Workflow contidtion using boolean

I'm trying to create a send email workflow. My criteria is the activity type = Trip Report and a checkbox is checked. I but the expression below in my workflow expression but it fails the syntax check. Any ideas what I've got wrong?
FieldValue('<Type>') =LookupValue("TYPE", "Trip Report")
and [<IndexedBoolean0>]="T"
If I just put the first line in it works. So I must have something wrong with line two.
Any suggestions?
Thanks,
Sharon

Hi Sharon,
The lookup code for activity type is TODO_TYPE. You should also consider null values in expressions which is an important coding best practice because the Type field can be set to null. The checkbox also has a tristate value (null, Y and N). So your expression should be:
IfNull([<Type>], "Invalid") = LookupValue("TODO_TYPE", "Trip Report") AND IfNull([<IndexedBoolean0>], "N") = "Y"

Similar Messages

  • To use Boolean function in DECODE or CASE statement

    Hi all
    I have a scenario where i need to use a boolean function inside DECODE statement. When i tried this way iam getting "ORA-06553: PLS-382: expression is of wrong type".
    I doubt whether i can use boolean function inside DECODE or not?
    My query will be like this:
    select decode(my_fuction( ),'TRUE',1,'FALSE',0) from dual;
    Any help is highly appreciated.
    Thanks
    Sriram

    Overloaded functions must differ by more than their
    return type . At the time that the overloaded
    function is called, the compiler doesn't know what type
    of data that function will return. The compiler cannot,
    therefore, determine which version of the function to
    use if all the parameters are the same.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               

  • Can i use Boolean Expressions in Mail Rules?

    Can i use Boolean Expressions in Mail Rules?
    I need to create a rule to check whether a message contains BOTH a first and last name of EITHER of two people.
    For example, the rule im looking to create goes something like this:
    If ANY of the following conditions are met:
    message content - contains - john & doe
    message content - contains - jane & doe
    ive tried and cant seem to get it to work...
    Message was edited by: mysterioso

    AFAIK Mail rules do not support boolean expressions.
    to do what you want you'd have to create two rules
    rule 1
    if ALL of the following conditions are met
    message content - contains - john
    message content - contains - jdoe
    and similarly for rule 2.

  • How to use delay using boolean inputs

    dear sir
     I have created a AND logic where when both inputs are high using boolean switches output  should become high  green led should glow after 5seconds and other than it output should be false red led will glow. basically I want to use delay function .I am attaching file
    thanking you
    regards
    kn
    Solved!
    Go to Solution.
    Attachments:
    try1.vi ‏8 KB
    try.vi ‏38 KB

    kavharshre wrote:
    sir I am attaching the solution for boolean.Any improvements or suggestions.
    First of all, your front panel and diagram are way too big for this VI. Resize them to a reasonable size.
    As already mentioned, that "AND TRUE" is just silly.
    The upper boolean output of the inner loop is the same for both cases, thus it does not belong in the inner case structure at all.
    All you need is a single TRUE diagram constant. Configure the output tunnels to "use default if unwired".
    Try to keep your wires straight.
     Avoid crossing wires unless necessary
    Change the labels of your controls and indicators to something logical and intuitive. Self-documenting!
    Here's a literal rewrite.
    LabVIEW Champion . Do more with less code and in less time .
    Attachments:
    try3MOD.vi ‏8 KB

