Tag Query Fatal Error

I'm wanting to send an email if a tag query fails (Failures could include, can't connect to the data server, can't find tag names, etc).  I'd like to include the reason for the failure in the email message.
The 'Data Query' help screen for the 'Success' property says 'Evaluates to true if the query executes without a fatal error. If false, the fatal error message can be accessed with the following XPATH: [ActionName].Results{/Rowsets/FatalError}.'
I can't find a 'Fatal error' entry under Rowsets, only 'DateCreated', 'EndDate', 'StartDate', and 'Version'.  I can find a 'Fatal Error' entry under Rowsets in a SQL query but not a Tag query.  Am I missing something?
I'm running MII 12.0.4
Thanks for the help!
David Macindoe

You'll see the Rowsets/FatalError syntax here:  /XMII/Illuminator?Server=Simulator&Mode=Foo&Content-Type=text/xml
An easy trick to help with your linking, just add another name/value pair to the Config Dialog of Mode and Foo, then say yes when it prompts for the sample xml.  This way you'll see it while linking, but don't forget to remove this line when you're done.
Regards,
Jeremy

Similar Messages

  • Tag Query error when assigning mode in Link Editor

    Hi,
    I am receiving the following error when I run a transaction that contains a Tag query.  In my transaction I have set the tag query mode to be defined by a local property via the link editor.  Then when I execute the transaction I get the following error:
    "[ERROR] [TAG_QUERY_WRITE_TAG]com.sap.xmii.Illuminator.logging.LHException: Mode parameter was not found or is malformed"
    I am on version 12.1.8 Build(43).
    I import the project into MII 12.1.4 Build(53) and the transaction works as expected.
    In the new verson of MII is there a bug utilizing the link editor to set mode?  Or is there a specific way it wants the mode linked. (e.g. specific case)
    Additional details:
    I am trying to use the CurrentWrite mode.  I have tried setting Current mode via the link editor and that isn't working either. 
    Any suggestions?
    Thanks,
    Justin

    Hi Mike,
    Please correct me if I understand the logic incorrectly.  But here is what I am thinking....
    I have configured my transaction to have this flow:
    String_List_To_XML_Sequence --> Repeater_TagValues  -->  TAG_QUERY_WRITE_TAG
    The String_List_To_XML_Sequence would contain String_List_To_XML_Parser_TagValues & String_List_To_XML_Parser_TagNames.
    With this flow the logic would say that I will be running a seperate tag query for each tag value.  So if I have 100 tag values that I want to send, I will run 100 tag queries.  This doesn't seem the most efficient.  Also if this is how you were thinking I would configure the transaction then I could use the following links:
    Target Xpath: TAG_QUERY_WRITE_TAG.TagValue.1
    Expression: String_List_To_XML_Parser_TagValues.Output{/Rowsets/Rowset/Row[#Repeater_TagInput.CurrentItem#]/Item}
    Target Xpath: TAG_QUERY_WRITE_TAG.TagName.1
    Expression: String_List_To_XML_Parser_TagNames.Output{/Rowsets/Rowset/Row[#Repeater_TagInput.CurrentItem#]/Item}
    With this configuration updating 10 tags takes 2 seconds:
    [INFO] Statistics [Load = 35 ms msec, Parse = 35 ms, Execution = 2015 ms, Total = 2067 ms]
    With my old configuration updating 10 tags took 700 ms. (original transaction on 12.1.4 Build (53)
    [INFO] Statistics [Load = 11.137 msec, Parse = 224.113 msec, Execution = 451.78 msec, Total = 736.62 msec]
    Please let me know if I interpreted your thoughts incorrectly.
    If there is a way to utilize only 1 Tag Query, then I am not sure how the transaction flow should be configured.
    Thanks for your time,
    Justin
    Edited by: Justin M Brown on Jul 14, 2011 7:29 PM
    Edited by: Justin M Brown on Jul 14, 2011 7:33 PM

  • Tag Query Error

    Hi,
    I am executing a tag query and I keep getting the following error -
    OperationList [ERROR] - Error Message: Pending requests found, current request will be retried at a later date
    OperationList [ERROR] - Error updating
    com.sap.xmii.applet.common.ResultModelException: Error Message: Pending requests found, current request will be retried at a later date
         at com.sap.xmii.applet.common.BaseApplet.getResultModel(BaseApplet.java:1089)
    Can somebody explain what would be the cause of such an error and how to fix it?
    Regards,
    Chanti.

    Actually, they have to be run in isolation because I can't load both projects in the OPC server at the same time. So, I can run the related MII applications only one at a time. But heres something I found in the UDS logs -
    [P:4192, T:5000,       UDS, ] 0x0     HRESULT: 0x80070057 [Invalid at the top level of the document.
    ]     [Connection.cpp @ 1024, CLHOpcDaConnection::FinalGetMetadata]
    [P:4192, T:5000,       UDS, RETHROW] 0x0     Rethrowing exception.     [Connection.cpp @ 1130, CLHOpcDaConnection::FinalGetMetadata]
    [P:4192, T:5000,       UDS, RETHROW] 0x0     Rethrowing exception over COM.     [tagUtil/lhds2Connection.h @ 1427, lhds::LHDSConnectionImpl<class CLHOpcDaConnection>::GetMetadata]
    [P:4192, T:5000,       UDS, ] 0x0     Caught exception over a COM boundry.     [tagUtil/lhds2NamespaceMode.h @ 174, lhds::LHDSTagListModeImpl<class CLHOpcDaDSTagList>::LookUpDescription]
    [P:4192, T:5000,       UDS, HANDLED] 0x0     Handled exception.     [tagUtil/lhds2NamespaceMode.h @ 177, lhds::LHDSTagListModeImpl<class CLHOpcDaDSTagList>::LookUpDescription]
    Does it make sense?

