User defined Variable with multiple value

Hi Experts,
customer requirement is the following:
Build a layout in which to have in Lead Column the cost center characteristics, but not all cost center in master data but only those chosen by user with manual input. To achieve this goal i have created a variable of type characteristics (associatd to cost center CH) with replacement type "user defined values", then i have put this var in planning level. I have created a layout with Cost Center in Lead Column and set "all possible ch combination" in additional setting.
Thanks to the varable created, the user can enter Cost Center value, but the problem is that he cannot select more than one single cost center value, for example:
User want to see in layout CosCen1 and CosCen4, by now he can set variable in order to see the entire range from CosCen1 to CosCen4 (included all intermediate Cost Center) or to see only one between those 2 Cost Center, but it's not possible (or better i don't know how to..) to select both cost center and display the layout with ONLY those 2 Cost Center in Lead Column (CosCen1 and CosCen4).
In other word, is it possible to set a variable with more than one single value without using range from-to?
If not, does exist an alternative?
Thanks in advance.
Fabio

Hi Fabio,
It works as follows.
let's say you have 3 multiple single lines for your cost center variable.
once you are in the folder, select any single value & the layout is ready for planning with the corresponding cost center.
now, select the "Cost center variable row" in the header of the folder within section "Name of Variable" & click on "Trash Can" icon to "Delete Selection" of variable.
this basically deletes all the entered selections (3 entries) & displays for all.
It works this way, because we don't have "resriction of values required by user".
if am not wrong & correct me if am wrong,
overall, this is nothing but equal to "planning level not restricted with any variable".
I just tested this & the flaw in this is that, it is not only displaying for all the initially entered 3 lines but it displays for each & every cost center irrespective of the variable selections.
hope it is clear.

Similar Messages

  • A variable with multiple values. Is it possible?

    Normally, when we need a variable with multiple values we just write them while creating the variable or, if they depend on some other variable selected by the user a variable of type exit is used.
    However, this time we would like my user to select <b>a few</b> variable values <b>at a time</b>, i.e years 2005,2006 and 2007. He can change his mind and then select 2007 and 2008. I don't want the user to be forced to select ONLY ONE value. They need to select several values at the same time.
    Ideally, I don't want to use a range with values from 2 variables to do that.
    Thanks,
    Alberto Sabate
    Message was edited by: Alberto Sabate

    Hello Alberto,
    When restricting variables to multiple values you need to use a range. The variable restriction in BPS supports two operators EQ - equals and BT - between.
    In your example below however you could use a user exit to support this. The years you have typed in below are sequential and therefore would fit into a range.
    Cheers,
    Scott

  • Report script - using substitution variable with multiple values

    Hi All,
    Substitution variable with multiple values is not working correctly with Report scripts. Can you please let me know what is the syntax to assign multiple values to a sub variable using maxl:
    alter database samp.samp set variable 'ExtractQuarter' 'Q1,Q2,Q3,Q4';
    alter database Samp.Samp set variable 'ExtractQuarter' 'Q1:Q4';
    I tried both of the above but they are errored out with the below error:
    Error: 1001005 - Unknown Member [Q1:Q4] in Report.
    my requirement is different for both Actual and forecast data extract so i would like to make use of this variable to extract whole year data for Forecast and current quarter data for Actual with out duplicating the report scripts for both processes.
    Thanks,
    PRaveen

    Hi,
    Please refer following thread,
    range of months in report script?
    Hope it helps.
    Regards

  • Variable with multiple values.