  • Workflow for using Sorenson Squeeze Compression Suite

    I am considering purchasing Sorenson Squeeze Compression Suite as I have noticed some unsatisfactory results in Compressor, even though I am generally impressed with Compressor and happy with the program and the options it gives, especially with exporting movie files for the web.
    Right Now, if I want to export my timeline to MPEG2, I either export directly to Compressor, or I will export to a Quicktime movie file, not self-contained, and then import that into compressor. The latter of the two is certainly a faster method but I have noticed quite a few mixed opinions on these forums as to whether you lose quality or not with that method because video is being "recompressed"
    Can anyone tell me the workflow when using Sorenson Squeeze Compression Suite? Will there be an option in FCP to export directly to Sorenson Squeeze as you do with Compressor, or will I have to export a Quicktime reference file and then import that into Squeeze? I noticed a few posts on this forum suggesting that you have to export a self-contained quicktime file for Sorenson Squeeze. How can that be good, as you would definitely be compressing the image more than once?
    Also, maybe this is a quesion for the DVDSP forum, but I was wondering what codec is used by DVDSP for encoding the menus. Does it use Compressor in the background? or something else? And if I am using Sorenson Squeeze, will DVDSP use Sorenson for encoding the menus, or will there even be an option to tell DVDSP to use Sorenson for encoding the menus?
    thanks for any input advice anyone can offer.

    thanks for that info. that is really good to know.
    the only thing is the box that says recompress all frames is shaded unless I check the box that says make movie self-contained. so, does that mean anything? does that mean that it will only recompress frams if you make the movie self-contained? and will never recompress if you just export a reference file?
    thanks.

  • Hi i want to use boolean type in a procedure as out parameter !!

    Hi
    I need to use Boolean type as out parameter in my procedure which return true if the SELECT query in procedure returns any row otherwise it should return false
    please HELP !!

    I need to use Boolean type as out parameter in my procedure which return true if the SELECT query in procedure returns any row otherwise it should return false
    Sounds like basic PL/SQL stuff.
    What problem are you experiencing?
    Are you looking for something like this?
    create or replace procedure check_emp (p_empno in number, p_result out boolean) is
      dummy  pls_integer;
    begin
      select 1
      into dummy
      from scott.emp
      where empno = p_empno;
      p_result := true;
    exception
      when no_data_found then
        p_result := false;
    end;
    SQL> declare
      2    emp_exists  boolean;
      3  begin
      4    check_emp(7839, emp_exists);
      5    if emp_exists then
      6      dbms_output.put_line('Employee exists');
      7    else
      8      dbms_output.put_line('Employee does not exist');
      9    end if;
    10  end;
    11  /
    Employee exists
    PL/SQL procedure successfully completed

  • How to use boolean operator to get count

    Hi All,
    In my query i need to add a field Count which shows number.
    Meaning,
    Column A   ColumnB ColumnC  Count
    100               50            0            2
    55                60             76         3
    79                0               0           1
    meaning from all three column only two has values then Count should show 2. etc....
    any suggestion how to use boolean expression here ?
    or anyother way to display Count ?
    thanks,
    KS

    Hi thanks for idea.
    boolean didnt work here. the formulau sugested worked...
    But i wrote formula for the Count --> COUNT("overtime") and for the Count property I selected Calculate Result As --> Summation fo Rounded Values
    so the output is as follows:
    i had data for 3 payperiods
    Count  (1st 3 columns)                    overall result(last Column)
    200801     200802     200803           
    1                 0             1                         2
    1                1              1                         3
    0                1             0                         1
    Now the out put i wanted is in the last column -Result column.
    I dont want Count column to be display like this. it is showing values instead of total. any this i should change for this?
    thanks,
    KS

  • Is it possible to use booleans to build a VI that uses buttons to switch between screens (3 only) while the other screens disappear?

    As a beginner, I need help figuring out how to build a simply VI that uses boolean logic to switch between three different screens. I need a "Home" screen, the next screen which has a button to go back "Home" and a third screen which has two buttons to go "Home" and "Previous Screen". Can someone help me with a simple block diagram?

