Step into step over step out disabled while running

Hello all,
Step into, Step over and Step out are getting disabled whenever I run the sequence. Also Run Button is getting disabled after the execution breaks at break point.
Its very difficult to debug the code because of these isssues.
Is that anything to do with custom process model ? I use a third party process model. But in other PCs which are also using the same process model dont have these issues.

Hey sridar,
Does this happen with a simple sequence file? For example, if you create a new sequence file with only a Message Popup step, set a breakpoint, and then try to debug, does it work properly or do you have the debugging buttons grayed out in this case too?
This is most likely happening because your sequence has multiple threads and not all of the threads are being suspended when you hit the breakpoint. For example, if you have a LabVIEW VI executing in a different thread when the breakpoint is hit, you will not be able to debug unless the LabVIEW thread suspends. Here is a KnowledgeBase article describing this case: http://digital.ni.com/public.nsf/allkb/46D1E157756C37E686256CED0075E156?OpenDocument
It is possible that it is being caused by the process model, but I'd start by trying a very simple sequence file. If that works properly, we know it's something in your larger sequence file. If the simple file also does not allow debugging, we might look into the process model for the issue.
Let us know if you have any further questions!
Daniel E.
TestStand Product Support Engineer
National Instruments

Similar Messages

  • HT204407 Find my Friends app signs me out even while running in background. How can I fix this?

    This happened before and after updating the OS to iOS6. If I open FmF, sign in, it won't stay signed in. I can't use the alerts because after a time, even if I leave the app running in the background, it signs me out. I can still be found by others but can't be informed when friends reach locations.
    My husband and I purchased the same phones at the same time, and his does not have the same problem. We sync using the same Apple ID and share apps. The only issue I can imagine would be a setting that differs between phones but have not been able to nail it down.

    Try creating a passcode for your device in settings. This means you need to enter the passcode before accessing anything on your device, this way you will stay signed into the FmF app even while running in the background and it will not require you to sign in every time you launch the app.  However, once you remove the passcode to your device in settings, the FmF app will again require you to sign in whenever you launch the app. I think this is for security reasons.
    Hope this helps.

  • Time out error while running the FR report on Workspace

    Hi,
    We are working on Hyperion system 9.3.1 financial reporting with Essbase as a data source.
    We have built a report, which has many computation, conditional formatting, suppression condtion.Report has around 100 columns.
    Now when we are try to open this report on workspace, report is throwing the "Server time out" error meassage. error meassage is-
    "The requested item could not be loaded by thr proxy. Timed out".
    Reports are opening fine with less data or if essbase cube doesn't have any data.
    Please suggest us on this issue. Do we need to set any setting at Essbase level or workspace level or any other way.
    Any help will be appriciated.
    Thanks & Regards,
    Mohit Jain

    I would suggest by saying that 100 columns seems quite a lot, you mention there are many computation columns, these should be pushed back onto the server to calculate.
    We have also experienced issues where reports we pulling back lots of columns that were dynamically calculated.
    To narrow down the actual problem you can try the following, the see if the report runs with the change, if not continue with the next steps:
    - remove all formatting from the spreadsheet;
    - remove all calculations from the spreadsheet;
    - see if the report can be built more efficiently, by moving items to Grid POV or using same as, or reordering dimensions in inverse outline order;
    If it still doesn't run, then try removing columns until it can run.
    Cheers, Iain

  • FSCT tool gives a Controller time out while Run Client command

    Hello,
    I am getting a Controller time out error while run client command. I turned on network discovery and start all the services but stil see the time out error;
    DNS Client
    Functional Discovery Resource Publication
    UPnP Device Host
    SSDP Discovery
    I would appreciate prompt assistance on this.
    Thanks,
    Praveen

    Hi,
    Please disable the firewall on my clients, server and turn on "Network discovery" and "File and printer sharing" settings to check the results.
    For more detailed information, please refer to the thread below:
    SCT tool gives a Controller time out while Run Client command
    http://social.technet.microsoft.com/Forums/en-US/a48ae67b-9a9d-4509-9c9c-5d3a468f2cad/fsct-tool-gives-a-controller-time-out-while-run-client-command?forum=fsct
    Best Regards,
    Mandy 
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Problem while running BEx Query

