Runtime error - Time managers workplace
To All Experts,
I configured time managers workplace ... but when i clik on the time managers workplace .. it turrns me into the screen of "RUNTIME ERROR" Can u please tell me wht seeting i changed in GUI so that I can rectify my error.
any documents on it will be great help.
Thanks and Regards
Jaydeep jadhav
conf issue
Similar Messages
-
Runtime error(Time limit exceeds)after executing select query
Dear experts, whenever i executing the select query in this zprogram i am getting runtime error that time limit exceeds.i am using inner join and into table.after that also i am geetting error. how can i resolve it??
SELECT LIKP~VBELN LIKP~WADAT_IST LIKP~VEHICLE_NO LIKP~TRNAME
LIKP~VEHI_TYPE LIKP~LR_NO LIKP~ANZPK LIKP~W_BILL_NO
LIKP~SEALNO1 " Seal NO1
LIKP~SEALNO2 " Seal NO2
LIPS~LFIMG
VBRP~VBELN VBRP~VGBEL VBRP~MATNR VBRP~AUBEL VBRP~FKIMG
VBAK~AUART
VBRK~FKART VBRK~KNUMV VBRK~FKSTO
FROM LIKP INNER JOIN LIPS ON LIKP~VBELN EQ LIPS~VBELN
INNER JOIN VBRP ON LIKP~VBELN EQ VBRP~VGBEL
INNER JOIN VBAK ON VBRP~AUBEL EQ VBAK~VBELN
INNER JOIN VBRK ON VBRP~VBELN EQ VBRK~VBELN
INTO TABLE I_FINAL_TEMP
WHERE LIKP~VSTEL = '5100' AND
LIKP~WADAT_IST IN S_WADAT AND
VBRP~AUBEL IN S_AUBEL AND
VBAK~AUART IN ('ZJOB','ZOR') AND
VBRK~FKART IN S_FKART AND
* VBRK~FKART IN ('ZF8','ZF2','ZS1') AND
VBRK~FKSTO NE 'X'.
When I am debugging the select query.the cursor will not go to next step.after 15-20 minutes i am getting runtime error(time limit exceeds).
how can i resolve it for that scenario??Looks like whole SD flow you trying to fetch in single query
First you check the database statistic of these table are upto date in system ( Check with basis team )
if this query was working fine earlier.
Most of table involved are huge volume tables which queried with any primary key
Any secondary index on created for LIKP on VSTEL WADET ?
My suggestion would be split the selection queries and make use of primary or existing secondary index to fetch the desired result if possible. For testing purpose split the queries and find which is taking more time and which needs index by taking squel trace in ST05.
Also take ST05 trace of this query in debugger ( New debugger -> special tool -> trace > ST05/SE30) -
Query0;Runtime error time limit exceeded,with parallel processing via RFC
Dear experts,
I have created a report on 0cca_c11 cube and while running my report when i give cost center group which contains many cost centers , my report executes for long time and at last gives message
"Error while reading data;navigation is possible" and
"Query0;Runtime error time limit exceeded,with parallel processing via RFC"
please tell me what is the problem and how can i solve this
Regards
ShwetahI,
Execute the Query in RSRT with Execute and Debug option.
Select SQL statements toknow where exactly it's taking time.
Let us know the details once you done.
Reg
Pra -
Runtime Error: "Time out" for RFC.
Hi,
During RFC, I am getting a runtime error stating "Timeout error". Even while the job is run in background I am getting this error. Seems like the time for RFC task is set to 600 secs.
How to resolve this and is there any way we can see time limit set for different tasks?
thanks,
ArunHi,
More info: I am using multithreading or mass processing technique, so the logic has to be written in FM which has RFC enabled. So while the task is in process in background it exceeds the time limit set for RFC i.e 600secs.