  • Error using a tag query

    We have a tag query that works in our sandbox environment, but not in dev.  I loaded the same JDBC drivers on both systems.
    The project was exported from the sandbox, and imported into dev.
    I have verified the Data Server set up is identical in both environments.  Connection status in both environments is identical - running, same number of connections, etc.
    When I try to run the query on sandbox in workbench, the query returns data.  I get this error on the dev system -
    SQL error has occurred on query java.sql.SQLException: [Microsoft][SQLServer 2000 Driver for JDBC][SQLServer]Invalid object name 'tag'.
    Detailed error -
    java.lang.Exception: SQL error has occurred on query [Microsoft][SQLServer 2000 Driver for JDBC][SQLServer]Invalid object name 'publicgrouptag'.
         at com.sap.xmii.Illuminator.gui.workbench.populators.IlluminatorPopulator.get(IlluminatorPopulator.java:114)
         at com.sap.xmii.Illuminator.gui.workbench.populators.TagListPopulator.get(TagListPopulator.java:47)
         at com.sap.xmii.Illuminator.gui.workbench.components.desktop.custom.TagQueryBuilderPanel$6.construct(TagQueryBuilderPanel.java:723)
         at com.sap.lhcommon.gui.ThreadCreator$2.run(ThreadCreator.java:94)
         at java.lang.Thread.run(Unknown Source)
    Any suggestions??

    One of your included JDBC driver archives has a class that matches the path provided by the JDBCDriver setting for the data server (likely the sqljdbc.jar file).
    If you take the JDBCDriver setting: 
    com.microsoft.sqlserver.jdbc.SQLServerDriver
    and replace the periods for sub directories and add a .class on the end you'll have:
    com\microsoft\sqlserver\jdbc\SQLServerDriver.class
    So if you unpacked the jar file you'd find this java class (and the other ones included with the driver).
    Do you get the same error about 'publicgrouptag' and 'tag' objects when you test a tag query request for GroupList mode?  These tables/views would be used by the underlying queries used to populate the tag details tab in the WB.  Do you see these tables or view within the SQL Server?  Does the sa user have appropriate permissions?

  • MII 11.5 and PCo 2.1 and Tag Query Error

    Hi,
    I have KEPWare OPC server configured with a single tag, and with the OPC Client open.  I have PCo 2.1 configured with a single agent, and 'legacy' ticked with port 9001.  I have a UDS connector pointing to port 9001, and a tag query in 'currentwrite' mode, and can successfully write a value from the query editor (within MII 11.5) to KEPWare, when tested directly within the MII query editor.
    However, when I call the same tag query from within an MII transaction, and set 'TagName.1' and 'TagValue.1' to the values I want, I get the following error:
    "An item with the same key has already been added. at SAP.Manufacturing.Connectivity.Protocol.Custom.PCoQueryRequestHandler.ProcessRequest(Object handler)"
    I see this error in the PCo log.
    Interesting thing is, that within the transaction editor, when I select the underlying tag query, and the editor asks to generate the XML, and I say Yes, the underlying tag query runs fine (I can see the value getting updated within KEPWare).
    I've also tried with/without subscription items in PCo, plus different settings for 'Cache Mode' in PCo, plus using fully qualified tag name (ie: channel.device.tag as KEPWare sees it), etc, but in all cases I get the above error.
    Any ideas?

    Hi Diana,
    I upgraded to PCo V2.1.4.2, still same issue.  And yes, the data server (UDC) is checked as "Writable"!!
    As mentioned, the tag query runs fine in both "Current" mode and "CurrentWrite" mode.  Only when I call the same query from a transaction do I see this error.  Excerpt from Runner Log below;
    2011-02-23 15:20:32,390 [ServletExec: request: time=1298434832343, uri=/Lighthammer/Runner]
    ERROR  Runner - [9FA68944-67CE-824D-3FA6-D96023119ECE][ERROR]:
    IlluminatorQuery: An item with the same key has already been added. TMP0794C967-0F69-8F04-568C-CD037815D1D0
    2011-02-23 15:20:32,453 [ServletExec: request: time=1298434832343, uri=/Lighthammer/Runner]
    ERROR  Runner - [9FA68944-67CE-824D-3FA6-D96023119ECE][ERROR]:
    ACTION FAILED: End Action IllumTagQuery_0 : () TMP0794C967-0F69-8F04-568C-CD037815D1D0
    If I leave the transaction Tag Query action (that calls the underlying tag query) without any assignment to TagValue.1, then there is no error, and the error as set in the aunderlying tag query is used.  But as soon as I assign values to TagValue.1 inside the transaction, I get the error.  I've tried passing a value via a local paramater etc, same issue.
    Regards
    Kevin.