    Hi All,
    I had reqiurement of calculating the difference of the two dates.I calculated Date Difference but I am getting problem when I run the Query.
    The problem is " I am finding the difference between Schedule Line Date and Posting Date. There are some blank spaces in the cube over Schedule Line Date and also over Posting Date. While running the Query Blank Space is taken as # symbol and while calculating the differences it is giving the differences in Lakhs."
    Can anybody help me to solve the problem " To remove the # symbol and calculate the differences properly".
    Thanks in advance.
    With Regards
    Mahi

    Hi,
    Use the Boolean concept like below:
    I hope you are using formula varibles to get Dates into the formula.
    Lets assume fv1 is formulavarible on Schedule line date and FV2 is Formula varible on Posting date.
    (FV1 == '' OR FV2 == '') * 0 + (FV1 <> '' AND FV2 <> '') * (FV1-FV2).
    With rgds,
    Anil Kumar Sharma .P

  • TS2446 My child wants her own Apple ID for her new phone and mac book. Not sure of steps to disable and creat new account while transferring photos etc. thoughts ?

    My child wants her own Apple ID for her phone and mac book. Not sure of steps to disable and create new account while transferring photos etc. thoughts ?

    Welcome to the Apple Community.
    Unfortunately, if Apple simply allowed people to log into different accounts and download content, everyone would be using everyone could share everyone else's content and bypass the need to purchase anything. To protect against this, they limit you to logging into a new account to once every 90 days.
    If two or more of you, have different accounts and use only one computer, you should each have your own user account on the computer, to avoid the need to log in and out of iTunes.

  • What r the steps that involve while v r using DBCONNECT AND UDCONNEC

    Hi All,
    What r the steps that involve while v r using DBCONNECT AND UDCONNECT AND IN WHICH DIFFERENT SCENARIOS V USE THEM.
    REGARDS
    KK