    Hi,
    Or put the data in three tab controls. The tabs itself are hidden. The
    program switches between the tab sheet if one of the buttons is pressed.
    The buttons are best not copied, e.g. the same buttons are used in every tab
    sheet (buttons hover above the tab, a black shadow will apear). If the first
    sheet is shown, button 2 and 3 are hidden, sheet two: only button 3 is
    hidden, sheet three no button is hidden.
    Showing the tabs allows the user to choose the views directlly. The button
    logic is not needed anymore. But you'll have to live with a simple tab
    sheet, instead of a fancy button system!
    Regards,
    Wiebe.
    "Jason R" wrote in message
    news:[email protected]...
    > Another solution if you want to avoid property-node hell...
    >
    > Divide your screen into 1/4ths. That is, make your FP 4x larger than
    > your desktop.
    >
    > Place screen 1 on the upper left quadrant.
    > Place screen 2 on the upper right quadrant.
    > Place screen 3 on the lower left quadrant.
    > Screen 4 (lower right quadrant) is unused.
    >
    > Disable the ability to scroll at run time.
    >
    > As the user clicks buttons, use the properties of this vi to move what
    > the user can see on the front panel.
    >
    > Cheating? yep. Easier? yep.
    >
    > Hope this helps! =)
    >
    > btw - be sure not to update the FP controls when they are not visible,
    > or this will eat processor cycles.
    >
    > Sincerely,
    > Jason G Richmond
    > Project Engineer II and LVAAD Instructor
    > VI Engineering
    > [email protected] (domain should be vieng.com (no A's))
    >
    >
    > missileman wrote:
    > > Is it possible to use booleans to build a VI that uses buttons to
    > > switch between screens (3 only) while the other screens disappear?
    > >
    > > As a beginner, I need help figuring out how to build a simply VI that
    > > uses boolean logic to switch between three different screens. I need a
    > > "Home" screen, the next screen which has a button to go back "Home"
    > > and a third screen which has two buttons to go "Home" and "Previous
    > > Screen". Can someone help me with a simple block diagram?
    >
    >

  • Can we use Boolean or Validations in HFM Rules

    Hi Gurus
    Can we use Boolean or Validations for input cells in HFM?
    Example:
    1. I want to restrict the user to enter only single digit (0 or 1 are valid) in to a cell for a special purpose. (in smartview or webform)
    2. I want to restrict the user to enter only single Character (Y or N are valid) in to a cell for a special purpose.(in smartview or webform)
    After submitting the data, If the data does not matches to the given condition it has to through an Error message or validation message to the end user.
    Can we write these kind of rules in HFM?
    Regards
    Smilee

    Hi Smilee,
    HFM's model of validation and error checking is not as you describe. Data cannot be validated at the form/data-entry level. Instead, HFM's validation model goes like this:
    1. You must provide with a validation account for each validation you need, with a common parent usually declared in the validation accounts in the ApplicationSettings. A zero (or within tolerance limits) in the validation account means correct, any other value means error.
    2. You must write a normal calculation rule, which checks the user's input for valid data entry and place a zero or other value to the validation account.
    3. The user inputs her values (via form, or data load, FDM, SmartView etc.), saves her data and calculates.
    4. As soon as all the validation calculations write zeros to the to validation account during calculations, the user can submit successfully (submission is part of process management). However, if any of the validations fail (meaning non zero value to the top validation account) the user cannot submit until she corrects the error value. Errors can be traced easily, judging by the exact validation account which fails.
    Another observation regarding your point 2 is that only numeric values can be written in HFM cells, no alphabetic characters are allowed. You should replace Y/N logic to 0/1.
    Regards,
    Kostas

