Vlan mismatch error
All,
I have investigated and made sure the speed/duplex have been changed between both devices attached to int-faces.
here is my error.
02-ext-liv FastEthernet0/20 (40).
Feb 20 16:22:18.711 PST: %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered on FastEthernet0/xx
2900 series switch.
What other approach shall I take to pin point the issue since this is only informational on the error log.
-fz
Thanks in advance!
Hi,
The 'error' message is simply because you have used different VLAN IDs on the access ports at either end. CDP discovers this and logs a warning. The message is pretty harmless in itself.
There are a couple of options to get rid of it:
- configure the access port to be the same VLAN on the two switches at either end of the link
--- OR ----
- enable CDP version 1 on your switches. YOu can do this using: 'no cdp advertise-v2'.
The latter option is simpler and you don't really lose much...
Hope that helps - pls rate the post if it does.
Paresh
Similar Messages
-
Native vlan mismatch error msg from cdp
get this message from my 6509 connects to 3550. but no trunking is set between them. my other ports also have the same settings, with no err msg but have a native vlan unknown status... why???
this 6509 is not set by me.. :(I do not have enough information from you to say if it is a bug. Past output of
sh ver
sh cdp neigh detail
sh int trunk
sh run int gigx/y or sh run int fas x/y -
Hello! I have a network in with a i have a switch stack configured for voice and data. Particularly, both are configured to pass over the same port.
I want to add a temporary switch (different model) to the network and configure it the same way. In particular, I want to see that I can set up the voice/data VLAN's on this new switch and test to confirm all is working. I need an uplink though back to the original switches so that this new switch can get a proper connection.
When I connect the new switch in, I can't seem to get an IP and the CLI keeps showing a "Native VLAN mismatch error" and shows the hostname of the original switch.
So my questions are:
How can I add this temporary switch to the existing switch to get a connection, not as another stacked switch?
How can I configure the voice/data VLAN's on the switch so as to be able to test the voice/data traffic over the same port?Hi! Yes I did change the native vlan for that particular port on "Sw2" (New switch) to match "Sw1" (existing switch). The Sw2 port shows native vlan inactive though.
Below is an output from them on that port.
(SW1)
Name: Gi3/0/5
Switchport: Enabled
Administrative Mode: trunk
Operational Mode: trunk
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: dot1q
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 100 (VLAN0100)
Administrative Native VLAN tagging: enabled
Voice VLAN: 10 (VLAN0010)
Administrative private-vlan host-association: none
Administrative private-vlan mapping: none
Administrative private-vlan trunk native VLAN: none
Administrative private-vlan trunk Native VLAN tagging: enabled
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk private VLANs: none
Operational private-vlan: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001
Capture Mode Disabled
Capture VLANs Allowed: ALL
Protected: false
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Appliance trust: none
SW2
Name: Gi3/0/5
Switchport: Enabled
Administrative Mode: trunk
Operational Mode: trunk
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: dot1q
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 100 (Inactive)
Administrative Native VLAN tagging: enabled
Voice VLAN: 10 (Voice)
Administrative private-vlan host-association: none
Administrative private-vlan mapping: none
Administrative private-vlan trunk native VLAN: none
Administrative private-vlan trunk Native VLAN tagging: enabled
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk private VLANs: none
Operational private-vlan: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001
Capture Mode Disabled
Capture VLANs Allowed: ALL
Protected: false
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Appliance trust: none -
WLC 5508 duplex mismatch error
Hi I've got a WLC 5508 connected to a Catalyst 6000 switch. In the switch I've get a CDP duplex mismatch error every 30 min.
%CDP-4-DUPLEXMISMATCH:Full/half duplex mismatch detected on port 3/23
with the show port command I can see this:
Port Name Status Vlan Duplex Speed Type
3/23 WLC connected trunk full 1000 10/100/1000
With the show CDP neigh I see a duplex mismatch
C6K9> (enable) sh cdp neig 3/23 detail
Port (Our Port): 3/23
Holdtime: 142 sec
Capabilities: HOST
Version:
Manufacturer's Name: Cisco Systems Inc. Product Name: Cisco Controller Product Version: 7.0.116.0 RTOS Version: Erro Bootloader Version: 1.0.1 Build Type: DATA + WPS
Platform: AIR-CT5508-K9
Port-ID (Port on Neighbors's Device): GigabitEthernet0/0/1
VTP Management Domain: unknown
Native VLAN: unknown
Duplex: half (Mismatch)
But in the WLC console there is not half duplex
(WLC5508) show>port 1
STP Admin Physical Physical Link Link
Pr Type Stat Mode Mode Status Status Trap POE SFPType
1 Normal Forw Enable Auto 1000 Full Up Enable N/A 1000BaseTX
I don't have errors in the port counters
How I can resolve this duplex mismatch?Try upgrading the firmware of the WLC to 7.0.230.0.