    Hi,
    To Configure UD Connect on the J2EE Server for JDBC Access to External Databases;
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/58f4db47-0501-0010-a2bf-ff01b150fdff
    To create Driver on JDBC side
    http://help.sap.com/saphelp_nw70/helpdata/en/b0/6e62f30cbe9e44977c78dbdc7a6b27/frameset.htm
    Configuring the BI Java Connectors
    http://help.sap.com/saphelp_nw70/helpdata/en/43/e35b3315bb2d57e10000000a422035/frameset.htm
    Then to extract data use this...
    Before you can transfer data from UD Connect sources into BI, you have to generate the metadata (the information about the source object and source object elements) in BI, in the form of a DataSource with a function module for extraction.
    If your dataflow is modeled with objects based on the old concept (InfoSource 3.x, transfer rules 3.x, update rules 3.x), you can generate a DataSource 3.x for transferring data into BI from a database source system.
    Prerequisites
    You have modeled the InfoObjects that you want to use in the InfoSource and the data target or InfoProvider according to the UD Connect source object elements.
    Note the following background information:
    Using InfoObjects with UD Connect
    Data Types and Their Conversion
    Using the SAP Namespace for Generated Objects
    Procedure
    You are in the Modeling InfoSource tree of the Administrator Workbench. First create in InfoSource and activate the communication structure. Then generate the generic DataSource using the wizard in the InfoSource maintenance.
    1. Choose InfoSources ® Your Application Component ® Context Menu (right mouse click) ® Create InfoSource.
    2. Select the type of the InfoSource.
    3. Under InfoSource, enter the technical name of the InfoSource, and assign a description and choose Continue.
    The system creates an InfoSource and shows it in the InfoSource tree under your application components.
    4. In the context menu of the InfoSource, choose Change .
    The communication structure maintenance screen appears.
    5. Using the previously modeled InfoObjects, create the communication structure (see Communication Structure).
    6. Save and activate your communication structure
    7. In the dialog box that follows you will be asked whether you wish to activate the dependent transfer program. Choose No.
    8. In the InfoSource menu, choose Extras ® Create BW DataSource with UD Connect.
    You get to the dialog box where you can assign a UD Connect source object to a DataSource and then generate the DataSource with the extractor. The fields for the DataSource are already being displayed in the table on the left side of the screen. The fields have the same name as the InfoObjects that you have used in the InfoSource.
    9. Select the RFC Destination for the J2EE Engine.
    Make sure that the local server is running. If the local server is running and you cannot open the table for RFC destinations, start the local server again.
    10. Choose the UD Connect Source in which the data that you wish to access is located.
    All available sources that are connected to the J2EE Engine are provided for selection in the input help. n instances are available per adapter.
    11. Select the UD Connect Source Object.
    All available source objects that are available in the selected UD Connect source are provided for selection in the input help. Source objects can be multi-dimensional storage or relational objects.
    The system generates the name of the DataSource in the namespace 6B.
    The DataSource is then replicated in BI.
    The myself system is assigned to the InfoSource as source system as well as the DataSource.
    The system generates a proposal for the transfer rules.
    Since the DDIC structure and the function module are located in the SAP namespace, the following entries can be requested during generation:
    Developer and object key or
    Developer key or
    Object key and
    Transport request
    If you do not make the requested entries, the generated infrastructure is not usable.
    14. Change or complete the transfer rules as needed. For example, if a source object element is not assigned to a unit InfoObject, you can determine a constant for the unit, such as EUR for 0LOC_CURRCY (local currency).
    15. Save and activate your transfer rules.
    Recognizing Manual Entries
    You can enter and change the RFC Destination, UD Connect Source and UD Connect Source Object manually. In order to validate these entries and the ones that depend on them, choose Recognize Manual Entries. For example, if you change the selected RFC destination, all of the field contents (US Connect Source, UD Connect Source Object, list of the source object elements) are invalid. If you choose Recognize Manual Entries, the dependent field contents are initialized and have to be maintained again.
    Result
    You have created the InfoSource and DataSource for data transfer with UD Connect. In the DataSource overview for the myself system, you can display the DataSource under the application components Non-Assigned Nodes.
    When modeling InfoObjects in BI, note that the InfoObjects have to correspond to the source object elements with regard to the type description and length description. For more information about data type compatibility, see Data Types and Their Conversion.
    The following restrictions apply when using InfoObjects:
    Alpha conversion is not supported
    The use of conversion routines is not supported
    Upper and lower case must be enabled
    These InfoObject settings are checked when they are generated.
    Based on the large number of possible UD Connect sources, the most diverse data types are possible in the output system. For this reason, a compatibility check is made at the time of generation of the UD Connect DataSource that is based on the type information supplied by the source systems. This attempts to decrease the probability of errors during the extraction process.
    (Refernce:SAP Notes)
    Hope this helps,
    regards
    CSM Reddy

  • Step out source current

    I am using the NI PXI 7340 and the UMI 7764 and want to connect my 3rd party driver and a stepper motor with Opto-coupler 6N137 which need at least 100mA current for that i want to connect a 47 ohm in series with anode of 6N137 to GND.
    I want to know how much current7340 can drive at the STEP out and DIR ports from the UMI 7764 are connected to my 3rd party driver.
    In 7340 user manual given specification are
    Stepper outputs
    Maximum pulse rate ........................4 MHz (full, half, and microstep)
    Minimum pulse width......................120 ns at 4 MHz
    Step output mode.............................Step and direction or CW/CCW
    Voltage range.................................. 0 to 5 V
    Output low voltage .................. <0.6 V at 64 mA sink
    Output high voltage .................Open collector with built-in
    3.3 kΩ pull-up to +5 V
    vikas