  • Error while running ejbc. Fatal error from EJB Compiler ---- Error while pr

    Hi!
    I was deploying a test application for a session bean with sun 1 studio 5 and I started getting this message while deploying.
    I had tested the bean previously and I had no problems.
    I found this in the sun app server 7 release notes, but I don't understand what I'm supposed to do...
    "Deployment of CMP beans fails.
    The following error is thrown because there are no <query-params> entries in the container-managed persistence (CMP) bean in sun-ejb-jar.xml file:
    Error while running ejbc. Fatal error from EJB Compiler ---- Error while processing CMP beans.
    Solution
    Even if it isn't necessary for the CMP beans, add the query-params tag for finders in the sun-ejb-jar.xml file with the empty parameters."
    Here is my sun-ejb-jar.xml file:
    <?xml version="1.0" encoding="UTF-8"?>
    <!DOCTYPE sun-ejb-jar PUBLIC "-//Sun Microsystems, Inc.//DTD Sun ONE Application Server 7.0 EJB 2.0//EN" "http://www.sun.com/software/sunone/appserver/dtds/sun-ejb-jar_2_0-0.dtd">
    <sun-ejb-jar>
    <enterprise-beans>
    <name>GestorDoBanco_EJBModule</name>
    <ejb>
    <ejb-name>Cliente</ejb-name>
    <jndi-name>ejb/Cliente</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/Cliente.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>ClienteAssociadoAConta</ejb-name>
    <jndi-name>ejb/ClienteAssociadoAConta</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/ClienteAssociadoAConta.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>Conta</ejb-name>
    <jndi-name>ejb/Conta</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/Conta.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>GestorDoBanco</ejb-name>
    <jndi-name>ejb/GestorDoBanco</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    </ejb>
    <ejb>
    <ejb-name>MensagemM003</ejb-name>
    <jndi-name>ejb/MensagemM003</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/MensagemM003.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>MensagemM003Rejeitada</ejb-name>
    <jndi-name>ejb/MensagemM003Rejeitada</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/MensagemM003Rejeitada.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>MensagemM012</ejb-name>
    <jndi-name>ejb/MensagemM012</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/MensagemM012.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>MensagemM012Rejeitada</ejb-name>
    <jndi-name>ejb/MensagemM012Rejeitada</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/MensagemM012Rejeitada.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>MensagemM103</ejb-name>
    <jndi-name>ejb/MensagemM103</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/MensagemM103.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>MensagemM112</ejb-name>
    <jndi-name>ejb/MensagemM112</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/MensagemM112.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>Registo</ejb-name>
    <jndi-name>ejb/Registo</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/Registo.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>TransaccaoConfirmada</ejb-name>
    <jndi-name>ejb/TransaccaoConfirmada</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/TransaccaoConfirmada.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>TransaccaoFinalizada</ejb-name>
    <jndi-name>ejb/TransaccaoFinalizada</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/TransaccaoFinalizada.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <ejb>
    <ejb-name>TransaccaoIniciada</ejb-name>
    <jndi-name>ejb/TransaccaoIniciada</jndi-name>
    <pass-by-reference>false</pass-by-reference>
    <cmp>
    <mapping-properties>pcImpl0/moduleComp1/Data/TransaccaoIniciada.mapping</mapping-properties>
    </cmp>
    <refresh-period-in-seconds>600</refresh-period-in-seconds>
    </ejb>
    <pm-descriptors>
    <pm-descriptor>
    <pm-identifier>SunONE</pm-identifier>
    <pm-version>1.0</pm-version>
    <pm-class-generator>com.iplanet.ias.persistence.internal.ejb.ejbc.JDOCodeGenerator</pm-class-generator>
    <pm-mapping-factory>com.iplanet.ias.cmp.NullFactory</pm-mapping-factory>
    </pm-descriptor>
    <pm-inuse>
    <pm-identifier>SunONE</pm-identifier>
    <pm-version>1.0</pm-version>
    </pm-inuse>
    </pm-descriptors>
    <cmp-resource>
    <jndi-name>mysqlpmanager</jndi-name>
    <default-resource-principal>
    <name>bes</name>
    <password>besbes</password>
    </default-resource-principal>
    </cmp-resource>
    </enterprise-beans>
    </sun-ejb-jar>
    Thanks in advance for any help.
    Nuno

    http://docs.sun.com/source/817-2175-10/decmp.html
    Please go to the above docs and look thru the examples given in it.
    Example 2
    This query returns all products in a specified price range. It defines two query parameters which are the lower and upper bound for the price: double low, double high. The filter compares the query parameters with the price field:
    "low < price && price < high"
    The finder element of the sun-ejb-jar.xml file would look like this:
    <finder>
    <method-name>findInRange</method-name>
    <query-params>double low, double high</query-params>
    <query-filter>low < price && price &lt
    high</query-filter
    </finder>
    I hope this hepls. In your case u just have to make it null.

  • A fatal error occurred while creating an SSL client credential. The internal error state is 10011.

    Need help.  I have my pilot lync 2013 pool up (in coexistence with 2010 production environment) and can log into Lync 2013 environment with a lync 2010 client but am not able to with a lync 2013 client.  It just prompts for password but will not
    take it. I'm sseeing this on my front end server multiple times:
    A fatal error occurred while creating an SSL client credential. The internal error state is 10011.
    Came across this http://www.logicspot.net/index.php?id=50 and tried disabling TLS 1.2, which I did and verified but yet the issue still exists.
    All my certs are good coming from internal CA.  My signin logs show below but keep in mind, this works just fine if using a 2010 lync client to my lync 2013 servers.  Issue only occurs when trying to connect using a lync 2013 client.
    1 Login: FAIL (hr = 0x1) 
    this request needs authentication, trying webticket from: https://domain.com/WebTicket/WebTicketService.svc
    1.1 Get-NewWebTicket: FAIL (hr = 0x1) 
    CLogonCredentialManager::QueryForSpecificCreds() Credential user 0x069B64A0 id=15 querying for specific credentials, credSuccess=2, targetName=Microsoft_OC1:[email protected]:specific:LAD:1
    1.1.1 ExecuteWithMetadataInternal: FAIL (hr = 0x3d0000) 
    Executing wws method with windows auth auth, asyncContext=0A4FC348,
     context: WebRequest context@ :173931816
      MethodType:4
      ExecutionComplete? :1
      Callback@ :0A5A1864
      AsyncHResult:80f10041
      TargetUri:https://domain.com/WebTicket/WebTicketService.svc
      OperationName:http://tempuri.org/:IWebTicketService
     Error:
    There was an error communicating with the endpoint at 'https://domain.com/WebTicket/WebTicketService.svc'.
    The server returned HTTP status code '401 (0x191)' with text 'Unauthorized'.
    The requested resource requires user authentication.
    1.1.2 ExecuteWithWindowsOrNoAuthInternal: PASS
    1.1.3 ExecuteWithWindowsOrNoAuthInternal: FAIL (hr = 0x3d0000) 
    Executing wws method with windows auth auth, asyncContext=0A4FC348,
     context: WebRequest context@ :173931816
      MethodType:4
      ExecutionComplete? :1
      Callback@ :0A5A1864
      AsyncHResult:80f10041
      TargetUri:https://domain.com/WebTicket/WebTicketService.svc
      OperationName:http://tempuri.org/:IWebTicketService
     Error:
    There was an error communicating with the endpoint at 'https://domain.com/WebTicket/WebTicketService.svc'.
    The server returned HTTP status code '401 (0x191)' with text 'Unauthorized'.
    The requested resource requires user authentication.
    1.1.4 ExecuteWithWindowsOrNoAuthInternal: FAIL (hr = 0x3d0000) 
    Discovery task(0A4FF830) sent to URL http://domain.com completed with hr=0x80f10045
    1.1.5 ExecuteWithWindowsOrNoAuthInternal: FAIL (hr = 0x3d0000) 
    Executing wws method with windows auth auth, asyncContext=0A4FC348,
     context: WebRequest context@ :173931816
      MethodType:4
      ExecutionComplete? :1
      Callback@ :0A5A1864
      AsyncHResult:80f10041
      TargetUri:https://domain.com/WebTicket/WebTicketService.svc
      OperationName:http://tempuri.org/:IWebTicketService
     Error:
    There was an error communicating with the endpoint at 'https://domain.com/WebTicket/WebTicketService.svc'.
    The server returned HTTP status code '401 (0x191)' with text 'Unauthorized'.
    The requested resource requires user authentication.
    1.1.6 ExecuteWithWindowsOrNoAuthInternal: FAIL (hr = 0x3d0000) 
    CLogonCredentialManager::QueryForSpecificCreds() Credential user 0x069B64A0 id=15 querying for specific credentials, credSuccess=2, targetName=Microsoft_OC1:[email protected]:specific:LAD:1
    Rich

