What causes NIDSTermin​ateApp call in LabVIEW applicatio​n?

I have an application which periodically crashes with an exception c0000005 error. It is running on 2 different machines and has occurred on both machines (Windows 2000).
The Dr Watson log file shows very little information about the thread that crashes (it seems that it is pretty seriously trashed) but the back trace includes a call to NIDSTerminateApp. This is exported by nids.dll (the DataSocket library) so it leads me to think the problem may be there. However, I don't know if this is a response to an earlier problem (hence "terminate") or the cause of the problem.
I will include the log file below.
Ciao
Bill
Attachments:
HeatTreat_Crash-drwtsn32.log ‏53 KB

Bill,
The first thing I would try and get a handle on is whether the program is crashing on a common operation each time. Since the time elapsed between crashes varies so greatly, it doesn't really help in the process of narrowing things down. In this case, I would try and implement a log file for your program. Basically, place file write operations at various points in your program. They will serve as "checkpoints". When the program crashes, open the file and see what the last checkpoint that was passed. You will then be able to zoom in on the offending code if it is in fact the same piece of code causing the problem each run.
The drwtsn32.log file is an appended file, therefore the latest event is at the end of the file. Within Notepad, Scroll to
the bottom and search up for 'Application' . Somewhere beneath 'Application' is PID (process ID) this value is the process that was running when the Error was generated. Scroll down to check the list of processes and locate that number. In your file, this process is HeatTreatMain.e.exe.
Look for 'FAULT ->' and this is the place within the processes where the application error occurred. The new section shows the stack, however the function names are usually NOT correctly identified by the Dr. Watson.
In the vast majority of cases the drwtsn32.log file does not contain sufficient information in order to debug the failure. It only gives you an idea about the failure. It is the user.dmp file that might lead to a solution. The utility only creates the Dr. Watson log file (drwtsn32.log). You have to instruct the Dr. Watson to create the crash dump (user.dmp). Launch the utility by typing drwtsn32 in the Start»Run. You are going to get a new window similar to the one attached below.
Refer to the linked document for more information.
How Do I Debug a Non-Reproducible Crash?
Zvezdana S.
Attachments:
dr_watson.gif ‏10 KB

Similar Messages

  • What causes "low" or hard to hear calls?

    Well, this is a first post for landline question.
    First I would like to say, I have local calls with Verizon and long distance with Att&t. We have 2 providers because well.. it was set up like that almost 20 years and we decided just to leave it as is. I think there is only 2 major providers here in the state of RI, Cox Communications and Verizon.
    Comcast used to show ads here, but one year just disappared and I don't see Att advertising locally for internet service here either. I think Att became just a wireless company in this state.  
    The question I have is that both Incoming and outgoing calls have been a mixed bag over these past few years. The calls all do go through and we do have a dial tone. The problem is with the calls itself. Sometimes it would be to quiet so that we can't hear the other person on the other side or they can't hear us clearly.  We don't get much calls nor do we really make to many calls. It is just a number for friends and relatives to contact us. Sometimes hanging up and redialing fixes the problem.
    Does anyone know what causes a call to be to soft or quiet on one end? its not a huge problem and it happens only a few times I would say about 10% chance.  It hasn't become a problem yet, just becomes annoying when it does happen. Especially since we don't use the phone that much. 
    What we tried:
    1. Using different phones throughout the house during the problems and all phones seem to have the problem. Tried both cordless and wired connected phones quality remains bad so we tell them we will call them back or they should call again and that normally fixes the problem. There was one time I remember it didn't work but assumed since they were dialing from a cellphone it was just a cellphone problem on there end. 
    Also.. No one in the house hold owns a cellphone of any kind, so if anyone wonders why we still have a copper land line. It is because we found no use for cellphones yet.
    I would also like to add this house was made in the late 1930's, there is no NID box anywhere in the house. I have tried to look for it but it does not seem to exsist. It looks like it comes from the pole direclty to the house Which leads over to the electic panel where all the circuit breakers are. Some of the wiring looks bad so I don't even bother touching it. At one point the previous owners had a alarm system on the basement windows and it even has a fire alarm on the side of the house interestingly...
    For people who have experience with phone systems... Somewhere in the basement there is a ringer. When we get a phone call. The basement litterly starts rining like a phone is connected somewhere, even if no phone is connected to the basment. Does anyone know exactly what that box or what device causes rining? I probally should find a way to dial the home phone to figure out where it is coming from.  That thing is loud as heck if I can find it I would disconnect it or at least find a volume to turn down the ringer. 
    The basement is filled with a bunch of old wiring from an old alarm system that the previous owner had installed 20+ years ago. When we moved in we saw all this disconnected wire and all these wires rerouted. 