Sample code:
CALL FUNCTION 'ZZ_ABC'
STARTING NEW TASK gv_task
DESTINATION IN GROUP gv_grp
PERFORMING rcvb_endprocess ON END OF TASK
EXPORTING
e_batch_date = gv_batch_date
FORM rcvb_endprocess "#EC CALLED
USING gv_task TYPE any. "#EC NEEDED
RECEIVE RESULTS FROM FUNCTION 'ZZ_ABC'
TABLES
t_receivables = it_receivables.
gv_rcvd = gv_rcvd + 1.
ENDFORM. " RCVB_ENDPROCESS -
Runtime error : Time out
Hi experts...
I am trying to execute one program in production.. its giving me runtime error timed out....
I am giving you line on which it is showing runtime error...
Please check it n suggest me how can we optimize this code to avoid the same error...
SELECT afko~aufnr afko~aufpl afko~rueck afpo~matnr
INTO CORRESPONDING FIELDS OF TABLE it_temp_orders
FROM afko
INNER JOIN afpo ON
afpo~aufnr = afko~aufnr
WHERE afko~aufnr IN s_aufnr
AND afko~dispo IN s_dispo
AND afpo~matnr IN s_matnr
AND afpo~dwerk IN s_werks
AND afpo~dauat IN s_auart.
SORT it_temp_orders BY aufnr aufpl matnr rueck.
RegardsHi,
break this into two select queries......
use the below code to do the same....
data : begin of fs_afko
aufnr type afko-aufnr,
aufpl type afko-aufpl,
reuck type afko-reuck,
end of fs_afko.
data : Begin of fs_afpo,
aufnr type afpo-aufnr,
matnr type afpo-matnr,
End of fs_afpo.
data : t_afko type table of fs_afko,
t_afpo type table of fs_afpo.
SELECT aufnr aufpl rueck
INTO TABLE t_afko
FROM afko
WHERE afko~aufnr IN s_aufnr
AND afko~dispo IN s_dispo.
SELECT afpo~matnr
INTO TABLE t_afpo
FROM afpo
FOR ALL ENTRIES IN t_afko
WHERE aufnr = t_afko-aufnr
AND afpo~matnr IN s_matnr
AND afpo~dwerk IN s_werks
AND afpo~dauat IN s_auart.
loop at t_afko into fs_afko.
loop at t_afpo into fs_afpo where aufnr = fs_afko-aufnr.
move-corresponding fs_afko to fs_temp_orders.
move-corresponding fs_afpo to fs_temp_orders.
append fs_temp_orders to it_temp_orders
endloop.
endloop.
Regards,
Siddarth -
every time I try to open itunes I get a message saying "runtime error. An application has made an attempt to load the C runtime library incorrectly. I have already un- and re-installed it, but i get the same message as before. How do i fix this? I don't want to lose my music and would at least want to save that.
Follow the instructions of tt2 given in https://discussions.apple.com/thread/5822086 and note to run as admin
-
Load from ODS into InfoCube gives TIME-OUT runtime error after 10 minutes ?
Hi all,
We have a full load from ODS into InfoCube and it was working fine till the last week upto with 50,000 records. Now, we have around 70,000+ records and started failing with TIME_OUT runtime error.
The following is from the Short Dump (ST22):
The system profile "rdisp/max_wprun_time" contains the maximum runtime of a
program. The current setting is 600 seconds. Once this time limit has been exceeded, the system tries to terminate any SQL statements that are currently being executed and tells the ABAP processor to terminate the current program.
The following are from ROIDOCPRMS table:
MAXSIZE (in KB) : 20,000
Frequency : 10
Max Processes : 3
When I check the Data Packages under 'Details' tab in Monitor, there are four Data Packages and the first three are with 24,450 records. I will right click on each Data Package and select 'Manual Update' to load from PSA. When this Manual Update takes more than 10 minutes it is failing with TIME_OUT again.
How could I fix this problem, PLEASE ??