    Hi All,
    Can anyone help me  to create a  variable with multiple values like it should accept two Buisness Area AU10,PH10 in Query.As well as how to use this variable in fox using VARV, VARI,and VARC.
    Thanx&Rgds,
    Indu

    Hi,
      You can write an exit for variable to retrieve two values.
    Usage of this variable in FOX..
    TOTALCOUNT= VARC(variable).
    COUNT = 1.
    DO .
    IF COUNT < TOTALCOUNT.
    varval = VARI( variable, COUNT ).
    COUNT = COUNT + 1.
    ENDIF.
    Hope this helps.
    Regards,
    Bindu

  • Web Forms using substitution variables with multiple values

    Hi,
    I am trying to select a substitution variable in a webform (Hyperion Planning 11.1.1.3) with multiple values in EAS, but is not working does somebody knows if this an expected behaviour.
    I allready try ex.
    &Months = "Jan","Feb", "Mar"
    &Months = Jan, Feb, Mar
    &Months = Jan:Mar
    Please let me know something, since as far as I recall in previous versions of Hyperion Planning this was possible.
    Kind Regards

    We experienced the same issue, our requirement was that for the first half of the year the substitution variable was = Oct and for the second part of the year Jan:Dec. We were lucky that for the second scenario we had a Total Year member as well (that at the bottom level is Jan:Dec). So on web form we picked Level0 descendants of the substitution variable. That worked fine but not the range.

  • SQLPLUS: define variable with multiple lines

    Hi All,
    I need define a varaible with multiple lines as following:
    define schema_name = 'aaa',
    'bbb',
    'ccc';
    select * from tb_test where sName in &schema_name;
    However, it seems SQLPLUS dose not like the way I define the variable. What I want to do is to select * from tb_test where sName in ('aaa', 'bbb', 'ccc'). I would like to use multiple lines in the define.  Any suggestion?
    Thanks,

    Hi,
    If the substitution variable contains special characters, such as spaces or single-quotes, then enclosed the whole value in double-quotes, like this:
    DEFINE  schema_list = "'aaa', 'bbb', 'ccc'"
    If you really need linefeeds in the value, then you might have to use COLUMN ... NEW_VALUE (or OLD_VALUE) to set the value.  For example:
    COLUMN schema_list_col NEW_VALUE schema_list
    SELECT  '''aaa'', ' || CHR (10)
         || '''bbb'', ' || CHR (10)
         || '''ccc'''     AS schema_list_col
    FROM    dual;

  • User entry variable with exclude values

    Hello All,
    I created a  user entry/ default value variable, which allows multiple single values and is optional entry. And I also got to exclude few values from this infoobject as well as have a variable.  When I select and exclude my value from selsction and run the report, I get a system error and the varibale is converted to mandatory entry. The detail error message is displayed below.  Any useful input will be awarded
    Diagnosis
    Variable &V1& is used in the query in such a way, that an optional entry is not possible.
    For example, you might be using an "Exclude", or the variable might be connected using OR to additional selections for &V2& in the global filter, but is still displayed in the columns selections.
    It is also not possible to use an optional parameter variable to fill an interval selection in either the from-field or the to-field.
    System response
    Procedure
    If you are able to accept the mandatory entry, you need not do anything. Otherwise you must work with several variables in the query. You can use an optional interval variable to do this.
    Procedure for System Administration

    Hello ,
    I did try creating a variable with the foll details:
    Variable Type : User Entry / Default Value
    Variable Represents : Multiple Single values
    Variable entry optional
    When I run the query it converts my variable to mandotary entry.  but I want to have optional user entry variable.
    Any help will be awarded

  • Using substitution variable with multiple values in Maxl Command

    Hi All,
    Is there any option to use multiple values in 1 substitution variable and use them in a Maxl command.
    alter database $app_name.$db_name clear data in region '{CrossJoin(CrossJoin(CrossJoin({StrTOMbr(&Months)},{XXX, YYY}),{StrTOMbr(&CURYR)}), {ZZZ})}'physical;
    In the above case
    Maxl is not working if I have multiple months in &Months Substitution variable.
    Let me know if there is an alternate option to implement this.
    Thanks
    Sathish

    What is the value of &Months?
    If you put that exact value into the code, does it work?
    Regards,
    Cameron Lackpour

