Reagrding write from variable to other...

Hello,
I want to know following difference. In case a), the date from variable v_fromdat exactly get copied into a field of internal table chg_roles-from_dat but in case of b) the v_fromdat gets copied with different format.
a) chg_roles-from_dat = v_fromdat.
b) write v_fromdat to chg_roles-from_dat.
Regards,
Rajesh.

If we have v_formdat = sy-datum than it will:
a) chg_roles-from_dat = v_fromdat.
chg_roles-from_dat  will have 20080814
Here chg_rols-from_dat should be TYPE D.
b) write v_fromdat to chg_roles-from_dat.
chg_roles-form_dat will have 08/14/2008 (based on your date settings MMDDYYYY or DDMMYYYY).
Here chg_roles-form_dat should be type CHAR10
Basically this statement WRITES the data to the target variable as it writes the data to output.
Regards,
Naimesh Patel

Similar Messages

  • How to find the value of a variable in other program

    How to find the value of a variable in other program say I am in a FM and this FM is being called in from other program and I want to know some of the variable details of the program from the FM itself. Imagine if this is a txn. and I need to know the details from some of the programs while executing the same transaction
    Regards
    Vin

    Hi Vinayak,
         you will be having your first program values in internal table or some variables,
        when you are calling the second program you wii use like this,
        SUBMIT <Second Program Name> USING SELECTION-SCREEN '1000'
                           WITH s_emp(second program select-options)   IN t_emp(first program variables)
                           WITH p_chk   EQ t_chk
                           WITH p_r1    EQ t_r1
                           WITH p_month EQ t_month
                           WITH s_cust1 IN t_cust1
                           WITH p_r2    EQ t_r2
                           WITH s_cust2 IN t_cust2
                           WITH s_week  IN t_week
                           AND RETURN.
    you have pas like this to get your first program details.

  • Currency Translation not working with "Time Reference from Variable"

    We have created several Currency Translations using RSCUR with a fixed "Key Date".  All have been working fine until we got the request to allow a variable date for the exchange rate date.  I have built a variable on 0DATE which I am putting a default date value into using user exit.  This default date is the SAME date as the fixed "Key Date" which we have been using.  Unfortunately when we use the "Time Reference from Variable" option and use this new variable, no currency conversion is taking place, instead it only shows the original currency values.  I am 100% sure that my variable is getting a value and it is the same date we are using for the fixed "Key Date" value so both methods should be using the exact same exchange rates.  The documentation that I can find states:
    ●      Time reference: The time reference for the currency translation can be either fixed or variable.
    If the time reference is fixed, the time at which the exchange rate is determined is independent of the data. You have the following options:
    ○       You can establish that the time reference be determined upon translation.
    ○       You can select the current date.
    ○       You can specify a fixed date as the key date.
    ○       You can specify any variable that exists for InfoObject 0DATE.
    ○       You can establish that the query key date be used. This is determined in the query settings.
    In my case I am only switching from option "You can specify a fixed date as the key date"=(Key Date) to "You can specify any variable that exists for InfoObject 0DATE"=(Time Reference from Variable).
    What am I missing?  Any help is appreciated.

    I neglected to mention that we are calling this currency translation through a WAD button using the SET_CURRENCY_TRANSLATION command.  I did do a test by applying the currency conversion within query key figure.  This seems to work.  So it appears the issue is with how the WAD is processing the variable, not the query.  When I display the variable in a drop down item within the WAD it does have the default value that I have assigned in user exit.

  • What key(s) do i type to change language from english to other? i am writing s story in dual languages. i was told to click command and space bar together but it is not working.

    what key(s) do it type to change language from english to other? i am writing a story in dual languages. I was told to click command and space bar together but it is not working.

    Command Spacebar opens Spotlight as you have found out. If you want to change languages you need to say what app you are using to write the story in, I'm guessing you are using Pages or MS Word. If that's the case
    Pages: Open Inspector - Click the T tab - Click Language and change your language.
    MS Word: Tools Menu - Language - Choose your language.

  • Slow performanc​e to read/write shared variables programati​cally

    We are using datasocket read and write functions to read and write shared variables programatically (in the same machine) but we only achieve a performance of aprox. 200 reads/writes per second. We are using Labview 8.6 with DSC.
    Is possible to get better results? That performance is normal?
    Any help would be appreciated. Thank you in advance.

    Hi MMCDAT,
    I think this value can
    be normal as you can see in this link:
    http://zone.ni.com/devzone/cda/tut/p/id/5037
    As you can see, the
    limit for datasocket depends on your Ethernet limitations, even if you as using
    it just in one PC:
    http://digital.ni.com/public.nsf/websearch/6AC9E65​734E53F9A8625672400637ECC?OpenDocument
    You can improve the
    performance changing the update mode or Vis configurations:
    http://digital.ni.com/public.nsf/allkb/F8F7DE98856​B50588625672400648045?OpenDocument
    http://digital.ni.com/public.nsf/allkb/2D9C6D73A16​0537986256B290076456E?OpenDocument

  • How can I put the contents of an array into a set of write local variable clusters?

