What is the main purpose of the synchronou​s disply in LV?

Anybody know what is really the synchronous display do. In the front panel, when we right click to the object,,
>>Advance
>>>Synchronous Display
When we can use this option??

If an indicator is set to have synchronous display the block diagram will always wait until the indicator value has been updated on the screen, otherwise everything will just continue even though the user interface has not "discovered" the new value yet....
here is an extract of NIs text on performance;
"In multithreaded systems, controls and indicators have a synchronous display pop-up item that controls whether or not updates can be deferred. In single-threaded execution, this item has no effect. However, if you turn this item on or off within VIs in the single-threaded version, those changes affect the way updates behave if you load those VIs into a multithreaded system.
By default, this item is off, which means that after the execution system passes data
to front panel controls and indicators, it can immediately continue execution. At some point thereafter, the user interface system notices that the control or indicator needs to be updated, and it redraws to show the new data. If the execution system attempts to update the control multiple times in rapid succession, you might not see some of the intervening updates.
In most applications, this significantly speeds up execution without affecting what the user sees. For example, you can update a Boolean value hundreds of times in a second, which is more updates than the human eye can discern. Asynchronous displays permit the execution system to spend more time executing VIs, with updates automatically reduced to a slower rate by the user interface thread.
If you want synchronous displays, you can turn the synchronous display on.
Note: Turn on synchronous display only when it is necessary to display every data value. Using synchronous display results in a large performance penalt
y on multithreaded systems."
MTO

Similar Messages

  • What is the main purpose of   VBA   in bex analyser

    what is the main purpose of   VBA   in bex analyser

    Hi,
    you can enhance standard BEx functionality with VBA Macros (Excel).
    Pls chk This link:
    http://help.sap.com/saphelp_nw04/helpdata/en/f1/0a55f9e09411d2acb90000e829fbfe/frameset.htm
    Regards
    CSM Reddy

  • What is the main Purpose of ADF tool...

    What is the main Purpose of ADF tool...

    Not sure what you mean, but take a look at:
    Oracle Application Development Framework - Wikipedia, the free encyclopedia
    Oracle Application Development Framework - Oracle ADF
    or, if you mean Oracle ADF Tools::
    http://www.oracle.com/technetwork/developer-tools/eclipse/overview/adf-315490.html
    Oracle ADF Tools

  • What is the main purpose of MEREP_EX_REPLIC  transaction code

    hi,
    i want know the main use of MEREP_EX_REPLIC, MEREP_MIG and
    MEREP_MON transaction codes.
    Regards,
    Anu

    Hi anusha,
    MEREP_EX_REPLIC-  (Execute Replicator) is used for  replicating SyncBO IDs.
    MEREP_MIG -    (Used for Migration) When u go for migration of a SyncBO using the SAP transport technology we use the Export and Import options.
    MEREP_MON-   (Mobile Monitor )The transaction MEREP_MON is a tool used to display inbound and outbound worklists of SyncBOs. Simply, transaction MEREP_MON allows you to see what is sent from the client to the MW and what happend when trying to send it to the Backend. May check there if you can see anything coming into the MW from the client. As well check what is the outcome (processing status) of these worklists.
    Do check the below link...Its worth.
    <a href="https://www.sdn.sap.comhttp://www.sdn.sap.comhttp://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/909d75c3-0801-0010-5f92-920a78c53daa">https://www.sdn.sap.comhttp://www.sdn.sap.comhttp://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/909d75c3-0801-0010-5f92-920a78c53daa</a>
    Similarly there are many other transactions...Check some of the below:
    MCD - MI:Process Mobile Component
    ME_WIZARD -ME:Registration and eneration
    MEREP_EX_REPLIC-Execute Replicator
    MEREP_LOG -Activity Log
    MEREP_MIG -Migration
    MEREP_MON- Mobile Monitor
    MEREP_PD - Profile Dialog
    MEREP_PURGE - Purge Tool
    MEREP_SBUILDER - SyncBO Builder
    MI_ALBACK - Back Up CCMS Alerts for MI
    MI_ALMON - Alert Monitor for MI Alerts
    MI_MCD -MI:Process Mobile Component
    MI_MSD -MI:Process Mobile Component
    S_ABA_72000157-Alert Customizing
    SMOMO - Mobile Engine
    Cheers,
    kumarR
    Message was edited by:
    KumarR
            kumarR

  • What is the main difference between BPEL and ESB

    Hi all,
    I am making use ESB in my application .Where the my client application calls ESB and inturn the ESB calls the BPEL process .
    I want to know the differences between BPEL and ESB,I came to know that ESB can do messaging and routing ,where my BPEL process can also do the same thing .
    I came to know form a vendor that ESB is used for connecting to multiple end points ,where as my BPEL process can also do this.
    SO what is main purpose of using ESB ?
    Cheers,
    Kalyan.
    Message was edited by:
    patti

    Hi,
    Look for the blog entry dated 1st october 2007.
    URL:
    http://abhishek-soablog.blogspot.com
    Cheers,
    Abhi...