    Since we haven't heard back from you on the private board we escalated this to or have received a form submission, it appears assistance is no longer required. If you need any future help with your Verizon service, please make a post here on the forums so we can assist.
    Anthony_VZ
    **If someones post has helped you, please acknowledge their assistance by clicking the red thumbs up button to give them Kudos. If you are the original poster and any response gave you your answer, please mark the post that had the answer as the solution**
    Notice: Content posted by Verizon employees is meant to be informational and does not supersede or change the Verizon Forums User Guidelines or Terms or Service, or your Customer Agreement Terms and Conditions or plan

  • Private dll calling in Labview

    Hi everyone, (refinement of my question)
    I have two dlls. One contains public functions which I call from Labview. The functions in this dll call functions in the other (private) dll. However, how do I tell Labview where to find this private dll?
    I have tried installing the dll in the system path directory. I have also put the dll in various different places relevant to Labview (e.g. in the directory of the Labview executable file). However, none seem to work (.
    Is there an option in Labview where I can set paths to dlls?
    Any help will be gratefully received.
    Ciao,
    Matthew Banham (colleague of Francois)

    > I have two dlls. One contains public functions which I call from
    > Labview. The functions in this dll call functions in the other
    > (private) dll. However, how do I tell Labview where to find this
    > private dll?
    >
    > Is there an option in Labview where I can set paths to dlls?
    >
    The problem is that the system loader is what handles the dependent
    DLLs. Since LV knows about the primary DLL, we try multiple locations,
    the path in the dialog, next to the VI, in the LV search paths, and
    finally we ask the system to look in their places. LV doesn't know
    about the dependent DLL, and it is up to the system to find it. I'd
    recommend trying the system or windows folder again. That should be the
    right solution.
    An off the wall thought that might h
    elp would be to add a dependency
    directly into LV by making a DLL node that calls in the the "private"
    DLL. You don't actually have to call it, you can place it in a case
    structure with a constant set the other way. Anyway, this will cause LV
    to look for the DLL, and I think it might help if nothing else works.
    Greg McKaskle

  • ActiveX can't create object when VB Script called from Labview

    I have an interesting issue that I can't find a solution for. I am using the DIAdem Run Script.VI in Labview to call a script that opens an Outlook object and sends an email. When the script is called via LabView I get this error:
    However, when I manually run the script from the DIAdem script tab it works as expected with no errors.
    This is the code:
    'Begin email send function
    Dim oOutlookApp
    Dim oOutlookMail
    Dim cnByValue : cnByValue = 1
    Dim cnMailItem : cnMailItem = 0
    ' Get Outlook Application Object
    Set oOutlookApp = CreateObject("Outlook.Application")
    ' Create Mail Item
    Set oOutlookMail = oOutlookApp.CreateItem(cnMailItem)
    ' Set Mail Values
    With oOutlookMail
    .To = "[email protected]"
    .Subject = "Report: " & Data.Root.ActiveChannelGroup.Name & " for " & CurrDate
    .Body = "test automatic report emailing with VB Script."
    ' Add Attachement
    Call .Attachments.Add(strLocFileName, cnByValue, 1 )
    ' Send Mail
    Call .Send()
    End With
     (Original code includes Option Explicit and all variables are properly included/declared, I just took the snippet of what's causing the error).
    I have looked at the following threads for info already:
    http://forums.ni.com/t5/DIAdem/Some-errors-when-calling-LabVIEW-VIs-Interactively-from-DIAdem/td-p/2...
    http://forums.ni.com/t5/DIAdem/Active-X-component-cannot-create-object-Diadem-8-1/m-p/71212/highligh...
    -I tried running the script via Windows explorer (per Brad's suggestion) by itself without the DIAdem specific functions and it runs fine.
    http://forums.ni.com/t5/DIAdem/Error-while-runing-diadem-asynchronous-script-from-labview-on/m-p/111...
    -I am not running the scripts asynchronously
    Using Windows 7 (64bit), DIAdem 11.2 and LabView 7.1.1
    Thank you.