    I have a set of controls that a user fills in. The controls are clustered by rows, then combined into a 1D array, then written to a file. When I read the file, I want to feed the array back into the clusters with write local variables. Is there a simple way to handle the numerous local variable clusters so I can stuff the array back into them?
    Is there a better way to handle the whole issue of storing and recovering the information?
    The rows are steps in a procedure, and each row (cluster) contains numerical as well as string controls.

    There are many ways of doing this
    You may convert all your data to strings and save as an ascii file (you have to pay attention to the file format, so you can read it properly.
    Or you can use the configuration vi's, it may work in your case.
    or you may use an invoke node to get all controls of the vi's, save it, then read it, without worrying about any format. I have attached a vi that uses this method.
    Attachments:
    Temp.vi ‏52 KB

  • Can't read or write from iPod when it syncs with a big library

    When I try to sync with my 50Gb size library in the iTunes installed on my iBook G4 (10.4.11), it appears "can't read or write from the ipod", in the middle of the synchronization. It starts to do the job very well, but when it has done only 6 or 8 Gb, the process got slower until it appears such message. I have iTunes 7.6 and ipod firmware 1.1. I have tried on Windows and Mac plattforms, trying all the combinations (Mac and/or Win formats) and the trouble persists. The device has only two weeks of use, and it was working perfectly until now. The problem it is the same if I do it manually (no automatic sync). I am not sure if the problem is defective hardware, does anybody have any idea or have similar problem? Thanks.

    Thanks a lot for your answer. The idea of an increasing autoplaylist it is pretty good. I did it, in 5 Gb steps, and in the thrid step (10 Gb done), when it only has copied almost one Gb, the error message pop up again. Before the message appears, iTunes become slower and slower copyng each song until it stops in one song, and after a while, message appears. After, the system come down, almost blocked, and it takes a long until I can mount the ipod again. Of course, ipod restarts automatically and the songs copied in the last step are not there. I was taking care in every moment of the process, avoiding to leave the system suspend alone (and also turning off all the saving energy options). I am now pretty sure that the problem is on the device. Anyway, thank you very much for your valuable ideas.

  • What are Parameters? How are they differenet from Variables? Why can't we use variables for passing data from one sequnece to another? What is the advantage of using Parameters instead of Variables?

    Hi All,
    I am new to TestStand. Still in the process of learning it.
    What are Parameters? How are they differenet from Variables? Why can't we use variables for passing data from one sequnece to another? What is the advantage of using Parameters instead of Variables?
    Thanks in advance,
    LaVIEWan
    Solved!
    Go to Solution.

    Hi,
    Using the Parameters is the correct method to pass data into and out of a sub sequence. You assign your data to be passed into or out of a Sequence when you are in the Edit Sequence Call dialog and in the Sequence Parameter list.
    Regards
    Ray Farmer

  • How to use lengthy query in a "SQL Command from Variable"

    My oracle SQL Query length is more than 14000 characters, so how can i use this for "SQL command from variable".
    Sarvan

    Either create a view or a table valued UDF. Using stored procedure in OLEDB source has some gotchas it will not pick up metadata information by default due to late binding.
    http://consultingblogs.emc.com/jamiethomson/archive/2006/12/20/SSIS_3A00_-Using-stored-procedures-inside-an-OLE-DB-Source-component.aspx
    Please Mark This As Answer if it helps to solve the issue Visakh ---------------------------- http://visakhm.blogspot.com/ https://www.facebook.com/VmBlogs

  • Varying result set and binding parameters in sqlcmd from variable

    SSIS  - Support of Multiple versions of our product
    Our Enterprise Data warehouse consolidates data from multiple data sources.  We have a requirement that we should be able to support data collection from different version of these data sources at the same time.
    Ex. Customer has three different versions of our product installed 7.3,  7.3.1 and 7.3.2. The data warehouse would in this case would be on version 7.3.2, but should be able to collect data from prior versions of the data sources.
    We use stored procedures to collect data from sources into our staging area and then we transform and load it on to the warehouse. The design of SSIS packages are that, there is one main package that executes packages for each table that we collect data
    from the source. The main package is invoked per source that we need to collect data from, if there are three sources at run time there will be three instances of the main package running. These packages run on the warehouse machine to pull the data from the
    source system.
    We would like to maintain one version of these packages on the warehouse and support collecting data from different source versions.
    Challenges
    The signature of stored procedures on the source system has changed between versions
    There are some additional fields returned by these stored procedures in the newer release
     Example
     7.3 version signature :
    [dbo].[PDW_GetMediaAgentSummary](@LastVersionID
    AS BIGINT,
    @InitializeDays as
    INT = 60,
    @NextVersionID AS
    BIGINT OUTPUT)
    7.3 Sp1 version signature:  [dbo].[PDW_GetMediaAgentSummary](@LastVersionID
    AS BIGINT,
    @DataStartDate AS
    DateTime2(3),
    @NextVersionID AS
    BIGINT OUTPUT)
     Also, let us say in 7.3 this stored procedure returned 8 fields and 7.3 sp1 it is returning 10 fields.
    The way we are trying to accommodate is to use “SQLCmd from variable” option in the OLE DB source to cover the signature difference, but this option does not allow us to bind parameters
    to variables to get the output value. The second issue of additional fields (or the lack of additional fields from the 7.3 procedure), we tried to turned off the metadata validation, but we get field not found error at run time when we run the SSIS package
    against 7.3 version. Looks like the only way we could solve is to duplicate the data flow tasks, based on the source version. Looking for better way to do this, since this could go out of control as the number of releases increases.
    Appreciate help on this.