  • What is the use of passing String[] args in main() method?

    what is the use of passing String[] args in main() method?
    Is there any specific use for this ?

    actually my sir asked me the same question & I gave
    the same reply as given by you........but he further
    asked what is the use of this also??
    ie accepting cmd line args at runtime??is there any
    specific purpose ??Apart from the one you just mentioned? No

  • What is the Purpose of Internal Sales Order in OM

    Hello All,
    Compared to normal Inter-Organization Transfer (Direct&In transit) in which business scenario, Internal Sales Order(ISO) Cycle would fit ? (In Manufacturing , Distribution etc.,)
    what is the (main) purpose of going for Internal Requisition (IR) - ISO ? & usage of Transfer Credit account in Inter-Org Transfer?
    Please share your implementation experience ?
    (if any)
    Thanks, Jay

    The most important 1st thought is ::
    Ques 1. Why ISO over Direct-Org transfer ?
    Ans ---- Direct-Org transfer is immediate 2-way txns where ... there is no concept of In-transit Inventory & its tracking(s).
    Source-Org Sub-inventory ~ issues out
    Dest'n-Org Sub-inventory ~ receives in
    which is very much like Sub-inventory transfers with the difference that its Inter-Org
    Ques 2. What is this concept of In-transit Inventory ~ Inter-Org transfer v/s ISO ?
    Ans ---- Yes both ( Inter-Org transfer or ISO ) have this concept of In-transit inventory & its tracking(s).
    Ques 3. Now the question is -- Why then ISO over Inter-Org transfer ? How ISO rules above Inter-Org transfer ?
    Ans ---- ISO is requisition based. Now using which we can have booked Sales-Order.
    Using their desirable shipping dates Planning, Replenishment & Reservations can be done. You just cannot do this Inter-Org transfer.
    Also the cost-price of Source-Org goes into the Dest'n-Org. Whereas in ISO you have both provision same cost price our using price-lists / modifiers ?
    No doubt !! ISO is very scalable route.
    Other technical reasons :: feel free to communicate ::
    Ajay Kuma
    c510-456-5322

  • The main purpose of table T778T - Infotypes per object type

    What is the  main purpose of T778T - Infotypes per object type.
    How does it differ from other subdialogs/tables in T778V?
    Points will be awarded.
    Thanks
    Olekan Babatonde

    T778T -you can change the attributes of an infotype
    You can make the following settings:
    You can change the infotype names.
    You can assign infotypes to standard object types or to customer- specific object types.
    You can define another time constraint for an infotype.
    T778V -In this step, you make the settings that are required for creating relationships.
    You can make the following settings:
    You can create new relationships.
    You can control the response of the system (error messages, warnings, information) if the 100% mark is exceeded in the case of "weighted" relationships.
    You can show or hide the weighting percentage of a relationship and, if required, define additional data for a relationship. You can specify, for example, in the view 'Additional relationship info' whether the recursiveness
    You can define the object types that are allowed for each relationship and inverse relationship.
    You can set up external relationships.
    External relationships are relationships between external object types i.e. object types that are not stored in the PLOG database in Personnel Development and Planning. (See also the step "Maintain object types").
    You can enter a time constraint for each relationship.
    You can change the "alias" name (semantic abbreviation) of a relationship.

  • Looking to purchase a new 13" MacBook Pro with 512GB SSD memory and 8GB ram.  Main purpose is to run Final Cut Prowithout being at my desk.  Is there's need to upgrade to the 16GB to make Final Cut Prorun more smoothly?

    I was planning on buying a new 13 inch MacBook Pro with 512 GB memory and 8GB RAM. The main purpose for this purchase Is to be able to run Final Cut Pro anywhere I want to. Should I upgrade to 16 GB of RAM with the added expense and wait time or is that overkill?

    8GB should be plenty  .  .  .  though as with most things in life, it all depends on exactly what you are doing. If you intend to edit long, highly complex projects loaded with effects and multicam clips you can't get enough RAM.
    For over 3 years, I and many others, have been  using 4GB with no problems.

  • What are the main differences between Signal Express and Labview?