    Hey techerdone -
    I'm afraid I personally can't be of much help - I tested your code both from DIAdem and from LabVIEW and each worked without issues in both cases (Outlook closed, Outlook open).  I'm using DIAdem 2011 SP1, LabVIEW 2011, and Outlook 2007...
    Derrick S.
    Product Manager
    NI DIAdem
    National Instruments

  • What causes a slow mouse/cursor response on a fast machine?

    I have a system that has always displayed poor cursor redraw performance with certain adobe applications.   All rendering and other effects are fast, but basic mouse selections and button knobs are extremely unresponsive.   I have searched and searched and can not seem to find out what causes the mouse cursor speed issues.   Does anyone have any ideas as to why my mouse would slow for such basic Interface interactions?    Do I need to change my hardware, settings, displays, BIOS, etc?
    Any insight into what the mouse redraw/refresh is called in terms of computing would help me search for a solution.  And if you have a solution as to why my mouse cursor acts drunk and sluggish when interacting with the Adobe UI's in premiere and after effects and sometimes Photoshop I would greatly appreciate the help.
    Thank You.  I attached a screen shot of a very basic selection interaction that is dog slow.  The selection box redraws like there is a lag in some process associated with the square box overlay.
    Computer Specs
    Windows 7 64
    ASUS Z9PE-d8
    dual xeon
    64 gig ram
    quadro 5000 (driving two 30 inch dell monitors of different models  One DVI-D and the other Display Port)
    512 SSD main drive with windows Swap on 10k Raptor drive.
    *All have been updated and the issue remains for over a year and a half.
    Thank you so much.
    Cliff

    Your answer is in this part of your specs:
    > (driving two 30 inch dell monitors)
    It takes a long time to draw and redraw the pixels to the screen(s) with such large monitors.
    We can mitigate this by making some changes in how our UI is drawn to the screen, and such changes are a rather high priority for use to work on for the near future.

  • How can I call a LabVIEW executable from within another LabVIEW executable?

    I have a customer requirement for two LabVIEW executables. Based on their current setup, they need to run executable "A" or "B", both of which are under independent revision control. I have created a third "selection" executable that allows the operator to choose between one of the two, but I am receiving errors when I attempt to call a LabVIEW executable from within a LabVIEW executable using either the "System exec" VI or the "Run Application" VI. If I call a non-LabVIEW executable (such as Windows Explorer) everything works fine.

    > I have a customer requirement for two LabVIEW executables. Based on
    > their current setup, they need to run executable "A" or "B", both of
    > which are under independent revision control. I have created a third
    > "selection" executable that allows the operator to choose between one
    > of the two, but I am receiving errors when I attempt to call a LabVIEW
    > executable from within a LabVIEW executable using either the "System
    > exec" VI or the "Run Application" VI. If I call a non-LabVIEW
    > executable (such as Windows Explorer) everything works fine.
    As with the other poster, I suspect a path problem. You might try the
    path out in a shell window, and if it works, copy the complete absolute
    path to LV to see if that works. LV is basically passing the comma
    nd to
    the OS and doesn't even know what is in it, so you should be able to get
    it to work.
    The other poster commented on subpanels, which is a good suggestion, but
    without going to LV7, an EXE can have open more than one VI. You can
    use the VI Server and the Run method to fire up another top-level VI.
    The decision is whether you want both to be in unique processes.
    Greg McKaskle

  • What caused the iBook problem?