    Hi,
    Please check the server role and Web Services for Internet Information Services (IIS) are set correctly.
    For the detailed IIS configuration, please check:
    http://technet.microsoft.com/en-us/library/gg412871.aspx
    As Lync client 2013 attempt to query in order to perform autodiscover of the Lync registration server. First
    lyncdiscoverinternal.<sipdomain> Host (A) record and then
    lyncdiscover.<sipdomain> Host (A) record. If neither of these records are resolvable then the legacy DNS SRV and A record fall-back process is used. So make sure you have add the two A record in DNS server.
    More details:
    http://blog.schertz.name/2012/12/lync-2013-client-autodiscover/
    Note: Microsoft is providing this information as a convenience to you. The sites are not controlled by Microsoft. Microsoft cannot make any representations regarding the quality, safety, or suitability of any software or information found there. Please make
    sure that you completely understand the risk before retrieving any suggestions from the above link.
    Best Regards,
    Eason Huang
    Eason Huang
    TechNet Community Support

  • Fatal Error while retrieving data from Visual Fox Pro using OLE-DB UDS

    Hello all,
    in a customer project we connected a Visual Fox Pro Database via OLE-DB UDS.
    Whenever data is retrieved, a fatal error shows up:
    Fatal Error: Error occurred while processing data stream, null
    Although the data is retrieved correctly!
    MII used: 11.5
    UDS-Server: xMII OLE DB UDS, version 4.0.1.10
    This is the log from the UDS-Server:
    [02/29/2008-11:22:40.195] oleDB [P:4404, T:4792, Framework,   ERROR] 0x0      {extra params}: {5}     [LHDSChannelHandler.cpp @ 488, CLHDSChannelHandler::ExecuteIOCP]
    [02/29/2008-11:22:40.195] oleDB [P:4404, T:4792, Framework,   ERROR] 0x17009     Exception occured: pid = 5, original = 5, data = <ExecutionContext><param name="MODE" value="QUERY"/><param name="QUERY" value="SELECT artikelnr FROM artikel "/><param name="ENDDATE" value="1204280560164"/><param name="ROWCOUNT" value="100"/><param name="STARTDATE" value="1204276960164"/></ExecutionContext>.     [LHDSChannelHandler.cpp @ 493, CLHDSChannelHandler::ExecuteIOCP]
    ********** Start of Exception Stack Trace **********
         1)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792,       UDS, ] 0x0     HRESULT: 0x80004005 [Unspecified error]     [BaseOleDbMode.h @ 1133, BaseOleDbMode<class COleDbQuery>::ProcessDynamicResults]
         2)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792,       UDS, RETHROW] 0x0     Rethrowing exception.     [BaseOleDbMode.h @ 1211, BaseOleDbMode<class COleDbQuery>::ProcessDynamicResults]
         3)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792,       UDS, RETHROW] 0x0     Rethrowing exception.     [Query.cpp @ 107, COleDbQuery::ExecuteOleDbMode]
         4)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792,       UDS, RETHROW] 0x0     Rethrowing exception.     [BaseOleDbMode.h @ 381, BaseOleDbMode<class COleDbQuery>::ExecuteMode]
         5)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792,       UDS, RETHROW] 0x0     Rethrowing exception over COM.     [LHDSUtil.h @ 1086, lhds::LHDSModeImpl<class COleDbQuery,struct ILHDSMode>::Execute]
         6)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792,       UDS, RETHROW] 0x0     Rethrowing exception.     [LHDSUtil.h @ 1124, lhds::LHDSModeImpl<class COleDbQuery,struct ILHDSMode>::Execute]
         7)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792, Framework, RETHROW] 0x0     Rethrowing exception over COM.     [LHDSDispatcher.cpp @ 135, CLHDSDispatcher::CallMode]
         8)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792,       UDS, RETHROW] 0x0     Rethrowing exception over COM.     [LHDSUtil.h @ 893, lhds::LHDataServerImpl<class CLHOleDbDataServer>::Execute]
         9)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792, Framework, ] 0x0     Caught exception over a COM boundry.     [LHDSChannelHandler.cpp @ 566, CLHDSChannelHandler::OnExecute]
         10)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792, Framework, RETHROW] 0x0     Rethrowing exception.     [LHDSChannelHandler.cpp @ 574, CLHDSChannelHandler::OnExecute]
         11)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792, Framework, RETHROW] 0x0     Rethrowing exception.     [LHDSChannelHandler.cpp @ 502, CLHDSChannelHandler::ExecuteIOCP]
         12)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792, Framework, RETHROW] 0x0     Rethrowing exception over COM.     [LHDSChannelHandler.cpp @ 189, CLHDSChannelHandler::Execute]
         13)     [02/29/2008-11:22:40.210] oleDB [P:4404, T:4792,      Host, HANDLED] 0x0     Handled exception.     [ThreadPool.cpp @ 228, ThreadPool::ThreadProc]
    ************** End of Exception Trace **************
    Any help is very much appreciated.
    Regards,
    Matthias
    Edited by: Matthias Wald on Feb 29, 2008 12:12 PM

    Hi Salvatore,
    tried your suggestian but no luck, same error.
    I checked the Version. It shows 4.0.1.10.
    Is there a later version available?
    UDS Settings are (apologize any misspellings):
    Collect Requests                              false
    Log Level                                         Info
    Maximum Concurrent Connections    1000
    Pool Size                                         5
    Port                                                 8087
    Runtime Mode                                  Service
    Service Dependencies                       Eventlog
    Service Passowrd                              *******
    Service Startup                                 Manual
    Service User                                     .\LocalSystem
    Shutdown Timeout                            10
    Stack Size                                       0
    Threading Model                               MTA
    Trusted Requesters                         
    Use IOCP                                        true
    Connection String                            Provider=VFPOLEDB.1;Data Source=D:\Daten;Mode=Share Deny None;Extended Properties="";User ID="";Password="";Mask Password=False;Cache Authentication=False;Encrypt Password=False;Collating Sequence=MACHINE;DSN="";DELETED=True;CODEPAGE=1252;MVCOUNT=16384;ENGINEBEHAVIOR=90;TABLEVALIDATE=3;REFRESH=5;VARCHARMAPPING=False;ANSI=True;REPROCESS=5
    Persistent Connectikon                     true
    Show Affected Rows                         Minimal
    Variant Representation                      String
    I have changed MTA to STA and also tried other admin user for service without luck.
    Any other hints?