-
I am getting the following message in my logs on SF300-8
"%CDP-W-NATIVE_VLAN_MISMATCH: Native VLAN mismatch detected on interface fa1."
What is causing the error, see VLAN setup below:Hi,
Yes, in this case you can change the native vlan on the that switch with the command (config-if)#switchport trunk native vlan #, there is no need to reboot the switch in order for the change to take effect.
Regards, -
How one Switch identify the Native vlan mismatch
Dear All,
I am using two cisco L2 switches. Both are connected by a trunk link. Unfortunately I configured different native vlan between two switches. Suddenly I got an error that native vlan mismatch. When I changed the configuration Now it's working fine. My question is that how one switch identify that native vlan mismatch(either by Bpdu, cdp or packet). Please mention which of the following used by switch to identify native Vlan mismatch.
Regards,
SanjibSanjib, Karsten,
It's CDP.
Yes, and STP as well if you run a trunk between the two switches. PVST+ and RPVST+ BPDUs have a TLV in their trailer that carries the VLAN number for which the BPDU was originated. If the BPDU is received in a different VLAN (caused by a native VLAN mismatch), the receiving switch will be able to detect it.
Wireshark 1.12.x will be capable of displaying this TLV field in captured PVST+ and RPVST+ BPDUs. Until 1.12.x is released, you may want to try daily builds from:
http://www.wireshark.org/download/automated/
They already incorporate the enhancement.
Best regards,
Peter -
Type Mismatch error while saving a BPC Report using eTools
Hi,
Iam getting a 'type mismatch' error when trying to save a BPC Excel workbook using eTools>Save Dynamic Template >Company>eExcel. I am saving it as an .xlsx file.
Can anyone please help out and let me know why I am getting this error.
Thanks
ArvindHi,
You need to save the file as .xls extension. -
Hi,
I'm having a problem in calling the Java Applet's Function from Visual Basic. First, I'm getting the handle of the Java Applet and components of it using "Document.Applets(n)" which is a HTML function. I'm calling this function from Visual Basic. My code is something like this...
' // Web1 is IE Browser in my Form.
Dim Ap,Comp
Dim Bol as Boolean
Bol = true
Ap = Web1.Document.Applets(0).getWindow() ' \\ Gets the Parent Window.
Ap.setTitle("My Java Applet") ' \\ Sets the Title of the window.
msgbox Ap.getVisibility() ' \\ This will return a Java boolean ( true or false )
Ap.setVisibility(Bol) ' \\ Function Syntax is : void setVisibility(boolean b)
Here in my code , i'm able to call any function that which accepts Integer or String but not boolean. So, i m facing problem with Ap.setVisibility() function. It gives me a "Type mismatch error" while executing it. Can you please tell me a way to do this from Visual Basic !
I'm using Visual Basic 6.0, Windows 2000 , J2SDK 1.4.2_05.
Please help me Friends.
Thanks and Regards,
Srinivas Annam.Hi
I am not sure about this solution. try this
Declare a variable as variant and store the boolean value in that variable and then use in ur method.
Post ur reply in this forum.
bye for now
sat -
Characterset mismatch error while export
Hi,
I am getting characterset mismatch error while exporting a schema.
select * from nls_database_parameters where parameter in('NLS_LANGUAGE','NLS_TERRITORY','NLS_CHARACTERSET')
PARAMETER
VALUE
NLS_LANGUAGE
AMERICAN
NLS_TERRITORY
AMERICA
NLS_CHARACTERSET
AL32UTF8
i have set nls_lang on OS level
NLS_LANG = AMERICAN_AMERICA.AL32UTF8
C:\oracle\ora92\bin>
C:\oracle\ora92\bin>
C:\oracle\ora92\bin>exp hrtemp_v6/hrtemp_v6@testdb file=c:\hrtemp_v6 statistics=
none
Export: Release 9.2.0.1.0 - Production on Mon May 14 11:55:58 2007
Copyright (c) 1982, 2002, Oracle Corporation. All rights reserved.
Connected to: Oracle9i Enterprise Edition Release 9.2.0.1.0 - Production
With the Partitioning, OLAP and Oracle Data Mining options
JServer Release 9.2.0.1.0 - Production
Export done in WE8ISO8859P1 character set and AL16UTF16 NCHAR character set
server uses AL32UTF8 character set (possible charset conversion)
About to export specified users ...