  • Install workflow manager using DSC powershell

    Hi,
    i am trying to install workflow manager using DSC powershell.
    I am using WebpiCmd.exe to install it.
    Below is the DSC powershell script
    configuration C_WFMgr
        Node $AllNodes.NodeName
            Script WF_Install
                GetScript = { @{ Name = "WF_Install" } }
                TestScript = {                
                    $false
                SetScript =
                $currentPrincipal = New-Object Security.Principal.WindowsPrincipal( [Security.Principal.WindowsIdentity]::GetCurrent() )
                if ($currentPrincipal.IsInRole( [Security.Principal.WindowsBuiltInRole]::Administrator ) -eq $false) {
                (get-host).UI.RawUI.Backgroundcolor="DarkRed"                                   
                    write-Verbose "Warning: PowerShell is not running as an Administrator.`n"  
                    exit 
                 else
                    #set-executionpolicy "Execution user account"
                    write-Verbose $currentPrincipal.Identity.Name
                    write-Verbose "Warning: PowerShell is running as an Administrator.`n"                
                    Write-Verbose "Workflow Manager installation started.."
                    $cmd = "& 'C:\WorkflowManagerFiles\bin\WebpiCmd.exe' /Install /Products:WorkflowManager /XML:c:/WorkflowManagerFiles/feeds/latest/webproductlist.xml /log:C:/Users/backup/t1.txt
    /AcceptEula"
                    Invoke-Expression $cmd | Write-Verbose                             
    Below is the error message
    Started downloading products...
     Started installing Products...
     Started installing: 'Execute ASP.NET IIS Registration tool
     Started downloading: 'Workflow Manager Client 1.0 Refresh'
     Downloaded: 'Workflow Manager Client 1.0 Refresh'
     Started downloading: 'Service Bus 1.0'
     Downloaded: 'Service Bus 1.0'
     Started downloading: 'Workflow Manager 1.0'
     Downloaded: 'Workflow Manager 1.0'
     Install completed (Success): 'Execute ASP.NET IIS Registra
    tion tool'
     Execute ASP.NET IIS Registration tool : Installed
     Started installing: 'Workflow Manager Client 1.0 Refresh'
     Install completed (Failure): 'Workflow Manager Client 1.0
    Refresh'
     WorkflowClient : Failed.
     Error opening installation log file. Verify that the speci
    fied log file location exists and is writable.
     Started installing: 'Service Bus 1.0'
     Install completed (Failure): 'Service Bus 1.0'
     ServiceBus : Failed.
     Error opening installation log file. Verify that the speci
    fied log file location exists and is writable.
     DependencyFailed: Workflow Manager 1.0
     Verifying successful installation...
     Execute ASP.NET IIS Registration tool              True
     Workflow Manager Client 1.0 Refresh                False
         Log Location: C:\Windows\system32\config\systemprofile
    \AppData\Local\Microsoft\Web Platform Installer\logs\install\2015-01-02T14.58.57\WorkflowManagerClient_x64.txt
     Service Bus 1.0                                    False
         Log Location: C:\Windows\system32\config\systemprofile
    \AppData\Local\Microsoft\Web Platform Installer\logs\install\2015-01-02T14.58.57\Service_Bus.txt
     Workflow Manager 1.0                               False
     Install of Products: FAILURE

    I am pretty sure that DSC requires WFM.  If  I am right then WFM is in use and cannot be replaced unless you specify another logfile location.  Look at the DSC and see how to specify a new log location that can be used for the install. 
    If the MSU is built correctly then you will require a reboot to update the install.
    Try just doing WFM alone until you work it out.
    I also recommend posting in the Management forum for any other issues that might be known.
    Management
    DSC is a work in progress so many things have to be worked out as you need them.  Be sure to get the latest kits.  I think we are at Wave 9 now.
    PowerShell
    DSC Resource Kit Wave 9
    ¯\_(ツ)_/¯