  • Fatal error while converting doc to pdf

    While Adobe Acrobat 7.09 converted a rather simple (albeit long) Word 2003 document, I received the following fatal error message during the "Processing for Tag Information" stage of Acrobat PDFMaker.
    MS Visual C++ Debug Library
    Program: WINWORD.EXE
    Module:Reader For RTF.smrd
    File: <blank>
    Run-Time Check Failure #3 - The variable bNewRowExpectedBeforeFootNote is being used without being defined
    Abort Retry Ignore
    "Retry" dumps both applications.
    "Ignore" re-displays the error, each time with other variables; "iTableLeftBeforeFootNote",
    "iTableGapBeforeFootNote",
    "bFirstElementSentBeforeFootNote",
    "bRowHeightBeforeFootNote"
    and then continues processing, until this same cycle repeats itself several more times before the "Processing for Tag Information" finally completes.
    If the error is "IGNORED" enough, the conversion will complete. However I have not assessed the resulting pdf for usability.

    From what I understand of tagging, it just provides markup in the PDF to indicate where WORD put a paragraph or other format aspect. Thus the saving back to a WORD file is easier. Other than that, I do not think that tags are used for much, except possibly accessibility. I usually just print to the Adobe PDF printer for my needs, but I do not have links and such that are critical for transfer to the PDF. The thing to remember is that tags really bloat the PDF, and you just do not have the memory to deal with that. Unless tagging or other PDF Maker features are important to your need, then it may be best to turn them off. One thing I would suggest leaving in is the embedding of all fonts as subsets.
    Don't know that I helped much or even got it all correct, but maybe that is what you wanted to know. Bill

  • HP Photosmart c6280 fatal error 1606 during installation - Windows Vista 64 bit

    Hi!  I have a HP Photosmart c6280 printer that we have had for a few years.  We moved it and configured it for USB use instead of wired via ethernet through the network.  It worked great, but now my wife's project is done.  Now we have moved it back and wired it through the ehternet cable into the router. 
    It will print, but the HP solution center doesn't recognize it and it will not scan or do any othe functions.  I have done a complete UNINSTALL and reinstall multiple times. 
    After installation I checked the event viewer and every install fatal error is a "1606" and it states the following:
    Product: PS_AIO_02_ProductContext -- Error 1606. Could not access network location %APPDATA%\.
    I am ata complete loss as to how to resolve this......someone please help!
    Sheriff

    I would suggest doing a L3 uninstall on the printer. 
    1. Run disk cleanup on your computer- you can pass this step if you want
    2.Download and run the software and drivers below.=
    3. Once the download is done extracting, cancel the download.
    4.. Press the Windows key + R on the keyboard to bring up the run menu.
    5. Type %temp% in the run field and click OK.
    6. Look for, and open the folder starting with 7z (Example: 7zS2356)
    7. Open folder Util
    8. Open folder CCC
    9. Run the uninstall_ L4.bat 
    10. When the uninstall has completed restart the computer
    11. Run Disk cleanup from Accessories\ System Tools
    12. Download and install the latest version of Adobe flash player
    http://www.adobe.com/support/flashplayer/downloads.html
    13. Use this tool to clean the system and registry.  Note: This utility is not HP sponsored or approved.  HP and I are not responsible for damages or loss of data caused by the utility.  This step is optional.   You can skip it if you want.
    http://download.cnet.com/Advanced-SystemCare/3000-2086_4-10407614.html?part=dl-6271865&subj=dl&tag=b...
    14. Download and run the software and drivers below.=
    15. Run the download to reinstall the printer
    Note: Before making any changes to the registry make sure and make a backup copy.
    Back up registry:
    Type regedit in the search programs and files
    Click file, and then export
    Type file name, and chose save to location
    TAKE OUT ONLY THESE KEYS/FOLDERS!!!
     HKEY_CURRENT_USER > Printers>DevModes2 > * c6280 *
    - (delete printer name from window list; may need to check DevMode and Settings folders, too)
     HKEY_LOCAL_MACHINE > software> Hewlett Packard > Digital Imaging folder
    - (delete ENTIRE folder – IF computer NOT an HP, delete the ENTIRE HEWLETT PACKARD folder)
     HKEY_CURRENT_CONFIG> System > CurrentControlSet > Control > Print > Printers > * c6280 * - (delete any HP printer folders and the folders of any printer not in use)
    After this please restart the desktop, and then install the Download and run the software and drivers below. (select your OS)
    Just a note - if you participate in this thread I must inform you that these services are not endorsed by HP, and that HP is not responsible for any damage that may arise to your system by using these services. Please be aware that you do this at your own risk.

  • Fatal Error: The schema version of the database is from a newer version of WSUS