    I'm writing this for my wife, as she's unable to use her iBook for more than a few minutes before it locks up.
    I'm serving in the military overseas. My wife and I both use Apple products to chat, email, etc. When I spoke to her yesterday, she was frantic. Her iBook G4 apparently started making a strange noise and then stopped working altogether.
    I asked her what she had tried, and she explained that she spent over an hour on the phone with Apple support (I knew AppleCare might come in handy). The first support person she spoke with was, for lack of a better term, an idiot. This was confirmed by the third support person she spoke with. I'll explain later.
    The problem was that when she tapped her spacebar to wake up the computer, it didn't wake up completely. She got a grey screen, Apple logo, and that was it. I told her to be patient, that maybe it was reseting after an update (that was before I knew about the 10.4.6 update being available).
    Her computer auto-updates every Monday.
    I had her turn off the computer by holding down the power button. I then had her disconnect the power cord and remove the battery. I did this on a hunch (just in case the computer had a heat problem). She reconnected the power cord, pressed the power button, and it was back up and running - for about 5 minutes.
    Then the computer began making a not-so-funny noise again, and the spinning-beach-ball-of-death reared it's ugly head and wouldn't go away.
    The first support person had her use the install/boot disk that came with the computer. That was Panther. We're using Tiger. Bad idea.
    When the boot/install disk did not appear to be working, the first support person had her abort, and she was prompted with little phrases like "are you sure you want to quit, doing so now may damage your files" or something like that.
    He just had her keep clicking "OK" and eventually got tired of talking to her and told her the hard drive was bad and that she was SOL.
    The second support person was apparently too busy to troubleshoot any further and cut directly to "sorry, you're SOL".
    The third support person was a little more helpful in that he talked her through connecting the iBook to her G5 PowerPC iMac to attempt pulling the files over to the iMac (she had already resigned herself to the fact that the iBook hard drive was on it's last leg).
    She had asked the first support person about doing this and he said that if the files were corrupt on the iBook, they might corrupt the iMac, and that it was a bad idea. Not a very bright guy, considering the files would be copied to a folder, and wouldn't overwrite the iMac's system files.
    She started to transfer files and the iBook froze again. She repeated the steps I had her do earlier, managed to get a CD in the the drive, copied a few folder successfully to the CD, checked the CD to see if the files were there (success!) but then the iBook died before she could get the CD out. She's working on holding down the track pad button while rebooting to see if it'll spit out the CD as I type this.
    So, in addition to wanting to know how to resolve the problem, I'd like to know what caused it.
    What caused so many people to have alleged hard-drive problems within a day or two of each other?
    Is this Apple's first virus?
    Is this the work of a disgruntled Apple employee working in the updates department?
    Is this an evil Apple plot to force us to by MacBook Pro's that won't run Virtual PC?
    Will running the 10.4.6 hurt or help the situation?
    Why is there such inconsistency in Apple support and aren't they supposed to log their trouble-shooting steps performed thus far?
    My wife has been using Mac's for over 9 years. I've only been using them for 2 years. Up until now, I've had a lot of confidence in Apple to be a solid platform, even if not the fastest platform. This experience is not inspiring me to purchase another Apple computer.
    PowerBook G4 1.5Ghz 15   Mac OS X (10.4.6)   iBook G4 1.2Ghz 14, iSight, 23" HD Cinema Display, LaCie d2, iLap, nano, Airport Express