  • Exit variable with multiple values or with ranges

    Dear Experts,
    I have a date exit variable used in a planning level. If the variable has a single value, I am able to execute the planning function. But if the exit is populated with a range or multiple single values, I am unable to execute the planning function. I get this message 'Variable "ZXPRDATE" is not restricted to a single value'.
    I should be able to read all records from the cube in date range of one week for repost. Please advice if this is possible.
    Thanks,
    Gnana

    Hi Mayank,
    Yes, I am using the same variable for repost function also.
    Let me explain in detial.
    Req: I have a planning level with product, effective date and count(keyfigure). I want all products that has a count keyfigure value for the last one week.
    If my effective date is a single value, I get all the list of products on that particular day. But, if my effective date has multiple dates or a date range, nothing is read from the data base.
    Please advice.
    Thanks,
    Gnana

  • COPA user-defined charact. w. own value maint. with existing check-table

    Dear Experts,
    I need to create a user-defined characteristic with own value maintenance with the pecularity that it needs to refer to the same check table as another user-defined characteristic with own value maintenance.
    Could anybody explain me how I can do that?
    Thanks in advance for your kind support.
    Best Regards,
    Eric

    Hi Eric,
    Generally when you are creating user defined charachteristic with own value maintainance check table is created by the system. So you requirement is not possible to achieve. As a workaounr you can create two char as you want and then copy the content of the first check table to the second one. This will have the same impact as what you have described.
    Best Regards,
    Abhisek Patnaik

  • Reposting error from 1 variable to another with multiple values

    Hi,
    we are on SEM 3.1B. I've 2 userExit variables (characteristic) VAR1 & VAR2 defined at plannin area.
    i am getting the following error, when am trying to use repost function from 1st variable values to 2nd variable values.
    "variable VAR2 is not suitable for setting field values".
    VAR1 & VAR2 both returns miltiple values but equal number of values always.
    let'z say,
    VAR1 returns values A1 B1.
    VAR2 returns values AA BB.
    Now, i need to use a repost function that reposts A1 to AA & B1 to BB.
    Is it possible? if not, can we even use functions like copy or formula on variables with multiple 'FROM' values to multiple 'TO' values?
    Appreciate your help / suggestions.

    Hi Marc,
    Thanks for ur reply. But, I am getting the following errors when checking the formula function.
    "Formula Error: Formula element VARC could not be recognized."
    similarly, "Formula Error: Formula element VARI could not be recognized."
    We are on BW 3.0B (SP: SAPKW30B17) and SEM 3.1B (SP: SAPKGS3B14). Are those fomrula elements exist in these versions? On what version have u tried?
    I even couldn't able to find any documentation on those formula elements VARC & VARI. Could you please let me know if there is any documentation?
    I'm trying to copy a KeyFigure value from one material to another mateiral. Both materials are calculated from variables of type user exit (with multiple values in each variable).
    PS: both variables have equal number of materials and should be copied one - one.
    Appreciate ur help.
    hari

  • 9144 with custom FPGA and SGL EtherCAT User-defined Variables?

    Hi,
    I currently have a small instrument driver (rs485) running on a 9144 chassis. The output values are communicated to the EtherCAT Master using FXP numbers. I would like to switch these FXP to SGL since I upgraded to LV 2012 SP1 with FPGA now supporting SGL numbers.
    Is this possible? I tried several times to create the SGL User-defined Variables in the project, but the date type is grayed out.
    Greetings from Munich,
    Götz
    Solved!
    Go to Solution.

    Unfortunately, SGL is not a supported data type for communication to/from a 9144. The available data types for user-defined I/O variables are:
    * Fixed Point
    * Signed Integers(Int8, Int16, Int32, Int64)
    * Unsigned Integers (UInt8, UInt16, UInt32, UInt64)
    * U32 Bit Field
    * Boolean
    More information regarding user-defined I/O variables can be found at:
    Programming EtherCAT I/O With FPGA Intelligence: Differences in the LabVIEW FPGA Programming API
    http://www.ni.com/white-paper/10618/en#toc4

  • Find and Replace with User Defined Variable

    I am in the process of converting some legacy help content to RoboHelp HTML 9 in order to give it some more features and customization for our clients. I have been taking advantage of User Defined Variables in order to customize the content. Up to this point I have been manually going through each topic and replacing each instance of a word ("statements" for example) with a user defined variable saying the same thing but with the possibility of being changed later should the customer want to. Though we only have about 200 topics, this is still relatively time-consuming and I would like to automate this as much as possible.
    Is there any way to find and replace content with a User Defined Variable?