. exporting pre-schema procedural objects and actions
. exporting foreign function library names for user HRTEMP_V6
. exporting PUBLIC type synonyms
EXP-00008: ORACLE error 6552 encountered
ORA-06552: PL/SQL: Compilation unit analysis terminated
ORA-06553: PLS-553: character set name is not recognized
EXP-00000: Export terminated unsuccessfully
please suggest , whats wrong here
thanks & regardsi have set nls_lang on OS level
NLS_LANG = AMERICAN_AMERICA.AL32UTF8How and where?
C:\oracle\ora92\bin>At this command prompt, what do you get back from "set nls"
You can use
c:\> set nls_lang=.al32utf8
...right before you issue exp command. -
Hi,
I am facing issues like Type Mismatch while passing Array of interfaces from .NET to VBA and vice versa using VSTO technology.
My requirement is that ComInterfaceType needs to be InterfaceIsIDispatch.
My Interface definition is somewhat like this
[ComVisible(true)]
[InterfaceType(ComInterfaceType.InterfaceIsIDispatch)]
[Guid("AAF48FBC-52B6-4179-A8D2-944D7FBF264E")]
public interface IInterface1
[DispId(0)]
IInterface2[] GetObj();
[DispId(1)]
void SetObj(ref IInterface2[] obj);
[ComVisible(true)]
[InterfaceType(ComInterfaceType.InterfaceIsIDispatch)]
[Guid("CDC06E1D-FE8C-477E-97F1-604B73EF868F")]
public interface IInterface2
IF i am passing array of above interface (created in C#.Net) to VBA using GetObj API,i am getting type mismatch error in VBA while assigning the value to variable in VBA.Even assigning to variant type variable gives TypeMismatch.
Also while passing Array of interfaces from VBA using SetObj API,excel crashes and sometimes it says method doesn't exists.
Kindly provide some assistance regarding the same.
ThanksHi,
I am facing issues like Type Mismatch while passing Array of interfaces from .NET to VBA and vice versa using VSTO technology.
My requirement is that ComInterfaceType needs to be InterfaceIsIDispatch.
My Interface definition is somewhat like this
[ComVisible(true)]
[InterfaceType(ComInterfaceType.InterfaceIsIDispatch)]
[Guid("AAF48FBC-52B6-4179-A8D2-944D7FBF264E")]
public interface IInterface1
[DispId(0)]
IInterface2[] GetObj();
[DispId(1)]
void SetObj(ref IInterface2[] obj);
[ComVisible(true)]
[InterfaceType(ComInterfaceType.InterfaceIsIDispatch)]
[Guid("CDC06E1D-FE8C-477E-97F1-604B73EF868F")]
public interface IInterface2
IF i am passing array of above interface (created in C#.Net) to VBA using GetObj API,i am getting type mismatch error in VBA while assigning the value to variable in VBA.Even assigning to variant type variable gives TypeMismatch.
Also while passing Array of interfaces from VBA using SetObj API,excel crashes and sometimes it says method doesn't exists.
Kindly provide some assistance regarding the same.
Thanks -
How to solve the "type mismatch" error in jCOM early binding program?
I got a "type mismatch" error jCOM early binding program.
I use the VB as the jCOM client to access the EJB deployed on WLS7. While using the
object parameter like "java.lang.Integer" in EJB method call, I got that error message
and my VB client had to be stopped?
The same situation, the VB program work perfect when using the "int" as the parameter.
And I try to instance the "myTLB.JavaLangInteger" in my VB program, but how ? The
"New", "CreateObject" and "GetObject" all failure, I don't know what to do next ???Hi,
This problem Could happen when you referesh quality or test system.
Your delta setup for the related master and transaction data needs to be reinit.
What happens is when you init. the delta and subsequent delta is all maintained in your source system
please check Notes 852443,424848,834229
Hope this helps
Thanks
Teja
Message was edited by:
Teja badugu -
RowSet Column Type Mismatch Error
Hi,
I am using SOA 11g,
JDeveloper 11.1.1.3.0
BPEL, SOA 11g, DB2 Stored procedure,
In a BPEL service I am getting this error while invoking a DB2 Stored procedure with Strong XSD.
while running I am getting this error message. This error message while invoking DB2 stored procedure, both XSD are identical. Input to service & input to DB adapter.
java.lang.Exception: oracle.sysman.emSDK.webservices.wsdlapi.SoapTestException: Exception occured when binding was invoked. Exception occured during invocation of JCA binding: "JCA Binding execute of Reference operation 'dba' failed due to: RowSet Column Type Mismatch Error. The SQL type in the XSD (CHARACTER) does not match the SQL type in the RowSet (VARCHAR) for column LONGITEM of parameter RowSet. This procedure returns a RowSet which could in theory return any arbitrary result. However you chose at design time to generate a single strongly typed XSD describing this result set in all cases, based on a test execution of the stored procedure. This makes later XML transforms easier. You may have also edited the XSD directly. ". The invoked JCA adapter raised a resource exception. Please examine the above error message carefully to determine a resolution.