    Hi Robk64,
    You might want to look at...
    Knowledge Base Document #106214 on Troubleshooting Startup Issues
    Knowledge Base Document #58583 on How to use FireWire target disk mode
    Knowledge Base Document #106941 on Mac OS X: How to back up and restore your files
    Do you have the Tiger Install Disc?
    SOL?
    Her files probably won't fit on a CD; unless she has less then 700Mb.
    1."Is this Apple's first virus?"
    Negative
    2. "Is this the work of a disgruntled Apple employee working in the updates department?"
    No, I don't think so. Apple tries these out to try and avoid problems with their updates. Things happen that are not expected. They wouldn't put anything out unless they thought it was ready.
    3. "Is this an evil Apple plot to force us to by MacBook Pro's that won't run Virtual PC?"
    First off, look at #1 and think about what platform is notorious for virus problems (Mac has had not had any virus out breaks so far). There have been some "malware/macro" software that was meant to mess with Apple Computers. The most recent that was was over exaggerated was nothing special; MacWorld worked pretty hard to get it to effect their machine. As long as you know what you are downloading and where you are getting it from, you should have no problem.
    If you want VPC to work on a MacBook Pro; don't look to Apple. You should talk to Microsoft's Mac Department because Apple announced the Universal Binary switch a long time ago (with developer help) so that software companies could make the switch easier. If anyone is to blame; its Microsoft [they are busy working out their problems with Vista; I am guessing it will be awhile before you see VPC for MBP;) ]
    "Will running the 10.4.6 hurt or help the situation?"
    My opinion would to just reinstall Mac OS X after backing up the hard drive. That would probably fix your problem. Once OS X is installed; update the software.
    "Why is there such inconsistency in Apple support and aren't they supposed to log their trouble-shooting steps performed thus far"
    Once in a while Apple's personnel may make human errors. The second one you talked to may have seen her work-up and just reiterated what was said. They have resources we don't, but they can't really go beyond them because they can't see the product, and they are just call support. You may have to send it in.
    So in 9 years, you have had this one problem. We can't really tell you what is wrong with the computer because we can't see it ourselves; we can only give suggestions/ideas. Tell them her story, explaining her situation (military etc) and then see if they can help. She may want to bring it into her local Apple Store/Reseller. She can make a reservation on the website or at the store. She can get better feedback in person.
    Just some of my thoughts,
    Jon
    Mac Mini 1.42Ghz, iPod (All), Airport (Graphite & Express), G4 1.33Ghz iBook, G4 iMac 1Ghz, G3 500Mhz, iBook iMac 233Mhz, eMate, Power Mac 5400 LC, PowerBook 540c, Macintosh 128K, Apple //e, Apple //, and some more...  Mac OS X (10.4.5) Moto Razr, iLife '06, SmartDisk 160Gb, Apple BT Mouse, Sight..

  • What are the limitations of using labview 8.5.1 developers suite verses a real-time module in field point applications?

    What are the limitations of using labview 8.5.1 developers suite verses a real-time module in field point applications? Can an exe. be loaded onto a field point controller or does the controlling program have to reside on a PC for example?

    centerbolt is correct, you can't load a .exe or even run a program on the fieldPoint controller unless you have the Real Time module.  However, that does not mean you can't use your FieldPoint bank without the Real Time module. 
    From LabVIEW for windows you can make calls to the fieldpoint IO using the fieldpoint read/write functions. 
    This program runs on the PC not the FieldPoint controller.  If you loose network connection to the fieldpoint, your program will loose connection to the IO.  For many data logging applications this type of arrangement can work just fine.  However, if this is the only type of application you are ever going to run, then you may as well not buy the Real Time controller for your fieldpoint but the network controller only. 
    If your application requires more reliability, and/or greater determinism than can be achieved by running a program on windows, then you should use the LabVIEW Real Time module and develop a program that can run down on the FieldPoint controller independent of windows.
    Message Edited by StevenA on 07-22-2008 04:14 PM
    SteveA
    CLD
    FPGA/RT/PDA/TP/DSC
    Attachments:
    fp pallet.PNG ‏6 KB

  • What is the data throughput in labview. I want to use the parallel as acheap digital i/o to drive a stepper motor.