    Hello,
    CM2012 R2 RTM on Server2012 R2 RTM with SQL2012 SP1
    installed SQL, WSUS and then CM.
    When finished adding WSUS, there was a post installation message but I skipped it and continued to CM installation, as suggested on some blogs. WSUS in CM seems to be a real mystery... and there are multiple workarounds and suggestions. 
    Now my CM is ready to GO. Configured discovery, boundaries. All components appear green OK. My hand shaked when I click on post Deployment message related to WSUS in server manager. So I clicked it. And received: Post Deployment Failed. There is
    a path to log file. The error:
    Fatal Error: The schema version of the database is from a newer version of WSUS
    than currently installed.  You must either patch your WSUS server to at least
    that version or drop the database. WSUS was installed with SQL DB.
    What do you suggest?
    Thanks.
    Please see full log:
    2013-12-01 06:58:24  Postinstall started
    2013-12-01 06:58:24  Detected role services: Api, Database, UI, Services
    2013-12-01 06:58:24  Start: LoadSettingsFromXml
    2013-12-01 06:58:24  Start: GetConfigValue with filename=UpdateServices-Services.xml item=ContentLocal
    2013-12-01 06:58:24  Value is true
    2013-12-01 06:58:24  End: GetConfigValue
    2013-12-01 06:58:24  Start: GetConfigValue with filename=UpdateServices-Services.xml item=ContentDirectory
    2013-12-01 06:58:24  Value is D:\sources\wsus
    2013-12-01 06:58:24  End: GetConfigValue
    2013-12-01 06:58:24  Content directory is D:\sources\wsus
    2013-12-01 06:58:24  Start: GetConfigValue with filename=UpdateServices-DB.xml item=InstanceName
    2013-12-01 06:58:24  Value is confman
    2013-12-01 06:58:24  End: GetConfigValue
    2013-12-01 06:58:24  SQL instance name is confman
    2013-12-01 06:58:24  End: LoadSettingsFromXml
    Post install is starting
    2013-12-01 06:58:24  Start: Run
    2013-12-01 06:58:24  Fetching WsusAdministratorsSid from registry store
    2013-12-01 06:58:24  Value is S-1-5-21-1033354796-2088831985-1429053453-1003
    2013-12-01 06:58:24  Fetching WsusReportersSid from registry store
    2013-12-01 06:58:24  Value is S-1-5-21-1033354796-2088831985-1429053453-1004
    2013-12-01 06:58:25  Configuring content directory...
    2013-12-01 06:58:25  Configuring groups...
    2013-12-01 06:58:26  Starting group configuration for WSUS Administrators...
    2013-12-01 06:58:26  Found group in regsitry, attempting to use it...
    2013-12-01 06:58:28  Writing group to registry...
    2013-12-01 06:58:28  Finished group creation
    2013-12-01 06:58:28  Starting group configuration for WSUS Reporters...
    2013-12-01 06:58:28  Found group in regsitry, attempting to use it...
    2013-12-01 06:58:28  Writing group to registry...
    2013-12-01 06:58:28  Finished group creation
    2013-12-01 06:58:28  Configuring permissions...
    2013-12-01 06:58:28  Fetching content directory...
    2013-12-01 06:58:28  Fetching ContentDir from registry store
    2013-12-01 06:58:28  Value is D:\sources\wsus
    2013-12-01 06:58:28  Fetching group SIDs...
    2013-12-01 06:58:28  Fetching WsusAdministratorsSid from registry store
    2013-12-01 06:58:28  Value is S-1-5-21-1033354796-2088831985-1429053453-1003
    2013-12-01 06:58:28  Fetching WsusReportersSid from registry store
    2013-12-01 06:58:28  Value is S-1-5-21-1033354796-2088831985-1429053453-1004
    2013-12-01 06:58:28  Creating group principals...
    2013-12-01 06:58:28  Granting directory permissions...
    2013-12-01 06:58:28  Granting permissions on content directory...
    2013-12-01 06:58:29  Granting registry permissions...
    2013-12-01 06:58:29  Granting registry permissions...
    2013-12-01 06:58:29  Granting registry permissions...
    2013-12-01 06:58:29  Configuring shares...
    2013-12-01 06:58:29  Configuring network shares...
    2013-12-01 06:58:29  Fetching content directory...
    2013-12-01 06:58:29  Fetching ContentDir from registry store
    2013-12-01 06:58:29  Value is D:\sources\wsus
    2013-12-01 06:58:29  Fetching WSUS admin SID...
    2013-12-01 06:58:29  Fetching WsusAdministratorsSid from registry store
    2013-12-01 06:58:29  Value is S-1-5-21-1033354796-2088831985-1429053453-1003
    2013-12-01 06:58:29  Content directory is local, creating content shares...
    2013-12-01 06:58:29  Creating share "UpdateServicesPackages" with path "D:\sources\wsus\UpdateServicesPackages" and description "A network share to be used by client systems for collecting all software packages (usually applications)
    published on this WSUS system."
    2013-12-01 06:58:29  Deleting existing share...
    2013-12-01 06:58:29  Creating share...
    2013-12-01 06:58:29  Share successfully created
    2013-12-01 06:58:29  Creating share "WsusContent" with path "D:\sources\wsus\WsusContent" and description "A network share to be used by Local Publishing to place published content on this WSUS system."
    2013-12-01 06:58:29  Deleting existing share...
    2013-12-01 06:58:29  Creating share...
    2013-12-01 06:58:29  Share successfully created
    2013-12-01 06:58:29  Creating share "WSUSTemp" with path "C:\Program Files\Update Services\LogFiles\WSUSTemp" and description "A network share used by Local Publishing from a Remote WSUS Console Instance."
    2013-12-01 06:58:29  Deleting existing share...
    2013-12-01 06:58:29  Creating share...
    2013-12-01 06:58:29  Share successfully created
    2013-12-01 06:58:29  Finished creating content shares
    2013-12-01 06:58:29  Stopping service WSUSService
    2013-12-01 06:58:29  Stopping service W3SVC
    2013-12-01 06:58:32  Configuring database...
    2013-12-01 06:58:32  Configuring the database...
    2013-12-01 06:58:32  Establishing DB connection...
    2013-12-01 06:58:32  Checking to see if database exists...
    2013-12-01 06:58:32  Database exists
    2013-12-01 06:58:32  Switching database to single user mode...
    2013-12-01 06:58:32  Loading install type query...
    2013-12-01 06:58:32  DECLARE @currentDBVersion       int
    DECLARE @scriptMajorVersion     int = (9600)
    DECLARE @scriptMinorVersion     int = (16384)
    DECLARE @databaseMajorVersion   int
    DECLARE @databaseMinorVersion   int
    DECLARE @databaseBuildNumber    nvarchar(10)
    IF NOT EXISTS(SELECT * FROM sys.databases WHERE name='SUSDB')
    BEGIN
        SELECT 1
    END
    ELSE
    BEGIN
        SET @currentDBVersion = (SELECT SchemaVersion FROM SUSDB.dbo.tbSchemaVersion WHERE ComponentName = 'CoreDB')
        SET @databaseBuildNumber = (SELECT BuildNumber FROM SUSDB.dbo.tbSchemaVersion WHERE ComponentName = 'CoreDB')
        DECLARE @delimiterPosition INT = CHARINDEX('.', @databaseBuildNumber)
        IF (@delimiterPosition = 0)
        BEGIN
            RAISERROR('Invalid schema version number', 16, 1) with nowait
            return
        END
        SET @databaseMajorVersion = SUBSTRING(@databaseBuildNumber, 1, @delimiterPosition - 1)
        SET @databaseMinorVersion = SUBSTRING(@databaseBuildNumber, (@delimiterPosition + 1), (10 - @delimiterPosition))
        IF @currentDBVersion < 926
        BEGIN
            SELECT 3
        END
        ELSE
        BEGIN
            IF (@scriptMajorVersion > @databaseMajorVersion OR
               (@scriptMajorVersion = @databaseMajorVersion AND @scriptMinorVersion > @databaseMinorVersion))
            BEGIN
                SELECT 2
            END
            ELSE IF (@scriptMajorVersion = @databaseMajorVersion AND
                     @scriptMinorVersion = @databaseMinorVersion)
            BEGIN
                SELECT 0
            END
            ELSE
            BEGIN
                SELECT 4
            END
        END
    END
    2013-12-01 06:58:33  Install type is: UnsupportedFuture
    2013-12-01 06:58:33  DB is a higher version than the config scripts
    2013-12-01 06:58:33  Swtching DB to multi-user mode......
    2013-12-01 06:58:33  Finished setting multi-user mode
    2013-12-01 06:58:33  Microsoft.UpdateServices.Administration.CommandException: The schema version of the database is from a newer version of WSUS
    than currently installed.  You must either patch your WSUS server to at least
    that version or drop the database.
       at Microsoft.UpdateServices.Administration.ConfigureDB.CheckForUnsupportedVersion(DBInstallType installType, Boolean dbExists)
       at Microsoft.UpdateServices.Administration.ConfigureDB.ConnectToDB()
       at Microsoft.UpdateServices.Administration.ConfigureDB.Configure()
       at Microsoft.UpdateServices.Administration.PostInstall.Run()
       at Microsoft.UpdateServices.Administration.PostInstall.Execute(String[] arguments)
    Fatal Error: The schema version of the database is from a newer version of WSUS
    than currently installed.  You must either patch your WSUS server to at least
    that version or drop the database.
    "When you hit a wrong note it's the next note that makes it good or bad". Miles Davis