Thanks,
Venkat.Hello A.H.P,
The following is the Start Routine:
PROGRAM UPDATE_ROUTINE.
$$ begin of global - insert your declaration only below this line -
TABLES: /BIC/AZCPR_O0400, /BIC/AZCPR_O0100, /BIC/AZCPR_O0200.
DATA: material(18), plant(4).
DATA: role_assignment like /BIC/AZCPR_O0100-CPR_ROLE, resource like
/BIC/AZCPR_O0200-CPR_BPARTN.
$$ end of global - insert your declaration only before this line -
The follow definition is new in the BW3.x
TYPES:
BEGIN OF DATA_PACKAGE_STRUCTURE.
INCLUDE STRUCTURE /BIC/CS8ZCPR_O03.
TYPES:
RECNO LIKE sy-tabix,
END OF DATA_PACKAGE_STRUCTURE.
DATA:
DATA_PACKAGE TYPE STANDARD TABLE OF DATA_PACKAGE_STRUCTURE
WITH HEADER LINE
WITH NON-UNIQUE DEFAULT KEY INITIAL SIZE 0.
FORM startup
TABLES MONITOR STRUCTURE RSMONITOR "user defined monitoring
MONITOR_RECNO STRUCTURE RSMONITORS " monitoring with record n
DATA_PACKAGE STRUCTURE DATA_PACKAGE
USING RECORD_ALL LIKE SY-TABIX
SOURCE_SYSTEM LIKE RSUPDSIMULH-LOGSYS
CHANGING ABORT LIKE SY-SUBRC. "set ABORT <> 0 to cancel update
$$ begin of routine - insert your code only below this line -
fill the internal tables "MONITOR" and/or "MONITOR_RECNO",
to make monitor entries
clear DATA_PACKAGE.
loop at DATA_PACKAGE.
select single /BIC/ZMATERIAL PLANT
into (material, plant)
from /BIC/AZCPR_O0400
where CPR_EXT_ID = DATA_PACKAGE-CPR_EXT_ID
and ( MATL_TYPE = 'ZKIT' OR MATL_TYPE = 'ZSVK' ).
if sy-subrc = 0.
DATA_PACKAGE-/BIC/ZMATERIAL = material.
DATA_PACKAGE-plant = plant.
modify DATA_PACKAGE.
commit work.
endif.
select single CPR_ROLE into (role_assignment)
from /BIC/AZCPR_O0100
where CPR_GUID = DATA_PACKAGE-CPR_GUID.
if sy-subrc = 0.
select single CPR_BPARTN into (resource)
from /BIC/AZCPR_O0200
where CPR_ROLE = role_assignment
and CPR_EXT_ID = DATA_PACKAGE-CPR_EXT_ID.
if sy-subrc = 0.
DATA_PACKAGE-CPR_ROLE = role_assignment.
DATA_PACKAGE-/BIC/ZRESOURCE = resource.
modify DATA_PACKAGE.
commit work.
endif.
endif.
clear DATA_PACKAGE.
endloop.
if abort is not equal zero, the update process will be canceled
ABORT = 0.
$$ end of routine - insert your code only before this line -
Thanks,
Venkat. -
ABAP Runtime Error at the time of saving of Document Through CV01N tcode
Dear Experts
We have install seprate DMS Server for storing various documents of different module.
While saving of Document through Transaction CV01N one small screen gets pop up.Which is as follows
Check in Document:KPro
Storage Category Description
ZCITY123 DMS
I am selecting above line from Kpro, then when i click on save system gives ABAP Runtime Error.
Runtime Errors CALL_FUNCTION_NOT_FOUND
Except. CX_SY_DYN_CALL_ILLEGAL_FUNC
Date and Time 21.10.2008 18:35:26
Short text
Function module "PROJECT SYSTEM" not found.
What happened?
The function module "PROJECT SYSTEM" is called,
but cannot be found in the library.