  • Install workflow manager using DSC declarative configuration

    I am trying to install workflow manager using below DSC powershell script.
    Configuration
    C_Pkg_WFInstall
    Node $AllNodes.NodeName
    Package C_Pkg_WFInstall
    Ensure = "Present"
    Name = "Workflow Manager Client 1.0"
    Path = "C:\WorkflowManagerFiles\bin\WebpiCmd.exe"
    Arguments =
    "/Install /Products:'Workflow Manager Client 1.0' /XML:'c:/WorkflowManagerFiles/feeds/latest/webproductlist.xml' /log:'c:/users/backup/workflow.txt' /AcceptEula"
    ProductId =
    "A5ABAF5F-B5B6-44B3-B69F-2E13DC60FC9F"
    $ConfigData
    = @{
    AllNodes = @(
        NodeName =
    "CHN-AERO-VM28";         
    C_Pkg_WFInstall
    -ConfigurationData
    $ConfigData –Verbose
    Start-DscConfiguration
    -Wait -force
    -Verbose -Path
    .\C_Pkg_WFInstall
    And i get the below error
    PowerShell provider MSFT_PackageResource 
    failed to execute Set-TargetResource functionality with error message: The return code -1 was not expected. Configuration is likely not
    correct
    + CategoryInfo         
    : InvalidOperation: (:) [], CimException
    + FullyQualifiedErrorId : ProviderOperationExecutionFailure
    But while installing from command prompt window i could install the below list successfully
    IdentifyingNumber : {A5ABAF5F-B5B6-44B3-B69F-2E13DC60FC9F}
    Name              : Workflow Manager Client 1.0
    IdentifyingNumber : {04A7199E-565D-4654-88A3-80A9A7BADDD9}
    Name              : Workflow Manager 1.0
    IdentifyingNumber : {F438C511-5A64-433E-97EC-5E5343DA670A}
    Name              : Service Bus 1.0
    I tried with all the above 3 product ids, its not working.

    Thanks for your reply.
    I get the below error in eventviewer - Applications and Services Log - Windows Powershell
    The description for Event ID 600 from source PowerShell cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the
    local computer.
    If the event originated on another computer, the display information had to be saved with the event.
    The following information was included with the event:
    Alias
    Started
     ProviderName=Alias
     NewProviderState=Started
     SequenceNumber=1
     HostName=Default Host
     HostVersion=4.0
     HostId=979b4813-7bd4-47d7-9729-4166ae91e9c1
    The handle is invalid
    Log Name : Windows PowerShell
    Source : PowerShell (PowerShell)
    Event ID : 600
    Task Category : Provider Lifecycle
    I got the same error message in subsequent logs but the providername is different as below
     ProviderName=Environment 
     ProviderName=FileSystem  
     ProviderName=Function  
     ProviderName=Registry 
     ProviderName=Variable
    The description for Event ID 400 from source PowerShell cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local
    computer.
    If the event originated on another computer, the display information had to be saved with the event.
    The following information was included with the event:
    Available
    None
     NewEngineState=Available
     PreviousEngineState=None
     SequenceNumber=13
     HostName=Default Host
     HostVersion=4.0
     HostId=979b4813-7bd4-47d7-9729-4166ae91e9c1
     EngineVersion=4.0
     RunspaceId=6374c946-1219-4870-bc51-528faae9671d
    Log Name : Windows PowerShell
    Source : PowerShell (PowerShell)
    Event ID : 400
    Task Category : Engine Lifecycle
    But i believe the problem is with either the product name or product id, since it installs three products on one invoke, i dont know which product id we need to give. i tried with all the above 3 product ids. Its not working.
    I think by default DSC powershell runs under system account "NT AUTHORITY\SYSTEM".

  • How to use boolean?

    I now boolean is a data type that returns either true or false but i dont really know how to use it. Can someone please explain it for me with some common examples or codes would be highly appreaciated?
    One more question, how do you use boolean isDigit(char ch) or boolean isLetter(char ch)?
    Thanks

    public static jePrastevilo(int number){
    for(int
    int deljitelj=2;deljitelj<number;deljitelj++){
                        if(number%deljitelj==0)
                             return false;
                        else return true;
    Why this doesn't work? Retun type required?You need to make sure that the method declares that it is returning a boolean.
    i.e. public static boolean jePrastevilo(int number)
    Also think about what happens when number is less than 2?

