while updating data from DataStore object

    Hi,
    Currently we are upgrading BW3.5 to BI7.0 for technical only,
    we found and errors during process chain run in further processing step. This step is basically a delta loading from DSO to Cube.
    The error message are:
    Error while updating data from DataStore object 0GLS_INV
    Message no. RSMPC146
    Job terminated in source system --> Request set to red
    Message no. RSM078
    That's all no further errors message can be explained clearly here from system.
    I have applied SAP note 1152453 and reactivate the datasource, infosource, and data target.
    Still no help here!?
    Please advise if you encountered these errors before.
    Thanks in advance.
    Regards,
    David
    Edited by: David Tai Wai Tan on Oct 31, 2008 2:46 PM
    Edited by: David Tai Wai Tan on Oct 31, 2008 2:50 PM
    Edited by: David Tai Wai Tan on Oct 31, 2008 2:52 PM

    Hi Vijay,
    I got this error:
    Runtime Errors         MESSAGE_TYPE_X      
    Date and Time          04.11.2008 11:43:08 
    To process the problem further, contact you SAP system       
    administrator.                                                                               
    Using Transaction ST22 for ABAP Dump Analysis, you can look  
    at and manage termination messages, and you can also         
    keep them for a long time.                                   
    Short text of error message:                                             
    No start information on process LOADING                                                                               
    Long text of error message:                                              
      Diagnosis                                                               
          For process LOADING, variant ZPAK_0SKIJ58741F4ASCSIYNV1PI9U, the    
          end should be logged for instance REQU_D4FIDCEKO82JUCJ8RWK6HZ9KX    
          under the log ID D4FIDCBHXPLZMP5T71JZQVUWX. However, no start has   
          been logged for this process.                                       
      System Response                                                         
          No log has been written. The process (and consequently the chain)   
          has been terminated.                                                
      Procedure                                                               
          If possible, restart the process.                                   
      Procedure for System Administration                                                                               
    Technical information about the message:                                 
    Message class....... "RSPC"                                              
    Number.............. 004                                                 
    Variable 1.......... "D4FIDCBHXPLZMP5T71JZQVUWX"                         
    Variable 2.......... "LOADING"                                           
    Variable 3.......... "ZPAK_0SKIJ58741F4ASCSIYNV1PI9U"                    
    Variable 4.......... "REQU_D4FIDCEKO82JUCJ8RWK6HZ9KX" 
    Any idea?

  • Read data from SharePoint using ABAP sql command

    We need to read data from a SharePoint site and update the sap object services with the information. There is a lot of information on how to put data into Sharepoint from SAP, but we need to get data from SharePoint and put it into SAP. Is it possible to retrieve data from SharePoint using sql command in ABAP program? If it is possible, what do we need to do to have SAP recognize where to get the SharePoint data?
    Richard Newman

    Hi Newman,
    You can use native sql in your abap code to read data from SharePoint's database. But I would suggest you to generate a SharePoint webservice which can provide you the neccessary data so that you can consume this webservice in ABAP
    (Will be quite faster than native sql).
    Regards,
    Ozcan.

  • Reading data From XML file and setting into ViewObject to Pouplate ADF UI

    Hi,
    I have following requirement.
    I would like to read data from XML file and populate the data in ViewObject so that the data can be displayed in the ADF UI.
    Also when user modifies the data in the ADF UI, it should be modified back into to ViewObject.
    Here is an example - XML file contains Book Title and Author. I would like to read Book Title and Author from XML file and set it into ViewObject Attribute and then display Book title and Author in ADF UI page. Also when user modifies Book title and Author, I would like to store it back in View Object.
    Please help me with this requirement and let me know if any solution exist in ADF, for populating the ADF UI screen fields with external XML file data.
    Thanks

    Read chapter 42 http://download.oracle.com/docs/cd/E16162_01/web.1112/e16182/bcadvvo.htm of the fusion developer guide
    Section 42.7, "Reading and Writing XML"
    Section 42.8, "Using Programmatic View Objects for Alternative Data Sources"
    Timo

  • Read data from 3 arduino analog pins

    Hi, 
    My name is Jack. I have a question about how to read multiply data from arduino analog inputs in labview. I have tried to read data from 2 pins by using same way (continuous analog samples) and the system works well. However, I failed in reading data from one more pin, no matter I used the same way as to read continuous analog samples or the method to read analog voltage. 
    My idea is to read battery voltage from pin 0, and the transducer voltages from pin 1 and pin 2 and convert them to currents. Pin 1 and Pin 2's signals work well, but pin 0 does not that good.
    Another question is that how to plot data of pin 1 and pin 2 into one waveform chart. I have tried to bundle the two arrays; it didn't work, however.
     Attached is my VI. Thanks for help. 
    Attachments:
    final final project.vi ‏747 KB

    This article presents a procedure for reading the analog ports of Arduino UNO R3 board , on which a Joystick shield was installed. The analog data are related to the position of command and can be monitored from the front panel of our program , for which we use serial communication.
    https://decibel.ni.com/content/docs/DOC-33281
    Atom
    Certified LabVIEW Associate Developer
    Attachments:
    analog_JOYSTICK_ARDUINO.zip ‏1 KB
    cmd arduino JOYSTICK.vi ‏65 KB

Maybe you are looking for