Error in the ABAP Application Program
The current ABAP program "SAPLSDCE" had to be terminated because it has
come across a statement that unfortunately cannot be executed.
I am not understanding why this dump is coming.
How i can come up from this issue.Pls guide me.If any customizing is required pls give the steps
Thanks in Advance.
Regards,
Sandeep TheurkarThere is a programming error somewhere.To get a solution quickly, do as follows:
1. Turn off all badi's, user exits and whatever you have changed in standard SAP.
2. Rerun - if it still fails - search in SAP notes for relevant notes
3. If it doesnt fail - you have an error in your own programming
4. If you are on relevant Support packages etc, send a message to SAP.
Regards,
Espen Leknes -
Runtime Error After Installing Quick Time 7.2 Without Itunes Option
First I could not open my Itunes b/c I had an application error. So I uninstalled Quick Time and reinstalled Quick Time 7.2 (w/o Itunes). Now I have a "Runtime Error: This Application has requested the Runtime to terminate it in an unusual way. Please contact applications support team for more information." I noticed somebody else had this message but I don't know how to uninstall itunes and quick time and try and start all over. Any thoughts??
Okay. let's first try making sure you've removed iTunes and QuickTime completely, as per the following document:
Removing iTunes and QuickTime for Windows
Then once that has been completed, let's try another QuickTime standalone install. (Download and save the QuickTime installer to your desktop. We'll run the install from there rather than online.)
Quicktime 7.2.0 Installers … get the one that doesn’t mention iTunes
Does that install go through okay? if so, do you still get the error message when you try launching QuickTime? -
When starting Firefox I got a message saying
"Runtime Error! This application has requested Runtime to terminate it in an unusual way. Please contact the application's support team for more information."
I have unistalledFirefox several times and reinstalled 3.6 without success.
Thanks for your helpRefer to this article to fix:
iTunes for Windows: "Registry settings" warning when opening iTunes
http://support.apple.com/kb/TS3299 -
Runtime error - C++ each time I close DW3
Recently, every time I close my DW CS3 I get a message with
the screen title "Microsoft Visual C++ Runtime Library." The
message says "Runtime Error! Program: C..." "This application has
requested the Runtime to terminate in an unusual way"
When I click OK I get the following screen title "Adobe
Dreanwevare CS3: Application Error" with the message "The exception
unkown software exception (0x40000015) occued in the application at
location 0x3113b708"
My repeated internt searches under each of those 'numbers'
has been futile.
Does anyone have any ideas?On Mon, 11 Feb 2008, trainerlam wrote
>Recently, every time I close my DW CS3 I get a message
with the screen
>title "Microsoft Visual C++ Runtime Library." The message
says "Runtime
>Error!
>Program: C..." "This application has requested the
Runtime to terminate
>in an unusual way"
>
> When I click OK I get the following screen title "Adobe
Dreanwevare
>CS3: Application Error" with the message "The exception
unkown software
>exception (0x40000015) occued in the application at
location 0x3113b708"
The location hex number is doesn't matter as it's just a
memory location
which will be probably different for every program that hits
the error.
0x4000015 is library error number and you will get some
references, if
you do the search at www.msdn.com. Somewhere in Microsoft
documentation
there will be a description of that error but, even if you
found it, I
can't see that it would help as that error pops up for
different
Microsoft programs. You might get a bit more information by
looking in
the your event viewer, but I doubt it.
http://support.microsoft.com/kb/308427
There doesn't seem to be a common denominator for programs
throwing the
error. Sorry, I can't help you more than that.
Richard Mason
http://www.emdpi.com -
Every time I try to download itunes on my HP computer I get a "Runtime Error R60343". Any suggestions how I can download itunes?
I addressed this with the advice of TuringTest2 see the following link to his solution:-
https://discussions.apple.com/message/24611030#24611030 -
Every time I perform an update I get a Runtime Error message.