    Gerry,
    1. I uninstalled WSUS, removed DB, restarted. And reinstall WSUS again. This time MS Management Console of WSUS could not be started. I did it after WSUS was added following your blog pix.
    I checked c:\program files\update services, there were couple of missing directories by comparison what was in case when I installed WSUS after SQL but before CM: Tools, Shema, and another A.. something. I saw this issue on NOOB. And people copied these
    directories from previous installation.
    How we can explain this behavior on RTM version?
    Then I uninstalled it again. And give another try... Here I found another interesting thing. Please compare your slide number 5 from your link and attached one. You can see that on Add Roles and Features Wizard page are missing items. Some
    of them were found in next screen of my installation (I am using RTM server) but one API and Power shell  cmdlets were not listed on final screen before start install. May be those are note important...
    I reinstall again... and the MS Management Console fails again. Exactly the same thing that I saw during 2 weeks of trying to make works. Don't see what I can screw up here.
    What about missing directories after reinstalling WSUS. Is that normal? And in IIS there is no WSUS.
    I don't see here any difficult thing, just simple wizard... But it not works. Second CM server.
    What I do wrong here to create a failure of MMC. There is any blog with examples of RTM Server 2012 and CM RTM. All stuff is 2012. So kind of guesses and no precise thing to do...
    Sorry for my cry :). The only solution is to call MS and pay $250 for SUCH a trivial thing that not works.
    Any help? Please see pics. Can you confirm that you have the same or more directories in Update Services
    Thanks.
    API and Power Shell Cmdlets feature missed if compare with yours slides.
    "When you hit a wrong note it's the next note that makes it good or bad". Miles Davis

  • How to remove Fatal Error in Reports 3.0

    How to eliminate Fatal Error in the Reports,
    I created Formula column and in that i am writing query for
    retreiving values and storing that value in other variable which
    i declared in the formula columns PL/SQL and in that I didn't
    find any compilation errors but when i run the report i am
    getting the fatal error. Please give me the solution for that
    fatal error.

    Hi ,
    first goto the properties sheet of formula column.
    in the properties sheet
    increse the widht property by 200.
    still u have the same problem again increase by 100.
    repeat like that.
    at certain level u r error fixed.
    bye
    srini

  • Java.sql.SQLException: FATAL ERROR  for DB2

    Hi
    In my scenario IDOC-XI-DB2,
    When I am getting following error message in communication channel. I have checked all the field length, they are correctly displayed. Please let me know how to resolve the same.
    Message processing failed. Cause: com.sap.aii.af.ra.ms.api.RecoverableException: Error processing request in sax parser: Error when executing statement for table/stored proc. 'BI5FILMM.BSOMSAPP' (structure 'StatementInsert'): java.sql.SQLException: FATAL ERROR document format in structure 'StatementInsert': expected 'access' tag(s) not found
    Payload is as follows
    <?xml version="1.0" encoding="UTF-8" ?>
    - <I805_Abstr_CustOutlet_MT>
    - <StatementInsert>
    - <STATUS action="INSERT">
      <table>BI5FILMM.BSOMSAPP</table>
      <key OUTLET_NO="0001231229" OUTLET_RF="0002122756" OMFUNC="CRT" />
    - <access>
      <STATUS>N</STATUS>
      <IFCEDATE>1080701</IFCEDATE>
      <IFCETIME>160849</IFCETIME>
      <OUTLETTYPE>Y</OUTLETTYPE>
      <NAME>DREW SMITH AGAINXXXXXXXXXXXXXXXXXXX</NAME>
      <STREET>E</STREET>
      <STATE>NSW</STATE>
      <POST_CODE>2000</POST_CODE>
      <PHONE_NO>567999</PHONE_NO>
      <ALTPHONE>11111</ALTPHONE>
      <FAX_NO>111</FAX_NO>
      <CNTCT_PERS>Constant</CNTCT_PERS>
      <ALTNAME>Constant</ALTNAME>
      <EMAIL1>Drew_downunder</EMAIL1>
      <EMAIL2>DREW_DOWNUNDER</EMAIL2>
      <SFE_CODE>G</SFE_CODE>
      <BILL_TO>0001231229</BILL_TO>
      <SUPP_DATE>080801</SUPP_DATE>
      </access>
      </STATUS>
      </StatementInsert>
    - <StatementProce>
    - <STATUS action="EXECUTE">
      <table>CC5PTF.BSOMPSAP</table>
      <Para1 isInput="true" type="CHAR">BI5FILMM</Para1>
      <Para2 isInput="true" type="CHAR">BMIJOBD</Para2>
      </STATUS>
      </StatementProce>
      </I805_Abstr_CustOutlet_MT>

    Hi Ria,
    In your input try to make the access tag in capitals(ACCESS) and try. I am not sure though. I think its case sensitive. Just try and let me know. Also your second action="EXECUTE" does not has any access parameters. Refer to this blog:
    JDBC Receiver Adapter -- Synchronous Select – Step by Step
    It might be useful.
    Regards,
    Sanjeev.