    It is not very unusual that a motor drive unit uses optocouplers as input devices. Drive units usually work with rather high voltages internally (24 to 48VDC) and using optocouplers is the best method to ensure safe operation of the control device (the NI systems) in case of breakdown of internal components.
    But - 100mA drive current is way to high for the 6N137. The data sheet says that you should operate it with 15mA forward current maximum (10mA are recommened for safe operation), 100mA will surely destroy the optocoupler.
    When calculating the series resistor connected to +5V supply you have to take into account 1) the low output voltage of the NI system, 2) the forward voltage of the LED of the optocoupler. 1) is rated at 0.4V, 2) rated at 1.5V (10mA drive current). Let's assume a total of 1.7V to be sure. This voltage has to be subtracted from the supply voltage, and the resistor is calculated for 10mA at the necessary  voltage drop across the resistor. In this case, the voltage drop is 3.3V, and a resistor of 330 ohms will result in a drive current of 10mA. 
    The NI systems can handle up to 64mA in sink mode so everything is safe with 5VDC supply voltage and a resistor of 330 ohms.
    Where did you get this 100mA value from? I have never seen any optocoupler requiring more than 20mA input current.
    6N137 datasheet:
    http://www.datasheetcatalog.net/de/datasheets_pdf/6/N/1/3/6N137.shtml 

  • Steps to follow while creating Database table in notes or paperwork

    what are the steps to follow while creating Database table in notes or paperwork
    Thank you,
    Regards,
    Jagrut Bharatkumar Shukla

    hi,
    1. Goto Transaction SE11.
    2. Enter the table name to be created. It should start with a Y or Z.
    3. Press Create
    4. Enter the Short description for the table
    5. Enter the Delivery class for the table. It can be 'A', 'C' or other.
    6. In the Fields tab, specify the table fields and the corresponding data elements or the built-in data types.
    7. If the table needs to be made a client-depenedent table, the first field should be MANDT.
    8. Goto Technical settings of the table and sepcify the Data Class and Size for the table. Also, there u can specify if buffering for the table should be allowed or not.
    9. Now, activate the table.
    if helpful reward some points.
    with regards,
    Suresh Aluri.

  • Workflow Builder step type 'Loop (While)' missing

    The step type 'Loop (While)' is missing in the workflow builder in both the SWDD and PFTC transactions.  This is happening is a WebAS 640 Support Pack 14 system and a WebAS 700 Support Pack 8 system.
    I have searched in SDN and OSS notes but could not find anything related.
    Are we missing some configuration setting or is this step no longer supported?  Thanks in advance for anyone who can provide some hint.

    How do you create the step?
    Did you try, cliking the cursor on the place you want the step to be, then click on the create button and then select the loop while (maybe your resolution is too small, so that you don't see it appearing)
    Kind regards, Rob Dielemans

  • Bought ipod touch5 from the buyer-and the last owner has not stepped out of his iCloud.ya updated to 7.1.2 and now I need it from appleID Icloud

    bought ipod touch 5 from the buyer-and the last owner has not stepped out of his iCloud.ya updated to 7.1.2 and now I need it from appleID ICloud I solve the problem of activation, if the owner had gone to Iraq? do not offer contact with the old owner as it is silly. a1421 model serial number c3*****4k1
    HELP ME PEOPLE
    <Edited by Host>

    Hey wangyz_david,
    Thanks for the question and detailed information. I understand that you are experiencing issues with your iPhone 5s in relation to battery life. The following website outlines some great tips for maximizing battery performance:
    Apple - Batteries - Maximizing Performance
    http://www.apple.com/batteries/maximizing-performance/
    I also understand that you are interested in performing a recovery mode restore. You can find information regarding recovery mode here:
    If you can't update or restore your iOS device
    http://support.apple.com/kb/HT1808
    Please keep in mind that restoring your backup may cause the issue to be restored as well. For the best isolation steps, you may wish to restore as new:
    iOS: How to back up your data and set up your device as a new device
    http://support.apple.com/kb/HT4137
    After erasing and setting up as a new device, your device is now in a factory configuration. Test to determine if erasing and setting up as a new device resolved the issue. Content on the device may have caused unexpected behavior.
    If the issue is still present, you may want to contact Apple Support.
    Thanks,
    Matt M.

  • How do I disable voice over from my ipad while it's locked?