    I am trying to use the parallel port on a win xp machine to send data a@ up to a 3k rate. This is for the the purpose of driving a stepper motor. I have tried the port.out vi and placed this vi in a loop and it on a scope it looks like I am limited to a a 200hz rate. What am I doing wrong??? Can labview do this or is it too slow ???
    Thanks

    snook wrote:
    > what is the data throughput in labview. I want to use the parallel as
    > acheap digital i/o to drive a stepper motor.
    >
    > I am trying to use the parallel port on a win xp machine to send data
    > a@ up to a 3k rate. This is for the the purpose of driving a stepper
    > motor. I have tried the port.out vi and placed this vi in a loop and
    > it on a scope it looks like I am limited to a a 200hz rate. What am I
    > doing wrong??? Can labview do this or is it too slow ???
    Basically the way the Port I/O VIs are implemented they call through a
    device driver for each port access. This slows down the maximum port
    accesses to something like 1000 times per second depending on the speed
    of your CPU.
    There is a way to do it faster but that is a little more trick
    y. The
    idea is to use a device driver to enable particular port addresses to be
    accessed directly from the application level instead of always going
    through the kernel.
    I have written such a VI library and accompagning DLL and device driver
    and made it available on OpenG. It is not yet part of the standard
    binary distribution packets so you will have to get it from the CVS
    repository.
    Go to:
    http://cvs.sourceforge.net/viewcvs.py/opengtoolkit/portIO/built/portio/
    and download all the files in there including the ones in the
    subdirectory "ogportio.llb" and if you like "docs"
    If you want the nitty gritty technical details you can also look at
    http://cvs.sourceforge.net/viewcvs.py/*checkout*/opengtoolkit/portIO/c_source/Description.htm?rev=1.5
    On my 866 MHz Pentium mobile I can increase the number of port accesses
    in this way from 440 ms for 4000 read byte port accesses (100us ms per
    access) to 20 ms for the same number of read accesses (5 us per access).
    Rolf Kalbermatter
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • What are the advantages of using LabVIEW projects in TestStand, as apposed to just a path to a vi

    What are the advantages of using LabVIEW projects in TestStand, as apposed to just a path to a vi ?
    I am modifying an existing workspace for a new product, and it seems like more work to add the vi's into a LabVIEW project
    does it gain anything in the long run

    Hi Rusty,
    I wanted to quickly clarify on the integration between TestStand and LabVIEW Projects.
    As Jeff mentioned, some of the big benefits of using LabVIEW Projects is to organize code and to namespace them.
    For instance if you had a project called "Power Supply" that housed all your power supply code and had a VI in that called "Initialize", and another project called "Temperature Chamber" that also had a VI called "Initialize", both these VIs are namespaced by the project, so there is no longer confusion about which "Initialize" VI is being used.
    Now from a TestStand point of view, in prior version of TestStand, we lost some of this benefit because TestStand did not know about TestStand projects and called VIs simply as un-namespaced VIs. However, in TestStand 2010 (released last year, free eval available at ni.com/teststand), we added the ability to (optionally) call VIs within the context of their projects. This means that:
    VIs are now namespaced by their project, even when called from TestStand
    VIs can use project specific constructs like NI-DAQmx tasks and conditional compilation settings
    Note: When creating deployments, the VIs maintain their projects and namespacing, so this benefit holds true for deployments as well.
    Additionally, someone had mentioned looking into using lvlibs to namespace your VIs for deployment. Two comments:
    With TestStand 2010, this is no longer neccessary since the project itself namespaces the VIs
    You might also want to look into LabVIEW Packed Project Libraries, which combined several VIs into a single file. Think of it as a DLL specific to LabVIEW that is as easy to call as normal LabVIEW VIs. TestStand 2010 can call VIs that are exposed by PPLs. In addition, the deployment utility can automatically pack your VIs into PPLs for deployment.
    Hope this is helpful!
    Jervin Justin
    NI TestStand Product Manager

  • Inconsistency in structure u0093KOMPu0094 - what caused this?