  • Error: Fatal error in function BldAlter on call to function GetOldRecDefn.

    At step "Generating the Updated PeopleTools Script" to generate "PPLTLS84CURTables.sql", more than 2270 errors occured:
    Example Error 1:
    System Error : File: E:\pt85403d-retail\peopletools\src\psbld\bldalter.cppSQL error. Stmt #: 4550  Error Position: 0  Return: 601 - [Microsoft][SQL Server Native Client 11.0][SQL Server]Invalid object name 'SYSCOLUMNS'.
    Failed SQL stmt: select c.name,c.colid,t.name,c.length,c.prec,c.scale,c.isnullable         from SYSCOLUMNS c, SYSOBJECTS o, SYSTYPES t        where c.id = o.id        and c.usertype = t.usertype        and o.type = 'U'        and o.name = :1        order by c.colid
    After changing table/view names from upper case to lower case. the query works.
    Example Error 2:
    Error: Fatal error in function BldAlter on call to function GetOldRecDefn.  Return code = 1. (76,6)
    Error: MENU_LANG_TMP - SQL Error. Error Position: 0  Return: 601 - [Microsoft][SQL Server Native Client 11.0][SQL Server]Invalid object name 'SYSOBJECTS'.
    SELECT NAME FROM SYSOBJECTS WHERE TYPE = 'TR' AND NAME = :1
    Error: PSMSFTMPCOM - SQL Error. Error Position: 0  Return: 601 - [Microsoft][SQL Server Native Client 11.0][SQL Server]Invalid object name 'SYSOBJECTS'.
    SQL Build process ended on 11/7/2014 at 10:39:42 AM.
    2698 records processed, 2274 errors, 0 warnings.
    SQL Build script for all processes written to file E:/temp/CAOutput/softwareupdatePeopleTools_Only_Upgrade{HR90UPG}/PPLTLS84CURTables.sql.
    SQL Build log file written to E:/temp/CAOutput/softwareupdatePeopleTools_Only_Upgrade{HR90UPG}/BuildPPLTLS84CURTables.log.
    Thanks for any suggestions!
    Dongmei

    Passed the above error by changing object owner from ACCESSID to dbo. Now on the same task "Generating the Updated PeopleTools Scripts", there are 516 errors, sample error messages:
    Error: PS_APP_DES_OBJ_CST - Alter failed due to an unknown column type (NVARCHAR) found for field PSOWNER. (76,22)
    Error: Fatal error in function BldAlter on call to function GetOldRecDefn.  Return code = 1. (76,6)
    Error: PS_APP_DES_OBJ_LNG - Alter failed due to an unknown column type (NVARCHAR) found for field PSOWNER. (76,22)
    Error: Fatal error in function BldAlter on call to function GetOldRecDefn.  Return code = 1. (76,6)
    Error: PS_APP_DES_OBJECTS - Alter failed due to an unknown column type (NVARCHAR) found for field PSOWNER. (76,22)
    Error: Fatal error in function BldAlter on call to function GetOldRecDefn.  Return code = 1. (76,6)
    Warning: MCF_IM_DEMO_REC.MCF_IMUSERID - Default record.field MCF_IM_DEMO_REC.USER_OPRID has no rows, field type default used. (76,66)
    Error: PS_PRCSDEFN - Alter failed due to an unknown column type (NVARCHAR) found for field PRCSTYPE. (76,22)
    Appreciate any help!!
    Dongmei

  • JDBC : Fatal Error: Column Doesn't exist error .

    Hello all,
       I am getting following error in a JDBC adapter monitoring :
    Error when executing statement for table/stored proc. 'Purchase_Order' (structure 'STATEMENTNAME'): java.sql.SQLException: FATAL ERROR: Column 'Test' does not exist in table 'Purchase_Order'
    But the thing is that, the table do have the 'Test' column and I can update this table using Update SQL statement. There are 8 columns in this table. XI can update all 7 columns except this 'Test' column.
    Any idea why? I evern rename this column to something else and no luck.
    Regards,
    N.S

    Swamy,
    Why dont you try to execute the SQL statement or the Stored procedure at the Database level? If it executes there then you can figure out in XI. If it dont execute there then you have to check the syntax for the query or the stored procedure.
    Try this out once.......
    ---Satish

Maybe you are looking for

  • How To Send a URL

    I am making an application the needs to go to a URL I do not need to see the URL but i need to be able to have a connection made to it to send data to the server like a GET method Example.... URL is http://www.myserver.com?name=hello Can someone help

  • I can't open Roxio Easy CD Creator Cds on my Macbook

    I created some CD files using Roxio Easy Cd Creator version 6 on a pc. When I close the disks so that they can be read on any CD-Rom, I still can't open them on my mac. I get three separate files, on and .exe file, the other a .zl file and third is a

  • BAM cannot connect to WEBLOGIC

    I have this setup in my EMS : WeblogicJMS View|Edit|Copy|Delete|Create|Start|Stop|Test|Refresh Name: WeblogicJMS Owner: fmwadmin Created: 7/29/08 3:00:57 PM Last modified: 7/30/08 6:34:52 PM Status: Stopped Initial Context Factory: weblogic.jni.WLIni

  • Aligning a Dot Matrix Printer

    Hi. Is there a function in Oracle Reports to allow the application to send a command to a Dot matrix printer after one job is done to re-align itself for the next print job? Thanks for your help in advance.

  • How do I secure a Mac Mini?

    I'm going to college in the Fall and want to buy a Mac Mini, but I'm concerned about security.  What are my options?