    How can I disable voice over from my ipad while it's locked? I accidentally activated it on my mum's ipad and now she's panicking! Haven't been able to put in her password so a little bit of help asap would be appreciated. Tried double tapping the passcode in but still didn't work! Thanks

    How did you turn it on, via Settings or a triple-click of the home button ? You could try triple-clicking the home button and see if that turns it off, and if it does you can then change what a triple-click does via Settings > General > Accessibility > Triple-Click Home.
    If that doesn't turn it off then you can either turn it off directly on the iPad (you need to use a tap-to-select and then double-tap to activate/type process and 3 fingered scrolling ; so to type a digit of the passcode tap the digit so that it gets a box around it and then double-tap it to type it) to go into Settings > General > Accessibility and turn VoiceOver 'off', or you can do it by connecting to your computer's iTunes : http://support.apple.com/kb/HT4064

  • Steps involved in MRP run

    Hi! Gurus,
    Can any one list down all the steps involved in MRP run?
    Thank you

    please go through the link for detailed information
    http://help.sap.com/saphelp_470/helpdata/en/f4/7d3f9344af11d182b40000e829fbfe/frameset.htm

  • Time out problem while uploading large bpel processes into oracle soa suite

    Hi everyone,
    I'm using oracle soa suite 10.1.3.4.0 and I'm encountering time out problem while trying to upload a 5MB bpel process into my bpel process server located in the LAN network. The error is coming from apache common file upload.
    Is there a way to increate the connection time out for oc4j to avoid this problem?
    Thanks for any help.
    Regards
    Esfand

    Hi Marc.
    Thanks for your reply. I increased the transaction manager time-out but still I have the same problem. I believe this is something related to oc4j settings and related to upload bpel process. here is my stack trace output:
    79: A problem occured while connecting to server "192.168.0.12" using port "8888": bpel_JazbModaresJadidBPEL_1.0.jar failed to deploy. Exception message is: javax.transaction.RollbackException: Timed out
    at com.oracle.bpel.client.util.ExceptionUtils.handleServerException(ExceptionUtils.java:94)
    at com.oracle.bpel.client.BPELDomainHandle.deploySuitcase(BPELDomainHandle.java:324)
    at com.oracle.bpel.client.BPELDomainHandle.deployProcess(BPELDomainHandle.java:341)
    at deployHttpClientProcess.jspService(_deployHttpClientProcess.java:376)
    at com.orionserver.http.OrionHttpJspPage.service(OrionHttpJspPage.java:59)
    at oracle.jsp.runtimev2.JspPageTable.service(JspPageTable.java:462)
    at oracle.jsp.runtimev2.JspServlet.internalService(JspServlet.java:594)
    at oracle.jsp.runtimev2.JspServlet.service(JspServlet.java:518)
    at javax.servlet.http.HttpServlet.service(HttpServlet.java:856)
    at com.evermind.server.http.ResourceFilterChain.doFilter(ResourceFilterChain.java:64)
    at oracle.security.jazn.oc4j.JAZNFilter$1.run(JAZNFilter.java:400)
    at java.security.AccessController.doPrivileged(Native Method)
    at javax.security.auth.Subject.doAsPrivileged(Subject.java:517)
    at oracle.security.jazn.oc4j.JAZNFilter.doFilter(JAZNFilter.java:414)
    at com.evermind.server.http.ServletRequestDispatcher.invoke(ServletRequestDispatcher.java:623)
    at com.evermind.server.http.ServletRequestDispatcher.forwardInternal(ServletRequestDispatcher.java:370)
    at com.evermind.server.http.HttpRequestHandler.doProcessRequest(HttpRequestHandler.java:871)
    at com.evermind.server.http.HttpRequestHandler.processRequest(HttpRequestHandler.java:453)
    at com.evermind.server.http.HttpRequestHandler.serveOneRequest(HttpRequestHandler.java:221)
    at com.evermind.server.http.HttpRequestHandler.run(HttpRequestHandler.java:122)
    at com.evermind.server.http.HttpRequestHandler.run(HttpRequestHandler.java:111)
    at oracle.oc4j.network.ServerSocketReadHandler$SafeRunnable.run(ServerSocketReadHandler.java:260)
    at oracle.oc4j.network.ServerSocketAcceptHandler.procClientSocket(ServerSocketAcceptHandler.java:234)
    at oracle.oc4j.network.ServerSocketAcceptHandler.access$700(ServerSocketAcceptHandler.java:29)
    at oracle.oc4j.network.ServerSocketAcceptHandler$AcceptHandlerHorse.run(ServerSocketAcceptHandler.java:879)
    at com.evermind.util.ReleasableResourcePooledExecutor$MyWorker.run(ReleasableResourcePooledExecutor.java:303)
    at java.lang.Thread.run(Thread.java:595)
    Caused by: oracle.oc4j.rmi.OracleRemoteException: An exception occurred during transaction completion: ; nested exception is:
    javax.transaction.RollbackException: Timed out
    at com.evermind.server.ejb.EJBTransactionManager.end(EJBTransactionManager.java:152)
    at com.evermind.server.ejb.interceptor.system.TxRequiredInterceptor.invoke(TxRequiredInterceptor.java:57)
    at com.evermind.server.ejb.interceptor.InvocationContextImpl.proceed(InvocationContextImpl.java:119)
    at com.evermind.server.ejb.interceptor.system.DMSInterceptor.invoke(DMSInterceptor.java:52)
    at com.evermind.server.ejb.interceptor.InvocationContextImpl.proceed(InvocationContextImpl.java:119)
    at com.evermind.server.ejb.InvocationContextPool.invoke(InvocationContextPool.java:55)
    at com.evermind.server.ejb.StatelessSessionEJBObject.OC4J_invokeMethod(StatelessSessionEJBObject.java:87)
    at DomainManagerBean_RemoteProxy_4bin6i8.deploySuitcase(Unknown Source)
    at com.oracle.bpel.client.BPELDomainHandle.deploySuitcase(BPELDomainHandle.java:319)
    ... 25 more
    Caused by: javax.transaction.RollbackException: Timed out
    at com.evermind.server.ApplicationServerTransaction.checkForRollbackOnlyWhileInCommit(ApplicationServerTransaction.java:664)
    at com.evermind.server.ApplicationServerTransaction.doCommit(ApplicationServerTransaction.java:273)
    at com.evermind.server.ApplicationServerTransaction.commit(ApplicationServerTransaction.java:162)
    at com.evermind.server.ApplicationServerTransactionManager.commit(ApplicationServerTransactionManager.java:472)
    at com.evermind.server.ejb.EJBTransactionManager.end(EJBTransactionManager.java:137)
    ... 33 more
    Total time: 4 minutes 30 seconds
    The bpel jar file is about 2MB and is uploaded from my machine located in the same LAN.
    Any hints?
    Thanks
    Esfand