    Hi there
    If you open the Script Explorer pod I believe one of the sample scripts is a "UDV Converter" script. Perhaps you could give that a try.
    Cheers... Rick
    Helpful and Handy Links
    RoboHelp Wish Form/Bug Reporting Form
    Begin learning RoboHelp HTML 7, 8 or 9 within the day!
    Adobe Certified RoboHelp HTML Training
    SorcerStone Blog
    RoboHelp eBooks

  • I want to set a variable with default value and can be changed by the user

    hi,
    i want to set a variable with default value and can be changed by the user, so i new a variable with setting : customer exit, single value, optional, ready for input.
    in my customer exit code, i set a default value, eg. 20070530
    when the variable screen popup, it display the default value 20070530, i changed it to 20070529, but it doesn't work , it still display the data in 20070530, how can i solve this problem? 
    your help is appreciated.

    Liu,
       As mentioned by Anil, you need to restrict your customerr Exit code to I_STEP = 1.
    or.
       <u>Open your Variable in change mode, in the Last Page os the Variable Maintenance you can provide default value. Note: you are doing same thing in Customer Exit. In your case no need of Customer Exit.</u>
    Nagesh Ganisetti.
    Assign points if it helps.

  • Can I get multiple User-defined variables in one slide?

    I have used the user defined variables in the past to collect identifiying information on quiz results, as well as for quiz certificate.  I would like to re-use the variables in a couple of areas.  in my project, one slide will prompt the User Name (variable I created), second will prompt for User ID (variable I created).  I would like a third screen that reads "Confirm your previous entries", and I want it to show the two variables.  I am only seeing the first one.  Is there a way to get them both to display?
    I would also like to re-use both in the quiz certificate at the end.  If I edit the certificate widget in Flash, will both variable display?
    This quiz reports to me via email (we have no LMS).
    Any suggestions?
    Cyndi Nagel

    Hi again
    Did you shrink the screen shot before uploading? You're right. It's barely legible.
    If the variables are being inserted in more than one caption, have you double checked the timing? Perhaps something is pausing the slide before one of the captions has a chance to appear.
    Cheers... Rick
    Helpful and Handy Links
    Captivate Wish Form/Bug Reporting Form
    Adobe Certified Captivate Training
    SorcerStone Blog
    Captivate eBooks

Maybe you are looking for

  • Windows Easy transfer , ERROR message when trying to copy settings to Win 8 PC

    I have a new hp-TouchSmart Envy 23. It has 2TB drive. I want to use Windows Easy Transfer to move all my settings and data from the Windows 7 machine to the new hp-TouchSmart (my older PC is hp desktop is model # m9177c and has Win 7 OS)  . I have us

  • Creating new buttons on different frame labels

    can someone tell me if im doing something wrong or assigning the as to the wrong frame? first off i have all my buttons on frame 2. im creating a real estate site and i have to have a couple links like HOME ABOUT BUYING SELLING CONTACT, the thing tho

  • Images look fine in Bridge, but way off when opened in Photoshop

    Not sure what I've done to my system, but am now having some color-management woes. I am using Photoshop and Bridge CS5.1, and for some reason, the color-management is not consistent between Bridge and PS... although it used to be until just recently

  • No Windows for conflict resolution in Isync

    Hello, After a synchro with iSync, I see conflicts. When I try to resolve them. The resolve conflit app is launched but i have no windows. To be clear I have not the possibility to resolve conflict because the windows apps do not appears. But I have

  • Export frame number