    I suggest you branch your package into one route vs another based on some flag that indicates version the package is connected to then it will execute one stored proc or another, this can be done
    using the Precedence Constraints, or make a wrapper stored proc that hides the data differences between the versions.
    Arthur
    MyBlog
    Twitter

  • Can i write from a URLConnection ?

    Can i write from a URLConnection ?
    I can read but can i write on a txt file ?

    You can upload, just as you would upload from an HTML page with a form and a Submit button. That's what you can do.

  • Scope from variable

    I work with servlets some time, but I don't understand the scope from variable not complete.
    Like in JSP with Beans you can store objects in differnt scope:
    1. request: --> variable within function (get/post)
    2. session: --> HttpSession Object
    3. page: --> private variable in servlet or ServletContext???
    4. application: -->
    every answer is useful
    regards Dietmar

    With tomcat you can set up more contexts for different applications...
    Is the ServletContext different in every application or
    is it the same in the whole servlet container?
    Thanks Dietmar

  • Read and write from access

    I am arun, a beginner in the field of LabVIEW. Now I am trying to read and write data from MS Access with out database connection toolset. How this possible. How I can use activex in Labview for doing this. Please give me some reference materials.

    Hi Arun,
    The following discussion forum talks about the same issue, and provides a good explanation and references for the different options. Also, which version of LabVIEW are you using?
    How to read/write from Access database
    Thanks,
    Lesley Y.

  • How to remove leading zeros from variable

    hi,
       how to remove leading zeros from variable like it_vbap-matnr.
    value in it_vbap-matnr is 000000000000000358
    i want to remove leading zeros so that it become 358
    regards
    deepak

    You can use Function Module <b>'CONVERSION_EXIT_MATN1_OUTPUT'</b>
    This Function Module will eliminate leading Zeros.
    For each MATNR Value read form DB Table,u can eliminate Leading zeros and then modify ur Internal table.
    I think u will not get leading Zeros into utr Internal table when u read from VBAP.
    Bcoz MATNR in VBAP itself have Conversion routine.
    If u r getting leading zeros,U can use following Logic.
    tables:
      vbap.
    data:
       t_vbap like standard table of vbap.
    select matnr
    from vbap
    into corresponding fields of table t_vbap.
    loop at t_vbap into vbap.
      CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT'
          EXPORTING
            INPUT         =  vbap-matnr
          IMPORTING
            OUTPUT        =  vbap-matnr
      modify t_vbap from vbap transporting matnr.
    endloop.
    Hope this will work.....

  • Calling one variable to other variable ( alphanumeric)

    Hi All,
    I have scenario where I am calling one variable to other variable in ODI.
    For example.
    Lets say I have two variable V_SET1 & V_SET2
    V_SET1 :
    Variable type : alphanumeric , Historize,
    Refreshing : SELECT #V_SET1 FROM DUAL to historize value.
    Now I am using V_SET1 in V_SET2
    V_SET2:
    Variable type : alphanumeric , Historize,
    Refreshing :
    select SOURCE_NAME from EXTRACT_PGSQL_DETAIL where OE_DETAILS = # V_SET1
    Both variables are inside scenario I am passing value of V_SET1 at run time as parameter 'TEST'
    V_SET1 is executed sucessfully & TEST is stored is historized
    BUT in V_SET2 V_SET1 value is getting passed in " quotes & i am geeting error of INVALID IDENTIFIER "TEST"
    select SOURCE_NAME from EXTRACT_PGSQL_DETAIL where OE_DETAILS = # V_SET1 ( "TEST") -- error inavlid identifier.
    How can I covert the value of TEST from "TEST" to 'TEST' in second Variable V_SET
    Edited by: neeraj_singh on Jun 24, 2011 3:15 AM

    Hi,
    Try this if not,
    select SOURCE_NAME from EXTRACT_PGSQL_DETAIL where OE_DETAILS = '#V_SET1'
    Thanks,
    Guru

Maybe you are looking for