Every time I update an add-on or the Firefox browser I get this message:
Microsoft Visual C++ Runtime Library
0 Runtime Error
Program: C :\Program Files\Mozilla Firefox\firefox.exe
R6034
An application has made an attempt to load the C runtime library incorrectly.
Please contact the application’s support team for more information.Find out what that third party software the kext file belongs to and update or use the developers method to uninstall the third party software responsible for it.
I suspect it's a iTunes extension perhaps?
You also can use the manual method of Finder > Go > Computer and opening your drive, then your System/Library/Extensions folder and looking for the file and moving it out onto the desktop, you will need to be in Admin user and use your password, then reboot to clear the random access memory. However this method doesn't remove the parent program you still need to do that.
How to uninstall/install software on your Mac
The kext file wasn't loaded, so it's not running, but removing it from the Extensions folder or uninstalling what put it there will solve your notification problem as that's all it appears to be. -
Runtime Error Dialog at Startup Time
I posted a similar question many months ago, but I still have this problem - even after upgrading to 10.5.6 today. I have no idea where it is coming from or how to get rid of it, but apparently there is something trying to auto-launch in the background every time I restart the computer and the desktop comes up?
The dialog says:
Runtime Error
Location/Volumes/RBUS/REALbasic/REALbasic Xcode/../../Common/relocentry.cpp:3374
Failure Condition: functionPtr == oldRntry->code Failure Message:
Then I have a choice of QUIT or CONTINUE, but of course "CONTINUE" just causes the dilog to keep reappearing.Have you tried uninstalling and reinstalling Real Basic?
http://www.realsoftware.com/download/
If it is something trying to start up then go to :
system Prefs> Accounts> select your account> login items
you should see a list of items which load at start up. You can add or delete items from that list... -
when I open Firefox I have to try several times because a Runtime Error with the program C:\Windows\System32\regsvr32.exe
'''Try the Firefox Safe Mode''' to see how it works there. The Safe Mode is a troubleshooting mode, which disables most add-ons.''
''(If you're not using it, switch to the Default theme.)''
* You can open the Firefox 4.0+ Safe Mode by holding the '''Shift''' key when you use the Firefox desktop or Start menu shortcut.
* Or use the Help menu item and click on the '''Restart with Add-ons Disabled...''' menu item while Firefox is running.
''Don't select anything right now, just use "Continue in Safe Mode."''
''To exit the Firefox Safe Mode, just close Firefox and wait a few seconds before using the Firefox shortcut (without the Shift key) to open it again.''
'''''If it is good in the Firefox Safe Mode''''', your problem is probably caused by an extension, and you need to figure out which one.
Please follow the [[Troubleshooting extensions and themes]] article for that.
''When you figure out what's causing your issues, please let us know. It might help other users who have the same problem.''
Maybe you are looking for
-
Error while creating the delivery in ME2O
Hi Gurus, when the shipping depeartment is trying to create the delivery in ME2o to send the components for subcontractor, we are gettign the error message Essential transfer parameters are missing in record: 000001 Please heklp on this one? and as
-
Bootcamp Issues when attempting to install Windows 7
Please excuse my ignorance.... new to Apple after using Windows for ever. I am attempting to install Windows 7 on my new MacBook Pro 13" purchased 4 days ago. I follow the instructions from following tutorials on UTube however do not get the option t
-
After investing a bunch of time laying out a photo book, I would like to generate a PDF in order to proof it before sending the book to BLURB for printing. After numerous attempts, I am unable to generate a PDF of the book or, by clicking the 'Send B
-
How to connect Material Tracking of PO with handheld device
Hi, Please have a look at my requirement 1. PO needs to be tracked. 2. The tracking device shud be a handheld device which can use the PO number. 3. Can the material be tracked in the PO thru these devices? 4. What are the configurations needed to be
-
Hi After upgrading to OS X Mavericks the Belkin HUB is unstabel makes the mac crash, the external display sometimes blinks lose mous connection and ethernett any tip