    National Instruments provides a matrix so one can quickly compare the
    various versions of Labview but no comparison of Signal Express with
    Labview. Hence how does Signal Express compare with Labview? What
    are some of the things one can do with Labview one can't do with
    Signal Express?
    Howard

    hrh1818 wrote: Which version of Labview are you referring to? I don't consider the graphical version of Labview to be a full featured programming language. LabWindows/CVI is by a long shot a lot closer to being a full featured programming language than the graphical version of Labview.
    Howard,
    You clearly don't know what you are talking about. There is no "graphical version" of LabVIEW, there is just LabVIEW. Click on the article "Is LabVIEW a general purpose programming language?" written by the Jeff K. for some easy reading from a few years ago. It is all still true (except that object oriented features and recursion have been added in recent versions).
    One of the main points at this years NI-week was the discussion of how processor development is switching more and more to multicore designs  to improve performance because a simple boost in clock frequency is becoming more difficult. Linear, text based code is not well suited to take advantage of multticore design, while the dataflow based LabVIEW programming language automatically scales well to multiple processor cores, without any need to rewrite older code. I would say that only LabVIEW is futureproof in this respect. LabVIEW programmers are not wimps that are simply too stupid to write text based code. LabVIEW is not a toy language for people that don't want to learn a "real" programming language.
    LabVIEW is arguably the best programming language in terms of getting things done! I've never felt limited with LabVIEW and my programs often don't even have anything to do with data acquisition or instrument control. The difference between text based code vs. LabVIEW is like "DOS vs. Windows", "Radio vs. HD television". "Trilobyte vs. Homo sapiens" (sorry Putnam ). Text based code is monochrome, archaic and outdated and its linearity imposes unecessary constraints on the programmer that can only be (partially) overcome by wasting even more time throwing even more code at it.
    Sure, a seasoned text based programmer will initially have problems adapting to LabVIEW, just because you would need to adapt to and embrace the power of dataflow and not try to make a literal translation of the text code to LabVIEW, retaining old habits. If you get stuck, come back and ask here in the forum.
    You were looking for object oriented features and failed. All you need to do is a quick site search. All the information is out there. Just because you cannot find it in the first five sentences of the glossy brochure does not mean it does not exist. Maybe you want to read one of the application notes such as:
    LabVIEW Object-Oriented Programming: The Decisions Behind the Design
    In general, you should avoid judgement until you have all information. Your opinions seem quite biased and superficial and not really based on hard facts.
    Initially you asked about the difference between signal express and LabVIEW.
    hrh1818 wrote:
    > What kind of measurments do you want to do and what kind of requirements do you have?
    > You can also see for yourself and download evaluation version of both.
    No thanks, there has to be a better way to get an answer to my
    question than get involved in a two month study project.
    If you would answer the first question quoted above, we could certainly help you with the decision. Isn't that the main purpose of this thread?
    You can also contact your local LabVIEW Field Engineer to go over your requirements and help you make a decision. They usually know their stuff!
    Message Edited by altenbach on 09-02-2007 11:51 PM
    LabVIEW Champion . Do more with less code and in less time .

  • While defining a columnar table, what is the purpose of column store type

    Hi folks
    I have two questions related to columnar table definition.
    1. What is the purpose of column store type.
    While defining a columnar table, what is the purpose of column store type (STRING ,CS_FIXEDSTRING,CS_INT etc) , when I define a table using the UI I see that the column is showing STRING but when I goto EXPORT SQL it does not show.  Is this mandatory or optional ?
    2.VARCHAR Vs. CHAR - In the UI when I create the table I do not see the CHAR option , but I do see lot of discussion where people are using CHAR for defining the columnar table. Not sure why UI dropdown does not show it. I also read that we should avoid using VARCHAR as those columns are not compressed, is that true, I thought the column store gives compression for all the columns. Are there certain columns which cannot be compressed .
    Please let me know where I can find more information about these two questions.
    Poonam

    Hi Poonam
    the CS_-data types are the data types that are used internally in the column store. They can be supplied but it is not at all required or recommended to do so.
    SAP HANA will automatically use the correct CS_-data type for every SQL data type in your table definitions.
    To be very clear about this: don't use the CS_-data types directly. Just stick to the SQL data types.
    Concerning VARCHAR vs CHAR: fixed character data types are not supported anymore and don't show up anymore in the documentation.
    I have no idea why you believe that VARCHAR columns are not compressed but this is just a myth.
    create column table charcompr (fchar char(20), vchar varchar(20));
    insert into charcompr (
        select lpad ('x', to_int (rand()*20), 'y'), null from objects cross join objects);
    -- same data into both columns
    update charcompr set vchar = fchar;
    -- perform the delta merge and force a compression optimization
    merge delta of charcompr;
    update charcompr with parameters ('OPTIMIZE_COMPRESSION' ='FORCE');
    -- check the memory requirements
    select COLUMN_NAME, MEMORY_SIZE_IN_TOTAL, UNCOMPRESSED_SIZE, COUNT, DISTINCT_COUNT, COMPRESSION_TYPE
    from m_cs_columns where table_name ='CHARCOMPR'
    COLUMN_NAME    MEMORY_SIZE_IN_TOTAL    UNCOMPRESSED_SIZE   COUNT   DISTINCT_COUNT  COMPRESSION_TYPE
    FCHAR       3661                    70285738            6692569 20              RLE
    VCHAR       3661                    70285738            6692569 20              RLE
    We see: compression and memory requirements are the same for both fixed and variable character sizes.
    - Lars