    Hi All,
    We had a problem where all users experienced an ABAP Dump 'DDIC_TYPE_INCONSISTENCY' when running transaction codes such as FB50.
    To solve the problem SAP sent the following instructions:
    “The problem is due to Inconsistency in the Dictionary for the structure
    KOMP. If you go to TCode SE11 : KOMP > Display : Utilities > Runtime
    Object > Check -> Active runtime object for KOMP is inconsistent.
    To solve this error, please activate the structure KOMP manually by
    going to tcode SE11 : enter KOMP > Display : Structure – Activate”
    I have asked SAP what exactly caused this problem and they mentioned that a user had changed underlying structure of KOMP named KOMPAKE.
    Tcode SE11 is locked in Production to prevent stuff like this from happening and the only tcode the users ran before we experienced the first dump is KE30.
    SAP insists that KE30 could not have changed structure.  And the only changes made in production were transports imported 5 days before we experienced this problem.
    Would anyone have ideas on how I can determine what caused this problem?
    I would appreciate any help.
    Thanks,
    Kevin

    I looked at the version management for this structure KOMPAKE and the only entry I see is from the same user ID with a data/time stamp right before we experienced the first ABAP Dump, and the entry in the version managements starts like this:
    Version(s) in the development database:
      activ          X  640               
    I also noticed the same structure KOMPAKE changed in our QA environment by a user that was testing KE30 a day after we had this problem in Production.
    So maybe KOMPAKE was auto-generated by KE30 and somehow failed before it could complete, leaving it in an inactive state?
    But if that is the case why were there no problems before, can a structure be auto-generated if its already active?
    I also found this System log in SM21 where it shows the first ABAP Dump and the errors before it:
                                                                                    Time     Ty. Nr  Cl. User         Tcod MNo Text                                               
    19:06:14 DP                            Q0I Operating system call recv failed (error no. 232 )           
    19:06:14 DP                            Q04 Connection to user 10524 (User1 ), terminal 68 (PCComputer ) lost
    19:06:24 DIA 000 100 User1        KE30 R2C Terminal 00068 in status DISC                                
    19:06:24 DIA 000 100 User1        KE30 R68 Perform rollback                                             
    19:06:24 DIA 000 100 User1        KE30 R47 Delete session 001 after error 004                           
    19:06:24 DP                            Q0G Request (type DIA) cannot be processed                       
    19:07:26 DIA 000 000 SAPSYS            R68 Perform rollback                                             
    19:07:27 DIA 000 000 SAPSYS            AB0 Run-time error "DDIC_TYPE_INCONSISTENCY" occurred            
    19:07:27 DIA 000 000 SAPSYS            AB1 > Short dump "070327 190727 hsapecp1 SAPSYS " generated
    Message was edited by:
            Kevin Elias
    Message was edited by:
            Kevin Elias

  • What causes the ink cartridge's to bleed inside the printer?

    3310 a-in-1
    what causes the ink cartridges to bleed inside printer? have changed out all cartridges - problem still persists

    Hi @dkp529,
    Welcome to the HP Forums!
    I see that you are wondering what causes the ink cartridges to bleed inside the printer. I am happy to help!
    Most likely this is a mechanical issue with the printer itself, especially if you have changed out the cartridges and the problem is persisting. The best option at this point is to, please call our technical support at 800-474-6836 for an upgrade. If you live outside the US/Canada Region, please click the link below to get the support number for your region. Country-language selector. 
    Hope this answers your question, and have a good day!
    RnRMusicMan
    I work on behalf of HP
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    Click the “Kudos Thumbs Up" to say “Thanks” for helping!

  • Linux Cannot Create Shared Library to call from Labview. Anyone have any ideas?

    Hi there.  A while back i created a shared library (.dll) to call in labview which works great.  Lately i have been using Linux more and more and was hoping to recompile the shared library for use in Linux Labview.  My first go I am getting the following error #error "Unknown Linux platform"   from the platdefines.h.   Evidently it does not like my system.  Using QT creator on linux mint 64 bit.   Anyone have any ideas on how i can get this working?
    thanks so much!