  • Restart project server workflow programmatically using psi 2010

    hi sir,
         I am working on project server 2010. I  want restart project server workflow using PSI. please suggest me
    vijay

    Hi,
    I think this might help:
    http://epmxperts.wordpress.com/2012/05/27/change-workflow-stage-using-psi-wcf/
    Paul

  • Cannot use BOOLEAN in Oracle

    Why we can't use BOOLEAN in SQL statement but we can use it in PL/SQL statement. But what does that mean? Thanks.

    grus wrote:
    Why we can't use BOOLEAN in SQL statement but we can use it in PL/SQL statement. But what does that mean? Thanks.As already explained, SQL and PL (Programming Logic) are different computer languages and have different data types. Though PL typically supports most SQL data types too.
    Oracle however allows you to define your own SQL data types - and create these in a similar way as you would define an object orientated class. These data types have constructors, properties and methods, static class methods - and supports abstract definitions and inheritance. All the basics of an o-o class definition is supported.
    This allows you to, for example, create your own boolean data type that you can use in both SQL and PL. Not that this is specifically a good idea for boolean values (as a single character column with a Y/N constraint can do the job equally well to). But even so, to define your own data types is a very powerful feature that can be used to deal with non-common data types in specialised database implementations.
    An example of how to create a SQL boolean type was posted some time ago in [this thread|http://forums.oracle.com/forums/thread.jspa?messageID=2116991#2116991].

  • Example workflow scenario using webflowconnector

    Hi all,,
    I have many queries related to implementation of workflow in UWL.
    I have read online help and blogs
    The part of configuring the UWL in the intial go is well understood
    I wanna implement a sample workflow scenario in UWL
    - for this i need to configure the UWL in my EP portal ,,which i did using workflowconnector
    - But i wanna knw from where the workitems .The table rows(records created) is accumulated ,,eg in tasks..
    Is the data should (sample records /tasks)be populated in the backend itself or from the portal i can create.....
    I dont have any ABAP knowledge to work at the Backend R/3,,how to fill it there
    any other way which is available
    I need sample tasks/records to be filled in the UWL iview under tasks.notifications etc how can i fill?
    I request you to give me sample simple  scenario  with all the steps
    may be between two users (like approver....employee)
    I need it badly at the earliest..help me experts..pts will be rewarded as per norm.
    Thanks
    Swathi

    Ok,,
    i shall try to put in this way,,
    ok taking the scenario of  ESS ..,
    what are the settings u do ,,,with which the manager and employee is identified by the ESS..
    without ESS cant i implement a workflow scenario using webflowconnector in my UWL iview...
    IF i could,,then after configuration i get a blank iview with tabs--tasks/alerts/notifications
    Now ,,hw should a  i put the single task(u can call record in this table)
    for eg
    subject                                      priority  Absencefrom     AbsenceTo
    approve absence of swathi           High     March7             March11
    from wher does the table data come from?
    Wher u mention who is approver ,who is employee?
    Hope it made sense
    Swathi

Maybe you are looking for

  • How to implement the RemoveLast function in a link list? check my code plz

    Hi guys, How to delete the last element in a user defined linklist. I am using the following code to find the last element of the list. It works fine, but i don't know how to remove that element ... public Object getRear()                rear=front;

  • Dependent reservation created instead of planned order

    Hello Experts, After MRP run for some material only dependent reservation created instead of planned order? What would be the problem?

  • Can WLC create EoIP tunnels to more than one Anchor Controllers

    Hello, Is it possible to create EoIP tunnels to two different Anchor Controllers on two different DMZs from a single WLC. So we can tunnel the traffics of two SSIDs to different DMZ environments. Anchor Controllers can create 71 connections to Foreig

  • Fireworks CS6 Internal Error, other components APPCRASH

    Hello, I have tried installing this CS6 Web Premium for the past month on my corporate machine. My local IT has re-imaged and even replaced my hard drive a number of times with fresh CS6 installs right after. 32 & 64 bit. Currently I am on a new hard

  • Error in Bapi : BAPI_ACC_INVOICE_RECEIPT_POST

    Hi Experts,                 Iam using bapi " BAPI_ACC_INVOICE_RECEIPT_POST " to post outgoing payments ( tcode F-53 ). I have passed all the values to the bapi structures. It is giving the error saying -- " Required field DOC_TYPE was not transferred