  • What are the main tables using in vendor performance report.

    what are the main tables using in vendor performance report.
    how many select statements are in ABAP reports.

    Refer the links -
    vendor performance report !!!
    vendor performance report
    vendor performance report
    I need standard vendor performance report
    Regards,
    Amit
    Reward all helpful replies.

  • What is the purpose of Destination Function on Submit Button?(Doesn't work)

    Hi Gurus,
    There is a property "Destination Function" on Submit buttons.
    What is the purpose of this field.
    I tried setting some values here expecting following behavior in order:
    1. Process Form Request will get executed.
    2. User will be navigated to the OAF page related to the Destination Function.
    Destination Function property probably point to setInvokeFunction method of the OASubmitButtonBean.
    Please advise on this.
    Thanks and Regards,
    Prince

    Question 2. What is the purpose of View Instance on Submit Button? Is it there for BoundValues? Any examples how can we use this?
    Question 3. Related to Question 2, What is the purpose of View Instance and View Attribute on Button?

  • What is the purpose of open/close connection data socket?

    Hello everyone,
    I am writing and reading values in OPC Server through data socket. What is the purpose of open/close connection data socket when writing /reading a value?  Without the open/close connection element, it still work correctly. I am writing values in the server thru event stucture.I do not need any buffered reading or writing. What will happen if I didnt not use the open/close connection? Maybe it may cause some problems in my program which i didnt realise? 
    And I have attached an example of my program. Thanks
    Yehchia
    Attachments:
    Test Event.vi ‏11 KB

    Hi YehChia,
    I was talking about something like that:
    1. Not good. since with every iteration the DS connection needs to be opened and closed.
    2. Good. Since you open the connection only once then do the reads and close it afterwords.
    Christian

  • IPod Touch Newbie: What is the purpose of the iTunes app on my iPod Touch?

    What is the purpose of the iTunes app on my iPod Touch?
    All it does is connect to the iTunes store if I'm near a WiFi connection. It appears to be useful only for impulse purchasing of media. So why is it not named "iTunes Store"? It appears to have no other function.
    Also, to listen to my iTunes music on iPod Touch I have to click on the Music button...not the iTunes app. What logic is that?
    Also, iTunes has synced a movie for me, but I have no clue how to view it on the iPod Touch. It doesn't appear in iTunes on the iPod Touch, and there is no "Movie" button anywhere. What am I missing? I can't find it anywhere.

    For purchasing music, downloading podcasts,etc.
    http://manuals.info.apple.com/enUS/iPod_touch_3.1_UserGuide.pdf

Maybe you are looking for

  • Checking against Select-Options with "CP" using "IF value IN select_option"

    Dear experts, first of all: I'm sorry, if this question already should have been asked and answered! I tried quite a lot of search terms but didn't find anything helpful. We are using a statement like "IF value IN select_option" to perform comparison

  • How to batch change a date in aperture

    Is it possible to batch change a date in aperture the way I do it in iphoto (command option B)?  I dont want relative dates, I want a group of scanned pictures (negatives) to have the same date, but separated by one second.

  • Scanned documents do not print out correctly on forms.

    I scanned a pdf file to my computer.  I opened the pdf file on my computer using Adobe Reader.  I printed the file using my printer.  The pdf file did not print out correctly.  The printed text was out of alignment with the form I was printing on.  T

  • CFDOCUMENT PDF generation peformance on Linux running CF server 8 or 9 is horrible

    Can anyone help me understand how I can get the <cfdocument> tag to generate PDFs in reasonable time (and without throwing timeout errors) when running on CF 8 on Linux? Running on CF 9 doesn't make a difference, either. I can run the same code that

  • Flash Builder 4 - Mobile (Adobe read this!)

    This is the second time I've written this letter. The first was a five-paragraph rant detailing the chronicles of my journey into mobile using the Adobe tools. This time, however, I've decided to break it down in a different way. It goes like this: -