    I have a few version questions: What version of Windows was this DLL orignally created in? What version of LabVIEW are you using? What version of Linux are you using? 
    I think you will also find this previous discussion forum thread useful: http://forums.ni.com/t5/LabVIEW/Calling-DLL-on-LabVIEW-for-Linux/td-p/58322

  • What causes cellular data usage to decrease if last reset has not changed? I reset every pay period cuz I do not have unlimited and was showing 125 mb sent/1.2g received. Now showing 98mb sent/980mb received. Last reset still shows same

        I reset my cellular data usage every month at the beginning of my billing period so that I can keep track of how much data I am using thru out the month. I do not have the unlimited data plan and have gone over a few times. It's usually the last couple days of my billing cycle and I am charged $10 for an extra gig which I barely use 10% of before my usage is restarted for new billing cycle. FYI, they do not carry the remainder of the unused gig that you purchase for $10 which I disagree with. But have accepted. Lol  Moving on.
        I have two questions. One possibly being answered by the other. 1. Is cellular data used when I sync to iTunes on my home computer to load songs onto my iPhone from my iTunes library(songs that already exist)? 2. What causes the cellular data usage readings in iPhone settings/general/usage/cellular usage to decrease if my last reset has not changed? It is close to end of my billing cycle and I have been keeping close eye. Earlier today it read around 180mb sent/1.2gb received. Now it reads 90mb sent/980 mb recieved. My last reset date reads the same as before. I don't know if my sync and music management had anything to do with the decrease but i didn't notice the decrease until after I had connected to iTunes and loaded music. I should also mention that a 700mb app automatically loaded itself to my phone during the sync process. Is cellular data used at all during any kind of sync /iPhone/iTunes management? Is the cellular data usage reading under iPhone settings a reliable source to keep track of monthly data usage? Guess turned out to be more than two questions but all related. Thanks in advance for any help you can offer me. It is information I find valuable. Sorry for the book long question.

    Is cellular data used at all during any kind of sync /iPhone/iTunes management? Is the cellular data usage reading under iPhone settings a reliable source to keep track of monthly data usage?
    1) No.
    2) It does provide an estimated usage, but it's not accurate. For accurate determination, you should check the remaining/used MBs from the carrier (most of the carriers provide this service for free).

  • What causes this message "Photoshop 13.1.2 for Creative Cloud Installation failed. Error Code: U44M1P7"?

    What causes error code: U44M1P7? I have rebooted my machine multiple times and continue to get the same results.

    Photoshop: Basic Troubleshooting steps to fix most issues
    ISSUE: Installation failed. Error Code: U44M1P7, U44M2P7, U44M1P6
    SOLUTION: Run the installer. Reinstall Photoshop CS6 to repair/replace the missing/modified file. Select Help>Updates… to run the updater again. http://helpx.adobe.com/creative-suite/kb/error-u44m1p7-installing-updates-ccm.html

Maybe you are looking for

  • RFC_CALL_TRANSACTION missing

    Hello, we had used to remote call  the transaction RFC_CALL_TRANSACTION 9SAP R/3 4.4C). Aftre upgrade to ECC 6.0 the transaction RFC_CALL_TRANSACTION does not exist. Which one can we use instead of it? Regards Zeno Edited by: zeno novak on Jun 18, 20

  • Mcafee site advisor not working with firefox 4.1, I would like to download an older version

    I downloaded the newest version of firefox 4.1 and now mcafee site advisor does not work. I would like to download an older version of firefox

  • Error in Nokia Suite

    Check the attached image, it says connect a USB cable to upgrade the software, but Nokia 112 does not have the option of USB cable, how do we connect a USB? lol , isn't it funny? if u do not support upgrade of Nokia 112 then why u have allowed the ne

  • Overview of SD

    Hello SAP Gurus, Can i have the documentation on overview of SAP Sales & Distribution? My email ID is <REMOVED> Thanks & Regards, Mohsin Message was edited by:         Yathish K

  • Stuck workflow after crash - SWPC is also not helping

    Hi Guys, There are some instances for a particular workflow background task which stucks and stops the workflow processing. This problem is not with all the instances. We have executed SWPC also but that is also not helping to solve our problem. Work