  • MDT 2013 - Log out & Disable admin acct?

    How can I log out of Administrator acct and disable it at the end of Lite Touch Deployment?

    Add a step to disable the admin account with this command : net use administrator /active:no, and then add a restart computer. Good luck.
    Ryan
    edit^ net user administrator /active:no
    Thanks Ryan,

Maybe you are looking for

  • Permission problems after upgrade to 10.5 on early Power PC G5 Tower

    Permissions problems after upgrading to 10.5 on a client power PC (early) G5 tower. Problems include folders that are created on XServe via this client do not allow any one else including this client to access. All other clients running 10.5, which h

  • Why do Firefox page icons not display properly?

    hi there, I have a problem which is only happening in Firefox (26). Which is that page icons don't seem to display and show as a default icon. This makes it hard to use some sites which don't have associated text with the button. I have attached an i

  • Mistake in Oracle book ?

    Hi. In Oracle books 10g Certification All in One Exam Guide I found propably a bad answear for one of a review questions. The question was : Which line of code will cause the following SQL statement to fail ? 1 Create bigfile tablespace ocp10gdata 2

  • Errors -1450 and -10000 when trying to download music.

    Can't contact Apple via Express Lane as the page has errors.  Have tried everything!  Please help!  Error -1450 says it is an unknown error and -10000 says the file is corrupt.  Have tried downloading again, and rebooting PC but nothing.  Have report

  • TRIGGER a view for keeping automatically ip connection

    Hi to all, i've founded that this query give you the ip of current machine: select sys_context('userenv','ip_address') from dual; But this is not my purpose or better: the best solution i see for my need would be to trigger an internal table insertin