-CDHi CD,
maybe if your strong XSD contains db:type="CHAR", you could try to change it to "VARCHAR" instead.
HTH,
Steve -
Hi,
Iam getting a 'type mismatch' error when trying to save a BPC Excel Ecel workbook using eTools>Save Dynamic Template >Company>eExcel. I am saving it as an .xlsx file.
Can anyone please help out and let me know why I am getting this error.
Thanks
ArvindHi Arvind,
You need to save the template as .xls file. This will work properly. -
"Type mismatch" error in IE7/8 when using custom Actions Menu Image
Hi all,
in APEX 4.2: when using a custom image in the "Actions Menu Image" attribute in an interactive report, I get a "Type mismatch" error in IE7/8 when refreshing the report through PPR (filtering, sorting, paginating etc.). When I leave the "Actions Menu Image" field empty, everything works fine. The error doesn't seem to happen in IE9 (unless using compatibility mode), or in any non-IE browser.
I've been able to reproduce the issue in an application on apex.oracle.com:
http://apex.oracle.com/pls/apex/f?p=69347:1
Some debugging seems to indicate that the following line in widget.interactiveReport.js is the culprit:
lTemp.parentNode.replaceChild($x('apexir_WORKSHEET'), lTemp);Does anybody know if this is a known issue, or if there is some workaround?
Thanks,
TobiasHi,
Great solution Paul! It cost me a while before I found out the Action Menu Image was causing my interactive reports to stop refreshing in IE10 and not other browsers. Your solution works great, I've implemented it with a few minor adjustments:
- Put the css in report template (for some reason it didn't work in our own application stylesheet)
- replace 'url("/c/action_dropdown.gif")' with 'url("&APP_IMAGE_PREFIX./<path_to_image>")'
- place one dynamic action on page 0: after refresh of '#apexir_DATA_PANEL' , set event scope to "Dynamic".
- Let the Dynamic action also fire on page load.
- To make sure the dynamic action only works for pages with an interactive report add condition of type 'Exists' with expression:
select 1
from dual
where :APP_PAGE_ID in (select page_id
from apex_application_page_ir
where application_id = :APP_ID
Best regards,
Vincent Deelen -
Type mismatch error on my web page
I have a web page which calling the Javascript function like below:
function initoptymenu(row, col) {
var a = document.applets.Tree;
var m = a.menu();
if (m == null) return;
m.removeAll();
if (row.substr(0,1) == 'Q') {
m.Add("View Quote");
m.Add("Mark active");
else {
m.Add("Remove Opportunity");
m.Add("View/Edit Opportunity");
But, when the event happen to call this function on my web page, I got an type mismatch error. and the java console shows the Error as :
netscape.javascript.JSException: Failure to evaluate initoptymenu('Q1831',0)
Could anyone know what I need to do the make it work?
Thanks so much.
shuningIt is kinda hard to tell without seeing the rest of the script....
But your script function is expecting a string and a number as arguments, but sure that the caller (which you didn't post) is supplying the correct type of arguments.
V.V.
Maybe you are looking for
-
Hi, I am new For SRM MDM Regarding SRM MDM< installation i need some help 1) Is SRM MDM is inbuilt in the SRM 7.0 or we need to install seperately 2) In the installation manual it is given that we need to install SAP netviewer JAVA AS is this SRM JAV
-
Does the warranty cover the power adapter?
Lately my power adapter's light has been cutting in and out. Tonight I noticed it's frayed where the cable meets the input of the adapter. I'm wondering if the adapter is covered under Apple's warranty. I have Apple Care. Furthermore, the battery als
-
I am unable to copy and paste text from mozilla, clipboard error
Hi- It seems I am suddenly unable to copy and paste anything from mozilla into other text editors (word, wordpad, notepad). I am unable to use ctrl c or v, when trying to do Edit-copy or paste it seems as though nothing is "recognized" by Mozilla. I'
-
Sqlpackage.exe Azure export error started few days ago
I was using this for a couple of months and suddenly since few days, I can't do it anymore sqlpackage.exe /a:Export /ssn:xxxxxxx.database.windows.net /sdn:"xxx" /su:"xxx" /sp:"xxxxxxxxxxxxxx" /tf:"xxxxxx.bacpac" Connecting to database 'xxxxx' on serv
-
How to use previous TDMS data to simulate incoming data offline
This is not a cRIO question, but a LabVIEW question. I would like to not have to connect to my cRIO everytime I want to develop my real time code. How can take a previously saved TDMS data and have Labview read the values from this file one line at